1
|
Wu K, Pang L, Su P, Lv C. Association between metallic implants and stroke in US adults from NHANES 2015-2023 a cross-sectional study. Front Aging Neurosci 2024; 16:1505645. [PMID: 39759400 PMCID: PMC11695404 DOI: 10.3389/fnagi.2024.1505645] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Accepted: 12/10/2024] [Indexed: 01/07/2025] Open
Abstract
Objective Metal implants play a vital role in orthopedic treatment and are widely used in fracture repair, joint replacement and spinal surgery. Although these implants often contain key elements such as chromium (Cr), their potential health effects, particularly their association with stroke risk, have not been fully elucidated. This study aimed to evaluate the association between metallic implants and stroke. Methods Using data from the 2015 to 2023 National Health and Nutrition Examination Survey (NHANES), we conducted a cross-sectional analysis of 12,337 US adults, in which 3,699 participants reported having metal implants and 8,638 without. Implant-like. Results Through logistic regression analysis, we revealed a significant positive association between metallic implants and stroke risk (adjusted OR = 1.458, 95%CI (1.130, 1.881), p = 0.004). Further stratified analysis found that this positive association was more significant among older and less physically active participants. Conclusion Findings suggest that metallic implants may be associated with an increased risk of stroke, but given the inherent limitations of cross-sectional studies, this study cannot establish causality.
Collapse
Affiliation(s)
- Kai Wu
- Wenzhou TCM Hospital of Zhejiang Chinese Medical University, Wenzhou, China
| | - Liang Pang
- Wenzhou TCM Hospital of Zhejiang Chinese Medical University, Wenzhou, China
| | - Pingping Su
- Wenzhou TCM Hospital of Zhejiang Chinese Medical University, Wenzhou, China
| | - Cunxian Lv
- Wenzhou TCM Hospital of Zhejiang Chinese Medical University, Wenzhou, China
| |
Collapse
|
2
|
Brennan PC, Peterson SM, O'Byrne TJ, Laporta ML, Wyles CC, Jannetto PJ, Kane GC, Vassilaki M, Maradit Kremers H. Blood metal concentrations and cardiac structure and function in total joint arthroplasty patients. World J Orthop 2024; 15:773-782. [PMID: 39165877 PMCID: PMC11331322 DOI: 10.5312/wjo.v15.i8.773] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 07/19/2024] [Accepted: 07/29/2024] [Indexed: 08/13/2024] Open
Abstract
BACKGROUND There is concern regarding potential long-term cardiotoxicity with systemic distribution of metals in total joint arthroplasty (TJA) patients. AIM To determine the association of commonly used implant metals with echocardiographic measures in TJA patients. METHODS The study comprised 110 TJA patients who had a recent history of high chromium, cobalt or titanium concentrations. Patients underwent two-dimensional, three-dimensional, Doppler and speckle-strain transthoracic echocardiography and a blood draw to measure metal concentrations. Age and sex-adjusted linear and logistic regression models were used to examine the association of metal concentrations (exposure) with echocardiographic measures (outcome). RESULTS Higher cobalt concentrations were associated with increased left ventricular end-diastolic volume (estimate 5.09; 95%CI: 0.02-10.17) as well as left atrial and right ventricular dilation, particularly in men but no changes in cardiac function. Higher titanium concentrations were associated with a reduction in left ventricle global longitudinal strain (estimate 0.38; 95%CI: 0.70 to 0.06) and cardiac index (estimate 0.08; 95%CI, -0.15 to -0.01). CONCLUSION Elevated cobalt and titanium concentrations may be associated with structural and functional cardiac changes in some patients. Longitudinal studies are warranted to better understand the systemic effects of metals in TJA patients.
Collapse
Affiliation(s)
- Peter C Brennan
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, United States
| | - Stephanie M Peterson
- Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, United States
| | - Thomas J O'Byrne
- Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, United States
| | - Mariana L Laporta
- Department of Anesthesiology and Perioperative Medicine, Mayo Clinic, Rochester, MN 55905, United States
| | - Cody C Wyles
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN 55905, United States
| | - Paul J Jannetto
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN 55905, United States
| | - Garvan C Kane
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, United States
| | - Maria Vassilaki
- Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, United States
| | - Hilal Maradit Kremers
- Department of Quantitative Health Sciences, Mayo Clinic, Rochester, MN 55905, United States
| |
Collapse
|
3
|
Jenkinson MRJ, Meek DRM, Tate R, Brady A, MacMillan S, Grant H, Currie S. Cardiac function may be compromised in patients with elevated blood cobalt levels secondary to metal-on-metal hip implants. Bone Joint J 2024; 106-B:51-58. [PMID: 38423080 DOI: 10.1302/0301-620x.106b3.bjj-2023-0814.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
Aims Elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties are a suggested risk factor for developing cardiovascular complications including cardiomyopathy. Clinical studies assessing patients with MoM hips using left ventricular ejection fraction (LVEF) have found conflicting evidence of cobalt-induced cardiomyopathy. Global longitudinal strain (GLS) is an echocardiography measurement known to be more sensitive than LVEF when diagnosing early cardiomyopathies. The extent of cardiovascular injury, as measured by GLS, in patients with elevated blood cobalt levels has not previously been examined. Methods A total of 16 patients with documented blood cobalt ion levels above 13 µg/l (13 ppb, 221 nmol/l) were identified from a regional arthroplasty database. They were matched with eight patients awaiting hip arthroplasty. All patients underwent echocardiography, including GLS, investigating potential signs of cardiomyopathy. Results Patients with MoM hip arthroplasties had a mean blood cobalt level of 29 µg/l (495 nmol/l) compared to 0.01 µg/l (0.2 nmol/l) in the control group. GLS readings were available for seven of the MoM cohort, and were significantly lower when compared with controls (-15.5% vs -18% (MoM vs control); p = 0.025)). Pearson correlation demonstrated that GLS significantly correlated with blood cobalt level (r = 0.8521; p < 0.001). However, there were no differences or correlations for other echocardiography measurements, including LVEF (64.3% vs 63.7% (MoM vs control); p = 0.845). Conclusion This study supports the hypothesis that patients with elevated blood cobalt levels above 13 µg/l in the presence of a MoM hip implant may have impaired cardiac function compared to a control group of patients awaiting hip arthroplasty. It is the first study to use the more sensitive parameter of GLS to assess for any cardiac contractile dysfunction in patients with a MoM hip implant and a normal LVEF. Larger studies should be performed to determine the potential of GLS as a predictor of cardiac complications in patients with MoM arthroplasties.
Collapse
Affiliation(s)
| | | | - Rothwelle Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | - Adrian Brady
- Glasgow Royal Infirmary, Glasgow, UK
- University of Glasgow, Glasgow, UK
| | | | - Helen Grant
- Department of Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| |
Collapse
|
4
|
Høl PJ, Hallan G, Furnes O, Fenstad AM, Indrekvam K, Kadar T. Similarly low blood metal ion levels at 10-years follow-up of total hip arthroplasties with Oxinium, CoCrMo, and stainless steel femoral heads. Data from a randomized clinical trial. J Biomed Mater Res B Appl Biomater 2023; 111:821-828. [PMID: 36356214 PMCID: PMC10099800 DOI: 10.1002/jbm.b.35193] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2022] [Revised: 09/21/2022] [Accepted: 10/29/2022] [Indexed: 11/12/2022]
Abstract
The use of inert head materials such as ceramic heads has been proposed as a method of reducing wear and corrosion products from the articulating surfaces in total hip arthroplasty, as well as from the stem-head taper connection. The aim of the present study was to compare the blood metal ion levels in patients with Oxinium and CoCrMo modular femoral heads, as well as monoblock stainless steel Charnley prostheses at 10 years postoperatively. The 150 patients with osteoarthritis of the hip joint included in a randomized clinical trial were grouped according to femoral head material. One group (n = 30) had received the Charnley monoblock stainless steel stem (DePuy, UK). The other patients (n = 120) received a Spectron EF CoCrMo stem with either a 28 mm CoCrMo or Oxinium modular head (Smith & Nephew, USA). After 10 years, 38 patients had withdrawn, 19 deceased, 7 revised due to aseptic loosening and 5 revised due to infection. The 81 patients with median age of 79 years (70-91) were available for whole blood metal ion analysis. The levels of Co, Cr, Ni and Zr in the blood were generally low with all the head materials (medians <0.3 micrograms/L) and no statistical difference between the groups were found (p = .2-.8). Based on the low blood metal ion values in our study groups, no indication of severe trunnion corrosion in patients with CoCrMo heads was observed, neither was there any beneficial reduction in metal ion exposure with the Oxinium femoral heads.
Collapse
Affiliation(s)
- Paul Johan Høl
- Biomatlab, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,Department of Clinical Medicine, University of Bergen, Bergen, Norway
| | - Geir Hallan
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway.,The Coastal Hospital at Hagevik, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Ove Furnes
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Anne Marie Fenstad
- The Norwegian Arthroplasty Register, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Kari Indrekvam
- Department of Clinical Medicine, University of Bergen, Bergen, Norway.,The Coastal Hospital at Hagevik, Department of Orthopedic Surgery, Haukeland University Hospital, Bergen, Norway
| | - Thomas Kadar
- Physical Medicine and Rehabilitation, Clinic of Habilitation and Rehabilitation, Haukeland University Hospital, Bergen, Norway
| |
Collapse
|
5
|
Tomášek A, Maňoušek J, Kuta J, Hlásenský J, Křen L, Šindler M, Zelený M, Kala P, Němec P. Metals and Trace Elements in Calcified Valves in Patients with Acquired Severe Aortic Valve Stenosis: Is There a Connection with the Degeneration Process? J Pers Med 2023; 13:jpm13020320. [PMID: 36836554 PMCID: PMC9967375 DOI: 10.3390/jpm13020320] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2022] [Revised: 01/30/2023] [Accepted: 02/07/2023] [Indexed: 02/16/2023] Open
Abstract
BACKGROUND Acquired calcified aortic valve stenosis is the most common valve disease in adulthood. In the etiopathogenesis of this complex pathology, the importance of inflammation is mentioned, in which non-infectious influences represented by the biological effects of metal pollutants may participate. The main goal of the study was to determine the concentration of 21 metals and trace elements-aluminium (Al), barium (Ba), cadmium (Cd), calcium (Ca), chrome (Cr), cobalt (Co), copper (Cu), gold (Au), lead (Pb), magnesium (Mg), mercury (Hg), molybdenum (Mo), nickel (Ni), phosphorus (P), selenium (Se), strontium (Sr), sulfur (S), tin (Sn), titanium (Ti), vanadium (V) and zinc (Zn)-in the tissue of calcified aortic valves and to compare them with the concentrations of the same elements in the tissue of healthy aortic valves in the control group. MATERIAL AND METHODS The study group consisted of 49 patients (25 men, mean age: 74) with acquired, severe, calcified aortic valve stenosis with indicated heart surgery. The control group included 34 deceased (20 men, median age: 53) with no evidence of heart disease. Calcified valves were explanted during cardiac surgery and deep frozen. Similarly, the valves of the control group were removed. All valves were lyophilized and analyzed by inductively coupled plasma mass spectrometry. The concentrations of selected elements were compared by means of standard statistical methods. RESULTS Calcified aortic valves contained significantly higher (p < 0.05) concentrations of Ba, Ca, Co, Cr, Mg, P, Pb, Se, Sn, Sr and Zn and-in contrast-lower concentrations of Cd, Cu, Mo, S and V than valves of the control group. Significant positive correlations of concentrations between the pairs Ca-P, Cu-S and Se-S and strong negative correlations between the elements Mg-Se, P-S and Ca-S were found in the affected valves. CONCLUSION Aortic valve calcification is associated with increased tissue accumulation of the majority of the analyzed elements, including metal pollutants. Some exposure factors may increase their accumulation in the valve tissue. A relationship between exposure to environmental burden and the aortic valve calcification process cannot be ruled out. Advances in histochemical and imaging techniques allowing imaging of metal pollutants directly in valve tissue may represent an important future perspective.
Collapse
Affiliation(s)
- Aleš Tomášek
- Centre for Cardiovascular Surgery and Transplantation, Pekařská 53, 656 91 Brno, Czech Republic
| | - Jan Maňoušek
- Department of Internal Cardiology Medicine, University Hospital and Faculty of Medicine, Masaryk University, Jihlavská 20, 625 00 Brno, Czech Republic
| | - Jan Kuta
- Research Centre for Toxic Compounds in the Environment (RECETOX), Faculty of Science, Masaryk University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Jiří Hlásenský
- Department of Internal Cardiology Medicine, University Hospital and Faculty of Medicine, Masaryk University, Jihlavská 20, 625 00 Brno, Czech Republic
- Correspondence: ; Tel.: +420-532-232-454
| | - Leoš Křen
- Institute of Pathology, University Hospital and Faculty of Medicine, Masaryk University, Jihlavská 20, 625 00 Brno, Czech Republic
| | - Martin Šindler
- Institute of Forensic Medicine, St Anne’s University Hospital and Faculty of Medicine, Masaryk University, Tvrdého 2a, 662 99 Brno, Czech Republic
| | - Michal Zelený
- Institute of Forensic Medicine, St Anne’s University Hospital and Faculty of Medicine, Masaryk University, Tvrdého 2a, 662 99 Brno, Czech Republic
| | - Petr Kala
- Department of Internal Cardiology Medicine, University Hospital and Faculty of Medicine, Masaryk University, Jihlavská 20, 625 00 Brno, Czech Republic
| | - Petr Němec
- Centre for Cardiovascular Surgery and Transplantation, Pekařská 53, 656 91 Brno, Czech Republic
| |
Collapse
|
6
|
Abdel Hamid OI, Attia ME, Hirshon JM, El-Shinawi M, El-Hussaini M, El-Setouhy M. Psychiatric Disorders and Genotoxicity Following Primary Metal on Polyethylene Total Hip Arthroplasty and Their Correlation to Cobalt/Chromium Levels. Drug Healthc Patient Saf 2022; 14:97-111. [PMID: 35880007 PMCID: PMC9308046 DOI: 10.2147/dhps.s360643] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2022] [Accepted: 07/04/2022] [Indexed: 11/23/2022] Open
Abstract
Introduction Hip arthroplasty (HA) using implantable metal components is among the commonest orthopedic interventions. However, it can be followed by several complications following corrosion and the release of metal ions. Several studies proved that damaged genomic DNA may contribute to the pathophysiology of mental disorders. Aim The current work aims to evaluate the psychiatric disorders in metal on polyethylene hip arthroplasty (MOP-HA) patients and its correlation to cobalt/chromium (Co/Cr) levels and genotoxicity. Methods The work was a longitudinal follow-up study including 34 adults with unilateral primary MOP-HA meeting the inclusion and exclusion criteria. Preoperatively, 6, 12-months-postoperatively, patients were examined for cognitive impairment using mini-mental-state-examination (MMSE), depression using major-depressive-inventory (MDI), and blood samples were collected for estimation of Co/Cr, detection of genotoxicity by single-cell-gel-electrophoresis (comet assay) and serum 8-hydroxy-2'-deoxyguanosine (8-OHdG). Results Cognitive impairment was reported in 18.5% and 14.8% at 6-months, and 12-months postoperative, respectively. Depressive disorder was recorded in 22.2% at 6-months and 14.8% at 12-months postoperative. The marginal homogeneity tests proved a non-significant difference. There was a non-significant difference in preoperative, 6-months, 12-months postoperative MMSE, and MDI scores. There were significantly increased Co/Cr levels at 6-months postoperative. The levels decreased at 12-months postoperative, however, still significantly higher than preoperative values. There was a significant increase in serum 8-OHdG and the levels were positively correlated to cobalt levels at both 6 and 12-months-postoperative. There was a non-significant difference among preoperative, 6-months, and 12-months postoperative comet assay measurements. Conclusion From previous findings, we can conclude that will-functioning MOP hip arthroplasty can induce increased ion levels and positively correlated increase in biochemical markers of genotoxicity (8-OHdG).
Collapse
Affiliation(s)
- Omaima I Abdel Hamid
- Forensic Medicine and Clinical Toxicology Department, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Mohamed E Attia
- Orthopedics Departments, Faculty of Medicine, Zagazig University, Zagazig, Egypt
| | - Jon M Hirshon
- Department of Emergency Medicine, University of Maryland, School of Medicine, Baltimore, MD, USA
- Department of Epidemiology and Public Health, University of Maryland, School of Medicine, Baltimore, MD, USA
| | - Mohamed El-Shinawi
- Department of General Surgery, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Galala University, Galala City, Suez, Egypt
| | - Moustafa El-Hussaini
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
| | - Maged El-Setouhy
- Department of Community, Environmental and Occupational Medicine, Faculty of Medicine, Ain Shams University, Cairo, Egypt
- Department of Family and Community Medicine, Faculty of Medince, Jazan University, Jazan, Kingdom of Saudi Arabia
| |
Collapse
|
7
|
Deere K, Matharu GS, Ben-Shlomo Y, Wilkinson JM, Blom AW, Sayers A, Whitehouse MR. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants : an analysis of the National Joint Registry. Bone Joint J 2022; 104-B:359-367. [PMID: 35227088 DOI: 10.1302/0301-620x.104b3.bjj-2021-0397.r1] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
AIMS A recent report from France suggested an association between the use of cobalt-chrome (CoCr) femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. CoCr is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint arthroplasties and other orthopaedic procedures in which CoCr is used annually. We examined whether CoCr-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years' follow-up. We excluded any patients with bilateral THAs, knee arthroplasties, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing CoCr or not containing CoCr. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS There were 158,677 individuals (42.4%) with an implant containing CoCr. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association between patients with CoCr implants and higher rates of any of the outcomes. CONCLUSION CoCr-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer, or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of CoCr-containing implants is not associated with significant adverse systemic effects. Cite this article: Bone Joint J 2022;104-B(3):359-367.
Collapse
Affiliation(s)
- Kevin Deere
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Gulraj S Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Yoav Ben-Shlomo
- Department of Population Health Sciences, University of Bristol, Bristol, UK
| | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - Ashley W Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Adrian Sayers
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK.,National Institute for Health Research Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| |
Collapse
|
8
|
Deere K, Matharu GS, Ben-Shlomo Y, Wilkinson JM, Blom AW, Sayers A, Whitehouse MR. The risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders with cobalt-chrome-containing total hip arthroplasty implants : an analysis of the National Joint Registry. Bone Joint J 2022:1-9. [PMID: 35018786 DOI: 10.1302/0301-620x.104b.bjj-2021-0397.r1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
AIMS A recent report from France suggested an association between the use of cobalt-chrome femoral heads in total hip arthroplasties (THAs) and an increased risk of dilated cardiomyopathy and heart failure. Cobalt-chrome is a commonly used material in orthopaedic implants. If the reported association is causal, the consequences would be significant given the millions of joint replacements and other orthopaedic procedures in which cobalt-chrome is used annually. We examined whether cobalt-chrome-containing THAs were associated with an increased risk of all-cause mortality, heart outcomes, cancer, and neurodegenerative disorders in a large national database. METHODS Data from the National Joint Registry was linked to NHS English hospital inpatient episodes for 374,359 primary THAs with up to 14.5 years follow-up. We excluded any patients with bilateral THAs, knee replacements, indications other than osteoarthritis, aged under 55 years, and diagnosis of one or more outcome of interest before THA. Implants were grouped as either containing cobalt-chrome or not containing cobalt-chrome. The association between implant construct and the risk of all-cause mortality and incident heart failure, cancer, and neurodegenerative disorders was examined. RESULTS There were 158,677 individuals (42.4%) with an implant containing cobalt-chrome. There were 47,963 deaths, 27,332 heart outcomes, 35,720 cancers, and 22,025 neurodegenerative disorders. There was no evidence of an association that patients with cobalt-chrome implants had higher rates of any of the outcomes. CONCLUSION Cobalt-chrome-containing THAs did not have an increased risk of all-cause mortality, or clinically meaningful heart outcomes, cancer or neurodegenerative disorders into the second decade post-implantation. Our findings will help reassure clinicians and the increasing number of patients receiving primary THA worldwide that the use of cobalt-chrome containing implants is not associated with significant adverse systemic effects.
Collapse
Affiliation(s)
- Kevin Deere
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Gulraj S Matharu
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Yoav Ben-Shlomo
- Department of Population Health Sciences, University of Bristol, Bristol, UK
| | - J Mark Wilkinson
- Department of Oncology and Metabolism, University of Sheffield, Sheffield, UK
| | - Ashley W Blom
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
- National Institute for Health Research, Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| | - Adrian Sayers
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
| | - Michael R Whitehouse
- Musculoskeletal Research Unit, Bristol Medical School, University of Bristol, Bristol, UK
- National Institute for Health Research, Bristol Biomedical Research Centre, University of Bristol, Bristol, UK
| |
Collapse
|
9
|
Badhe RV, Akinfosile O, Bijukumar D, Barba M, Mathew MT. Systemic toxicity eliciting metal ion levels from metallic implants and orthopedic devices - A mini review. Toxicol Lett 2021; 350:213-224. [PMID: 34252509 DOI: 10.1016/j.toxlet.2021.07.004] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2020] [Revised: 06/19/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
The metal/metal alloy-based implants and prostheses are in use for over a century, and the rejections, revisions, and metal particle-based toxicities were reported concurrently. Complications developed due to metal ions, metal debris, and organo-metallic particles in orthopedic patients have been a growing concern in recent years. It was reported that local and systemic toxicity caused by such released products from the implants is one of the major reasons for implant rejection and revision. Even though the description of environmental metal toxicants and safety limits for their exposure to humans were well established in the literature, an effort was not adequately performed in the case of implant-based metal toxicology. Since the metal ion concentration in serum acts as a possible indicator of the systemic toxicity, this review summarizes the reported human serum safe limits, toxic limits, and concentration range (μg/L, ppb, etc.) for mild to severe symptoms of six (cardiac, hepatic, neuro, nephron, dermal and endocrine) systemic toxicities for twelve most commonly used metallic implants. It also covers the widely used metal ion quantification techniques and systemic toxicity treatments reported.
Collapse
Affiliation(s)
- Ravindra V Badhe
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Obakanyin Akinfosile
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA
| | | | - Mathew T Mathew
- Department of Biomedical Sciences, University of Illinois College of Medicine at Rockford, Rockford, IL, USA.
| |
Collapse
|
10
|
Jenkinson MRJ, Meek RMD, Tate R, MacMillan S, Grant MH, Currie S. Cobalt-induced cardiomyopathy - do circulating cobalt levels matter? Bone Joint Res 2021; 10:340-347. [PMID: 34053230 PMCID: PMC8242681 DOI: 10.1302/2046-3758.106.bjr-2020-0414.r2] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Elevated levels of circulating cobalt ions have been linked with a wide range of systemic complications including neurological, endocrine, and cardiovascular symptoms. Case reports of patients with elevated blood cobalt ions have described significant cardiovascular complications including cardiomyopathy. However, correlation between the actual level of circulating cobalt and extent of cardiovascular injury has not previously been performed. This review examines evidence from the literature for a link between elevated blood cobalt levels secondary to metal-on-metal (MoM) hip arthroplasties and cardiomyopathy. Correlation between low, moderate, and high blood cobalt with cardiovascular complications has been considered. Elevated blood cobalt at levels over 250 µg/l have been shown to be a risk factor for developing systemic complications and published case reports document cardiomyopathy, cardiac transplantation, and death in patients with severely elevated blood cobalt ions. However, it is not clear that there is a hard cut-off value and cardiac dysfunction may occur at lower levels. Clinical and laboratory research has found conflicting evidence of cobalt-induced cardiomyopathy in patients with MoM hips. Further work needs to be done to clarify the link between severely elevated blood cobalt ions and cardiomyopathy. Cite this article: Bone Joint Res 2021;10(6):340–347.
Collapse
Affiliation(s)
| | | | - Rothwell Tate
- Strathclyde Institute of Pharmacy and Biomedical Sciences, University of Strathclyde, Glasgow, UK
| | | | - M Helen Grant
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| | - Susan Currie
- Biomedical Engineering, University of Strathclyde, Glasgow, UK
| |
Collapse
|
11
|
Umar M, Jahangir N, Khan MF, Saeed Z, Sultan F, Sultan A. Cobalt-related cardiomyopathy: A real concern! A review of published evidence. J Orthop Surg (Hong Kong) 2021; 28:2309499020905993. [PMID: 32410523 DOI: 10.1177/2309499020905993] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
BACKGROUND Cobalt (Co) toxicity-related cardiomyopathy (CMP) in hip arthroplasty has recently been reported in the literature. The purpose of this review was to identify and assess available published evidence of CMP in hip arthroplasty patients and to derive recommendations for management. METHODS We evaluated 23 cases reported till October 2018 and stratified into three categories, based on pre-existing risk factors for CMP, histological confirmation and evidence of systemic signs of Co toxicity. RESULTS Co toxicity was considered to be the definite cause of CMP in 8 cases and probably contributory in 13 cases. Two cases were considered to have developed CMP secondary to pre-existing risk factors. Majority of the patients had good recovery of cardiac function after hip revision and cardiac management, but five cases deteriorated and died. CONCLUSION Although Co-related CMP has been reported in a small number of cases of hip arthroplasty, a delay or missed diagnosis may lead to significant morbidity and mortality. Timely diagnosis, removal of causative implant and avoidance of metal articulations in revision for fractured ceramic implants may help in effective management.
Collapse
Affiliation(s)
- Muhammad Umar
- Macclesfield District General Hospital, Macclesfield, UK
| | | | | | - Zobia Saeed
- Macclesfield District General Hospital, Macclesfield, UK
| | - Farina Sultan
- Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| | - Ayyaz Sultan
- Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| |
Collapse
|
12
|
Manousek J, Felsoci M, Miklik R, Parenica J, Krejci J, Bjørklund G, Klanova J, Mlejnek D, Miklikova M, Lokaj P, Chirumbolo S, Spinar J. Delayed-type Hypersensitivity to Metals in Newly Diagnosed Patients with Nonischemic Dilated Cardiomyopathy. Cardiovasc Toxicol 2020; 20:571-580. [PMID: 32557318 DOI: 10.1007/s12012-020-09582-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The causes of nonischemic dilated cardiomyopathy are classified as genetic or nongenetic, but environmental factors such as metal pollutants may interact with genetic susceptibility. The presence of metal particles has been detected in the myocardium, including in those patients with dilated cardiomyopathy. It is also known that hypersensitivity reactions can induce inflammation in tissue. The present study aimed to verify if metal-induced delayed-type hypersensitivity is present in patients with nonischemic dilated cardiomyopathy. The patient group consisted of 30 patients with newly diagnosed dilated cardiomyopathy; the control group comprised 41 healthy subjects. All patients and control subjects provided blood samples for lymphocyte transformation testing (MELISA®) to assess possible hypersensitivity to seven common metals. Specific exposure to metals was based on interview data. Results showed that exposure to cadmium and lead (p = 0.0002), aluminum (p = 0.0006), nickel (p = 0.0012), and chromium (p = 0.0065) was more often reported by patients than controls. The patients also had significantly more frequent hypersensitivity reactions to mercury (26.7% vs. 7.3%, p = 0.014624), nickel (40% vs. 12.2%, p = 0.02341), and silver (20% vs. 4.8%, p = 0.025468) than the control group. Patients with dilated cardiomyopathy had greater exposure to certain metals compared with healthy controls. Hypersensitivity to metals was more frequent in patients with dilated cardiomyopathy, suggesting a possible association that warrants further investigation.
Collapse
Affiliation(s)
- Jan Manousek
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Marian Felsoci
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Roman Miklik
- Department of Cardiology, University Hospital and Faculty of Medicine Pilsen, Charles University, Prague, Czech Republic.
| | - Jiri Parenica
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Jan Krejci
- Department of Cardiovascular Diseases, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Geir Bjørklund
- Council for Nutritional and Environmental Medicine (CONEM), Toften 24, 8610, Mo i Rana, Norway.
| | - Jana Klanova
- Research Centre for Toxic Compounds in the Environment (RECETOX), Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Dalibor Mlejnek
- Department of Cardiovascular Diseases, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Marie Miklikova
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Petr Lokaj
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| | - Salvatore Chirumbolo
- Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy.,CONEM Scientific Secretary, Verona, Italy
| | - Jindrich Spinar
- Department of Internal Medicine and Cardiology, University Hospital Brno and Faculty of Medicine, Masaryk University, Brno, Czech Republic
| |
Collapse
|
13
|
Umar M, Jahangir N, Faisal Khan M, Saeed Z, Sultan F, Sultan A. Cobalt cardiomyopathy in hip arthroplasty. Arthroplast Today 2019; 5:371-375. [PMID: 31516984 PMCID: PMC6728440 DOI: 10.1016/j.artd.2019.04.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/25/2019] [Revised: 04/26/2019] [Accepted: 04/27/2019] [Indexed: 01/25/2023] Open
Abstract
Background Cobalt toxicity-related cardiomyopathy in hip arthroplasty has recently been reported in the literature. The purpose of this review is to identify and assess available published evidence of cardiomyopathy in hip arthroplasty patients and to derive recommendations for management. Methods We evaluated 23 cases reported until October 2018 and stratified them into 3 categories, based upon pre-existing risk factors for cardiomyopathy, histological confirmation, and evidence of systemic signs of cobalt toxicity. Results Cobalt toxicity was considered to be the definite cause of cardiomyopathy in 8 cases, and probably contributory in 13 cases. Two cases were considered to have developed cardiomyopathy secondary to pre-existing risk factors. Majority of the patients had a good recovery of cardiac function after hip revision and cardiac management, but 5 cases deteriorated and died. Conclusions Although cobalt-related cardiomyopathy has been reported in a small number of cases of hip arthroplasty, a delay or missed diagnosis may lead to significant morbidity and mortality. Timely diagnosis, removal of causative implant, and avoidance of metal articulations in revision for fractured ceramic implants may help in an effective management.
Collapse
Affiliation(s)
- Muhammad Umar
- Department of Trauma and Orthopaedics, Macclesfield District General Hospital, Macclesfield, UK
| | - Noman Jahangir
- Department of Trauma and Orthopaedics, Wythenshawe Hospital, Manchester, UK
| | | | - Zobia Saeed
- Department of Trauma and Orthopaedics, Macclesfield District General Hospital, Macclesfield, UK
| | - Farina Sultan
- Department of Cardiology, Royal Albert Edward Infirmary Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| | - Ayyaz Sultan
- Department of Cardiology, Royal Albert Edward Infirmary Wrightington, Wigan & Leigh NHS Foundation Trust, Wigan, UK
| |
Collapse
|
14
|
Matharu GS, Whitehouse MR. Letter to the Editor: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:2459-2461. [PMID: 30427316 PMCID: PMC6259882 DOI: 10.1097/corr.0000000000000524] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/30/2018] [Accepted: 09/19/2018] [Indexed: 01/31/2023]
Affiliation(s)
- Gulraj S Matharu
- G. S. Matharu, Clinical Lecturer in Trauma and Orthopaedic Surgery, Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK M. R. Whitehouse, Musculoskeletal Research Unit, Translational Health Sciences, Bristol Medical School, University of Bristol, Bristol, UK, & National Institute for Health Research Bristol Biomedical Research Centre, University Hospitals Bristol NHS Foundation Trust and University of Bristol, Bristol, UK
| | | |
Collapse
|
15
|
Reply to the Letter to the Editor: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:2462-2463. [PMID: 30427317 PMCID: PMC6259886 DOI: 10.1097/corr.0000000000000525] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|
16
|
CORR Insights®: Is There a Cardiotoxicity Associated With Metallic Head Hip Prostheses? A Cohort Study in the French National Health Insurance Databases. Clin Orthop Relat Res 2018; 476:1452-1454. [PMID: 29846204 PMCID: PMC6437569 DOI: 10.1097/corr.0000000000000355] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/31/2023]
|