1
|
Cui K, Valencia J, Boyce KT, Clements ER, Leibrandt DR, Hume DB. Scalable Quantum Logic Spectroscopy. PHYSICAL REVIEW LETTERS 2022; 129:193603. [PMID: 36399738 DOI: 10.1103/physrevlett.129.193603] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2022] [Revised: 07/24/2022] [Accepted: 09/30/2022] [Indexed: 06/16/2023]
Abstract
In quantum logic spectroscopy (QLS), one species of trapped ion is used as a sensor to detect the state of an otherwise inaccessible ion species. This extends precision measurements to a broader class of atomic and molecular systems for applications like atomic clocks and tests of fundamental physics. Here, we develop a new technique based on a Schrödinger cat interferometer to address the problem of scaling QLS to larger ion numbers. We demonstrate the basic features of this method using various combinations of ^{25}Mg^{+} logic ions and ^{27}Al^{+} spectroscopy ions. We observe higher detection efficiency by increasing the number of ^{25}Mg^{+} ions. Applied to multiple ^{27}Al^{+}, this method will improve the stability of high-accuracy optical clocks and could enable Heisenberg-limited QLS.
Collapse
Affiliation(s)
- Kaifeng Cui
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
- HEP Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
- Key Laboratory of Atomic Frequency Standards, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences, Wuhan 430071, China
| | - Jose Valencia
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - Kevin T Boyce
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - Ethan R Clements
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - David R Leibrandt
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - David B Hume
- National Institute of Standards and Technology, Boulder, Colorado 80305, USA
| |
Collapse
|
2
|
Nordmann T, Didier A, Doležal M, Balling P, Burgermeister T, Mehlstäubler TE. Sub-kelvin temperature management in ion traps for optical clocks. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2020; 91:111301. [PMID: 33261420 DOI: 10.1063/5.0024693] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2020] [Accepted: 10/22/2020] [Indexed: 06/12/2023]
Abstract
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10-19 and even 10-20 regime for 171Yb+(E3) and 115In+, respectively.
Collapse
Affiliation(s)
- T Nordmann
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - A Didier
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - M Doležal
- Czech Metrology Institute (CMI), Okružní 31, 638 00 Brno, Czech Republic
| | - P Balling
- Czech Metrology Institute (CMI), Okružní 31, 638 00 Brno, Czech Republic
| | - T Burgermeister
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| | - T E Mehlstäubler
- Physikalisch-Technische Bundesanstalt (PTB), Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|
3
|
Kienzler D, Wan Y, Erickson SD, Wu JJ, Wilson AC, Wineland DJ, Leibfried D. Quantum Logic Spectroscopy with Ions in Thermal Motion. PHYSICAL REVIEW. X 2020; 10:10.1103/PhysRevX.10.021012. [PMID: 34136310 PMCID: PMC8204399 DOI: 10.1103/physrevx.10.021012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
A mixed-species geometric phase gate has been proposed for implementing quantum logic spectroscopy on trapped ions, which combines probe and information transfer from the spectroscopy to the logic ion in a single pulse. We experimentally realize this method, show how it can be applied as a technique for identifying transitions in currently intractable atoms or molecules, demonstrate its reduced temperature sensitivity, and observe quantum-enhanced frequency sensitivity when it is applied to multi-ion chains. Potential applications include improved readout of trapped-ion clocks and simplified error syndrome measurements for quantum error correction.
Collapse
Affiliation(s)
- D. Kienzler
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - Y. Wan
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - S. D. Erickson
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - J. J. Wu
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - A. C. Wilson
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| | - D. J. Wineland
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
- Department of Physics, University of Oregon, Eugene, Oregon 97403, USA
| | - D. Leibfried
- National Institute of Standards and Technology, Time and Frequency Division 688, 325 Broadway, Boulder, Colorado 80305, USA
- Department of Physics, University of Colorado, Boulder, Colorado 80305, USA
| |
Collapse
|
4
|
Hannig S, Pelzer L, Scharnhorst N, Kramer J, Stepanova M, Xu ZT, Spethmann N, Leroux ID, Mehlstäubler TE, Schmidt PO. Towards a transportable aluminium ion quantum logic optical clock. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:053204. [PMID: 31153262 DOI: 10.1063/1.5090583] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Accepted: 05/07/2019] [Indexed: 06/09/2023]
Abstract
With the advent of optical clocks featuring fractional frequency uncertainties on the order of 10-17 and below, new applications such as chronometric leveling with few-centimeter height resolution emerge. We are developing a transportable optical clock based on a single trapped aluminum ion, which is interrogated via quantum logic spectroscopy. We employ singly charged calcium as the logic ion for sympathetic cooling, state preparation, and readout. Here, we present a simple and compact physics and laser package for manipulation of 40Ca+. Important features are a segmented multilayer trap with separate loading and probing zones, a compact titanium vacuum chamber, a near-diffraction-limited imaging system with high numerical aperture based on a single biaspheric lens, and an all-in-fiber 40Ca+ repump laser system. We present preliminary estimates of the trap-induced frequency shifts on 27Al+, derived from measurements with a single calcium ion. The micromotion-induced second-order Doppler shift for 27Al+ has been determined to be δνEMMν=-0.4-0.3 +0.4×10-18 and the black-body radiation shift is δνBBR/ν = (-4.0 ± 0.4) × 10-18. Moreover, heating rates of 30 (7) quanta per second at trap frequencies of ωrad,Ca+ ≈ 2π × 2.5 MHz (ωax,Ca+ ≈ 2π × 1.5 MHz) in radial (axial) direction have been measured, enabling interrogation times of a few hundreds of milliseconds.
Collapse
Affiliation(s)
- S Hannig
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - L Pelzer
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - N Scharnhorst
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - J Kramer
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - M Stepanova
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - Z T Xu
- MOE Key Laboratory of Fundamental Physical Quantities Measurement, School of Physics, Huazhong University of Science and Technology, 430074 Wuhan, People's Republic of China
| | - N Spethmann
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - I D Leroux
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - T E Mehlstäubler
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | - P O Schmidt
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| |
Collapse
|
5
|
Abstract
Molecular overtone transitions provide optical frequency transitions sensitive to variation in the proton-to-electron mass ratio ( μ ≡ m p / m e ). However, robust molecular state preparation presents a challenge critical for achieving high precision. Here, we characterize infrared and optical-frequency broadband laser cooling schemes for TeH + , a species with multiple electronic transitions amenable to sustained laser control. Using rate equations to simulate laser cooling population dynamics, we estimate the fractional sensitivity to μ attainable using TeH + . We find that laser cooling of TeH + can lead to significant improvements on current μ variation limits.
Collapse
|
6
|
Mehlstäubler TE, Grosche G, Lisdat C, Schmidt PO, Denker H. Atomic clocks for geodesy. REPORTS ON PROGRESS IN PHYSICS. PHYSICAL SOCIETY (GREAT BRITAIN) 2018; 81:064401. [PMID: 29667603 DOI: 10.1088/1361-6633/aab409] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
We review experimental progress on optical atomic clocks and frequency transfer, and consider the prospects of using these technologies for geodetic measurements. Today, optical atomic frequency standards have reached relative frequency inaccuracies below 10-17, opening new fields of fundamental and applied research. The dependence of atomic frequencies on the gravitational potential makes atomic clocks ideal candidates for the search for deviations in the predictions of Einstein's general relativity, tests of modern unifying theories and the development of new gravity field sensors. In this review, we introduce the concepts of optical atomic clocks and present the status of international clock development and comparison. Besides further improvement in stability and accuracy of today's best clocks, a large effort is put into increasing the reliability and technological readiness for applications outside of specialized laboratories with compact, portable devices. With relative frequency uncertainties of 10-18, comparisons of optical frequency standards are foreseen to contribute together with satellite and terrestrial data to the precise determination of fundamental height reference systems in geodesy with a resolution at the cm-level. The long-term stability of atomic standards will deliver excellent long-term height references for geodetic measurements and for the modelling and understanding of our Earth.
Collapse
Affiliation(s)
- Tanja E Mehlstäubler
- Physikalisch-Technische Bundesanstalt, Bundesallee 100, 38116 Braunschweig, Germany
| | | | | | | | | |
Collapse
|
7
|
Zeng Y, Xu P, He X, Liu Y, Liu M, Wang J, Papoular DJ, Shlyapnikov GV, Zhan M. Entangling Two Individual Atoms of Different Isotopes via Rydberg Blockade. PHYSICAL REVIEW LETTERS 2017; 119:160502. [PMID: 29099205 DOI: 10.1103/physrevlett.119.160502] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/12/2017] [Indexed: 06/07/2023]
Abstract
We report on the first experimental realization of the controlled-not (cnot) quantum gate and entanglement for two individual atoms of different isotopes and demonstrate a negligible cross talk between two atom qubits. The experiment is based on a strong Rydberg blockade for ^{87}Rb and ^{85}Rb atoms confined in two single-atom optical traps separated by 3.8 μm. The raw fidelities of the cnot gate and entanglement are 0.73±0.01 and 0.59±0.03, respectively, without any corrections for atom loss or trace loss. Our work has applications for simulations of many-body systems with multispecies interactions, for quantum computing, and for quantum metrology.
Collapse
Affiliation(s)
- Yong Zeng
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
- School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Peng Xu
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Xiaodong He
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Yangyang Liu
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
- School of Physical Sciences, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Min Liu
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
| | - Jin Wang
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
| | - D J Papoular
- LPTM, UMR8089 of CNRS and Université de Cergy-Pontoise, F-95302 Cergy-Pontoise, France
| | - G V Shlyapnikov
- LPTMS, UMR8626 of CNRS and Université Paris-Sud, F-91405 Orsay, France
- SPEC, CEA & CNRS, Université Paris-Saclay, CEA Saclay, F-91191 Gif-sur-Yvette, France
- Russian Quantum Center, Novaya Street, Skolkovo, Moscow Region R-143025, Russia
- Van der Waals-Zeeman Institute, Institute of Physics, University of Amsterdam, The Netherlands
| | - Mingsheng Zhan
- State Key Laboratory of Magnetic Resonance and Atomic and Molecular Physics, Wuhan Institute of Physics and Mathematics, Chinese Academy of Sciences-Wuhan National Laboratory for Optoelectronics, Wuhan 430071, China
- Center for Cold Atom Physics, Chinese Academy of Sciences, Wuhan 430071, China
| |
Collapse
|
8
|
Tan TR, Gaebler JP, Lin Y, Wan Y, Bowler R, Leibfried D, Wineland DJ. Multi-element logic gates for trapped-ion qubits. Nature 2015; 528:380-3. [DOI: 10.1038/nature16186] [Citation(s) in RCA: 113] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2015] [Accepted: 10/26/2015] [Indexed: 11/09/2022]
|