1
|
Spencer BL, Shaikh N, Gudex L, Dann T, Langley M, Matich H, Bartlett RH, Rojas A, Potkay JA. In Vivo Testing of an Ambient Air Based, Portable, and Automated CO 2 Removal Controller for Artificial Lungs. ASAIO J 2023; 69:e301-e307. [PMID: 37146595 PMCID: PMC10580296 DOI: 10.1097/mat.0000000000001968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/07/2023] Open
Abstract
Portable artificial lung (AL) systems are under development, but there are few technologies available that adjust the carbon dioxide (CO 2 ) removal in response to changes in patient metabolic needs. Our work describes the second generation of a CO 2 -based portable servoregulation system that automatically adjusts CO 2 removal in ALs. Four adult sheep (68 ± 14.3 kg) were used to test the servoregulator. The servoregulator controlled air sweep flow through the lung to meet a target exhaust gas CO 2 (tEGCO 2 ) level in normocapnic and hypercapnic (arterial partial pressure of CO 2 [PaCO 2 ] >60 mm Hg) conditions at varying flow rates (0.5-1.5 L/min) and at tEGCO 2 levels of 10, 20, and 40 mm Hg. In hypercapnic sheep, average post-AL blood partial pressure of CO 2 (pCO 2 ) values were 22.4 ± 3.6 mm Hg for tEGCO 2 of 10 mm Hg, 28.0 ± 4.1 mm Hg for tEGCO 2 of 20 mm Hg and 40.6 ± 4.8 mm Hg for tEGCO 2 of 40 mm Hg. The controller successfully and automatically adjusted the sweep gas flow to rapidly (<10 minutes) meet the tEGCO 2 level when challenged with changes in inlet blood flow or target EGCO 2 levels for all animals. These in vivo data demonstrate an important step toward portable ALs that can automatically modulate CO 2 removal and allow for substantial changes in patient activity or disease status in ambulatory applications.
Collapse
Affiliation(s)
- Brianna L. Spencer
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Navid Shaikh
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Leah Gudex
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Tyler Dann
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Mark Langley
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Hannah Matich
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Robert H. Bartlett
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
| | - Alvaro Rojas
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
- Department of Surgery, Section of Transplantation, University of Michigan, Ann Arbor, MI 48109, USA
| | - Joseph A. Potkay
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| |
Collapse
|
2
|
Shaikh N, Zhang A, Jenter J, Nikpreljevic B, Toomasian J, Lynch W, Rojas-Peña A, Bartlett RH, Potkay JA. A Portable Servoregulation Controller to Automate CO 2 Removal in Artificial Lungs. Bioengineering (Basel) 2022; 9:bioengineering9100593. [PMID: 36290561 PMCID: PMC9598878 DOI: 10.3390/bioengineering9100593] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2022] [Revised: 10/16/2022] [Accepted: 10/17/2022] [Indexed: 11/16/2022] Open
Abstract
Artificial lung (AL) systems provide respiratory support to patients with severe lung disease, but none can adapt to the changing respiratory needs of the patients. Precisely, none can automatically adjust carbon dioxide (CO2) removal from the blood in response to changes in patient activity or disease status. Because of this, all current systems limit patient comfort, activity level, and rehabilitation. A portable servoregulation controller that automatically modulates CO2 removal in ALs to meet the real-time metabolic demands of the patient is described. The controller is based on a proportional-integral-derivative (PID) based closed-loop feedback control system that modulates sweep gas (air) flow through the AL to maintain a target exhaust gas CO2 partial pressure (target EGCO2 or tEGCO2). The presented work advances previous research by (1) using gas-side sensing that avoids complications and clotting associated with blood-based sensors, (2) incorporating all components into a portable, battery-powered package, and (3) integrating smart moisture removal from the AL to enable long term operation. The performance of the controller was tested in vitro for ∼12 h with anti-coagulated bovine blood and 5 days with distilled water. In tests with blood, the sweep gas flow was automatically adjusted by the controller rapidly (<2 min) meeting the specified tEGCO2 level when confronted with changes in inlet blood partial pressure of CO2 (pCO2) levels at various AL blood flows. Overall, the CO2 removal from the AL showed a strong correlation with blood flow rate and blood pCO2 levels. The controller successfully operated continuously for 5 days when tested with water. This study demonstrates an important step toward ambulatory AL systems that automatically modulate CO2 removal as required by lung disease patients, thereby allowing for physiotherapy, comfort, and activity.
Collapse
Affiliation(s)
- Navid Shaikh
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
- Correspondence:
| | - Andrew Zhang
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| | - Jesse Jenter
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| | - Brandon Nikpreljevic
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| | - John Toomasian
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - William Lynch
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Alvaro Rojas-Peña
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Robert H. Bartlett
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
| | - Joseph A. Potkay
- Extracorporeal Life Support Laboratory, Department of Surgery, University of Michigan, Ann Arbor, MI 48109, USA
- VA Ann Arbor Healthcare System, Ann Arbor, MI 48105, USA
| |
Collapse
|
3
|
Astor TL, Borenstein JT. The microfluidic artificial lung: Mimicking nature's blood path design to solve the biocompatibility paradox. Artif Organs 2022; 46:1227-1239. [PMID: 35514275 DOI: 10.1111/aor.14266] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2022] [Revised: 04/03/2022] [Accepted: 04/04/2022] [Indexed: 11/28/2022]
Abstract
The increasing prevalence of chronic lung disease worldwide, combined with the emergence of multiple pandemics arising from respiratory viruses over the past century, highlights the need for safer and efficacious means for providing artificial lung support. Mechanical ventilation is currently used for the vast majority of patients suffering from acute and chronic lung failure, but risks further injury or infection to the patient's already compromised lung function. Extracorporeal membrane oxygenation (ECMO) has emerged as a means of providing direct gas exchange with the blood, but limited access to the technology and the complexity of the blood circuit have prevented the broader expansion of its use. A promising avenue toward simplifying and minimizing complications arising from the blood circuit, microfluidics-based artificial organ support, has emerged over the past decade as an opportunity to overcome many of the fundamental limitations of the current standard for ECMO cartridges, hollow fiber membrane oxygenators. The power of microfluidics technology for this application stems from its ability to recapitulate key aspects of physiological microcirculation, including the small dimensions of blood vessel structures and gas transfer membranes. An even greater advantage of microfluidics, the ability to configure blood flow patterns that mimic the smooth, branching nature of vascular networks, holds the potential to reduce the incidence of clotting and bleeding and to minimize reliance on anticoagulants. Here, we summarize recent progress and address future directions and goals for this potentially transformative approach to artificial lung support.
Collapse
Affiliation(s)
- Todd L Astor
- Biomembretics, Inc., Boston, Massachusetts, USA.,Department of Medicine, Massachusetts General Hospital, Boston, Massachusetts, USA
| | | |