Gruneberg D, Dietrich M, Studier-Fischer A, Petersen C, von der Forst M, Özdemir B, Schöchl H, Nickel F, Weigand MA, Schmitt FCF. Comparison of two viscoelastic testing devices in a porcine model of surgery, hemorrhage and resuscitation. Front Bioeng Biotechnol 2024; 12:1417847. [PMID: 39193228 PMCID: PMC11347288 DOI: 10.3389/fbioe.2024.1417847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Accepted: 07/26/2024] [Indexed: 08/29/2024] Open
Abstract
Introduction Viscoelastic hemostatic assays (VHA) are integral in contemporary hemostatic resuscitation, offering insights into clot formation, firmness, and lysis for rapid diagnosis and targeted therapy. Large animal models, particularly swine, provide anatomical and physiological analogies for coagulation research. Despite the growing use of VHAs, the ClotPro® device's applicability in porcine models remains unexplored. This study investigates ClotPro® in a porcine model of abdominal surgery, severe hemorrhage, and resuscitation, comparing it with the established ROTEM® delta system. Methods Twenty-seven healthy pigs underwent abdominal surgery, hemorrhage and resuscitation. ClotPro® and ROTEM® were used to assess viscoelastic hemostatic properties at baseline, after surgery, 60 min after shock induction, 60 and 120 min after resuscitation. Results Clotting times in extrinsically and intrinsically stimulated assays exhibited fair to moderate correlation. Clot firmness in extrinsically stimulated tests could be used interchangeably while fibrin polymerization assays revealed significant differences between the devices. Fibrin polymerization assays in ClotPro® consistently yielded higher values than ROTEM®. Furthermore, the study evaluated the ClotPro® TPA-test's applicability in porcine blood, revealing failure of lysis induction in porcine blood samples. Conclusion This research contributes valuable insights into the use of ClotPro® in porcine models of hemorrhage and coagulopathy, highlighting both its applicability and limitations in comparison to ROTEM® delta. The observed differences, especially in fibrin polymerization assays, emphasize the importance of understanding device-specific characteristics when interpreting results. Due to its inapplicability, TPA-test should not be used in porcine blood to evaluate fibrinolytic potential. The study provides a foundation for future investigations into the use of different viscoelastic hemostatic assays in porcine animal models.
Collapse
Affiliation(s)
- Daniel Gruneberg
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| | - Maximilian Dietrich
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| | - Alexander Studier-Fischer
- Department of General, Visceral, and Trasplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Clara Petersen
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| | - Maik von der Forst
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| | - Berkin Özdemir
- Department of General, Visceral, and Trasplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Herbert Schöchl
- Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with AUVA, Vienna, Austria
| | - Felix Nickel
- Department of General, Visceral, and Trasplantation Surgery, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus A. Weigand
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| | - Felix C. F. Schmitt
- Department of Anesthesiology, Medical Faculty Heidelberg, Heidelberg University, Heidelberg, Germany
| |
Collapse
|
2
|
Gruneberg D, Braun P, Schöchl H, Nachtigall-Schmitt T, von der Forst M, Tourelle K, Dietrich M, Wallwiener M, Wallwiener S, Weigand MA, Fluhr H, Spratte J, Hofer S, Schmitt FCF. Fibrinolytic potential as a risk factor for postpartum hemorrhage. Front Med (Lausanne) 2023; 10:1208103. [PMID: 37746089 PMCID: PMC10516290 DOI: 10.3389/fmed.2023.1208103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Accepted: 07/27/2023] [Indexed: 09/26/2023] Open
Abstract
Background Postpartum hemorrhage (PPH) is still the leading cause of maternal morbidity and mortality worldwide. While impaired fibrin polymerization plays a crucial role in the development and progress of PPH, recent approaches using viscoelastic measurements have failed to sensitively detect early changes in fibrinolysis in PPH. This study aimed to evaluate whether women experiencing PPH show alterations in POC-VET fibrinolytic potential during childbirth and whether fibrinolytic potential offers benefits in the prediction and treatment of PPH. Methods Blood samples were collected at three different timepoints: T0 = hospital admission (19 h ± 18 h prepartum), T1 = 30-60 min after placental separation, and T2 = first day postpartum (19 h ± 6 h postpartum). In addition to standard laboratory tests, whole-blood impedance aggregometry (Multiplate) and viscoelastic testing (VET) were performed using the ClotPro system, which included the TPA-test lysis time, to assess the POC-VET fibrinolytic potential, and selected coagulation factors were measured. The results were correlated with blood loss and clinical outcome markers. Severe PPH was defined as a hemoglobin drop > 4g/dl and/or the occurrence of shock or the need for red blood cell transfusion. Results Blood samples of 217 parturient women were analyzed between June 2020 and December 2020 at Heidelberg University Women's Hospital, and 206 measurements were eligible for the final analysis. Women experiencing severe PPH showed increased fibrinolytic potential already at the time of hospital admission. When compared to non-PPH, the difference persisted 30-60 min after placental separation. A higher fibrinolytic potential was accompanied by a greater drop in fibrinogen and higher d-dimer values after placental separation. While 70% of women experiencing severe PPH showed fibrinolytic potential, 54% of those without PPH showed increased fibrinolytic potential as well. Conclusion We were able to show that antepartal and peripartal fibrinolytic potential was elevated in women experiencing severe PPH. However, several women showed high fibrinolytic potential but lacked clinical signs of PPH. The findings indicate that high fibrinolytic potential is a risk factor for the development of coagulopathy, but further conditions are required to cause PPH.
Collapse
Affiliation(s)
- Daniel Gruneberg
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Paula Braun
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Herbert Schöchl
- Ludwig Boltzmann Institute for Traumatology, The Research Center in Cooperation with Allgemeine Unfallversicherungsanstalt, Vienna, Austria
| | | | - Maik von der Forst
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Kevin Tourelle
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Maximilian Dietrich
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Markus Wallwiener
- Department of Obstetrics and Gynecology, University of Heidelberg, Heidelberg, Germany
| | - Stephanie Wallwiener
- Department of Obstetrics and Gynecology, University of Heidelberg, Heidelberg, Germany
| | - Markus A. Weigand
- Department of Anesthesiology, Heidelberg University Hospital, Heidelberg, Germany
| | - Herbert Fluhr
- Division of Obstetrics, Department of Obstetrics and Gynecology, Medical University of Graz, Graz, Austria
| | - Julia Spratte
- Department of Obstetrics and Gynecology, University of Heidelberg, Heidelberg, Germany
| | - Stefan Hofer
- Department of Anesthesiology, Kaiserslautern Westpfalz Hospital, Kaiserslautern, Germany
| | | |
Collapse
|
3
|
Coupland LA, Rabbolini DJ, Schoenecker JG, Crispin PJ, Miller JJ, Ghent T, Medcalf RL, Aneman AE. Point-of-care diagnosis and monitoring of fibrinolysis resistance in the critically ill: results from a feasibility study. Crit Care 2023; 27:55. [PMID: 36765421 PMCID: PMC9912243 DOI: 10.1186/s13054-023-04329-5] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Accepted: 01/22/2023] [Indexed: 02/12/2023] Open
Abstract
BACKGROUND Fibrinolysisis is essential for vascular blood flow maintenance and is triggered by endothelial and platelet release of tissue plasminogen activator (t-PA). In certain critical conditions, e.g. sepsis, acute respiratory failure (ARF) and trauma, the fibrinolytic response is reduced and may lead to widespread thrombosis and multi-organ failure. The mechanisms underpinning fibrinolysis resistance include reduced t-PA expression and/or release, reduced t-PA and/or plasmin effect due to elevated inhibitor levels, increased consumption and/or clearance. This study in critically ill patients with fibrinolysis resistance aimed to evaluate the ability of t-PA and plasminogen supplementation to restore fibrinolysis with assessment using point-of-care ClotPro viscoelastic testing (VET). METHODS In prospective, observational studies, whole-blood ClotPro VET evaluation was carried out in 105 critically ill patients. In 32 of 58 patients identified as fibrinolysis-resistant (clot lysis time > 300 s on the TPA-test: tissue factor activated coagulation with t-PA accelerated fibrinolysis), consecutive experimental whole-blood VET was carried out with repeat TPA-tests spiked with additional t-PA and/or plasminogen and the effect on lysis time determined. In an interventional study in a patient with ARF and fibrinolysis resistance, the impact of a 24 h intravenous low-dose alteplase infusion on coagulation and fibrinolysis was prospectively monitored using standard ClotPro VET. RESULTS Distinct response groups emerged in the ex vivo experimental VET, with increased fibrinolysis observed following supplementation with (i) t-PA only or (ii) plasminogen and t-PA. A baseline TPA-test lysis time of > 1000 s was associated with the latter group. In the interventional study, a gradual reduction (25%) in serial TPA-test lysis times was observed during the 24 h low-dose alteplase infusion. CONCLUSIONS ClotPro viscoelastic testing, the associated TPA-test and the novel experimental assays may be utilised to (i) investigate the potential mechanisms of fibrinolysis resistance, (ii) guide corrective treatment and (iii) monitor in real-time the treatment effect. Such a precision medicine and personalised treatment approach to the management of fibrinolysis resistance has the potential to increase treatment benefit, while minimising adverse events in critically ill patients. TRIAL REGISTRATION VETtiPAT-ARF, a clinical trial evaluating ClotPro-guided t-PA (alteplase) administration in fibrinolysis-resistant patients with ARF, is ongoing (ClinicalTrials.gov NCT05540834 ; retrospectively registered September 15th 2022).
Collapse
Affiliation(s)
- Lucy A. Coupland
- grid.415994.40000 0004 0527 9653Intensive Care Unit, Liverpool Hospital, Liverpool, Australia ,grid.429098.eIngham Institute for Applied Medical Research, 1 Campbell St, Liverpool, NSW 2170 Australia
| | - David J. Rabbolini
- grid.1013.30000 0004 1936 834XKolling Institute of Medical Research, Faculty of Medicine and Health, University of Sydney, Sydney, Australia ,grid.410556.30000 0001 0440 1440Oxford Haemophilia and Thrombosis Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, UK
| | - Jonathan G. Schoenecker
- grid.412807.80000 0004 1936 9916Department of Orthopaedics and Pharmacology, Vanderbilt University Medical Center, Nashville, TN USA
| | - Philip J. Crispin
- grid.413314.00000 0000 9984 5644Haematology Department, The Canberra Hospital, Canberra, Australia ,grid.1001.00000 0001 2180 7477The Australian National University Medical School, Canberra, Australia
| | - Jennene J. Miller
- grid.415994.40000 0004 0527 9653Intensive Care Unit, Liverpool Hospital, Liverpool, Australia
| | - Tony Ghent
- grid.413154.60000 0004 0625 9072Intensive Care Unit, Gold Coast University Hospital, South Port, Australia
| | - Robert L. Medcalf
- grid.1002.30000 0004 1936 7857Australian Centre for Blood Diseases, Monash University, Melbourne, Australia
| | - Anders E. Aneman
- grid.415994.40000 0004 0527 9653Intensive Care Unit, Liverpool Hospital, Liverpool, Australia ,grid.429098.eIngham Institute for Applied Medical Research, 1 Campbell St, Liverpool, NSW 2170 Australia
| |
Collapse
|
4
|
Bunch CM, Berquist M, Ansari A, McCoy ML, Langford JH, Brenner TJ, Aboukhaled M, Thomas SJ, Peck E, Patel S, Cancel E, Al-Fadhl MD, Zackariya N, Thomas AV, Aversa JG, Greene RB, Seder CW, Speybroeck J, Miller JB, Kwaan HC, Walsh MM. The Choice between Plasma-Based Common Coagulation Tests and Cell-Based Viscoelastic Tests in Monitoring Hemostatic Competence: Not an either-or Proposition. Semin Thromb Hemost 2022; 48:769-784. [PMID: 36174601 DOI: 10.1055/s-0042-1756302] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
There has been a significant interest in the last decade in the use of viscoelastic tests (VETs) to determine the hemostatic competence of bleeding patients. Previously, common coagulation tests (CCTs) such as the prothrombin time (PT) and partial thromboplastin time (PTT) were used to assist in the guidance of blood component and hemostatic adjunctive therapy for these patients. However, the experience of decades of VET use in liver failure with transplantation, cardiac surgery, and trauma has now spread to obstetrical hemorrhage and congenital and acquired coagulopathies. Since CCTs measure only 5 to 10% of the lifespan of a clot, these assays have been found to be of limited use for acute surgical and medical conditions, whereby rapid results are required. However, there are medical indications for the PT/PTT that cannot be supplanted by VETs. Therefore, the choice of whether to use a CCT or a VET to guide blood component therapy or hemostatic adjunctive therapy may often require consideration of both methodologies. In this review, we provide examples of the relative indications for CCTs and VETs in monitoring hemostatic competence of bleeding patients.
Collapse
Affiliation(s)
- Connor M Bunch
- Department of Emergency Medicine, Henry Ford Hospital, Detroit, Michigan
| | - Margaret Berquist
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Aida Ansari
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Max L McCoy
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Jack H Langford
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Toby J Brenner
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Michael Aboukhaled
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Samuel J Thomas
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Ethan Peck
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Shivani Patel
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Emily Cancel
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana
| | - Mahmoud D Al-Fadhl
- Indiana University School of Medicine, Notre Dame Campus, South Bend, Indiana
| | - Nuha Zackariya
- Indiana University School of Medicine, Notre Dame Campus, South Bend, Indiana
| | - Anthony V Thomas
- Indiana University School of Medicine, Notre Dame Campus, South Bend, Indiana
| | - John G Aversa
- Department of Surgery, Indiana University School of Medicine, Indianapolis, Indiana
| | - Ryan B Greene
- Department of Interventional Radiology, St. Joseph Regional Medical Center, Mishawaka, Indiana
| | - Christopher W Seder
- Department of Cardiovascular and Thoracic Surgery, Rush University Medical Center, Chicago, Illinois
| | - Jacob Speybroeck
- Department of Orthopedic Surgery, Case Western Medical Center, Cleveland, Ohio
| | - Joseph B Miller
- Department of Emergency Medicine, Henry Ford Hospital, Detroit, Michigan
| | - Hau C Kwaan
- Division of Hematology and Oncology, Department of Medicine, Northwestern University Feinberg School of Medicine, Chicago, Illinois
| | - Mark M Walsh
- Department of Emergency Medicine, Saint Joseph Regional Medical Center, Mishawaka, Indiana.,Indiana University School of Medicine, Notre Dame Campus, South Bend, Indiana
| |
Collapse
|
5
|
Infanger L, Dibiasi C, Schaden E, Ulbing S, Wiegele M, Lacom C, Gratz J. Comparison of the New Viscoelastic Coagulation Analyzer ClotPro® With ROTEM® Delta and Conventional Coagulation Tests in Critically Ill Patients With COVID-19. Front Med (Lausanne) 2021; 8:777145. [PMID: 34869496 PMCID: PMC8635118 DOI: 10.3389/fmed.2021.777145] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/14/2021] [Accepted: 10/27/2021] [Indexed: 12/12/2022] Open
Abstract
Background: Viscoelastic coagulation testing has been suggested to help manage coagulopathy in critically ill patients with COVID-19. However, results from different viscoelastic devices are not readily comparable. ClotPro® is a novel thromboelastometry analyzer offering a wider range of commercially available assays. Methods: We compared the results from ClotPro with results from the well-established ROTEM® Delta device and conventional coagulation tests in critically ill patients with COVID-19. Results: Viscoelastic parameters indicated the presence of a potentially hypercoagulable state in the majority of patients. In up to 95 paired measurements, we found strong correlations between several parameters routinely used in clinical practice: (i) EX test vs. EXTEM CT, A5, A10, MCF, (ii) IN test vs. INTEM A5, A10, MCF, and (iii) FIB test vs. FIBTEM A5, A10, MCF (all R > 0.7 and p < 0.001). In contrast, IN test CT vs. INTEM CT showed only a moderate correlation (R = 0.53 and p < 0.001). Clot strength parameters of both devices exhibited strong correlations with platelet counts and fibrinogen levels (all R > 0.7 and p < 0.001). Divergent correlations of intrinsically activated assays with aPTT and anti-factor Xa activity were visible. Regarding absolute differences of test results, considerable delta occurred in CT, CFT, and clot strength parameters (all p < 0.001) between both devices. Conclusions: Several parameters obtained by ClotPro show strong correlations with ROTEM Delta. Due to weak correlations of intrinsically activated clotting times and considerable absolute differences in a number of parameters, our findings underline the need for device-specific algorithms in this patient cohort.
Collapse
Affiliation(s)
- Lukas Infanger
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Christoph Dibiasi
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Eva Schaden
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Stefan Ulbing
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Marion Wiegele
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Conrad Lacom
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| | - Johannes Gratz
- Department of Anaesthesia, Intensive Care Medicine and Pain Medicine, Medical University of Vienna, Vienna, Austria
| |
Collapse
|