1
|
Maïmoun L, Gelis A, Serrand C, Mura T, Brabant S, Garnero P, Mariano-Goulart D, Fattal C. Whole-body vibration may not affect bone mineral density and bone turnover in persons with chronic spinal cord injury: A preliminary study. J Spinal Cord Med 2025; 48:259-271. [PMID: 37930641 PMCID: PMC11864013 DOI: 10.1080/10790268.2023.2268893] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2023] Open
Abstract
CONTEXT Spinal-cord injury (SCI) induces bone loss and dramatically increases the risk of fracture. OBJECTIVES Determine the effects of whole-body vibration (WBV) on areal bone mineral density (aBMD), whole body composition and bone biological parameters in individuals with chronic-state SCI. DESIGN Randomized study. SETTING Centre Neurologique PROPARA. PARTICIPANTS Fourteen subjects were randomly assigned to a WBV or a control group. INTERVENTIONS WBV (20-45 min, 30-45 Hz, 0.5 g) was performed in verticalized persons twice weekly for 6 months. OUTCOME MEASURES aBMD was measured by DXA at baseline and 6 months and bone biological parameters at baseline, 1, 3 and 6 months. RESULTS No significant aBMD change was found in either the WBV or control group after 6 months of follow-up. Similarly, periostin, sclerostin and bone turnover markers remained relatively stable throughout follow-up and no difference in variation was observed within-group and between groups. Except for whole-body fat mass, which showed a significant decrease in the WBV group compared to controls, no difference in changes was observed, whatever the localization for fat and lean body mass. CONCLUSIONS During the chronic phase, aBMD and bone remodeling reach a new steady state. However, the DXA technique and the bone markers, including sclerostin and periostin, both of which reflect bone cell activity influenced by mechanical strain, showed that the bone tissue of individuals with SCI was insensitive to 6 months of WBV training at the study dose. Nevertheless, results of this preliminary study that was underpowered need to be confirmed and other modalities of WBV may be more effective in improving aBMD of this population. TRIALS REGISTRATION N°IDRCB:2011-A00224-37.
Collapse
Affiliation(s)
- Laurent Maïmoun
- Département de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, Montpellier, France
- PhyMedExp, INSERM, CNRS, Université de Montpellier, Montpellier, France
| | | | - Chris Serrand
- Unité de Recherche Clinique et Epidémiologie, Hôpital La Colombière, CHU Montpellier, Montpellier, France
| | - Thibault Mura
- BESPIM -Hôpital Caremeau, CHRU de Nîmes, Nîmes, France
| | - Severine Brabant
- Laboratoire des Explorations Fonctionnelles, Hôpital Necker, Paris, France
| | | | - Denis Mariano-Goulart
- Département de Médecine Nucléaire, Hôpital Lapeyronie, CHU Montpellier, Montpellier, France
- PhyMedExp, INSERM, CNRS, Université de Montpellier, Montpellier, France
| | | |
Collapse
|
2
|
Masselink CE, Detterbeck A, LaBerge NB, Paleg G. RESNA and CTF position on the application of supported standing devices: Current state of the literature. Assist Technol 2024; 37:257-274. [PMID: 39446080 DOI: 10.1080/10400435.2024.2411560] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/25/2024] [Indexed: 10/25/2024] Open
Abstract
Supported standing devices are often used to maintain a standing position by people with difficulty or inability to ambulate or stand for a period of time. Supported standing programs are first implemented by healthcare professionals with goals to impact health and function. This paper intends to update previous position on wheelchair standing devices by the Rehabilitation Engineering and Assistive Technology Association of North America, and was written in conjunction with the Clinician Task Force. The current paper expands the previous focus on wheelchair standing devices to all types of supported standing devices. A scoping review methodology found 42 studies examining outcomes of supported standing programs in the International Classification of Functioning, Disability, and Health framework in five areas of body functions, seven areas of activities and participation, and one body structure. Patterns in outcomes related to standing device type, as dynamic, or mobile, standing devices contributed to independent daily activity performance and static standing devices impacted neuromuscular capacity. Studies support engaging consistently in supported standing from nine months of age, or as soon after onset of ambulatory disability as possible, to maximize benefits. Clinical reasoning is required to apply the information in this document to unique individual cases.
Collapse
Affiliation(s)
- Cara E Masselink
- Occupational Therapy Department, Western Michigan University, Kalamazoo, Michigan, USA
| | - Ashley Detterbeck
- Clinical Education Department, Permobil Inc., Lebanon, Tennessee, USA
| | | | - Ginny Paleg
- Department of CanChild, Physical Therapy, Montgomery County Infants and Toddlers, Rockville, Maryland, USA
| |
Collapse
|
3
|
Steele AG, Vette AH, Martin C, Masani K, Sayenko DG. Synergistic effects of transcutaneous spinal stimulation and neuromuscular electrical stimulation on lower limb force production: Time to deliver. PLoS One 2024; 19:e0296613. [PMID: 39213293 PMCID: PMC11364223 DOI: 10.1371/journal.pone.0296613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2023] [Accepted: 08/09/2024] [Indexed: 09/04/2024] Open
Abstract
BACKGROUND Transcutaneous spinal stimulation (TSS) and neuromuscular electrical stimulation (NMES) can facilitate self-assisted standing in individuals with paralysis. However, individual variability in responses to each modality may limit their effectiveness in generating the necessary leg extension force for full body weight standing. To address this challenge, we proposed combining TSS and NMES to enhance leg extensor muscle activation, with optimizing timing adjustment to maximize the interaction between the two modalities. METHODS To assess the effects of TSS and NMES on knee extension and plantarflexion force, ten neurologically intact participants underwent three conditions: (1) TSS control, (2) NMES control, and (3) TSS + NMES. TSS was delivered between the T10 and L2 vertebrae, while NMES was delivered to the skin over the right knee extensors and plantarflexors. TSS and NMES were administered using a 15 Hz train of three 0.5 ms biphasic pulses. During the TSS + NMES condition, the timing between modalities was adjusted in increments of ¼ the interval within a 15 Hz frequency, i.e., 66, 49.5, 33, 16.5, and 1 ms. RESULTS NMES combined with TSS, produced synergistic effects even on non-targeted muscle groups, thereby promoting leg extension across multiple joints in the kinematic chain. The sequence of NMES or TSS trains relative to each other did not significantly impact motor output. Notably, a delay of 16.5 to 49.5 ms between interleaved TSS and NMES pulses, each delivered at 15 Hz, results in more robust and synergistic responses in knee extensors and plantarflexors. CONCLUSIONS By adjusting the timing between TSS and NMES, we can optimize the combined use of these modalities for functional restoration. Our findings highlight the potential of integrated TSS and NMES protocols to enhance motor function, suggesting promising avenues for therapeutic applications, particularly in the rehabilitation of individuals with SCI.
Collapse
Affiliation(s)
- Alexander G. Steele
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, Houston, Texas, United States of America
| | - Albert H. Vette
- Department of Mechanical Engineering, Donadeo Innovation Centre for Engineering, University of Alberta, Edmonton, Alberta, Canada
- Glenrose Rehabilitation Hospital, Alberta Health Services, Edmonton, Alberta, Canada
| | - Catherine Martin
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, Houston, Texas, United States of America
| | - Kei Masani
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON, Canada
- KITE Research Institute–University Health Network, Toronto, ON, Canada
| | - Dimitry G. Sayenko
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, Houston, Texas, United States of America
| |
Collapse
|
4
|
Steele AG, Vette AH, Martin C, Masani K, Sayenko DG. Combining transcutaneous spinal stimulation and functional electrical stimulation increases force generated by lower limbs: When more is more. BIORXIV : THE PREPRINT SERVER FOR BIOLOGY 2023:2023.12.22.573119. [PMID: 38187778 PMCID: PMC10769419 DOI: 10.1101/2023.12.22.573119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2024]
Abstract
Background Transcutaneous Spinal Stimulation (TSS) has been shown to promote activation of the lower limb and trunk muscles and is being actively explored for improving the motor outcomes of people with neurological conditions. However, individual responses to TSS vary, and often the muscle responses are insufficient to produce enough force for self-supported standing. Functional electrical stimulation (FES) can activate individual muscles and assist in closing this functional gap, but it introduces questions regarding timing between modalities. Methods To assess the effects of TSS and FES on force generation, ten neurologically intact participants underwent (1) TSS only, (2) FES only, and (3) TSS + FES. TSS was delivered using four electrodes placed at T10-T11 through the L1-L2 intervertebral spaces simultaneously, while FES was delivered to the skin over the right knee extensors and plantarflexors. For all conditions, TSS and FES were delivered using three 0.5 ms biphasic square-wave pulses at 15 Hz. During the TSS + FES condition, timing between the two modalities was adjusted in increments of ¼ time between pulses (16.5 ms). Results When TSS preceded FES, a larger force production was observed. We also determined several changes in muscle activation amplitude at different relative stimulus intervals, which help characterize our finding and indicate the facilitating and inhibitory effects of the modalities. Conclusions Utilizing a delay ranging from 15 to 30 ms between stimuli resulted in higher mean force generation in both the knee and ankle joints, regardless of the selected FES location (Average; knee: 112.0%, ankle: 103.1%).
Collapse
Affiliation(s)
- Alexander G Steele
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, 6550 Fannin Street, Houston, Texas, 77030, United States of America
| | - Albert H Vette
- Department of Mechanical Engineering, University of Alberta, Donadeo Innovation Centre for Engineering, 9211-116 Street NW, Edmonton, Alberta T6G 1H9, Canada
- Glenrose Rehabilitation Hospital, Alberta Health Services, 10230 111 Avenue NW, Edmonton, Alberta T5G 0B7, Canada
| | - Catherine Martin
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, 6550 Fannin Street, Houston, Texas, 77030, United States of America
| | - Kei Masani
- Institute of Biomedical Engineering, University of Toronto, Toronto, ON M5S 3G9, Canada
- KITE Research Institute - University Health Network, Toronto, ON M4G 3V9, Canada
| | - Dimitry G Sayenko
- Department of Neurosurgery, Center for Neuroregeneration, Houston Methodist Research Institute, 6550 Fannin Street, Houston, Texas, 77030, United States of America
| |
Collapse
|
5
|
Zoulias ID, Armengol M, Poulton A, Andrews B, Gibbons R, Harwin WS, Holderbaum W. Novel instrumented frame for standing exercising of users with complete spinal cord injuries. Sci Rep 2019; 9:13003. [PMID: 31506460 PMCID: PMC6736978 DOI: 10.1038/s41598-019-49237-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2018] [Accepted: 08/15/2019] [Indexed: 11/10/2022] Open
Abstract
This paper describes a Functional Electrical Stimulation (FES) standing system for rehabilitation of bone mineral density (BMD) in people with Spinal Cord Injury (SCI). BMD recovery offers an increased quality of life for people with SCI by reducing their risk of fractures. The standing system developed comprises an instrumented frame equipped with force plates and load cells, a motion capture system, and a purpose built 16-channel FES unit. This system can simultaneously record and process a wide range of biomechanical data to produce muscle stimulation which enables users with SCI to safely stand and exercise. An exergame provides visual feedback to the user to assist with upper-body posture control during exercising. To validate the system an alternate weight-shift exercise was used; 3 participants with complete SCI exercised in the system for 1 hour twice-weekly for 6 months. We observed ground reaction forces over 70% of the full body-weight distributed to the supporting leg at each exercising cycle. Exercise performance improved for each participant by an increase of 13.88 percentage points of body-weight in the loading of the supporting leg during the six-month period. Importantly, the observed ground reaction forces are of higher magnitude than other studies which reported positive effects on BMD. This novel instrumentation aims to investigate weight bearing standing therapies aimed at determining the biomechanics of lower limb joint force actions and postural kinematics.
Collapse
Affiliation(s)
| | - Monica Armengol
- School of Biological Sciences, University of Reading, Reading, UK
| | - Adrian Poulton
- School of Computing and Communications, Open University, Milton Keynes, UK
| | - Brian Andrews
- Nuffield Department of Surgical Sciences, Oxford, UK.,School of Engineering, University of Warwick, Warwick, UK
| | - Robin Gibbons
- Aspire CREATe, University College London, London, UK
| | - William S Harwin
- School of Biological Sciences, University of Reading, Reading, UK
| | - William Holderbaum
- School of Biological Sciences, University of Reading, Reading, UK.,School of Engineering, Metropolitan University of Manchester, Manchester, UK
| |
Collapse
|
6
|
Martinez SA, Nguyen ND, Bailey E, Doyle-Green D, Hauser HA, Handrakis JP, Knezevic S, Marett C, Weinman J, Romero AF, Santiago TM, Yang AH, Yung L, Asselin PK, Weir JP, Kornfeld SD, Bauman WA, Spungen AM, Harel NY. Multimodal cortical and subcortical exercise compared with treadmill training for spinal cord injury. PLoS One 2018; 13:e0202130. [PMID: 30092092 PMCID: PMC6084979 DOI: 10.1371/journal.pone.0202130] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Accepted: 06/25/2018] [Indexed: 12/20/2022] Open
Abstract
BACKGROUND AND PURPOSE Spared fibers after spinal cord injury (SCI) tend to consist predominantly of subcortical circuits that are not under volitional (cortical) control. We aim to improve function after SCI by using targeted physical exercises designed to simultaneously stimulate cortical and spared subcortical neural circuits. METHODS Participants with chronic motor-incomplete SCI enrolled in a single-center, prospective interventional crossover study. Participants underwent 48 sessions each of weight-supported robotic-assisted treadmill training and a novel combination of balance and fine hand exercises, in randomized order, with a 6-week washout period. Change post-intervention was measured for lower extremity motor score, soleus H-reflex facilitation; seated balance function; ambulation; spasticity; and pain. RESULTS Only 9 of 21 enrolled participants completed both interventions. Thirteen participants completed at least one intervention. Although there were no statistically significant differences, multimodal training tended to increase short-interval H-reflex facilitation, whereas treadmill training tended to improve dynamic seated balance. DISCUSSION The low number of participants who completed both phases of the crossover intervention limited the power of this study to detect significant effects. Other potential explanations for the lack of significant differences with multimodal training could include insufficient engagement of lower extremity motor cortex using skilled upper extremity exercises; and lack of skill transfer from upright postural stability during multimodal training to seated dynamic balance during testing. To our knowledge, this is the first published study to report seated posturography outcomes after rehabilitation interventions in individuals with SCI. CONCLUSION In participants with chronic incomplete SCI, a novel mix of multimodal exercises incorporating balance exercises with skilled upper extremity exercises showed no benefit compared to an active control program of body weight-supported treadmill training. To improve participant retention in long-term rehabilitation studies, subsequent trials would benefit from a parallel group rather than crossover study design.
Collapse
Affiliation(s)
| | - Nhuquynh D. Nguyen
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Eric Bailey
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Denis Doyle-Green
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Henry A. Hauser
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - John P. Handrakis
- James J. Peters VA Medical Center, Bronx, New York, United States of America
- New York Institute of Technology, Old Westbury, New York, United States of America
| | - Steven Knezevic
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Casey Marett
- New York Institute of Technology, Old Westbury, New York, United States of America
| | - Jennifer Weinman
- New York Institute of Technology, Old Westbury, New York, United States of America
| | - Angelica F. Romero
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Tiffany M. Santiago
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Ajax H. Yang
- James J. Peters VA Medical Center, Bronx, New York, United States of America
- Icahn School of Medicine at Mount Sinai, New York, New York, United States of America
| | - Lok Yung
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Pierre K. Asselin
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - Joseph P. Weir
- University of Kansas, Lawrence, Kansas, United States of America
| | - Stephen D. Kornfeld
- James J. Peters VA Medical Center, Bronx, New York, United States of America
| | - William A. Bauman
- James J. Peters VA Medical Center, Bronx, New York, United States of America
- Icahn School of Medicine at Mount Sinai, New York, New York, United States of America
| | - Ann M. Spungen
- James J. Peters VA Medical Center, Bronx, New York, United States of America
- Icahn School of Medicine at Mount Sinai, New York, New York, United States of America
| | - Noam Y. Harel
- James J. Peters VA Medical Center, Bronx, New York, United States of America
- Icahn School of Medicine at Mount Sinai, New York, New York, United States of America
- * E-mail:
| |
Collapse
|
7
|
Long-Term Performance and User Satisfaction With Implanted Neuroprostheses for Upright Mobility After Paraplegia: 2- to 14-Year Follow-Up. Arch Phys Med Rehabil 2017; 99:289-298. [PMID: 28899825 DOI: 10.1016/j.apmr.2017.08.470] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 07/21/2017] [Accepted: 08/06/2017] [Indexed: 11/22/2022]
Abstract
OBJECTIVE To quantify the long-term (>2y) effects of lower extremity (LE) neuroprostheses (NPs) for standing, transfers, stepping, and seated stability after spinal cord injury. DESIGN Single-subject design case series with participants acting as their own concurrent controls, including retrospective data review. SETTING Hospital-based clinical biomechanics laboratory with experienced (>20y in the field) research biomedical engineers, a physical therapist, and medical monitoring review. PARTICIPANTS Long-term (6.2±2.7y) at-home users (N=22; 19 men, 3 women) of implanted NPs for trunk and LE function with chronic (14.4±7.1y) spinal cord injury resulting in full or partial paralysis. INTERVENTIONS Technical and clinical performance measurements, along with user satisfaction surveys. MAIN OUTCOME MEASURES Knee extension moment, maximum standing time, body weight supported by lower extremities, 3 functional standing tasks, 2 satisfaction surveys, NP usage, and stability of implanted components. RESULTS Stimulated knee extension strength and functional capabilities were maintained, with 94% of implant recipients reporting being very or moderately satisfied with their system. More than half (60%) of the participants were still using their implanted NPs for exercise and function for >10min/d on nearly half or more of the days monitored; however, maximum standing times and percentage body weight through LEs decreased slightly over the follow-up interval. Stimulus thresholds were uniformly stable. Six-year survival rates for the first-generation implanted pulse generator (IPG) and epimysial electrodes were close to 90%, whereas those for the second-generation IPG along with the intramuscular and nerve cuff electrodes were >98%. CONCLUSIONS Objective and subjective measures of the technical and clinical performances of implanted LE NPs generally remained consistent for 22 participants after an average of 6 years of unsupervised use at home. These findings suggest that implanted LE NPs can provide lasting benefits that recipients value.
Collapse
|
8
|
Felter C. Whole Body Vibration for People with Spinal Cord Injury: a review. CURRENT PHYSICAL MEDICINE AND REHABILITATION REPORTS 2017. [DOI: 10.1007/s40141-017-0155-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
9
|
Dicianno BE, Morgan A, Lieberman J, Rosen L. Rehabilitation Engineering & Assistive Technology Society (RESNA) position on the application of wheelchair standing devices: 2013 current state of the literature. Assist Technol 2016; 28:57-62. [DOI: 10.1080/10400435.2015.1113837] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022] Open
|
10
|
Paleg G, Livingstone R. Systematic review and clinical recommendations for dosage of supported home-based standing programs for adults with stroke, spinal cord injury and other neurological conditions. BMC Musculoskelet Disord 2015; 16:358. [PMID: 26576548 PMCID: PMC4650310 DOI: 10.1186/s12891-015-0813-x] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/14/2015] [Accepted: 11/12/2015] [Indexed: 11/19/2022] Open
Abstract
Background Sitting for more than 8 h a day has been shown to negatively impact health and mortality while standing is the recommended healthier alternative. Home-based standing programs are commonly recommended for adults who cannot stand and/or walk independently. The aim of this systematic review is to review effectiveness of home-based standing programs for adults with neurological conditions including stroke and spinal cord injury; and to provide dosage guidelines to address body structure and function, activity and participation outcomes. Methods Eight electronic databases were searched, including Cochrane Library databases, MEDLINE, CINAHL and EMBASE. From 376 articles, 36 studies addressing impact of a standing intervention on adults with sub-acute or chronic neurological conditions and published between 1980 and September 2015 were included. Two reviewers independently screened titles, reviewed abstracts, evaluated full-text articles and rated quality and strength of evidence. Evidence level was rated using Oxford Centre for Evidence Based Medicine Levels and quality evaluated using a domain-based risk-of-bias rating. Outcomes were divided according to ICF components, diagnoses and dosage amounts from individual studies. GRADE and the Evidence-Alert Traffic-Lighting system were used to determine strength of recommendation and adjusted in accordance with risk-of-bias rating. Results Stronger evidence supports the impact of home-based supported standing programs on range of motion and activity, primarily for individuals with stroke or spinal cord injury while mixed evidence supports impact on bone mineral density. Evidence for other outcomes and populations is weak or very weak. Conclusions Standing should occur 30 min 5 times a week for a positive impact on most outcomes while 60 min daily is suggested for mental function and bone mineral density. Electronic supplementary material The online version of this article (doi:10.1186/s12891-015-0813-x) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Ginny Paleg
- Montgomery County Infants and Toddlers Program, Rockville, MD, USA.
| | - Roslyn Livingstone
- Sunny Hill Health Centre for Children, Vancouver, British Columbia, Canada
| |
Collapse
|
11
|
Wuermser LA, Beck LA, Lamb JL, Atkinson EJ, Amin S. The effect of low-magnitude whole body vibration on bone density and microstructure in men and women with chronic motor complete paraplegia. J Spinal Cord Med 2015; 38:178-86. [PMID: 24621040 PMCID: PMC4397199 DOI: 10.1179/2045772313y.0000000191] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/18/2023] Open
Abstract
OBJECTIVE To examine the effect of low-magnitude whole body vibration on bone density and microstructure in women and men with chronic motor complete paraplegia. METHODS We studied nine subjects (four women and five men) with motor complete paraplegia of 2 years duration or more, age 20-50 years. Subjects were instructed to stand on a low-magnitude vibration plate within a standing frame for 20 minutes per day, 5 days a week, and for 6 months. Bone density at the proximal femur by dual-energy X-ray absorptiometry and bone microstructure at the distal tibia by high-resolution peripheral quantitative computed tomography were assessed at four timepoints over 12 months (baseline, at 3 months and 6 months while on intervention, and after 6 months off intervention). RESULTS Standing on the low-magnitude vibration plate with a standing frame was well tolerated by participants. However, most subjects did not show an improvement in bone density or microstructure after 6 months of intervention, or any relevant changes 6 months following the discontinuation of the low-magnitude vibration. CONCLUSION We were unable to identify an improvement in either bone density or microstructure following 6 months use of a low-magnitude vibration plate in women or men with chronic motor complete paraplegia. Longer duration of use may be necessary, or it is possible that this intervention is of limited benefit following chronic spinal cord injury.
Collapse
Affiliation(s)
- Lisa-Ann Wuermser
- Department of Rehabilitation Medicine, Emory University School of Medicine, Atlanta, GA, USA
| | - Lisa A. Beck
- Department of Physical Medicine and Rehabilitation, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | - Jeffry L. Lamb
- Department of Physical Medicine and Rehabilitation, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | - Elizabeth J. Atkinson
- Division of Biomedical Statistics and Informatics, Department of Health Sciences Research, College of Medicine, Mayo Clinic, Rochester, MN, USA
| | - Shreyasee Amin
- Correspondence to: Shreyasee Amin, Division of Rheumatology, College of Medicine, Mayo Clinic, 200 First Street SW, Rochester, MN 55905, USA.
| |
Collapse
|
12
|
Sliding and Lower Limb Mechanics during Sit-Stand-Sit Transitions with a Standing Wheelchair. BIOMED RESEARCH INTERNATIONAL 2014; 2014:236486. [PMID: 25105120 PMCID: PMC4109664 DOI: 10.1155/2014/236486] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2014] [Revised: 04/30/2014] [Accepted: 04/30/2014] [Indexed: 11/17/2022]
Abstract
Purpose. This study aimed to investigate the shear displacement between the body and backrest/seat, range of motion (ROM), and force acting on the lower limb joints during sit-stand-sit transitions by operating an electric-powered standing wheelchair. Methods and Materials. The amounts of sliding along the backrest and the seat plane, ROM of lower limb joints, and force acting on the knee/foot were measured in twenty-four people with paraplegia. Results. Without an antishear mechanism, the shear displacement was approximately 9 cm between the user's body and the backrest/seat surfaces. During standing up, the user's back slid down and the thigh was displaced rearward, but they moved in opposite directions when wheelchair sat back down. A minimum of 60 degrees of ROM at the hip and knee was needed during sit-stand-sit transitions. The maximal resultant forces acting on the knee restraints could reach 23.5% of body weight. Conclusion. Sliding between the body and backrest/seat occurred while transitioning from sitting to standing and vice versa. A certain amount of ROM at lower limb joints and force acting on the knee was necessitated during sit-stand-sit transitions. Careful consideration needs to be given to who the user of the electric powered standing wheelchair is.
Collapse
|