1
|
Huang X, Shao X, Li J. One-year outcomes of biological mesh in hiatal hernia repair: a real-world study. Hernia 2025; 29:123. [PMID: 40131543 DOI: 10.1007/s10029-025-03316-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2024] [Accepted: 03/07/2025] [Indexed: 03/27/2025]
Abstract
PURPOSE The placement of synthetic mesh during laparoscopic hiatal hernia repair has been verified to reduce postoperative recurrence, but mesh erosion and other related complications may occur to synthetic mesh, and our aim was to verify the safety and efficacy of biological mesh in hiatal hernia repair. METHODS Patients with hiatal hernia who were treated at a tertiary teaching university hospital from December 2020 to May 2023 were prospectively included in this study. General clinical data, hernia-related data, and intraoperative data were collected, and the patients were followed up at 1, 3, 6, and 12 months after surgery, after 12 months, follow-up as needed for primary outcome until September 2024. The following parameters were recorded during follow-up visit: gastroesophageal reflux symptoms, Gastroesophageal reflux disease-Health related quality of life (GERD-HRQL) questionnaire, postoperative recurrence, mesh-related complications and patients' overall satisfaction. RESULTS A total of 82 patients with hiatal hernia were included in this study. The mean age of the patients was 62.68 ± 15.93 years, mean BMI 24.81 ± 4.05 kg/m2, the average operation time was 128.21 ± 39.20 min. There was statistically significant improvement of GERD symptom postoperative (p<0.05). 72 cases (93.5%) were rated as "Great" on the GERD-HRQL at the 12 months after surgery; 65 cases (84.4%) were rated as "very satisfactory" on the overall satisfaction scale at the 12 months after surgery. 6 patients (7.3%) experienced recurrences, with no mesh-related complications reported during the follow-up. CONCLUSION At a mean follow-up of 25.43 ± 10.38 months, the present study showed that laparoscopic hiatal hernia repair with biologic mesh results in low rates of 1-year recurrence and complications and increased patient satisfaction.
Collapse
Affiliation(s)
- Xianggang Huang
- Department of Hernia and Abdominal wall Surgery, Affiliated Zhongda Hospital, Southeast University, Nanjing, 210009, China
- Department of General Surgery, The Second Affiliated Hospital of Nantong University, Nantong, 226001, China
| | - Xiangyu Shao
- Department of Hernia and Abdominal wall Surgery, Affiliated Zhongda Hospital, Southeast University, Nanjing, 210009, China
| | - Junsheng Li
- Department of Hernia and Abdominal wall Surgery, Affiliated Zhongda Hospital, Southeast University, Nanjing, 210009, China.
| |
Collapse
|
2
|
Patrzyk M, Hummel R, Kersting S. [Surgical strategy for hiatal hernias]. CHIRURGIE (HEIDELBERG, GERMANY) 2024; 95:336-344. [PMID: 38372742 DOI: 10.1007/s00104-024-02054-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 02/02/2024] [Indexed: 02/20/2024]
Abstract
The indications for surgical treatment of hiatus hernias differentiate between type I and types II, III and IV hernias. The indications for a type I hernia should include a proven reflux disease but the indications for surgical treatment of types II, III and IV hernias are mandatory due to the symptoms with problems in the passage of food and due to the sometimes very severe possible complications. The primary aims of surgery are the repositioning of the herniated contents and a hiatoplasty, which includes a surgical narrowing of the esophageal hiatus by suture implantation. In addition, depending on the clinical situation other procedures, such as hernia sac removal, mesh implantation, gastropexy and fundoplication can be considered. There are various approaches to the repair, all of which have individual advantages and disadvantages. An adaptation to the specific needs situation of the patient and the expertise of the surgeon is therefore essential.
Collapse
Affiliation(s)
| | | | - Stephan Kersting
- Klinik für Allgemeine Chirurgie, Viszeral‑, Thorax- und Gefäßchirurgie, Universitätsmedizin Greifswald, Ferdinand-Sauerbruch-Straße, 17475, Greifswald, Deutschland.
| |
Collapse
|
3
|
Geißler B, Birk E, Anthuber M. [Report of 12 years experience in the surgical treatment of 286 paraesophageal hernias]. Chirurg 2015. [PMID: 26223669 DOI: 10.1007/s00104-015-0066-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
BACKGROUND In contrast to axial hiatus hernias, paraesophageal hernias are rare but can lead to chronic iron deficiency anemia and severe acute complications. Treatment is manifold and consistent standards are lacking. OBJECTIVES The aim of this study was to describe our experiences of 286 patients with paraesophageal hernias, who underwent surgery from 2003 to 2014 at a tertiary referral center. The study was particularly concerned with morbidity, mortality, quality of life and recurrence rates. MATERIAL AND METHODS In 12 years a total of 286 paraesophageal hernias were surgically treated, 255 with a minimally invasive procedure and 31 with an open approach. In 138 patients (48 %) the suture-based hiatoplasty was reinforced by means of a lightweight mesh, which was fixed with fibrin glue in 90 cases. Abdominal fixation of the stomach consisted of a gastropexy and anterior (n = 244) or posterior (n = 42) fundoplication. RESULTS Complications arose in 8.4 % of the patients. The mean hospital stay was 5.3 (± 2.8) days for elective surgery and 24.7 (± 17.8) days for emergency operations. The gastrointestinal quality of life index according to Eypasch significantly increased from mean preoperative values of 92.8 (± 22.5) to 109.6 (± 20.2) in the postoperative course (p < 0.001). Of the patients 20 (7 %) suffered a recurrence requiring surgery, including 7 early and 13 late recurrences. During the immediate postoperative period radiographically detected recurrences were promptly revised. The strategy of late recurrences in the long-term course was based on patient symptoms and asymptomatic hernias were treated conservatively while symptomatic hernias were surgically treated. Symptomatic late recurrences developed in 4.6 % of the patients, including 7.4 % (11 out of 148) without and 1.4 % (2 out of 138) with primary mesh repair. CONCLUSION The repair of paraesophageal hernias in 286 patients provided excellent patient satisfaction and symptom improvement with low perioperative morbidity and mortality. Mesh reinforcement reduced the recurrence rate. The quality of life index is a suitable clinical course parameter for evaluation of paraesophageal hernias.
Collapse
Affiliation(s)
- B Geißler
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Klinikum Augsburg, Stenglinstraße 2, 86156, Augsburg, Deutschland.
| | - E Birk
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Klinikum Augsburg, Stenglinstraße 2, 86156, Augsburg, Deutschland
| | - M Anthuber
- Klinik für Allgemein-, Viszeral- und Transplantationschirurgie, Klinikum Augsburg, Stenglinstraße 2, 86156, Augsburg, Deutschland
| |
Collapse
|
4
|
Kohn GP, Price RR, DeMeester SR, Zehetner J, Muensterer OJ, Awad Z, Mittal SK, Richardson WS, Stefanidis D, Fanelli RD. Guidelines for the management of hiatal hernia. Surg Endosc 2013; 27:4409-4428. [PMID: 24018762 DOI: 10.1007/s00464-013-3173-3] [Citation(s) in RCA: 291] [Impact Index Per Article: 24.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2013] [Accepted: 08/02/2013] [Indexed: 02/08/2023]
Affiliation(s)
- Geoffrey Paul Kohn
- Department of Surgery, Eastern Health Clinical School, Monash University, Melbourne, VIC, Australia,
| | | | | | | | | | | | | | | | | | | |
Collapse
|
5
|
Powell BS, Wandrey D, Voeller GR. A technique for placement of a bioabsorbable prosthesis with fibrin glue fixation for reinforcement of the crural closure during hiatal hernia repair. Hernia 2012; 17:81-4. [PMID: 22581201 DOI: 10.1007/s10029-012-0915-4] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2011] [Accepted: 04/22/2012] [Indexed: 01/05/2023]
Abstract
INTRODUCTION Level 1 data suggest that mesh reinforcement of the crural closure for hiatal hernia repair decreases the recurrence of hernia. The fear of erosion of the prosthetic into the esophagus has kept the use of mesh for hiatal hernia repair from becoming routine. A recent study found several cases of esophageal stenosis/erosion from the use of a biologic mesh. For these reasons, we evaluated a new resorptive prosthetic and new method of fixation of the prosthetic for crural reinforcement during hiatal hernia repair. METHODS From February 2009 until December 2010, 70 patients underwent hiatal hernia repair using a synthetic bioabsorbable prosthetic made of polglycolide and teimethylene carbonate (Gore BioA Tissue Reinforcement™, Flagstaff, AZ). There were 48 patients with paraesophageal hiatal hernias and 22 with large sliding hiatal hernias. In this study, a square piece of mesh just the size to cover the crural closure only was utilized. Fibrin glue (Tisseel™) was applied over the suture closure of the crura, the mesh was then placed over the glue and held in place for several seconds, and then more fibrin glue was applied on top of the mesh. RESULTS The new bioabsorbable polymer mesh was readily placed through a 10-mm trocar, had good handling characteristics laparoscopically, and no pre-operative preparation was required of the prosthetic. The material and the fibrin glue created a very substantial reinforcement of the crural closure, and the average time to place and fix the mesh was approximately 5 min. There were no short-term complications from the mesh, and no patient has had any significant post-operative sequelae. CONCLUSION Crural closure reinforcement during hiatal hernia repair can be done readily with this new bioabsorbable polymer-based mesh. Fibrin glue fixation of this new prosthetic can be done quickly and it creates a strong, fixed barrier that may decrease the chance of erosion. Further studies will need to be done to evaluate long-term efficacy and complications associated with its use.
Collapse
Affiliation(s)
- B S Powell
- University of Tennessee Health Science Center at Memphis, Memphis, TN 38104, USA.
| | | | | |
Collapse
|
6
|
Jenkins ED, Lerdsirisopon S, Costello KP, Melman L, Greco SC, Frisella MM, Matthews BD, Deeken CR. Laparoscopic fixation of biologic mesh at the hiatus with fibrin or polyethylene glycol sealant in a porcine model. Surg Endosc 2011; 25:3405-13. [PMID: 21594740 PMCID: PMC3826827 DOI: 10.1007/s00464-011-1741-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2011] [Accepted: 04/15/2011] [Indexed: 01/12/2023]
Abstract
BACKGROUND The objective of this study was to determine the acute and chronic fixation strengths achieved by fibrin or polyethylene glycol (PEG) sealants to secure biologic mesh at the esophageal hiatus in a porcine model. METHODS For this study, 32 female domestic pigs were divided into four groups of 8 each. The four groups respectively received acute fibrin sealant, acute PEG sealant, chronic fibrin sealant, and chronic PEG sealant. Laparoscopically, a 5.5 × 8.5-cm piece of Biodesign Surgisis Hiatal Hernia Graft (porcine small intestine submucosa) was oriented with the U-shaped cutout around the gastroesophageal junction and the short axis in the craniocaudal direction to simulate hiatal reinforcement with a biologic mesh. The mesh then was secured with 2 ml of either fibrin sealant or PEG sealant. The pigs in the acute groups were maintained alive for 2 h to allow for complete polymerization of the sealants, and the pigs in the chronic group were maintained alive for 14 days. After the pigs were euthanized, specimens of the mesh-tissue interface were subjected to lap shear testing to determine fixation strength, and hematoxylin and eosin (H&E) stained slides were evaluated for evidence of remodeling. RESULTS No significant differences were observed between the acute and chronic fixation strengths or the remodeling characteristics of the two sealants. However, fixation strength increased significantly over time for both types of sealant. Evidence of remodeling also was significantly more pronounced in the chronic specimens than in the acute specimens. CONCLUSIONS This study demonstrated the feasibility of using fibrin or PEG sealants to secure biologic mesh at the hiatus in a porcine model.
Collapse
Affiliation(s)
- Eric D. Jenkins
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Sopon Lerdsirisopon
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Kevin P. Costello
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Lora Melman
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Suellen C. Greco
- Division of Comparative Medicine, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis MO 63110, USA
| | - Margaret M. Frisella
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Brent D. Matthews
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| | - Corey R. Deeken
- Department of Surgery, Section of Minimally Invasive Surgery, Washington University School of Medicine, 660 South Euclid Avenue, Campus Box 8109, St. Louis, MO 63110, USA
| |
Collapse
|
7
|
Fixation of mesh to the peritoneum using a fibrin glue: investigations with a biomechanical model and an experimental laparoscopic porcine model. Surg Endosc 2009; 24:1501-2; author reply 1503-4. [PMID: 20033718 DOI: 10.1007/s00464-009-0775-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|