1
|
Xu H, Huang W, Guo Y, Li M, Peng G, Wu T. Efficacy of extended view totally extra peritoneal approach versus laparoscopic intraperitoneal on lay mesh plus for abdominal wall hernias: a single center preliminary retrospective study. BMC Surg 2023; 23:200. [PMID: 37443007 DOI: 10.1186/s12893-023-02098-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2023] [Accepted: 07/05/2023] [Indexed: 07/15/2023] Open
Abstract
BACKGROUND Laparoscopic minimally invasive surgery has become the primary treatment for ventral hernias. The laparoscopic intraperitoneal on lay mesh (IPOM) plus approach for abdominal wall hernias is the most used procedure, while extended view totally extraperitoneal (e‑TEP) repair is a newer option. This study aimed to compare the effectiveness and complications of the 2 procedures for abdominal wall hernias repair. METHODS This was a retrospective and comparative single-center study done at The Second Clinical Medical College, Jinan University Hospital (Shenzhen People's Hospital), Shenzhen, China. The study included patients with a 2 to 6 cm abdominal wall defect who underwent hernia repair from January 2022 to December 2022. Patients' baseline characteristics, hernia features, operative time, blood loss, postoperative pain level, and total hospitalization expenses were extracted from the medical records and compared between patients who underwent the IPOM plus and e-TEP repair. RESULTS A total of 53 patients were included: 22 in the e-TEP group and 31 in IPOM plus group. Patient demographic characteristics were similar between the 2 groups. The operation time of the e-TEP groups was significantly longer than the IPOM plus (98.5 ± 10.7 min vs. 65.9 ± 7.3 min, P < 0.01). Postoperative pain levels (VAS; visual analog scale) (4.2 ± 0.9 vs. 6.7 ± 0.9, P < 0.01), analgesic requirements (Tramadol) (25.0 ± 37.0 mg vs. 72.6 ± 40.5 mg, P < 0.01), length of hospital stay (1.2 ± 0.5days vs. 2.2 ± 0.6days, P < 0.01), and total hospitalization expenses (19695.9 ± 1221.7CNY vs. 35286.2 ± 1196.6CNY, P < 0.01) were significantly lower in the e-TEP group. The mean intraoperative blood loss was similar between the 2 groups. No postoperative complications were observed in either group. CONCLUSION The e-TEP approach for abdominal wall hernias appears to be better than IPOM plus with respect to postoperative pain levels(VAS: 4.2 ± 0.9 vs. 6.7 ± 0.9, P < 0.01), analgesic requirements(25.0 ± 37.0 mg vs. 72.6 ± 40.5 mg, P < 0.01), length of hospital stay(1.2 ± 0.5days vs. 2.2 ± 0.6days, P < 0.01), and hospitalization costs (19695.9 ± 1221.7CNY vs. 35286.2 ± 1196.6CNY, P < 0.01).
Collapse
Affiliation(s)
- Haisong Xu
- The Second Clinical Medical College, Jinan University, Shenzhen, China
| | - Wenhao Huang
- The Second Clinical Medical College, Jinan University, Shenzhen, China
| | - Yuehua Guo
- Department of Hepatobiliary and Pancreatic Surgery, Shenzhen People's Hospital, The Second Clinical Medical College, Jinan University, Shenzhen, 518020, Guangdong Province, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Mingyue Li
- Department of Hepatobiliary and Pancreatic Surgery, Shenzhen People's Hospital, The Second Clinical Medical College, Jinan University, Shenzhen, 518020, Guangdong Province, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Gongze Peng
- Department of Hepatobiliary and Pancreatic Surgery, Shenzhen People's Hospital, The Second Clinical Medical College, Jinan University, Shenzhen, 518020, Guangdong Province, China
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China
| | - Tianchong Wu
- Department of Hepatobiliary and Pancreatic Surgery, Shenzhen People's Hospital, The Second Clinical Medical College, Jinan University, Shenzhen, 518020, Guangdong Province, China.
- The First Affiliated Hospital, Southern University of Science and Technology, Shenzhen, China.
| |
Collapse
|
2
|
Phoa S, Chan KS, Lim SH, Oo AM, Shelat VG. Comparison of glue versus suture mesh fixation for primary open inguinal hernia mesh repair by Lichtenstein technique: a systematic review and meta-analysis. Hernia 2022; 26:1105-1120. [PMID: 35113292 DOI: 10.1007/s10029-022-02571-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 01/13/2022] [Indexed: 02/05/2023]
Abstract
BACKGROUND The use of glue as a mesh fixator in open Lichtenstein inguinal hernia repair (IHR) has gained popularity to reduce recurrence and postoperative complications. This meta-analysis aims to provide an up-to-date review to compare glue versus suture fixation in primary open Lichtenstein IHR. METHODS PubMed, Embase, The Cochrane Library, Web of Science, and Springer were systematically searched till June 2021 for randomized controlled trials (RCTs) comparing glue versus suture fixation in open Lichtenstein IHR. Primary outcomes were early (at 1 year) and late recurrence (5 years or more). Secondary outcomes were the length of operation, postoperative haematoma and seroma, and chronic pain at 1 year. RESULTS A total of 17 RCTs with 3150 hernias (glue n = 1582, suture n = 1568) were included. Only three studies reported late recurrence. Glue fixation was associated with shorter operative duration (MD - 4.17, 95% CI - 4.82, - 3.52; p < 0.001 and a lower incidence of haematoma formation (OR 0.51, 95% CI 0.32, 0.81; p = 0.004). There was no significant difference in postoperative seroma (OR 0.72, 95% CI 0.35, 1.49; p = 0.38), chronic pain after 1 year (OR 1.10, 95% CI 0.73, 1.65; p = 0.65), early recurrence (OR 1.11, 95% CI 0.45, 2.76; p = 0.81, I2 = 0%), and late recurrence (OR 1.23, 95% CI 0.59, 2.59; p = 0.59, I2 = 0%). CONCLUSION Early and late recurrence were comparable between glue and suture fixation in open Lichtenstein IHR patients. Glue fixation had shorter operating time and lower haematoma formation than suture fixation. Chronic pain and seroma formation were comparable. More RCTs should report long-term outcomes.
Collapse
Affiliation(s)
- Shaun Phoa
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore
| | - Kai Siang Chan
- Department of General Surgery, Tan Tock Seng Hospital, Singapore, 308433, Singapore.
| | - Sioh Huang Lim
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore
| | - Aung Myint Oo
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore
- Department of General Surgery, Tan Tock Seng Hospital, Singapore, 308433, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, 308232, Singapore
| | - Vishal G Shelat
- Yong Loo Lin School of Medicine, National University of Singapore, Singapore, 117597, Singapore
- Department of General Surgery, Tan Tock Seng Hospital, Singapore, 308433, Singapore
- Lee Kong Chian School of Medicine, Nanyang Technological University, Singapore, 308232, Singapore
| |
Collapse
|
3
|
Artsen AM, Rytel M, Liang R, King GE, Meyn L, Abramowitch SD, Moalli PA. Mesh induced fibrosis: The protective role of T regulatory cells. Acta Biomater 2019; 96:203-210. [PMID: 31326666 DOI: 10.1016/j.actbio.2019.07.031] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2019] [Revised: 07/15/2019] [Accepted: 07/16/2019] [Indexed: 02/06/2023]
Abstract
Polypropylene mesh is widely used in urogynecologic surgery, but complications rates (pain and exposure) approach 10%. Emerging evidence implicates the adaptive immune system in regulating the foreign body response to mesh, particularly regulatory T cells (Tregs), which modify macrophage differentiation and down-regulate CD8+ effector T cells. We hypothesize that Tregs protect against a profibrotic response, a likely mechanism of pain complications. Here, thin sections of mesh-tissue complexes removed for the primary complaint of pain (N = 14) or exposure (N = 15) were labeled for CD8, CD4 (Th), and FoxP3 (Tregs) via immunofluorescence. The same sections were analyzed for localized collagen deposition via a customized semi-quantitative assessment (0.25 mm2 grid) after trichrome staining. TGF-β1 concentrations were determined by enzyme-linked immunosorbent assay. Fewer Treg and CD4+ cells were found in fibrotic areas versus non-fibrotic areas (503 and 550/cm2 fewer, respectively, both P < 0.001). TGF-β1 was higher in mesh samples compared to autologous control biopsies. TGF-β 1 inversely correlated with age, r -0.636(p = 0.008). No differences were found in T cell subgroups or fibrotic indices between pain and exposure groups. A moderate inverse relationship was found between TGF-β1 and Tregs (r -0.402, P = 0.009). Tregs were present up to 12 years after mesh implantation, challenging the assumption that the adaptive immune response to a foreign body is transient. In conclusion, the inverse relationship between fibrosis and Tregs, and TGF-β1 and Tregs points to a protective role of these cells. Similar immunologic responses in patients with pain and exposure suggest these complications exist along a spectrum. STATEMENT OF SIGNIFICANCE: The use of polypropylene mesh has been associated with improved outcomes in urogynecologic surgery, but is associated with significant complications, including pain and exposure through the vaginal epithelium. The host immune response features a prolonged inflammatory reaction containing innate immune cells and T lymphocytes clustered in capsules around the mesh fibers. This study uncovers the inverse relationship between T regulatory cells and the extent of fibrosis around the mesh, suggesting an anti-fibrotic effect. In addition, concentrations of T regulatory and T effector cells and levels of fibrosis connect these two most common complications into one mechanistic pathway. These new insights into the immune response to implanted mesh are an important step in understanding the causes of these surgical complications.
Collapse
|
4
|
Xiaolong Y, Xiaoyan H, Bo W, Jianglong H, Xiaofeng Y, Xiao T, Zongheng Z, Linbo L, Zefeng Z, Hongbo W. Ventral hernia repair in rat using nanofibrous polylactic acid/polypropylene meshes. Nanomedicine (Lond) 2018; 13:2187-2199. [PMID: 29998792 DOI: 10.2217/nnm-2018-0165] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Abstract
Aim: In the present study, we combined a nanofibrous polylactic acid (PLA) scaffold fabricated by electrospinning with a polypropylene (PP) material to generate a new type of mesh for hernia repair. Materials & methods: The PLA/PP mesh was tested with tensile testing, in vitro cytocompatibility and degradation. A total of 90 rats were randomly allocated to PLA/PP, PP and polyester (PE) mesh groups for the in vivo study to evaluate the properties of PLA/PP mesh. Results: PLA/PP mesh had superior mechanical properties. It also resulted in less inflammation adhesion formation (p < 0.05), which was related to the TGF-β1/Smad pathway. The distribution of collagen I and III in PLA/PP mesh was also superior to those in the other two groups (p < 0.05). Conclusion: The PLA/PP mesh would be suitable for ventral hernia repair in the future.
Collapse
Affiliation(s)
- Ye Xiaolong
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Han Xiaoyan
- Central Laboratory, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Wei Bo
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Huang Jianglong
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Yang Xiaofeng
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Tang Xiao
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Zheng Zongheng
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| | - Luo Linbo
- Medprin Regenerative Medical Technologies Co. Ltd Guangzhou, Guangdong 510630, China
| | - Zhan Zefeng
- Medprin Regenerative Medical Technologies Co. Ltd Guangzhou, Guangdong 510630, China
| | - Wei Hongbo
- Department of Gastrointestinal Surgery, the Third Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong 510630, China
| |
Collapse
|
5
|
Importance of mesh overlap on hernia recurrence after open umbilical hernia repair with bilayer prosthesis. Am J Surg 2018; 216:919-922. [PMID: 29429547 DOI: 10.1016/j.amjsurg.2018.01.041] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Revised: 01/07/2018] [Accepted: 01/13/2018] [Indexed: 11/23/2022]
Abstract
BACKGROUND importance of mesh overlap on recurrence after open umbilical hernia repair has been poorly studied. METHODS a retrospective cohort study was performed with patients who underwent open umbilical hernia repair with bilayer prosthesis between 2004 and 2015. RESULTS 1538 patients were included. Fifty patients (3.3%) had a mesh overlap lower than 1 cm. After a mean follow-up of 4.1 years 53 patients (3.5%) developed a recurrence. Recurrence was associated with a mesh overlap smaller than 1 cm (10.2% vs. 3.3%, p = 0.010, OR = 3.3). In the logistic regression model an overlap smaller than 1 cm was not statistically associated with recurrence (OR = 2.5, p = 0.123). Female gender, postoperative complications and prosthesis size were associated with hernia recurrence. CONCLUSIONS mesh overlap seems to be an important factor for hernia recurrence. A mesh overlap of at least 1 cm should be used until more studies are performed about this issue.
Collapse
|
6
|
Abstract
INTRODUCTION Worldwide, more than 20 million patients undergo groin hernia repair annually. The many different approaches, treatment indications and a significant array of techniques for groin hernia repair warrant guidelines to standardize care, minimize complications, and improve results. The main goal of these guidelines is to improve patient outcomes, specifically to decrease recurrence rates and reduce chronic pain, the most frequent problems following groin hernia repair. They have been endorsed by all five continental hernia societies, the International Endo Hernia Society and the European Association for Endoscopic Surgery. METHODS An expert group of international surgeons (the HerniaSurge Group) and one anesthesiologist pain expert was formed. The group consisted of members from all continents with specific experience in hernia-related research. Care was taken to include surgeons who perform different types of repair and had preferably performed research on groin hernia surgery. During the Group's first meeting, evidence-based medicine (EBM) training occurred and 166 key questions (KQ) were formulated. EBM rules were followed in complete literature searches (including a complete search by The Dutch Cochrane database) to January 1, 2015 and to July 1, 2015 for level 1 publications. The articles were scored by teams of two or three according to Oxford, SIGN and Grade methodologies. During five 2-day meetings, results were discussed with the working group members leading to 136 statements and 88 recommendations. Recommendations were graded as "strong" (recommendations) or "weak" (suggestions) and by consensus in some cases upgraded. In the Results and summary section below, the term "should" refers to a recommendation. The AGREE II instrument was used to validate the guidelines. An external review was performed by three international experts. They recommended the guidelines with high scores. The risk factors for inguinal hernia (IH) include: family history, previous contra-lateral hernia, male gender, age, abnormal collagen metabolism, prostatectomy, and low body mass index. Peri-operative risk factors for recurrence include poor surgical techniques, low surgical volumes, surgical inexperience and local anesthesia. These should be considered when treating IH patients. IH diagnosis can be confirmed by physical examination alone in the vast majority of patients with appropriate signs and symptoms. Rarely, ultrasound is necessary. Less commonly still, a dynamic MRI or CT scan or herniography may be needed. The EHS classification system is suggested to stratify IH patients for tailored treatment, research and audit. Symptomatic groin hernias should be treated surgically. Asymptomatic or minimally symptomatic male IH patients may be managed with "watchful waiting" since their risk of hernia-related emergencies is low. The majority of these individuals will eventually require surgery; therefore, surgical risks and the watchful waiting strategy should be discussed with patients. Surgical treatment should be tailored to the surgeon's expertise, patient- and hernia-related characteristics and local/national resources. Furthermore, patient health-related, life style and social factors should all influence the shared decision-making process leading up to hernia management. Mesh repair is recommended as first choice, either by an open procedure or a laparo-endoscopic repair technique. One standard repair technique for all groin hernias does not exist. It is recommended that surgeons/surgical services provide both anterior and posterior approach options. Lichtenstein and laparo-endoscopic repair are best evaluated. Many other techniques need further evaluation. Provided that resources and expertise are available, laparo-endoscopic techniques have faster recovery times, lower chronic pain risk and are cost effective. There is discussion concerning laparo-endoscopic management of potential bilateral hernias (occult hernia issue). After patient consent, during TAPP, the contra-lateral side should be inspected. This is not suggested during unilateral TEP repair. After appropriate discussions with patients concerning results tissue repair (first choice is the Shouldice technique) can be offered. Day surgery is recommended for the majority of groin hernia repair provided aftercare is organized. Surgeons should be aware of the intrinsic characteristics of the meshes they use. Use of so-called low-weight mesh may have slight short-term benefits like reduced postoperative pain and shorter convalescence, but are not associated with better longer-term outcomes like recurrence and chronic pain. Mesh selection on weight alone is not recommended. The incidence of erosion seems higher with plug versus flat mesh. It is suggested not to use plug repair techniques. The use of other implants to replace the standard flat mesh in the Lichtenstein technique is currently not recommended. In almost all cases, mesh fixation in TEP is unnecessary. In both TEP and TAPP it is recommended to fix mesh in M3 hernias (large medial) to reduce recurrence risk. Antibiotic prophylaxis in average-risk patients in low-risk environments is not recommended in open surgery. In laparo-endoscopic repair it is never recommended. Local anesthesia in open repair has many advantages, and its use is recommended provided the surgeon is experienced in this technique. General anesthesia is suggested over regional in patients aged 65 and older as it might be associated with fewer complications like myocardial infarction, pneumonia and thromboembolism. Perioperative field blocks and/or subfascial/subcutaneous infiltrations are recommended in all cases of open repair. Patients are recommended to resume normal activities without restrictions as soon as they feel comfortable. Provided expertise is available, it is suggested that women with groin hernias undergo laparo-endoscopic repair in order to decrease the risk of chronic pain and avoid missing a femoral hernia. Watchful waiting is suggested in pregnant women as groin swelling most often consists of self-limited round ligament varicosities. Timely mesh repair by a laparo-endoscopic approach is suggested for femoral hernias provided expertise is available. All complications of groin hernia management are discussed in an extensive chapter on the topic. Overall, the incidence of clinically significant chronic pain is in the 10-12% range, decreasing over time. Debilitating chronic pain affecting normal daily activities or work ranges from 0.5 to 6%. Chronic postoperative inguinal pain (CPIP) is defined as bothersome moderate pain impacting daily activities lasting at least 3 months postoperatively and decreasing over time. CPIP risk factors include: young age, female gender, high preoperative pain, early high postoperative pain, recurrent hernia and open repair. For CPIP the focus should be on nerve recognition in open surgery and, in selected cases, prophylactic pragmatic nerve resection (planned resection is not suggested). It is suggested that CPIP management be performed by multi-disciplinary teams. It is also suggested that CPIP be managed by a combination of pharmacological and interventional measures and, if this is unsuccessful, followed by, in selected cases (triple) neurectomy and (in selected cases) mesh removal. For recurrent hernia after anterior repair, posterior repair is recommended. If recurrence occurs after a posterior repair, an anterior repair is recommended. After a failed anterior and posterior approach, management by a specialist hernia surgeon is recommended. Risk factors for hernia incarceration/strangulation include: female gender, femoral hernia and a history of hospitalization related to groin hernia. It is suggested that treatment of emergencies be tailored according to patient- and hernia-related factors, local expertise and resources. Learning curves vary between different techniques. Probably about 100 supervised laparo-endoscopic repairs are needed to achieve the same results as open mesh surgery like Lichtenstein. It is suggested that case load per surgeon is more important than center volume. It is recommended that minimum requirements be developed to certify individuals as expert hernia surgeon. The same is true for the designation "Hernia Center". From a cost-effectiveness perspective, day-case laparoscopic IH repair with minimal use of disposables is recommended. The development and implementation of national groin hernia registries in every country (or region, in the case of small country populations) is suggested. They should include patient follow-up data and account for local healthcare structures. A dissemination and implementation plan of the guidelines will be developed by global (HerniaSurge), regional (international societies) and local (national chapters) initiatives through internet websites, social media and smartphone apps. An overarching plan to improve access to safe IH surgery in low-resource settings (LRSs) is needed. It is suggested that this plan contains simple guidelines and a sustainability strategy, independent of international aid. It is suggested that in LRSs the focus be on performing high-volume Lichtenstein repair under local anesthesia using low-cost mesh. Three chapters discuss future research, guidelines for general practitioners and guidelines for patients. CONCLUSIONS The HerniaSurge Group has developed these extensive and inclusive guidelines for the management of adult groin hernia patients. It is hoped that they will lead to better outcomes for groin hernia patients wherever they live. More knowledge, better training, national audit and specialization in groin hernia management will standardize care for these patients, lead to more effective and efficient healthcare and provide direction for future research.
Collapse
|
7
|
|
8
|
Yang GPC. From intraperitoneal onlay mesh repair to preperitoneal onlay mesh repair. Asian J Endosc Surg 2017; 10:119-127. [PMID: 28547932 DOI: 10.1111/ases.12388] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/09/2017] [Accepted: 04/12/2017] [Indexed: 11/30/2022]
Abstract
Laparoscopic repair for ventral and incisional hernias was first reported in the early 1990s. It uses intraperitoneal only mesh placement to achieve a tension-free repair of the hernia. However, in recent years, there has been greater concern about long-term complication involving intraperitoneal mesh placement. Many case reports and case series have found evidence of mesh adhesion, mesh fistulation, and mesh migration into hollow organs including the esophagus, small bowel, and large bowel, resulting in various major acute abdominal events. Subsequent management of these complications may require major surgery that is technically demanding and difficult; in such cases, laparotomy and bowel resection have often been performed. Because of these significant, but not common, adverse events, many surgeons favor open sublay repair for ventral and incisional hernias. Investigators are therefore searching for a laparoscopic approach for ventral and incisional hernias that might overcome the mesh-induced visceral complications seen after intraperitoneal only mesh placement repair. Laparoscopic preperitoneal onlay mesh is one such approach. This article will explore the fundamental of intraperitoneal only mesh placement and its problems, the currently available peritoneal visceral-compatible meshes, and upcoming developments in laparoscopic ventral and incisional hernia repair. The technical details of preperitoneal onlay mesh, as well as its potential advantages and disadvantages, will also be discussed.
Collapse
|
9
|
Large pore size and controlled mesh elongation are relevant predictors for mesh integration quality and low shrinkage – Systematic analysis of key parameters of meshes in a novel minipig hernia model. Int J Surg 2015; 22:46-53. [DOI: 10.1016/j.ijsu.2015.07.717] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/23/2015] [Accepted: 07/22/2015] [Indexed: 11/18/2022]
|
10
|
Antoniou SA, Köhler G, Antoniou GA, Muysoms FE, Pointner R, Granderath FA. Meta-analysis of randomized trials comparing nonpenetrating vs mechanical mesh fixation in laparoscopic inguinal hernia repair. Am J Surg 2015; 211:239-249.e2. [PMID: 26316363 DOI: 10.1016/j.amjsurg.2015.06.008] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2015] [Revised: 06/11/2015] [Accepted: 06/29/2015] [Indexed: 12/19/2022]
Abstract
BACKGROUND Evidence for open groin hernia repair demonstrates less pain with bioglue mesh fixation compared with invasive methods. This study aimed to assess the short- and long-term effects of laparoscopic groin hernia repair with noninvasive and invasive mesh fixation. DATA SOURCES A systematic review of MEDLINE, CENTRAL, and OpenGrey was undertaken. Randomized trials assessing the outcome of laparoscopic groin hernia repair with invasive and noninvasive fixation methods were considered for data synthesis. Nine trials encompassing 1,454 patients subjected to laparoscopic hernia repair with mesh fixation using biologic or biosynthetic glue were identified. Short-term data were inadequate for data synthesis. Chronic pain was less frequently reported by patients subjected to repair with biologic glue fixation than with penetrating methods (odds ratio .46, 95% confidence interval .22 to .93). Duration of surgery, incidence of seroma/hematoma, morbidity, and recurrence were similar. CONCLUSIONS Laparoscopic groin hernia repair with bioglue mesh fixation was associated with a reduced incidence of chronic pain compared with mechanical fixation, without increasing morbidity or recurrence. Longer term data on recurrence are necessary.
Collapse
Affiliation(s)
- Stavros A Antoniou
- Department of General and Visceral Surgery, Center for Minimally Invasive Surgery, Hospital Neuwerk, Mönchengladbach, Germany; Department of General Surgery, University Hospital of Heraklion, Crete, Greece.
| | - Gernot Köhler
- Department of General Surgery, Sisters of Charity Hospital, Linz, Austria
| | - George A Antoniou
- Liverpool Vascular and Endovascular Service, Royal Liverpool University Hospital, Liverpool, UK
| | | | - Rudolph Pointner
- Department of General Surgery, Hospital Zell am See, Zell am See, Austria
| | - Frank-Alexander Granderath
- Department of General and Visceral Surgery, Center for Minimally Invasive Surgery, Hospital Neuwerk, Mönchengladbach, Germany
| |
Collapse
|
11
|
Danford JM, Osborn DJ, Reynolds WS, Biller DH, Dmochowski RR. Postoperative pain outcomes after transvaginal mesh revision. Int Urogynecol J 2015; 26:65-9. [PMID: 25011703 PMCID: PMC4753795 DOI: 10.1007/s00192-014-2455-1] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2014] [Accepted: 06/14/2014] [Indexed: 10/25/2022]
Abstract
INTRODUCTION AND HYPOTHESIS Although the current literature discusses mesh complications including pain, as well as suggesting different techniques for removing mesh, there is little literature regarding pain outcomes after surgical removal or revision. The purpose of this study is to determine if surgical removal or revision of vaginal mesh improves patient's subjective complaints of pelvic pain associated with original placement of mesh. METHODS After obtaining approval from the Vanderbilt University Medical Center Institutional Review Board, a retrospective review of female patients with pain secondary to previous mesh placement who underwent excision or revision of vaginal mesh from January 2000 to August 2012 was performed. Patient age, relevant medical history including menopause status, previous hysterectomy, smoking status, and presence of diabetes, fibromyalgia, interstitial cystitis, and chronic pelvic pain, was obtained. Patients' postoperative pain complaints were assessed. RESULTS Of the 481 patients who underwent surgery for mesh revision, removal or urethrolysis, 233 patients met our inclusion criteria. One hundred and sixty-nine patients (73 %) reported that their pain improved, 19 (8 %) reported that their pain worsened, and 45 (19 %) reported that their pain remained unchanged after surgery. Prior history of chronic pelvic pain was associated with increased risk of failure of the procedure to relieve pain (OR 0.28, 95 % CI 0.12-0.64, p = 0.003). CONCLUSIONS Excision or revision of vaginal mesh appears to be effective in improving patients' pain symptoms most of the time. Patients with a history of chronic pelvic pain are at an increased risk of no improvement or of worsening pain.
Collapse
Affiliation(s)
- Jill M Danford
- Department of Obstetrics and Gynecology, Vanderbilt University Medical Center, Nashville, TN, USA,
| | | | | | | | | |
Collapse
|