• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (5140102)   Today's Articles (2474)
For: Choi SH, Lee EK, Nam KY, Kim JY. Fibrin Glue-Assisted Conjunctival Closure in Pars Plana Vitrectomy Where Conjunctival Closure With a Suture Would Be Difficult. Retina 2010;30:688-91. [DOI: 10.1097/iae.0b013e3181cdf398] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Number Cited by Other Article(s)
1
López-Guajardo L, Benítez-Herreros J, Donate-López J, Opazo-Toro V. Evaluation of leakage resistance improvement in transconjunctival sutureless vitrectomy sclerotomies closed with adhesives. an experimental study. Eye (Lond) 2019;34:1229-1234. [PMID: 31685969 PMCID: PMC7314807 DOI: 10.1038/s41433-019-0651-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2019] [Revised: 08/15/2019] [Accepted: 10/13/2019] [Indexed: 01/25/2023]  Open
2
Edwards SJ, Crawford F, van Velthoven MH, Berardi A, Osei-Assibey G, Bacelar M, Salih F, Wakefield V. The use of fibrin sealant during non-emergency surgery: a systematic review of evidence of benefits and harms. Health Technol Assess 2016;20:1-224. [PMID: 28051764 PMCID: PMC5292645 DOI: 10.3310/hta20940] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]  Open
3
Subconjunctival Injection of Viscoelastic Material for Leaking Sclerotomy in Transconjunctival Sutureless Vitrectomy. J Ophthalmol 2016;2016:9659675. [PMID: 27144018 PMCID: PMC4837269 DOI: 10.1155/2016/9659675] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2016] [Accepted: 03/29/2016] [Indexed: 11/17/2022]  Open
4
Ho VY, Shah GK, Liu EM. ReSure Sealant for Pars Plana Vitrectomy Wound Closure. Ophthalmic Surg Lasers Imaging Retina 2015;46:1042-4. [DOI: 10.3928/23258160-20151027-09] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2015] [Accepted: 09/24/2015] [Indexed: 11/20/2022]
5
Nugent RB, Lee GA. Ophthalmic use of blood-derived products. Surv Ophthalmol 2015;60:406-34. [PMID: 26077627 DOI: 10.1016/j.survophthal.2015.03.003] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2014] [Revised: 03/23/2015] [Accepted: 03/25/2015] [Indexed: 12/23/2022]
PrevPage 1 of 1 1Next
© 2004-2025 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA