1
|
Sammarra M, Piccolo CL, Sarli M, Stefanucci R, Tommasiello M, Orsaria P, Altomare V, Beomonte Zobel B. Contrast-Enhanced Mammography-Guided Biopsy: Preliminary Results of a Single-Center Retrospective Experience. J Clin Med 2024; 13:933. [PMID: 38398247 PMCID: PMC10889410 DOI: 10.3390/jcm13040933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/02/2024] [Accepted: 02/03/2024] [Indexed: 02/25/2024] Open
Abstract
Background: CEM-guided breast biopsy is an advanced diagnostic procedure that takes advantage of the ability of CEM to enhance suspicious breast lesions. The aim pf this paper is to describe a single-center retrospective experience on CEM-guided breast biopsy in terms of procedural features and histological outcomes. Methods: 69 patients underwent the procedure. Patient age, breast density, presentation, dimensions, and lesion target enhancement were recorded. All the biopsy procedures were performed using a 7- or 10-gauge (G) vacuum-assisted biopsy needle. The procedural approach (horizontal or vertical) and the decubitus of the patient (lateral or in a sitting position) were noted. Results: A total of 69 patients underwent a CEM-guided biopsy. Suspicious lesions presented as mass enhancement in 35% of cases and non-mass enhancement in 65% of cases. The median size of the target lesions was 20 mm. The median procedural time for each biopsy was 10 ± 4 min. The patients were placed in a lateral decubitus position in 52% of cases and seated in 48% of cases. The most common approach was horizontal (57%). The mean AGD was 14.8 mGy. At histology, cancer detection rate was 28% (20/71). Conclusions: CEM-guided biopsy was feasible, with high procedure success rates and high tolerance by the patients.
Collapse
Affiliation(s)
- Matteo Sammarra
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Claudia Lucia Piccolo
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Marina Sarli
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Rita Stefanucci
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Manuela Tommasiello
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Paolo Orsaria
- Department of Breast Surgery, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
| | - Vittorio Altomare
- Department of Breast Surgery, Campus Bio-Medico University, 00128 Rome, Italy
| | - Bruno Beomonte Zobel
- Department of Radiology, Fondazione Policlinico Universitario Campus Bio-Medico, 00128 Rome, Italy
- Research Unit of Radiology, Department of Medicine and Surgery, Università Campus Bio-Medico di Roma, Via Alvaro del Portillo, 21, 00128 Rome, Italy
| |
Collapse
|
2
|
Żydowicz WM, Skokowski J, Marano L, Polom K. Current Trends and Beyond Conventional Approaches: Advancements in Breast Cancer Surgery through Three-Dimensional Imaging, Virtual Reality, Augmented Reality, and the Emerging Metaverse. J Clin Med 2024; 13:915. [PMID: 38337610 PMCID: PMC10856583 DOI: 10.3390/jcm13030915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2024] [Revised: 01/25/2024] [Accepted: 02/03/2024] [Indexed: 02/12/2024] Open
Abstract
Breast cancer stands as the most prevalent cancer globally, necessitating comprehensive care. A multidisciplinary approach proves crucial for precise diagnosis and treatment, ultimately leading to effective disease management. While surgical interventions continue to evolve and remain integral for curative treatment, imaging assumes a fundamental role in breast cancer detection. Advanced imaging techniques not only facilitate improved diagnosis but also contribute significantly to the overall enhancement of breast cancer management. This review article aims to provide an overview of innovative technologies such as virtual reality, augmented reality, and three-dimensional imaging, utilized in the medical field to elevate the diagnosis and treatment of breast cancer. Additionally, the article delves into an emerging technology known as the metaverse, still under development. Through the analysis of impactful research and comparison of their findings, this study offers valuable insights into the advantages of each innovative technique. The goal is to provide physicians, surgeons, and radiologists with information on how to enhance breast cancer management.
Collapse
Affiliation(s)
- Weronika Magdalena Żydowicz
- Department of General Surgery and Surgical Oncology, “Saint Wojciech” Hospital, “Nicolaus Copernicus” Health Center, Jana Pawła II 50, 80-462 Gdańsk, Poland; (W.M.Ż.); (J.S.)
| | - Jaroslaw Skokowski
- Department of General Surgery and Surgical Oncology, “Saint Wojciech” Hospital, “Nicolaus Copernicus” Health Center, Jana Pawła II 50, 80-462 Gdańsk, Poland; (W.M.Ż.); (J.S.)
- Department of Medicine, Academy of Applied Medical and Social Sciences, Akademia Medycznych I Spolecznych Nauk Stosowanych (AMiSNS), 2 Lotnicza Street, 82-300 Elbląg, Poland;
| | - Luigi Marano
- Department of General Surgery and Surgical Oncology, “Saint Wojciech” Hospital, “Nicolaus Copernicus” Health Center, Jana Pawła II 50, 80-462 Gdańsk, Poland; (W.M.Ż.); (J.S.)
- Department of Medicine, Academy of Applied Medical and Social Sciences, Akademia Medycznych I Spolecznych Nauk Stosowanych (AMiSNS), 2 Lotnicza Street, 82-300 Elbląg, Poland;
| | - Karol Polom
- Department of Medicine, Academy of Applied Medical and Social Sciences, Akademia Medycznych I Spolecznych Nauk Stosowanych (AMiSNS), 2 Lotnicza Street, 82-300 Elbląg, Poland;
- Department of Gastrointestinal Surgical Oncology, Greater Poland Cancer Centre, Garbary 15, 61-866 Poznan, Poland
| |
Collapse
|
3
|
Yalnız C, Rosenblat J, Spak D, Wei W, Scoggins M, Le-Petross C, Dryden MJ, Adrada B, Doğan BE. Association of Retrospective Peer Review and Positive Predictive Value of Magnetic Resonance Imaging-Guided Vacuum-Assisted Needle Biopsies of Breast. Eur J Breast Health 2019; 15:229-234. [PMID: 31620681 DOI: 10.5152/ejbh.2019.5002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2019] [Accepted: 06/30/2019] [Indexed: 12/17/2022]
Abstract
Objective To evaluate the association between retrospective peer review of breast magnetic resonance imaging-guided vacuum-assisted needle biopsies and positive predictive value of subsequent magnetic resonance imaging-guided biopsies. Materials and Methods In January, 2015, a weekly conference was initiated in our institution to evaluate all breast magnetic resonance imaging-guided vacuum-assisted needle biopsies performed over January 1, 2014-December 31, 2015. During this weekly conferences, breast dynamic contrast-enhanced magnetic resonance imaging findings of 6 anonymized cases were discussed and then the faculty voted on whether they agree with the biopsy indication, accurate sampling and radiology-pathology correlation. We retrospectively reviewed and compared the magnetic resonance imaging indication, benign or malignant pathology rates, lesion types and the positive predictive value of magnetic resonance imaging-guided vacuum-assisted needle biopsy in the years before and after initiating this group peer review. Results The number of dynamic contrast-enhanced magnetic resonance imaging and magnetic resonance imaging-guided vacuum-assisted needle biopsies before and after initiating the review were 1447 vs 1596 (p=0.0002), and 253 (17.5%) vs 203 (12.7%) (p=0.04), respectively. There was a significant decrease in the number of benign biopsies in 2015 (n=104) compared to 2014 (n=154, p=0.04). The positive predictive value of magnetic resonance imaging-guided biopsy significantly increased after group review was implemented (Positive predictive value in 2014=%39.1 and positive predictive value in 2015=%48.8) (p=0.03), although the indications (p=0.49), history of breast cancer (p=0.14), biopsied magnetic resonance imaging lesion types (p=0.53) were not different. Less surgical excision was performed on magnetic resonance imaging-guided vacuum-assisted needle biopsy identified high-risk lesions in 2015 (p=0.25). Conclusion Our study showed an association between retrospective peer review of past biopsies and increased positive predictive value of magnetic resonance imaging-guided vacuum-assisted needle biopsies in our institution.
Collapse
Affiliation(s)
- Ceren Yalnız
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Juliana Rosenblat
- Department of Diagnostic Radiology, Memorial Healthcare System, Hollywood, FL, USA
| | - David Spak
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Wei Wei
- Taussig Cancer Institute Cleveland Clinic, Biostatistics, Cleveland, OH, USA
| | - Marion Scoggins
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Carisa Le-Petross
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Mark J Dryden
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Beatriz Adrada
- Department of Diagnostic Radiology, University of Texas M. D. Anderson Cancer Center, Houston, TX, USA
| | - Başak E Doğan
- Department of Radiology, Division of Breast Imaging, University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
4
|
Schnitt SJ. Problematic issues in breast core needle biopsies. Mod Pathol 2019; 32:71-76. [PMID: 30600318 DOI: 10.1038/s41379-018-0137-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2018] [Accepted: 07/22/2018] [Indexed: 11/09/2022]
Abstract
Image-directed core needle biopsies of the breast are routinely used in current clinical practice for the initial assessment of non-palpable breast lesions. This article provides an update on several important issues regarding evaluation of breast core needle biopsies.
Collapse
Affiliation(s)
- Stuart J Schnitt
- Department of Pathology, Brigham and Women's Hospital and Harvard Medical School, Dana-Farber Cancer Institute, Boston, MA, USA.
| |
Collapse
|
5
|
Carneiro GDAC, Pereira FPA, Lopes FPPL, Calas MJG. Magnetic resonance imaging-guided vacuum-assisted breast biopsy: experience and preliminary results of 205 procedures. Radiol Bras 2018; 51:351-357. [PMID: 30559551 PMCID: PMC6290746 DOI: 10.1590/0100-3984.2017.0132] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/02/2022] Open
Abstract
Objective To demonstrate the frequency of malignancy and histological characteristics
of lesions in patients submitted to vacuum-assisted breast biopsy guided by
magnetic resonance imaging (MRI). Materials and Methods This was a retrospective study of MRI-guided vacuum-assisted breast biopsies
performed between April 2008 and December 2016, in which we analyzed
clinical and epidemiological data, as well as the BI-RADS classification and
histopathological results. We compared nodules and non-nodular enhancements,
in terms of their correlation with malignancy, using chi-square test. Results Among 215 cases referred for MRI-guided vacuum-assisted breast biopsy, the
procedure was contraindicated in 10 cases (5%) and was technically feasible
in the remaining 205 (95%). Non-nodular enhancements were observed in 135
cases (66%), and nodules were observed in 70 (34%), with a mean diameter of
2.2 cm (range, 0.5-9.6 cm) and 0.97 cm (range, 0.5-2.2 cm), respectively. Of
the 205 lesions analyzed, 43 (21%) were malignant, 129 (63%) were benign,
and 33 (16%) were classified as high-risk lesions. The most common
histological findings were invasive ductal carcinoma and, in high-risk
cases, lobular neoplasia. There was no significant difference between
nodules and non-nodular enhancements in terms of the rate of malignancy
(p = 0.725). Conclusion In our sample, the overall malignancy rate was 21%. However, to improve the
assessment of these results, it is necessary to correlate them with the
surgical data and with data from the follow-up of benign cases.
Collapse
|
6
|
Abstract
The use of magnetic resonance imaging (MRI) for image-guided intervention poses both great opportunity and challenges. Although MRI is distinguished by its excellent contrast resolution and lack of ionizing radiation, it was not till the 1990s that technologic innovations allowed for adoption of MRI as a guidance modality for intervention. With advances in magnet, protocol, coil, biopsy needle, and ablation probe design, MRI has emerged as a viable, and increasingly, preferable alternative to other image guidance modalities. With the development of targeting software, augmented reality, robotic assist devices, and MR thermometry, the future of MRI-guided interventions remains promising.
Collapse
Affiliation(s)
- Farzad Sedaghat
- Division of Abdominal Imaging and Intervention, Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA
| | | |
Collapse
|
7
|
Safety and Efficacy of Magnetic Resonance-Guided Vacuum-Assisted Large-Volume Breast Biopsy (MR-Guided VALB). Invest Radiol 2017; 52:186-193. [PMID: 27861232 DOI: 10.1097/rli.0000000000000331] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE Magnetic resonance (MR)-guided vacuum-biopsy is technically demanding and may fail depending on target-lesion size or breast size, and location of lesions within the breast. We developed an MR-guided vacuum-assisted biopsy protocol that collects larger amounts of tissue, aiming at an at least partial or complete ablation of the target-lesion, just as it is intended during surgical (excisional) biopsy. Rationale is to avoid biopsy failures (false-negative results due to undersampling) by collecting larger amounts of tissue. We report on our experience with MR-guided vacuum-assisted large-volume breast biopsy (VALB) (MR-guided VALB) with regard to clinical success and complication rates. MATERIALS Institutional review board-approved analysis of 865 patients with 1414 MR imaging (MRI)-only breast lesions who underwent tissue sampling under MRI guidance. Magnetic resonance-guided VALB was performed on a 1.5 T-system with a 9G system. Per target lesion, we collected at least 24 samples, with the biopsy notch directed toward the position of the target until on postbiopsy control imaging the target lesion appeared completely or at least greatly removed. The standard-of-reference was established by at least 24-months follow-up (for benign biopsy results), or results of surgical histology (for malignant or borderline results). We investigated the technical success rates as a function of factors that usually interfere with MR-guided vacuum biopsy. RESULTS Target lesions were located in the central versus peripheral parts of the breast in 66.6% (941/1414) versus 33.6% (473/1414), occurred in large, intermediate, or small breasts in 22.7% (321/1414), 56.4% (797/1414), or 20.9% (296/1414), corresponded to nonmass enhancement (NME) versus mass enhancement (ME) in 64.0% (905/1414) vs. 36.0% (509/1414), with an average size of 23 mm for NME versus 9 mm for ME, respectively. Primary technical failures, that is, inability to reach the target lesion occurred in 0.2% of patients (2/865) and 0.1% of target lesions (2/1414). Successful biopsy, that is, an MR-guided VALB diagnosis matching with the standard of reference, was achieved in 99.5% (859/863) of patients and 99.7% (1408/1412) target lesions that had been amenable to MR-guided VALB. In 0.5% of patients (4/863) and 0.3% of target lesions (4/1412), a radiologic-pathologic mismatch suggested a false-negative biopsy, confirmed by secondary excisional biopsy. The likelihood of failure was independent of the lesion's location in the breast, breast size, target lesion size, or target lesion type (NME vs ME). None of the patients with benign MR-guided VALB diagnoses developed breast cancer at the biopsy site during follow-up of 2 years. None of the patients developed major complications. CONCLUSION Magnetic resonance-guided VALB is a safe procedure that is associated with a high success rate (99.7%) that is independent of the size, type, or location of a target lesion, or the size of the breast, and is associated with a very low complication rate.
Collapse
|
8
|
Kılıç F, Eren A, Tunç N, Velidedeoğlu M, Bakan S, Aydoğan F, Çelik V, Gazioğlu E, Yılmaz MH. Magnetic Resonance Imaging Guided Vacuum Assisted and Core Needle Biopsies. THE JOURNAL OF BREAST HEALTH 2016; 12:25-30. [PMID: 28331727 DOI: 10.5152/tjbh.2015.2769] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Accepted: 10/26/2015] [Indexed: 11/22/2022]
Abstract
OBJECTIVE The purpose of this study to present the results of Magnetic resonance imaging (MRI) guided cutting needle biopsy procedures of suspicious breast lesions that can be solely detected on Magnetic resonance (MR) examination. MATERIALS AND METHODS The study included 48 patients with 48 lesions which were solely be observed in breast MRI, indistinguishable in ultrasonography and mammography, for MR guided vacuum-assisted cutting needle biopsy and 42 patients with 42 lesions for MR guided cutting needle biopsy for the lesions of the same nature. MR imaging was performed using a 1.5-Tesla MRI device. Acquired MR images were determined and biopsy protocol was performed using computer-aided diagnosis system on the workstation. Vacuum biopsies were performed using 10 G or 12 G automatic biopsy systems, cutting needle biopsy procedures were performed using fully automated 12 G biopsy needle. RESULTS All biopsy procedures were finalized successfully without major complications. The lesions were 54 mass (60%), 28 were non-mass contrast enhancement (31%) and 8 were foci (9%) in the MR examination. Histopathological evaluation revealed 18 malignant (invasive, in-situ ductal carcinoma and lobular carcinoma), 66 benign (apocrine metaplasia, fibrosis, fibroadenomatoid lesion, sclerosing adenosis, fibrocystic disease and mild-to-severe epithelial proliferation) and 6 high-risk (atypical ductal hyperplasia, intraductal papilloma, radial scar) lesions. CONCLUSION Magnetic resonance guided vacuum and cutting needle biopsy methods are successful methods fort he evaluation of solely MRI detected suspicious breast lesions. There are several advantages relative to each other in both methods.
Collapse
Affiliation(s)
- Fahrettin Kılıç
- Department of Radiology, İstanbul University Faculty of Medicine, İstanbul, Turkey
| | - Abdulkadir Eren
- Department of Radiology, İstanbul Medipol University, İstanbul, Turkey
| | - Necmettin Tunç
- Clinic of Radiology, Memorial Hospital, Diyarbakır, Turkey
| | - Mehmet Velidedeoğlu
- Department of General Surgery, İstanbul University Cerrahpaşa Faculty of Medicine, İstanbul, Turkey
| | - Selim Bakan
- Department of Radiology, İstanbul University Faculty of Medicine, İstanbul, Turkey
| | - Fatih Aydoğan
- Department of General Surgery, İstanbul University Cerrahpaşa Faculty of Medicine, İstanbul, Turkey
| | - Varol Çelik
- Department of General Surgery, İstanbul University Cerrahpaşa Faculty of Medicine, İstanbul, Turkey
| | - Ertuğrul Gazioğlu
- Department of General Surgery, İstanbul University Cerrahpaşa Faculty of Medicine, İstanbul, Turkey
| | - Mehmet Halit Yılmaz
- Department of Radiology, İstanbul University Faculty of Medicine, İstanbul, Turkey
| |
Collapse
|
9
|
Closed-Bore Interventional MRI: Percutaneous Biopsies and Ablations. AJR Am J Roentgenol 2015; 205:W400-10. [DOI: 10.2214/ajr.15.14732] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
10
|
Bahrs S, Hattermann V, Preibsch H, Hahn M, Staebler A, Claussen C, Siegmann-Luz K. MR imaging-guided vacuum-assisted breast biopsy: Reduction of false-negative biopsies by short-term control MRI 24–48 h after biopsy. Clin Radiol 2014; 69:695-702. [DOI: 10.1016/j.crad.2014.02.003] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2013] [Revised: 02/16/2014] [Accepted: 02/19/2014] [Indexed: 11/25/2022]
|
11
|
Abstract
The indications, technique, results and limitations of MRI vacuum-assisted breast biopsies are discussed from a review of the literature. This was initially a home-grown technique and its development was slowed down by several factors. As a result of major technical advances, it has become a reliable and very consistent procedure with a low rate of underestimation. It is now an undisputed technique when suspicious MRI enhancement is seen with no corresponding mammography or ultrasound features.
Collapse
Affiliation(s)
- R Plantade
- Nice Europe Imaging Centre, 15, rue Alberti, 06000 Nice, France.
| | - I Thomassin-Naggara
- Department of Radiology, Tenon Hospital, Paris Public Hospitals Health Service (AP-HP), Pierre et Marie Curie University Oncology Institute, 4, rue de la Chine, 75020 Paris, France
| |
Collapse
|
12
|
Zaun G, Zahedi Y, Maderwald S, Orzada S, Pütter C, Scherag A, Winterhager E, Ladd ME, Grümmer R. Repetitive exposure of mice to strong static magnetic fields in utero does not impair fertility in adulthood but may affect placental weight of offspring. J Magn Reson Imaging 2013; 39:683-90. [DOI: 10.1002/jmri.24208] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2012] [Accepted: 04/12/2013] [Indexed: 12/21/2022] Open
Affiliation(s)
- Gregor Zaun
- Institute of Molecular Biology; University Hospital; University Duisburg-Essen; Germany
| | - Yasmin Zahedi
- Institute of Molecular Biology; University Hospital; University Duisburg-Essen; Germany
| | - Stefan Maderwald
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Germany
| | - Stephan Orzada
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Germany
- Department of Diagnostic and Interventional Radiology and Neuroradiology; University Hospital; University Duisburg-Essen; Germany
| | - Carolin Pütter
- Institute for Medical Informatics; Biometry and Epidemiology, University Hospital; University of Duisburg-Essen; Germany
| | - André Scherag
- Institute for Medical Informatics; Biometry and Epidemiology, University Hospital; University of Duisburg-Essen; Germany
| | - Elke Winterhager
- Institute of Molecular Biology; University Hospital; University Duisburg-Essen; Germany
| | - Mark E. Ladd
- Erwin L. Hahn Institute for Magnetic Resonance Imaging; University Duisburg-Essen; Germany
- Department of Diagnostic and Interventional Radiology and Neuroradiology; University Hospital; University Duisburg-Essen; Germany
| | - Ruth Grümmer
- Institute of Molecular Biology; University Hospital; University Duisburg-Essen; Germany
- Institute for Anatomy; University Hospital; University Duisburg-Essen; Germany
| |
Collapse
|
13
|
MRI-guided vacuum-assisted breast biopsy: comparison with stereotactically guided and ultrasound-guided techniques. Eur Radiol 2013; 24:128-35. [PMID: 23979106 PMCID: PMC3889280 DOI: 10.1007/s00330-013-2989-5] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2013] [Revised: 06/26/2013] [Accepted: 07/09/2013] [Indexed: 11/24/2022]
Abstract
Objectives To analyse the development of MRI-guided vacuum-assisted biopsy (VAB) in Switzerland and to compare the procedure with stereotactically guided and ultrasound-guided VAB. Methods We performed a retrospective analysis of VABs between 2009 and 2011. A total of 9,113 VABs were performed. Of these, 557 were MRI guided. Results MRI-guided VAB showed the highest growth rate (97 %) of all three procedures. The technical success rates for MRI-guided, stereotactically guided and ultrasound-guided VAB were 98.4 % (548/557), 99.1 % (5,904/5,960) and 99.6 % (2,585/2,596), respectively. There were no significant differences (P = 0.12) between the MRI-guided and the stereotactically guided procedures. The technical success rate for ultrasound-guided VAB was significantly higher than that for MRI-guided VAB (P < 0.001). There were no complications using MRI-guided VAB requiring open surgery. The malignancy diagnosis rate for MRI-guided VAB was similar to that for stereotactically guided VAB (P = 0.35). Conclusion MRI-guided VAB is a safe and accurate procedure that provides insight into clinical breast findings. Key points • Three vacuum-assisted breast biopsy (VAB) procedures were compared. • Technical success rates were high for all three VAB procedures. • Medical complications were relatively low using all three VAB procedures. • The use of MRI-guided vacuum-assisted breast biopsy is growing.
Collapse
|
14
|
SUARIS TD, FROUD I, VINNICOMBE SJ. Breast MRI: getting started. IMAGING 2013. [DOI: 10.1259/imaging.20100022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
15
|
Outcome analysis of 9-gauge MRI-guided vacuum-assisted core needle breast biopsies. AJR Am J Roentgenol 2012; 198:292-9. [PMID: 22268171 DOI: 10.2214/ajr.11.7594] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this article is to correlate 9-gauge MRI-guided vacuum-assisted breast biopsy with surgical histologic findings to determine the upgrade rate and to correlate the frequency of MRI-guided vacuum-assisted breast biopsy cancer diagnosis with breast MRI indications and enhancement characteristics of targeted lesions. MATERIALS AND METHODS A database search was performed of all MRI-guided vacuum-assisted breast biopsies performed from January 1, 2005, to September 31, 2010. The breast MRI indications, history, age, risk factors, lesion size, enhancement characteristics, and pathologic diagnoses at MRI-guided vacuum-assisted breast biopsy and at surgery were documented. Fisher exact test and analysis of variance were used for statistical analysis. RESULTS A total of 218 lesions underwent MRI-guided vacuum-assisted breast biopsy in 197 women (mean age, 52 years; range, 28-76 years), of which 85 (39%) had surgical correlation. Of the 218 lesions, 48 (22%) were malignant, 133 (61%) were benign, and 37 (17%) were high risk according to MRI-guided vacuum-assisted breast biopsy. Ten of 85 lesions (12%) were upgraded to malignancy at surgery, with a final malignancy rate of 25%. The frequency of malignancy was significantly higher in patients presenting for diagnostic (50/177 [28%]) versus screening (4/41 [10%]; p < 0.05) evaluation, patients with ipsilateral cancer (22/49 [45%]; p < 0.001), and lesions with washout kinetics (34/103 [33%]; p < 0.05) and was relatively higher in lesions with nonmasslike enhancement (26/76 [34%]; p = 0.07), which represented ductal carcinoma in situ in the majority of cases (17/26 [65%]; p < 0.005). CONCLUSION Patients with ipsilateral cancer who have additional suspicious lesions identified on MRI require careful evaluation and biopsy to exclude additional sites of cancer that may impact surgical management.
Collapse
|
16
|
Ojeda-Fournier H, Mahoney MC. MR-guided breast interventions: Pearls and pitfalls. APPLIED RADIOLOGY 2011. [DOI: 10.37549/ar1848] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
17
|
Baker JA, Lo JY. Breast tomosynthesis: state-of-the-art and review of the literature. Acad Radiol 2011; 18:1298-310. [PMID: 21893296 DOI: 10.1016/j.acra.2011.06.011] [Citation(s) in RCA: 104] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2011] [Revised: 05/07/2011] [Accepted: 06/20/2011] [Indexed: 10/17/2022]
|
18
|
Meeuwis C, Veltman J, van Hall HN, Mus RDM, Boetes C, Barentsz JO, Mann RM. MR-guided breast biopsy at 3T: diagnostic yield of large core needle biopsy compared with vacuum-assisted biopsy. Eur Radiol 2011; 22:341-9. [PMID: 21915606 PMCID: PMC3249028 DOI: 10.1007/s00330-011-2272-6] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2011] [Revised: 07/09/2011] [Accepted: 07/15/2011] [Indexed: 11/24/2022]
Abstract
Objective The purpose of this study was to evaluate two MR-guided biopsy techniques at 3 T, large core needle breast biopsy (LCNB) and vacuum-assisted breast biopsy (VAB) and to compare the diagnostic yield and rate of complications to determine the optimal biopsy technique at 3 T. Methods 55 LCNB and 64 VAB were consecutively performed. Benign biopsy results were verified by retrospective correlation of histology, with pre-interventional, post-interventional MRI studies and follow-up and were classified as representative or non-representative. Time to follow-up was up to 2 years for the considered non-representative benign lesions. Statistical analysis was performed using the Chi-squared test. Results LCNB was technically successful in 100% of patients (55/55) and VAB in 98% of patients (63/64). Histopathological analysis resulted in 45 (82%) benign, 3 (5%) high-risk and 7 (13%) malignant lesions for LCNB and 43 (67%) benign, 3 (5%) high-risk and 18 (28%) malignant lesions. Distribution was significantly different (p < 0.001), favouring VAB over LCNB. Conclusion Because of the substantially higher diagnostic yield and certainty of a benign diagnosis, VAB is the optimal biopsy technique at 3 T. LCNB should be considered when VAB is not feasible.
Collapse
Affiliation(s)
- Carla Meeuwis
- Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein-Zuid 10, 6525GA Nijmegen, the Netherlands.
| | | | | | | | | | | | | |
Collapse
|
19
|
Rendi MH, Dintzis SM, Lehman CD, Calhoun KE, Allison KH. Lobular In-Situ Neoplasia on Breast Core Needle Biopsy: Imaging Indication and Pathologic Extent Can Identify Which Patients Require Excisional Biopsy. Ann Surg Oncol 2011; 19:914-21. [DOI: 10.1245/s10434-011-2034-3] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2011] [Indexed: 11/18/2022]
|
20
|
Fischman AM, Epelboym Y, Siegelbaum RH, Weintraub JL, Kim E, Nowakowski FS, Lookstein RA. Emergent embolization of arterial bleeding after vacuum-assisted breast biopsy. Cardiovasc Intervent Radiol 2011; 35:194-7. [PMID: 21553162 DOI: 10.1007/s00270-011-0174-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/07/2011] [Accepted: 04/18/2011] [Indexed: 11/24/2022]
Abstract
Vacuum-assisted core breast biopsy has become important in evaluating patients with suspicious breast lesions. It has proven to be a relatively safe procedure that in rare cases can result in vascular complications. These are the first reported cases of transcatheter embolization of uncontrolled breast hemorrhage after vacuum-assisted breast biopsy. With increased use of biopsy and larger-gauge devices, breast imaging groups may consider embolotherapy as a safe alternative for treatment of hemorrhage in a select group of patients.
Collapse
Affiliation(s)
- Aaron M Fischman
- Department of Radiology, Mount Sinai School of Medicine, Klingenstein Pavillion Floor MC Level, 1176 Fifth Avenue, New York, NY 10029, USA.
| | | | | | | | | | | | | |
Collapse
|
21
|
Magnetic Resonance Imaging-guided Breast Biopsies: Tips and Tricks. Can Assoc Radiol J 2011; 62:15-21. [DOI: 10.1016/j.carj.2010.09.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2010] [Revised: 08/19/2010] [Accepted: 09/02/2010] [Indexed: 11/20/2022] Open
|
22
|
The impact of imaging speed of MR-guided punctures and interventions in static organs--a phantom study. Eur J Radiol 2011; 80:856-60. [PMID: 21227616 DOI: 10.1016/j.ejrad.2010.12.030] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2010] [Revised: 12/03/2010] [Accepted: 12/15/2010] [Indexed: 01/19/2023]
Abstract
PURPOSE Verification of MR-guidance with image acquisitions slower than 1 image per second as it is inevitable for some interventions. Therefore, we quantified solely the effect of acquisition-time on the efficiency of MR-guided interventions in a static phantom study. MATERIALS AND METHODS We measured the duration, accuracy and error rate of simulated interventions for different acquisition-times using a simplified interventional setup. All measurements were performed in a 1.0 T open MRI scanner. Imaging was performed with a gradient-echo sequence (flipangle=20°; TR/TE=12/6 ms; voxelsize=1 mm×1 mm; slicethickness=5 mm; FOV=230 mm×200 mm; acquisition-time=1 s). Variable acquisition times were simulated with intermediate pauses of 0, 1, 2, 3, 4 and 5 s. The interventions were performed by a total of 20 volunteers including 7 experienced interventionalists. RESULTS The mean duration of the intervention was 2 min. Significant differences between experienced and unexperienced volunteers were limited to the localization of the image plane and corrections made. The mean accuracy was 5.6 mm. The time to localize the image plane increased with deceleration of imaging from 24 s to 49 s. A similar increase was observed for the intervention time (55-108 s). A significant influence of the acquisition-time on durations and corrections was only found with acquisition-times greater than 4s per image. CONCLUSION Even image rates of several seconds per image are sufficient enough for efficient interventions in static organs. Thus, the main attention has to be turned on the visibility of the needle when sequences are optimized for MR-guidance. The minimization of imaging speed is rather of secondary interest.
Collapse
|
23
|
Tomikawa M, Hong J, Shiotani S, Tokunaga E, Konishi K, Ieiri S, Tanoue K, Akahoshi T, Maehara Y, Hashizume M. Real-time 3-dimensional virtual reality navigation system with open MRI for breast-conserving surgery. J Am Coll Surg 2010; 210:927-33. [PMID: 20510801 DOI: 10.1016/j.jamcollsurg.2010.01.032] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2009] [Revised: 01/26/2010] [Accepted: 01/26/2010] [Indexed: 10/19/2022]
Abstract
BACKGROUND The aim of this study was to report on the early experiences using a real-time 3-dimensional (3D) virtual reality navigation system with open MRI for breast-conserving surgery. STUDY DESIGN We developed a real-time 3D virtual reality navigation system with open MRI, and evaluated the mismatch between the navigation system and real distance using a 3D phantom. Two patients with nonpalpable MRI-detected breast tumors underwent breast-conserving surgery under the guidance of the navigation system. An initial MRI for the breast tumor using skin-affixed markers was performed immediately before excision. A percutaneous intramammary dye marker was applied to delineate an excision line, and the computer software "3D Slicer" generated a real-time 3D virtual reality model of the tumor and the puncture needle in the breast. Excision of the tumor was performed in the usual manner along the excision line indicated with the dye. The resected specimens were carefully examined histopathologically. RESULTS The mean mismatch between the navigation system and real distance was 2.01 +/- 0.32 mm when evaluated with the 3D phantom. Under guidance by the navigation system, a percutaneous intramammary dye marker was applied without any difficulty. Fiducial registration errors were 3.00 mm for patient no. 1, and 4.07 mm for patient no. 2. Histopathological examinations of the resected specimens of the 2 patients showed noninvasive ductal carcinoma in situ. The surgical margins were free of carcinoma cells. CONCLUSIONS Real-time 3D virtual reality navigation system with open MRI is feasible for safe and accurate excision of nonpalpable MRI-detected breast tumors. Long-term outcomes of this technique should be evaluated further.
Collapse
Affiliation(s)
- Morimasa Tomikawa
- Department of Future Medicine and Innovative Medical Information, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, Japan.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
24
|
Thayer D, Unlu MB, Lin Y, Yan K, Nalcioglu O, Gulsen G. Dual-contrast dynamic MRI-DOT for small animal imaging. Technol Cancer Res Treat 2010; 9:61-70. [PMID: 20082531 DOI: 10.1177/153303461000900107] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
In this paper we present first-of-its-kind spatially resolved enhancement kinetics of optical and magnetic resonance (MR) agents obtained by a combined MR and Diffuse Optical Tomography (MR-DOT) animal imaging system. A unique MR compatible fiber optic interface allows co-registration of MR and DOT data in space and time. High temporal resolution of the hybrid system permits acquisition of data in dynamic mode. Rats bearing a R3230 AC breast cancer tumor model are used for in vivo studies. Thirty-two optical and thirty MR images are acquired during a single imaging session that lasts nearly ten minutes. Both optical, indocyanine green (ICG), and MR contrast agents, gadolinium-DTPA (Gd-DTPA), are injected simultaneously after the acquisition of several baseline frames. Contrast enhancement time curves obtained by MR and DOT systems both indicate higher average enhancement in tumor regions, up to ten-fold for MRI and 3-fold for DOT, compared to close by non-tumor regions. This feasibility study is the first step towards clinical translation of this hybrid imaging platform. The ultimate aim is to use the enhancement kinetics of the optical agent ICG, which binds to plasma proteins, as complementary information to the kinetics of the MR agent Gd-DTPA, a small molecular agent that does not bind to plasma proteins, to better differentiate benign and malignant lesions.
Collapse
Affiliation(s)
- David Thayer
- Tu and Yuen Center for Functional Onco-Imaging, University of California Irvine, CA 92692, USA
| | | | | | | | | | | |
Collapse
|