1
|
Auti OB, Bandekar K, Kamat N, Raj V. Cardiac magnetic resonance techniques: Our experience on wide bore 3 tesla magnetic resonance system. Indian J Radiol Imaging 2021; 27:404-412. [PMID: 29379234 PMCID: PMC5761166 DOI: 10.4103/ijri.ijri_503_16] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023] Open
Abstract
Cardiovascular magnetic resonance (CMR) has become a widely adapted imaging modality in the diagnosis and management of patients with cardiovascular diseases. It provides unparalleled data of cardiac function and myocardial morphology. Majority of CMR imaging is currently being performed on 1.5 Tesla (T) MR systems. Over the last many years, the cardiac imaging protocols have been standardized and optimized in the 1.5T systems. 3T MR systems are now being used more and more in small and large institutions in our country due to their proven advantages in the field of neuro, body, and musculoskeletal imaging. Cardiac imaging on 3T system can be a double-edged sword. On one hand, it may provide nondiagnostic images due to significant artifacts, and on the other hand, it may complete the examination in quick time and provide excellent quality images. It is therefore important for the user to be aware of the potential pitfalls of CMR in 3T systems and also the necessary steps to avoid them. In this study, we discuss various challenges and advantages of performing CMR in a 3T system. We also present potential technical solutions to improve the image quality.
Collapse
Affiliation(s)
- Onkar B Auti
- Department of Radio-diagnosis, Narayana Health City, Bengaluru, Karnataka, India.,Department of Radio-diagnosis, Jupiter Hospital, Thane, Maharashtra, India
| | - Kalashree Bandekar
- Department of Radio-diagnosis, Jupiter Hospital, Thane, Maharashtra, India
| | - Nikhil Kamat
- Department of Radio-diagnosis, Jupiter Hospital, Thane, Maharashtra, India
| | - Vimal Raj
- Department of Radio-diagnosis, Narayana Health City, Bengaluru, Karnataka, India
| |
Collapse
|
2
|
|
3
|
Feeney D, Sharkey L, Steward S, Bahr K, Henson M, Ito D, O'Brien T, Jessen C, Husbands B, Borgatti A, Modiano J. Applicability of 3T Body MRI in Assessment of Nonfocal Bone Marrow Involvement of Hematopoietic Neoplasia in Dogs. J Vet Intern Med 2013; 27:1165-71. [DOI: 10.1111/jvim.12151] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2013] [Revised: 04/22/2013] [Accepted: 06/06/2013] [Indexed: 02/06/2023] Open
Affiliation(s)
- D.A. Feeney
- Department of Veterinary Clinical Sciences; University of Minnesota; St. Paul MN
| | - L.C. Sharkey
- Masonic Cancer Center; University of Minnesota; St. Paul MN
| | - S.M. Steward
- Veterinary Medical Center; University of Minnesota; St. Paul MN
| | - K.L. Bahr
- Metropolitan Veterinary Hospital; Akron OH
| | - M.S. Henson
- Masonic Cancer Center; University of Minnesota; St. Paul MN
| | - D. Ito
- Masonic Cancer Center; University of Minnesota; St. Paul MN
| | - T.D. O'Brien
- Department of Veterinary Population Medicine; University of Minnesota; St. Paul MN
| | - C.R. Jessen
- Department of Veterinary Clinical Sciences; University of Minnesota; St. Paul MN
| | | | - A. Borgatti
- Masonic Cancer Center; University of Minnesota; St. Paul MN
| | - J. Modiano
- Masonic Cancer Center; University of Minnesota; St. Paul MN
| |
Collapse
|
4
|
Hays AG, Schär M, Kelle S. Clinical applications for cardiovascular magnetic resonance imaging at 3 tesla. Curr Cardiol Rev 2011; 5:237-42. [PMID: 20676283 PMCID: PMC2822147 DOI: 10.2174/157340309788970351] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/05/2008] [Revised: 03/18/2009] [Accepted: 03/19/2009] [Indexed: 12/03/2022] Open
Abstract
Cardiovascular magnetic resonance (CMR) imaging has evolved rapidly and is now accepted as a powerful diagnostic tool with significant clinical and research applications. Clinical 3 Tesla (3 T) scanners are increasingly available and offer improved diagnostic capabilities compared to 1.5 T scanners for perfusion, viability, and coronary imaging. Although technical challenges remain for cardiac imaging at higher field strengths such as balanced steady state free precession (bSSFP) cine imaging, the majority of cardiac applications are feasible at 3 T with comparable or superior image quality to that of 1.5 T. This review will focus on the benefits and limitations of 3 T CMR for common clinical applications and examine areas in development for potential clinical use.
Collapse
Affiliation(s)
- Allison G Hays
- Department of Medicine, Division of Cardiology, Johns Hopkins University, Baltimore, Maryland, USA
| | | | | |
Collapse
|
5
|
MR and CT: When to Use Each. CURRENT CARDIOVASCULAR IMAGING REPORTS 2011. [DOI: 10.1007/s12410-011-9071-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
6
|
Oshinski JN, Delfino JG, Sharma P, Gharib AM, Pettigrew RI. Cardiovascular magnetic resonance at 3.0 T: current state of the art. J Cardiovasc Magn Reson 2010; 12:55. [PMID: 20929538 PMCID: PMC2964699 DOI: 10.1186/1532-429x-12-55] [Citation(s) in RCA: 69] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2010] [Accepted: 10/07/2010] [Indexed: 12/12/2022] Open
Abstract
There are advantages to conducting cardiovascular magnetic resonance (CMR) studies at a field strength of 3.0 Telsa, including the increase in bulk magnetization, the increase in frequency separation of off-resonance spins, and the increase in T1 of many tissues. However, there are significant challenges to routinely performing CMR at 3.0 T, including the reduction in main magnetic field homogeneity, the increase in RF power deposition, and the increase in susceptibility-based artifacts.In this review, we outline the underlying physical effects that occur when imaging at higher fields, examine the practical results these effects have on the CMR applications, and examine methods used to compensate for these effects. Specifically, we will review cine imaging, MR coronary angiography, myocardial perfusion imaging, late gadolinium enhancement, and vascular wall imaging.
Collapse
Affiliation(s)
- John N Oshinski
- Department of Radiology, Emory University School of Medicine, 1364 Clifton Road, Room AG34, Atlanta, GA 30322, USA
- Department of Biomedical Engineering, Emory University and the Georgia Institute of Technology, 101 Woodruff Circle Woodruff Memorial Building, Suite 2001, Atlanta, Georgia 30322, USA
| | - Jana G Delfino
- Department of Radiology, Emory University School of Medicine, 1364 Clifton Road, Room AG34, Atlanta, GA 30322, USA
| | - Puneet Sharma
- Department of Radiology, Emory University School of Medicine, 1364 Clifton Road, Room AG34, Atlanta, GA 30322, USA
| | - Ahmed M Gharib
- Laboratory of Integrative Cardiovascular Imaging, Department of Radiology, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Clinical Research Center, Bldg. 10, Rm. 3-5340, MSC 1263, 10 Center Dr., Bethesda, MD 20892, USA
| | - Roderic I Pettigrew
- Laboratory of Integrative Cardiovascular Imaging, Department of Radiology, National Institute of Diabetes and Digestive and Kidney Diseases, National Institutes of Health, Clinical Research Center, Bldg. 10, Rm. 3-5340, MSC 1263, 10 Center Dr., Bethesda, MD 20892, USA
| |
Collapse
|
7
|
Kim YJ. High field strength magnetic resonance imaging of cardiovascular diseases. JOURNAL OF THE KOREAN MEDICAL ASSOCIATION 2010. [DOI: 10.5124/jkma.2010.53.12.1059] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Young Jin Kim
- Department of Radiology, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
8
|
[Update on cardiac imaging techniques: echocardiography, cardiac magnetic resonance, and multidetector computed tomography]. Rev Esp Cardiol 2009; 62 Suppl 1:129-50. [PMID: 19174056 DOI: 10.1016/s0300-8932(09)70047-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
This article contains a review of the most important publications on cardiac imaging that have appeared during 2008. During the year, we assisted with the clinical implementation of three-dimensional real-time transesophageal echocardiography, with the use of echocardiography for selecting patients for and monitoring those who underwent percutaneous aortic valve replacement (the majority of centers performing the technique were still in the learning phase), and with the emergence in the clinic of techniques for studying myocardial deformation. Also reviewed are the most significant developments in the application of echocardiography to coronary heart disease and cardiac resynchronization therapy and in 2 other techniques whose use is constantly increasing: cardiac magnetic resonance and multidetector cardiac computed tomography. The review ends with a description of the current state of the art in contrast echocardiography, with particular emphasis on safety in the context of recommendations made by the US Food and Drug Administration at the end of 2007.
Collapse
|
9
|
Machann J, Schlemmer HP, Schick F. Technical challenges and opportunities of whole-body magnetic resonance imaging at 3T. Phys Med 2008; 24:63-70. [DOI: 10.1016/j.ejmp.2008.01.011] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2007] [Revised: 01/09/2008] [Accepted: 01/15/2008] [Indexed: 11/25/2022] Open
|
10
|
Abstract
Cardiovascular magnetic resonance (CMR) imaging at 3 T has started to demonstrate real clinical advantages compared to cardiac imaging at 1.5 T. This article provides an overview of 3 T CMR imaging and its clinical use in the diagnosis of cardiovascular diseases. In addition, an outlook is given on new and improved applications to fully utilize the advantages connected to the higher field strength.
Collapse
Affiliation(s)
- Sebastian Kelle
- Department of Internal Medicine/Cardiology, Deutsches Herzzentrum Berlin, Berlin, Germany
| | | |
Collapse
|
11
|
Wieben O, Francois C, Reeder SB. Cardiac MRI of ischemic heart disease at 3 T: potential and challenges. Eur J Radiol 2008; 65:15-28. [PMID: 18077119 DOI: 10.1016/j.ejrad.2007.10.022] [Citation(s) in RCA: 76] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2007] [Accepted: 10/30/2007] [Indexed: 12/17/2022]
Abstract
Cardiac MRI has become a routinely used imaging modality in the diagnosis of cardiovascular disease and is considered the clinically accepted gold standard modality for the assessment of cardiac function and myocardial viability. In recent years, commercially available clinical scanners with a higher magnetic field strength (3.0 T) and dedicated multi-element coils have become available. The superior signal-to-noise ratio (SNR) of these systems has lead to their rapid acceptance in cranial and musculoskeletal MRI while the adoption of 3.0 T for cardiovascular imaging has been somewhat slower. This review article describes the benefits and pitfalls of magnetic resonance imaging of ischemic heart disease at higher field strengths. The fundamental changes in parameters such as SNR, transversal and longitudinal relaxation times, susceptibility artifacts, RF (B1) inhomogeneity, and specific absorption rate are discussed. We also review approaches to avoid compromised image quality such as banding artifacts and inconsistent or suboptimal flip angles. Imaging sequences for the assessment of cardiac function with CINE balanced SSFP imaging and MR tagging, myocardial perfusion, and delayed enhancement and their adjustments for higher field imaging are explained in detail along with several clinical examples. We also explore the use of parallel imaging at 3.0 T to improve cardiac imaging by trading the SNR gain for higher field strengths for acquisition speed with increased coverage or improved spatial and temporal resolution. This approach is particularly useful for dynamic applications that are usually limited to the duration of a single breath-hold.
Collapse
Affiliation(s)
- Oliver Wieben
- Department of Radiology, University of Wisconsin, Madison, WI 53792-3252, United States.
| | | | | |
Collapse
|
12
|
Artifacts in 3-T MRI: Physical background and reduction strategies. Eur J Radiol 2008; 65:29-35. [PMID: 18162353 DOI: 10.1016/j.ejrad.2007.11.005] [Citation(s) in RCA: 184] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2007] [Accepted: 11/05/2007] [Indexed: 01/26/2023]
|