1
|
Fang Y, Ambagtsheer G, Xia L, Clahsen-van Groningen MC, Minnee RC, de Bruin RW. Physiological arterial pressure improves renal performance during normothermic machine perfusion in a porcine kidney DCD model. Heliyon 2025; 11:e41610. [PMID: 39877618 PMCID: PMC11773052 DOI: 10.1016/j.heliyon.2024.e41610] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2024] [Revised: 12/13/2024] [Accepted: 12/30/2024] [Indexed: 01/31/2025] Open
Abstract
Background Normothermic machine perfusion (NMP) provides a platform for kidney quality assessment. Donation after circulatory death (DCD) donor kidneys are associated with great ischemic injury and high intrarenal resistance (IRR). This experimental study aims to investigate the impact of different perfusion pressures on marginal kidney function and injury during NMP. Methods Twenty-seven slaughterhouse porcine kidneys were retrieved and subjected to 60 min of warm ischemia time to mimic DCD condition. These kidneys were randomized into 75 mmHg (subphysiological, n = 9), 95 mmHg (physiological, n = 9), and 115 mmHg NMP (high physiological, n = 9). Renal function and injury were assessed during NMP. Results Three groups showed comparable IRR, with the 115 mmHg group exhibiting the highest blood flow. The 95 mmHg group [0.48 (0.36-1.15) ml/min/100g] and 115 mmHg group [0.93 (0.45-1.41) ml/min/100g] showed significantly higher creatinine clearance compared to the 75 mmHg group [0.16 (0.08-0.37) ml/min/100g] during the first hour of NMP (p = 0.049, p = 0.009, respectively). The 115 mmHg group exhibited significantly higher oxygen consumption compared to the 75 mmHg group at 30 min of NMP [1.37 (1.05-1.92) versus 0.72 (0.61-0.82) mlO2/min/100g, p = 0.009]. Perfusate neutrophil gelatinase-associated lipocalin (NGAL) levels were consistently lowest in the 95 mmHg group and highest in the 75 mmHg group. Aspartate aminotransferase (AST) levels of the 115 mmHg group were significantly higher than the 75 mmHg group. Conclusions For kidneys with high IRR, both 95 mmHg and 115 mmHg perfusion pressures enable an early improvement in renal hemodynamics and function compared to 75 mmHg during NMP, while a high physiological perfusion can cause additional injury.
Collapse
Affiliation(s)
- Yitian Fang
- Division of HPB and Transplant Surgery, Department of Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Gisela Ambagtsheer
- Division of HPB and Transplant Surgery, Department of Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Lin Xia
- Department of Ophthalmology, First Affiliated Hospital of Anhui Medical University, Hefei, China
| | - Marian C. Clahsen-van Groningen
- Department of Pathology and Clinical Bioinformatics, Erasmus Medical Center, Rotterdam, the Netherlands
- Institute of Experimental and Systems Biology, RWTH Aachen University, Aachen, Germany
| | - Robert C. Minnee
- Division of HPB and Transplant Surgery, Department of Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Ron W.F. de Bruin
- Division of HPB and Transplant Surgery, Department of Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
2
|
Lantinga VA, Arykbaeva AS, Spraakman NA, Blom EWP, Huijink TM, de Vries DK, Ploeg RJ, Alwayn IPJ, Leuvenink HGD, Moers C, van Leeuwen LL. Impact of device variability and protocol differences on kidney function during normothermic machine perfusion: A comparative study using porcine and human kidneys. Artif Organs 2025; 49:93-107. [PMID: 39193869 PMCID: PMC11687212 DOI: 10.1111/aor.14851] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2024] [Revised: 07/21/2024] [Accepted: 08/12/2024] [Indexed: 08/29/2024]
Abstract
INTRODUCTION A growing interest in renal normothermic machine perfusion (NMP) has resulted in more clinically available perfusion devices. While all perfusion systems have the same aim, there are significant differences in their circuits, pumps, sensors, and software. Therefore, our objective was to assess the impact of different perfusion protocols and devices on kidney function and perfusion parameters during NMP. METHODS Porcine kidneys were subjected to 30 min of warm ischemia, 24 h of static cold storage, and subsequently perfused for 6 h using (1) the Kidney Assist (KA) machine with a pressure of 75 mm Hg, (2) the KA device incorporating several adjustments and a pressure of 85 mm Hg (modified KA), or (3) the Perlife (PL) perfusion device (n = 4). Consecutively, discarded human kidneys were perfused using the KA or modified KA (n = 3) protocol. RESULTS The PL group quickly reached the device's upper flow limit and consequently received a significantly lower pressure compared to the KA groups. The arterial pO2 was significantly lower in the PL group. Yet, hemoglobin concentration increased over time, and oxygen consumption was significantly higher compared to the KA groups. Fractional sodium excretion was significantly lower in the PL group. Tissue ATP levels, urine production, and creatinine clearance rates did not differ between groups. In human kidneys, the modified KA group showed significantly lower vascular resistance, higher oxygen delivery, and lower levels of lactate in the perfusate compared to the KA group. CONCLUSIONS This study shows that perfusion characteristics and kidney function are significantly influenced by the perfusion protocol and the device and its settings during normothermic machine perfusion and therefore should be interpreted with caution.
Collapse
Affiliation(s)
- Veerle A. Lantinga
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Asel S. Arykbaeva
- Department of SurgeryLeiden University Medical CenterLeidenthe Netherlands
| | - Nora A. Spraakman
- Department of Anaesthesiology, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Elwin W. P. Blom
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Tobias M. Huijink
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Dorottya K. de Vries
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Rutger J. Ploeg
- Department of SurgeryLeiden University Medical CenterLeidenthe Netherlands
- Nuffield Department of Surgical SciencesUniversity of OxfordOxfordUK
| | - Ian P. J. Alwayn
- Department of SurgeryLeiden University Medical CenterLeidenthe Netherlands
| | - Henri G. D. Leuvenink
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - Cyril Moers
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
| | - L. Leonie van Leeuwen
- Department of Surgery, University Medical Center GroningenUniversity of GroningenGroningenthe Netherlands
- Recanati/Miller Transplantation InstituteIcahn School of Medicine at Mount SinaiNew York CityNew YorkUSA
| |
Collapse
|
3
|
Steinhauser C, Yakac A, Markgraf W, Kromnik S, Döcke A, Talhofer P, Thiele C, Malberg H, Sommer U, Baretton GB, Füssel S, Thomas C, Putz J. Assessing Biomarkers of Porcine Kidneys under Normothermic Machine Perfusion-Can We Gain Insight into a Marginal Organ? Int J Mol Sci 2024; 25:10280. [PMID: 39408610 PMCID: PMC11476884 DOI: 10.3390/ijms251910280] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2024] [Revised: 09/17/2024] [Accepted: 09/20/2024] [Indexed: 10/20/2024] Open
Abstract
To identify potentially transplantable organs in a pool of marginal kidneys, 33 porcine slaughterhouse kidneys were perfused for 4 h with whole blood. During the normothermic perfusion, plasma, urine, and tissue samples were taken. Several biomarkers for tubule injury, endothelial activation, and inflammatory response were evaluated for a potential correlation with macroscopic appearance, histology, and filtration activity. Generally, biomarker levels increased during perfusion. TLR-4, EDN-1, and NGAL were not associated with any classification. In contrast, a steeper increase in NAG and IL-6 in plasma correlated with a poor macroscopic appearance at 4 h, indicating a higher inflammatory response in the kidneys with worse macroscopy early on, potentially due to more damage at the tubules. Although long-term effects on the graft could not be assessed in this setting, early observation under machine perfusion with whole blood was feasible. It allowed the assessment of kidneys under conditions comparable to reperfusion. This setting could give surgeons further insight into the quality of marginal kidneys and an opportunity to pre-treat them.
Collapse
Affiliation(s)
- Carla Steinhauser
- Department of Urology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Abdulbaki Yakac
- Department of Urology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Wenke Markgraf
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Susanne Kromnik
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Andreas Döcke
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Philipp Talhofer
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Christine Thiele
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Hagen Malberg
- Institute of Biomedical Engineering, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Ulrich Sommer
- Institute of Pathology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Gustavo B. Baretton
- Institute of Pathology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Susanne Füssel
- Department of Urology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Christian Thomas
- Department of Urology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| | - Juliane Putz
- Department of Urology, Faculty of Medicine, University Hospital Carl Gustav Carus, Technische Universität Dresden, D-01309 Dresden, Germany
| |
Collapse
|
4
|
van Furth LA, Huijink TM, van Leeuwen LL, Maassen H, Lantinga VA, Ogurlu B, Hamelink TL, Pool MBF, Schutter R, Veldhuis SZJ, Ottens PJ, Moers C, Berger SP, Leuvenink HGD, Posma RA, Venema LH. The association between hemoglobin levels and renal function parameters during normothermic machine perfusion: A retrospective cohort study using porcine kidneys. Artif Organs 2024; 48:862-875. [PMID: 38546373 DOI: 10.1111/aor.14750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2023] [Revised: 03/07/2024] [Accepted: 03/13/2024] [Indexed: 07/23/2024]
Abstract
BACKGROUND Ex vivo normothermic machine perfusion (NMP) is a promising tool for assessing an isolated kidney prior to transplantation. However, there is no consensus on the perfusate's optimal oxygen-carrying capacity to support renal function. To investigate the association of hemoglobin levels with renal function parameters, a retrospective analysis of isolated, normothermically, perfused porcine kidneys was performed. METHODS Between 2015 and 2021, a total of 228 kidneys underwent 4 h of NMP with perfusates that varied in hemoglobin levels. A generalized linear model was used to determine the association of hemoglobin levels with time-weighted means of renal function markers, such as fractional sodium excretion (FENa) and creatinine clearance (CrCl). Stratified by baseline hemoglobin level (<4.5, 4.5-6, or >6 mmol/L), these markers were modeled over time using a generalized linear mixed-effects model. All models were adjusted for potential confounders. RESULTS Until a hemoglobin level of around 5 mmol/L was reached, increasing hemoglobin levels were associated with superior FENa and CrCl. Thereafter, this association plateaued. When hemoglobin levels were categorized, hemoglobin <4.5 mmol/L was associated with worse renal function. Hemoglobin levels were neither significantly associated with proteinuria during NMP nor with ATP levels at the end of NMP. Hemoglobin levels >6 mmol/L showed no additional benefits in renal function. CONCLUSION In conclusion, we found an association between baseline hemoglobin levels and superior renal function parameters, but not injury, during NMP of porcine kidneys. Furthermore, we show that performing a retrospective cohort study of preclinical data is feasible and able to answer additional questions, reducing the potential use of laboratory animals.
Collapse
Affiliation(s)
- L Annick van Furth
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Tobias M Huijink
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - L Leonie van Leeuwen
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
- Recanati/Miller Transplantation Institute, Mt. Sinai, New York City, New York, USA
| | - Hanno Maassen
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Veerle A Lantinga
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Baran Ogurlu
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Tim L Hamelink
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Merel B F Pool
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Rianne Schutter
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Susanne Z J Veldhuis
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Petra J Ottens
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Cyril Moers
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Stefan P Berger
- Department of Nephrology, University Medical Center Groningen, Groningen, The Netherlands
| | - Henri G D Leuvenink
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| | - Rene A Posma
- Department of Critical Care, University Medical Center Groningen, Groningen, The Netherlands
| | - Leonie H Venema
- Department of Surgery, University Medical Center Groningen, Groningen, The Netherlands
| |
Collapse
|
5
|
Spencer BL, Wilhelm SK, Urrea KA, Chakrabortty V, Sewera S, Mazur DE, Niman JB, Bartlett RH, Rojas-Peña A, Drake DH. Twenty-four-hour Normothermic Ex Vivo Heart Perfusion With Low Flow Functional Assessment in an Adult Porcine Model. Transplantation 2024; 108:1350-1356. [PMID: 38411562 DOI: 10.1097/tp.0000000000004956] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/28/2024]
Abstract
BACKGROUND Cold static storage and normothermic ex vivo heart perfusion are routinely limited to 6 h. This report describes intermittent left atrial (LA) perfusion that allows cardiac functional assessment in a working heart mode. METHODS Using our adult porcine model, general anesthesia was induced and a complete cardiectomy was performed following cardioplegic arrest. Back-table instrumentation was completed and normothermic ex vivo heart perfusion (NEHP) was initiated in a nonworking heart mode (Langendorff). After 1 h of resuscitation and recovery, LA perfusion was initiated and the heart was transitioned to a coronary flow-only working heart mode for 30 min. Baseline working heart parameters were documented and the heart was returned to nonworking mode. Working heart assessments were performed for 30 min every 6 h for 24 h. RESULTS Twenty-four-hour NEHP on 9 consecutive hearts (280 ± 42.1 g) was successful and no significant differences were found between working heart parameters at baseline and after 24 h of perfusion. There was no difference between initial and final measurements of LA mean pressures (5.0 ± 3.1 versus 9.0 ± 6.5 mm Hg, P = 0.22), left ventricular systolic pressures (44.3 ± 7.2 versus 39.1 ± 9.0 mm Hg, P = 0.13), mean aortic pressures (30.9 ± 5.8 versus 28.1 ± 8.1 mm Hg, P = 0.37), and coronary resistance (0.174 ± 0.046 versus 0.173 ± 0.066 mL/min/g, P = 0.90). There were also no significant differences between lactate (2.4 ± 0.5 versus 2.6 ± 0.4 mmol/L, P = 0.17) and glucose (173 ± 75 versus 156 ± 70 mg/dL, P = 0.37). CONCLUSIONS A novel model using intermittent LA perfusion to create a coronary flow-only working heart mode for assessment of ex vivo cardiac function has been successfully developed.
Collapse
Affiliation(s)
- Brianna L Spencer
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Spencer K Wilhelm
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Kristopher A Urrea
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Vikramjit Chakrabortty
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Sebastian Sewera
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | | | - Joseph B Niman
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Robert H Bartlett
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
| | - Alvaro Rojas-Peña
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
- Department of Surgery, Section of Transplantation, University of Michigan, Ann Arbor, MI
| | - Daniel H Drake
- Department of Surgery and ECLS Laboratory, University of Michigan Medical School, Ann Arbor, MI
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, MI
| |
Collapse
|
6
|
Nikolaev AV, Fang Y, Essers J, Panth KM, Ambagtsheer G, Clahsen-van Groningen MC, Minnee RC, van Soest G, de Bruin RW. Pre-transplant kidney quality evaluation using photoacoustic imaging during normothermic machine perfusion. PHOTOACOUSTICS 2024; 36:100596. [PMID: 38379853 PMCID: PMC10877941 DOI: 10.1016/j.pacs.2024.100596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2023] [Revised: 02/03/2024] [Accepted: 02/08/2024] [Indexed: 02/22/2024]
Abstract
Due to the shortage of kidneys donated for transplantation, surgeons are forced to use the organs with an elevated risk of poor function or even failure. Although the existing methods for pre-transplant quality evaluation have been validated over decades in population cohort studies across the world, new methods are needed as long as delayed graft function or failure in a kidney transplant occurs. In this study, we explored the potential of utilizing photoacoustic (PA) imaging during normothermic machine perfusion (NMP) as a means of evaluating kidney quality. We closely monitored twenty-two porcine kidneys using 3D PA imaging during a two-hour NMP session. Based on biochemical analyses of perfusate and produced urine, the kidneys were categorized into 'non-functional' and 'functional' groups. Our primary focus was to quantify oxygenation (sO2) within the kidney cortical layer of depths 2 mm, 4 mm, and 6 mm using two-wavelength PA imaging. Next, receiver operating characteristic (ROC) analysis was performed to determine an optimal cortical layer depth and time point for the quantification of sO2 to discriminate between functional and non-functional organs. Finally, for each depth, we assessed the correlation between sO2 and creatinine clearance (CrCl), oxygen consumption (VO2), and renal blood flow (RBF). We found that hypoxia of the renal cortex is associated with poor renal function. In addition, the determination of sO2 within the 2 mm depth of the renal cortex after 30 min of NMP effectively distinguishes between functional and non-functional kidneys. The non-functional kidneys can be detected with the sensitivity and specificity of 80% and 85% respectively, using the cut-off point of sO2 < 39%. Oxygenation significantly correlates with RBF and VO2 in all kidneys. In functional kidneys, sO2 correlated with CrCl, which is not the case for non-functional kidneys. We conclude that the presented technique has a high potential for supporting organ selection for kidney transplantation.
Collapse
Affiliation(s)
- Anton V. Nikolaev
- Erasmus MC, Cardiovascular Institute, Thorax Center, Department of Cardiology, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Yitian Fang
- Erasmus MC Transplant Institute, Department of Surgery, Division of HPB and Transplant Surgery, Erasmus Medical Center, Rotterdam, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Jeroen Essers
- Department of Molecular Genetics, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
- Department of Radiotherapy, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
- Department of Vascular Surgery, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Kranthi M. Panth
- Department of Molecular Genetics, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Gisela Ambagtsheer
- Erasmus MC Transplant Institute, Department of Surgery, Division of HPB and Transplant Surgery, Erasmus Medical Center, Rotterdam, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Marian C. Clahsen-van Groningen
- Department of Pathology and Clinical Bioinformatics, Erasmus Medical Center, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Robert C. Minnee
- Erasmus MC Transplant Institute, Department of Surgery, Division of HPB and Transplant Surgery, Erasmus Medical Center, Rotterdam, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| | - Gijs van Soest
- Erasmus MC, Cardiovascular Institute, Thorax Center, Department of Cardiology, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
- Department of Precision and Microsystems Engineering, Faculty of Mechanical Engineering, Delft University of Technology, Van Mourilk Broekmanweg 6, 2628 XE, Delft, the Netherlands
- Wellman Center for Photomedicine, Massachusetts General Hospital, 40 Blossom Street, Boston, MA 02114, USA
| | - Ron W.F. de Bruin
- Erasmus MC Transplant Institute, Department of Surgery, Division of HPB and Transplant Surgery, Erasmus Medical Center, Rotterdam, Dr. Molewaterplein 40, 3015 GD, Rotterdam, the Netherlands
| |
Collapse
|
7
|
Longchamp A, Fontan FM, Aburawi MM, Eymard C, Karimian N, Detelich D, Pendexter C, Cronin S, Agius T, Nagpal S, Banik PD, Tessier SN, Ozer S, Delmonico FL, Uygun K, Yeh H, Markmann JF. Acellular Perfusate is an Adequate Alternative to Packed Red Blood Cells During Normothermic Human Kidney Perfusion. Transplant Direct 2024; 10:e1609. [PMID: 38481967 PMCID: PMC10936975 DOI: 10.1097/txd.0000000000001609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/22/2023] [Revised: 12/26/2023] [Accepted: 01/06/2024] [Indexed: 03/17/2024] Open
Abstract
Background Brief normothermic machine perfusion is increasingly used to assess and recondition grafts before transplant. During normothermic machine perfusion, metabolic activity is typically maintained using red blood cell (RBC)-based solutions. However, the utilization of RBCs creates important logistical constraints. This study explored the feasibility of human kidney normothermic perfusion using William's E-based perfusate with no additional oxygen carrier. Methods Sixteen human kidneys declined for transplant were perfused with a perfusion solution containing packed RBCs or William's E medium only for 6 h using a pressure-controlled system. The temperature was set at 37 °C. Renal artery resistance, oxygen extraction, metabolic activity, energy metabolism, and histological features were evaluated. Results Baseline donor demographics were similar in both groups. Throughout perfusion, kidneys perfused with William's E exhibited improved renal flow (P = 0.041) but similar arterial resistance. Lactic acid levels remained higher in kidneys perfused with RBCs during the first 3 h of perfusion but were similar thereafter (P = 0.95 at 6 h). Throughout perfusion, kidneys from both groups exhibited comparable behavior regarding oxygen consumption (P = 0.41) and reconstitution of ATP tissue concentration (P = 0.55). Similarly, nicotinamide adenine dinucleotide levels were preserved during perfusion. There was no evidence of histological damage caused by either perfusate. Conclusions In human kidneys, William's E medium provides a logistically convenient, off-the-shelf alternative to packed RBCs for up to 6 h of normothermic machine perfusion.
Collapse
Affiliation(s)
- Alban Longchamp
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Fermin M. Fontan
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Mohamed M. Aburawi
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Corey Eymard
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Negin Karimian
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Danielle Detelich
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Casie Pendexter
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Stephanie Cronin
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Thomas Agius
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Sonal Nagpal
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Peony Dutta Banik
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Shannon N. Tessier
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Sinan Ozer
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Francis L. Delmonico
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- New England Donor Services, Waltham, MA
| | - Korkut Uygun
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - Heidi Yeh
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| | - James F. Markmann
- Division of Transplantation, Department of Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
- Department of Surgery, Center for Engineering in Medicine and Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, MA
| |
Collapse
|
8
|
van Leeuwen LL, Ruigrok MJR, Kessler BM, Leuvenink HGD, Olinga P. Targeted delivery of galunisertib using machine perfusion reduces fibrogenesis in an integrated ex vivo renal transplant and fibrogenesis model. Br J Pharmacol 2024; 181:464-479. [PMID: 37596999 DOI: 10.1111/bph.16220] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 06/23/2023] [Accepted: 08/09/2023] [Indexed: 08/21/2023] Open
Abstract
BACKGROUND AND PURPOSE Fibrosis in kidney allografts is a major post-transplant complication that contributes to graft failure. Lately, multiple potent inhibitors of fibrosis-related pathways have been developed such as galunisertib, an inhibitor of the transforming growth factor-beta (TGF-β/TGFβ1) signalling pathway. This drug, however, poses risks for adverse effects when administered systemically. Therefore, we devised a new repurposing strategy in which galunisertib is administered ex vivo. We combined machine perfusion and tissue slices to explore the antifibrotic effects of galunisertib in renal grafts. EXPERIMENTAL APPROACH Porcine kidneys were subjected to 30 min of warm ischaemia, 24 h of oxygenated hypothermic machine perfusion and 6 h of normothermic machine perfusion with various treatments (i.e. untreated control, TGFβ1, galunisertib or TGFβ1 + galunisertib; n = 8 kidneys per group). To determine whether effects persisted upon ceasing treatment, kidney slices were prepared from respective kidneys and incubated for 48 h. KEY RESULTS Galunisertib treatment improved general viability without negatively affecting renal function or elevating levels of injury markers or by-products of oxidative stress during perfusion. Galunisertib also reduced inflammation and, more importantly, reduced the onset of fibrosis after 48 h of incubation. CONCLUSIONS AND IMPLICATIONS Our findings demonstrate the value of using machine perfusion for administering antifibrotic drugs such as galunisertib, proving it to be an effective example of repurposing.
Collapse
Affiliation(s)
- L Leonie van Leeuwen
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
- Nuffield Department of Medicine, Centre for Medicines Discovery, Target Discovery Institute, University of Oxford, Oxford, UK
- Recanati/Miller Transplantation Institute, Icahn School of Medicine at Mount Sinai, New York City, New York, USA
| | - Mitchel J R Ruigrok
- Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands
| | - Benedikt M Kessler
- Nuffield Department of Medicine, Centre for Medicines Discovery, Target Discovery Institute, University of Oxford, Oxford, UK
| | - Henri G D Leuvenink
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Peter Olinga
- Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, The Netherlands
| |
Collapse
|
9
|
Mazilescu LI, Goto T, John R, Rosales R, Ganesh S, Yu F, Noguchi Y, Kawamura M, Dezard V, Gao F, Urbanellis P, Parmentier C, Konvalinka A, Bagli DJ, Reichman TW, Robinson LA, Selzner M. Combining Oxygenated Cold Perfusion With Normothermic Ex Vivo Perfusion Improves the Outcome of Donation After Circulatory Death Porcine Kidney Transplantation. Transplantation 2024; 108:184-191. [PMID: 37505906 DOI: 10.1097/tp.0000000000004734] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/30/2023]
Abstract
BACKGROUND Ex vivo machine perfusion is a novel preservation technique for storing and assessing marginal kidney grafts. All ex vivo perfusion techniques have advantages and shortcomings. The current study analyzed whether a combination of oxygenated hypothermic machine perfusion (oxHMP) followed by a short period of normothermic ex vivo kidney perfusion (NEVKP) could combine the advantages of both techniques. METHODS Porcine kidneys were exposed to 30 min of warm ischemia followed by perfusion. Kidneys underwent either 16-h NEVKP or 16-h oxHMP. The third group was exposed to 16-h oxHMP followed by 3-h NEVKP (oxHMP + NEVKP group). After contralateral nephrectomy, grafts were autotransplanted and animals were followed up for 8 d. RESULTS All animals survived the follow-up period. Grafts preserved by continuous NEVKP showed improved function with lower peak serum creatinine and more rapid recovery compared with the other 2 groups. Urine neutrophil gelatinase-associated lipocalin, a marker of kidney injury, was found to be significantly lowered on postoperative day 3 in the oxHMP + NEVKP group compared with the other 2 groups. CONCLUSIONS A short period of NEVKP after oxHMP provides comparable short-term outcomes to prolonged NEVKP and is superior to oxHMP alone. A combination of oxHMP with end-ischemic NEVKP could be an attractive, practical strategy to combine the advantages of both preservation techniques.
Collapse
Affiliation(s)
- Laura Ioana Mazilescu
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of Nephrology, The Hospital for Sick Children, Toronto, ON, Canada
- Department of General, Visceral, and Transplantation Surgery, University Hospital Essen, Essen, Germany
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Toru Goto
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Rohan John
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
- Department of Pathology, University Health Network, Toronto, ON, Canada
| | - Roizar Rosales
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Sujani Ganesh
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
| | - Frank Yu
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
| | - Yuki Noguchi
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Masataka Kawamura
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of Nephrology, The Hospital for Sick Children, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Victoria Dezard
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
| | - Fei Gao
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
| | - Peter Urbanellis
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Catherine Parmentier
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Ana Konvalinka
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Department of Laboratory Medicine and Pathobiology, University of Toronto, Toronto, ON, Canada
- Division of Nephrology, Department of Medicine, University Health Network, University of Toronto, Toronto, ON, Canada
- Toronto General Hospital Research Institute, University Health Network, Toronto, ON, Canada
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada
| | - Darius J Bagli
- Department of Urology, The Hospital for Sick Children, University of Toronto, Toronto, ON, Canada
| | - Trevor W Reichman
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| | - Lisa A Robinson
- Division of Nephrology, The Hospital for Sick Children, Toronto, ON, Canada
- Institute of Medical Science, University of Toronto, Toronto, ON, Canada
- Program in Cell Biology, The Hospital for Sick Children Research Institute, Toronto, ON, Canada
| | - Markus Selzner
- Ajmera Transplant Centre, Toronto General Hospital, Toronto, ON, Canada
- Division of General Surgery, University Health Network, Toronto, ON, Canada
| |
Collapse
|
10
|
Fang Y, van Ooijen L, Ambagtsheer G, Nikolaev AV, Clahsen-van Groningen MC, Dankelman J, de Bruin RWF, Minnee RC. Real-time laser speckle contrast imaging measurement during normothermic machine perfusion in pretransplant kidney assessment. Lasers Surg Med 2023; 55:784-793. [PMID: 37555246 DOI: 10.1002/lsm.23715] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2023] [Revised: 07/31/2023] [Accepted: 07/31/2023] [Indexed: 08/10/2023]
Abstract
OBJECTIVES Normothermic machine perfusion (NMP) provides a platform for pre-transplant kidney quality assessment that is essential for the use of marginal donor kidneys. Laser speckle contrast imaging (LSCI) presents distinct advantages as a real-time and noncontact imaging technique for measuring microcirculation. In this study, we aimed to assess the value of LSCI in visualizing renal cortical perfusion and investigate the additional value of dual-side LSCI measurements compared to single aspect measurement during NMP. METHODS Porcine kidneys were obtained from a slaughterhouse and then underwent NMP. LSCI was used to measure one-sided cortical perfusion in the first 100 min of NMP. Thereafter, the inferior renal artery branch was occluded to induce partial ischemia and LSCI measurements on both ventral and dorsal sides were performed. RESULTS LSCI fluxes correlated linearly with the renal blood flow (R2 = 0.90, p < 0.001). After renal artery branch occlusion, absence of renal cortical perfusion could be visualized and semiquantified by LSCI. The overall ischemic area percentage of the ventral and dorsal sides was comparable (median interquartile range [IQR], 38 [24-43]% vs. 29 [17-46]%, p = 0.43), but heterogenous patterns between the two aspects were observed. There was a significant difference in oxygen consumption (mean ± standard deviation [SD], 2.57 ± 0.63 vs. 1.83 ± 0.49 mLO2 /min/100 g, p < 0.001), urine output (median [IQR], 1.3 [1.1-1.7] vs. 0.8 [0.6-1.3] mL/min, p < 0.05), lactate dehydrogenase (mean ± SD, 768 ± 370 vs. 905 ± 401 U/L, p < 0.05) and AST (mean ± SD, 352 ± 285 vs. 462 ± 383 U/L, p < 0.01) before and after renal artery occlusion, while no significant difference was found in creatinine clearance, fractional excretion of sodium, total sodium reabsorption and histological damage. CONCLUSIONS LSCI fluxes correlated linearly with renal blood flow during NMP. Renal cortical microcirculation and absent perfusion can be visualized and semiquantified by LSCI. It provides a relative understanding of perfusion levels, allowing for a qualitative comparison between regions in the kidney. Dual-side LSCI measurements are of added value compared to single aspect measurement and renal function markers.
Collapse
Affiliation(s)
- Yitian Fang
- Department of Surgery, Division of HPB and Transplant Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Lisanne van Ooijen
- Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
| | - Gisela Ambagtsheer
- Department of Surgery, Division of HPB and Transplant Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Anton V Nikolaev
- Department of Cardiology, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Marian C Clahsen-van Groningen
- Department of Pathology and Clinical Bioinformatics, Erasmus Medical Center, Rotterdam, the Netherlands
- Institute of Experimental and Systems Biology, RWTH Aachen University, Aachen, Germany
| | - Jenny Dankelman
- Department of Biomechanical Engineering, Delft University of Technology, Delft, the Netherlands
| | - Ron W F de Bruin
- Department of Surgery, Division of HPB and Transplant Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| | - Robert C Minnee
- Department of Surgery, Division of HPB and Transplant Surgery, Transplant Institute, Erasmus Medical Center, Rotterdam, the Netherlands
| |
Collapse
|
11
|
Huijink TM, van 't Hof CJ, van Furth LA, de Haan NA, Maassen H, Venema LH, Lammerts RGM, van den Heuvel MC, Hillebrands JL, van den Born J, Berger SP, Leuvenink HGD. Loss of Endothelial Glycocalyx During Normothermic Machine Perfusion of Porcine Kidneys Irrespective of Pressure and Hematocrit. Transplant Direct 2023; 9:e1507. [PMID: 37456589 PMCID: PMC10348736 DOI: 10.1097/txd.0000000000001507] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2023] [Accepted: 05/09/2023] [Indexed: 07/18/2023] Open
Abstract
Normothermic machine perfusion (NMP) is a promising modality for marginal donor kidneys. However, little is known about the effects of NMP on causing endothelial glycocalyx (eGC) injury. This study aims to evaluate the effects of NMP on eGC injury in marginal donor kidneys and whether this is affected by perfusion pressures and hematocrits. Methods Porcine slaughterhouse kidneys (n = 6/group) underwent 35 min of warm ischemia. Thereafter, the kidneys were preserved with oxygenated hypothermic machine perfusion for 3 h. Subsequently, 4 h of NMP was applied using pressure-controlled perfusion with an autologous blood-based solution containing either 12%, 24%, or 36% hematocrit. Pressures of 55, 75, and 95 mm Hg were applied in the 24% group. Perfusate, urine, and biopsy samples were collected to determine both injury and functional parameters. Results During NMP, hyaluronan levels in the perfusate increased significantly (P < 0.0001). In addition, the positivity of glyco-stained glycocalyx decreased significantly over time, both in the glomeruli (P = 0.024) and peritubular capillaries (P = 0.003). The number of endothelial cells did not change during NMP (P = 0.157), whereas glomerular endothelial expression of vascular endothelial growth factor receptor-2 decreased significantly (P < 0.001). Microthrombi formation was significantly increased after NMP. The use of different pressures and hematocrits did not affect functional parameters during perfusion. Conclusions NMP is accompanied with eGC and vascular endothelial growth factor receptor-2 loss, without significant loss of endothelial cells. eGC loss was not affected by the different pressures and hematocrits used. It remains unclear whether endothelial injury during NMP has harmful consequences for the transplanted kidney.
Collapse
Affiliation(s)
- Tobias M Huijink
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Cor J van 't Hof
- Department of Nephrology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - L Annick van Furth
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Nora A de Haan
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Hanno Maassen
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Leonie H Venema
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Rosa G M Lammerts
- Department of Transplantation Immunology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Marius C van den Heuvel
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Jan-Luuk Hillebrands
- Department of Pathology and Medical Biology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Jacob van den Born
- Department of Nephrology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Stefan P Berger
- Department of Nephrology, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| | - Henri G D Leuvenink
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, the Netherlands
| |
Collapse
|
12
|
Rother T, Horgby C, Schmalkuche K, Burgmann JM, Nocke F, Jägers J, Schmitz J, Bräsen JH, Cantore M, Zal F, Ferenz KB, Blasczyk R, Figueiredo C. Oxygen carriers affect kidney immunogenicity during ex-vivo machine perfusion. FRONTIERS IN TRANSPLANTATION 2023; 2:1183908. [PMID: 38993849 PMCID: PMC11235266 DOI: 10.3389/frtra.2023.1183908] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/10/2023] [Accepted: 05/29/2023] [Indexed: 07/13/2024]
Abstract
Normothermic ex-vivo machine perfusion provides a powerful tool to improve donor kidney preservation and a route for the delivery of pharmacological or gene therapeutic interventions prior to transplantation. However, perfusion at normothermic temperatures requires adequate tissue oxygenation to meet the physiological metabolic demand. For this purpose, the addition of appropriate oxygen carriers (OCs) to the perfusion solution is essential to ensure a sufficient oxygen supply and reduce the risk for tissue injury due to hypoxia. It is crucial that the selected OCs preserve the integrity and low immunogenicity of the graft. In this study, the effect of two OCs on the organ's integrity and immunogenicity was evaluated. Porcine kidneys were perfused ex-vivo for four hours using perfusion solutions supplemented with red blood cells (RBCs) as conventional OC, perfluorocarbon (PFC)-based OC, or Hemarina-M101 (M101), a lugworm hemoglobin-based OC named HEMO2life®, recently approved in Europe (i.e., CE obtained in October 2022). Perfusions with all OCs led to decreased lactate levels. Additionally, none of the OCs negatively affected renal morphology as determined by histological analyses. Remarkably, all OCs improved the perfusion solution by reducing the expression of pro-inflammatory mediators (IL-6, IL-8, TNFα) and adhesion molecules (ICAM-1) on both transcript and protein level, suggesting a beneficial effect of the OCs in maintaining the low immunogenicity of the graft. Thus, PFC-based OCs and M101 may constitute a promising alternative to RBCs during normothermic ex-vivo kidney perfusion.
Collapse
Affiliation(s)
- Tamina Rother
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| | - Carina Horgby
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| | - Katharina Schmalkuche
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| | - Jonathan M. Burgmann
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| | - Fabian Nocke
- Institute of Physiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Johannes Jägers
- Department of Biomedicine, Aarhus University, Aarhus, Denmark
| | - Jessica Schmitz
- Nephropathology Unit, Institute of Pathology, Hannover Medical School, Hannover, Germany
| | - Jan Hinrich Bräsen
- Nephropathology Unit, Institute of Pathology, Hannover Medical School, Hannover, Germany
| | - Miriam Cantore
- Institute of Physiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Franck Zal
- Hemarina SA, Aéropôle Centre, Morlaix, France
| | - Katja B. Ferenz
- Institute of Physiology, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
- CeNIDE (Center for Nanointegration Duisburg-Essen), University of Duisburg-Essen, Duisburg, Germany
| | - Rainer Blasczyk
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| | - Constanca Figueiredo
- Institute of Transfusion Medicine and Transplant Engineering, Hannover Medical School, Hannover, Germany
| |
Collapse
|
13
|
Foguenne M, MacMillan S, Kron P, Nath J, Devresse A, De Meyer M, Michel M, Hosgood S, Darius T. Current Evidence and Future Perspectives to Implement Continuous and End-Ischemic Use of Normothermic and Oxygenated Hypothermic Machine Perfusion in Clinical Practice. J Clin Med 2023; 12:3207. [PMID: 37176647 PMCID: PMC10178893 DOI: 10.3390/jcm12093207] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Revised: 04/26/2023] [Accepted: 04/27/2023] [Indexed: 05/15/2023] Open
Abstract
The use of high-risk renal grafts for transplantation requires the optimization of pretransplant assessment and preservation reconditioning strategies to decrease the organ discard rate and to improve short- and long-term clinical outcomes. Active oxygenation is increasingly recognized to play a central role in dynamic preservation strategies, independent of preservation temperature, to recondition mitochondria and to restore the cellular energy profile. The oxygen-related decrease in mitochondrial succinate accumulation ameliorates the harmful effects of ischemia-reperfusion injury. The differences between normothermic and hypothermic machine perfusion with regard to organ assessment, preservation, and reconditioning, as well as the logistic and economic implications, are factors to take into consideration for implementation at a local level. Therefore, these different techniques should be considered complementary to the perfusion strategy selected depending on functional intention and resource availability. This review provides an overview of the current clinical evidence of normothermic and oxygenated hypothermic machine perfusion, either as a continuous or end-ischemic preservation strategy, and future perspectives.
Collapse
Affiliation(s)
- Maxime Foguenne
- Surgery and Abdominal Transplant Unit, Department of Surgery, University Clinics Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - Serena MacMillan
- Department of Surgery, University of Cambridge, Addenbrooke’s Hospital, Cambridge CB2 0QQ, UK
| | - Philipp Kron
- Department of Surgery and Transplantation, Swiss HPB Center, University Hospital Zurich, 8091 Zurich, Switzerland
| | - Jay Nath
- Department of Renal Transplantation, Southmead Hospital Bristol, Bristol BS10 5NB, UK
| | - Arnaud Devresse
- Surgery and Abdominal Transplant Unit, Department of Surgery, University Clinics Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
- Department of Nephrology, University Clinics Saint-Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - Martine De Meyer
- Surgery and Abdominal Transplant Unit, Department of Surgery, University Clinics Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - Mourad Michel
- Surgery and Abdominal Transplant Unit, Department of Surgery, University Clinics Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
| | - Sarah Hosgood
- Department of Surgery, University of Cambridge, Addenbrooke’s Hospital, Cambridge CB2 0QQ, UK
| | - Tom Darius
- Surgery and Abdominal Transplant Unit, Department of Surgery, University Clinics Saint Luc, Université Catholique de Louvain, 1200 Brussels, Belgium
| |
Collapse
|
14
|
The impact of oxygen supply and erythrocytes during normothermic kidney perfusion. Sci Rep 2023; 13:2021. [PMID: 36737505 PMCID: PMC9898236 DOI: 10.1038/s41598-023-29031-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2022] [Accepted: 01/30/2023] [Indexed: 02/05/2023] Open
Abstract
The influence of erythrocytes and oxygen concentration on kidneys during long-term normothermic kidney perfusion is under debate. This study compares acellular and erythrocyte-based NMP with focus on oxygen delivery to the tissue as well as the effects of high oxygenation on tissue integrity. Pig kidneys were connected to NMP for six hours. The first group (n = 6; AC500) was perfused without addition of oxygen carriers, arterial perfusate pO2 was maintained at 500 mmHg. In the second group (n = 6; RBC500) washed erythrocytes were added to the perfusate at pO2 of 500 mmHg. Third group (n = 6; RBC200) was perfused with erythrocyte containing perfusate at more physiological pO2 of 200 mmHg. Addition of RBC did not relevantly increase oxygen consumption of the kidneys during perfusion. Likewise, there were no differences in kidney functional and injury parameters between AC500 and RBC500 group. Expression of erythropoietin as indicator of tissue hypoxia was comparable in all three groups. Cell free NMP at supraphysiological oxygen partial pressure seems to be a safe alternative to erythrocyte based perfusion without adverse effect on kidney integrity and provides a less cumbersome application of NMP in clinical practice.
Collapse
|
15
|
Messner F, Bogensperger C, Hunter JP, Kaths MJ, Moers C, Weissenbacher A. Normothermic machine perfusion of kidneys: current strategies and future perspectives. Curr Opin Organ Transplant 2022; 27:446-453. [PMID: 35857331 DOI: 10.1097/mot.0000000000001003] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
PURPOSE OF REVIEW This review aims to summarize the latest original preclinical and clinical articles in the setting of normothermic machine perfusion (NMP) of kidney grafts. RECENT FINDINGS Kidney NMP can be safely translated into the clinical routine and there is increasing evidence that NMP may be beneficial in graft preservation especially in marginal kidney grafts. Due to the near-physiological state during NMP, this technology may be used as an ex-vivo organ assessment and treatment platform. There are reports on the application of mesenchymal stromal/stem cells, multipotent adult progenitor cells and microRNA during kidney NMP, with first data indicating that these therapies indeed lead to a decrease in inflammatory response and kidney injury. Together with the demonstrated possibility of prolonged ex-vivo perfusion without significant graft damage, NMP could not only be used as a tool to perform preimplant graft assessment. Some evidence exists that it truly has the potential to be a platform to treat and repair injured kidney grafts, thereby significantly reducing the number of declined organs. SUMMARY Kidney NMP is feasible and can potentially increase the donor pool not only by preimplant graft assessment, but also by ex-vivo graft treatment.
Collapse
Affiliation(s)
- Franka Messner
- Department of Visceral, Transplant and Thoracic Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - Christina Bogensperger
- Department of Visceral, Transplant and Thoracic Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | - James P Hunter
- Oxford Transplant Centre, Nuffield Department of Surgical Sciences, University of Oxford, Oxford
- University Hospitals Coventry and Warwickshire NHS Trust, Coventry, UK
| | - Moritz J Kaths
- Department of General, Visceral and Transplantation Surgery, Faculty of Medicine, University Hospital Essen, University of Duisburg-Essen, Essen, Germany
| | - Cyril Moers
- Department of Surgery-Organ Donation and Transplantation, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands
| | - Annemarie Weissenbacher
- Department of Visceral, Transplant and Thoracic Surgery, Medical University of Innsbruck, Innsbruck, Austria
| |
Collapse
|
16
|
Normothermic Machine Perfusion in Renal Transplantation. CURRENT TRANSPLANTATION REPORTS 2022. [DOI: 10.1007/s40472-022-00378-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Abstract
Purpose of Review
Normothermic machine perfusion (NMP) is a promising new tool in kidney transplantation to improve the outcome of marginal donor kidney transplantation. This review examines the current evidence for NMP in clinical practice and considers how the technology may be used in the future.
Recent Findings and Summary
There is emerging evidence to suggest that NMP has the potential to expand the donor pool of transplantable organs. The safety and feasibility of NMP have been established in a number of clinical studies but more research is needed to optimise the perfusion conditions. NMP shows promise as a viability assessment tool with particular focus on biomarkers and imaging techniques which provide real-time information to facilitate transplantation decision-making. Moreover, the exciting development of new potential therapeutics such as cell and gene-based therapies which are deliverable during NMP may also improve and recondition grafts prior to implantation.
Collapse
|
17
|
Hosgood SA, Elliott TR, Jordan NP, Nicholson ML. The Effects of Free Heme on Functional and Molecular Changes During Ex Vivo Normothermic Machine Perfusion of Human Kidneys. Front Immunol 2022; 13:849742. [PMID: 35585981 PMCID: PMC9108696 DOI: 10.3389/fimmu.2022.849742] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2022] [Accepted: 04/04/2022] [Indexed: 11/16/2022] Open
Abstract
Normothermic machine perfusion (NMP) is a technique of kidney preservation designed to restore cellular metabolism after cold ischemia. Kidneys are perfused with an oxygenated banked red blood cell (RBC) based solution for 1h at 36°C. During NMP, RBCs can become damaged, releasing free heme into the perfusate. This can act as a damage-associated molecular pattern (DAMP) activating inflammatory signalling pathways. The aim of this study was to measure the levels of free heme during NMP, assess the effect on kidney function and determine any association with inflammatory and stress related gene expression. Levels of free heme were measured in perfusate samples from a series of donation after circulatory death (DCD) kidneys undergoing NMP as part of a randomised controlled trial (RCT). The age of RBCs and levels of free heme were correlated with perfusion parameters. Changes in gene expression were analysed in a series of kidneys declined for transplantation using the NanoString nCounter Organ Transplant Panel and qRT-PCR. Older units of RBCs were associated with higher levels of free heme and levels increased significantly during NMP (Pre 8.56 ± 7.19µM vs 26.29 ± 15.18µM, P<0.0001). There was no association with levels of free heme and perfusion parameters during NMP (P > 0.05). Transcriptional and qPCR analysis demonstrated the upregulation of differentially expressed genes associated with apoptosis (FOS and JUN), inflammatory cytokines (IL-6, SOCS3, ATF3), chemokines (CXCL8, CXCL2, CC3/L1) and oxidative stress (KLF4) after NMP. However, these did not correlate with levels of free heme (P >0.05). A significant amount of free heme can be detected in the perfusate before and after NMP particularly when older units of red cells are used. Although transcriptional analysis demonstrated significant upregulation of genes involved with apoptotic, inflammatory and oxidative pathways these were not associated with high levels of free heme.
Collapse
|
18
|
Exploring Porcine Precision-Cut Kidney Slices as a Model for Transplant-Related Ischemia-Reperfusion Injury. TRANSPLANTOLOGY 2022. [DOI: 10.3390/transplantology3020015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
Marginal donor kidneys are more likely to develop ischemia-reperfusion injury (IRI), resulting in inferior long-term outcomes. Perfusion techniques are used to attenuate IRI and improve graft quality. However, machine perfusion is still in its infancy, and more research is required for optimal conditions and potential repairing therapies. Experimental machine perfusion using porcine kidneys is a great way to investigate transplant-related IRI, but these experiments are costly and time-consuming. Therefore, an intermediate model to study IRI would be of great value. We developed a precision-cut kidney slice (PCKS) model that resembles ischemia-reperfusion and provides opportunities for studying multiple interventions simultaneously. Porcine kidneys were procured from a local slaughterhouse, exposed to 30 min of warm ischemia, and cold preserved. Subsequently, PCKS were prepared and incubated under various conditions. Adenosine triphosphate (ATP) levels and histological tissue integrity were assessed for renal viability and injury. Slicing did not influence tissue viability, and PCKS remained viable up to 72 h incubation with significantly increased ATP levels. Hypothermic and normothermic incubation led to significantly higher ATP levels than baseline. William’s medium E supplemented with Ciprofloxacin (and Amphotericin-B) provided the most beneficial condition for incubation of porcine PCKS. The porcine PCKS model can be used for studying transplant IRI.
Collapse
|
19
|
van Leeuwen L, Venema LH, Heilig R, Leuvenink HGD, Kessler BM. Doxycycline Alters the Porcine Renal Proteome and Degradome during Hypothermic Machine Perfusion. Curr Issues Mol Biol 2022; 44:559-577. [PMID: 35723325 PMCID: PMC8928973 DOI: 10.3390/cimb44020039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/17/2022] [Accepted: 01/19/2022] [Indexed: 11/16/2022] Open
Abstract
Ischemia-reperfusion injury (IRI) is a hallmark for tissue injury in donation after circulatory death (DCD) kidneys. The implementation of hypothermic machine perfusion (HMP) provides a platform for improved preservation of DCD kidneys. Doxycycline administration has shown protective effects during IRI. Therefore, we explored the impact of doxycycline on proteolytic degradation mechanisms and the urinary proteome of perfused kidney grafts. Porcine kidneys underwent 30 min of warm ischemia, 24 h of oxygenated HMP (control/doxycycline) and 240 min of ex vivo reperfusion. A proteomic analysis revealed distinctive clustering profiles between urine samples collected at T15 min and T240 min. High-efficiency undecanal-based N-termini (HUNTER) kidney tissue degradomics revealed significantly more proteolytic activity in the control group at T-10. At T240, significantly more proteolytic activity was observed in the doxycycline group, indicating that doxycycline alters protein degradation during HMP. In conclusion, doxycycline administration during HMP led to significant proteomic and proteolytic differences and protective effects by attenuating urinary NGAL levels. Ultimately, we unraveled metabolic, and complement and coagulation pathways that undergo alterations during machine perfusion and that could be targeted to attenuate IRI induced injury.
Collapse
Affiliation(s)
- Leonie van Leeuwen
- Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.H.V.); (H.G.D.L.)
- Centre for Medicines Discovery, Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford OX3 7FZ, UK; (R.H.); (B.M.K.)
- Correspondence:
| | - Leonie H. Venema
- Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.H.V.); (H.G.D.L.)
| | - Raphael Heilig
- Centre for Medicines Discovery, Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford OX3 7FZ, UK; (R.H.); (B.M.K.)
| | - Henri G. D. Leuvenink
- Department of Surgery, University Medical Center Groningen, University of Groningen, 9713 GZ Groningen, The Netherlands; (L.H.V.); (H.G.D.L.)
| | - Benedikt M. Kessler
- Centre for Medicines Discovery, Nuffield Department of Medicine, Target Discovery Institute, University of Oxford, Oxford OX3 7FZ, UK; (R.H.); (B.M.K.)
- Nuffield Department of Medicine, Chinese Academy of Medical Sciences Oxford Institute, University of Oxford, Oxford OX3 7FZ, UK
| |
Collapse
|
20
|
van Leeuwen LL, Leuvenink HGD, Olinga P, Ruigrok MJR. Shifting Paradigms for Suppressing Fibrosis in Kidney Transplants: Supplementing Perfusion Solutions With Anti-fibrotic Drugs. Front Med (Lausanne) 2022; 8:806774. [PMID: 35083254 PMCID: PMC8784659 DOI: 10.3389/fmed.2021.806774] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Accepted: 12/16/2021] [Indexed: 12/16/2022] Open
Abstract
Great efforts have been made toward addressing the demand for donor kidneys. One of the most promising approaches is to use kidneys from donation after circulatory death donors. These kidneys, however, suffer from more severe ischemia and reperfusion injury than those obtained via donation after brain death and are thus more prone to develop interstitial fibrosis and tubular atrophy. Even though machine perfusion is increasingly used to reduce ischemia and reperfusion injury, there are no effective treatments available to ameliorate interstitial fibrosis and tubular atrophy, forcing patients to resume dialysis, undergo re-transplantation, or suffer from premature death. Safe and effective anti-fibrotic therapies are therefore greatly desired. We propose a new therapeutic approach in which machine perfusion solutions are supplemented with anti-fibrotic compounds. This allows the use of higher concentrations than those used in humans whilst eliminating side effects in other organs. To the authors' knowledge, no one has reviewed whether such an approach could reduce interstitial fibrosis and tubular atrophy; we therefore set out to explore its merit. In this review, we first provide background information on ischemia and reperfusion injury as well as interstitial fibrosis and tubular atrophy, after which we describe currently available approaches for preserving donor kidneys. We then present an evaluation of selected compounds. To identify promising compounds, we analyzed publications describing the effects of anti-fibrotic molecules in precision-cut kidneys slices, which are viable explants that can be cultured ex vivo for up to a few days whilst retaining functional and structural features. LY2109761, galunisertib, imatinib, nintedanib, and butaprost were shown to exert anti-fibrotic effects in slices within a relatively short timeframe (<48 h) and are therefore considered to be excellent candidates for follow-up ex vivo machine perfusion studies.
Collapse
Affiliation(s)
- L. Leonie van Leeuwen
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Henri G. D. Leuvenink
- Department of Surgery, University Medical Center Groningen, University of Groningen, Groningen, Netherlands
| | - Peter Olinga
- Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, Netherlands
| | - Mitchel J. R. Ruigrok
- Department of Pharmaceutical Technology and Biopharmacy, Groningen Research Institute of Pharmacy, University of Groningen, Groningen, Netherlands
| |
Collapse
|
21
|
Abstract
Machine perfusion techniques are becoming standard care in the clinical donation and transplantation setting. However, more research is needed to understand the mechanisms of the protective effects of machine perfusion. For preservation related experiments, porcine kidneys are acceptable alternatives to human kidneys, because of their size and similar physiology. In this experiment, the use of slaughterhouse kidneys was evaluated with normothermic kidney perfusion (NKP), thereby avoiding the use of laboratory animals. Porcine kidneys were derived from two local abattoirs. To induce different degrees of injury, different warm ischemic times and preservation techniques were used. After preservation, kidneys were reperfused for 4 h with two different NKP solutions to test renal function and damage. The effect of the preservation technique or a short warm ischemic time was clearly seen in functional markers, such as creatinine clearance and fractional sodium excretion levels, as well as in the generic damage marker lactate dehydrogenase (LDH). Porcine slaughterhouse kidneys are a useful alternative to laboratory animals for transplantation- and preservation-related research questions. To maintain kidney function during NKP, a short warm ischemic time or hypothermic machine perfusion during the preservation phase are mandatory.
Collapse
|