1
|
Can We Apply Snyder's Arthroscopic Classification to Ultrasound for Evaluating Rotator Cuff Tears? A Comparative Study with MR Arthrography. Diagnostics (Basel) 2023; 13:diagnostics13030483. [PMID: 36766588 PMCID: PMC9914918 DOI: 10.3390/diagnostics13030483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 01/21/2023] [Accepted: 01/27/2023] [Indexed: 02/01/2023] Open
Abstract
We aimed to demonstrate the applicability of Snyder's arthroscopic classification of rotator cuff tears (RCT) in shoulder ultrasound (US) and to compare it with MR arthrography (MRA). Forty-six patients (34 males; mean age:34 ± 14 years) underwent shoulder US and MRA. Two radiologists (R1 = 25 years of experience; R2 = 2 years of experience) assigned A1-4, B1-4, or C1-4 values depending on the extent of RCT in both US and MRA. Inter-reader intra-modality and intra-reader inter-modality agreement were calculated using Cohen's kappa coefficient. US sensitivity and specificity of both readers were calculated using MRA as the gold standard. Patients were divided into intact cuff vs. tears, mild (A1/B1) vs. moderate (A2-3/B2-3) tears, mild-moderate (A2/B2) vs. high-moderate (A3/B3) cuff tears, moderate (A2-3/B2-3) vs. advanced (A4/B4) and full-thickness (C) tears. The highest agreement values in inter-reader US evaluation were observed for mild-moderate vs. high-moderate RCT (K = 0.745), in inter-reader MRA evaluation for mild vs. moderate RCT (K = 0.821), in R1 inter-modality (US-MRA) for mild-moderate vs. high-moderate and moderate vs. advanced/full-thickness RCT (K = 1.000), in R2 inter-modality (US-MRA) for moderate vs. advanced/full-thickness RCT (K = 1.000). US sensitivity ranged from 88.89%(R1)-84.62%(R2) to 100% (both readers), while specificity from 77.78%(R1)-90.00%(R2) to 100% (both readers). Snyder's classification can be used in US to ensure the correct detection and characterization of RCT.
Collapse
|
2
|
Sun Y, Xiao D, Fu W, Cai W, Huang X, Li Q, Li J. Efficacy and Safety of Tranexamic Acid in Shoulder Arthroscopic Surgery: A Systematic Review and Meta-Analysis. J Clin Med 2022; 11:6886. [PMID: 36498460 PMCID: PMC9738808 DOI: 10.3390/jcm11236886] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 11/12/2022] [Accepted: 11/19/2022] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND Visual clarity during shoulder arthroscopy can ensure an efficient and effective performance of the procedure, and it is highly related to bleeding without a tourniquet. Tranexamic acid (TXA) is widely used in adult reconstruction procedures; however, its use in shoulder arthroscopic operations is a relatively novel topic. PURPOSE To analyze the available literature on visual clarity, blood loss, pain control, functional outcomes, and complications after the administration of tranexamic acid in shoulder arthroscopic surgery. METHODS A literature search was performed to retrieve randomized controlled trials examining the use of tranexamic acid at the time of shoulder arthroscopic surgery. The literature search included the MEDLINE, Embase, Web of Science, and Cochrane Library databases. The primary outcomes included visual clarity, blood loss, and visual analog scale scores for pain. Secondary outcomes were operative time, irrigation amount used, postoperative shoulder swelling, the need for pressure increase, mean arterial pressure (MAP), functional outcomes, postoperative adverse effects such as deep venous thrombosis, and pulmonary embolism. The outcomes were pooled to perform a meta-analysis. RESULTS Seven prospective randomized controlled trials met the inclusion criteria for analysis. All of the included studies performed arthroscopic rotator cuff repair. No significant difference in visual clarity was observed (SMD (standardized mean difference), 0.45 [95% CI(confidence interval), -0.68, 1.59]; p = 0.44) nor in pain score (MD (mean difference), -0.46 [95% CI, -0.97, 0.05]; p = 0.08) between the TXA group and the control group. Two studies found no significant difference in blood loss between the TXA group and the control group. The meta-analysis from five studies demonstrated no significant difference between the TXA and control groups in operative time (MD, -3.51 [95% CI, -15.82, 8.80]; p = 0.58) or irrigation amount used (MD, -2.53 [95% CI, -5.93, 0.87]; p = 0.14). Two trials reported different statistical results in postoperative shoulder swelling. No significant differences regarding the need for pressure increase and MAP were reported between groups. No wound complications or infections or cardiac, thrombotic, or thromboembolic complications were recorded in either group. CONCLUSION The use of intravenous or local TXA in shoulder arthroscopic surgery did not increase complications or thromboembolic events, but TXA had no obviously effect of reducing bleeding to obtain a clear visual field or pain release in patients undergoing shoulder arthroscopic surgery.
Collapse
Affiliation(s)
- Yiyuan Sun
- Day Surgery Center, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Dan Xiao
- Yong Chuan Hospital of ChongQing Medical University, Chongqing 402160, China
| | - Weili Fu
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Wufeng Cai
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Xihao Huang
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Qi Li
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China
| | - Jian Li
- Department of Orthopedics, Orthopedic Research Institute, West China Hospital of Sichuan University, Chengdu 610041, China
| |
Collapse
|
3
|
Chianca V, Pietto FD, Albano D, Corvino A, Del Grande F. Ultrasound-guided percutaneous irrigation of rotator cuff calcific tendinosis. What radiologist should know. Pol J Radiol 2022; 87:e87-e92. [PMID: 35280948 PMCID: PMC8906177 DOI: 10.5114/pjr.2022.113491] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Accepted: 04/26/2021] [Indexed: 11/17/2022] Open
Abstract
Rotator cuff calcific tendinopathy is a common condition caused by the presence of calcification into the rotator cuff or in the subacromial-subdeltoid bursa. The pathogenetic mechanism of this pathology is still debated. Calcific tendinitis frequently affects the rotator cuff and may cause shoulder pain and reduction of range of motion. It can be diagnosed with conventional radiography, ultrasound, or magnetic resonance imaging. The first therapeutic option includes conservative management based on rest, physical therapy, and oral non-steroid anti-inflammatory administration. Extracorporeal shock wave therapy is a noninvasive technique that can be useful for the fragmentation of calcific deposits. Imaging-guided percutaneous irrigation is currently considered the gold standard technique for the treatment of calcific tendinitis due to its minimal invasiveness and its success rate of about 80%.
Collapse
Affiliation(s)
- Vito Chianca
- Clinica di Radiologia EOC IIMSI, Lugano, Switzerland
| | | | - Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Milano, Italy
- Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, Italy
| | - Antonio Corvino
- Motor Science and Wellness Department, University of Naples “Parthenope”, Naples, Italy
| | | |
Collapse
|
4
|
Abou Khadrah RS, Reda AM. Quantitative T2 mapping of glenohumeral joint osteoarthritis: a case-control study. THE EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE 2020. [DOI: 10.1186/s43055-020-00208-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
Abstract
Background
T2 relaxometry is a highly sensitive technique used to assess morphological changes in the cartilage prior to anatomical changes; it provides the quantification of the disparate components of cartilage such as water, proteoglycans, and collagen. This study aims to assess T2 values of glenohumeral joint cartilage using 1.5 T magnetic resonance imaging (MRI) and comparing T2 relaxation time values between two groups—the control group and the group of patients with osteoarthritis (OA). The study was conducted among 35 OA patients (27 females and eight males; median age, 60 years; age range, 43–69 years). This group was divided into primary OA (n = 15) and secondary OA (n = 20). The control group had 30 patients (25 females and five males; median age, 46 years; age range, 30–56 years). All patients were assessed using plain radiography to determine the grade of osteoarthritis followed by a multi-echo spin pulse sequence (T2 mapping) of the coronal plane. Three areas were considered to evaluate the cartilage-humeral zone, glenoid zone, and central zones by manually drawing the region of interest (ROI). The values were compared statistically by using Mann-Whitney U tests.
Results
Median T2 values differed significantly between the control group (43.4 ms [interquartile ranges, 41.54-45.33 ms]) and the OA patients for grades I (59.2 ms [interquartile ranges, 57.54-63.33 ms]), II (64.7 ms [interquartile ranges, 62.54-67.39 ms]), and III (61.9 ms, [interquartile ranges, 57.54-64.53 ms]). Mean T2 values were significantly higher in the different zones when comparing the OA patients whatever the cause primary or secondary (p value < 0.05) with the control group; no significant difference was noticed between the primary and secondary OA (p value > 0.05).
Conclusion
T2 relaxometry is a reliable, quantitative method for the assessment of the glenohumeral cartilage for significant differences in T2 values between the control group and the OA patients.
Collapse
|
5
|
Albano D, Coppola A, Gitto S, Rapisarda S, Messina C, Sconfienza LM. Imaging of calcific tendinopathy around the shoulder: usual and unusual presentations and common pitfalls. Radiol Med 2020; 126:608-619. [PMID: 33151457 PMCID: PMC8007494 DOI: 10.1007/s11547-020-01300-0] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 10/20/2020] [Indexed: 12/12/2022]
Abstract
Rotator cuff calcific tendinopathy (RCCT) is a very common condition, characterized by calcium deposition over fibrocartilaginous metaplasia of tenocytes, mainly occurring in the supraspinatus tendon. RCCT has a typical imaging presentation: in most cases, calcific deposits appear as a dense opacity around the humeral head on conventional radiography, as hyperechoic foci with or without acoustic shadow at ultrasound and as a signal void at magnetic resonance imaging. However, radiologists have to keep in mind the possible unusual presentations of RCCT and the key imaging features to correctly differentiate RCCT from other RC conditions, such as calcific enthesopathy or RC tears. Other presentations of RCCT to be considered are intrabursal, intraosseous, and intramuscular migration of calcific deposits that may mimic infectious processes or malignancies. While intrabursal and intraosseous migration are quite common, intramuscular migration is an unusual evolution of RCCT. It is important also to know atypical regions affected by calcific tendinopathy as biceps brachii, pectoralis major, and deltoid tendons. Unusual presentations of RCCT may lead to diagnostic challenge and mistakes. The aim of this review is to illustrate the usual and unusual imaging findings of RCCT that radiologists should know to reach the correct diagnosis and to exclude other entities with the purpose of preventing further unnecessary imaging examinations or interventional procedures.
Collapse
Affiliation(s)
- Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Unità Operativa di Radiologia Diagnostica ed Interventistica, Via Riccardo Galeazzi 4, 20161, Milan, Italy. .,Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, Via del Vespro 127, 90127, Palermo, Italy.
| | - Alessandra Coppola
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, 20122, Milan, Italy
| | - Salvatore Gitto
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20133, Milan, Italy
| | - Santi Rapisarda
- IRCCS Istituto Ortopedico Galeazzi, Unità Operativa di Radiologia Diagnostica ed Interventistica, Via Riccardo Galeazzi 4, 20161, Milan, Italy
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Unità Operativa di Radiologia Diagnostica ed Interventistica, Via Riccardo Galeazzi 4, 20161, Milan, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20133, Milan, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Unità Operativa di Radiologia Diagnostica ed Interventistica, Via Riccardo Galeazzi 4, 20161, Milan, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20133, Milan, Italy
| |
Collapse
|
6
|
Sconfienza LM, Albano D, Messina C, Gitto S, Guarrella V, Perfetti C, Taverna E, Arrigoni P, Randelli PS. Ultrasound-Guided Percutaneous Tenotomy of the Long Head of Biceps Tendon in Patients with Symptomatic Complete Rotator Cuff Tear: In Vivo Non-contRolled Prospective Study. J Clin Med 2020; 9:jcm9072114. [PMID: 32635548 PMCID: PMC7408901 DOI: 10.3390/jcm9072114] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2020] [Revised: 06/18/2020] [Accepted: 07/02/2020] [Indexed: 11/16/2022] Open
Abstract
Background: We prospectively tested technical feasibility and clinical outcome of percutaneous ultrasound-guided tenotomy of long head of biceps tendon (LHBT). Methods: We included 11 patients (6 women; age: 73 ± 8.6 years) with symptomatic full-thickness rotator cuff tear and intact LHBT, in whom surgical repair was not possible/refused. After ultrasound-guided injection of local anesthetic, the LHBT was cut with a scalpel under continuous ultrasound monitoring until it became no longer visible. Pain was recorded before and at least six months after procedure. An eight-item questionnaire was administered to patients at follow-up. Results: A median of 4 tendon cuts were needed to ensure complete tenotomy. Mean procedure duration was 65 ± 5.7 s. Mean length of skin incision was 5.8 ± 0.6 mm. Pre-tenotomy VAS score was 8.2 ± 0.7, post-tenotomy VAS was 2.8 ± 0.6 (p < 0.001). At follow-up, 5/11 patients were very satisfied, 5/11 satisfied and 1/11 neutral. One patient experienced cramping and very minimal pain in the biceps. Six patients had still moderate shoulder pain, 1/11 minimal pain, 2/11 very minimal pain, while 2/11 had no pain. No patients had weakness in elbow flexion nor limits of daily activities due to LHBT. One patient showed Popeye deformity. All patients would undergo ultrasound-guided tenotomy again. Conclusion: ultrasound-guided percutaneous LHBT tenotomy is technically feasible and effective.
Collapse
Affiliation(s)
- Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy; (S.G.); (P.S.R.)
| | - Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
- Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, 90127 Palermo, Italy
- Correspondence: ; Tel.: +390266214004
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy; (S.G.); (P.S.R.)
| | - Salvatore Gitto
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy; (S.G.); (P.S.R.)
| | - Vincenzo Guarrella
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
| | - Carlo Perfetti
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
| | - Ettore Taverna
- IRCCS Istituto Ortopedico Galeazzi, 20161 Milano, Italy; (L.M.S.); (C.M.); (V.G.); (C.P.); (E.T.)
| | | | - Pietro Simone Randelli
- Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, 20133 Milano, Italy; (S.G.); (P.S.R.)
- ASST Pini-CTO, 20122 Milano, Italy;
- RECAP-RD, Università degli Studi di Milano, 20133 Milano, Italy
| |
Collapse
|
7
|
Ultrasound-Guided Percutaneous Irrigation of Rotator Cuff Calcific Tendinopathy (US-PICT): Patient Experience. BIOMED RESEARCH INTERNATIONAL 2020; 2020:3086395. [PMID: 32596294 PMCID: PMC7303755 DOI: 10.1155/2020/3086395] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/15/2019] [Revised: 05/06/2020] [Accepted: 05/22/2020] [Indexed: 12/18/2022]
Abstract
Purpose To assess patients' experience of ultrasound-guided percutaneous irrigation of rotator cuff calcific tendinopathy (US-PICT). Methods Ninety-one patients (58 females; mean age: 50.5 ± 8.3 years) treated by US-PICT (local anesthesia, single-needle lavage, and intrabursal steroid injection) answered to a list of questions regarding their experience of the procedure before treatment, immediately after treatment, and three months later. The Borg CR10 scale was used to evaluate perceived pain, discomfort during anesthetic injection, and anxiety. The Wilcoxon, Spearman's rho, linear regression, and chi-square statistics were used. Results 81/91 patients complained mild discomfort during the injection of anesthetics (2, 1-2). Pain scores during US-PICT were very low (0, 0-1), with 70% patients having not experienced pain. After treatment, we found a significant reduction of pain (before: 8, 7-8; 3-month: 3, 1-6; p < .001) and anxiety (before: 5, 2-7; during treatment: 2, 1-7; p = 0.010), with high overall satisfaction (immediately after: 10, 9-10; 3-month: 9, 7-10) and confidence in the possibility of recovery (immediately after: 9, 8-10; 3-month: 10, 8-10), respectively. Treatments performed before US-PICT were not statistically associated with pain relief (p = 0.389) and clinical improvement (p = 0.937). We found a correlation between satisfaction immediately postprocedure and confidence in the possibility of recovery (p = 0.002) and between satisfaction three months after treatment and clinical improvement (p < 0.001) and patients' reminds about the description of the procedure (p = 0.005) and of the potential complications (p = 0.035). Conclusions US-PICT is a mildly painful, comfortable, and well-tolerated procedure, regardless of any previous treatments. Patients' satisfaction is correlated with clinical benefit and full explanation of the procedure and its complications.
Collapse
|
8
|
Albano D, Messina C, Sconfienza LM. Posterior Shoulder Instability: What to Look for. Magn Reson Imaging Clin N Am 2020; 28:211-221. [PMID: 32241659 DOI: 10.1016/j.mric.2019.12.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Posterior shoulder instability is often hard to diagnose with clinical examination. Patients generally present with vague pain, weakness, and/or joint clicking but less frequently complaining of frank sensation of instability. Imaging examinations, especially MR imaging and magnetic resonance arthrography, have a pivotal role in the identification and management of this condition. This review describes the pathologic micro/macrotraumatic magnetic resonance features of posterior shoulder instability as well as the underlying joint abnormalities predisposing to this condition, including developmental anomalies of the glenoid fossa, humeral head, posterior labrum, and capsular and ligamentous structures.
Collapse
Affiliation(s)
- Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, Milano 20161, Italy; Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, Via del Vespro 127, Palermo 90127, Italy
| | - Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, Milano 20161, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, Milano 20133, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Via Riccardo Galeazzi 4, Milano 20161, Italy; Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, Milano 20133, Italy.
| |
Collapse
|
9
|
Wuennemann F, Kintzelé L, Zeifang F, Maier MW, Burkholder I, Weber MA, Kauczor HU, Rehnitz C. Diagnostic performance of 3D-multi-Echo-data-image-combination (MEDIC) for evaluating SLAP lesions of the shoulder. BMC Musculoskelet Disord 2019; 20:598. [PMID: 31830984 PMCID: PMC6909556 DOI: 10.1186/s12891-019-2986-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 12/03/2019] [Indexed: 01/02/2023] Open
Abstract
Background Superior labral anterior to posterior (SLAP) lesions remain a clinical and diagnostic challenge in routine (non-arthrographic) MR examinations of the shoulder. This study prospectively evaluated the ability of 3D-Multi-Echo-Data-Image-Combination (MEDIC) compared to that of routine high resolution 2D-proton-density weighted fat-saturated (PD fs) sequence using 3 T-MRI to detect SLAP lesions using arthroscopy as gold standard. Methods Seventeen consecutive patients (mean age, 51.6 ± 14.8 years, 11 males) with shoulder pain underwent 3 T MRI including 3D-MEDIC and 2D-PD fs followed by arthroscopy. The presence or absence of SLAP lesions was evaluated using both sequences by two independent raters with 4 and 14 years of experience in musculoskeletal MRI, respectively. During arthroscopy, SLAP lesions were classified according to Snyder’s criteria by two certified orthopedic shoulder surgeons. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 3D-MEDIC and 2D-PD fs for detection of SLAP lesions were calculated with reference to arthroscopy as a gold standard. Interreader agreement and sequence correlation were analyzed using Cohen’s kappa coefficient. Figure 1 demonstrates the excellent visibility of a proven SLAP lesion using the 3D-MEDIC and Fig. 2 demonstrates a false-positive case. Results Arthroscopy revealed SLAP lesions in 11/17 patients. Using 3D-MEDIC, SLAP lesions were diagnosed in 14/17 patients by reader 1 and in 13/17 patients by reader 2. Using 2D-PD fs, SLAP lesions were diagnosed in 11/17 patients by reader 1 and 12/17 patients for reader 2. Sensitivity, specificity, PPV, and NPV of 3D-MEDIC were 100.0, 50.0, 78.6, and 100.0% for reader 1; and 100.0, 66.7, 84.6, and 100% for reader 2, respectively. Sensitivity, specificity, PPV, and NPV of 2D-PD fs were 90.9, 83.3, 90.9, and 83.3% for reader 1 and 100.0, 83.3, 91.7, and 100.0% for reader 2. The combination of 2D-PD fs and 3D-MEDIC increased specificity from 50.0 to 83.3% for reader 1 and from 66.7 to 100.0% for reader 2. Interreader agreement was almost perfect with a Cohen’s kappa of 0.82 for 3D-MEDIC and 0.87 for PD fs. Conclusions With its high sensitivity and NPV, 3D-MEDIC is a valuable tool for the evaluation of SLAP lesions. As the combination with routine 2D-PD fs further increases specificity, we recommend incorporation of 3D-MEDIC as an additional sequence in conventional shoulder protocols in patients with non-specific shoulder pain.
Collapse
Affiliation(s)
- Felix Wuennemann
- Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
| | - Laurent Kintzelé
- Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Felix Zeifang
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, University Hospital Heidelberg, Schlierbacher Landstraße 200A, 69118, Heidelberg, Germany
| | - Michael W Maier
- Center for Orthopedics, Trauma Surgery and Spinal Cord Injury, University Hospital Heidelberg, Schlierbacher Landstraße 200A, 69118, Heidelberg, Germany.,Swabian Joint Center Stuttgart, ATOS Clinic Stuttgart, Hohenheimer Straße 91, 70184, Stuttgart, Germany
| | - Iris Burkholder
- Department of Nursing and Health, University of Applied Sciences of the Saarland, Malstatter Straße 17, 66117, Saarbruecken, Germany
| | - Marc-André Weber
- Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center Rostock, Ernst-Heydemann-Straße 6, 18057, Rostock, Germany
| | - Hans-Ulrich Kauczor
- Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Christoph Rehnitz
- Diagnostic and Interventional Radiology, University Hospital Heidelberg, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| |
Collapse
|
10
|
Messina C, Albano D, Orlandi D, Chianca V, Corazza A, Ferrari F, Gitto S, Sconfienza LM. Potential use of a diluted high-relaxivity gadolinium-based intra-articular contrast agent for magnetic resonance arthrography: an in-vitro study. BMC Med Imaging 2019; 19:83. [PMID: 31653206 PMCID: PMC6815038 DOI: 10.1186/s12880-019-0387-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 10/04/2019] [Indexed: 11/10/2022] Open
Abstract
Background Magnetic resonance arthrography (MRA) requires intra-articular injection of gadolinium-based diluted paramagnetic contrast material. To our knowledge, gadobenate dimeglumine (Gd-BOPTA) has never been used for intra-articular applications. Our aim was to test in vitro different concentrations of Gd-BOPTA to be potentially used to perform MRA. Methods Gd-BOPTA was diluted in saline (NaCl 0.9%) to achieve different concentrations (4 mmol/l; 2 mmol/l; 1 mmol/l; 0.67 mmol/l; 0.5 mmol/l). Six sets of five sterile pipes were prepared with 5 ml of each solution, five sets added with 0.5 ml of fresh synovial fluid. Two separate pipes were prepared with 5 ml of gadopentetate dimeglumine (Gd-DTPA) at 2 mmol/l, one pipe added with 0.5 ml of synovial fluid. Pipes were imaged using a T1-weighted sequence at 1.5 T. For each pipe, signal intensity (SI) in arbitrary units (au) was measured. Results SI reproducibility range was 86–99%. Mean Gd-BOPTA SI in pipes containing synovial fluid increased from 1236 ± 8au (0.5 mmol/l) up to 1610 ± 44au (1 mmol/l) and down to 1405 ± 33au (4 mmol/l). Mean Gd-BOPTA SI in pipes without synovial fluid increased from 1184 ± 29au (0.5 mmol/l) up to 1530 ± 38au (1 mmol/l), and down to 1347 ± 39au (4 mmol/l). SI of pipes without synovial fluid was lower than that of pipes with synovial fluid for both Gd-BOPTA and Gd-DTPA (P ≤ 0.002). Regarding pipes with synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1246 ± 27au. Compared with Gd-BOPTA, SI was not different at 0.5 mmol/l (− 0.2%, P = 0.587) while it was higher (P < 0.001) at all other concentrations (range + 13.3%[4 mmol/l] − + 28.3%[1 mmol/l]). Regarding pipes without synovial fluid, mean Gd-DTPA SI at 2 mmol/l was 1275 ± 56au. Compared with Gd-BOPTA, SI was lower at 0.5 mmol/l (− 6.8%,P < 0.001), while it was higher (P < 0.001) at all other concentrations (range + 6.1%[4 mmol/l] − + 19.6% [1 mmol/l]). Conclusions In vitro, Gd-BOPTA at 1 mmol/ had a + 28% SI increase in comparison to Gd-DTPA 2 mmol/l. SI similar to Gd-DTPA can be obtained using one fourth concentration of Gd-BOPTA.
Collapse
Affiliation(s)
- Carmelo Messina
- IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161, Milan, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20100, Milan, Italy
| | - Domenico Albano
- IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161, Milan, Italy. .,Sezione di Scienze Radiologiche, Dipartimento di Biomedicina, Neuroscienze e Diagnostica Avanzata, Università degli Studi di Palermo, Via del Vespro 127, 90127, Palermo, Italy.
| | - Davide Orlandi
- Dipartimento di Radiologia, Ospedale Evangelico Internazionale, Piazzale Gianasso 1, 16129, Genoa, Italy
| | - Vito Chianca
- IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161, Milan, Italy
| | - Angelo Corazza
- IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161, Milan, Italy
| | - Federica Ferrari
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Salvatore Gitto
- Scuola di Specializzazione in Radiodiagnostica, Università degli Studi di Milano, Via Festa del Perdono 7, 20122, Milan, Italy
| | - Luca Maria Sconfienza
- IRCCS Istituto Ortopedico Galeazzi, Via R. Galeazzi 4, 20161, Milan, Italy.,Dipartimento di Scienze Biomediche per la Salute, Università degli Studi di Milano, Via Pascal 36, 20100, Milan, Italy
| |
Collapse
|
11
|
Zappia M, Chianca V, Di Pietto F, Reginelli A, Natella R, Maggialetti N, Albano D, Russo R, Sconfienza LM, Brunese L, Faletti C. Imaging of long head biceps tendon. A multimodality pictorial essay. ACTA BIO-MEDICA : ATENEI PARMENSIS 2019; 90:84-94. [PMID: 31085977 PMCID: PMC6625571 DOI: 10.23750/abm.v90i5-s.8351] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2019] [Indexed: 12/29/2022]
Abstract
The aim of this is article is to provide an imaging review of normal anatomy, most common anatomical variants and pathologies of the long head of the biceps tendon (LHB) encountered during the daily practice.
Collapse
Affiliation(s)
- Marcello Zappia
- Department of Medicine and Health Sciences "V. Tiberio", University of Molise, Campobasso, Italy.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|