1
|
Leali M, Marongiu I, Spinelli E, Chiavieri V, Perez J, Panigada M, Grasselli G, Mauri T. Absolute values of regional ventilation-perfusion mismatch in patients with ARDS monitored by electrical impedance tomography and the role of dead space and shunt compensation. Crit Care 2024; 28:241. [PMID: 39010228 PMCID: PMC11251389 DOI: 10.1186/s13054-024-05033-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2024] [Accepted: 07/11/2024] [Indexed: 07/17/2024] Open
Abstract
BACKGROUND Assessment of regional ventilation/perfusion (V'/Q) mismatch using electrical impedance tomography (EIT) represents a promising advancement for personalized management of the acute respiratory distress syndrome (ARDS). However, accuracy is still hindered by the need for invasive monitoring to calibrate ventilation and perfusion. Here, we propose a non-invasive correction that uses only EIT data and characterized patients with more pronounced compensation of V'/Q mismatch. METHODS We enrolled twenty-one ARDS patients on controlled mechanical ventilation. Cardiac output was measured invasively, and ventilation and perfusion were assessed by EIT. Relative V'/Q maps by EIT were calibrated to absolute values using the minute ventilation to invasive cardiac output (MV/CO) ratio (V'/Q-ABS), left unadjusted (V'/Q-REL), or corrected by MV/CO ratio derived from EIT data (V'/Q-CORR). The ratio between ventilation to dependent regions and perfusion reaching shunted units ( V D ' /QSHUNT) was calculated as an index of more effective hypoxic pulmonary vasoconstriction. The ratio between perfusion to non-dependent regions and ventilation to dead space units (QND/ V DS ' ) was calculated as an index of hypocapnic pneumoconstriction. RESULTS Our calibration factor correlated with invasive MV/CO (r = 0.65, p < 0.001), showed good accuracy and no apparent bias. Compared to V'/Q-ABS, V'/Q-REL maps overestimated ventilation (p = 0.013) and perfusion (p = 0.002) to low V'/Q units and underestimated ventilation (p = 0.011) and perfusion (p = 0.008) to high V'/Q units. The heterogeneity of ventilation and perfusion reaching different V'/Q compartments was underestimated. V'/Q-CORR maps eliminated all these differences with V'/Q-ABS (p > 0.05). HigherV D ' / Q SHUNT correlated with higher PaO2/FiO2 (r = 0.49, p = 0.025) and lower shunt fraction (ρ = - 0.59, p = 0.005). HigherQ ND / V DS ' correlated with lower PEEP (ρ = - 0.62, p = 0.003) and plateau pressure (ρ = - 0.59, p = 0.005). Lower values of both indexes were associated with less ventilator-free days (p = 0.05 and p = 0.03, respectively). CONCLUSIONS Regional V'/Q maps calibrated with a non-invasive EIT-only method closely approximate the ones obtained with invasive monitoring. Higher efficiency of shunt compensation improves oxygenation while compensation of dead space is less needed at lower airway pressure. Patients with more effective compensation mechanisms could have better outcomes.
Collapse
Affiliation(s)
- Marco Leali
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Ines Marongiu
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Elena Spinelli
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Valentina Chiavieri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
| | - Joaquin Perez
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Mauro Panigada
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Giacomo Grasselli
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy
| | - Tommaso Mauri
- Department of Pathophysiology and Transplantation, University of Milan, Milan, Italy.
- Department of Anesthesia, Critical Care and Emergency, Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico, Milan, Italy.
| |
Collapse
|
2
|
Victor MH, Ribeiro AS, Matsumoto MMS, Xin Y, Tanaka H, Cereda M. Time-domain and 3D methods for lung perfusion data clustering in electrical impedance tomography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039753 PMCID: PMC11969328 DOI: 10.1109/embc53108.2024.10782067] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
The paper discusses the use of clustering methods to segment electrical impedance tomography images when assessing pulmonary perfusion through hypertonic saline injection. The clustering method assumes hybrid pixels (with both heart and lung partial volume effects) and lung pixels (solely due to lung perfusion). The study used data from 51 perfusions in 8 healthy and injured mechanically ventilated swine to generate ground truth masks and evaluate the clustering performance. Among the compared methods, k-means method with the correlation metric, was found to be the most effective and balanced performance. Achieving a median sensitivity and specificity of 84% while aiming to minimize false negative cases. This is important for avoiding the attribution of high lung perfusion values to voxels with mixed heart and lung effects.
Collapse
|
3
|
Victor MH, Pardini GR, Matsumoto MMS, Xin Y, Tanaka H, Cereda M. Noise effect analysis and pulmonary perfusion estimation in electrical impedance tomography. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2024; 2024:1-4. [PMID: 40039384 PMCID: PMC12011017 DOI: 10.1109/embc53108.2024.10781660] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/06/2025]
Abstract
Electrical Impedance Tomography (EIT) is a non-invasive imaging technique used to monitor mechanically ventilated patients at the bedside. This study focuses on evaluating the estimation of pulmonary perfusion and the effects of two common noise sources on the outcomes of a hypertonic saline contrast bolus procedure. We used the first-pass kinetics modeling in EIT data to estimate purely lung and hybrid pixels. Furthermore, we analyzed how signal drift and cardiac partial volume effect can yield misleading outcomes. If left uncompensated, the drift noise showed an overestimation of 33%, while the cardiac partial volume effect showed an underestimation of 13.9% in the maximum slope value. We evaluated the model performance using simulated and actual data within physiologically feasible limits.
Collapse
|
4
|
Gaulton TG, Xin Y, Victor M, Nova A, Cereda M. Imaging the pulmonary vasculature in acute respiratory distress syndrome. Nitric Oxide 2024; 147:6-12. [PMID: 38588918 PMCID: PMC11253040 DOI: 10.1016/j.niox.2024.04.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2024] [Revised: 03/21/2024] [Accepted: 04/03/2024] [Indexed: 04/10/2024]
Abstract
Acute respiratory distress syndrome (ARDS) is characterized by a redistribution of regional lung perfusion that impairs gas exchange. While speculative, experimental evidence suggests that perfusion redistribution may contribute to regional inflammation and modify disease progression. Unfortunately, tools to visualize and quantify lung perfusion in patients with ARDS are lacking. This review explores recent advances in perfusion imaging techniques that aim to understand the pulmonary circulation in ARDS. Dynamic contrast-enhanced computed tomography captures first-pass kinetics of intravenously injected dye during continuous scan acquisitions. Different contrast characteristics and kinetic modeling have improved its topographic measurement of pulmonary perfusion with high spatial and temporal resolution. Dual-energy computed tomography can map the pulmonary blood volume of the whole lung with limited radiation exposure, enabling its application in clinical research. Electrical impedance tomography can obtain serial topographic assessments of perfusion at the bedside in response to treatments such as inhaled nitric oxide and prone position. Ongoing technological improvements and emerging techniques will enhance lung perfusion imaging and aid its incorporation into the care of patients with ARDS.
Collapse
Affiliation(s)
- Timothy G Gaulton
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA.
| | - Yi Xin
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Marcus Victor
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA; Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil
| | - Alice Nova
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| | - Maurizio Cereda
- Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Boston, MA, USA; Department of Anesthesia, Critical Care and Pain Medicine, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
5
|
Victor M, Xin Y, Alcala G, Gaulton T, Costa E, Winkler T, Berra L, Amato M, Cereda M. First-Pass Kinetics Model to Estimate Pulmonary Perfusion by Electrical Impedance Tomography During Uninterrupted Breathing. Am J Respir Crit Care Med 2024; 209:1263-1265. [PMID: 38412326 PMCID: PMC11146534 DOI: 10.1164/rccm.202310-1919le] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2023] [Accepted: 02/27/2024] [Indexed: 02/29/2024] Open
Affiliation(s)
- Marcus Victor
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
- Electronics Engineering Division, Aeronautics Institute of Technology, Sao Paulo, Brazil; and
| | - Yi Xin
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Glasiele Alcala
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Timothy Gaulton
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Eduardo Costa
- Disciplina de Pneumologia, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, Sao Paulo, Brazil
| | - Tilo Winkler
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Lorenzo Berra
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| | - Marcelo Amato
- Disciplina de Pneumologia, Instituto do Coração, Hospital das Clínicas, Faculdade de Medicina, Universidade de São Paulo, Sao Paulo, Brazil
| | - Maurizio Cereda
- Department of Anesthesia, Critical Care, and Pain Medicine, Massachusetts General Hospital, Boston, Massachusetts
- Department of Anesthesia, Critical Care, and Pain Medicine, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
6
|
Ribeiro BM, Tucci MR, Victor Júnior MH, Melo JR, Gomes S, Nakamura MAM, Morais CCA, Beraldo MA, Lima CAS, Alcala GC, Amato MBP. Influence of Fractional Inspired Oxygen Tension on Lung Perfusion Distribution, Regional Ventilation, and Lung Volume during Mechanical Ventilation of Supine Healthy Swine. Anesthesiology 2024; 140:752-764. [PMID: 38207290 DOI: 10.1097/aln.0000000000004903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2024]
Abstract
BACKGROUND Lower fractional inspired oxygen tension (Fio2) during general anesthesia can reduce lung atelectasis. The objectives are to evaluate the effect of two Fio2 (0.4 and 1) during low positive end-expiratory pressure (PEEP) ventilation over lung perfusion distribution, volume, and regional ventilation. These variables were evaluated at two PEEP levels and unilateral lung atelectasis. METHODS In this exploratory study, 10 healthy female piglets (32.3 ± 3.4 kg) underwent mechanical ventilation in two atelectasis models: (1) bilateral gravitational atelectasis (n = 6), induced by changes in PEEP and Fio2 in three combinations: high PEEP with low Fio2 (Fio2 = 0.4), zero PEEP (PEEP0) with low Fio2 (Fio2 = 0.4), and PEEP0 with high Fio2 (Fio2 = 1); and (2) unilateral atelectasis (n = 6), induced by left bronchial occlusion, with the left lung aerated (Fio2 = 0.21) and low aerated (Fio2 = 1; n = 5 for this step). Measurements were conducted after 10 min in each step, encompassing assessment of respiratory mechanics, oxygenation, and hemodynamics; lung ventilation and perfusion by electrical impedance tomography; and lung aeration and perfusion by computed tomography. RESULTS During bilateral gravitational atelectasis, PEEP reduction increased atelectasis in dorsal regions, decreased respiratory compliance, and distributed lung ventilation to ventral regions with a parallel shift of perfusion to the same areas. With PEEP0, there were no differences between low and high Fio2 in respiratory compliance (23.9 ± 6.5 ml/cm H2O vs. 21.9 ± 5.0; P = 0.441), regional ventilation, and regional perfusion, despite higher lung collapse (18.6 ± 7.6% vs. 32.7 ± 14.5%; P = 0.045) with high Fio2. During unilateral lung atelectasis, the deaerated lung had a lower shunt (19.3 ± 3.6% vs. 25.3 ± 5.5%; P = 0.045) and lower computed tomography perfusion to the left lung (8.8 ± 1.8% vs. 23.8 ± 7.1%; P = 0.007). CONCLUSIONS PEEP0 with low Fio2, compared with high Fio2, did not produce significant changes in respiratory system compliance, regional lung ventilation, and perfusion despite significantly lower lung collapse. After left bronchial occlusion, the shrinkage of the parenchyma with Fio2 = 1 enhanced hypoxic pulmonary vasoconstriction, reducing intrapulmonary shunt and perfusion of the nonventilated areas. EDITOR’S PERSPECTIVE
Collapse
Affiliation(s)
- Bruno M Ribeiro
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Mauro R Tucci
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcus H Victor Júnior
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil; Electronics Engineering, Aeronautics Institute of Technology, Sao Jose dos Campos, Brazil
| | - Jose R Melo
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Susimeire Gomes
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Maria A M Nakamura
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Caio C A Morais
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcelo A Beraldo
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Cristhiano A S Lima
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Glasiele C Alcala
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| | - Marcelo B P Amato
- Laboratorio de Pneumologia LIM-09, Disciplina de Pneumologia, Instituto de Cardiologia (Incor), Hospital das Clinicas da Faculdade de Medicina da Universidade de Sao Paulo, Sao Paulo, Brazil
| |
Collapse
|
7
|
Silva D, Muders T, Wodack K, Putensen C, Leonhardt S, Siepmann R, Hentze B, Reinartz S. Pulmonary CT perfusion robustly measures cardiac output in the context of multilevel pulmonary occlusion: a porcine study. Eur Radiol Exp 2024; 8:51. [PMID: 38517595 PMCID: PMC10959917 DOI: 10.1186/s41747-024-00431-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Accepted: 01/09/2024] [Indexed: 03/24/2024] Open
Abstract
BACKGROUND To validate pulmonary computed tomography (CT) perfusion in a porcine model by invasive monitoring of cardiac output (CO) using thermodilution method. METHODS Animals were studied at a single center, using a Swan-Ganz catheter for invasive CO monitoring as a reference. Fifteen pigs were included. Contrast-enhanced CT perfusion of the descending aorta and right and left pulmonary artery was performed. For variation purposes, a balloon catheter was inserted to block the contralateral pulmonary vascular bed; additionally, two increased CO settings were created by intravenous administration of catecholamines. Finally, stepwise capillary occlusion was performed by intrapulmonary arterial injection of 75-μm microspheres in four stages. A semiautomatic selection of AFs and a recirculation-aware tracer-kinetics model to extract the first-pass of AFs, estimating blood flow with the Stewart-Hamilton method, was implemented. Linear mixed models (LMM) were developed to calibrate blood flow calculations accounting with individual- and cohort-level effects. RESULTS Nine of 15 pigs had complete datasets. Strong correlations were observed between calibrated pulmonary (0.73, 95% confidence interval [CI] 0.6-0.82) and aortic blood flow measurements (0.82, 95% CI, 0.73-0.88) and the reference as well as agreements (± 2.24 L/min and ± 1.86 L/min, respectively) comparable to the state of the art, on a relatively wide range of right ventricle-CO measurements. CONCLUSIONS CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by referencing the invasive CO. RELEVANCE STATEMENT Possible clinical applications of CT perfusion for measuring CO could be in acute pulmonary thromboembolism or to assess right ventricular function to show impairment or mismatch to the left ventricle. KEY POINTS • CT perfusion measures flow in vessels. • CT perfusion measures cumulative cardiac output in the aorta and pulmonary vessels. • CT perfusion validly measures CO using LMMs at both individual and cohort levels, as demonstrated by using the invasive CO as a reference standard.
Collapse
Affiliation(s)
- Diogo Silva
- Medical Information Technology (MedIT), RWTH Aachen University, Aachen, Germany
| | - Thomas Muders
- Department of Anaesthesiology and Intensive Care Medicine, University Bonn, Bonn, Germany
| | - Karin Wodack
- Department of Anaesthesiology and Intensive Care Medicine, University Bonn, Bonn, Germany
| | - Christian Putensen
- Department of Anaesthesiology and Intensive Care Medicine, University Bonn, Bonn, Germany
| | - Steffen Leonhardt
- Medical Information Technology (MedIT), RWTH Aachen University, Aachen, Germany
| | - Robert Siepmann
- Department of Diagnostic and Interventional Radiology, Uniklinik RWTH Aachen, Aachen, Germany
| | - Benjamin Hentze
- Medical Information Technology (MedIT), RWTH Aachen University, Aachen, Germany
- Department of Anaesthesiology and Intensive Care Medicine, University Bonn, Bonn, Germany
| | - Sebastian Reinartz
- Department of Diagnostic and Interventional Radiology, Uniklinik RWTH Aachen, Aachen, Germany.
| |
Collapse
|