1
|
Lee S, Sato H, Miyawaki Y, Hisaoka K, Takabatake K, Toriumi T, Ebara G, Sugita H, Sakuramoto S. Evaluation of the blood flow in reconstructed gastric tube and its relation to anastomosis leakage. Gen Thorac Cardiovasc Surg 2024; 72:608-616. [PMID: 38748379 PMCID: PMC11339079 DOI: 10.1007/s11748-024-02038-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2023] [Accepted: 04/19/2024] [Indexed: 08/22/2024]
Abstract
OBJECTIVES Anastomotic leakage in esophageal cancer surgery may be reduced by evaluating the blood flow to the reconstructed organ, but quantitative evaluation of arterial and venous blood flow is difficult. This study aimed to quantitatively assess blood flow using a new technique, as well as determine the relationship between the blood flow in the gastric tube and anastomotic leakage using near-infrared spectroscopy. METHODS This single-center, observational study included 50 patients aged 51-82 years who underwent radical esophagectomy with gastric tube reconstruction for esophageal cancer between June 2022 and January 2023. Regional tissue oxygen saturation was measured at the antrum (point X), the anastomotic point (point Z), and the midpoint between points X and Z (point Y) before and after gastric tube formation. These three points of oxygen saturation were investigated in relation to anastomotic leakage. RESULTS When comparing the presence of leakage to its absence, regional tissue oxygen saturation at points X and Z after gastric tube formation was significantly lower (X: p = 0.03, Z: p = 0.02), with the decreasing rate significantly higher at point Z (p = 0.01). There was no significant difference in the decreasing rate of regional tissue oxygen saturation between points X and Y (X: p = 0.052, Y: p = 0.83). CONCLUSION Regional tissue oxygen saturation levels may be useful for measuring blood flow and could be a predictor of anastomotic leakage.
Collapse
Affiliation(s)
- Seigi Lee
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan.
| | - Hiroshi Sato
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Yutaka Miyawaki
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Kazuhiko Hisaoka
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Kazuya Takabatake
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Tetsuro Toriumi
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Gen Ebara
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Hirofumi Sugita
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| | - Shinichi Sakuramoto
- Department of Gastrointestinal Surgery, Saitama Medical University International Medical Center, 1397-1, Yamane, Hidaka, Saitama, 350-1298, Japan
| |
Collapse
|
2
|
Fujita T, Shigeno T, Kajiyama D, Sato K, Fujiwara N, Daiko H. A novel device to assess the oxygen saturation and congestion status of the gastric conduit in thoracic esophagectomy. BMC Surg 2024; 24:17. [PMID: 38191379 PMCID: PMC10775575 DOI: 10.1186/s12893-023-02303-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Accepted: 12/26/2023] [Indexed: 01/10/2024] Open
Abstract
BACKGROUND In thoracic esophagectomy, anastomotic leakage is one of the most important surgical complications. Indocyanine green (ICG) is the most widely used method to assess tissue blood flow; however, this technique has been pointed out to have disadvantages such as difficulty in evaluating the degree of congestion, lack of objectivity in evaluating the degree of staining, and bias easily caused by ICG injection, camera distance, and other factors. Evaluating tissue oxygen saturation (StO2) overcomes these disadvantages and can be performed easily and repeatedly. It is also possible to measure objective values including the degree of congestion. We evaluate novel imaging technology to assess tissue oxygen saturation (StO2) in the gastric conduit during thoracic esophagectomy. METHODS Fifty patients were enrolled, with seven excluded due to intraoperative findings, leaving 43 for analysis. These patients underwent thoracic esophagectomy for esophageal cancer. The device was used intraoperatively to evaluate tissue oxygen saturation (StO2) and total hemoglobin index (T-HbI), which guided the optimal site for gastric tube anastomosis. The efficacies of StO2 and T-HbI in relation to short-term outcomes were analyzed. RESULTS StO2, indicating blood supply to the gastric tube, remained stable beyond the right gastroepiploic artery (RGEA) end but significantly decreased distally to the demarcation line (p < 0.05). T-HbI, indicative of congestion, significantly decreased past the RGEA (p < 0.05). Three patients experienced anastomotic leakage. These patients exhibited significantly lower StO2 (p < 0.01) and higher T-HbI (p < 0.01) at both the RGEA end and the demarcation line. Furthermore, the anastomotic site, usually within 3 cm of the RGEA's anorectal side, also showed significantly lower StO2 (p < 0.01) and higher T-HbI (p < 0.01) in patients with anastomotic leakage. CONCLUSIONS The novel device provides real-time, objective evaluations of blood flow and congestion in the gastric tube. It proves useful for safer reconstruction during thoracic esophagectomy, particularly by identifying optimal anastomosis sites and predicting potential anastomotic leakage.
Collapse
Affiliation(s)
- Takeo Fujita
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan.
| | - Takashi Shigeno
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Daisuke Kajiyama
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Kazuma Sato
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Naoto Fujiwara
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| | - Hiroyuki Daiko
- Division of Esophageal Surgery, National Cancer Center Hospital East, 6-5-1 Kashiwanoha, Kashiwa, Chiba, 277-8577, Japan
| |
Collapse
|
3
|
Fingerstall-type Tissue Oximetry Reduced Anxiety of Nurses in Postoperative Nursing Monitoring of Free Flaps. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2021; 9:e3991. [PMID: 34938644 PMCID: PMC8687730 DOI: 10.1097/gox.0000000000003991] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2021] [Accepted: 10/25/2021] [Indexed: 11/25/2022]
Abstract
Postoperative free flap monitoring is essential for immediately detecting obstruction of anastomosed vessels with successive recovery surgery for salvaging flaps. We performed postoperative nursing monitoring using handheld Doppler sonography, but nurses reported feeling anxious with this approach and demanded a clear-cut evaluation method. Therefore, we implemented monitoring with the fingerstall-type tissue oximeter Toccare, a noninvasive device that enables easy flap checking by simply touching the flap with a probe.
Collapse
|
4
|
Ishii K, Tsubosa Y, Mayanagi S, Inoue M, Haneda R. Tissue Oxygen Saturation during Gastric Tube Reconstruction with Cervical Anastomosis for Esophagectomy: A Case Series. J INVEST SURG 2021; 35:809-813. [PMID: 34542377 DOI: 10.1080/08941939.2021.1968080] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND One cause of anastomotic leakage after radical esophagectomy is blood flow insufficiency at the cervical anastomosis site. . METHODS Eighteen patients, who underwent radical esophagectomy with gastric tube reconstruction, were studied. The regional tissue oxygen saturation (rSO2) was measured at the tip (point pre 0) and 2, 4, and 6 cm on the distal side of the tip (point pre 1, pre 2, and pre 3, respectively) before the gastric tube was raised to the cervical site through the retrosternal route. After that, rSO2 was measured at the tip, 2 and 4 cm on the distal side of the tip (points post 0, post 1, and post 2), the actual anastomotic site (point AN), and the chest skin as an indicator of whole-body oxygenation. The relationship between rSO2 scores and the rate of anastomotic leakage was determined. RESULTS The mean rSO2 at pre 0, pre 1, pre 2, and pre 3 were 48.9%, 52.3%, 54.8%, and 56.9%, respectively (p < 0.05). The mean rSO2 at post 0, post 1, and post 2 were 47.8%, 50.5%, and 52.3%, respectively, and the rSO2 at point AN was 52.1%.Anastomotic leakage was found in 6 patients. The rSO2 at points pre 0, pre 1, and pre 2, post 0 and point AN were significantly lower in patients with anastomosis leakage than those without (p < 0.05). CONCLUSION Tissue oxygen saturation monitoring was a useful indicator of blood flow insufficiency in the gastric tube during radical esophagectomy.
Collapse
Affiliation(s)
- Kenjiro Ishii
- Division of Esophageal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| | - Yasuhiro Tsubosa
- Division of Esophageal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| | - Shuhei Mayanagi
- Division of Esophageal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| | - Masazumi Inoue
- Division of Esophageal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| | - Ryoma Haneda
- Division of Esophageal Surgery, Shizuoka Cancer Center, Shizuoka, Japan
| |
Collapse
|
5
|
Niwayama M, Unno N. Tissue Oximeter with Selectable Measurement Depth Using Spatially Resolved Near-Infrared Spectroscopy. SENSORS 2021; 21:s21165573. [PMID: 34451015 PMCID: PMC8402253 DOI: 10.3390/s21165573] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Revised: 08/14/2021] [Accepted: 08/16/2021] [Indexed: 12/19/2022]
Abstract
Tissue oxygenation sensing at a few millimeters deep is useful for surgical and postoperative management. However, the measurement sensitivity at each depth and the proper sensor combination have not been clarified. Here, the measurement characteristics of oximetry by spatially resolved near-infrared spectroscopy were analyzed using Monte Carlo simulation and phantom experiment. From summing the sensitivities of each depth, it was quantitatively found that the measurement sensitivity curve had a peak, and the measurement depth can be adjusted by combining the two distances between the light source and the detector. Furthermore, the gastric tissue was 10–20% smaller in terms of measurement depth than the skin-subcutaneous tissue. A miniaturized oximeter was prototyped so that it could be used in combination with an endoscope or laparoscope. The optical probes consisted of light emitting diodes with wavelengths of 770 nm and 830 nm and photodetectors located 3 to 30 mm from the light source. Phantom experiments using the probes demonstrated the tendency of theoretical analysis. These results suggest the possibility of measuring tissue oxygen saturation with a selectable measurement depth. This selectable method will be useful for obtaining oxygenation information at a depth of 2–5 mm, which is difficult to measure using only laparoscopic surface imaging.
Collapse
Affiliation(s)
- Masatsugu Niwayama
- Graduate School of Medical Photonics, Shizuoka University, Hamamatsu 432-8561, Japan
- Correspondence: ; Tel.: +81-534781615
| | - Naoki Unno
- Division of Vascular Surgery, Hamamatsu University School of Medicine, Hamamatsu 431-3192, Japan;
| |
Collapse
|
6
|
Suzuki Y, Yamamoto M, Sugiyama K, Akai T, Suzuki K, Kawamura T, Sakata M, Morita Y, Kikuchi H, Hiramatsu Y, Kurachi K, Unno N, Takeuchi H. Usefulness of a finger-mounted tissue oximeter with near-infrared spectroscopy for evaluating the intestinal oxygenation and viability in rats. Surg Today 2021; 51:931-940. [PMID: 33108523 PMCID: PMC8141489 DOI: 10.1007/s00595-020-02171-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Accepted: 09/26/2020] [Indexed: 12/04/2022]
Abstract
PURPOSE To investigate the utility of the device for evaluating intestinal oxygenation and viability using an animal model. METHODS Sprague-Dawley rats underwent laparotomy under general anesthesia, and the blood vessels in the terminal ileum were clamped to create ischemia. We measured the regional tissue oxygenation saturation (rSO2) using an oximeter after 1, 3, and 6 h of vessel clamping. Ischemic tissue damage was assessed using a histological score. The intestine was reperfused after each clamping period, and intestinal rSO2 and survival rate were evaluated. RESULTS When reperfusion was performed at 1 and 3 h after ischemia, rSO2 increased after 10 min, and it improved to the same level as for normal intestine after 1 h; all rats survived for 1 week. In contrast, after 6 h of ischemia, rSO2 did not increase after reperfusion, and all animals died within 2 days. The histological scores increased after 1 h of reperfusion, with longer clamping periods. CONCLUSION A finger-mounted tissue oximeter could evaluate intestinal ischemia and the viability, which is thus considered to be a promising result for future clinical application.
Collapse
Affiliation(s)
- Yuhi Suzuki
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan.
| | - Masayoshi Yamamoto
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Kosuke Sugiyama
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Toshiya Akai
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Katsunori Suzuki
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Takafumi Kawamura
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Mayu Sakata
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Yoshifumi Morita
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Hirotoshi Kikuchi
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Yoshihiro Hiramatsu
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Kiyotaka Kurachi
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| | - Naoki Unno
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
- Division of Vascular Surgery, Hamamatsu Medical Center, 328 Tomitsuka, Hamamatsu, Shizuoka, 432-8580, Japan
| | - Hiroya Takeuchi
- Second Department of Surgery, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu, Shizuoka, 431-3192, Japan
| |
Collapse
|
7
|
Yamaguchi K, Nakajima Y, Matsui T, Okuda M, Okada T, Hoshino A, Tokairin Y, Kawada K, Kawano T, Kinugasa Y. The evaluation of the hemodynamics of a gastric tube in esophagectomy using a new noninvasive blood flow evaluation device utilizing near-infrared spectroscopy. Gen Thorac Cardiovasc Surg 2020; 68:841-847. [PMID: 32285303 DOI: 10.1007/s11748-020-01350-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2020] [Accepted: 03/31/2020] [Indexed: 11/25/2022]
Abstract
OBJECTIVE We herein evaluated the hemodynamics of a gastric tube in esophagectomy using a new noninvasive blood flow evaluation device utilizing near-infrared spectroscopy. METHODS Thirty-two cases of subtotal esophagectomy and gastric tube reconstruction for esophageal cancer were studied. The new device measures the regional tissue saturation of oxygen (rSO2: 0-99%) and total hemoglobin index (T-HbI: 0-1.0) with a small sensor. We measured these values at the antrum (point A), final branch of the right gastroepiploic artery (point B) and planned anastomotic point (point C) before and after gastric tube formation. The values at the three points were compared, and the gradients at the three points from before to after gastric tube formation were compared. RESULTS The mean values of rSO2 at point A, B, and C before gastric tube formation were 57.2%, 57.8% and 56.0%, and those after formation were 54.6%, 58.0% and 55.8%, respectively. There was no significant difference in the comparison of the rSO2 gradient before and after formation (p = 0.167). The mean values of T-HbI at point A, B, and C before formation were 0.126, 0.178 and 0.211, and those after formation were 0.167, 0.247 and 0.292, respectively. There was no significant difference in the gradient of the increase before and after formation (p = 0.461). CONCLUSION A new device has shown that the gastric tube used in our facility is one that maintains tissue saturation of oxygen and does not cause excessive congestion at anastomosis.
Collapse
Affiliation(s)
- Kazuya Yamaguchi
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan.
| | - Yasuaki Nakajima
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Toshihiro Matsui
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Masafumi Okuda
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Takuya Okada
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Akihiro Hoshino
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Yutaka Tokairin
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Kenro Kawada
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| | - Tatsuyuki Kawano
- Department of Surgery, Soka Municipal Hospital, 2-21-1 Soka, Soka-shi, Saitama, 340-8560, Japan
| | - Yusuke Kinugasa
- Department of Gastrointestinal Surgery, Tokyo Medical and Dental University, 1-5-45 Yushima, Bunkyo-ku, Tokyo, 113-8510, Japan
| |
Collapse
|
8
|
Determining Transverse Rectus Abdominis Musculo-cutaneous Flap Viability using Fingerstall-type Tissue Oximetry as an Alternative to Indocyanine Green Fluorescence Imaging: A Case of a Patient with Iodine Hypersensitivity. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2018; 6:e1966. [PMID: 30349801 PMCID: PMC6191207 DOI: 10.1097/gox.0000000000001966] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2018] [Accepted: 08/07/2018] [Indexed: 11/25/2022]
|