1
|
Dai J, Lv Q, Li Y, Wang Z, Guo J. Frame composite imaging method based on time-sharing latency excitation for ultrasound shear wave elastography. ULTRASONICS 2024; 144:107396. [PMID: 39173277 DOI: 10.1016/j.ultras.2024.107396] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Revised: 06/28/2024] [Accepted: 07/02/2024] [Indexed: 08/24/2024]
Abstract
Ultrasound shear wave elastography is an imaging modality that noninvasively assesses mechanical properties of tissues. The results of elastic imaging are obtained by accurately estimating the propagation velocity of shear wave fronts. However, the acquisition rate of the shear wave acquisition device is limited by the hardware of the system. Therefore, increasing the collection rate of shear waves can directly improve the quality of shear wave velocity images. In addition, the problem of velocity reconstruction with relatively small elastic inclusions has always been a challenge in elastic imaging and a very important and urgent issue in early disease diagnosis. For the problem of elastography detection of the shape and boundary of inclusions in tissues, Time-sharing latency excitation frame composite imaging (TS-FCI) method is proposed for tissue elasticity measurement. The method fuses the shear wave motion data generated by time sharing and latency excitation to obtain a set of composite shear wave motion data. Based on the shear wave motion data, the local shear wave velocity image is reconstructed in the frequency domain to obtain the elastic information of the tissue. The experimental results show that the TS-FCI method has a velocity estimation error of 11 % and a contrast to noise ratio (CNR) of 3.81 when estimating inclusions with smaller dimensions (2.53 mm). Furthermore, when dealing with inclusions with small elastic changes (10 kPa), the velocity estimation error is 3 % and the CNR is 3.21. Compared to conventional time-domain and frequency-domain analysis methods, the proposed method has advantages. Results and analysis have shown that this method has potential promotional value in the quantitative evaluation of organizational elasticity.
Collapse
Affiliation(s)
- Jiayue Dai
- Shaanxi Normal University, the Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Xi'an 710062, China
| | - Qian Lv
- Shaanxi Normal University, the Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Xi'an 710062, China
| | - Yu Li
- Shaanxi Normal University, the Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Xi'an 710062, China
| | - Zhi Wang
- Shaanxi Normal University, the Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Xi'an 710062, China
| | - Jianzhong Guo
- Shaanxi Normal University, the Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Xi'an 710062, China.
| |
Collapse
|
2
|
Shu J, Deng H, Zhang Y, Wu F, He J. Cancer cell response to extrinsic and intrinsic mechanical cue: opportunities for tumor apoptosis strategies. Regen Biomater 2024; 11:rbae016. [PMID: 38476678 PMCID: PMC10932484 DOI: 10.1093/rb/rbae016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2023] [Revised: 01/31/2024] [Accepted: 02/07/2024] [Indexed: 03/14/2024] Open
Abstract
Increasing studies have revealed the importance of mechanical cues in tumor progression, invasiveness and drug resistance. During malignant transformation, changes manifest in either the mechanical properties of the tissue or the cellular ability to sense and respond to mechanical signals. The major focus of the review is the subtle correlation between mechanical cues and apoptosis in tumor cells from a mechanobiology perspective. To begin, we focus on the intracellular force, examining the mechanical properties of the cell interior, and outlining the role that the cytoskeleton and intracellular organelle-mediated intracellular forces play in tumor cell apoptosis. This article also elucidates the mechanisms by which extracellular forces guide tumor cell mechanosensing, ultimately triggering the activation of the mechanotransduction pathway and impacting tumor cell apoptosis. Finally, a comprehensive examination of the present status of the design and development of anti-cancer materials targeting mechanotransduction is presented, emphasizing the underlying design principles. Furthermore, the article underscores the need to address several unresolved inquiries to enhance our comprehension of cancer therapeutics that target mechanotransduction.
Collapse
Affiliation(s)
- Jun Shu
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, PR China
| | - Huan Deng
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, PR China
| | - Yu Zhang
- College of Food and Biological Engineering, Chengdu University, Chengdu 610106, PR China
| | - Fang Wu
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, PR China
| | - Jing He
- National Engineering Research Center for Biomaterials, College of Biomedical Engineering, Sichuan University, Chengdu 610064, PR China
| |
Collapse
|
3
|
Hu J, Lv Z, Dong Y, Liu W. Review of shear wave elastography in placental function evaluations. J Matern Fetal Neonatal Med 2023; 36:2203792. [PMID: 37121902 DOI: 10.1080/14767058.2023.2203792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/02/2023]
Abstract
Background: Ultrasound is key to evaluating placental function. However, traditional ultrasound examinations cannot evaluate the changes in the biomechanical properties of the placenta in vivo. As a non-invasive technique, shear wave elastography (SWE) can be used analyze the physiological and biomechanical properties of the placenta. Moreover, it can evaluate the pathological changes in early placental insufficiency in a more direct and sensitive manner.Objective: This study aimed to systematically introduce SWE in placental function evaluations.Materials and methods: The terms 'placenta', 'ultrasound', and 'elastography' were searched on Pubmed, Embase, and CNKI databases (Apr 2023); this review was limited to results including placental sonoelastography.Results: Twenty-six studies satisfied the inclusion criteria and were included in this review. Herein, we introduce the basic principle of SWE, analyze the factors affecting placental measurements, and summarize the prospects of clinical applications of SWE in the field of obstetrical diseases.Conclusion: The SWE technology demonstrates excellent clinical application value and research prospects in obstetrics, particularly in placental function evaluation, owing to its objective and repeatable quantitative operation.
Collapse
Affiliation(s)
- Jingyuan Hu
- Department of Medical Ultrasound, Shandong Medicine and Health Key Laboratory of Abdominal Medical Imaging, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Zimeng Lv
- Department of Medical Ultrasound, Shandong Medicine and Health Key Laboratory of Abdominal Medical Imaging, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Yue Dong
- Department of Medical Ultrasound, Shandong Medicine and Health Key Laboratory of Abdominal Medical Imaging, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| | - Wei Liu
- Department of Medical Ultrasound, Shandong Medicine and Health Key Laboratory of Abdominal Medical Imaging, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China
| |
Collapse
|
4
|
Hu X, Sun C, Ren X, Ge S, Xie C, Li X, Zhu Y, Ding H. Contrast-enhanced Ultrasound Combined With Elastography for the Evaluation of Muscle-invasive Bladder Cancer in Rats. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2023; 42:1999-2011. [PMID: 36896871 DOI: 10.1002/jum.16216] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Revised: 02/17/2023] [Accepted: 02/21/2023] [Indexed: 06/18/2023]
Abstract
OBJECTIVES By comparing with the control group, we evaluated the usefulness of contrast-enhanced ultrasound (CEUS) combined with elastography for the assessment of muscle invasion by bladder cancer (MIBC) in a Sprague-Dawley (SD) rat model. METHODS In the experimental group, 40 SD rats developed in situ bladder cancer (BLCA) in response to N-methyl-N-nitrosourea treatment, whereas 40 SD rats were included in the control group for comparison. We compared PI, Emean , microvessel density (MVD), and collagen fiber content (CFC) between the two groups. In the experimental group, Bland-Altman test was used to assess the relationships between various parameters. The largest Youden value was used as the cut-off point, and binomial logistic regression analysis was performed to analyze the PI and Emean . Receiver operating characteristic (ROC) curve analysis was performed to determine the diagnostic power of parameters, individually and in combination. RESULTS The PI, Emean , MVD, and CFC were significantly lower in the control group than in the experimental group (P < .05). The PI, Emean , MVD, and CFC were significantly higher for MIBC than for non-muscle-invasive bladder cancer (P < .05). There were significant correlations between PI and MVD, and between Emean and CFC. The diagnostic efficiency analysis showed PI had the highest sensitivity, CFC had the highest specificity, and PI + Emean had the highest diagnostic efficacy. CONCLUSION CEUS and elastography can distinguish lesions from normal tissue. PI, MVD, Emean , and CFC were useful for the detection of BLCA myometrial invasion. The comprehensive utilization of PI and Emean improved diagnostic accuracy and have clinical application.
Collapse
Affiliation(s)
- Xing Hu
- Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, China
| | - Chuanyu Sun
- Department of Urology, Huashan Hospital, Fudan University, Shanghai, China
| | - Xinping Ren
- Department of Ultrasound, Ruijin Hospital, Shanghai Jiaotong University, Shanghai, China
| | - Shengyang Ge
- Department of Urology, Huashan Hospital, Fudan University, Shanghai, China
| | - Chunmei Xie
- Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, China
| | - Xiangyu Li
- Department of Laboratory Medicine, Huashan Hospital, Fudan University, Shanghai, China
| | - Yingfeng Zhu
- Department of Pathology, Huashan Hospital, Fudan University, Shanghai, China
| | - Hong Ding
- Department of Ultrasound, Huashan Hospital, Fudan University, Shanghai, China
| |
Collapse
|
5
|
Quantitative Assessment of Breast-Tumor Stiffness Using Shear-Wave Elastography Histograms. Diagnostics (Basel) 2022; 12:diagnostics12123140. [PMID: 36553148 PMCID: PMC9777730 DOI: 10.3390/diagnostics12123140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/08/2022] [Accepted: 12/11/2022] [Indexed: 12/15/2022] Open
Abstract
Purpose: Shear-wave elastography (SWE) measures tissue elasticity using ultrasound waves. This study proposes a histogram-based SWE analysis to improve breast malignancy detection. Methods: N = 22/32 (patients/tumors) benign and n = 51/64 malignant breast tumors with histological ground truth. Colored SWE heatmaps were adjusted to a 0−180 kPa scale. Normalized, 250-binned RGB histograms were used as image descriptors based on skewness and area under curve (AUC). The histogram method was compared to conventional SWE metrics, such as (1) the qualitative 5-point scale classification and (2) average stiffness (SWEavg)/maximal tumor stiffness (SWEmax) within the tumor B-mode boundaries. Results: The SWEavg and SWEmax did not discriminate malignant lesions in this database, p > 0.05, rank sum test. RGB histograms, however, differed between malignant and benign tumors, p < 0.001, Kolmogorov−Smirnoff test. The AUC analysis of histograms revealed the reduction of soft-tissue components as a significant SWE biomarker (p = 0.03, rank sum). The diagnostic accuracy of the suggested method is still low (Se = 0.30 for Se = 0.90) and a subject for improvement in future studies. Conclusions: Histogram-based SWE quantitation improved the diagnostic accuracy for malignancy compared to conventional average SWE metrics. The sensitivity is a subject for improvement in future studies.
Collapse
|
6
|
Yang X, Ding Y, Mei J, Xiong W, Wang J, Huang Z, Li R. Second-Trimester Cervical Shear Wave Elastography Combined With Cervical Length for the Prediction of Spontaneous Preterm Birth. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:820-829. [PMID: 35272890 DOI: 10.1016/j.ultrasmedbio.2022.01.003] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Revised: 12/06/2021] [Accepted: 01/06/2022] [Indexed: 06/14/2023]
Abstract
The goal of this study was to explore the value of shear wave elastography (SWE) combined with cervical length (CL) in the prediction of spontaneous preterm birth (sPTB) between 18 and 24 weeks of gestation. In this study, SWE was used to evaluate four regions of the cervix: the external and anterior lip (region A1), the external and posterior lip (region A2), the internal and anterior lip (region A3) and the internal and posterior lip (region A4). The cervical Young's modulus (YM) was compared between women who spontaneously delivered prematurely (<37 wk) and those who delivered full term. Finally, the predictive power of SWE was evaluated using receiver operating characteristic analysis. Overall, 773 patients were included in this study, of whom 60 (7.8%) had a sPTB. In the univariate analysis, prior sPTB, history of spontaneous abortion, history of cervical surgery, CL and YM at the anterior portion of both the internal and external os and the posterior portion of the internal os were associated with sPTB (p < 0.05). Multiple regression analyses were performed to develop the prediction probability for sPTB. YM and CL were independent predictors of sPTB in asymptomatic women, and the combination of YM and CL improved the ability to predict sPTB (area under the receiver operating characteristic curve = 0.98, 95% confidence interval: 0.97-0.99, p < 0.001). The interventions had relatively little impact on the outcome indicators measured. Cervical YM added to the CL may improve the predictive performance of second-trimester transvaginal ultrasound for sPTB.
Collapse
Affiliation(s)
- Xiaofeng Yang
- First Affiliate Hospital of Jinan University, Guangzhou, China
| | - Yuzhen Ding
- First Affiliate Hospital of Jinan University, Guangzhou, China
| | - Jie Mei
- Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China
| | - Wen Xiong
- Sichuan Academy of Medical Sciences and Sichuan Provincial People's Hospital, Chengdu, China
| | - Jingyun Wang
- First Affiliate Hospital of Jinan University, Guangzhou, China
| | - Zhengrui Huang
- First Affiliate Hospital of Jinan University, Guangzhou, China
| | - Ruiman Li
- First Affiliate Hospital of Jinan University, Guangzhou, China.
| |
Collapse
|
7
|
Săsăran V, Turdean S, Gliga M, Ilyes L, Grama O, Muntean M, Pușcașiu L. Value of Strain-Ratio Elastography in the Diagnosis and Differentiation of Uterine Fibroids and Adenomyosis. J Pers Med 2021; 11:jpm11080824. [PMID: 34442468 PMCID: PMC8399978 DOI: 10.3390/jpm11080824] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 08/19/2021] [Accepted: 08/21/2021] [Indexed: 12/26/2022] Open
Abstract
Benign uterine disorders, including uterine fibroids (UF) and adenomyosis (AM), can impact the life quality and fertility of women of reproductive age. Transvaginal ultrasound (TVUS) has long been used for their early identification, but its combined use with elastography seems to improve diagnostic accuracy of UF and AM. Thus, a prospective pilot study was conducted on 79 patients who underwent hysterectomy (25 microscopically diagnosed with AM and 53 with UF), with the aim of assessing the ability of TVUS combined with strain ratio elastography (SE) to accurately diagnose and distinguish UF and AM. Significantly higher mean and maximal strain ratio (SR) values were identified for patients with histologically confirmed AM as opposed to those with UF (p < 0.001). Diagnostic sensitivity and specificity, calculated in comparison with histology results, were higher for UF than AM. Receiver operating characteristic (ROC) analysis was applied between the two study groups, revealing cutoff values of 7.71 for mean SR and 8.91 for maximal SR, respectively, with good sensitivity and specificity parameters (100% and 96.23%; 96% and 96.23%). Our results support the use of TVUS in combination with SE for the positive and differential diagnosis of UF and AM, through identification of their particular tissue stiffness features.
Collapse
Affiliation(s)
- Vladut Săsăran
- Department of Obstetrics and Gynecology 2, Faculty of Medicine in English, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania;
| | - Sabin Turdean
- Department of Morphopathology, Faculty of Medicine, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania
- Correspondence:
| | - Marius Gliga
- Department of Obstetrics and Gynecology 2, Faculty of Medicine, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania; (M.G.); (L.I.); (O.G.)
| | - Levente Ilyes
- Department of Obstetrics and Gynecology 2, Faculty of Medicine, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania; (M.G.); (L.I.); (O.G.)
| | - Ovidiu Grama
- Department of Obstetrics and Gynecology 2, Faculty of Medicine, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania; (M.G.); (L.I.); (O.G.)
| | - Mihai Muntean
- Department of Obstetrics and Gynecology, Clinical County Hospital Mures, Samuel Koteles Street No. 29, 540057 Târgu Mureș, Romania;
| | - Lucian Pușcașiu
- Department of Obstetrics and Gynecology 1, Faculty of Medicine in English, “George Emil Palade” University of Medicine, Pharmacy, Sciences and Technology of Târgu Mureș, Gheorghe Marinescu Street No. 38, 540136 Târgu Mureș, Romania;
| |
Collapse
|