1
|
Barone G, Pittiruti M, Prontera G, Ancora G, D'Andrea V. A novel neonatal protocol for Safe Insertion of Umbilical Venous Catheters (SIUVeC): Minimizing complications in placement and management. J Vasc Access 2025; 26:681-686. [PMID: 38436297 DOI: 10.1177/11297298241236220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024] Open
Abstract
Insertion of umbilical venous catheters is a common procedure in neonatal intensive care. Though sometimes lifesaving, this maneuver is potentially associated with early and late complications, some of which may be severe and even life threatening (catheter malposition, hepatic lesions, venous thrombosis, pericardial effusion, etc.). The recent literature suggests several operative strategies that, if adopted systematically, may significantly reduce the incidence of both early and late catheter related complications. This paper describes a standardized protocol (Safe Insertion Umbilical Venous Catheter = SIUVeC) which incorporates such novel strategies, with the goal of minimizing the complications related to this procedure.
Collapse
MESH Headings
- Humans
- Umbilical Veins/diagnostic imaging
- Infant, Newborn
- Catheterization, Peripheral/adverse effects
- Catheterization, Peripheral/instrumentation
- Catheterization, Peripheral/standards
- Catheterization, Peripheral/methods
- Catheters, Indwelling
- Risk Factors
- Clinical Protocols
- Catheterization, Central Venous/adverse effects
- Catheterization, Central Venous/instrumentation
- Catheterization, Central Venous/methods
- Catheterization, Central Venous/standards
- Treatment Outcome
- Punctures
Collapse
Affiliation(s)
- Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL della Romagna, Rimini, Emilia Romagna, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Lazio, Italy
| | - Giorgia Prontera
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Lazio, Italy
| | - Gina Ancora
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL della Romagna, Rimini, Emilia Romagna, Italy
| | - Vito D'Andrea
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Lazio, Italy
| |
Collapse
|
2
|
Wren JT, Eslambolchi A, Clark K, Najaf T. Affordable Implementation of a Point-of-Care Ultrasound Program in a Large Tertiary Neonatal Intensive Care Unit to Assess Umbilical Venous Catheter Tips and Aid Central Placement. Am J Perinatol 2025; 42:334-341. [PMID: 38955218 DOI: 10.1055/a-2358-6632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
OBJECTIVE This study aimed to implement a point-of-care ultrasound (POCUS) program into a large neonatal intensive care unit (NICU) to enhance care by improving (1) umbilical venous catheter (UVC) tip identification and (2) central placement. STUDY DESIGN A POCUS program was established with core providers who received training from external and internal experts. A prospective study (n = 94) compared the accuracy of UVC identification between neonatology-performed ultrasound (NeoUS) and X-ray relative to a referent of radiology-interpreted ultrasound. Finally, an ultrasound-guided UVC insertion protocol was introduced to rescue noncentral traditionally placed catheters (n = 37). RESULTS Program implementation trained six providers for a total cost of approximately $10,500 USD. NeoUS was more accurate than X-ray at identifying UVC location (81.9 vs. 60.6%) with improved sensitivity and specificity (80.0 and 84.6 vs. 52.5 and 66.7%, respectively). POCUS guidance was able to rescue 89.2% of catheters that were originally noncentral. CONCLUSION POCUS implementation in a large NICU is feasible, affordable, and can improve quality of care. KEY POINTS · POCUS implementation is feasible and affordable.. · POCUS is more accurate than X-ray at monitoring UVCs.. · Central UVC placement can be increased with POCUS..
Collapse
Affiliation(s)
- John T Wren
- Division of Neonatology, Department of Pediatrics, University of Iowa Hospitals and Clinics, Iowa City, Iowa
| | - Azadeh Eslambolchi
- Division of Pediatric Radiology, Mallinckrodt Institute of Radiology, Washington University, St. Louis, Missouri
| | - Kristen Clark
- Neonatal Intensive Care Unit, Saint Louis Children's Hospital, BJC Healthcare, St. Louis, Missouri
| | - Tasnim Najaf
- Division of Newborn Medicine, Department of Pediatrics, Washington University, St. Louis, Missouri
| |
Collapse
|
3
|
Natile M, Ancora G, D'Andrea V, Pittiruti M, Barone G. A narrative review on tip navigation and tip location of central venous access devices in the neonate: Intracavitary ECG or real time ultrasound? J Vasc Access 2024:11297298241259247. [PMID: 39090995 DOI: 10.1177/11297298241259247] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/04/2024] Open
Abstract
The proper location of the tip of a central venous access device plays a crucial role in minimizing the risks potentially associated with its use. Recent guidelines strongly recommend preferring real-time, intra-procedural methods of tip location since they are more accurate, more reliable and more cost-effective than post-procedural methods. Intracavitary electrocardiography and real time ultrasound can both be applied in the neonatal setting, but they offer different advantages or disadvantages depending on the type of central venous access device. Reviewing the evidence currently available about the use of these two methods in neonates, in terms of applicability, feasibility and accuracy, it can be concluded that (a) real time ultrasound is the only acceptable methodology for tip navigation for any central venous access device in neonates, (b) intracavitary electrocardiography is the preferred method of tip location for central catheters inserted by ultrasound-guided cannulation of the internal jugular vein or the brachiocephalic vein, and (c) real time ultrasound is the preferred method of tip location for umbilical venous catheters, epicutaneo-cava catheters, and central catheters inserted by ultrasound-guided cannulation of the common femoral vein.
Collapse
Affiliation(s)
- Miria Natile
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL della Romagna, Rimini, Italy
| | - Gina Ancora
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL della Romagna, Rimini, Italy
| | - Vito D'Andrea
- Neonatal Intensive Care Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Mauro Pittiruti
- Department of Surgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Giovanni Barone
- Neonatal Intensive Care Unit, Infermi Hospital, AUSL della Romagna, Rimini, Italy
| |
Collapse
|
4
|
Rajaraman N, Gowda H. Does the use of point of care ultrasound (POCUS) improve umbilical venous catheter (UVC) positioning in neonates? Arch Dis Child 2024; 109:598-601. [PMID: 38199817 DOI: 10.1136/archdischild-2023-326653] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2023] [Accepted: 12/20/2023] [Indexed: 01/12/2024]
Affiliation(s)
- Nikitha Rajaraman
- Neonatology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, West Midlands, UK
| | - Harsha Gowda
- Neonatology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, West Midlands, UK
| |
Collapse
|
5
|
Galdo F, Trappan A, Cossovel F, Rodriguez-Perez C, Ronfani L, Montaldo P, Bibalo C, Travan L, Risso FM. Ultrasonographic measurements of the inferior vena cava diameter in newborns: is it a useful tool for choosing an umbilical venous catheter? Front Pediatr 2023; 11:1268622. [PMID: 38046676 PMCID: PMC10690934 DOI: 10.3389/fped.2023.1268622] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 10/12/2023] [Indexed: 12/05/2023] Open
Abstract
Objectives The primary outcomes of this study were to evaluate the diameters of the inferior vena cava (IVC) in a cohort of newborns and the correlation between newborn weight and IVC diameter. The secondary outcome was to evaluate the concordance between the measurements performed by the two investigators. Methods Two blind examiners performed an ultrasonographic (US) evaluation of the IVC diameter in neonates with a weight ranging from 2 to 4 kg. The exclusion criteria included hemodynamic instability, known vascular malformations, and major congenital malformations. Results A total of 143 neonates were enrolled between June 2019 and January 2021. All the US examinations were performed in the first 3 days of life. After dividing the patients into two groups according to their weight at the time of examination (2.0-2.99 kg and 3.0-4.0 kg), the median IVC diameters measured by examiner 1 were 3.1 mm (interquartile range 2.8-3.4) and 3.4 mm (interquartile range 2.9-3.8) (p = 0.003) for the two groups, respectively. The median IVC diameters measured by examiner 2 were 3.1 mm (interquartile range 2.6-3.3) and 3.3 mm (interquartile range 2.8-3.8) (p = 0.004) for the two groups, respectively. The intraclass correlation coefficient was 0.93 (95% CI: 0.90-0.95). Conclusion The IVC diameter values varied widely from 1.2 to 5.2 mm in newborns weighing 2-4 kg, and a low correlation between newborn weight and IVC diameter was found, so measuring IVC diameter may be a recommended step prior to inserting a umbilical venous catheter (UVC). The concordance between operators was good. We contemplated that the IVC diameter could be a potentially useful tool to identify the most appropriate UVC, thus reducing the risk of catheter-related thrombosis.
Collapse
Affiliation(s)
- Francesca Galdo
- Neonatal Intensive Care Unit, Institute of Child and Maternal Health, IRCSS Burlo Garofolo, Trieste, Italy
| | - Antonella Trappan
- Neonatal Intensive Care Unit, Institute of Child and Maternal Health, IRCSS Burlo Garofolo, Trieste, Italy
| | | | - Carmen Rodriguez-Perez
- Neonatology and Neonatal Intensive Care Unit, ASST Spedali Civili, Ospedale Dei Bambini, Brescia, Italy
| | - Luca Ronfani
- Clinical Epidemiology and Public Health Research Unit, Institute for Maternal and Child Health—IRCCS “Burlo Garofolo,”Trieste, Italy
| | - Paolo Montaldo
- Department of Neonatal Intensive Care, Università degli Studi della Campania Luigi Vanvitelli, Naples, Italy
- Department of Brain Sciences, Centre for Perinatal Neuroscience, Imperial College, London, United Kingdom
| | - Cristina Bibalo
- Azienda Sanitaria Universitaria Giuliano Isontino, Trieste, Italy
| | - Laura Travan
- Neonatal Intensive Care Unit, Institute of Child and Maternal Health, IRCSS Burlo Garofolo, Trieste, Italy
| | - Francesco Maria Risso
- Neonatology and Neonatal Intensive Care Unit, ASST Spedali Civili, Ospedale Dei Bambini, Brescia, Italy
| |
Collapse
|
6
|
Arnold J, Vijayakumar N, Levy P. Advanced imaging and modeling in neonatal simulation. Semin Perinatol 2023; 47:151825. [PMID: 37940437 DOI: 10.1016/j.semperi.2023.151825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2023]
Abstract
Advances in modeling and imaging have resulted in realistic tools that can be applied to education and training, and even direct patient care. These include point-of-care ultrasound (POCUS), 3-dimensional and digital anatomic modeling, and extended reality. These technologies have been used for the preparation of complex patient care through simulation-based clinical rehearsals, direct patient care such as the creation of patient devices and implants, and for simulation-based education and training for health professionals, patients and families. In this section, we discuss these emerging technologies and describe how they can be utilized to improve patient care.
Collapse
|
7
|
Tasker RC. Editor's Choice Articles for November. Pediatr Crit Care Med 2023; 24:890-892. [PMID: 37916877 DOI: 10.1097/pcc.0000000000003390] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2023]
Affiliation(s)
- Robert C Tasker
- orcid.org/0000-0003-3647-8113
- Department of Anesthesiology, Critical Care and Pain Medicine, Boston Children's Hospital, Boston, MA
- Selwyn College, Cambridge University, Cambridge, United Kingdom
| |
Collapse
|
8
|
Torres Del Pino M, Gómez Santos E, Domínguez Quintero ML, Mendoza Murillo B, Millán Zamorano JA, Toledo Muñoz-Cobo G, Mora Navarrocor D. Steps to improve umbilical vein catheterization in neonatal care. An Pediatr (Barc) 2023; 99:155-161. [PMID: 37658020 DOI: 10.1016/j.anpede.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2023] [Accepted: 06/21/2023] [Indexed: 09/03/2023] Open
Abstract
INTRODUCTION In neonatal units, umbilical vessel catheterization is the preferred method to gain vascular access in the initial management of the newborn because it is quick and easy. The failure rate ranges from to 50%, as the catheter can be found in the portal system in up to 40% of cases, leading to complications. This failure rate warrants the investigation of different methods to reduce the frequency of catheter malposition. We describe different techniques to improve the success rate in umbilical vein catheterization, such as the double catheter technique, positioning the newborn in right lateral decubitus for insertion, liver compression, and ultrasound-guided catheter insertion. The primary objective of the study was to assess the impact of new techniques on the success rate of central umbilical venous catheterization. MATERIAL AND METHODS Pre- and post-intervention quasi-experimental study in a level B NICU conducted in January-June 2022 (pre-intervention) and July-December 2022 (post-intervention). RESULTS Prior to the introduction of these new catheterization techniques, the failure rate of blind umbilical catheter insertion was 52%. Since the introduction of these measures, the overall failure rate has decreased to 27%. CONCLUSIONS After the introduction of the new catheterization and recanalization methods, our success rate in umbilical vein catheterization has increased, and we believe it is necessary to implement them in units with similar failure rates to ours.
Collapse
Affiliation(s)
- Marta Torres Del Pino
- Unidad de Neonatología, Servicio de Pediatría, Hospital Juan Ramón Jiménez, Huelva, Spain.
| | - Elisabet Gómez Santos
- Unidad de Neonatología, Servicio de Pediatría, Hospital Juan Ramón Jiménez, Huelva, Spain
| | | | | | | | | | - David Mora Navarrocor
- Unidad de Neonatología, Servicio de Pediatría, Hospital Juan Ramón Jiménez, Huelva, Spain
| |
Collapse
|
9
|
Contemporary Use of Ultrasonography in Acute Care Pediatrics. Indian J Pediatr 2023; 90:459-469. [PMID: 36897471 DOI: 10.1007/s12098-023-04475-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 01/03/2023] [Indexed: 03/11/2023]
Abstract
Use of ultrasonography by clinicians at the point of care has expanded widely and rapidly. Pediatric acute care providers now leverage this valuable tool to guide procedures, diagnose pathophysiologic processes, and inform time-sensitive decisions in sick and unstable children. However, the deployment of any new technology must be packaged with training, protocols, and safeguards to optimize safety for patients, providers, and institutions. As ultrasonography is increasingly incorporated into residency, fellowship, and even medical student curricula, it is important that educators and trainees are aware of the diversity of its clinical applications. This article aims to review the current state of point-of-care ultrasonography in acute care pediatrics, with an emphasis on the literature supporting the use of this important clinical tool.
Collapse
|
10
|
|
11
|
Editor's Choice Articles for May. Pediatr Crit Care Med 2022; 23:339-340. [PMID: 35583614 DOI: 10.1097/pcc.0000000000002966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|