1
|
Swanson E. Abdominal Fascial Plication and the Risk of Venous Thromboembolism in Abdominoplasty Patients: A Systematic Review of the Literature. Ann Plast Surg 2025; 94:378-383. [PMID: 39774064 PMCID: PMC11902602 DOI: 10.1097/sap.0000000000004149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2024] [Revised: 09/11/2024] [Indexed: 01/11/2025]
Abstract
BACKGROUND Repair of the abdominal fascia at the time of abdominoplasty is a valuable method to improve the contour of the abdomen. However, this maneuver has been linked to an increased risk of venous thromboembolism (VTE). This review was undertaken to evaluate the evidence. METHODS An electronic literature review was conducted to identify publications on the subject of abdominal fascial repair during abdominoplasty and VTE risk. Key words included abdominoplasty, fascial plication, intra-abdominal pressure, and venous thrombosis. RESULTS Three large clinical studies were identified. One retrospective study using matched comparisons reported nearly identical VTE rates for patients treated with and without abdominal fascial plication (1.5% vs 1.7%). Another retrospective study reported significantly more VTEs (2.3%) in abdominoplasty patients undergoing fascial repair compared with panniculectomy patients who did not undergo fascial plication (0.36%). The author also recommended a modified Caprini score, adding fascial repair as a risk factor. Only 1 prospective study reported a large number of consecutive plastic surgery outpatients evaluated with Doppler ultrasound. This group included 188 abdominoplasty patients, all treated with fascial plication and without muscle paralysis. Only 1 VTE was diagnosed on the day after abdominoplasty (0.5%). DISCUSSION Retrospective studies are susceptible to confounders and confirmation bias. Caprini scores do not have a scientific foundation. Chemoprophylaxis increases the risk of bleeding without reducing the risk of VTE. CONCLUSIONS The best available evidence supports performing a fascial repair. An effective and safe alternative to Caprini scores and chemoprophylaxis is avoidance of muscle paralysis and early detection of VTEs using ultrasound screening.
Collapse
|
2
|
Vejbrink Kildal V, Rodriguez-Lorenzo A, Pruidze P, Reissig L, Weninger WJ, Tzou CHJ, Jonsson L, Meng S. Ultrasound-Guided Injections for Treatment of Facial Paralysis Sequelae: A Randomized Study on Body Donors. Plast Reconstr Surg 2024; 153:617e-625e. [PMID: 37285208 DOI: 10.1097/prs.0000000000010802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
BACKGROUND Botulinum toxin injection is the accepted standard treatment for synkinesis and gustatory hyperlacrimation in patients with facial paralysis. However, poor injection accuracy can result in inconsistent treatment outcomes, variable treatment durations, and complications. Ultrasound guidance should increase injection accuracy in the facial region; however, this has not been proven. METHODS Twenty-six hemifaces of nonembalmed cadavers were studied in a randomized split-face manner. Ink was injected with ultrasound or landmark guidance into the lacrimal gland and three common synkinetic muscles: the orbicularis oculi, depressor anguli oris, and mentalis. Injection accuracy was evaluated using several measures. RESULTS Using ultrasound guidance, most ink (>50%) was found inside the correct target in 88% of cases, compared with 50% using landmark guidance ( P < 0.001). This was most pronounced in the lacrimal gland (62% versus 8%), depressor anguli oris (100% versus 46%), and mentalis (100% versus 54%) ( P < 0.05). All ink was found inside the correct target (no ink outside) in 65% using ultrasound guidance versus 29% without ( P < 0.001). Injection accuracy (any ink in target) was 100% when using ultrasound guidance versus 83% without ( P < 0.01). Twenty-three percent of the landmark-guided depressor anguli oris injections stained the facial artery ( P = 0.22). CONCLUSIONS Ultrasound guidance significantly increased injection accuracy and reduced the amount of ink lost in the surrounding tissue compared with landmark guidance. Clinical trials are needed to explore the effects of ultrasound guidance on treatment outcome, duration, and complications in patients with facial paralysis.
Collapse
Affiliation(s)
| | | | | | | | | | - Chieh-Han John Tzou
- Uppsala, Sweden; and Vienna, Austria
- From the Department of Surgical Sciences, Plastic and Maxillofacial Surgery
- Otorhinolaryngology-Head and Neck Surgery, Uppsala University
- Division of Anatomy, Medical University of Vienna
- BioImaging Austria (CMI)
- Plastic and Reconstructive Surgery, Department of Surgery, Hospital of Divine Savior (Krankenhaus Goettlicher Heiland)
- Faculty of Medicine, Sigmund Freud University
- Facial Palsy Center, Tzou Medical
- Radiology, Hanusch Hospital
| | - Lars Jonsson
- Otorhinolaryngology-Head and Neck Surgery, Uppsala University
| | - Stefan Meng
- Division of Anatomy, Medical University of Vienna
- Radiology, Hanusch Hospital
| |
Collapse
|
3
|
Mohan AS, Sullivan J, Tenenbaum MM, Broderick KB, Myckatyn TM. Toward a Consensus Aproach for Assessing Capsular Contracture Severity and Progression: A Systematic Review. Plast Reconstr Surg 2024; 153:7-22. [PMID: 37075286 PMCID: PMC10729898 DOI: 10.1097/prs.0000000000010573] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2022] [Accepted: 11/11/2022] [Indexed: 04/21/2023]
Abstract
BACKGROUND Breast implants are the most commonly used medical devices in plastic surgery, and capsular contracture (CC) is one of the most common complications. However, our assessment of CC is based largely on Baker grade, which is problematically subjective and affords only four possible values. METHODS The authors performed a systematic review concluding in September of 2021 in compliance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. It identified 19 articles that propose approaches to measuring CC. RESULTS In addition to Baker grade, the authors identified several modalities reported to measure CC. These included magnetic resonance imaging, ultrasonography, sonoelastography, mammacompliance measuring devices, applanation tonometry, histologic evaluation, and serology. Capsule thickness and other measures of CC inconsistently correlated with Baker grade, whereas the presence of synovial metaplasia was consistently associated with Baker grade I and II, but not III and IV capsules. CONCLUSIONS There remains no particular method to reliably and specifically measure the contracture of capsules that form around breast implants. As such, we would recommend that research investigators use more than one modality to measure CC. Other variables that can impact breast implant stiffness and associated discomfort beyond CC need to be considered when evaluating patient outcomes. Given the value placed on CC outcomes in assessing breast implant safety, and the prevalence of breast implants overall, the need for a more reliable approach to measuring this outcome persists.
Collapse
Affiliation(s)
- Abee S. Mohan
- From the Department of Plastic and Reconstructive Surgery, Johns Hopkins School of Medicine
| | - Janessa Sullivan
- Division of Plastic and Reconstructive Surgery, Washington University in St. Louis School of Medicine
| | - Marissa M. Tenenbaum
- Division of Plastic and Reconstructive Surgery, Washington University in St. Louis School of Medicine
| | - Kristen B. Broderick
- From the Department of Plastic and Reconstructive Surgery, Johns Hopkins School of Medicine
| | - Terence M. Myckatyn
- Division of Plastic and Reconstructive Surgery, Washington University in St. Louis School of Medicine
| |
Collapse
|
4
|
Jaeger M, Randquist C, Gahm J. Anatomical Breast Implant Assessment Using Ultrasound: A Case Series from the International Breast Implant Check Clinic. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2023; 11:e5469. [PMID: 38111726 PMCID: PMC10727634 DOI: 10.1097/gox.0000000000005469] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Accepted: 10/12/2023] [Indexed: 12/20/2023]
Abstract
Background Breast augmentation with anatomic implants can achieve a natural look, but over time, implant-related complications can occur. This includes a risk of potential rotation, which can cause a change in breast shape. Reported rates of rotation vary widely (0%-42%). Implant rotation is often detected by physical examination only or as a perioperative finding. Change in breast shape after augmentation requires clinical evaluation. In-office ultrasound allows for detailed assessment of implants for rotation and other complications. Methods Women with anatomical breast implants seeking follow-up at the International Breast Implant Check Clinic in Stockholm, Sweden, from April 2020 to July 2022 were included in the study. Using a standardized protocol, subjective symptoms were recorded, and a physical examination followed by an ultrasound assessment was performed by a single board-certified plastic surgeon (M.J.) trained in implant assessment via ultrasound. Rotation was defined as an implant rotated past 30 degrees off the breast midline at 6 o'clock. Results The study included 308 women (mean age 40.1, range 20-78) with bilateral anatomical implants. Overall, 40 women (13.0%) reported a change in breast shape; 35 had one or more implant-related complications, including five with rotation on ultrasound. Of the 308 women, 11 (3.6%) had rotations upon physical examination, and an additional 10 cases were identified using ultrasound. Conclusions Rotation is a potential complication of anatomical breast implants. However, in this study, change in breast shape was more commonly caused by other implant-related complications. Ultrasound is a valuable tool in evaluating causes of change in breast shape.
Collapse
Affiliation(s)
| | | | - Jessica Gahm
- From Victoriakliniken, Stockholm, Sweden
- Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden
| |
Collapse
|
5
|
Kehrer A, Ruewe M, Klebuc M, Platz Batista da Silva N, Lonic D, Heidkrueger P, Knoedler S, Jung EM, Prantl L, Knoedler L. Objectifying the Role of the Depressor Anguli Oris Muscle Using High-Resolution Ultrasound: A Prospective Study. Plast Reconstr Surg 2023; 152:866-870. [PMID: 36780356 DOI: 10.1097/prs.0000000000010287] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/14/2023]
Abstract
BACKGROUND In the setting of facial palsy, synkinesis of the depressor anguli oris (DAO) muscle is a common pathology, impairing dynamic and resting facial symmetry.In this prospective study, the authors used high-resolution ultrasound (HRUS) to evaluate the morphologic features of DAO and to quantify bilateral differences in DAO cross-sectional diameter (CSD) in individuals with unilateral synkinesis. METHODS From June of 2020 to May of 2021, 30 patients (19 women, 11 men) with clinically diagnosed unilateral synkinesis underwent evaluation with HRUS. DAO CSD was measured bilaterally, 1 cm inferior to the modiolus, in both the resting and smiling positions. RESULTS The Sunnybrook Facial Grading System Synkinesis Score was 6.20 ± 2.48 (range, 0 to 10). DAO CSD at rest measured 2.41 ± 0.67 mm (range, 1.40 to 4.00 mm) on the control side and 2.66 ± 0.98 mm (range, 1.60 to 5.10 mm) on the affected side. On the control side, DAO CSD was reduced by -0.19 ± 0.43 mm (range, -1.10 to 1.12 mm) during smiling. In contrast, the synkinetic DAO CSD increased by 0.64 ± 0.38 mm (range, 0.00 to 1.59 mm) ( P < 0.001) with animation. The pattern of increased CSD in synkinetic DAO muscles and decreased or unchanged CSD on the control side during smiling was identified in 70% of patients. CONCLUSIONS HRUS demonstrates increased CSD in synkinetic DAO muscles during active smiling. The opposite is true for DAO muscles on the control side, which exhibit decreased CSD with animation. HRUS can be performed preoperatively to objectify DAO dysfunction and guide targeted therapy. CLINICAL QUESTION/LEVEL OF EVIDENCE Diagnostic, IV.
Collapse
Affiliation(s)
- Andreas Kehrer
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | - Marc Ruewe
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | | | | | - Daniel Lonic
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | - Paul Heidkrueger
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | - Samuel Knoedler
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | | | - Lukas Prantl
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| | - Leonard Knoedler
- From the Departments of Plastic, Hand, and Reconstructive Surgery
| |
Collapse
|
6
|
Harutyunyan R, Gilardino MS, Papanastasiou VW, Jeffries SD, Hemmerling TM. Ultrasound Calculation of Fat Volume for Liposuction: A Clinical Software Validation. Aesthet Surg J 2023; 43:1150-1158. [PMID: 37099036 DOI: 10.1093/asj/sjad121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2022] [Revised: 04/20/2023] [Accepted: 04/21/2023] [Indexed: 04/27/2023] Open
Abstract
BACKGROUND Fat manipulation procedures such as liposuction contain a degree of subjectivity primarily guided by the surgeon's visual or tactile perception of the underlying fat. Currently, there is no cost-effective, direct method to objectively measure fat depth and volume in real time. OBJECTIVES Utilizing innovative ultrasound-based software, the authors aimed to validate fat tissue volume and distribution measurements in the preoperative setting. METHODS Eighteen participants were recruited to evaluate the accuracy of the new software. Recruited participants underwent ultrasound scans within the preoperative markings of the study area before surgery. Ultrasound-estimated fat profiles were generated with the in-house software and compared directly with the intraoperative aspirated fat recorded after gravity separation. RESULTS Participants' mean age and BMI were 47.6 (11.3) years and 25.6 (2.3) kg/m2, respectively. Evaluation of trial data showed promising results following the use of a Bland Altman agreement analysis. For the 18 patients and 44 volumes estimated, 43 of 44 measurements fell within a confidence interval of 95% when compared with the clinical lipoaspirate (dry) volumes collected postsurgery. The bias was estimated at 9.15 mL with a standard deviation of 17.08 mL and 95% confidence interval between -24.34 mL and 42.63 mL. CONCLUSIONS Preoperative fat assessment measurements agreed significantly with intraoperative lipoaspirate volumes. The pilot study demonstrates, for the first time, a novel companion tool with the prospect of supporting surgeons in surgical planning, measuring, and executing the transfer of adipose tissues. LEVEL OF EVIDENCE: 4
Collapse
|
7
|
Shabir D, Anjum A, Hamza H, Padhan J, Al-Ansari A, Yaacoub E, Mohammed A, Navkar NV. Development and Evaluation of a Mixed-Reality Tele-ultrasound System. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1867-1874. [PMID: 37263893 DOI: 10.1016/j.ultrasmedbio.2023.04.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2022] [Revised: 02/25/2023] [Accepted: 04/28/2023] [Indexed: 06/03/2023]
Abstract
OBJECTIVE The objective of this feasibility study was to develop and assess a tele-ultrasound system that would enable an expert sonographer (situated at the remote site) to provide real-time guidance to an operator (situated at the imaging site) using a mixed-reality environment. METHODS An architecture along with the operational workflow of the system is designed and a prototype is developed that enables guidance in form of audiovisual cues. The visual cues comprise holograms (of the ultrasound images and ultrasound probe) and is rendered to the operator using a head-mounted display device. The position and orientation of the ultrasound probe's hologram are remotely controlled by the expert sonographer and guide the placement of a physical ultrasound probe at the imaging site. The developed prototype was evaluated for its performance on a network. In addition, a user study (with 12 participants) was conducted to assess the operator's ability to align the probe under different guidance modes. RESULTS The network performance revealed the view of the imaging site and ultrasound images were transferred to the remote site in 233 ± 42 and 158 ± 38 ms, respectively. The expert sonographer was able to transfer, to the imaging site, data related to position and orientation of the ultrasound probe's hologram in 78 ± 13 ms. The user study indicated that the audiovisual cues are sufficient for an operator to position and orient a physical probe for accurate depiction of the targeted tissue (p < 0.001). The probe's placement translational and rotational errors were 1.4 ± 0.6 mm and 5.4 ± 2.2º. CONCLUSION The work illustrates the feasibility of using a mixed-reality environment for effective communication between an expert sonographer (ultrasound physician) and an operator. Further studies are required to determine its applicability in a clinical setting during tele-ultrasound.
Collapse
Affiliation(s)
- Dehlela Shabir
- Department of Surgery, Hamad Medical Corporation, Doha, Qatar
| | - Arshak Anjum
- Department of Computer Science and Engineering, Qatar University, Doha, Qatar
| | - Hawa Hamza
- Department of Surgery, Hamad Medical Corporation, Doha, Qatar
| | | | | | - Elias Yaacoub
- Department of Computer Science and Engineering, Qatar University, Doha, Qatar
| | - Amr Mohammed
- Department of Computer Science and Engineering, Qatar University, Doha, Qatar
| | - Nikhil V Navkar
- Department of Surgery, Hamad Medical Corporation, Doha, Qatar.
| |
Collapse
|
8
|
Swanson E. Clinical Evaluation of 310 Abdominoplasties and Measurement of Scar Level. Ann Plast Surg 2023; 91:14-27. [PMID: 37157139 PMCID: PMC10373855 DOI: 10.1097/sap.0000000000003550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 03/08/2023] [Indexed: 05/10/2023]
Abstract
BACKGROUND Most published studies on abdominoplasty focus on methods to reduce the risk of seromas. These methods include limited dissection (lipoabdominoplasty), quilting sutures, and preservation of the Scarpa fascia. Quantitative evaluation of the aesthetic result has been lacking. METHODS A retrospective study was undertaken of all patients undergoing abdominoplasty in the author's practice from 2016 to 2022. A full abdominoplasty was performed, usually with liposuction (87%). All patients were treated under total intravenous anesthesia without paralysis or prone positioning. A single closed suction drain was removed 3 or 4 days after surgery. All procedures were performed as outpatients. Ultrasound surveillance was used to detect any deep venous thromboses. No patient received chemoprophylaxis. The operating table was flexed, often to 90°. Deep fascial anchoring sutures were used to attach the Scarpa fascia of the flap to the deep muscle fascia. Measurements of the scar level were made at intervals after surgery up to 1 year. RESULTS Three hundred ten patients were evaluated, including 300 women. The mean follow-up time was 1 year. The overall complication rate, which included minor scar deformities, was 35.8%. Five deep venous thromboses were detected. There were no hematomas. Fifteen patients (4.8%) developed seromas that were successfully treated by aspiration. The mean vertical scar level 1 month after surgery was 9.9 cm (range, 6.1-12.9 cm). There was no significant change in scar level at subsequent follow-up times up to 1 year. By comparison, the scar level in published studies ranged from 8.6 to 14.1 cm. DISCUSSION Avoidance of electrodissection reduces tissue trauma that causes seromas. Flexed patient positioning during surgery and deep fascial anchoring sutures are effective in keeping the scar low. By avoiding chemoprophylaxis, hematomas can be avoided. Limiting the dissection (lipoabdominoplasty), preserving the Scarpa fascia, and adding quilting (progressive tension) sutures are unnecessary. CONCLUSIONS Total intravenous anesthesia offers important safety advantages. Avoiding electrodissection is effective in keeping seroma rates at a tolerable level (5%), and the scar low and more easily concealed. Alternative methods present disadvantages that may contribute to a suboptimal aesthetic result and require additional operating time.
Collapse
Affiliation(s)
- Eric Swanson
- Dr Swanson is a plastic surgeon in private practice in Leawood, KS
| |
Collapse
|
9
|
Swanson E. Abandoning Caprini Scores and Chemoprophylaxis ("Bloodletting 2.0"): A Call for Action. Ann Plast Surg 2023; 91:2-7. [PMID: 37254249 PMCID: PMC10373844 DOI: 10.1097/sap.0000000000003565] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Accepted: 03/18/2023] [Indexed: 06/01/2023]
|
10
|
Harutyunyan R, Gilardino MS, Wu Y, Jeffries SD, Hemmerling TM. Description of a Novel Web-Based Liposuction System to Estimate Fat Volume and Distribution. Aesthet Surg J 2022; 43:582-592. [PMID: 36446744 DOI: 10.1093/asj/sjac307] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 11/10/2022] [Accepted: 11/10/2022] [Indexed: 12/05/2022] Open
Abstract
BACKGROUND Pre-operative planning for liposuction is vital to ensure safe practice and patient satisfaction. However, current standards of fat assessment before surgery are guided by subjective methods such as visual inspection, skin-pinch tests, and waist circumference measurements. OBJECTIVES This study aimed to develop an inexpensive software-based tool that utilizes ultrasound (US) imaging and an online platform to accurately simulate regional subcutaneous adipose tissue (SAT) distribution and safe volume estimation for liposuction procedures. METHODS The authors present a web-based platform with integrated two-dimensional (2D) and three-dimensional (3D) simulations of SAT to support liposuction planning and execution. SAT-Map was constructed using multiple sub-applications linked with the python framework programming language (Wilmington, DE). RESULTS The SAT-Map interface provides an intuitive and fluid means of generating patient-specific models and volumetric data. To further accommodate this, an operational manual was prepared to achieve consistent visualization and examination of estimated SAT content. The system currently supports static 2D heatmap simulation and 3D interactive virtual modelling of the SAT distribution. Supplementary clinical studies are needed to evaluate SAT-Map's clinical performance and practicality. CONCLUSIONS SAT-Map revolutionizes the concept of pre-operative planning for liposuction by developing the first combined web-based software that objectively simulates fat distribution and measures safe liposuction volume. Our software approach presents a cost-efficient, accessible, and user-friendly system offering multiple advantages over current SAT assessment modalities. The immediacy of clinically accurate 3D virtual simulation provides objective support to surgeons towards improving patient conversation, outcomes, and satisfaction in liposuction procedures.
Collapse
Affiliation(s)
- Robert Harutyunyan
- Department of Experimental Surgery, McGill University Health Center; Montreal, QC, Canada
| | - Mirko S Gilardino
- Chief, Division of Plastic and Reconstructive Surgery, McGill University Health Center; Montreal, QC, Canada
| | - Yichen Wu
- Undergraduate student, Department of Electrical and Computer Engineering, McGill University; Montreal, QC, Canada
| | - Sean D Jeffries
- Department of Experimental Surgery, McGill University Health Center; Montreal, QC, Canada
| | - Thomas M Hemmerling
- Department of Experimental Surgery, McGill University Health Center; Montreal, QC, Canada
| |
Collapse
|
11
|
Mortada H, Al Mazrou F, Alghareeb A, AlEnezi M, Alalawi S, Neel OF. Overview of the role of ultrasound imaging applications in plastic and reconstructive surgery: is ultrasound imaging the stethoscope of a plastic surgeon? A narrative review of the literature. EUROPEAN JOURNAL OF PLASTIC SURGERY 2022. [DOI: 10.1007/s00238-022-01981-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
|
12
|
Nassar AH, Maselli AM, Manstein S, Shiah E, Slatnick BL, Dowlatshahi AS, Cauley R, Lee BT. Comparison of Various Modalities Utilized for Preoperative Planning in Microsurgical Reconstructive Surgery. J Reconstr Microsurg 2021; 38:170-180. [PMID: 34688218 DOI: 10.1055/s-0041-1736316] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
BACKGROUND The benefits of preoperative perforator imaging for microsurgical reconstruction have been well established in the literature. METHODS An extensive literature review was performed to determine the most commonly used modalities, and their applicability, advantages and disadvantages. RESULTS The review demonstrated varioius findings including decreases in operative time and cost with the use of CT angiography to identification of perforators for inclusion in flap design with hand-held Doppler ultrasound. Modalities like MR angiography offer alternatives for patients with contrast allergies or renal dysfunction while maintaining a high level of clarity and fidelity. Although the use of conventional angiography has decreased due to the availability of less invasive alternatives, it continues to serve a role in the preoperative evaluation of patients for lower extremity reconstruction. Duplex ultrasonography has been of great interest recently as an inexpensive, risk free, and extraordinarily accurate diagnostic tool. Emerging technologies such as indocyanine green fluorescence angiography and dynamic infrared thermography provide real-time information about tissue vascularity and perfusion without requiring radiation exposure. CONCLUSION This article presents an in-depth review of the various imaging modalities available to reconstructive surgeons and includes hand held Doppler ultrasound, CT angiography, MR angiography, conventional angiography, duplex ultrasonography, Indocyanine Green Fluorescence Angiography and Dynamic Infrared Thermography.
Collapse
Affiliation(s)
- Amer H Nassar
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Amy M Maselli
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Samuel Manstein
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Eric Shiah
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Brianna L Slatnick
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,Department of Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts
| | - Arriyan S Dowlatshahi
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts.,Department of Orthopedic Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Ryan Cauley
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| | - Bernard T Lee
- Division of Plastic and Reconstructive Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
13
|
Reconsidering the Role of Routine Anticoagulation for Venous Thromboembolism Prevention in Plastic Surgery. Ann Plast Surg 2021; 85:97-99. [PMID: 31809477 PMCID: PMC7363439 DOI: 10.1097/sap.0000000000002162] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
14
|
Swanson E. Ultrasound Surveillance Offers a Safe and Effective Method for Venous Thromboembolism Prevention in Plastic Surgery Patients. Aesthetic Plast Surg 2020; 44:2335-2339. [PMID: 32869134 PMCID: PMC7683443 DOI: 10.1007/s00266-020-01935-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 08/23/2020] [Indexed: 11/30/2022]
|
15
|
Prospective Study of Saline versus Silicone Gel Implants for Subpectoral Breast Augmentation. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2020; 8:e2882. [PMID: 32766047 PMCID: PMC7339341 DOI: 10.1097/gox.0000000000002882] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Accepted: 04/08/2020] [Indexed: 11/25/2022]
Abstract
Background Silicone gel implants are regarded as esthetically superior to saline implants, offering a more natural consistency. They are also considered less susceptible to rippling. However, objective measurements and patient-reported outcome studies are lacking. Similarly, minimal data are available quantitating animation deformity. Methods A 3-year prospective study was undertaken among 223 women undergoing primary subpectoral breast augmentation using either saline (n = 145) or silicone gel (n = 78) implants. Photographs obtained included frontal views with the patient flexing the pectoral muscles. Images were matched, and vertical differences in nipple position were measured. Breast implants were evaluated using high-resolution ultrasound to detect any ripples or folds at least 3 months after surgery. Outcome surveys were administered. Statistical analysis included the χ2 test, point-biserial correlations, and a power analysis. Results Respondents reported visible rippling in 18% of women and palpable rippling in 32% of patients, with no significant difference between women treated with saline and silicone gel implants. Ripples were detected on ultrasound scans in 24% of women with saline implants and in 27% of women with silicone gel implants (difference not significant). Ripples were more common in women with lower body mass indices. Fifty percent of patients demonstrated nipple displacement <1 cm on animation. Nipple displacement occurred either up or down with equal frequency and a mean overall nipple displacement of zero. Conclusions Saline and silicone breast implants produce similar degrees of rippling, as determined on outcome surveys and ultrasound examination. Animation deformities tend to be minor and well-tolerated.
Collapse
|
16
|
Inadvertent Rupture of a Silicone Breast Implant during Fat Grafting: Surgical and Radiological Findings. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2020; 8:e2863. [PMID: 32766036 PMCID: PMC7339351 DOI: 10.1097/gox.0000000000002863] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Accepted: 03/26/2020] [Indexed: 11/25/2022]
Abstract
Autologous fat grafting is a common, relatively safe procedure for breast augmentation and reconstruction. The most commonly reported complications tend to be fat necrosis and oil cysts. The incidence of rare events, such as breast implant rupture, is likely underreported. Here we present the case of a patient who underwent fat grafting and sustained implant rupture with injection of fat within the silicone implant. She complained of her implant changing shape and magnetic resonance imaging (MRI) showed classic signs of implant rupture (linguini sign). At the time of surgery however, fat was surprisingly found to be within the implant itself. To our knowledge this finding has yet to be reported. Here we review the radiologic and surgical findings of implant rupture following fat grafting and present some suggestions to prevent this occurrence and ensure safe, aesthetically pleasing outcomes.
Collapse
|
17
|
The Effect of Sequential Compression Devices on Fibrinolysis in Plastic Surgery Outpatients: A Randomized Trial. Plast Reconstr Surg 2020; 145:392-401. [PMID: 31985629 DOI: 10.1097/prs.0000000000006464] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Sequential compression devices are often considered a mainstay of prophylaxis against deep venous thromboses in surgical patients. The devices are believed to produce a milking action on the deep veins to prevent venous stasis. A systemic fibrinolytic effect has also been proposed, adding a second mechanism of action. The plasma levels of tissue plasminogen activator and plasminogen activator inhibitor-1 reflect fibrinolytic activity. METHODS A randomized trial was conducted among 50 consecutive plastic surgery outpatients undergoing cosmetic surgery performed by the author under total intravenous anesthesia and without paralysis. Patients were randomized to receive calf-length sequential compression devices or no sequential compression devices during surgery. Blood samples were obtained from the upper extremity preoperatively and at hourly intervals until the patient was discharged from the postanesthesia care unit. Tissue plasminogen activator and plasminogen activator inhibitor-1 levels were measured. Ultrasound surveillance was used in all patients. There was no outside funding for the study. RESULTS All patients agreed to participate (inclusion rate, 100 percent). No patient developed clinical signs or ultrasound evidence of a deep venous thrombosis. There were no significant changes in tissue plasminogen activator levels or plasminogen activator inhibitor-1 levels from the preoperative measurements at any hourly interval and no differences in levels comparing patients treated with or without sequential compression devices. CONCLUSIONS No significant change in systemic fibrinolytic activity occurs during outpatient plastic surgery under total intravenous anesthesia. Sequential compression devices do not affect tissue plasminogen activator or plasminogen activator inhibitor-1 levels, suggesting no fibrinolytic benefit. CLINICAL QUESTION/LEVEL OF EVIDENCE Therapeutic, I.
Collapse
|
18
|
Prospective Study of Doppler Ultrasound Surveillance for Deep Venous Thromboses in 1000 Plastic Surgery Outpatients. Plast Reconstr Surg 2020; 145:85-96. [DOI: 10.1097/prs.0000000000006343] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Near-circumferential Lower Body Lift: A Review of 40 Outpatient Procedures. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2019; 7:e2548. [PMID: 32537298 PMCID: PMC7288879 DOI: 10.1097/gox.0000000000002548] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2019] [Accepted: 10/04/2019] [Indexed: 12/16/2022]
Abstract
Lower body lift surgery has increased in popularity. A circumferential body lift or belt lipectomy is often recommended to treat skin redundancy. A drawback for this procedure is the midline scar bridging the lower back causing elongation of the gluteal cleft. Autoaugmentation methods have not been shown to provide a net increase in buttock volume.
Collapse
|
20
|
Spotlight in Plastic Surgery. Plast Reconstr Surg 2019. [DOI: 10.1097/prs.0000000000005517] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|