Nagy E, Tschauner S, Schramek C, Sorantin E. Paediatric CT made easy. Pediatr Radiol 2023; 53:581-588. [PMID: 36333494 PMCID: PMC10027642 DOI: 10.1007/s00247-022-05526-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Revised: 08/28/2022] [Accepted: 10/03/2022] [Indexed: 11/07/2022]
Abstract
Paediatric computed tomography (CT) imaging has always been associated with challenges. Although the technical background of CT imaging is complex, it is worth considering the baseline aspects of radiation exposure to prevent unwanted excess radiation in paediatric patients. In this review, we discuss the most relevant factors influencing radiation exposure, and provide a simplified and practical approach to optimise paediatric CT.
Collapse
Affiliation(s)
- Eszter Nagy
- Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Sebastian Tschauner
- Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Clemens Schramek
- Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria
| | - Erich Sorantin
- Division of Paediatric Radiology, Department of Radiology, Medical University of Graz, Auenbruggerplatz 34, 8036, Graz, Austria.
| |
Collapse
|
2
|
Variation in tube voltage for pediatric neck 64VCT: Effect on radiation dose and image quality. PLoS One 2021; 16:e0259772. [PMID: 34767600 PMCID: PMC8589163 DOI: 10.1371/journal.pone.0259772] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Accepted: 10/27/2021] [Indexed: 11/19/2022] Open
Abstract
Exposure to ionizing radiation can cause cancer, especially in children. In computed tomography (CT), a trade-off exists between the radiation dose and image quality. Few studies have investigated the effect of dose reduction on image quality in pediatric neck CT. We aimed to assess the effect of peak kilovoltage on the radiation dose and image quality in pediatric neck multidetector-row CT. Measurements were made using three phantoms representative of children aged 1, 5, and 10 years, with tube voltages of 80, 100, and 120 kilovoltage peak (kVp); tube current of 10, 40, 80, 120, 150, 200, and 250 mA; and exposure time = 0.5 s (pitch, 0.984:1). Radiation dose estimates were derived from the dose-length product with a 64-multidetector-row CT scanner. Images obtained from the control protocol (120 kVp) were compared with the 80- and 100-kVp protocols. The effective dose (ED) was determined for each protocol and compared with the 120-kVp protocol. Quantitative analysis entailed noise measurements by recording the standard deviation of attenuation for a circular 1-cm2 region of interest placed on homogeneous soft tissue structures in the phantom. The mean noise of the various kVp protocols was compared using the unpaired Student t-test. Reduction of ED was 37.58% and 68.58% for neck CT with 100 kVp and 80 kVp, respectively. The image noise level increased with the decrease in peak kilovoltage. Noise values were higher at 80 kVp at all neck levels, but did not increase at 100 kVp, compared to 120 kVp in the three phantoms. The measured noise difference was the greatest at 80 kVp (absolute increases<2.5 HU). The subjective image quality did not differ among the protocols. Thus, reducing voltage from 120 to 80 kVp for neck CT may achieve ED reduction of 68.58%, without compromising image quality.
Collapse
|
3
|
Papadakis AE, Damilakis J. The effect of tube focal spot size and acquisition mode on task-based image quality performance of a GE revolution HD dual energy CT scanner. Phys Med 2021; 86:75-81. [PMID: 34062336 DOI: 10.1016/j.ejmp.2021.05.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/04/2021] [Revised: 05/05/2021] [Accepted: 05/17/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To assess the task-based performance of images obtained under different focal spot size and acquisition mode on a dual-energy CT scanner. METHODS Axial CT image series of the Catphan phantom were obtained using a tube focus at different sizes. Acquisitions were performed in standard single-energy, high resolution (HR) and dual-energy modes. Images were reconstructed using conventional and high definition (HD) kernels. Task-based transfer function at the 50% level (TTF50%) for teflon, delrin, low density polyethylene (LDPE) and acrylic, as well as image noise and noise texture, were assessed across all focal spots and acquisition modes using Noise Power Spectrum (NPS) analysis. A non-prewhitening mathematical observer model was used to calculate detectability index (dNPW'). RESULTS TTF50% degraded with increasing focal spot size. TTF50% ranged from 0.67 mm-1 for teflon to 0.25 mm-1 for acrylic. For standard kernel, image noise and NPS-determined average spatial frequency were 8.3 HU and 0.29 mm-1, respectively in single-energy, 12.0 HU and 0.37 mm-1 in HR, and 7.9 HU and 0.26 mm-1 in dual-energy mode. For standard kernel, dNPW' was 61 in single-energy and HR mode and reduced to 56 in dual-energy mode. CONCLUSIONS The task-based image quality assessment metrics have shown that spatial resolution is higher for higher image contrast materials and detectability is higher in the standard single-energy mode compared to HR and dual-energy mode. The results of the current study provide CT operators the required knowledge to characterize their CT system towards the optimization of its clinical performance.
Collapse
Affiliation(s)
- Antonios E Papadakis
- Medical Physics Department, University General Hospital of Heraklion, Stavrakia 71110, Crete, Greece.
| | - John Damilakis
- Medical Physics Department, University General Hospital of Heraklion, Stavrakia 71110, Crete, Greece
| |
Collapse
|
4
|
Barca P, Paolicchi F, Aringhieri G, Palmas F, Marfisi D, Fantacci ME, Caramella D, Giannelli M. A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study. PLoS One 2021; 16:e0245374. [PMID: 33444367 PMCID: PMC7808662 DOI: 10.1371/journal.pone.0245374] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Accepted: 12/28/2020] [Indexed: 11/18/2022] Open
Abstract
Nowadays, given the technological advance in CT imaging and increasing heterogeneity in characteristics of CT scanners, a number of CT scanners with different manufacturers/technologies are often installed in a hospital centre and used by various departments. In this phantom study, a comprehensive assessment of image quality of 5 scanners (from 3 manufacturers and with different models) for head CT imaging, as clinically used at a single hospital centre, was hence carried out. Helical and/or sequential acquisitions of the Catphan-504 phantom were performed, using the scanning protocols (CTDIvol range: 54.7–57.5 mGy) employed by the staff of various Radiology/Neuroradiology departments of our institution for routine head examinations. CT image quality for each scanner/acquisition protocol was assessed through noise level, noise power spectrum (NPS), contrast-to-noise ratio (CNR), modulation transfer function (MTF), low contrast detectability (LCD) and non-uniformity index analyses. Noise values ranged from 3.5 HU to 5.7 HU across scanners/acquisition protocols. NPS curves differed in terms of peak position (range: 0.21–0.30 mm-1). A substantial variation of CNR values with scanner/acquisition protocol was observed for different contrast inserts. The coefficient of variation (standard deviation divided by mean value) of CNR values across scanners/acquisition protocols was 18.3%, 31.4%, 34.2%, 30.4% and 30% for teflon, delrin, LDPE, polystyrene and acrylic insert, respectively. An appreciable difference in MTF curves across scanners/acquisition protocols was revealed, with a coefficient of variation of f50%/f10% of MTF curves across scanners/acquisition protocols of 10.1%/7.4%. A relevant difference in LCD performance of different scanners/acquisition protocols was found. The range of contrast threshold for a typical object size of 3 mm was 3.7–5.8 HU. Moreover, appreciable differences in terms of NUI values (range: 4.1%-8.3%) were found. The analysis of several quality indices showed a non-negligible variability in head CT imaging capabilities across different scanners/acquisition protocols. This highlights the importance of a physical in-depth characterization of image quality for each CT scanner as clinically used, in order to optimize CT imaging procedures.
Collapse
Affiliation(s)
- Patrizio Barca
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
| | - Fabio Paolicchi
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | - Giacomo Aringhieri
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | | | - Daniela Marfisi
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
| | | | - Davide Caramella
- Diagnostic and Interventional Radiology, University of Pisa, Pisa, Italy
| | - Marco Giannelli
- Unit of Medical Physics, Pisa University Hospital “Azienda Ospedaliero-Universitaria Pisana”, Pisa, Italy
- * E-mail:
| |
Collapse
|
5
|
Evaluation of an organ-based tube current modulation tool in pediatric CT examinations. Eur Radiol 2020; 30:5728-5737. [PMID: 32435930 PMCID: PMC7476969 DOI: 10.1007/s00330-020-06888-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2019] [Revised: 03/16/2020] [Accepted: 04/10/2020] [Indexed: 11/26/2022]
Abstract
Objectives To investigate the effect of an organ-based tube current modulation (OTCM) technique on organ absorbed dose and assess image quality in pediatric CT examinations. Methods Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old were used. Standard head and thorax acquisitions were performed with automatic tube current modulation (ATCM) and ATCM+OTCM. Dose calculations were performed by means of Monte Carlo simulations. Radiation dose was measured for superficial and centrally located radiosensitive organs. The angular range of the OTCM exposure window was determined for different tube rotation times (t) by means of a solid-state detector. Image noise was measured as the standard deviation of the Hounsfield unit value in regions of interest drawn at selected anatomical sites. Results ATCM+OTCM resulted in a reduction of radiation dose to all radiosensitive organs. In head, eye lens dose was reduced by up to 13% in ATCM+OTCM compared with ATCM. In thorax, the corresponding reduction for breast dose was up to 10%. The angular range of the OTCM exposure window decreased with t. For t = 0.4 s, the angular range was limited to 74° in head and 135° for thorax. Image noise was significantly increased in ATCM+OTCM acquisitions across most examined phantoms (p < 0.05). Conclusions OTCM reduces radiation dose to exposed radiosensitive organs with the eye lens and breast buds exhibiting the highest dose reduction. The OTCM exposure window is narrowed at short t. An increase in noise is inevitable in images located within the OTCM-activated imaged volume. Key Points • In pediatric CT, organ-based tube current modulation reduces radiation dose to all major primarily exposed radiosensitive organs. • Image noise increases within the organ-based tube current modulation enabled imaged volume. • The angular range of the organ-based tube current modulation low exposure window is reduced with tube rotation time.
Collapse
|
6
|
Automatic Tube Current Modulation and Tube Voltage Selection in Pediatric Computed Tomography: A Phantom Study on Radiation Dose and Image Quality. Invest Radiol 2019; 54:265-272. [PMID: 30562273 PMCID: PMC6484681 DOI: 10.1097/rli.0000000000000537] [Citation(s) in RCA: 47] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVES The aim of this study was to investigate the effects of a modern automatic tube current modulation (ATCM) and automatic tube voltage selection (ATVS) system on radiation dose and image quality in pediatric head, and torso computed tomography (CT) examinations for various clinical indications. MATERIALS AND METHODS Four physical anthropomorphic phantoms that represent the average individual as neonate, 1-year-old, 5-year-old, and 10-year-old child were used. Standard head, thorax, and abdomen/pelvis acquisitions were performed with (1) fixed tube current, (2) ATCM, and (3) ATVS. Acquisitions were performed at various radiation dose levels to generate images at different levels of quality. Reference volume CT dose index (CTDIvol), reference image noise, and reference contrast-to-noise ratios were determined. The potential dose reductions with ATCM and ATVS were assessed. RESULTS The percent reduction of CTDIvol with ATCM ranged from 8% to 24% for head, 16% to 39% for thorax, and 25% to 41% for abdomen/pelvis. The percent reduction of CTDIvol with ATVS varied on the clinical indication. In CT angiography, ATVS resulted to the highest dose reduction, which was up to 70% for head, 77% for thorax, and 34% for abdomen/pelvis. In noncontrast examinations, ATVS increased dose by up to 21% for head, whereas reduced dose by up to 34% for thorax and 48% for abdomen/pelvis. CONCLUSIONS In pediatric CT, the use of ATCM significantly reduces radiation dose and maintains image noise. The additional use of ATVS reduces further the radiation dose for thorax and abdomen/pelvis, and maintains contrast-to-noise ratio for the specified clinical diagnostic task.
Collapse
|
7
|
Lin HC, Lai TJ, Tseng HC, Wang CH, Tseng YL, Chen CY. Radiation doses with various body weights of phantoms in brain 128-slice MDCT examination. JOURNAL OF RADIATION RESEARCH 2019; 60:466-475. [PMID: 31197311 PMCID: PMC6640898 DOI: 10.1093/jrr/rrz029] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/07/2019] [Revised: 04/15/2019] [Indexed: 06/09/2023]
Abstract
The effective dose (HE) and organ or tissue equivalent dose (HT) for use in brain computed tomography (CT) examinations with various body weights were evaluated. Thermoluminescent dosimeters (TLD-100H) were inserted into Rando and five anthropomorphic phantoms. These phantoms were made of polymethylmethacrylate (PMMA), according to the specifications of ICRU 48, with masses from 10 to 90 kg. Brain CT examinations were conducted, scanning the maxillae from the external auditory meatus to the parietal bone using a 128-slice multi-detector CT (MDCT) scanner. To reduce errors, three independent trials were conducted. Calculated HE,TLD, based on the weighting factor recommended by ICRP 103, was 1.72 ± 0.28 mSv, which slightly exceeds the HE,DLP of 1.70 mSv, that was calculated from the dose-length product (DLP) of the Rando phantom. This experiment yielded HE,TLD values of ICRP 103 from the highest 1.85 ± 0.28 (90 kg) to the lowest 1.47 ± 0.22 (10 kg) mSv. HE,TLD (mSv) = 5.45×10-3 W(kg) + 1.361, with an R2 of 0.87667. Using the DLP protocol, HE,DLP was estimated from CTDIvol that was recorded directly from the console display of the CT unit and multiplied by the conversion coefficient (k) recommended by the ICRP 103. Finally, the experimental results obtained herein are compared with those in the literature. Physicians should choose and adjust protocols to prevent the exposure of patients to unnecessary radiation, satisfying the as low as reasonably achievable (ALARA) principle. These findings will be valuable to patients, physicians, radiologists and the public.
Collapse
Affiliation(s)
- Hung-Chih Lin
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Te-Jen Lai
- Institute of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Psychiatry, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| | - Hsien-Chun Tseng
- School of Medicine, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Radiation Oncology, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| | - Ching-Hsiang Wang
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Yen-Ling Tseng
- Department of Radiology, Lukang Christian Hospital of Changhua Christian, Medical Foundation, Lukang, Taiwan, Republic of China
| | - Chien-Yi Chen
- Department of Radiation Oncology, Chung Shan Medical University Hospital, Chung Shan Medical University, Taichung, Taiwan, Republic of China
- Department of Medical Imaging and Radiological Sciences, Chung Shan Medical University, Taichung, Taiwan, Republic of China
| |
Collapse
|
8
|
Cai W, Hu C, Hu S, Wang X, Gong J, Zhang W, Shi D, Cheng B. Feasibility study of iterative model reconstruction combined with low tube voltage, low iodine load, and low iodine delivery rate in craniocervical CT angiography. Clin Radiol 2017; 73:217.e1-217.e6. [PMID: 29066028 DOI: 10.1016/j.crad.2017.09.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2017] [Revised: 05/18/2017] [Accepted: 09/20/2017] [Indexed: 12/11/2022]
Abstract
AIM To investigate the feasibility of iterative model reconstruction (IMR) combined with low tube voltage, low iodine load, and low iodine deliver rate in craniocervical computed tomography angiography (CTA). MATERIALS AND METHODS Sixty patients were randomly divided into two groups (n=30 for each): group A: 120 kVp, 50 ml of iopromide at a flow rate of 5 ml/s; filtered back projection (FBP) reconstruction; group B: 80 kVp, 30 ml of iohexol at 4.5 ml/s; hybrid iterative reconstruction (HIR) for group B1 and IMR for group B2. CT attenuation values, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), subjective image quality, effective dose (ED), iodine load, and iodine delivery rate (IDR) were compared. RESULTS CT attenuation values of the arteries were higher in groups B1 and B2 than group A. The SNR and CNR were higher, while image noise was lower, for group B2 compared with groups B1 and A. The best subjective image quality was obtained with group B2. ED, iodine load, and IDR reduction of 69.6%, 51.4%, 27%, respectively, was obtained in group B compared with group A. CONCLUSION IMR combined with 80 kVp and 30 ml of iohexol at a flow rate of 4.5 ml/s for craniocervical CTA can reduce ED, iodine load, and IDR, while improving image quality.
Collapse
Affiliation(s)
- W Cai
- Department of Radiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China; Department of Radiology, Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - C Hu
- Department of Radiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China.
| | - S Hu
- Department of Radiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - X Wang
- Department of Radiology, First Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - J Gong
- Department of Radiology, Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - W Zhang
- Department of Radiology, Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - D Shi
- Department of Radiology, Second Affiliated Hospital of Soochow University, Suzhou, Jiangsu, China
| | - B Cheng
- Department of Radiology, West China Second University Hospital of Sichuan University, Chengdu, Sichuan, China
| |
Collapse
|
9
|
Van Cauteren T, Van Gompel G, Tanaka K, Verdries DE, Belsack D, Nieboer KH, Willekens I, Evans P, Macholl S, Verfaillie G, Droogmans S, de Mey J, Buls N. The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography. BIOMED RESEARCH INTERNATIONAL 2017; 2017:2476171. [PMID: 28620616 PMCID: PMC5460391 DOI: 10.1155/2017/2476171] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 03/16/2017] [Accepted: 03/28/2017] [Indexed: 11/18/2022]
Abstract
OBJECTIVES To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA. METHODS Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann-Whitney U test and Chi-square analysis. RESULTS Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11), except for streak artifacts (p = 0.02) which were considered to be more severe, although acceptable, with the 80 kVp protocol. CONCLUSIONS Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.
Collapse
Affiliation(s)
- Toon Van Cauteren
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Gert Van Gompel
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Kaoru Tanaka
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Douwe E. Verdries
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Dries Belsack
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Koenraad H. Nieboer
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Inneke Willekens
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Paul Evans
- Imaging R&D, GE Healthcare Life Sciences, The Grove Centre, Amersham, Buckinghamshire, UK
| | - Sven Macholl
- Imaging R&D, GE Healthcare Life Sciences, The Grove Centre, Amersham, Buckinghamshire, UK
| | - Guy Verfaillie
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Steven Droogmans
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Johan de Mey
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| | - Nico Buls
- Radiology, Vrije Universiteit Brussel (VUB), Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090 Brussels, Belgium
| |
Collapse
|
10
|
Mesbahi A, Famouri F, Ahar MJ, Ghaffari MO, Ghavami SM. A study on the imaging characteristics of Gold nanoparticles as a contrast agent in X-ray computed tomography. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING 2017. [DOI: 10.1515/pjmpe-2017-0003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Abstract
Aim: In the current study, some imaging characteristics of AuNPs were quantitatively analyzed and compared with two conventional contrast media (CM) including Iodine and Gadolinium by using of a cylindrical phantom.
Methods: AuNPs were synthesized with the mean diameter of 16 nm and were equalized to the concentration of 0.5, 1, 2 and 4 mg/mL in the same volumes. A cylindrical phantom resembling the head and neck was fabricated and drilled to contain small tubes filled with Iodine, Gadolinium, and AuNPs as contrast media. The phantom was scanned in different exposure techniques and CT numbers of three studied contrast media inside test tubes were measured in terms of Hounsfield Unit (HU). The imaging parameters of the noise and contrast to noise ratios (CNR) were calculated for all studied CMs.
Results: AuNPs showed 128% and 166% higher CT number in comparison with Iodine and Gadolinium respectively. Also, Iodine had a greater CT number than Gadolinium for the same exposure techniques and concentration. The maximum CT number for AuNPs and studied contrast materials was obtained at the highest mAs and the lowest tube potential. The maximum CT number were 1033±11 (HU) for AuNP, 565±10 (HU) for Iodine, 458±11 for Gadolinium. Moreover, the maximum CNRs of 433±117, 203±53, 145±37 were found for AuNPs, Iodine and Gadolinium respectively.
Conclusion: The contrast agent based on AuNPs showed higher imaging quality in terms of contrast and noise relative to other iodine and gadolinium based contrast media in X-ray computed tomography. Application of the AuNPs as a contrast medium in x-ray CT is recommended.
Collapse
Affiliation(s)
- Asghar Mesbahi
- Medical Physics Department, Medical School, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
- Medical Radiation Sciences Research Team, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
| | - Fatemeh Famouri
- Medical Physics Department, Medical School, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
| | - Mohammad Johari Ahar
- Department of Medicinal Chemistry, School of Pharmacy, Ardabil University of Medical Sciences, Iran (Islamic Republic of)
| | - Maryam Olade Ghaffari
- Department of Radiology, Shohada Hospital, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
| | - Seyed Mostafa Ghavami
- Department of Radiology, Shohada Hospital, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
- Radiology Department, Paramedical School, Tabriz University of Medical Sciences, Tabriz, Iran (Islamic Republic of)
| |
Collapse
|
11
|
Brix G, Lechel U, Sudarski S, Trumm C, Henzler T. Spectral optimization of iodine-enhanced CT: Quantifying the effect of tube voltage on image quality and radiation exposure determined at an anthropomorphic phantom. Phys Med 2016; 32:999-1006. [PMID: 27484397 DOI: 10.1016/j.ejmp.2016.07.618] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/16/2016] [Revised: 07/14/2016] [Accepted: 07/25/2016] [Indexed: 12/11/2022] Open
Abstract
PURPOSE To provide an experimental basis for spectral optimization of iodine-enhanced CT by a quantitative analysis of image quality and radiation dose characteristics consistently measured for a large variety of scan settings at an anthropomorphic phantom. METHODS CT imaging and thermoluminescent dosimetry were performed at an anthropomorphic whole-body phantom with iodine inserts for different tube voltages (U, 70-140kV) and current-time products (Q, 60-300mAs). For all U-Q combinations, the iodine contrast (C), the noise level (N) and, from these, the contrast-to-noise ratio (CNR) of reconstructed CT images were determined and parameterized as a function of U, Q or the measured absorbed dose (D). Finally, two characteristic curves were derived that give the relative increase of CNR at constant D and the relative decrease of D at constant CNR when lowering U. RESULTS Lowering U affects the measured CNR only slightly but markedly reduces D. For example, reducing U from 120kV to 70kV increases the CNR at constant D by a factor of nearly 1.8 or, alternatively, reduces D at constant CNR by a factor of nearly 5. CONCLUSION Spectral optimization by lowering U is an effective approach to attain the necessary CNR for a specific diagnostic task at hand while at the same time reducing radiation exposure as far as practically achievable. The characteristic curves derived in this study from extensive measurements at a reference 'person' can support CT users in an easy-to-use manner to select an appropriate voltage for various clinical scenarios.
Collapse
Affiliation(s)
- Gunnar Brix
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Oberschleissheim, Germany.
| | - Ursula Lechel
- Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Oberschleissheim, Germany
| | - Sonja Sudarski
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany
| | - Christoph Trumm
- Department of Clinical Radiology, Grosshadern Clinic, Hospital of the Ludwig-Maximilians University, Munich, Germany
| | - Thomas Henzler
- Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Mannheim, Germany
| |
Collapse
|
12
|
Papadakis AE, Perisinakis K, Damilakis J. Development of a method to estimate organ doses for pediatric CT examinations. Med Phys 2016; 43:2108. [DOI: 10.1118/1.4944867] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
|
13
|
Carotid dual-energy CT angiography: Evaluation of low keV calculated monoenergetic datasets by means of a frequency-split approach for noise reduction at low keV levels. Eur J Radiol 2016; 85:720-5. [PMID: 26971414 DOI: 10.1016/j.ejrad.2016.01.015] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2015] [Revised: 01/14/2016] [Accepted: 01/18/2016] [Indexed: 11/23/2022]
Abstract
BACKGROUND AND PURPOSE Calculated monoenergetic ultra-low keV datasets did not lead to improved contrast-to-noise ratio (CNR) due to the dramatic increase in image noise. The aim of the present study was to evaluate the objective image quality of ultra-low keV monoenergetic images (MEIs) calculated from carotid DECT angiography data with a new monoenergetic imaging algorithm using a frequency-split technique. MATERIALS AND METHODS 20 patients (12 male; mean age 53±17 years) were retrospectively analyzed. MEIs from 40 to 120 keV were reconstructed using the monoenergetic split frequency approach (MFSA). Additionally MEIs were reconstructed for 40 and 50 keV using a conventional monoenergetic (CM) software application. Signal intensity, noise, signal-to-noise ratio (SNR) and CNR were assessed in the basilar, common, internal carotid arteries. RESULTS Ultra-low keV MEIs at 40 keV and 50 keV demonstrated highest vessel attenuation, significantly greater than those of the polyenergetic images (PEI) (all p-values <0.05). The highest SNR level and CNR level was found at 40 keV and 50 keV (all p-values <0.05). MEIs with MFSA showed significantly lower noise levels than those processed with CM (all p-values <0.05) and no significant differences in vessel attenuation (p>0.05). Thus MEIs with MFSA showed significantly higher SNR and CNR compared to MEIs with CM. CONCLUSION Combining the lower spatial frequency stack for contrast at low keV levels with the high spatial frequency stack for noise at high keV levels (frequency-split technique) leads to improved image quality of ultra-low keV monoenergetic DECT datasets when compared to previous monoenergetic reconstruction techniques without the frequency-split technique.
Collapse
|
14
|
|
15
|
Magnetic Resonance Imaging and Computed Tomography of the Brain—50 Years of Innovation, With a Focus on the Future. Invest Radiol 2015; 50:551-6. [DOI: 10.1097/rli.0000000000000170] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
16
|
Evaluation of A New Bolus Tracking–Based Algorithm for Predicting A Patient-Specific Time of Arterial Peak Enhancement in Computed Tomography Angiography. Invest Radiol 2015; 50:531-8. [DOI: 10.1097/rli.0000000000000160] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
17
|
Factors influencing real time internal structural visualization and dynamic process monitoring in plants using synchrotron-based phase contrast X-ray imaging. Sci Rep 2015; 5:12119. [PMID: 26183486 PMCID: PMC4648396 DOI: 10.1038/srep12119] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2014] [Accepted: 06/09/2015] [Indexed: 11/08/2022] Open
Abstract
Minimally invasive investigation of plant parts (root, stem, leaves, and flower) has good potential to elucidate the dynamics of plant growth, morphology, physiology, and root-rhizosphere interactions. Laboratory based absorption X-ray imaging and computed tomography (CT) systems are extensively used for in situ feasibility studies of plants grown in natural and artificial soil. These techniques have challenges such as low contrast between soil pore space and roots, long X-ray imaging time, and low spatial resolution. In this study, the use of synchrotron (SR) based phase contrast X-ray imaging (PCI) has been demonstrated as a minimally invasive technique for imaging plants. Above ground plant parts and roots of 10 day old canola and wheat seedlings grown in sandy clay loam soil were successfully scanned and reconstructed. Results confirmed that SR-PCI can deliver good quality images to study dynamic and real time processes such as cavitation and water-refilling in plants. The advantages of SR-PCI, effect of X-ray energy, and effective pixel size to study plant samples have been demonstrated. The use of contrast agents to monitor physiological processes in plants was also investigated and discussed.
Collapse
|
18
|
Quantitative Evaluation of the Performance of a New Test Bolus–Based Computed Tomographic Angiography Contrast-Enhancement–Prediction Algorithm. Invest Radiol 2015; 50:1-8. [DOI: 10.1097/rli.0000000000000088] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
19
|
Buls N, Van Gompel G, Van Cauteren T, Nieboer K, Willekens I, Verfaillie G, Evans P, Macholl S, Newton B, de Mey J. Contrast agent and radiation dose reduction in abdominal CT by a combination of low tube voltage and advanced image reconstruction algorithms. Eur Radiol 2014; 25:1023-31. [PMID: 25432293 PMCID: PMC4356892 DOI: 10.1007/s00330-014-3510-5] [Citation(s) in RCA: 48] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 09/15/2014] [Accepted: 11/14/2014] [Indexed: 01/29/2023]
Abstract
OBJECTIVES To assess image quality in abdominal CT at low tube voltage combined with two types of iterative reconstruction (IR) at four reduced contrast agent dose levels. METHODS Minipigs were scanned with standard 320 mg I/mL contrast concentration at 120 kVp, and with reduced formulations of 120, 170, 220 and 270 mg I/mL at 80 kVp with IR. Image quality was assessed by CT value, dose normalized contrast and signal to noise ratio (CNRD and SNRD) in the arterial and venous phases. Qualitative analysis was included by expert reading. RESULTS Protocols with 170 mg I/mL or higher showed equal or superior CT values: aorta (278-468 HU versus 314 HU); portal vein (205-273 HU versus 208 HU); liver parenchyma (122-146 HU versus 115 HU). In the aorta, all 170 mg I/mL protocols or higher yielded equal or superior CNRD (15.0-28.0 versus 13.7). In liver parenchyma, all study protocols resulted in higher SNRDs. Radiation dose could be reduced from standard CTDIvol = 7.8 mGy (6.2 mSv) to 7.6 mGy (5.2 mSv) with 170 mg I/mL. CONCLUSION Combining 80 kVp with IR allows at least a 47 % contrast agent dose reduction and 16 % radiation dose reduction for images of comparable quality. KEY POINTS • There is a balance between image quality, contrast dose and radiation dose. • Iterative reconstruction has a major, positive impact on this balance. • Both contrast dose and radiation dose can be reduced in abdominal CT. • The trade-off can be quantitatively described by a 3D model. • Contrast and radiation dose can be tailored according to specific safety concerns.
Collapse
Affiliation(s)
- Nico Buls
- Department of Radiology, Universitair Ziekenhuis Brussel (UZ Brussel), Laarbeeklaan 101, 1090, Brussels, Belgium,
| | | | | | | | | | | | | | | | | | | |
Collapse
|
20
|
Assessment of an Advanced Image-Based Technique to Calculate Virtual Monoenergetic Computed Tomographic Images From a Dual-Energy Examination to Improve Contrast-To-Noise Ratio in Examinations Using Iodinated Contrast Media. Invest Radiol 2014; 49:586-92. [PMID: 24710203 DOI: 10.1097/rli.0000000000000060] [Citation(s) in RCA: 245] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
21
|
Papadakis AE, Perisinakis K, Damilakis J. Automatic exposure control in CT: the effect of patient size, anatomical region and prescribed modulation strength on tube current and image quality. Eur Radiol 2014; 24:2520-31. [DOI: 10.1007/s00330-014-3309-4] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2014] [Revised: 04/25/2014] [Accepted: 07/03/2014] [Indexed: 10/25/2022]
|
22
|
Saake M, Lell MM, Rompel O, Gloeckler M, May M, Eller A, Achenbach S, Uder M, Wuest W. Contrast medium application in pediatric high-pitch cardiovascular CT angiography: Manual or power injection? J Cardiovasc Comput Tomogr 2014; 8:315-22. [DOI: 10.1016/j.jcct.2014.05.002] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2014] [Revised: 04/14/2014] [Accepted: 05/08/2014] [Indexed: 11/27/2022]
|