1
|
Ashkar A, Kübler J, Nikolaou K, Hoffmann R, Winkelmann MT. Evaluating Pre-Interventional Administration of a Liver-Specific Contrast Agent During MRI-Guided Thermal Ablation of Malignant Liver Lesions. Cancers (Basel) 2025; 17:1264. [PMID: 40282440 PMCID: PMC12025993 DOI: 10.3390/cancers17081264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2025] [Revised: 04/03/2025] [Accepted: 04/04/2025] [Indexed: 04/29/2025] Open
Abstract
Background/Objectives: Hepatocyte-specific contrast agent (Gd-EOB-DTPA) can improve the detection of liver lesions during MRI-guided thermal ablation. This study aimed to assess the impact of contrast agent administration on the delineation of the ablation zone during therapy monitoring. Methods: From 2010 to 2020, 358 patients with primary and secondary hepatic malignancies underwent MRI-guided thermoablation. A total of 27 patients with 30 liver lesions received Gd-EOB-DTPA during the procedure to improve target lesion visibility (Group 1), while 30 patients with 30 lesions underwent MRI-guided thermoablation without contrast administration (Group 2). T1-weighted volumetric interpolated breath-hold examination (VIBE) sequences were used for intraprocedural imaging, and post-procedural control imaging involved intravenous Gadobutrol administration in both groups. The contrast-to-noise ratio (CNR) was assessed for three key structures: the target lesion before applicator placement, the ablation zone during unenhanced therapy monitoring, and the ablation zone in contrast-enhanced control imaging. A statistical comparison of CNR values between the two groups was performed using the non-parametric Wilcoxon test (p < 0.05). Results: The CNR of lesions in group 1 significantly increased following the administration of Gd-EOB-DTPA. During therapy monitoring, the ablation zone in group 2 exhibited a significantly higher CNR compared to group 1 (median: 7.9 vs. 2.1; p < 0.001). Similarly, at the contrast-enhanced final control, the CNR of the ablation zone remained significantly greater in group 2 than in group 1 (median: 7.7 vs. 2.0; p < 0.001). Conclusions: The administration of a hepatocyte-specific contrast agent (Gd-EOB-DTPA) prior to intervention improves the visualization of liver lesions that are poorly demarcated but significantly reduces the contrast of the ablation zone during intra- and post-procedural imaging. Therefore, its use should be reserved for cases in which the target lesion cannot be sufficiently delineated without contrast.
Collapse
Affiliation(s)
- Antonia Ashkar
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany (K.N.); (R.H.); (M.T.W.)
| | - Jens Kübler
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany (K.N.); (R.H.); (M.T.W.)
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany (K.N.); (R.H.); (M.T.W.)
- Cluster of Excellence iFIT (EXC2180), Eberhard-Karls University, 72076 Tuebingen, Germany
| | - Rüdiger Hoffmann
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany (K.N.); (R.H.); (M.T.W.)
| | - Moritz T. Winkelmann
- Department of Diagnostic and Interventional Radiology, University Hospital of Tuebingen, 72076 Tuebingen, Germany (K.N.); (R.H.); (M.T.W.)
| |
Collapse
|
2
|
Uka M, Matsui Y, Iguchi T, Matsushita T, Tomita K, Umakoshi N, Kawabata T, Yamada M, Hiraki T. Magnetic Resonance Imaging Guidance for Percutaneous Needle Intervention. INTERVENTIONAL RADIOLOGY (HIGASHIMATSUYAMA-SHI (JAPAN) 2024; 9:92-98. [PMID: 39559804 PMCID: PMC11570213 DOI: 10.22575/interventionalradiology.2023-0033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Accepted: 08/16/2023] [Indexed: 11/20/2024]
Abstract
Magnetic resonance imaging (MRI) is one of the guiding modalities used for percutaneous needle insertion during interventional procedures. MRI guidance has several advantages, including multiplanar imaging capability, superior soft tissue contrast resolution, and the absence of ionizing radiation. When performing MRI-guided procedures, it is important to understand the suitable MRI systems, instruments, and imaging sequences for intervention. Furthermore, needle artifact characteristics must be fully understood to ensure safe and accurate needle insertion. In this article, we present the fundamental knowledge as regards the use of MRI guidance for percutaneous needle insertion and review its usefulness in representative interventional procedures, such as biopsy and tumor ablation.
Collapse
Affiliation(s)
- Mayu Uka
- Department of Radiology, Okayama University Hospital, Japan
| | - Yusuke Matsui
- Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Japan
| | - Toshihiro Iguchi
- Department of Radiological Technology, Faculty of Health Sciences, Okayama University, Japan
| | - Toshi Matsushita
- Division of Radiological Technology, Okayama University Hospital, Japan
| | - Koji Tomita
- Department of Radiology, Okayama University Hospital, Japan
| | | | | | | | - Takao Hiraki
- Department of Radiology, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Japan
| |
Collapse
|
3
|
Öcal O, Dietrich O, Lentini S, Bour P, Faller T, Ozenne V, Maier F, Fabritius MP, Puhr-Westerheide D, Schmidt VF, Öcal E, Seidensticker R, Wildgruber M, Ricke J, Seidensticker M. Predicting liver ablation volumes with real-time MRI thermometry. JHEP Rep 2024; 6:101199. [PMID: 39741694 PMCID: PMC11686057 DOI: 10.1016/j.jhepr.2024.101199] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 08/14/2024] [Accepted: 08/21/2024] [Indexed: 01/03/2025] Open
Abstract
Background & Aims MRI guidance offers better lesion targeting for microwave ablation of liver lesions with higher soft-tissue contrast, as well as the possibility of real-time thermometry. This study aims to evaluate the correlation of real-time MR thermometry-predicted lesion volume with the ablation zone in postprocedural first-day images. Methods This single-center retrospective analysis evaluated prospectively included patients who underwent MRI-guided microwave ablation with real-time thermometry between December 2020 and July 2023. All procedures were performed under general anesthesia on a 1.5 T MRI scanner. Real-time thermometry data were acquired using multi-slice gradient-echo echoplanar imaging sequences, and thermal dose maps (CEM43 of 240 min as a threshold) were created. The volume of tissue exposed to a lethal thermal dose in MR thermometry (thermal dose) was compared with the ablation zone volume in portal phase T1w MRI on the postprocedural first day using the Pearson correlation test, and visual quantitative assessment by radiologists was performed to evaluate the similarity of shapes and volumes. Results Out of 30 patients with 33 lesions with thermometry images, six (18.1%) lesions were excluded because of artifacts limiting interpretation of thermal dose volume. Twenty-four patients with 27 lesions (20 male, age 63.1 ± 9.1 years) were evaluated for the volume correlation. The volume of thermal dose-predicted lesions and the postprocedural first-day ablation zones showed a strong correlation (R = 0.89, p <0.001). Similarly, visual similarity of molecular resonance thermometry-predicted shape and the ablation zone shape was graded as perfect in 23 (85.1%) lesions. Conclusions Real-time thermal dose-predicted volumes show very good correlation with the ablation zone volumes in images obtained 1 day after the procedure, which could reduce the local recurrence rates with the possibility of re-ablating lesions within the same procedure. Impact and implications Heat-based ablation is an established treatment for liver tumors; however, there is a considerable rate of incomplete treatment because of the lack of real-time visualization of the treated area during treatment. Our results show that MRI-guided ablation enables the visualization of the treatment area in real-time with high accuracy using a special technique of MR thermometry in patients with liver tumors.
Collapse
Affiliation(s)
- Osman Öcal
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
- Department of Diagnostic and Interventional Radiology, University Hospital Heidelberg, Heidelberg, Germany
| | - Olaf Dietrich
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Sergio Lentini
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | | | | | | | | | | | | | - Vanessa F. Schmidt
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Elif Öcal
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | | | - Moritz Wildgruber
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Jens Ricke
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Max Seidensticker
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| |
Collapse
|
4
|
Winkelmann MT, Kübler J, Hoffmann R. Magnetic Resonance-guided Procedures: Consensus on Rationale, Techniques, and Outcomes. Tech Vasc Interv Radiol 2023; 26:100914. [PMID: 38071023 DOI: 10.1016/j.tvir.2023.100914] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2023]
Abstract
Magnetic resonance (MR) image guidance has demonstrated significant potential in the field of interventional radiology in several applications. This article covers the main points of MR-guided hepatic tumor ablation as a representative of MR-guided procedures. Patient selection and appropriate equipment utilization are essential for successful MR-guided tumor ablation. Intra-procedural planning imaging enables the visualization of the tumor and surrounding anatomical structures in most cases without the application of a contrast agent, ensuring optimal planning of the applicator tract. MRI enables real-time, multiplanar imaging, thus simultaneous observation of the applicator and target tumor is possible during targeting with adaptable slice angulations in case of challenging tumor positions. Typical ablation zone appearance during therapy monitoring with MRI enables safe assessment of the therapy result, resulting in a high primary efficacy rate. Recent advancements in ablation probes have shortened treatment times, while technical strategies address applicator visibility issues. MR-imaging immediately after the procedure is used to rule out complications and to assess technical success. Especially in smaller neoplasms, MRI-guided liver ablation demonstrates positive outcomes in terms of technical success rates, as well as promising survival and recurrence rates. Additionally, percutaneous biopsy under MR guidance offers an alternative to classic guidance modalities, providing high soft tissue contrast and thereby increasing the reliability of lesion detection, particularly in cases involving smaller lesions. Despite these advantages, the use of MR guidance in clinical routine is still limited to few indications and centers, due to by high costs, extended duration, and the need for specialized expertise. In conclusion, MRI-guided interventions could benefit from ongoing advancements in hardware, software, and devices. Such progress has the potential to expand diagnostic and treatment options in the field of interventional radiology.
Collapse
Affiliation(s)
- Moritz T Winkelmann
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany.
| | - Jens Kübler
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| | - Rüdiger Hoffmann
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Tuebingen, Germany
| |
Collapse
|
5
|
Kübler J, Martirosian P, Jacoby J, Gohla G, Winkelmann MT, Nikolaou K, Hoffmann R. Fluid-based augmentation of magnetic resonance visualization of interventional devices. J Appl Clin Med Phys 2021; 22:261-269. [PMID: 34453864 PMCID: PMC8504603 DOI: 10.1002/acm2.13407] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 07/13/2021] [Accepted: 08/14/2021] [Indexed: 01/19/2023] Open
Abstract
PURPOSE To evaluate the transient artifact augmentation of microtubes in magnetic resonance imaging by fluid injection. METHODS Twenty-one fluorinated ethylene propylene catheters (inner diameter 760 μm) were filled with three different contrast media at various concentrations (Ferucarbotran, Resovist®, Bayer Schering Pharma; Manganese dichloride, MnCl2, Sigma-Aldrich; Gadobutrol, Gadovist®, Bayer Schering Pharma). Artifact appearance was determined in an ex vivo phantom at 1.5 T using three different sequences: T1-weighted three-dimensional volume interpolated breath-hold examination, T2-weighted turbo spin echo, and T1-weighted fast low angle shot. Catheter angulation to the main magnetic field (B0) was varied. Influence of parameters on artifact diameters was assessed with a multiple linear regression similar to an analysis of variance. RESULTS Artifact diameter was significantly influenced by the contrast agent (p < 0.001), concentration of the contrast agent (p < 0.001), angulation of the phantom to B0 with the largest artifact at 90° (p < 0.001), and encoding direction with a larger diameter in phase encoding direction (PED, p < 0.001). Mean artifact diameters at 90° angulation to B0 in PED were 18.5 ± 5.4 mm in 0.5 mmol/ml Ferucarbotran, 8.7 ± 2.5 mm in 1 mmol/ml Gadobutrol, and 11.6 ± 4.6 mm in 5 mmol/ml MnCl2 . CONCLUSIONS Fluid-based contrast agents might be applied to interventional devices and thus temporarily augment the artifact ensuring both visibility and safe navigation.
Collapse
Affiliation(s)
- Jens Kübler
- Department of Diagnostic and Interventional RadiologyUniversity Hospital of TübingenTübingenGermany
| | - Petros Martirosian
- Section on Experimental RadiologyUniversity Hospital of TübingenTübingenGermany
| | - Johann Jacoby
- Institute of Clinical Epidemiology and Applied BiometryUniversity Hospital of TübingenTübingenGermany
| | - Georg Gohla
- Department of Diagnostic and Interventional RadiologyUniversity Hospital of TübingenTübingenGermany
| | - Moritz T. Winkelmann
- Department of Diagnostic and Interventional RadiologyUniversity Hospital of TübingenTübingenGermany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional RadiologyUniversity Hospital of TübingenTübingenGermany
| | - Rüdiger Hoffmann
- Department of Diagnostic and Interventional RadiologyUniversity Hospital of TübingenTübingenGermany
| |
Collapse
|
6
|
Gohla G, Archid R, Hoffmann R, Kübler J, Munzel M, Königsrainer A, Nadalin S, Nikolaou K, Winkelmann MT. MRI-guided percutaneous thermoablation as first-line treatment of recurrent hepatic malignancies following hepatic resection: single center long-term experience. Int J Hyperthermia 2021; 38:1401-1408. [PMID: 34542009 DOI: 10.1080/02656736.2021.1979257] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022] Open
Abstract
PURPOSE Hepatic recurrence of liver malignancies is a leading problem in patients after liver resection with curative intention. Thermoablation is a promising treatment approach for patients after hepatic resection, especially in liver-limited conditions. This study aimed to investigate safety, survival, and local tumor control rates of MRI-guided percutaneous thermoablation of recurrent hepatic malignancies following hepatic resection. MATERIAL AND METHODS Data from patients with primary or secondary hepatic malignancies treated between 2004 and 2018 with MRI-guided percutaneous thermoablation of hepatic recurrence after prior hepatic resection were retrospectively analyzed. Disease-free survival and overall survival rates were calculated using the Kaplan-Meier method. RESULTS A total of 57 patients with hepatic recurrence (mean tumor size = 18.9 ± 9.1 mm) of colorectal cancer liver metastases (n = 27), hepatocellular carcinoma (n = 17), intrahepatic recurrence of cholangiocellular carcinoma (n = 9), or other primary malignant tumor entities (n = 4) were treated once or several times with MR-guided percutaneous radiofrequency (n = 52) or microwave ablation (n = 5) (range: 1-4 times). Disease progression occurred due to local recurrence at the ablation site in nine patients (15.8%), non-local hepatic recurrence in 33 patients (57.9%), and distant malignancy in 18 patients (31.6%). The median overall survival for the total cohort was 40 months and 49 months for the colorectal cancer group, with a 5-year overall survival rate of 40.7 and 42.5%, respectively. The median disease-free survival was 10 months for both the total cohort and the colorectal cancer group with a 5-year disease-free survival rate of 15.1 and 14.8%, respectively. The mean follow-up time was 39.6 ± 35.7 months. CONCLUSION MR-guided thermoablation is an effective and safe approach in the treatment of hepatic recurrences in liver-limited conditions and can achieve long-term survival.
Collapse
Affiliation(s)
- G Gohla
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| | - R Archid
- Department of General, Visceral and Transplant Surgery, University Hospital Tübingen, Tübingen, Germany
| | - R Hoffmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| | - J Kübler
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| | - M Munzel
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| | - A Königsrainer
- Department of General, Visceral and Transplant Surgery, University Hospital Tübingen, Tübingen, Germany
| | - S Nadalin
- Department of General, Visceral and Transplant Surgery, University Hospital Tübingen, Tübingen, Germany
| | - K Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| | - M T Winkelmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Tübingen, Germany
| |
Collapse
|
7
|
Subregion Radiomics Analysis to Display Necrosis After Hepatic Microwave Ablation-A Proof of Concept Study. Invest Radiol 2021; 55:422-429. [PMID: 32028297 DOI: 10.1097/rli.0000000000000653] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
OBJECTIVES The aim of this study was to improve the visualization of coagulation necrosis after computed tomography (CT)-guided microwave ablation (MWA) in routine postablational imaging. MATERIALS AND METHODS Ten MWAs were performed in 8 pigs under CT guidance. After each ablation, we obtained contrast-enhanced CT scans in venous phase. Ablations were then resected as a whole, and histologic slices were obtained orthogonally through the ablation center. Subsequently, a vital stain was applied to the sections for visualization of coagulation necrosis. Computed tomography images were reformatted to match the histologic slices. Afterwards, quantitative imaging features were extracted from the subregions of all images, and binary classifiers were used to predict the presence of coagulation necrosis for each subregion. From this, heatmaps could be created, which visually represented the extent of necrosis in each CT image. Two independent observers evaluated the extent of coagulative necrosis between the heat maps and histological sections. RESULTS We applied 4 different classifiers, including a generalized linear mixed model (GLMM), a stochastic gradient boosting classifier, a random forest classifier, and a k-nearest neighbor classifier, out of which the GLMM showed the best performance to display coagulation necrosis. The GLMM resulted in an area under the curve of 0.84 and a Jaccard index of 0.6 between the generated heat map and the histologic reference standard as well as a good interobserver agreement with a Jaccard index of 0.9. CONCLUSIONS Subregion radiomics analysis may improve visualization of coagulation necrosis after hepatic MWA in an in vivo porcine model.
Collapse
|
8
|
Huang W, Lu J, Tang R, Wu Z, Wang Q, Ding X, Wang Z, Chen K. Phase Contrast Imaging Based Microbubble Monitoring of Radiofrequency Ablation: An ex vivo Study. Front Oncol 2020; 10:1709. [PMID: 32984051 PMCID: PMC7477093 DOI: 10.3389/fonc.2020.01709] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/25/2019] [Accepted: 07/30/2020] [Indexed: 01/15/2023] Open
Abstract
Background To explore the potential of synchrotron radiation (SR) phase contrast imaging (PCI) for real-time microbubble formation monitoring during radiofrequency ablation (RFA). Methods RFA was performed on ex vivo porcine muscle tissue using unipolar and multi-tined expandable electrodes. Images of microbubble formation in the samples were captured by both SR PCI and absorption contrast imaging. The synchronous ablation temperature was recorded. Each RFA electrode type group contained 6 samples. Ablation size was assessed by histologic examination. Results Microbubble formation during RFA could be visualized by SR PCI. The diameter of the microbubbles revealed on the image ranged from tens of microns to several millimeters, and these microbubbles first appeared at the edge of the RFA electrode when the target region temperature reached approximately 60°C and rapidly extended outwards. The average microbubble range measured on PCI was 17.66 ± 0.74 mm. The average range of coagulation necrosis measured by histological examination was 17.22 ± 0.38 mm. There was no significant difference between them (P > 0.05). The range of microbubbles corresponded to the ablation zone. Conclusion PCI enabled real-time high-resolution visualization of microbubble formation during RFA, indicating a potential for its use in ablation monitoring.
Collapse
Affiliation(s)
- Wei Huang
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Jian Lu
- Department of Radiology, Ruijin Hospital/Luwan Branch, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Rongbiao Tang
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Zhiyuan Wu
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Qingbing Wang
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Xiaoyi Ding
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Zhongmin Wang
- Department of Radiology, Ruijin Hospital/Luwan Branch, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| | - Kemin Chen
- Department of Radiology, Ruijin Hospital, School of Medicine, Shanghai Jiaotong University, Shanghai, China
| |
Collapse
|
9
|
Winkelmann MT, Gohla G, Kübler J, Weiß J, Clasen S, Nikolaou K, Hoffmann R. MR-Guided High-Power Microwave Ablation in Hepatic Malignancies: Initial Results in Clinical Routine. Cardiovasc Intervent Radiol 2020; 43:1631-1638. [PMID: 32699978 PMCID: PMC7591402 DOI: 10.1007/s00270-020-02584-5] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2020] [Accepted: 06/26/2020] [Indexed: 12/15/2022]
Abstract
PURPOSE Evaluation of technique effectiveness, patient safety and ablation parameters of MR-guided microwave ablation in hepatic malignancies using an MR-conditional high-power microwave ablation system. MATERIALS AND METHODS Institutional review board approval and informed patient consent were obtained. Patients who underwent MR-guided microwave ablation of hepatic malignancies in a 1.5T wide-bore scanner using a perfusion-cooled high-power microwave ablation system with a maximum generator power of 150 W were included. Ablation parameters comprising procedure durations, net ablation duration, applicator positions and ablation zone dimensions were recorded. Adverse events were classified according to the CIRSE classification system. Technique effectiveness was assessed after 1 month. Follow-up was conducted with contrast-enhanced MRI and ranged from 1 to 20 months (mean: 6.1 ± 5.4 months). RESULTS Twenty-one consecutive patients (age: 63.4 ± 10.5 years; 5 female) underwent 22 procedures for 28 tumours (9 hepatocellular carcinomas, 19 metastases) with a mean tumour diameter of 14.6 ± 5.4 mm (range: 6-24 mm). Technique effectiveness was achieved in all lesions. Tumours were treated using 1.7 ± 0.7 applicator positions (range: 1-3). Mean energy and ablation duration per tumour were 75.3 ± 35.4 kJ and 13.3 ± 6.2 min, respectively. Coagulation zone short- and long-axis diameters were 29.1 ± 6.4 mm and 39.9 ± 7.4 mm, respectively. Average procedure duration was 146.4 ± 26.2 min (range: 98-187 min). One minor complication was reported. Five patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed during initial follow-up. CONCLUSION MR-guided high-power microwave ablation provides safe and effective treatment of hepatic malignancies with short ablation times and within acceptable procedure durations.
Collapse
Affiliation(s)
- Moritz T Winkelmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Georg Gohla
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Jens Kübler
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Jakob Weiß
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Stephan Clasen
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Rüdiger Hoffmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany.
| |
Collapse
|
10
|
Winkelmann MT, Archid R, Gohla G, Hefferman G, Kübler J, Weiss J, Clasen S, Nikolaou K, Nadalin S, Hoffmann R. MRI-guided percutaneous thermoablation in combination with hepatic resection as parenchyma-sparing approach in patients with primary and secondary hepatic malignancies: single center long-term experience. Cancer Imaging 2020; 20:37. [PMID: 32460898 PMCID: PMC7251813 DOI: 10.1186/s40644-020-00316-z] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 05/18/2020] [Indexed: 12/17/2022] Open
Abstract
BACKGROUND Combination therapy using hepatic resection (HR) and intra-operative thermal ablation is a treatment approach for patients with technically unresectable liver malignancies. The aim of this study was to investigate safety, survival and local recurrence rates for patients with technically unresectable liver tumors undergoing HR and separate percutaneous MR-guided thermoablation procedure as an alternative approach. METHODS Data from all patients with primary or secondary hepatic malignancies treated at a single institution between 2004 and 2018 with combined HR and MR-guided percutaneous thermoablation was collected and retrospectively analyzed. Complications, procedure related information and patient characteristics were collected from institutional records. Overall survival and disease-free survival were estimated using the Kaplan-Meier method. RESULTS A total of 31 patients (age: 62.8 ± 9.1 years; 10 female) with hepatocellular carcinoma (HCC; n = 7) or hepatic metastases (n = 24) were treated for 98 hepatic tumors. Fifty-six tumors (mean diameter 28.7 ± 23.0 mm) were resected. Forty-two tumors (15.1 ± 7.6 mm) were treated with MR-guided percutaneous ablation with a technical success rate of 100%. Local recurrence at the ablation site occurred in 7 cases (22.6%); none of these was an isolated local recurrence. Six of 17 patients (35.3%) treated for colorectal liver metastases developed local recurrence. Five patients developed recurrence at the resection site (16.1%). Non-local hepatic recurrence was observed in 18 cases (58.1%) and extrahepatic recurrence in 11 cases (35.5%) during follow-up (43.1 ± 26.4 months). Ten patients (32.3%) developed complications after HR requiring pharmacological or interventional treatment. No complication requiring therapy was observed after ablation. Median survival time was 44.0 ± 7.5 months with 1-,3-, 5-year overall survival rates of 93.5, 68.7 and 31.9%, respectively. The 1-, 3- and 5-year disease-free survival rates were 38.7, 19.4 and 9.7%, respectively. CONCLUSION The combination of HR and MR-guided thermoablation is a safe and effective approach in the treatment of technically unresectable hepatic tumors and can achieve long-term survival.
Collapse
Affiliation(s)
- Moritz T Winkelmann
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.
| | - Rami Archid
- Department of General, Visceral and Transplant Surgery, University Hospital Tuebingen, Tübingen, Germany
| | - Georg Gohla
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| | - Gerald Hefferman
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany.,Harvard Medical School, Harvard University, Boston, MA, USA
| | - Jens Kübler
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| | - Jakob Weiss
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| | - Stephan Clasen
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| | - Konstantin Nikolaou
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| | - Silvio Nadalin
- Department of General, Visceral and Transplant Surgery, University Hospital Tuebingen, Tübingen, Germany
| | - Rüdiger Hoffmann
- Department for Diagnostic and Interventional Radiology, University Hospital Tuebingen, Hoppe-Seyler-Straße 3, 72076, Tübingen, Germany
| |
Collapse
|
11
|
Bressem KK, Vahldiek JL, Erxleben C, Shnayien S, Poch F, Geyer B, Lehmann KS, Hamm B, Niehues SM. Improved Visualization of the Necrotic Zone after Microwave Ablation Using Computed Tomography Volume Perfusion in an In Vivo Porcine Model. Sci Rep 2019; 9:18506. [PMID: 31811190 PMCID: PMC6898643 DOI: 10.1038/s41598-019-55026-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Accepted: 11/21/2019] [Indexed: 01/02/2023] Open
Abstract
After hepatic microwave ablation, the differentiation between fully necrotic and persistent vital tissue through contrast enhanced CT remains a clinical challenge. Therefore, there is a need to evaluate new imaging modalities, such as CT perfusion (CTP) to improve the visualization of coagulation necrosis. MWA and CTP were prospectively performed in five healthy pigs. After the procedure, the pigs were euthanized, and the livers explanted. Orthogonal histological slices of the ablations were stained with a vital stain, digitalized and the necrotic core was segmented. CTP maps were calculated using a dual-input deconvolution algorithm. The segmented necrotic zones were overlaid on the DICOM images to calculate the accuracy of depiction by CECT/CTP compared to the histological reference standard. A receiver operating characteristic analysis was performed to determine the agreement/true positive rate and disagreement/false discovery rate between CECT/CTP and histology. Standard CECT showed a true positive rate of 81% and a false discovery rate of 52% for display of the coagulation necrosis. Using CTP, delineation of the coagulation necrosis could be improved significantly through the display of hepatic blood volume and hepatic arterial blood flow (p < 0.001). The ratios of true positive rate/false discovery rate were 89%/25% and 90%/50% respectively. Other parameter maps showed an inferior performance compared to CECT.
Collapse
Affiliation(s)
- Keno K Bressem
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany.
| | - Janis L Vahldiek
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Christoph Erxleben
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Seyd Shnayien
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Franz Poch
- Department of Surgery, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Beatrice Geyer
- Department of Surgery, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Kai S Lehmann
- Department of Surgery, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - B Hamm
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| | - Stefan M Niehues
- Department of Radiology, Charité, Hindenburgdamm 30, 12203, Berlin, Germany
| |
Collapse
|
12
|
Liu Y, Guan Q, Kong X, De Keyzer F, Feng Y, Chen F, Yu J, Liu J, Song S, van Pelt J, Swinnen J, Bormans G, Oyen R, Wang S, Huang G, Ni Y, Li Y. Predicting Therapeutic Efficacy of Vascular Disrupting Agent CA4P in Rats with Liver Tumors by Hepatobiliary Contrast Agent Mn-DPDP-Enhanced MRI. Transl Oncol 2019; 13:92-101. [PMID: 31810003 PMCID: PMC6909075 DOI: 10.1016/j.tranon.2019.09.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2019] [Revised: 09/16/2019] [Accepted: 09/16/2019] [Indexed: 02/07/2023] Open
Abstract
To evaluate hepatobiliary-specific contrast agent (CA) mangafodipir trisodium (Mn-DPDP)–enhanced magnetic resonance imaging (MRI) for predicting the therapeutic efficacy of the vascular disrupting agent combretastatin A4 phosphate (CA4P) in rats with primary and secondary liver tumors, 36 primary hepatocellular carcinomas (HCCs) were raised by diethylnitrosamine gavage in 16 male rats, in 6 of which one rhabdomyosarcomas (R1) was intrahepatically implanted as secondary liver tumors. On a 3.0T MR scanner with a wrist coil, tumors were monitored weekly by T2-/T1-weighted images (T2WI/T1WI) and characterized by Mn-DPDP-enhanced MRI. CA4P-induced intratumoral necrosis was depicted by nonspecific gadoterate meglumine (Gd-DOTA)–enhanced MRI before and 12 h after therapy. Changes of tumor-to-liver contrast (ΔT/L) on Mn-DPDP-enhanced images were analyzed. In vivo MRI findings were verified by postmortem microangiography and histopathology. Rat models of primary HCCs in a full spectrum of differentiation and secondary R1 liver tumors were successfully generated. Mn-DPDP-enhanced ΔT/L was negatively correlated with HCC differentiation grade (P < 0.01). After treatment with CA4P, more extensive tumoral necrosis was found in highly differentiated HCCs than that in moderately and poorly differentiated ones (P < 0.01); nearly complete necrosis was induced in secondary liver tumors. Mn-DPDP-enhanced MRI may help in imaging diagnosis of primary and secondary liver malignancies of different cellular differentiations and further in predicting CA4P therapeutic efficacy in primary HCCs and intrahepatic metastases.
Collapse
Affiliation(s)
- Yewei Liu
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium; Institute of Clinical Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China; Institute of Health Sciences, Shanghai Jiao Tong University School of Medicine (SJTUSM) & Shanghai Institutes for Biological Sciences (SIBS), Chinese Academy of Sciences (CAS), Shanghai 200025, China
| | - Qiu Guan
- College of Computer Science, Zhejiang University of Technology, Hangzhou 310027, China
| | - Xiangyong Kong
- College of Computer Science, Zhejiang University of Technology, Hangzhou 310027, China
| | | | - Yuanbo Feng
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Feng Chen
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Jie Yu
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Jianjun Liu
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Institute of Clinical Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China
| | - Shaoli Song
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Department of Nuclear Medicine, Fudan University Shanghai Cancer Center, Shanghai 200032, China
| | - Jos van Pelt
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Johan Swinnen
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Guy Bormans
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Raymond Oyen
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Shuncong Wang
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium
| | - Gang Huang
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Institute of Clinical Nuclear Medicine, Renji Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai 200127, China; Institute of Health Sciences, Shanghai Jiao Tong University School of Medicine (SJTUSM) & Shanghai Institutes for Biological Sciences (SIBS), Chinese Academy of Sciences (CAS), Shanghai 200025, China.
| | - Yicheng Ni
- Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium.
| | - Yue Li
- Shanghai Key Laboratory of Molecular Imaging, Shanghai University of Medicine and Health Sciences, Shanghai 201318, China; Biomedical Group, Campus Gasthuisberg, KU Leuven, Leuven 3000, Belgium.
| |
Collapse
|
13
|
MRI-Guided Cryoablation of Hepatic Dome Hepatocellular Carcinomas Using 1-T Open High-Field-Strength Scanner. AJR Am J Roentgenol 2019; 212:1361-1369. [PMID: 30860902 DOI: 10.2214/ajr.18.19815] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
OBJECTIVE. The objective of our study was to prospectively evaluate the feasibility, safety, and effectiveness of 1-T open MRI-guided percutaneous cryoablation of hepatic dome hepatocellular carcinomas (HCCs). SUBJECTS AND METHODS. Thirty-seven patients with 37 hepatic dome HCCs underwent MRI-guided percutaneous cryoablations. MR fluoroscopy with a freehand technique was applied in the procedure. All lesions ranged in size from 8 to 38 mm. Patients were followed for at least 12 months after cryoablation or until death. Survival period, local tumor control, and complications were recorded. RESULTS. MRI-guided percutaneous cryoablation procedures were successfully performed on all 37 lesions. The technical success rate was 100%. The median follow-up time was 21.0 months (range, 10-26 months). Two patients with local tumor progression at the 4th and 11th month after the procedure were treated with a supplementary cryoablation. One patient died of upper gastrointestinal hemorrhage at the 10th month after cryoablation. Local tumor progression and overall survival rates were 2.7% (1/37) and 100% (37/37) at 6 months and 5.4% (2/37) and 97.3% (36/37) at 1 year, respectively. Postoperative hydrothorax that required chest tube drainage occurred in two patients; no other severe complications occurred. CONCLUSION. Cryoablation of hepatic dome HCCs with 1-T open MRI guidance is a feasible, safe, and effective therapy method.
Collapse
|
14
|
He X, Liu M, Liu C, Fang J, Xu Y, Wang L, Xiang J, Sequeiros RB, Li C. Real-time MR-guided brain biopsy using 1.0-T open MRI scanner. Eur Radiol 2018; 29:85-92. [PMID: 29948073 DOI: 10.1007/s00330-018-5531-y] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2018] [Revised: 04/24/2018] [Accepted: 05/07/2018] [Indexed: 10/14/2022]
Abstract
OBJECTIVES To evaluate the safety, feasibility and diagnostic performance of real-time MR-guided brain biopsy using a 1.0-T open MRI scanner. METHODS Medical records of 86 consecutive participants who underwent brain biopsy under the guidance of a 1.0-T open MRI scanner with real-time and MR fluoroscopy techniques were evaluated retrospectively. All procedures were performed under local anaesthesia and intravenous conscious sedation. Diagnostic yield, diagnostic accuracy, complication rate and procedure duration were assessed. The lesions were divided into two groups according to maximum diameters: ≤ 1.5 cm (n = 16) and > 1.5 cm (n = 70). The two groups were compared using Fisher's exact test. RESULTS Diagnostic yield and diagnostic accuracy were 95.3% and 94.2%, respectively. The diagnostic yield of lesions ≤ 1.5 cm and > 1.5 cm were 93.8% and 95.7%, respectively. There was no significant difference in diagnostic yield between the two groups (p > 0.05). Mean procedure duration was 41 ± 5 min (range 33-49 min). All biopsy needles were placed with one pass. Complication rate was 3.5% (3/86). Minor complications included three cases of a small amount of haemorrhage. No serious complications were observed. CONCLUSIONS Real-time MR-guided brain biopsy using a 1.0-T open MRI scanner is a safe, feasible and accurate diagnostic technique for pathological diagnosis of brain lesions. The procedure duration is shortened and biopsy work flow is simplified. It could be considered as an alternative for brain biopsy. KEY POINTS • Real-time MRI-guided brain biopsy using a 1.0-T open MRI scanner is safe, feasible and accurate. • No serious complications occurred in real-time MRI-guided brain biopsy. • Procedure duration is shortened and biopsy work flow is simplified.
Collapse
Affiliation(s)
- Xiangmeng He
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Ming Liu
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Chao Liu
- Department of Minimally Invasive Tumor, Tai'an Central Hospital, Tai'an, Shandong, People's Republic of China
| | - Jing Fang
- Department of Hemodialysis, The Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, Shandong, People's Republic of China
| | - Yujun Xu
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Ligang Wang
- Department of Medical Imaging and Interventional Radiology, Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, Shandong, People's Republic of China
| | - Jianfeng Xiang
- Department of Intervention, Shanghai Jiaotong University Affiliated Sixth People's Hospital South Campus, Shanghai, People's Republic of China
| | | | - Chengli Li
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China.
| |
Collapse
|
15
|
Affiliation(s)
- Jakob Weiss
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | | | | |
Collapse
|
16
|
Korkusuz Y, Gröner D, Raczynski N, Relin O, Kingeter Y, Grünwald F, Happel C. Thermal ablation of thyroid nodules: are radiofrequency ablation, microwave ablation and high intensity focused ultrasound equally safe and effective methods? Eur Radiol 2017; 28:929-935. [PMID: 28894936 DOI: 10.1007/s00330-017-5039-x] [Citation(s) in RCA: 78] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2016] [Revised: 06/06/2017] [Accepted: 08/16/2017] [Indexed: 12/18/2022]
Abstract
OBJECTIVES This study compares volume reduction of benign thyroid nodules three months after Radiofrequency Ablation (RFA), Microwave Ablation (MWA) or High Intensity Focused Ultrasound (HIFU) to evaluate which of these methods is the most effective and safe alternative to thyroidectomy or radioiodine therapy. MATERIAL AND METHODS Ninety-four patients (39 male, 55 female) with a total of 118 benign, symptomatic thyroid nodules were divided into three subgroups. HIFU was applied to 14 patients with small nodules. The other 80 patients were divided up into two groups of 40 patients each for RFA and MWA in the assumption that both methods are comparable effective. The pre-ablative and post-ablative volume was measured by ultrasound. RESULTS RFA showed a significant volume reduction of nodules of 50 % (p<0.05), MWA of 44 % (p<0.05) and HIFU of 48 % (p<0.05) three months after ablation. None of the examined ablation techniques caused serious or permanent complications. CONCLUSION RFA, MWA and HIFU showed comparable results considering volume reduction. All methods are safe and effective treatments of benign thyroid nodules. KEY POINTS • Thermal Ablation can be used to treat benign thyroid nodules • Thermal Ablation can be an alternative to thyroidectomy or radioiodine therapy • Radiofrequency Ablation, Microwave Ablation, High Intensity Focused Ultrasound are safe and effective.
Collapse
Affiliation(s)
- Yücel Korkusuz
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany.,German Centre for Thermoablation of Thyroid Nodules, University Hospital Frankfurt, Frankfurt, Germany
| | - Daniel Gröner
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany.,German Centre for Thermoablation of Thyroid Nodules, University Hospital Frankfurt, Frankfurt, Germany
| | - Natascha Raczynski
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany.
| | - Oleg Relin
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany
| | - Yasmina Kingeter
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany
| | - Frank Grünwald
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany.,German Centre for Thermoablation of Thyroid Nodules, University Hospital Frankfurt, Frankfurt, Germany
| | - Christian Happel
- Department of Nuclear Medicine, University Hospital Frankfurt, Theodor-Stern-Kai 7, D-60590, Frankfurt/Main, Germany.,German Centre for Thermoablation of Thyroid Nodules, University Hospital Frankfurt, Frankfurt, Germany
| |
Collapse
|
17
|
Hoffmann R, Kessler DE, Weiss J, Clasen S, Pereira PL, Nikolaou K, Rempp H. Preclinical evaluation of an MR-compatible microwave ablation system and comparison with a standard microwave ablation system in an ex vivo bovine liver model. Int J Hyperthermia 2017; 33:617-623. [DOI: 10.1080/02656736.2017.1284349] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Affiliation(s)
- Rüdiger Hoffmann
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - David-Emanuel Kessler
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Jakob Weiss
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Stephan Clasen
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Philippe L. Pereira
- Department of Radiology, Minimally Invasive Therapies and Nuclear Medicine, SLK-Kliniken Heilbronn GmbH, Heilbronn, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| | - Hansjörg Rempp
- Department of Diagnostic and Interventional Radiology, Eberhard Karls University Tuebingen, Tuebingen, Germany
| |
Collapse
|
18
|
Wybranski C, Pech M, Lux A, Ricke J, Fischbach F, Fischbach K. Hybrid Approach for Biliary Interventions Employing MRI-Guided Bile Duct Puncture with Near-Real-Time Imaging. Cardiovasc Intervent Radiol 2017; 40:884-893. [PMID: 28160096 DOI: 10.1007/s00270-017-1591-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/24/2016] [Accepted: 01/25/2017] [Indexed: 10/20/2022]
Abstract
OBJECTIVE To assess the feasibility of a hybrid approach employing MRI-guided bile duct (BD) puncture for subsequent fluoroscopy-guided biliary interventions in patients with non-dilated (≤3 mm) or dilated BD (≥3 mm) but unfavorable conditions for ultrasonography (US)-guided BD puncture. METHODS A total of 23 hybrid interventions were performed in 21 patients. Visualization of BD and puncture needles (PN) in the interventional MR images was rated on a 5-point Likert scale by two radiologists. Technical success, planning time, BD puncture time and positioning adjustments of the PN as well as technical success of the biliary intervention and complication rate were recorded. RESULTS Visualization even of third-order non-dilated BD and PN was rated excellent by both radiologists with good to excellent interrater agreement. MRI-guided BD puncture was successful in all cases. Planning and BD puncture times were 1:36 ± 2.13 (0:16-11:07) min. and 3:58 ± 2:35 (1:11-9:32) min. Positioning adjustments of the PN was necessary in two patients. Repeated capsular puncture was not necessary in any case. All biliary interventions were completed successfully without major complications. CONCLUSION A hybrid approach which employs MRI-guided BD puncture for subsequent fluoroscopy-guided biliary intervention is feasible in clinical routine and yields high technical success in patients with non-dilated BD and/or unfavorable conditions for US-guided puncture. Excellent visualization of BD and PN in near-real-time interventional MRI allows successful cannulation of the BD.
Collapse
Affiliation(s)
- Christian Wybranski
- Department of Diagnostic and Interventional Radiology, University Hospital of Cologne, Kerpener Str. 62, 50937, Cologne, Germany.
| | - Maciej Pech
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Medical School, Magdeburg, Germany
| | - Anke Lux
- Institute of Biometry and Medical Informatics, Otto-von-Guericke University Medical School, Magdeburg, Germany
| | - Jens Ricke
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Medical School, Magdeburg, Germany
| | - Frank Fischbach
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Medical School, Magdeburg, Germany
| | - Katharina Fischbach
- Department of Radiology and Nuclear Medicine, Otto-von-Guericke University Medical School, Magdeburg, Germany
| |
Collapse
|
19
|
Hoffmann R, Rempp H, Keßler DE, Weiß J, Pereira PL, Nikolaou K, Clasen S. MR-guided microwave ablation in hepatic tumours: initial results in clinical routine. Eur Radiol 2016; 27:1467-1476. [PMID: 27553935 DOI: 10.1007/s00330-016-4517-x] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 05/11/2016] [Accepted: 07/19/2016] [Indexed: 02/06/2023]
Abstract
OBJECTIVES Evaluation of the technical success, patient safety and technical effectiveness of magnetic resonance (MR)-guided microwave ablation of hepatic malignancies. METHODS Institutional review board approval and informed patient consent were obtained. Fifteen patients (59.8 years ± 9.5) with 18 hepatic malignancies (7 hepatocellular carcinomas, 11 metastases) underwent MR-guided microwave ablation using a 1.5-T MR system. Mean tumour size was 15.4 mm ± 7.7 (7-37 mm). Technical success and ablation zone diameters were assessed by post-ablative MR imaging. Technique effectiveness was assessed after 1 month. Complications were classified according to the Common Terminology Criteria for Adverse Events (CTCAE). Mean follow-up was 5.8 months ± 2.6 (1-10 months). RESULTS Technical success and technique effectiveness were achieved in all lesions. Lesions were treated using 2.5 ± 1.2 applicator positions. Mean energy and ablation duration per tumour were 37.6 kJ ± 21.7 (9-87 kJ) and 24.7 min ± 11.1 (7-49 min), respectively. Coagulation zone short- and long-axis diameters were 31.5 mm ± 10.5 (16-65 mm) and 52.7 mm ± 15.4 (27-94 mm), respectively. Two CTCAE-2-complications occurred (pneumothorax, pleural effusion). Seven patients developed new tumour manifestations in the untreated liver. Local tumour progression was not observed. CONCLUSIONS Microwave ablation is feasible under near real-time MR guidance and provides effective treatment of hepatic malignancies in one session. KEY POINTS • Planning, applicator placement and therapy monitoring are possible without using contrast enhancement • Energy transmission from the generator to the scanner room is safely possible • MR-guided microwave ablation provides effective treatment of hepatic malignancies in one session • Therapy monitoring is possible without applicator retraction from the ablation site.
Collapse
Affiliation(s)
- Rüdiger Hoffmann
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany.
| | - Hansjörg Rempp
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - David-Emanuel Keßler
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Jakob Weiß
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Philippe L Pereira
- Department of Radiology, Minimally Invasive Therapies and Nuclear Medicine, SLK-Kliniken Heilbronn GmbH, Am Gesundbrunnen 20-26, 74078, Heilbronn, Germany
| | - Konstantin Nikolaou
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| | - Stephan Clasen
- Department of Diagnostic and Interventional Radiology, Eberhard-Karls-University, Hoppe-Seyler-Strasse 3, 72076, Tübingen, Germany
| |
Collapse
|
20
|
Liu M, Huang J, Xu Y, He X, Li L, Lü Y, Liu Q, Sequeiros RB, Li C. MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open high-field MRI scanner with respiratory gating. Eur Radiol 2016; 27:1459-1466. [PMID: 27516355 DOI: 10.1007/s00330-016-4518-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2016] [Revised: 06/27/2016] [Accepted: 07/19/2016] [Indexed: 12/24/2022]
Abstract
OBJECTIVES To prospectively evaluate the feasibility, safety and accuracy of MR-guided percutaneous biopsy of solitary pulmonary lesions using a 1.0-T open MR scanner with respiratory gating. METHODS Sixty-five patients with 65 solitary pulmonary lesions underwent MR-guided percutaneous coaxial cutting needle biopsy using a 1.0-T open MR scanner with respiratory gating. Lesions were divided into two groups according to maximum lesion diameters: ≤2.0 cm (n = 31) and >2.0 cm (n = 34). The final diagnosis was established in surgery and subsequent histology. Diagnostic accuracy, sensitivity and specificity were compared between the groups using Fisher's exact test. RESULTS Accuracy, sensitivity and specificity of MRI-guided percutaneous pulmonary biopsy in diagnosing malignancy were 96.9 %, 96.4 % and 100 %, respectively. Accuracy, sensitivity and specificity were 96.8 %, 96.3 % and 100 % for lesions 2.0 cm or smaller and 97.1 %, 96.4 % and 100 %, respectively, for lesions larger than 2.0 cm. There was no significant difference between the two groups (P > 0.05). Biopsy-induced complications encountered were pneumothorax in 12.3 % (8/65) and haemoptysis in 4.6 % (3/65). There were no serious complications. CONCLUSIONS MRI-guided percutaneous biopsy using a 1.0-T open MR scanner with respiratory gating is an accurate and safe diagnostic technique in evaluation of pulmonary lesions. KEY POINTS • MRI-guided percutaneous lung biopsy using a 1.0-T open MR scanner is feasibility. • 96.9 % differentiation accuracy of malignant and benign lung lesions is possible. • No serious complications occurred in MRI-guided lung biopsy.
Collapse
Affiliation(s)
- Ming Liu
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Jie Huang
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Yujun Xu
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Xiangmeng He
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Lei Li
- Department of Interventional Radiology, Qingdao Central Hospital, Qingdao, Shandong, People's Republic of China
| | - Yubo Lü
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | - Qiang Liu
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China
| | | | - Chengli Li
- Department of Interventional MRI, Shandong Medical Imaging Research Institute affiliated to Shandong University, Shandong Key Laboratory of Advanced Medical Imaging Technologies and Applications, Jinan, Shandong, People's Republic of China.
| |
Collapse
|
21
|
A novel electrode with electromagnetic tip tracking in ultrasonography-guided radiofrequency ablation: a phantom, ex vivo, and in vivo experimental study. Invest Radiol 2015; 50:81-7. [PMID: 25360604 DOI: 10.1097/rli.0000000000000103] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
OBJECTIVES The objective of this study was to compare the targeting and ablation performance between a newly developed radiofrequency (RF) electrode embedded with an electromagnetic position sensor (EMPS) at the electrode tip and a conventional RF electrode. MATERIALS AND METHODS The institutional animal care and use committee approved this study. The targeting of paint balls within phantoms was performed under ultrasonography guidance by 2 radiologists (beginner vs expert) with an "in-plane" and "out-of-plane" approaches using the new RF electrode and a conventional RF electrode (n = 20 for each method). To evaluate the targeting performance, the electrode placement time and the number of electrode pullbacks for redirection were compared between the 2 electrodes. The ablation performance was also compared by analyzing the ablation volumes in ex vivo bovine and in vivo porcine livers (n = 30 and n = 24, respectively) and the cellular viability of the ablation zone in in vivo specimens. RESULTS In the phantom study, the RF electrode embedded with an EMPS showed a significantly shorter electrode placement time compared with the conventional RF electrode in both the in-plane and out-of-plane approaches by both radiologists (P < 0.05). The electrode pullback rate for both radiologists was lower in the new RF electrode than in the conventional RF electrode, but it did not reach statistical significance in the in-plane approach by the expert (P = 0.059). The ablation volumes analyzed with and without cellular viability in the ex vivo and in vivo studies were not significantly different between the 2 electrodes (P > 0.05). CONCLUSIONS The RF electrode embedded with an EMPS is faster than the conventional electrode in the electrode placement into the target lesions. The ablation performance is not significantly different between the 2 electrodes.
Collapse
|
22
|
Dong J, Zhang L, Li W, Mao S, Wang Y, Wang D, Shen L, Dong A, Wu P. 1.0 T open-configuration magnetic resonance-guided microwave ablation of pig livers in real time. Sci Rep 2015; 5:13551. [PMID: 26315365 PMCID: PMC4551954 DOI: 10.1038/srep13551] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Accepted: 07/01/2015] [Indexed: 12/12/2022] Open
Abstract
The current fastest frame rate of each single image slice in MR-guided ablation is 1.3 seconds, which means delayed imaging for human at an average reaction time: 0.33 seconds. The delayed imaging greatly limits the accuracy of puncture and ablation, and results in puncture injury or incomplete ablation. To overcome delayed imaging and obtain real-time imaging, the study was performed using a 1.0-T whole-body open configuration MR scanner in the livers of 10 Wuzhishan pigs. A respiratory-triggered liver matrix array was explored to guide and monitor microwave ablation in real-time. We successfully performed the entire ablation procedure under MR real-time guidance at 0.202 s, the fastest frame rate for each single image slice. The puncture time ranged from 23 min to 3 min. For the pigs, the mean puncture time was shorted to 4.75 minutes and the mean ablation time was 11.25 minutes at power 70 W. The mean length and widths were 4.62 ± 0.24 cm and 2.64 ± 0.13 cm, respectively. No complications or ablation related deaths during or after ablation were observed. In the current study, MR is able to guide microwave ablation like ultrasound in real-time guidance showing great potential for the treatment of liver tumors.
Collapse
Affiliation(s)
- Jun Dong
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Liang Zhang
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Wang Li
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Siyue Mao
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Yiqi Wang
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Deling Wang
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Lujun Shen
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Annan Dong
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| | - Peihong Wu
- Department of Medical Imaging &Image Guided Therapy, Sun Yat-Sen University Cancer Center; State Key Laboratory of Oncology in South China; Collaborative Innovation Center for Cancer Medicine; East Dong Feng Road 651, Guangzhou, Guangdong 510060, P. R. China
| |
Collapse
|
23
|
Liu M, Sequeiros RB, Xu Y, He X, Zhu T, Li L, Lü Y, Huang J, Li C. MRI-guided percutaneous transpedicular biopsy of thoracic and lumbar spine using a 0.23t scanner with optical instrument tracking. J Magn Reson Imaging 2015; 42:1740-6. [PMID: 25946392 DOI: 10.1002/jmri.24924] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 04/06/2015] [Indexed: 12/11/2022] Open
Affiliation(s)
- Ming Liu
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| | | | - Yujun Xu
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| | - Xiangmeng He
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| | - Tongyin Zhu
- Department of hepatobiliary and pancreatic surgery; First Affiliated Hospital of Zhejiang University; Hangzhou Zhejiang P.R. China
| | - Lei Li
- Department of Interventional Radiology; Qingdao Central Hospital; Qingdao Shandong P.R. China
| | - Yubo Lü
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| | - Jie Huang
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| | - Chengli Li
- Department of Interventional MRI; Shandong Medical Imaging Research Institute, Shandong University; Jinan Shandong P.R. China
| |
Collapse
|
24
|
Yan C, Tan X, Wei Q, Feng R, Li C, Wu Y, Hao P, Chan Q, Xiong W, Xu J, Xu Y. Lung MRI of invasive fungal infection at 3 Tesla: evaluation of five different pulse sequences and comparison with multidetector computed tomography (MDCT). Eur Radiol 2014; 25:550-7. [PMID: 25231132 DOI: 10.1007/s00330-014-3432-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2014] [Revised: 08/20/2014] [Accepted: 09/03/2014] [Indexed: 11/25/2022]
Abstract
OBJECTIVES To evaluate the diagnostic performance of five MR sequences to detect pulmonary infectious lesions in patients with invasive fungal infection (IFI), using multidetector computed tomography (MDCT) as the reference standard. METHODS Thirty-four immunocompromised patients with suspected IFI underwent MDCT and MRI. The MR studies were performed using five pulse sequences at 3.0 T: T2-weighted turbo spin echo (TSE), short-tau inversion recovery (STIR), spectrally selective attenuated inversion recovery (SPAIR), T1-weighted high resolution isotropic volume excitation (e-THRIVE) and T1-weighted fast field echo (T1-FFE). The size, lesion-to-lung contrast ratio and the detectability of pulmonary lesions on MR images were assessed. Image quality and artefacts on different sequences were also rated. RESULTS A total of 84 lesions including nodules (n = 44) and consolidation (n = 40) were present in 75 lobes. SPAIR and e-THRIVE images achieved high overall lesion-related sensitivities for the detection of pulmonary abnormalities (90.5% and 86.9%, respectively). STIR showed the highest lesion-to-lung contrast ratio for nodules (21.8) and consolidation (17.0), whereas TSE had the fewest physiological artefacts. CONCLUSIONS MRI at 3.0 T can depict clinically significant pulmonary IFI abnormalities with high accuracy compared to MDCT. SPAIR and e-THRIVE are preferred sequences for the detection of infectious lesions of 5 mm and larger. KEY POINTS • A radiation-free radiological method is desirable for assessing pulmonary infectious lesions • MRI at 3 T can depict lung infiltrates with good concordance to MDCT • SPAIR and e-THRIVE are favourable sequences for the detection of pulmonary lesions • The greatest benefit is for the diagnosis of lesions larger than 5 mm.
Collapse
Affiliation(s)
- Chenggong Yan
- Department of Medical Imaging Center, Nanfang Hospital, Southern Medical University, No. 1838 Guangzhou Avenue North, Guangzhou, 510515, Guangdong, People's Republic of China
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Colorectal cancer liver metastases: long-term survival and progression-free survival after thermal ablation using magnetic resonance-guided laser-induced interstitial thermotherapy in 594 patients: analysis of prognostic factors. Invest Radiol 2014; 49:48-56. [PMID: 24056114 DOI: 10.1097/rli.0b013e3182a6094e] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
PURPOSE The purpose of this study was the evaluation of prognostic factors for long-term survival and progression-free survival (PFS) after treatment of colorectal cancer (CRC) liver metastases with magnetic resonance-guided laser-induced interstital thermotherapy (LITT). PATIENTS AND METHODS We included 594 patients (mean age, 61.2 years) with CRC liver metastases who were treated with LITT. The statistical analysis of the long-term survival and PFS were based on the Kaplan-Meier method. The Cox regression model tested different parameters that could be of prognostic value. The tested prognostic factors were the following: sex, age, the location of primary tumor, the number of metastases, the maximal diameter and total volume of metastases and necroses, the quotient of total volumes of metastases and necroses, the time of appearance of liver metastases and location in the liver, the TNM classification of CRC, extrahepatic metastases, and neoadjuvant treatments. RESULTS The median survival was 25 months starting from the date of the first LITT. The 1-, 2-, 3-, 4-, and 5-year survival rates were 78%, 50.1%, 28%, 16.4%, and 7.8%, respectively. The median PFS was 13 months. The 1-, 2-, 3-, 4-, and 5-year PFS rates were 51.3%, 35.4%, 30.7%, 25.4%, and 22.3%, respectively. The number of metastases and their maximal diameter were the most important prognostic factors for both long-term survival and PFS. Long-term survival was also highly influenced by the initial involvement of the lymph nodes. CONCLUSIONS For patients treated with LITT for CRC liver metastases, the number and size of metastases, together with the initial lymph node status, are significant prognostic factors for long-term survival.
Collapse
|
26
|
Transcatheter CT Arterial Portography and CT Hepatic Arteriography for Liver Tumor Visualization during Percutaneous Ablation. J Vasc Interv Radiol 2014; 25:1101-1111.e4. [DOI: 10.1016/j.jvir.2014.02.008] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2013] [Revised: 01/31/2014] [Accepted: 02/03/2014] [Indexed: 12/24/2022] Open
|
27
|
Mei CS, Chu R, Hoge WS, Panych LP, Madore B. Accurate field mapping in the presence of B0 inhomogeneities, applied to MR thermometry. Magn Reson Med 2014; 73:2142-51. [PMID: 24975329 DOI: 10.1002/mrm.25338] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2014] [Revised: 06/03/2014] [Accepted: 06/05/2014] [Indexed: 11/06/2022]
Abstract
PURPOSE To describe how B0 inhomogeneities can cause errors in proton resonance frequency (PRF) shift thermometry, and to correct for these errors. METHODS With PRF thermometry, measured phase shifts are converted into temperature measurements through the use of a scaling factor proportional to the echo time, TE. However, B0 inhomogeneities can deform, spread, and translate MR echoes, potentially making the "true" echo time vary spatially within the imaged object and take on values that differ from the prescribed TE value. Acquisition and reconstruction methods able to avoid or correct for such errors are presented. RESULTS Tests were performed in a gel phantom during sonication, and temperature measurements were made with proper shimming as well as with intentionally introduced B0 inhomogeneities. Errors caused by B0 inhomogeneities were observed, described, and corrected by the proposed methods. No statistical difference was found between the corrected results and the reference results obtained with proper shimming, while errors by more than 10% in temperature elevation were corrected for. The approach was also applied to an abdominal in vivo dataset. CONCLUSION Field variations induce errors in measured field values, which can be detected and corrected. The approach was validated for a PRF thermometry application.
Collapse
Affiliation(s)
- Chang-Sheng Mei
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.,Department of Physics, Soochow University, Taipei, Taiwan, Republic of China
| | - Renxin Chu
- Department of Neurology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - W Scott Hoge
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Lawrence P Panych
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Bruno Madore
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
28
|
Magnetic resonance-guided laser-induced interstitial thermotherapy of breast cancer liver metastases and other noncolorectal cancer liver metastases: an analysis of prognostic factors for long-term survival and progression-free survival. Invest Radiol 2014; 48:406-12. [PMID: 23385401 DOI: 10.1097/rli.0b013e31828328d7] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE The purpose of this study was the evaluation of prognostic factors for long-term survival and progression-free survival (PFS) after treatment of noncolorectal cancer liver metastases through MR-guided laser-induced thermotherapy (LITT). PATIENTS AND METHODS We included 401 patients (mean age, 57.3 years) with liver metastases from different primary tumors who were treated with LITT. Long-term survival and progression-free-survival rates were evaluated using the Kaplan-Meier method. A Cox regression model tested different parameters that could be of prognostic value. The tested prognostic factors were as follows: the location of primary tumor, TNM classification, extrahepatic metastases, hepatic resection or neoadjuvant transarterial chemoembolization or systemic chemotherapy before LITT, the number of initial metastases, the volume of metastases, and the quotient of total volumes of metastases and necroses per patient. RESULTS The median survival was 37.6 months starting from the date of LITT. The 1-, 2-, 3-, 4-, and 5-year survival rates were 86.5%, 67.2%, 51.9%, 39.9%, and 33.4%, respectively. The median PFS was 12.2 months. The 1-, 2-, 3-, 4-, and 5-year PFS rates were 50.6%, 33.8%, 26%, 20.4%, and 17%, respectively. The initial number of metastases, the volumes of metastases, and the quotient of the volumes of metastases and necroses influenced the long-term survival and the PFS. CONCLUSIONS Laser-induced thermotherapy is a minimally invasive method in the treatment of hepatic metastases of noncolorectal cancer, and it shows good results in long-term survival and PFS. The initial number of metastases and their volume are the most important prognostic factors. The status of the lymph nodes, the existence of other extrahepatic metastases, the location of the primary tumor, and different neoadjuvant therapies are of nonprognostic value.
Collapse
|
29
|
Fischbach F, Fischbach K, Ricke J. [Percutaneous interventions in an open MR system: technical background and clinical indications]. Radiologe 2013; 53:993-1000. [PMID: 24170286 DOI: 10.1007/s00117-012-2462-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The latest and therefore more efficient open magnetic resonance (MR) scanners with a field strength of 1 T allow freehand fluoroscopic interventions with excellent image quality. Specifically designed interactive software simplifies examination planning and performance. Guidance in two imaging planes allows fast and accurate device positioning and interventional procedures during free breathing. The diagnostic and therapeutic spectrum includes a wide variety of interstitial percutaneous interventions. The most important are periradicular therapy (PRT), intra-abdominal drainage and nephrostoma placement, biopsies, especially in the breasts and liver and focal ablation therapy of malignant hepatic or renal lesions. As the approach is fast and robotic devices are not needed the method is increasingly being carried out in the clinical routine. A drawback of MR-guided interventions is the limitation in verbal communication during image acquisition. Furthermore, the portfolio of MR compatible instruments needs to be extended.
Collapse
Affiliation(s)
- F Fischbach
- Klinik für Radiologie und Nuklearmedizin, Universitätsklinikum Magdeburg, Leipziger Str. 44, 39120, Magdeburg, Deutschland,
| | | | | |
Collapse
|