1
|
Hoogewerf M, Schuurkamp J, Kelder JC, Jacobs S, Doevendans PA. Sutureless versus Hand-Sewn Coronary Anastomoses: A Systematic Review and Meta-Analysis. J Clin Med 2022; 11:749. [PMID: 35160201 PMCID: PMC8837108 DOI: 10.3390/jcm11030749] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/21/2022] [Accepted: 01/26/2022] [Indexed: 02/05/2023] Open
Abstract
BACKGROUND Sutureless coronary anastomotic devices are intended to facilitate minimally invasive coronary artery bypass grafting (MICS-CABG) by easing and eventually standardizing the anastomotic technique. Within this systematic review and meta-analysis, we aim to determine patency and to evaluate safety outcomes for the sutureless anastomoses. METHODS CENTRAL, MEDLINE, and EMBASE were searched from database start till August 2021 in a predefined search strategy combining the key concepts: 'coronary artery bypass grafting', 'sutureless coronary anastomoses', and 'hand-sewn coronary anastomoses' by the Boolean operation 'AND'. Study characteristics, patient demographics, interventional details, and all available outcome data were extracted. A meta-analysis was performed on patency at longest follow-up. Safety outcomes were presented. RESULTS A total of eleven trials towards six sutureless anastomotic devices were included, comprising 3724 patients (490 sutureless and 3234 hand-sewn). There was no significant difference in patency at a mean follow-up duration of 546.3 (range 1.5-2691) days, with a risk ratio of 0.77 (95% CI 0.55-1.06). MACE was reported in 4.5% sutureless and 3.9% hand-sewn patients, including all-cause mortality (resp. 1.3 vs. 1.9%), myocardial infarction (resp. 1.6 vs. 1.7%), and coronary revascularization (resp. 1.8 vs. 0.5%). Incomplete hemostasis occurred in 24.8% of the sutureless anastomoses. Intra-operative device failure forced conversion to hand-sewn or redo-anastomosis in 5.8% of the sutureless cases. CONCLUSION Based on the systematic review and meta-analysis including six devices, we conclude that sutureless coronary anastomotic devices appear safe and effective when used by well-trained and dedicated surgical teams.
Collapse
Affiliation(s)
- Marieke Hoogewerf
- Department of Cardiology, University Medical Centre Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.); (P.A.D.)
- Department of Cardiothoracic Surgery, St. Antonius Hospital, 3435 CM Nieuwegein, The Netherlands
| | - Jeroen Schuurkamp
- Department of Cardiology, University Medical Centre Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.); (P.A.D.)
| | - Johannes C. Kelder
- Department of Cardiology, St. Antonius Hospital, 3435 CM Nieuwegein, The Netherlands;
| | - Stephan Jacobs
- Department of Cardiothoracic and Vascular Surgery, German Heart Centre Berlin, 13353 Berlin, Germany;
| | - Pieter A. Doevendans
- Department of Cardiology, University Medical Centre Utrecht, 3584 CX Utrecht, The Netherlands; (J.S.); (P.A.D.)
- Netherlands Heart Institute, 3511 EP Utrecht, The Netherlands
- Central Military Hospital, 3584 EZ Utrecht, The Netherlands
| |
Collapse
|
2
|
Balkhy HH, Nisivaco SM, Hashimoto M, Torregrossa G, Grady K. Robotic Total Endoscopic Coronary Bypass in 570 Patients: Impact of Anastomotic Technique in 2 Eras. Ann Thorac Surg 2021; 114:476-482. [PMID: 34890572 DOI: 10.1016/j.athoracsur.2021.10.049] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/17/2021] [Revised: 09/21/2021] [Accepted: 10/07/2021] [Indexed: 11/20/2022]
Abstract
BACKGROUND In coronary bypass grafting, including robotic off-pump totally-endoscopic coronary bypass (TECAB), the anastomotic technique is the most critical part of the procedure. We reviewed results in 570 patients over a 7-year period and compared outcomes between to eras, based on predominant anastomotic technique: connectors versus running suture. METHODS Between 7/2013-12/2020, 570 patients underwent off-pump TECAB. Group-1 (378 patients, 7/2013-8/2018) using predominantly the C-Port Flex ATM distal anastomotic stapler (Aesculap, Tuttlingen Germany), Group-2 (192 patients, 9/2018-12/2020) using predominantly a sutured technique (7-0 PronovaTM, Johnson and Johnson, USA). Retrospective analysis of clinical outcomes was performed. RESULTS Off-pump TECAB was completed in 98.8% (563/570 patients) with an Observed/Expected mortality of 0.6 (6/570 patients). The anastomotic device was used in 89% of 626 grafts in Group-1 and only 11% of 305 grafts in Group-2 (p=0.001). There were no differences in multivessel TECAB (57%vs.53%;p=0.331) or bilateral internal thoracic artery use (50%vs.43%;p=0.127) in Group-1 vs Group-2, respectively. Operative time was shorter in Group-1 (242+84 min vs. 273+88 min;p<0.001). Early clinical outcomes were similar between groups, except for hospital stay which was longer in Group-1 (2.9vs2.3 days;p<0.001). Graft patency was similar (98%vs95%;p=0.295) in Group-1 vs Group-2, respectively. CONCLUSIONS Changing the predominant approach from stapled anastomosis to a sutured technique during robotic TECAB resulted in longer operative times. Both approaches led to excellent outcomes, including graft patency. The shorter operative times conferred by using staplers may flatten the learning curve and facilitate broader adoption of TECAB.
Collapse
Affiliation(s)
- Husam H Balkhy
- Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, Illinois.
| | - Sarah M Nisivaco
- Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, Illinois
| | - Makoto Hashimoto
- Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, Illinois
| | - Gianluca Torregrossa
- Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, Illinois
| | - Kaitlin Grady
- Department of Cardiothoracic Surgery, University of Chicago Medicine, Chicago, Illinois
| |
Collapse
|
3
|
Stecher D, Hoogewerf M, Bronkers G, van Putte BP, Doevendans PA, Tulleken CAF, van Herwerden L, Pasterkamp G, Buijsrogge MP. Preclinical Feasibility and Patency Analyses of a New Distal Coronary Connector: The ELANA Heart Bypass. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2021; 16:163-168. [PMID: 33682510 PMCID: PMC8108114 DOI: 10.1177/1556984521991519] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Objective This preclinical study determines the feasibility and 6-month patency rates of a new distal coronary connector, the Excimer Laser Assisted Nonocclusive Anastomosis (ELANA) Heart Bypass. Methods Twenty Dutch Landrace pigs received either a hand-sewn (n = 8) or an ELANA (n = 12) left internal thoracic artery to left anterior descending artery anastomosis, using off-pump coronary artery bypass grafting. Six-month patency rates were demonstrated by coronary angiography and histological evaluation. Throughout, procedural details and complication rates were collected. Results The ELANA Heart Bypass demonstrated 0% mortality and complication rates during follow-up. It was demonstrated feasible, with comparable perioperative flow measurements (ELANA vs hand-sewn, median [min to max], 24 [14 to 28] vs 17 [12 to 31] mL/min; P = 0.601) and fast construction times (3 [3 to 7] vs 31 [26 to 37] min; P < 0.001). Yet, an extra hemostatic stitch was needed in 25% of the ELANA versus 12.5% of the hand-sewn anastomoses. The 6-month patency rate of the ELANA Heart Bypass was 83.3% versus 100% in hand-sewn anastomoses. The 2 occluded ELANA-anastomoses were defined model-based errors. Conclusions The ELANA Heart Bypass facilitates a sutureless distal coronary anastomosis. A design change is suggested to improve hemostasis and will be evaluated in future translational studies. This new technique is a potential alternative to hand-sewn anastomoses in (minimally invasive) coronary surgery.
Collapse
Affiliation(s)
- David Stecher
- 8124 Department of Cardiothoracic Surgery, University Medical Center Utrecht, The Netherlands
| | - Marieke Hoogewerf
- 8124 Department of Cardiology, University Medical Center Utrecht, The Netherlands.,AMT Medical Research B.V., Utrecht, The Netherlands
| | | | - Bart P van Putte
- 6028 Department of Cardiothoracic Surgery, St. Antonius Hospital, Nieuwegein, The Netherlands.,Department of Cardiothoracic Surgery, Amsterdam University Medical Center, The Netherlands
| | - Pieter A Doevendans
- 8124 Department of Cardiology, University Medical Center Utrecht, The Netherlands.,Netherlands Heart Institute, Utrecht, The Netherlands
| | - Cornelis A F Tulleken
- AMT Medical Research B.V., Utrecht, The Netherlands.,8124 Department of Neurosurgery, University Medical Center Utrecht, The Netherlands
| | - Lex van Herwerden
- 8124 Department of Cardiothoracic Surgery, University Medical Center Utrecht, The Netherlands
| | - Gerard Pasterkamp
- 8124 Department of Experimental Cardiology, University Medical Center Utrecht, The Netherlands
| | - Marc P Buijsrogge
- 8124 Department of Cardiothoracic Surgery, University Medical Center Utrecht, The Netherlands
| |
Collapse
|
4
|
Balkhy HH, Nathan S, Torregrossa G, Kitahara H, Nisivaco S, McCrorey M, Patel B. Angiographic patency after robotic beating heart totally endoscopic coronary artery bypass grafting facilitated by automated distal anastomotic connectors. Interact Cardiovasc Thorac Surg 2020; 31:467-474. [PMID: 33091933 DOI: 10.1093/icvts/ivaa149] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2020] [Revised: 06/17/2020] [Accepted: 07/01/2020] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES Robotic totally endoscopic coronary artery bypass (TECAB) on the beating heart has been facilitated in our experience using distal coronary anastomotic connectors. In this study, we retrospectively reviewed graft patency in all robotic TECAB patients who underwent formal angiography at our current institution over a 5-year period. METHODS Between July 2013 and June 2018, 361 consecutive patients underwent robotic beating-heart TECAB. Of these patients, 121 had a follow-up angiogram, which assessed graft patency. Eighty-four patients had an angiogram as part of planned hybrid procedures and 37 patients underwent an unplanned angiogram for clinical indications. Retrospective analysis of angiographic patency and clinical outcomes was performed. RESULTS The mean Society of Thoracic Surgeons predicted risk of mortality was 1.8%. Single-vessel bypass was performed in 40 (33%) patients and multivessel grafting in 81 (67%). Average flow (ml/min) and pulsatility index in the grafts was 74.7 ± 39.1 and 1.42 ± 0.52, respectively. The number of grafts evaluated was 204 (130 left internal mammary artery and 74 right internal mammary artery grafts). The median time to angiography was 1.0 and 16.0 months and graft patency was 98% and 91% in the hybrid and non-hybrid groups, respectively. Overall graft patency was 95.6% (left internal mammary artery = 96%; right internal mammary artery = 93%). Left internal mammary artery to left anterior descending artery graft patency was 97%. Clinical follow-up was available for 316 (88%) patients at mean 22.5 ± 15.1 months. Freedom from major adverse cardiac events at 2 years was 92%. CONCLUSIONS In this consecutive series of patients undergoing formal angiography after robotic single and multivessel TECAB, we found satisfactory graft patency and 2-year clinical outcomes. Longer-term follow-up is warranted.
Collapse
Affiliation(s)
- Husam H Balkhy
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| | - Sandeep Nathan
- Division of Cardiology, Department of Medicine, The University of Chicago Medicine, Chicago, IL, USA
| | - Gianluca Torregrossa
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| | - Hiroto Kitahara
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| | - Sarah Nisivaco
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| | - Mackenzie McCrorey
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| | - Brooke Patel
- Section of Cardiothoracic Surgery, Department of Cardiothoracic Surgery, The University of Chicago Medicine, Chicago, IL, USA
| |
Collapse
|
5
|
Robotic Multivessel Endoscopic Coronary Bypass: Impact of a Beating-Heart Approach With Connectors. Ann Thorac Surg 2019; 108:67-73. [DOI: 10.1016/j.athoracsur.2018.12.044] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Revised: 11/17/2018] [Accepted: 12/17/2018] [Indexed: 11/19/2022]
|
6
|
Balkhy HH, Patel NC, Ramshandani M, Kitahara H, Subramanian VA, Augelli NV, Tobler G, Cai TH. Multicenter Assessment of Grafts in Coronaries: Midterm Evaluation of the C-Port Device (the MAGIC Study). INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2018; 13:273-281. [PMID: 30142111 DOI: 10.1097/imi.0000000000000533] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVE The commercially available C-Port distal anastomotic device (Food and Drug Administration cleared in 2007) is an automated miniature vascular stapler that performs the coronary anastomosis. This prospective multicenter registry sought to evaluate midterm patency using this device compared with hand-sewn grafts. METHODS Patients receiving at least one C-Port anastomosis during coronary artery bypass grafting surgery were enrolled at eight sites. Of the 117 patients enrolled, 78 patients (67%) with 104 C-Port vein grafts completed the study to patency assessment via computed tomography angiography. Clinical follow-up and index graft patency (Gated 64-slice computed tomography scan) were performed at least 12 months postoperatively. The primary efficacy endpoint was patency compared with the peer-reviewed results from the PRoject of Ex-vivo Vein graft ENgineering via Transfection IV (PREVENT IV) trial. RESULTS The patient population was consistent with the PREVENT IV placebo cohort. The mortality at 12 months was 0.85% (1/117). The major cardiac morbidity rate was 3.4% (4/117). The C-Port vein graft occlusion rate was 16.3% (17/104) compared with 26.6% (597/2242) in the PREVENT IV trial (P = 0.011). Within this study, C-Port graft occlusion rates were not significantly different from the hand-sewn grafts (P = 0.821). CONCLUSIONS The C-Port device is safe and effective in creating the distal anastomosis with equivalent patency rates to hand-sewn grafts at 12 months. When compared with hand-sewn anastomoses from a recent large prospective trial, the C-Port device demonstrated a statistically significant reduction in midterm graft occlusion. Further studies are required to evaluate its effect in less invasive coronary surgery.
Collapse
Affiliation(s)
| | - Nirav C Patel
- Department of Cardiac Surgery, Lenox Hill Hospital, New York, NY USA
| | - Mahesh Ramshandani
- Department of Cardiothoracic Surgery, Houston Methodist Hospital, Houston, TX USA
| | | | | | - Nicholas V Augelli
- Department of Cardiac Surgery, ThedaCare Regional Medical Center, Appleton, WI USA
| | - Gareth Tobler
- Department of Cardiothoracic Surgery, John L. McClellan Veterans Administration Medical Center, Little Rock, AR USA
| | - Tung H Cai
- Department of Cardiothoracic Surgery, CRSTI Heart Hospital, Plano, TX USA
| | | |
Collapse
|
7
|
Soylu E, Harling L, Ashrafian H, Rao C, Casula R, Athanasiou T. A systematic review of the safety and efficacy of distal coronary artery anastomotic devices. Eur J Cardiothorac Surg 2015; 49:732-45. [PMID: 26017016 DOI: 10.1093/ejcts/ezv179] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2015] [Accepted: 04/13/2015] [Indexed: 01/04/2023] Open
Abstract
Interest in minimally invasive and off-pump cardiac surgical techniques has promoted the development of automated distal anastomotic devices (DADs) to facilitate construction of coronary artery anastomosis. Several DADs have been proposed for potential use in coronary surgery. However, a number of technical failures and uncertainty around both short-term morbidity and long-term patency have limited the generalized uptake of these devices. A systematic literature search identified 28 studies, incorporating 970 patients who underwent coronary artery bypass grafting using a DAD. Eight different devices were identified including Heartflo, St Jude, U-clip, vessel closure system, C-port, magnetic vascular positioner and coronary anastomosis coupler. Thirty-day mortality, cardiac-specific mortality and myocardial infarction were equal between DADs and hand-sewn cases (1.3, 0.3 and 0.8%, respectively). The overall proportion of postoperative haemorrhage was higher in the anastomotic device group (2.3%) than in the group with hand-sewn anastomoses (1.5%) although not statistically significant. Overall graft patency was 97.2% at <1 month, 94.6% at 1-3 months and 92.3% at >3 months. Of the currently available systems, the U-clip device was found to provide the best overall postoperative outcomes, which included a patency of 96.1% at >3months. The current literature is limited by its predominantly observational study design and lack of directly comparative studies. Furthermore, inter-study variation in patient selection, anticoagulation strategies and follow-up periods prevents quantitative comparison. Future research necessitates multicentre randomized, controlled studies to provide a direct comparison of current and future anastomotic device systems with established hand-sewn techniques in both the short and long term.
Collapse
Affiliation(s)
- Erdinc Soylu
- Department of Surgery and Cancer, Imperial College, London, UK
| | - Leanne Harling
- Department of Surgery and Cancer, Imperial College, London, UK
| | - Hutan Ashrafian
- Department of Surgery and Cancer, Imperial College, London, UK
| | - Christopher Rao
- Department of Surgery and Cancer, Imperial College, London, UK
| | - Roberto Casula
- Department of Surgery and Cancer, Imperial College, London, UK
| | | |
Collapse
|
8
|
Verberkmoes NJ, Wolters SL, Post JC, Soliman-Hamad MA, ter Woorst JF, Berreklouw E. Distal anastomotic patency of the Cardica C-PORT(R) xA system versus the hand-sewn technique: a prospective randomized controlled study in patients undergoing coronary artery bypass grafting. Eur J Cardiothorac Surg 2013; 44:512-8; discussion 518-9. [PMID: 23435521 DOI: 10.1093/ejcts/ezt079] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
OBJECTIVES The C-Port® Distal Anastomosis Systems (Cardica, Inc., Redwood City, CA, USA) demonstrated favourable results in feasibility trials. However, distal vein anastomoses created with the C-Port® or C-Port xA® system have never been compared with hand-sewn distal vein anastomoses. The objective of this study was to compare distal end-to-side anastomoses facilitated with the C-Port xA® System with the traditional hand-sewn method. METHODS This single-centre prospective randomized controlled study comprised 71 patients (device group n = 35, control group n = 36) who underwent primary elective coronary artery bypass grafting between June 2008 and April 2011. The primary study end-point was 12-month distal anastomotic patency, which was assessed with prospective ECG-gated 256-multislice computed tomographic coronary angiography using a step-and-shoot scanning protocol. For the primary end-point, a per-protocol analysis was used. RESULTS In the device group, four (11%) anastomoses were converted to hand-sewn anastomoses, and additional stitches to achieve haemostasis were necessary in 22 (76%) patients. There was no hospital mortality in either group. During the 12-month follow-up, a single death occurred in the Device group and was unrelated to the device. Twenty-nine patients in the device group and 32 in the control group completed 12-month CT coronary angiography. The overall patency of 160 studied distal vein graft anastomoses was 93%. Comparison of the end-to-side target anastomosis showed 12-month patencies of 86 and 88% in the device group and the control group, respectively. CONCLUSIONS According to these preliminary results and despite the limited number of patients, the use of the C-Port xA® System is safe enough to perform distal end-to-side vein graft anastomosis, with respect to 12-month end-to-side distal venous anastomotic patency. Although there are some technical challenges with this device, the incidence of complications is comparable to the traditional hand-sewn technique.
Collapse
Affiliation(s)
- Niels J Verberkmoes
- Department of Cardio-Thoracic Surgery, Catharina Hospital, Eindhoven, The Netherlands.
| | | | | | | | | | | |
Collapse
|
9
|
Hillis LD, Smith PK, Anderson JL, Bittl JA, Bridges CR, Byrne JG, Cigarroa JE, Disesa VJ, Hiratzka LF, Hutter AM, Jessen ME, Keeley EC, Lahey SJ, Lange RA, London MJ, Mack MJ, Patel MR, Puskas JD, Sabik JF, Selnes O, Shahian DM, Trost JC, Winniford MD. 2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery. A report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Developed in collaboration with the American Association for Thoracic Surgery, Society of Cardiovascular Anesthesiologists, and Society of Thoracic Surgeons. J Am Coll Cardiol 2011; 58:e123-210. [PMID: 22070836 DOI: 10.1016/j.jacc.2011.08.009] [Citation(s) in RCA: 582] [Impact Index Per Article: 41.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
10
|
Hillis LD, Smith PK, Anderson JL, Bittl JA, Bridges CR, Byrne JG, Cigarroa JE, Disesa VJ, Hiratzka LF, Hutter AM, Jessen ME, Keeley EC, Lahey SJ, Lange RA, London MJ, Mack MJ, Patel MR, Puskas JD, Sabik JF, Selnes O, Shahian DM, Trost JC, Winniford MD, Winniford MD. 2011 ACCF/AHA Guideline for Coronary Artery Bypass Graft Surgery: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines. Circulation 2011; 124:e652-735. [PMID: 22064599 DOI: 10.1161/cir.0b013e31823c074e] [Citation(s) in RCA: 390] [Impact Index Per Article: 27.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
11
|
Early Patency Evaluation of New Distal Anastomotic Device in Internal Mammary Artery Grafts Using Computed Tomography Angiography. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2010; 5:109-13. [DOI: 10.1097/imi.0b013e3181d714ba] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Introduction Traditional coronary artery bypass grafting is performed using a hand sewn technique. The C-Port xA and Flex A anastomotic stapling devices (Cardica Inc., Redwood City, CA) were cleared by the Food and Drug Administration for use in distal coronary anastomoses in November 2006 and April 2007, respectively. They provide the ability to create a compliant, consistently reproducible, and automated anastomosis. Multidetector computed tomography (CT) has been shown to be effective in evaluating coronary artery bypass graft patency. Methods The first 24 patients to undergo internal mammary artery (IMA) anastomosis using the automated device in our practice were included in the study. Twenty-five IMA grafts (24 left IMA and 1 right IMA) were created using the C-Port xA or Flex A anastomotic device as part of multivessel off-pump coronary revascularization by sternotomy. Graft patency was evaluated at 30 days in the first 10 grafts and at 90 days in the next 15 grafts using multidetector (64 slice) CT. Results There were no device failures. There were no perioperative strokes, myocardial infarctions, or deaths. All 10 IMA grafts evaluated at 30 days were patent using multidetector CT. One of the 15 IMA grafts studied at 90 days was occluded using multidetector computed tomography. Conclusions The C-Port xA and Flex A distal anastomotic devices provided a safe and effective means to create a left IMA-left anterior descending artery anastomoses in coronary bypass surgery with excellent short to midterm patency in this early experience. Long-term follow-up is warranted. These findings will have important implications for future sternal sparing coronary bypass surgery.
Collapse
|
12
|
The Current Status of Anastomotic Devices for Coronary Artery Bypass Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2009; 4:9-12. [DOI: 10.1097/imi.0b013e318198dc6d] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The purpose of this article is to briefly review the history of proximal and distal anastomotic devices and to discuss presently available devices. Clinical outcome data from the EPIC Trial of the Cardica PAS-Port Proximal Anastomosis System will also be presented.
Collapse
|
13
|
Puskas JD. The Current Status of Anastomotic Devices for Coronary Artery Bypass Surgery. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY 2009. [DOI: 10.1177/155698450900400103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Affiliation(s)
- John D. Puskas
- Division of Cardiothoracic Surgery, Clinical Research Unit, Emory University School of Medicine, Atlanta, GA
| |
Collapse
|