1
|
Jin D, Li X, Qian Y, Qiao Y, Liu L, Tian J, Wang L, Ma Y, Qin Y, Zhu Y. Modified respiratory-triggered SPACE sequences for magnetic resonance cholangiopancreatography. Eur J Radiol Open 2024; 12:100564. [PMID: 38681662 PMCID: PMC11046076 DOI: 10.1016/j.ejro.2024.100564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 04/01/2024] [Accepted: 04/15/2024] [Indexed: 05/01/2024] Open
Abstract
Background Respiratory-triggered (RT) and breath-hold are the most common acquisition modalities for magnetic resonance cholangiopancreatography (MRCP). The present study compared the three different acquisition modalities for optimizing the use of MRCP in patients with diseases of the pancreatic and biliary systems. Materials and methods Three MRCP acquisition modalities were used in this study: conventional respiratory-triggered sampling perfection with application-optimized contrasts using different flip evolutions (RT-SPACE), modified RT-SPACE, and breath-hold (BH)-SPACE. Fifty-eight patients with clinically suspected pancreatic and biliary system disease were included. All image data were acquired on a 1.5 T MR. Scan time and image quality were compared between the three acquisition modalities. Friedman test, which was followed by post-hoc analysis, was performed among triple-scan protocol. Results There was a significant difference in the mean acquisition time among conventional RT-SPACE, modified RT-SPACE, and BH-SPACE (167.41±32.11 seconds vs 50.84±73.78 seconds vs 18.00 seconds, P <0.001). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were also significantly different among the three groups (P <0.001). The SNR and CNR were higher in the RT-SPACE group than in the BH-SPACE group (P <0.05). However, there were no statistically significant differences (P >0.05) among the 3 groups regarding quality of overall image, image clarity, background inhibition, and visualization of the pancreatic and biliary system. Conclusions MRCP acquisition with the modified RT-SPACE sequence greatly shortens the acquisition time with comparable quality images. The MRCP acquisition modality could be designed based on the patient's situation to improve the examination pass rate and obtain excellent images for diagnosis.
Collapse
Affiliation(s)
| | | | - Yifan Qian
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Yanqiang Qiao
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Liyao Liu
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Juan Tian
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Lei Wang
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Yongli Ma
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Yue Qin
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| | - Yinhu Zhu
- Department of Radiology, Xi’an Daxing Hospital, Xi’an, China
| |
Collapse
|
2
|
Liu K, Li Q, Wang X, Fu C, Sun H, Chen C, Zeng M. Feasibility of deep learning-reconstructed thin-slice single-breath-hold HASTE for detecting pancreatic lesions: A comparison with two conventional T2-weighted imaging sequences. RESEARCH IN DIAGNOSTIC AND INTERVENTIONAL IMAGING 2024; 9:100038. [PMID: 39076579 PMCID: PMC11265199 DOI: 10.1016/j.redii.2023.100038] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 12/26/2023] [Indexed: 07/31/2024]
Abstract
Objective The objective of this study was to evaluate the clinical feasibility of deep learning reconstruction-accelerated thin-slice single-breath-hold half-Fourier single-shot turbo spin echo imaging (HASTEDL) for detecting pancreatic lesions, in comparison with two conventional T2-weighted imaging sequences: compressed-sensing HASTE (HASTECS) and BLADE. Methods From March 2022 to January 2023, a total of 63 patients with suspected pancreatic-related disease underwent the HASTEDL, HASTECS, and BLADE sequences were enrolled in this retrospectively study. The acquisition time, the pancreatic lesion conspicuity (LCP), respiratory motion artifact (RMA), main pancreatic duct conspicuity (MPDC), overall image quality (OIQ), signal-to-noise ratio (SNR), and contrast-noise-ratio (CNR) of the pancreatic lesions were compared among the three sequences by two readers. Results The acquisition time of both HASTEDL and HASTECS was 16 s, which was significantly shorter than that of 102 s for BLADE. In terms of qualitative parameters, Reader 1 and Reader 2 assigned significantly higher scores to the LCP, RMA, MPDC, and OIQ for HASTEDL compared to HASTECS and BLADE sequences; As for the quantitative parameters, the SNR values of the pancreatic head, body, tail, and lesions, the CNR of the pancreatic lesion measured by the two readers were also significantly higher for HASTEDL than for HASTECS and BLADE sequences. Conclusions Compared to conventional T2WI sequences (HASTECS and BLADE), deep-learning reconstructed HASTE enables thin slice and single-breath-hold acquisition with clinical acceptable image quality for detection of pancreatic lesions.
Collapse
Affiliation(s)
- Kai Liu
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, Shanghai 200032, China
| | - Qing Li
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, Shanghai 200032, China
| | - Xingxing Wang
- Department of Pathology, Zhongshan Hospital, Fudan University, Shanghai 200032, China
| | - Caixia Fu
- Siemens (Shenzhen) Magnetic Resonance Ltd., Shenzhen, China
| | - Haitao Sun
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, Shanghai 200032, China
| | - Caizhong Chen
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, Shanghai 200032, China
| | - Mengsu Zeng
- Department of Radiology, Zhongshan Hospital, Fudan University, Shanghai Institute of Medical Imaging, Shanghai 200032, China
| |
Collapse
|
3
|
Yoon S, Park SH, Han D. Uncover This Tech Term: Compressed Sensing Magnetic Resonance Imaging. Korean J Radiol 2023; 24:1293-1302. [PMID: 38016687 DOI: 10.3348/kjr.2023.0743] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2023] [Revised: 09/09/2023] [Accepted: 09/10/2023] [Indexed: 11/30/2023] Open
Affiliation(s)
- Sungjin Yoon
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea
| | - So Hyun Park
- Department of Radiology, Gil Medical Center, Gachon University College of Medicine, Incheon, Republic of Korea.
| | - Dongyeob Han
- Siemens Healthineers Ltd., Seoul, Republic of Korea
| |
Collapse
|
4
|
Liu J, Li W, Li Z, Yang J, Wang K, Cao X, Qin N, Xue K, Dai Y, Wu P, Qiu J. Magnetic resonance shoulder imaging using deep learning-based algorithm. Eur Radiol 2023:10.1007/s00330-023-09470-x. [PMID: 36826500 DOI: 10.1007/s00330-023-09470-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/03/2023] [Accepted: 01/22/2023] [Indexed: 02/25/2023]
Abstract
OBJECTIVE To investigate the feasibility of deep learning-based MRI (DL-MRI) in its application in shoulder imaging and compare its performance with conventional MR imaging (non-DL-MRI). METHODS This retrospective study was approved by the local ethics committee. Seventy consecutive patients who had been examined with both DL-MRI and non-DL-MRI were enrolled for the image quality and lesion diagnosis comparison. Another 400 patients had been examined only with DL-MRI. Their images' quality was assessed by 20 radiologists using a satisfaction survey. The Kendall W test was performed to assess interobserver agreement. The Wilcoxon test was performed to compare the image quality. For lesion diagnosis, the interobserver and interstudy agreement were evaluated by kappa analysis. RESULTS The scan time of DL-MRI (6 min 1 s) was nearly 50% decreased compared with that of non-DL-MRI (11 min 25 s). The image quality was higher in both PDWI (4.85 ± 0.31 for DL, and 4.73 ± 0.29 for non-DL) and T2WI (4.95 ± 0.2 for DL, and 4.74 ± 0.41 for non-DL) of DL-MRI. Good interobserver agreement was found for the image quality of all the MR sequences on both DL-MRI (Kendall W: 0.588~0.902) and non-DL-MRI (Kendall W: 0751~0.865). Both the SNRs and |CNR| were significantly higher in PDWI and T2WI of DL-MRI. High interobserver and interstudy agreements for the lesions in non-DL-MRI and DL-MRI (kappa value = 0.913 to 1.000) were observed. The results of the image quality satisfaction survey in 400 patients receiving DL-MRI in the shoulder obtained 5 scores among all the radiologists. CONCLUSION Shoulder DL-MRI can greatly reduce the scan time, while improve imaging quality of PDWI and T2WI compared to non-DL-MRI. KEY POINTS • Shoulder 2D DL-MRI can greatly reduce the whole scan time and improve imaging quality of both PDWI and T2WI compared to conventional parallel MRI. • Shoulder 2D DL-MRI could be a clinical routine with greatly improved work efficiency in the future.
Collapse
Affiliation(s)
- Jing Liu
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Wei Li
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Ziyuan Li
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Junzhe Yang
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Ke Wang
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Xinming Cao
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Naishan Qin
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Ke Xue
- Central Research Institute, United Imaging Healthcare, 2258 Chengbei Rd., Jiading District, Shanghai, 201807, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, 2258 Chengbei Rd., Jiading District, Shanghai, 201807, China
| | - Peng Wu
- Central Research Institute, United Imaging Healthcare, 2258 Chengbei Rd., Jiading District, Shanghai, 201807, China
| | - Jianxing Qiu
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China.
| |
Collapse
|
5
|
Sui H, Gong Y, Liu L, Lv Z, Zhang Y, Dai Y, Mo Z. Comparison of Artificial Intelligence-Assisted Compressed Sensing (ACS) and Routine Two-Dimensional Sequences on Lumbar Spine Imaging. J Pain Res 2023; 16:257-267. [PMID: 36744117 PMCID: PMC9891076 DOI: 10.2147/jpr.s388219] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 12/20/2022] [Indexed: 01/29/2023] Open
Abstract
Purpose To evaluate and compare the image quality and diagnostic accuracy of Artificial Intelligence-assisted Compressed Sensing (ACS) sequences for lumbar disease, as an acceleration method for MRI combining parallel imaging, half-Fourier, compressed sensing and neural network and routine 2D sequences for lumbar spine. Methods We collected data from 82 healthy subjects and 213 patients who used 2D ACS accelerated sequences to examine the lumbar spine while 95 healthy subjects and 234 patients used routine 2D sequences. Acquisitions included axial T2WI, sagittal T2WI, T1WI, and T2-fs sequences. All obtained images of these subjects were analyzed in the light of calculating image quality factors such as signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) for selected regions of interest. The lumbar image quality, artifacts and visibility of lesion structure were assessed by two radiologists independently. Differences between the evaluation values above were tested for statistical significance by the Wilcoxon signed-ranks test. Inter-observer agreements of image quality between two radiologists were measured using Cohen's kappa correlation coefficient. Results The ACS accelerated sequences not only reduced the scanning time by 18.9%, but also retained basically the same image quality as the routine 2D sequences in both healthy subjects and patients. Artifacts are less produced on ACS accelerated sequences compared with routine 2D sequences (p < 0.05). Apart from this, there were no significant differences in quantitative SNR, CNR measurements and qualitative scores within reviewing radiologists for each group (p > 0.05). Moreover, inter-observer agreement between two radiologists in scoring image quality was substantial consistently for ACS accelerated sequences and routine sequences (kappa = 0.622-0.986). Conclusion Compared with routine 2D sequences, ACS accelerated sequences allow for faster lumbar spine imaging with similar imaging quality and present reliable diagnostic accuracy, which can potentially improve workflow and patient comfort in musculoskeletal examinations.
Collapse
Affiliation(s)
- He Sui
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Yu Gong
- Medical Imaging Department, Linyi People’s Hospital, Linyi, People’s Republic of China
| | - Lin Liu
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Zhongwen Lv
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China
| | - Yunfei Zhang
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, People’s Republic of China
| | - Yongming Dai
- MR Collaboration, Central Research Institute, United Imaging Healthcare, Shanghai, People’s Republic of China
| | - Zhanhao Mo
- Department of Radiology, China-Japan Union Hospital of Jilin University, Changchun, People’s Republic of China,Correspondence: Zhanhao Mo, Department of Radiology, China-Japan Union Hospital of Jilin University, No. 126 Xiantai St., Erdao Dist., Changchun, People’s Republic of China, Email
| |
Collapse
|
6
|
Wang K, Li X, Liu J, Guo X, Li W, Cao X, Yang J, Xue K, Dai Y, Wang X, Qiu J, Qin N. Predicting the image quality of respiratory-gated and breath-hold 3D MRCP from the breathing curve: a prospective study. Eur Radiol 2022; 33:4333-4343. [PMID: 36543903 DOI: 10.1007/s00330-022-09293-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2022] [Revised: 10/20/2022] [Accepted: 10/27/2022] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To compare the image quality of breath-hold magnetic resonance cholangiopancreatography (BH-MRCP) and respiratory-gating MRCP (RG-MRCP), and to explore breathing curve-based factors and patient-related data affecting image quality. METHODS A total of 126 participants who underwent RG-MRCP and BH-MRCP on a 3-T magnetic resonance (MR) scanner were enrolled from May to December 2021. The images were evaluated by three radiologists on a 5-point scale. Respiratory parameters were extracted from the breathing curves. The Wilcoxon test was used to compare the image quality between the two MRCPs. Logistic regression analyzes were performed to identify age, sex, abdominal pain, and breathing predictor variables of better image quality. RESULTS BH-MRCP performed better in visualizing intrahepatic bile ducts and overall image quality than RG-MRCP (p < 0.01). Factors predicting relatively good image quality included lower standard deviation of the respiratory amplitude (SDamp)-minimum-peak (odds ratio = 0.16, p < 0.01) for RG-MRCP and lower SDamp (OR = 0.69, p < 0.01) for BH-MRCP. CONCLUSIONS BH-MRCP had significantly better overall image quality than RG-MRCP. Respiratory conditions exerted a significant impact on MRCP image quality, and parameters derived from the breathing curve could help predict the image quality of both sequences. KEY POINTS • Both breath-hold (BH) and respiratory-gating (RG) MRCP demonstrate satisfying image quality. • BH-GRASE-MRCP is significantly better than RG-MRCP at the group level, but not for every individual. • Respiratory conditions exert a significant impact on the image quality, and the breathing curve can help predict the image quality.
Collapse
Affiliation(s)
- Ke Wang
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Xinying Li
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Jing Liu
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Xiaochao Guo
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Wei Li
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Xinming Cao
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Junzhe Yang
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Ke Xue
- Central Research Institute, United Imaging Healthcare, 2258 Chengbei Rd., Jiading District, Shanghai, 201807, China
| | - Yongming Dai
- Central Research Institute, United Imaging Healthcare, 2258 Chengbei Rd., Jiading District, Shanghai, 201807, China
| | - Xiaoying Wang
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China
| | - Jianxing Qiu
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China.
| | - Naishan Qin
- Department of Radiology, Peking University First Hospital, No. 8, Xishiku Street, Xicheng District, Beijing, 100034, China.
| |
Collapse
|
7
|
Qiu J, Liu J, Bi Z, Sun X, Gu Q, Hu G, Qin N. An Investigation of 2D Spine Magnetic Resonance Imaging (MRI) with Compressed Sensing (CS). Skeletal Radiol 2022; 51:1273-1283. [PMID: 34854969 DOI: 10.1007/s00256-021-03954-x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/18/2021] [Revised: 11/01/2021] [Accepted: 11/01/2021] [Indexed: 02/02/2023]
Abstract
OBJECTIVE To investigate the feasibility of compressed sensing MRI (CS-MRI) in the application of 2D spinal imaging and compare its performance with conventional MR imaging (non-CS-MRI). METHODS The CS imaging protocol was optimized on 5 volunteers. Non-CS-MRI and CS-MRI of 2D sagittal T1 weighted imaging (WI), Sag T2WI, and axial T2WI were performed for 71 patients (22 cervical, 8 thoracic, 41 lumbar MRI). Paired t tests were conducted to compare the total scan time. Three radiologists assessed image quality and lesion diagnosis independently. A Kendall W test was performed to assess interobserver agreement of the image quality scores and lesion diagnosis between readers. A nonparametric test (Wilcoxon test) was performed to compare the image quality. For lesion diagnosis, the interobserver and interstudy agreements were evaluated by kappa analysis. Paired t tests were conducted for SNR and CNR comparison. RESULTS The mean scan time for spine CS-MRI (4 min 28.7 s ± 34.6 s) was significantly shorter than that with non-CS-MRI (7 min 21.3 s ± 38.7 s, t = - 47.464, P < 0.0001). CS-MRI achieved higher SNR and CNR than Non-CS-MRI in image quality assessment. Interobserver agreements of lesion diagnosis were excellent between non-CS-MRI and CS-MRI (kappa value from 0.913 to 1.000, P < 0.001). Interstudy agreements of lesion assessments were also excellent (kappa value = 1.000, with P < 0.001). CONCLUSION CS-MRI spine imaging can significantly reduce the scan time, while maintaining comparable imaging quality to non-CS-MRI.
Collapse
Affiliation(s)
- Jianxing Qiu
- Department of Radiology, Peking University First Hospital, XiCheng District, 8 XiShiKu Avenue, Beijing, 100034, China
| | - Jing Liu
- Department of Radiology, Peking University First Hospital, XiCheng District, 8 XiShiKu Avenue, Beijing, 100034, China
| | - Zhongxu Bi
- Department of Radiology, Peking University First Hospital, XiCheng District, 8 XiShiKu Avenue, Beijing, 100034, China
| | - Xiaowei Sun
- Department of Radiology, Peking University First Hospital, XiCheng District, 8 XiShiKu Avenue, Beijing, 100034, China
| | | | - Geli Hu
- Philips Healthcare, Beijing, China
| | - Naishan Qin
- Department of Radiology, Peking University First Hospital, XiCheng District, 8 XiShiKu Avenue, Beijing, 100034, China.
| |
Collapse
|
8
|
Mahalingam N, Ralli GP, Trout AT, Dillman JR. Comparison of quantitative 3D magnetic resonance cholangiography measurements obtained using three different image acquisition methods. Abdom Radiol (NY) 2022; 47:196-208. [PMID: 34729626 DOI: 10.1007/s00261-021-03330-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Revised: 10/18/2021] [Accepted: 10/19/2021] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare quantitative biliary measurements obtained with three different magnetic resonance cholangiopancreatography (MRCP) acquisition methods. METHODS This retrospective study was IRB-approved. Patients with combinations of clinically indicated 3D FSE MRCP with sensitivity encoding (SENSE), 3D FSE SENSE MRCP with compressed sensing (CS-FSE; acceleration factor 8), and 3D gradient and spin-echo (GRASE) MRCP, acquired between October 2018 and March 2020, were included. The MRCP + Tuning Threshold algorithm (Perspectum Ltd., Oxford, UK) was used to segment 3D biliary models from MRCP data, with multiple metrics quantified from the models. Single measure, two-way, mixed-effects intra-class correlations, Bland-Altman analyses, and Wilcoxon signed-rank tests were used to compare quantitative measurements. RESULTS From 160 MRCP datasets (25 3D FSE, 67 3D CS-FSE, 68 3D GRASE) in 69 patients, 48 datasets (7 [28%] 3D FSE, 14 [21%] 3D CS-FSE, 27 [40%] 3D GRASE) failed post-processing due to motion artifacts. The remaining 112 MRCP datasets (18 3D FSE, 53 3D CS-FSE, 41 3D GRASE) from 60 patients were included in the analysis. There was good to excellent agreement between 3D FSE and 3D CS-FSE MRCP for diameter of the left and right hepatic ducts, biliary volume, number and length of ducts, and total length of dilations (ICC: 0.83-0.93). The only metrics that exhibited good agreement between 3D FSE and 3D GRASE MRCP were biliary volume (ICC: 0.75) and total number of dilations (ICC: 0.77). CONCLUSION 3D CS-FSE MRCP produces comparable biliary diameter metrics and global duct quantification to 3D FSE MRCP at a significantly reduced acquisition time.
Collapse
Affiliation(s)
- Neeraja Mahalingam
- Department of Radiology, Imaging Research Center, Cincinnati Children's Hospital Medical Center, 250 Albert Sabin Way, Cincinnati, OH, USA.
| | | | - Andrew T Trout
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
- Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| | - Jonathan R Dillman
- Department of Radiology, Imaging Research Center, Cincinnati Children's Hospital Medical Center, 250 Albert Sabin Way, Cincinnati, OH, USA
- Department of Radiology, Cincinnati Children's Hospital Medical Center, Cincinnati, OH, USA
- Department of Radiology, University of Cincinnati College of Medicine, Cincinnati, OH, USA
| |
Collapse
|
9
|
Compressed sensing for breath-hold high-resolution hepatobiliary phase imaging: image noise, artifact, biliary anatomy evaluation, and focal lesion detection in comparison with parallel imaging. Abdom Radiol (NY) 2022; 47:133-142. [PMID: 34591152 DOI: 10.1007/s00261-021-03290-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2021] [Revised: 09/17/2021] [Accepted: 09/20/2021] [Indexed: 10/20/2022]
Abstract
PURPOSE To assess image quality, performance for biliary anatomy diagnosis, and focal lesion detection rate of breath-hold high-resolution 3D T1-weighted hepatobiliary phase imaging using compressed sensing (CS HBP) compared to standard HBP using conventional parallel imaging. METHODS This retrospective study assessed consecutive 125 patients who underwent CS HBP and standard HBP between November 2019 and July 2020. Optimized resolution and scan time for CS HBP were 1 × 1.4 × 1 mm3 and 15 s, while those for standard HBP were 1.3 × 1.8 × 3 mm3 and 16 s. Two independent radiologists evaluated qualitative indices on the clarity of liver margin, visibility of the hepatic vessel and bile duct, image noise, and artifact on a 5-point scale. Biliary anatomy, confidence for biliary anatomy diagnosis, expected number of bile duct openings, and number of focal lesions were assessed. Wilcoxon signed-rank test, Pearson chi-square test, and sensitivity for focal lesion were used for statistical analysis. Intraclass correlation coefficient (ICC) and Cohen's kappa (κ) were used to determine inter-observer agreement. RESULTS CS HBP showed significantly better liver edge sharpness and bile duct visualization, but greater subjective image noise and non-respiratory artifacts compared to standard HBP. CS HBP showed higher number of concordantly assigned biliary anatomy across readers (86 vs. 80), indicating greater inter-observer agreement for biliary anatomy (κ, 0.67 vs. 0.45) and the number of bile duct openings (ICC, 0.860 vs. 0.579) with significantly higher diagnostic confidence (4.70-4.74 vs. 3.96-4.55; p = 0.002). Both readers identified more focal lesions in CS HBP than in standard HBP (88.2% and 84.5% vs. 66.3% and 73.4%). CONCLUSION Breath-hold high-resolution CS HBP was a feasible clinical sequence providing superior liver edge sharpness, bile duct visualization, and focal lesion detection rate compared to standard HBP despite higher noise and artifact. Due to improved spatial resolution, CS HBP yielded a higher inter-observer agreement and confidence for the biliary anatomy diagnosis.
Collapse
|
10
|
He M, Xu J, Wu Q, Wang X, Ren J, Wang X, Xue H, Jin Z. Application of Compressed Sensing 3D MR cholangiopancreatography (CS-MRCP) with Contact-Free Physiological Monitoring (CFPM) for Pancreaticobiliary Disorders. Acad Radiol 2021; 28 Suppl 1:S148-S156. [PMID: 34756818 DOI: 10.1016/j.acra.2020.12.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 12/08/2020] [Accepted: 12/14/2020] [Indexed: 10/19/2022]
Abstract
RATIONAL AND OBJECTIVES To prospectively evaluate the clinical feasibility of the magnetic resonance cholangiopancreatography (MRCP) protocol using both contact-free physiological monitoring (CFPM) and compressed sensing (CS) (CS-CFPM-MRCP) and to compare its performance with that of the standard navigator-triggered (NT) CS-NT-MRCP and NT-MRCP. MATERIALS AND METHODS A total of 63 patients (36 males, 27 females, age range: 18-83 years, mean age: 52.30 ± 15.70 years) suspected with duct-related pathologies were prospectively enrolled and performed the three MRCP protocols randomly. The acquisition time was compared. The pancreaticobiliary system was divided into 12 segments and evaluated based on a five-point Likert scale and compared by the Friedman test with a post hoc test. The diagnostic performance of the 3 MRCP was evaluated by the AUC value and compared by Delong's test. The interobserver agreement was evaluated by Kendall's W test. RESULTS Compared to NT-MRCP, the acquisition time of CS-NT-MRCP and CS-CFPM-MRCP was significantly decreased (both p < 0.001). There is no significant difference in the overall imaging quality (p > 0.05) between the NT-MRCP and CS-CFPM-MRCP protocols. CS-CFPM-MRCP depicted pancreatic duct and intrahepatic ducts better than CS-NT-MRCP (all p < 0.05) and was comparable with that of the NT-MRCP (all p > 0.05). For identification of abnormalities and diseases associated with MPD anatomy, the mean AUC value for NT-MRCP and CS-CFPM-MRCP were 0.896 (95%CI: 0.834, 0.958) and 0.905 (95%CI: 0.846, 0.964), which were significantly higher when compared to that for CS-NT-MRCP (0.713 [95%CI:0.622, 0.805]) (p = 0.001 and < 0.001). All evaluations showed good to excellent agreement (0.619-0.897). CONCLUSION The combination of CS and CFPM is considered feasible for shortening the scan time of 3D free breath MRCP without impairing the imaging quality and CS-CFPM-MRCP is considered feasible for patients suspected with pancreaticobiliary diseases.
Collapse
|
11
|
Single-Breath-Hold MRI-SPACE Cholangiopancreatography with Compressed Sensing versus Conventional Respiratory-Triggered MRI-SPACE Cholangiopancreatography at 3Tesla: Comparison of Image Quality and Diagnostic Confidence. Diagnostics (Basel) 2021; 11:diagnostics11101886. [PMID: 34679584 PMCID: PMC8534472 DOI: 10.3390/diagnostics11101886] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 10/06/2021] [Accepted: 10/11/2021] [Indexed: 12/20/2022] Open
Abstract
To compare two magnetic resonance cholangiopancreatography (MRCP) sequences at 3 Tesla (3T): the conventional 3D Respiratory-Triggered SPACE sequence (RT-MRCP) and a prototype 3D Compressed-Sensing Breath-Hold SPACE sequence (CS-BH-MRCP), in terms of qualitative and quantitative image quality and radiologist's diagnostic confidence for detecting common bile duct (CBD) lithiasis, biliary anastomosis stenosis in liver-transplant recipients, and communication of pancreatic cyst with the main pancreatic duct (MPD). Sixty-eight patients with suspicion of choledocholithiasis or biliary anastomosis stenosis after liver transplant, or branch-duct intraductal papillary mucinous neoplasm of the pancreas (BD-IPMN), were included. The relative CBD to peri-biliary tissues (PBT) contrast ratio (CR) was assessed. Overall image quality, presence of artefacts, background noise suppression and the visualization of 12 separated segments of the pancreatic and bile ducts were evaluated by two observers working independently on a five-point scale. Diagnostic confidence was scored on a 1-3 scale. The CS-BH-MRCP presented significantly better CRs (p < 0.0001), image quality (p = 0.004), background noise suppression (p = 0.011), fewer artefacts (p = 0.004) and better visualization of pancreatic and bile ducts segments with the exception of the proximal CBD (p = 0.054), cystic duct confluence (p = 0.459), the four secondary intrahepatic bile ducts, and central part of the MPD (p = 0.885) for which no significant differences were found. Overall, diagnostic confidence was significantly better with the CS-BH-MRCP sequence for both readers (p = 0.038 and p = 0.038, respectively). This study shows that the CS-BH-MRCP sequence presents overall better image quality and bile and pancreatic ducts visualization compared to the conventional RT-MRCP sequence at 3T.
Collapse
|
12
|
Tajima T, Akai H, Sugawara H, Yasaka K, Kunimatsu A, Yoshioka N, Akahane M, Ohtomo K, Abe O, Kiryu S. Breath-hold 3D magnetic resonance cholangiopancreatography at 1.5 T using a deep learning-based noise-reduction approach: Comparison with the conventional respiratory-triggered technique. Eur J Radiol 2021; 144:109994. [PMID: 34627106 DOI: 10.1016/j.ejrad.2021.109994] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2021] [Revised: 09/18/2021] [Accepted: 09/29/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVES To assess the image quality of conventional respiratory-triggered 3-dimentional (3D) magnetic resonance cholangiopancreatography (Resp-MRCP) and breath-hold 3D MRCP (BH-MRCP) with and without denoising procedure using deep learning-based reconstruction (dDLR) at 1.5 T. METHODS Forty-two patients underwent MRCP at 1.5 T MRI. The following imaging sequences were performed: Resp-MRCP and BH-MRCP. We applied the dDLR method to the BH-MRCP data (BH-dDLR-MRCP). As a qualitative analysis, two radiologists rated the visibility of the proximal common bile duct (CBD), pancreaticobiliary junction, distal main pancreatic duct, cystic duct, and right and left hepatic ducts. Artifacts and overall image quality were also rated. The signal-to-noise ratios (SNRs), contrast ratios, and contrast-to-noise ratios (CNRs) of the CBD images were calculated for quantitative analysis. RESULTS BH-MRCP was successfully performed in a single BH. The qualitative and quantitative measurements for BH-dDLR-MRCP were significantly higher than for BH-MRCP (P < 0.02 and P < 0.001, respectively), and the qualitative measurements for BH-dDLR-MRCP were equivalent to or higher than for Resp-MRCP (P = 0.048-1.000). The SNRs and CNRs for BH-dDLR-MRCP were significantly higher than for Resp-MRCP (P < 0.001 and P = 0.001, respectively). CONCLUSION dDLR is useful and clinically feasible for BH-MRCP at 1.5 T MRI, and enables rapid imaging without loss of image quality compared to conventional Resp-MRCP.
Collapse
Affiliation(s)
- Taku Tajima
- Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo 108-8329, Japan; Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda Narita, Chiba 286-0124, Japan
| | - Hiroyuki Akai
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo 108-8639, Japan
| | - Haruto Sugawara
- Department of Radiology, The Institute of Medical Science, The University of Tokyo, 4-6-1 Shirokanedai, Minato-ku, Tokyo 108-8639, Japan
| | - Koichiro Yasaka
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | - Akira Kunimatsu
- Department of Radiology, International University of Health and Welfare Mita Hospital, 1-4-3 Mita, Minato-ku, Tokyo 108-8329, Japan
| | - Naoki Yoshioka
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda Narita, Chiba 286-0124, Japan
| | - Masaaki Akahane
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda Narita, Chiba 286-0124, Japan
| | - Kuni Ohtomo
- International University of Health and Welfare, 2600-1 kitakanamaru, Otawara, Tochigi 324-8501, Japan
| | - Osamu Abe
- Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1, Hongo, Bunkyo-ku, Tokyo 113-0033, Japan
| | - Shigeru Kiryu
- Department of Radiology, International University of Health and Welfare Narita Hospital, 852 Hatakeda Narita, Chiba 286-0124, Japan.
| |
Collapse
|
13
|
Kim Y, Hwang J, Hong SS, Kim HJ, Chang YW, Sung J, Nickel D. Clinical Feasibility of High-Resolution Contrast-Enhanced Dynamic T1-Weighted Magnetic Resonance Imaging of the Upper Abdomen Using Compressed Sensing. J Comput Assist Tomogr 2021; 45:669-677. [PMID: 34546676 DOI: 10.1097/rct.0000000000001221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE The objective of this study was to evaluate the clinical feasibility of high-resolution contrast-enhanced dynamic T1-weighted imaging (T1WI) using compressed sensing (CS) in magnetic resonance imaging. METHODS This study retrospectively included 35 patients who underwent dynamic T1WI using volumetric interpolated breath-hold examination (VIBE) with CS reconstruction (CS-VIBE) and 35 patients with conventional VIBE for comparison. Two observers assessed the liver and pancreas edges, hepatic artery, motion artifacts, and overall image quality. Quantitative analysis was performed by measuring signal intensity and image noise. RESULTS The results showed that CS-VIBE achieved significantly better anatomic delineation of the liver and pancreas edges and hepatic artery clarity than VIBE (P < 0.001). There were no significant differences in motion artifacts in dynamic phases and overall image quality. The signal intensities and INs of CS-VIBE were higher than VIBE. CONCLUSIONS High-resolution dynamic T1WI using CS provides better anatomic delineation with comparable or better overall image quality than conventional VIBE.
Collapse
Affiliation(s)
- Yeonsoo Kim
- From the Department of Radiology, Soonchunhyang University College of Medicine, Seoul Hospital
| | - Jiyoung Hwang
- From the Department of Radiology, Soonchunhyang University College of Medicine, Seoul Hospital
| | - Seong Sook Hong
- From the Department of Radiology, Soonchunhyang University College of Medicine, Seoul Hospital
| | - Hyun-Joo Kim
- From the Department of Radiology, Soonchunhyang University College of Medicine, Seoul Hospital
| | - Yun-Woo Chang
- From the Department of Radiology, Soonchunhyang University College of Medicine, Seoul Hospital
| | - JaeKon Sung
- Siemens Healthineers Ltd, Seoul, Republic of Korea
| | - Dominik Nickel
- Application Development, Siemens Healthcare GmbH, Erlangen, Germany
| |
Collapse
|
14
|
Jiang Y, Wang X, Zhu L, Liu J, Zhang X, Hu X, Lin Z, Wang K, Qin N. Compressed-sensing accelerated magnetic resonance imaging of inner ear. J Appl Clin Med Phys 2021; 22:332-338. [PMID: 34347931 PMCID: PMC8425888 DOI: 10.1002/acm2.13383] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2021] [Revised: 07/09/2021] [Accepted: 07/21/2021] [Indexed: 12/01/2022] Open
Abstract
Objective To compare conventional method and compressed‐sensing (CS) accelerated 3D balanced fast field echo imaging (bFFE) of inner ear. Methods Twenty patients with suspected inner ear disease underwent CS accelerated 3D‐bFFE (CS‐bFFE) and conventional 3D‐bFFE (Con‐bFFE) by a 3T MRI. The overall image quality, motion artifacts, and image quality of specific structures of inner ear were assessed on ordinal scales by three radiologists who were blinded to the scan protocols. Kendall W test was used to evaluate interobserver agreement and Wilcoxon test was performed to compare the image quality and motion artifacts between CS‐bFFE and Con‐bFFE. Results The acquisition duration of CS‐bFFE (1 min 53 s) was 49% faster than Con‐bFFE. Three radiologists had good inter‐observer agreement of image quality (Kendall W value of 0.829 for CS‐bFFE and 0.815 for Con‐bFFE) and motion artifacts evaluation (Kendall W value of 0861 for CS‐bFFE and 0.707 for Con‐bFFE). The better overall image quality of CS‐bFFE was assessed (4.93 ± 0.23 for CS‐bFFE, 4.53 ± 0.70 for Con‐bFFE, Z = −2.254, p = 0.024). The image quality score of facial and cochlear nerve gained higher in CS‐bFFE (4.93 ± 0.23 for CS‐bFFE, 4.58 ± 0.64 for Con‐bFFE, Z = −2.094, p = 0.036). No significant difference of motion artifacts (p = 0.050) between CS‐bFFE and Con‐bFFE. Conclusions The CS‐bFFE improves image quality and reduces acquisition time significantly, and it is a feasible MRI protocol for inner ear imaging.
Collapse
Affiliation(s)
- Yuan Jiang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaoying Wang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Lina Zhu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Jing Liu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaodong Zhang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Xiaoyu Hu
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Zhiyong Lin
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Ke Wang
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| | - Naishan Qin
- Department of Radiology, Peking University First Hospital, Beijing, 100034, China
| |
Collapse
|
15
|
Tanabe M, Onoda H, Higashi M, Morooka R, Ihara K, Tanabe M, Matsukuma M, Iida E, Furukawa M, Ito K. Three-Dimensional (3D) Breath-Hold Zoomed MR Cholangiopancreatography (MRCP): Evaluation of Additive Value to Conventional 3D Navigator Triggering MRCP in Patients With Branch Duct Intraductal Papillary Mucinous Neoplasms. J Magn Reson Imaging 2021; 55:1234-1240. [PMID: 34331482 DOI: 10.1002/jmri.27866] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 07/20/2021] [Accepted: 07/21/2021] [Indexed: 12/28/2022] Open
Abstract
BACKGROUND To resolve drawbacks of navigator triggering (NT) three-dimensional (3D) magnetic resonance cholangiopancreatography (MRCP), several approaches were proposed to obtain 3D MRCP within a single breath-hold (BH). However, reduced field-of-view technique in the phase-encoding direction combined with two-dimensional spatially selective radiofrequency excitation pulses has not yet been applied to 3D BH MRCP. PURPOSE To investigate the feasibility and the complementary value of 3D BH zoomed MRCP to conventional 3D NT MRCP in patients with branch duct intraductal papillary mucinous neoplasms (BD-IPMNs) of the pancreas. STUDY TYPE Retrospective. POPULATION A total of 221 patients (116 male and 105 female, median age 73 years) with BD-IPMNs. FIELD STRENGTH/SEQUENCE 3.0 T/3D turbo spin echo ASSESSMENT: MR images were analyzed by three radiologists (R.M., H.O., M.T., with 1, 13, and 17 years of experience) to compare blurring and motion artifacts, background suppression, visualization of main pancreatic duct (MPD), conspicuity of BD-IPMN, and overall image quality. STATISTICAL TESTS Wilcoxon-signed rank, Mann-Whitney U, chi-squared or Fisher's exact tests (P < 0.05). RESULTS Image quality was significantly higher on 3D NT MRCP images than on 3D BH zoomed MRCP (median (interquartile range); background suppression, 4 (4-4) vs. 3 (3-4); visualization of MPD, 4 (3-4) vs. 4 (3-4), conspicuity of BD-IPMN, 4 (3-4) vs. 3 (3-4); and overall image quality, 3 (3-4) vs. 3 (3-3)). However, in 32 (14%) patients, 3D NT MRCP showed a score of 1 or 2 in overall image quality. Regarding the conspicuity of BD-IPMN, a conspicuity score of 1 or 2 was rendered in 31 (14%) patients in 3D NT MRCP group. Conversely, 3D BH zoomed MRCP showed a score of 3 or 4 in 29 (94%) of these 31 patients. DATA CONCLUSION 3D BH zoomed MRCP plays a complementary role to 3D NT MRCP, and may improve the conspicuity of BD-IPMNs in patients with irregular breathing pattern. LEVEL OF EVIDENCE 4 TECHNICAL EFFICACY: Stage 2.
Collapse
Affiliation(s)
- Masahiro Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Hideko Onoda
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Mayumi Higashi
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Ryoko Morooka
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Kenichiro Ihara
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Masaya Tanabe
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Miwa Matsukuma
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Etsushi Iida
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Matakazu Furukawa
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| | - Katsuyoshi Ito
- Department of Radiology, Yamaguchi University Graduate School of Medicine, Ube, Japan
| |
Collapse
|
16
|
Blaise H, Remen T, Ambarki K, Weiland E, Kuehn B, Orry X, Laurent V. Comparison of respiratory-triggered 3D MR cholangiopancreatography and breath-hold compressed-sensing 3D MR cholangiopancreatography at 1.5 T and 3 T and impact of individual factors on image quality. Eur J Radiol 2021; 142:109873. [PMID: 34371309 DOI: 10.1016/j.ejrad.2021.109873] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 07/02/2021] [Accepted: 07/20/2021] [Indexed: 12/20/2022]
Abstract
PURPOSE To evaluate the image quality of an accelerated compressed-sensing single-breath-hold 3D magnetic resonance cholangiopancreatography (BH-CS-MRCP) prototype sequence compared to the standard 3D sequence with respiratory triggering (STD-MRCP) at 1.5 T and 3 T. To assess the individual factors that can affect image quality. METHOD This is a retrospective analysis. Both sequences (BH-CS-MRCP and STD-MRCP) were performed in 200 patients at 1.5 T and 200 patients at 3 T. Overall image quality and the visualization of the bilio-pancreatic ducts were rated on a 5-point scale. Image sharpness and background suppression were rated on a 4-point scale. A double reading was performed in 50 patients to assess the inter-observer reproducibility. Individual characteristics studied were gender, age, BMI, ascites, abdominal surface and breath-hold quality. RESULTS At 1.5 T, BH-CS-MRCP was inferior to STD-MRCP in terms of overall quality (p = 0.0046), background suppression (p < 0.0001), visualization of the cystic duct (p < 0.0001), the right bile duct (p = 0.0008), the left bile duct (p = 0.0152), and the main pancreatic duct (p < 0.0001). However, BH-CS-MRCP was sharper than STD-MRCP (p = 0.028). At 3 T, BH-CS-MRCP was superior to STD-MRCP for overall quality (p < 0.0001), sharpness (p < 0.0001), and visualization of the bilio-pancreatic ducts (p < 0.0001). Background signal was conversely better suppressed in STD-MRCP (p < 0.0001). At 1.5 T, the volume of ascites was inversely correlated with image quality for BH-CS-MRCP while BMI was inversely correlated with image quality for STD-MRCP. Breath-hold quality was correlated with image quality for BH-CS-MRCP at 1.5 T and 3 T. CONCLUSION BH-CS-MRCP is feasible in clinical routine at 1.5 and 3 T, yielding significantly better perceived image quality at 3 T but not at 1.5 T. BH-CS-MRCP appears to be influenced by ascites whereas STD-MRCP is influenced by BMI at 1.5 T. This study was approved by the Ethics Review Board for Research in Medical Imaging (IRB: CRM-2003-065).
Collapse
Affiliation(s)
- Hélène Blaise
- Brabois Imaging Department, Nancy University Hospital, Université de Lorraine, Allée du Morvan 54500 Vandœuvre-lès-Nancy, France.
| | - Thomas Remen
- Unity of Methodology and Data Management, Nancy University Hospital, Vandœuvre-Lès-Nancy, France
| | | | | | | | - Xavier Orry
- Brabois Imaging Department, Nancy University Hospital, Université de Lorraine, Allée du Morvan 54500 Vandœuvre-lès-Nancy, France
| | - Valérie Laurent
- Brabois Imaging Department, Nancy University Hospital, Université de Lorraine, Allée du Morvan 54500 Vandœuvre-lès-Nancy, France
| |
Collapse
|
17
|
Yoen H, Lee JM, Lee SM, Kang HJ, Bae JS, Kim E, Peeters JM, Yoon JH. Comparisons between image quality and diagnostic performance of 2D- and breath-hold 3D magnetic resonance cholangiopancreatography at 3T. Eur Radiol 2021; 31:8399-8407. [PMID: 33884471 DOI: 10.1007/s00330-021-07968-w] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 03/10/2021] [Accepted: 03/31/2021] [Indexed: 11/26/2022]
Abstract
OBJECTIVES To compare the image quality and diagnostic performance of 2D MRCP to those of breath-hold 3D MRCP using compressed sensing (CS-MRCP) and gradient and spin-echo (GRASE-MRCP) at 3T. METHODS From January to November 2018, patients who underwent pancreatobiliary MRI including 2D MRCP and two breath-hold 3D MRCP using CS and GRASE at 3T were included. Three radiologists independently evaluated image quality, motion artifact, and pancreatic cyst conspicuity. Diagnostic performance was assessed for bile duct anatomic variation, bile duct, and pancreatic diseases using a composite algorithm as reference standards. Pancreatic lesion detectability and conspicuity were evaluated using JAFROC and generalized estimating equation analysis. RESULTS One hundred patients (male = 50) were included. Bile duct anatomic variation, bile duct and pancreatic diseases were present in respectively 31, 15, and 79 patients. Breath-hold 3D MRCP provided better image quality than 2D MRCP (3.5 ± 0.6 in 2D MRCP; 4.0 ± 0.7 in GRASE-MRCP and 3.9 ± 0.8 in CS-MRCP, p < 0.001 for both). There was no difference in motion artifact between 2D and breath-hold 3D MRCP (p = 0.1). Breath-hold 3D CS-MRCP provided better pancreatic cyst conspicuity than 2D MRCP (2.7 [95% CI: 2.5-3.0] vs. 2.3 [95% CI: 2.1-2.5], p = 0.001). There were no significant differences between the diagnostic performance of the three sequences in the detection of bile duct anatomic variation or pancreatic lesions (p > 0.05). CONCLUSION Breath-hold 3D MRCP with GRASE or CS can provide better image quality than 2D MRCP in a comparable scan time. KEY POINTS • Breath-hold 3D MRCP using compressed sensing (CS) or gradient and spin-echo (GRASE) provided a better image quality with less image blurring than 2D MRCP. • There were no significant differences between 2D MRCP and breath-hold 3D MRCP in either motion artifact or the number of non-diagnostic exams. • There were no significant differences between 2D MRCP and either type of breath-hold 3D MRCP in the diagnosis of bile duct anatomic variation or detection of pancreatic lesions.
Collapse
Affiliation(s)
- Heera Yoen
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
| | - Jeong Min Lee
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03087, Republic of Korea
- Institute of Radiation Medicine, Seoul National University Medical Research Center, 103 Daehak-ro, Jongno-gu, Seoul, 03087, Republic of Korea
| | - Sang Min Lee
- Department of Radiology, Hallym University Sacred Heart Hospital, Anyang, Gyunggi-do, 14068, Republic of Korea
| | - Hyo-Jin Kang
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03087, Republic of Korea
| | - Jae Seok Bae
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03087, Republic of Korea
| | - Eunju Kim
- Philips Healthcare, Seoul, 04637, Republic of Korea
| | | | - Jeong Hee Yoon
- Department of Radiology, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, 103 Daehak-ro, Jongno-gu, Seoul, 03087, Republic of Korea.
| |
Collapse
|
18
|
Shaikh S. Editorial for "Abbreviated Magnetic Resonance Imaging With Breath-Hold 3-Dimensional Magnetic Resonance Cholangiopancreatography: Assessment of Malignant Risks of Pancreatic Intraductal Papillary Mucinous Neoplasms". J Magn Reson Imaging 2021; 54:1187-1188. [PMID: 33769636 DOI: 10.1002/jmri.27616] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2021] [Accepted: 02/27/2021] [Indexed: 11/05/2022] Open
Affiliation(s)
- Sikandar Shaikh
- Department of Radiology, Shadan Institute of Medical Sciences, Hyderabad, Telangana, India.,Department of Biomedical Engineering, Indian Institute of Technology, Hyderabad, Telangana, India
| |
Collapse
|
19
|
Clinical Feasibility of Abbreviated Magnetic Resonance With Breath-Hold 3-Dimensional Magnetic Resonance Cholangiopancreatography for Surveillance of Pancreatic Intraductal Papillary Mucinous Neoplasm. Invest Radiol 2021; 55:262-269. [PMID: 32073419 DOI: 10.1097/rli.0000000000000636] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVES To determine the clinical feasibility of abbreviated magnetic resonance image (MRI) using breath-hold 3-dimensional magnetic resonance cholangiopancreatography (3D-MRCP) (aMRI-BH) for pancreatic intraductal papillary mucinous neoplasm (IPMN) surveillance. MATERIALS AND METHODS In this retrospective study, 123 patients with 158 pancreatic IPMNs (pathologically proven [n = 73] and typical image feature with ≥2-year stability [n = 85]) who underwent conventional MRI (cMRI) consisting of contrast-enhanced pancreatobiliary MRI with conventional and BH-3D-MRCP were included. Two readers independently evaluated aMRI-BH protocols consisting of heavily T2-weighted, precontrast T1-weighted, and BH-3D-MRCP sequences. The diagnostic performance of aMRI-BH for detecting malignant IPMNs was assessed using the following criteria: category 3, presence of mural nodule 5 mm or bigger and/or main pancreatic duct (MPD) 10 mm or bigger; category 2, more than one of the following: cyst size 30 mm or greater, mural nodule smaller than 5 mm, thickened cyst walls, MPD of 5 to 9 mm, lymphadenopathy, and an abrupt MPD caliber change with distal atrophy; and category 1, none of the above. Categories 2 or 3 were considered positive results of surveillance. Interreader agreement of image features by intraclass correlation and κ statistics were analyzed. RESULTS The total acquisition times of cMRI and aMRI-BH were 32.7 ± 8 and 5.5 ± 2.1 minutes, respectively (P < 0.01). Among 158 IPMNs, 33 lesions were malignant. The aMRI-BH presented a sensitivity of 100% and a negative predictive value of 100% for evaluating malignant IPMNs in both readers, with substantial interreader agreements (intraclass correlation or к values, range: 0.73-0.93 for cMRI and 0.57-0.94 for aMRI-BH) in significant imaging features based on revised Fukuoka guidelines, except for thickened cyst walls and lymphadenopathy (к values: 0.10 and 1.00 for cMRI and 0.13 and 0.49 for aMRI-BH, respectively). CONCLUSIONS The aMRI-BH provided high sensitivity and negative predictive value to evaluate malignant IPMNs by using predetermined criteria, and aMRI-BH might be a potential tool for pancreatic IPMN surveillance with significantly lower acquisition time.
Collapse
|
20
|
Hasse FC, Selmi B, Albusaidi H, Mokry T, Mayer P, Rupp C, Kauczor HU, Weber TF. Balanced steady-state free precession MRCP is a robust alternative to respiration-navigated 3D turbo-spin-echo MRCP. BMC Med Imaging 2021; 21:10. [PMID: 33430780 PMCID: PMC7802244 DOI: 10.1186/s12880-020-00532-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2020] [Accepted: 11/29/2020] [Indexed: 12/24/2022] Open
Abstract
Background Despite synchronization to respiration, respiration-navigated (RN) 3D turbo-spin-echo MRCP is limited by susceptibility to motion artifacts. The aim of this study was to assess the quality of pancreaticobiliary duct visualization of a non-RN MRCP alternative based on balanced steady-state free precession imaging (BSSFP) with overlapping slices compared with RN-MRCP.
Methods This is a retrospective study on 50 patients without pancreaticobiliary duct disease receiving MRCP at 1.5 T. We performed an intraindividual comparison of coronal RN-MRCP with combined coronal and transverse BSSFP-MRCP. Image quality was scored by 3 readers for 6 pancreaticobiliary duct segments (3 pancreatic, 3 biliary) using a 6-point scale. A segment score of 3 or lower as assessed by at least 2 of 3 readers was defined as insufficient segment visualization. Nonparametric tests and interrater reliability testing were used for statistical analysis.
Results Overall duct visualization averaged over all readers was scored with 4.5 ± 1.1 for RN-MRCP (pancreatic, 4.1 ± 0.5; biliary, 5.0 ± 0.4) and 4.9 ± 0.9 for combined coronal and transverse BSSFP-MRCP (pancreatic, 4.6 ± 0.6; biliary, 5.1 ± 0.6), respectively (p < 0.001). The number of segments visualized insufficiently was 81/300 for RN-MRCP and 43/300 for BSSFP-MRCP (p < 0.001). Segments visualized insufficiently only in RN-MRCP had a mean score of 4.4 ± 0.8 in BSSFP-MRCP. Overall interrater agreement on superiority of BSSFP-MRCP segment scores over corresponding RN-MRCP was 0.70. Mean acquisition time was 98% longer for RN-MRCP (198.0 ± 98.7 s) than for combined coronal and transverse BSSFP-MRCP (100.2 ± 0.4 s). Conclusions Non-RN BSSFP-MRCP with overlapping slices is a fast alternative to RN-MRCP, frequently providing sufficient duct visualization when RN-MRCP fails.
Collapse
Affiliation(s)
- Felix Christian Hasse
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany.
| | - Buket Selmi
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Hamed Albusaidi
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Theresa Mokry
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Philipp Mayer
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Christian Rupp
- Department of Gastroenterology, Heidelberg University Hospital, Im Neuenheimer Feld 410, 69120, Heidelberg, Germany
| | - Hans-Ulrich Kauczor
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| | - Tim Frederik Weber
- Diagnostic and Interventional Radiology, Heidelberg University Hospital, Im Neuenheimer Feld 110, 69120, Heidelberg, Germany
| |
Collapse
|
21
|
Deep Learning Approach for Generating MRA Images From 3D Quantitative Synthetic MRI Without Additional Scans. Invest Radiol 2020; 55:249-256. [PMID: 31977603 DOI: 10.1097/rli.0000000000000628] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
OBJECTIVES Quantitative synthetic magnetic resonance imaging (MRI) enables synthesis of various contrast-weighted images as well as simultaneous quantification of T1 and T2 relaxation times and proton density. However, to date, it has been challenging to generate magnetic resonance angiography (MRA) images with synthetic MRI. The purpose of this study was to develop a deep learning algorithm to generate MRA images based on 3D synthetic MRI raw data. MATERIALS AND METHODS Eleven healthy volunteers and 4 patients with intracranial aneurysms were included in this study. All participants underwent a time-of-flight (TOF) MRA sequence and a 3D-QALAS synthetic MRI sequence. The 3D-QALAS sequence acquires 5 raw images, which were used as the input for a deep learning network. The input was converted to its corresponding MRA images by a combination of a single-convolution and a U-net model with a 5-fold cross-validation, which were then compared with a simple linear combination model. Image quality was evaluated by calculating the peak signal-to-noise ratio (PSNR), structural similarity index measurements (SSIMs), and high frequency error norm (HFEN). These calculations were performed for deep learning MRA (DL-MRA) and linear combination MRA (linear-MR), relative to TOF-MRA, and compared with each other using a nonparametric Wilcoxon signed-rank test. Overall image quality and branch visualization, each scored on a 5-point Likert scale, were blindly and independently rated by 2 board-certified radiologists. RESULTS Deep learning MRA was successfully obtained in all subjects. The mean PSNR, SSIM, and HFEN of the DL-MRA were significantly higher, higher, and lower, respectively, than those of the linear-MRA (PSNR, 35.3 ± 0.5 vs 34.0 ± 0.5, P < 0.001; SSIM, 0.93 ± 0.02 vs 0.82 ± 0.02, P < 0.001; HFEN, 0.61 ± 0.08 vs 0.86 ± 0.05, P < 0.001). The overall image quality of the DL-MRA was comparable to that of TOF-MRA (4.2 ± 0.7 vs 4.4 ± 0.7, P = 0.99), and both types of images were superior to that of linear-MRA (1.5 ± 0.6, for both P < 0.001). No significant differences were identified between DL-MRA and TOF-MRA in the branch visibility of intracranial arteries, except for ophthalmic artery (1.2 ± 0.5 vs 2.3 ± 1.2, P < 0.001). CONCLUSIONS Magnetic resonance angiography generated by deep learning from 3D synthetic MRI data visualized major intracranial arteries as effectively as TOF-MRA, with inherently aligned quantitative maps and multiple contrast-weighted images. Our proposed algorithm may be useful as a screening tool for intracranial aneurysms without requiring additional scanning time.
Collapse
|
22
|
Morimoto D, Hyodo T, Kamata K, Kadoba T, Itoh M, Fukushima H, Chiba Y, Takenaka M, Mochizuki T, Ueda Y, Miyagoshi K, Kudo M, Ishii K. Navigator-triggered and breath-hold 3D MRCP using compressed sensing: image quality and method selection factor assessment. Abdom Radiol (NY) 2020; 45:3081-3091. [PMID: 31925493 DOI: 10.1007/s00261-020-02403-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE To examine whether MRCP using a combination of compressed sensing and sensitivity encoding with navigator-triggered and breath-hold techniques (NT C-SENSE and BH C-SENSE, respectively) have comparable image quality to that of navigator-triggered MRCP using only sensitivity encoding (NT SENSE) at 1.5-T. METHODS Fifty-one participants were enrolled in this prospective study between July and October 2018 and underwent the three 3D MRCP sequences each. The acquisition time and relative duct-to-periductal contrast ratios (RC values) of each bile duct segment were obtained. Visualization of the bile and main pancreatic ducts, background suppression, artifacts, and overall image quality were scored on 5-point scales. Mean and median differences in RC values and qualitative scores of NT C-SENSE and BH C-SENSE relative to NT SENSE were calculated with 95% confidence intervals (CIs). RESULTS Acquisition time of NT SENSE, NT C-SENSE, and BH C-SENSE were 348, 143 (mean for both), and 18 s (for all participants), respectively. The RC value of each bile duct segment was inferior, but the lower limits of the 95% CIs of the mean differences were ≥ - 0.10, for both NT C-SENSE and BH C-SENSE. The visualization score of the intrahepatic duct in BH C-SENSE was inferior to that in NT SENSE (lower 95% CI limit, - 1.5). In both NT C-SENSE and BH C-SENSE, the 95% CIs of the median differences in the other qualitative scores were from - 1.0 to 0.0. CONCLUSION NT C-SENSE and BH C-SENSE have comparable image quality to NT SENSE at 1.5-T.
Collapse
Affiliation(s)
- Daisuke Morimoto
- Radiology Center, Kindai University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka, Japan.
| | - Tomoko Hyodo
- Department of Radiology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| | - Ken Kamata
- Department of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| | - Tomoya Kadoba
- Department of Radiology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| | - Makoto Itoh
- Radiology Center, Kindai University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka, Japan
| | - Hiroyuki Fukushima
- Radiology Center, Kindai University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka, Japan
| | - Yasutaka Chiba
- Clinical Research Center, Kindai University Hospital, Osaka-Sayama, Osaka, Japan
| | - Mamoru Takenaka
- Department of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| | | | - Yu Ueda
- Philips Japan, Minato-ku, Tokyo, Japan
| | - Keizou Miyagoshi
- Radiology Center, Kindai University Hospital, 377-2 Ohno-Higashi, Osaka-Sayama, Osaka, Japan
| | - Masatoshi Kudo
- Department of Gastroenterology and Hepatology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| | - Kazunari Ishii
- Department of Radiology, Faculty of Medicine, Kindai University, Osaka-Sayama, Japan
| |
Collapse
|
23
|
Henninger B, Steurer M, Plaikner M, Weiland E, Jaschke W, Kremser C. Magnetic resonance cholangiopancreatography with compressed sensing at 1.5 T: clinical application for the evaluation of branch duct IPMN of the pancreas. Eur Radiol 2020; 30:6014-6021. [PMID: 32556465 PMCID: PMC7554004 DOI: 10.1007/s00330-020-06996-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2020] [Revised: 04/23/2020] [Accepted: 05/29/2020] [Indexed: 12/28/2022]
Abstract
Objectives To evaluate magnetic resonance cholangiopancreatography (MRCP) with compressed sensing (CS) for the assessment of branch duct intraductal papillary mucinous neoplasm (BD-IPMN) of the pancreas. For this purpose, conventional navigator-triggered (NT) sampling perfection with application-optimized contrast using different flip angle evolutions (SPACE) MRCP was compared with various CS-SPACE-MRCP sequences in a clinical setting. Methods A total of 41 patients (14 male, 27 female, mean age 68 years) underwent 1.5-T MRCP for the evaluation of BD-IPMN. The MRCP protocol consisted of the following sequences: conventional NT-SPACE-MRCP, CS-SPACE-MRCP with long (BHL, 17 s) and short single breath-hold (BHS, 8 s), and NT-CS-SPACE-MRCP. Two board-certified radiologists evaluated image quality, duct sharpness, duct visualization, lesion conspicuity, confidence, and communication with the main pancreatic duct in consensus using a 5-point scale (1–5), with higher scores indicating better quality/delineation/confidence. Maximum intensity projection reconstructions and originally acquired data were used for evaluation. Wilcoxon signed-rank test was used to compare the intra-individual difference between sequences. Results BHS-CS-SPACE-MRCP had the highest scores for image quality (3.85 ± 0.79), duct sharpness (3.81 ± 1.05), and duct visualization (3.81 ± 1.01). There was a significant difference compared with NT-CS-SPACE-MRCP (p < 0.05) but no significant difference to the standard NT-SPACE-MRCP (p > 0.05). Concerning diagnostic quality, BHS-CS-SPACE-MRCP had the highest scores in lesion conspicuity (3.95 ± 0.92), confidence (4.12 ± 1.08), and communication (3.8 ± 1.06), significantly higher compared with NT-SPACE-MRCP, BHL-SPACE-MRCP, and NT-CS-SPACE-MRCP (p = <0.05). Conclusions MRCP with CS 3D SPACE for the evaluation of BD-IPMN at 1.5 T provides the best results using a short breath-hold sequence. This approach is feasible and an excellent alternative to standard NT 3D MRCP sequences. Key Points • 1.5-T MRCP with compressed sensing for the evaluation of branch duct IPMN is a feasible method. • Short breath-hold sequences provide the best results for this purpose.
Collapse
Affiliation(s)
- Benjamin Henninger
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria.
| | - Michael Steurer
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| | - Michaela Plaikner
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| | | | - Werner Jaschke
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| | - Christian Kremser
- Department of Radiology, Medical University of Innsbruck, Anichstraße 35, 6020, Innsbruck, Austria
| |
Collapse
|
24
|
Optimized Breath-Hold Compressed-Sensing 3D MR Cholangiopancreatography at 3T: Image Quality Analysis and Clinical Feasibility Assessment. Diagnostics (Basel) 2020; 10:diagnostics10060376. [PMID: 32517113 PMCID: PMC7345120 DOI: 10.3390/diagnostics10060376] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Revised: 05/31/2020] [Accepted: 06/04/2020] [Indexed: 11/16/2022] Open
Abstract
Magnetic resonance cholangiopancreatography (MRCP) has been widely used in clinical practice, and recently developed compressed-sensing accelerated MRCP (CS-MRCP) has shown great potential in shortening the acquisition time. The purpose of this prospective study was to evaluate the clinical feasibility and image quality of optimized breath-hold CS-MRCP (BH-CS-MRCP) and conventional navigator-triggered MRCP. Data from 124 consecutive patients with suspected pancreaticobiliary diseases were analyzed by two radiologists using a five-point Likert-type scale. Communication between a cyst and the pancreatic duct (PD) was analyzed. Signal-to-noise ratio (SNR) of the common bile duct (CBD), contrast ratio between the CBD and periductal tissue, and contrast-to-noise ratio (CNR) of the CBD and liver were measured. Optimized BH-CS-MRCP showed significantly fewer artifacts with better background suppression and overall image quality. Optimized BH-CS-MRCP demonstrated communication between a cyst and the PD better than conventional MRCP (96.7% vs. 76.7%, p = 0.048). SNR, contrast ratio, and CNR were significantly higher with optimized BH-CS-MRCP (p < 0.001). Optimized BH-CS-MRCP showed comparable or even better image quality than conventional MRCP, with improved visualization of communication between a cyst and the PD.
Collapse
|
25
|
Technological Advances of Magnetic Resonance Imaging in Today's Health Care Environment. Invest Radiol 2020; 55:531-542. [PMID: 32487969 DOI: 10.1097/rli.0000000000000678] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Today's health care environment is shifting rapidly, driven by demographic change and high economic pressures on the system. Furthermore, modern precision medicine requires highly accurate and specific disease diagnostics in a short amount of time. Future imaging technology must adapt to these challenges.Demographic change necessitates scanner technologies tailored to the needs of an aging and increasingly multimorbid patient population. Accordingly, examination times have to be short enough that diagnostic images can be generated even for patients who can only lie in the scanner for a short time because of pain or with low breath-hold capacity.For economic reasons, the rate of nondiagnostic scans due to artifacts should be reduced as far as possible. As imaging plays an increasingly pivotal role in clinical-therapeutic decision making, magnetic resonance (MR) imaging facilities are confronted with an ever-growing number of patients, emphasizing the need for faster acquisitions while maintaining image quality.Lastly, modern precision medicine requires high and standardized image quality as well as quantifiable data in order to develop image-based biomarkers on which subsequent treatment management can rely.In recent decades, a variety of approaches have addressed the challenges of high throughput, demographic change, and precision medicine in MR imaging. These include field strength, gradient, coil and sequence development, as well as an increasing consideration of artificial intelligence. This article reviews state-of-the art MR technology and discusses future implementation from the perspective of what we know today.
Collapse
|
26
|
Ultrafast Intracranial Vessel Imaging With Non-Cartesian Spiral 3-Dimensional Time-of-Flight Magnetic Resonance Angiography at 1.5 T. Invest Radiol 2020; 55:293-303. [DOI: 10.1097/rli.0000000000000641] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
27
|
Harrington KA, Shukla-Dave A, Paudyal R, Do RKG. MRI of the Pancreas. J Magn Reson Imaging 2020; 53:347-359. [PMID: 32302044 DOI: 10.1002/jmri.27148] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 03/01/2020] [Accepted: 03/02/2020] [Indexed: 02/06/2023] Open
Abstract
MRI has played a critical role in the evaluation of patients with pancreatic pathologies, from screening of patients at high risk for pancreatic cancer to the evaluation of pancreatic cysts and indeterminate pancreatic lesions. The high mortality associated with pancreatic adenocarcinomas has spurred much interest in developing effective screening tools, with MRI using magnetic resonance cholangiopancreatography (MRCP) playing a central role in the hopes of identifying cancers at earlier stages amenable to curative resection. Ongoing efforts to improve the resolution and robustness of imaging of the pancreas using MRI may thus one day reduce the mortality of this deadly disease. However, the increasing use of cross-sectional imaging has also generated a concomitant clinical conundrum: How to manage incidental pancreatic cystic lesions that are found in over a quarter of patients who undergo MRCP. Efforts to improve the specificity of MRCP for patients with pancreatic cysts and with indeterminate pancreatic masses may be achieved with continued technical advances in MRI, including diffusion-weighted and T1 -weighted dynamic contrast-enhanced MRI. However, developments in quantitative MRI of the pancreas remain challenging, due to the small size of the pancreas and its upper abdominal location, adjacent to bowel and below the diaphragm. Further research is needed to improve MRI of the pancreas as a clinical tool, to positively affect the lives of patients with pancreatic abnormalities. This review focuses on various MR techniques such as MRCP, quantitative imaging, and dynamic contrast-enhanced imaging and their clinical applicability in the imaging of the pancreas, with an emphasis on pancreatic malignant and premalignant lesions. Level of Evidence 5 Technical Efficacy Stage 3 J. MAGN. RESON. IMAGING 2021;53:347-359.
Collapse
Affiliation(s)
- Kate A Harrington
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Amita Shukla-Dave
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA.,Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Ramesh Paudyal
- Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| | - Richard K G Do
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY, USA
| |
Collapse
|
28
|
Mannes I, Dallongeville A, Badat N, Beaussier H, Chatellier G, Zins M. Breath-hold compressed-sensing 3D MR cholangiopancreatography compared to free-breathing 3D MR cholangiopancreatography: prospective study of image quality and diagnostic performance in pancreatic disorders. Abdom Radiol (NY) 2020; 45:1082-1091. [PMID: 31598763 DOI: 10.1007/s00261-019-02254-2] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
PURPOSE To compare image quality and diagnostic performance of three magnetic resonance cholangiopancreatography (MRCP) protocols in patients with suspected pancreatic abnormalities: free-breathing standard 3D-MRCP (STD), free-breathing compressed sensing 3D-MRCP (CS), and CS 3D-MRCP with acquisition during a single breath-hold > 20 s (BH-CS). METHODS Informed consent was obtained. We performed 57 MRCPs in 56 prospectively included patients (29 men, median age 59 years). The three protocols were performed in random order. Acquisition time was recorded. Two radiologists blinded to the protocols used 5-point scales to assess image quality parameters (overall image quality, amount of artifacts, background suppression, bile and pancreatic duct visualization) and diagnostic performance (anatomical variants, duct abnormalities, cystic lesions). RESULTS Acquisition time was 279 s with STD, 176 s with CS (-37%), and 22 s with BH-CS (-93%). STD and BH-CS were not significantly different for overall image quality, artifacts, or background suppression. The BH-CS group had fewer non-diagnostic scans (3% vs. 19% with STD and 21% with CS, p < 0.05), higher-quality scans (78% vs. 66% with STD and 58% with CS, p < 0.05), and milder artifacts (2% vs. 18% with STD and 16% with CS, p < 0.05). The main pancreatic duct was better visualized with BH-CS compared to STD (p = 0.015) and CS (p < 0.001). Diagnostic performance did not differ across the three protocols. There were fewer indeterminate scans in the BH-CS group. CONCLUSION 3T BH-CS is reliable, saves time, and is not associated with decreases in image quality or diagnostic performance compared to STD and CS.
Collapse
Affiliation(s)
- Inès Mannes
- Hôpital Saint Joseph, 185 rue Raymond Losserand, 75014, Paris, France.
| | | | - Neesmah Badat
- Hôpital Saint Joseph, 185 rue Raymond Losserand, 75014, Paris, France
| | - Hélène Beaussier
- Hôpital Saint Joseph, 185 rue Raymond Losserand, 75014, Paris, France
| | - Gilles Chatellier
- Hôpital Européen Georges-Pompidou, 20 rue Leblanc, 75015, Paris, France
| | - Marc Zins
- Hôpital Saint Joseph, 185 rue Raymond Losserand, 75014, Paris, France
| |
Collapse
|
29
|
Tokoro H, Yamada A, Suzuki T, Kito Y, Adachi Y, Hayashihara H, Nickel MD, Maruyama K, Fujinaga Y. Usefulness of breath-hold compressed sensing accelerated three-dimensional magnetic resonance cholangiopancreatography (MRCP) added to respiratory-gating conventional MRCP. Eur J Radiol 2019; 122:108765. [PMID: 31830630 DOI: 10.1016/j.ejrad.2019.108765] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2019] [Revised: 10/27/2019] [Accepted: 11/20/2019] [Indexed: 10/25/2022]
Abstract
PURPOSE To clarify the clinical usefulness of breath-hold compressed sensing three-dimensional magnetic resonance cholangiopancreatography (BH-MRCP) added to conventional respiratory-gating MRCP (RG-MRCP), we prospectively evaluated the image quality of BH-MRCP and compared it with that of RG-MRCP. We also evaluated to what extent the overall image quality was improved by adding BH-MRCP to RG-MRCP. MATERIALS AND METHODS A total of 113 patients who underwent RG-MRCP and BH-MRCP at a 3-T MR unit were enrolled. We set a scan time of approximately 180 s for RG-MRCP and 20 s for BH-MRCP before examination, and measured actual scan time and assessed image quality using a 5-point scale (5, good; 1, poor). Image quality scores of 1, 2 and 3 were considered clinically inadequate. Image quality scores of RG-MRCP and BH-MRCP were compared. In addition, we compared "RG-MRCP alone" and "hybrid MRCP" (the best-scoring image was picked from RG-MRCP and BH-MRCP when the RG-MRCP score was clinically inadequate). RESULTS The mean actual scan time of RG-MRCP/BH-MRCP was 191/20 s. The mean scores of RG-MRCP, BH-MRCP and hybrid MRCP were 3.67, 3.35 and 3.92, respectively. The score of hybrid MRCP was significantly better than that of RG-MRCP (P < 0.05). The image quality of RG-MRCP was clinically inadequate in 43/113 (38 %) cases and the inadequate image quality was improved to be clinically adequate in 13/43 (30 %) cases by adding BH-MRCP. CONCLUSION BH-MRCP brings added value to RG-MRCP because an additional examination of BH-MRCP could compensate for the image deterioration of RG-MRCP caused by motion artifacts.
Collapse
Affiliation(s)
- Hirokazu Tokoro
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Akira Yamada
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Takeshi Suzuki
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Yoshihiro Kito
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Yasuo Adachi
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Hayato Hayashihara
- Radiology Division of Shinshu University Hospital, 3-1-1 Asahi, Matsumoto, 390-8621, Japan
| | - Marcel D Nickel
- MR Application Predevelopment, Siemens Healthcare GmbH, Erlangen, Germany
| | - Katsuya Maruyama
- MR Research & Collaboration Department, Siemens Healthcare K. K., Tokyo, Japan
| | - Yasunari Fujinaga
- Department of Radiology, Shinshu University School of Medicine, 3-1-1 Asahi, Matsumoto, 390-8621, Japan.
| |
Collapse
|
30
|
Camera-based respiratory triggering improves the image quality of 3D magnetic resonance cholangiopancreatography. Eur J Radiol 2019; 120:108675. [DOI: 10.1016/j.ejrad.2019.108675] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2019] [Revised: 09/12/2019] [Accepted: 09/17/2019] [Indexed: 11/18/2022]
|
31
|
|
32
|
Lohöfer FK, Kaissis GA, Rasper M, Katemann C, Hock A, Peeters JM, Schlag C, Rummeny EJ, Karampinos D, Braren RF. Magnetic resonance cholangiopancreatography at 3 Tesla: Image quality comparison between 3D compressed sensing and 2D single-shot acquisitions. Eur J Radiol 2019; 115:53-58. [DOI: 10.1016/j.ejrad.2019.04.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2019] [Revised: 03/28/2019] [Accepted: 04/02/2019] [Indexed: 02/06/2023]
|