1
|
Jahrman EP, Holden WM, Ditter AS, Mortensen DR, Seidler GT, Fister TT, Kozimor SA, Piper LFJ, Rana J, Hyatt NC, Stennett MC. An improved laboratory-based x-ray absorption fine structure and x-ray emission spectrometer for analytical applications in materials chemistry research. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2019; 90:024106. [PMID: 30831699 DOI: 10.1063/1.5049383] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2018] [Accepted: 02/01/2019] [Indexed: 06/09/2023]
Abstract
X-ray absorption fine structure (XAFS) and x-ray emission spectroscopy (XES) are advanced x-ray spectroscopies that impact a wide range of disciplines. However, unlike the majority of other spectroscopic methods, XAFS and XES are accompanied by an unusual access model, wherein the dominant use of the technique is for premier research studies at world-class facilities, i.e., synchrotron x-ray light sources. In this paper, we report the design and performance of an improved XAFS and XES spectrometer based on the general conceptual design of Seidler et al. [Rev. Sci. Instrum. 85, 113906 (2014)]. New developments include reduced mechanical degrees of freedom, much-increased flux, and a wider Bragg angle range to enable extended x-ray absorption fine structure (EXAFS) measurement and analysis for the first time with this type of modern laboratory XAFS configuration. This instrument enables a new class of routine applications that are incompatible with the mission and access model of the synchrotron light sources. To illustrate this, we provide numerous examples of x-ray absorption near edge structure (XANES), EXAFS, and XES results for a variety of problems and energy ranges. Highlights include XAFS and XES measurements of battery electrode materials, EXAFS of Ni with full modeling of results to validate monochromator performance, valence-to-core XES for 3d transition metal compounds, and uranium XANES and XES for different oxidation states. Taken en masse, these results further support the growing perspective that modern laboratory-based XAFS and XES have the potential to develop a new branch of analytical chemistry.
Collapse
Affiliation(s)
- Evan P Jahrman
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - William M Holden
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - Alexander S Ditter
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - Devon R Mortensen
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - Gerald T Seidler
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - Timothy T Fister
- Chemical Sciences and Engineering Division, Argonne National Laboratory, Lemont, Illinois 60439, USA
| | - Stosh A Kozimor
- Chemistry Division, Los Alamos National Laboratory, Los Alamos, New Mexico 87545, USA
| | - Louis F J Piper
- Department of Physics, Binghamton University, Binghamton, New York 13902, USA
| | - Jatinkumar Rana
- Department of Physics, Binghamton University, Binghamton, New York 13902, USA
| | - Neil C Hyatt
- Materials Science and Engineering Department, The University of Sheffield, Mapping Street, Sheffield S1 3JD, United Kingdom
| | - Martin C Stennett
- Materials Science and Engineering Department, The University of Sheffield, Mapping Street, Sheffield S1 3JD, United Kingdom
| |
Collapse
|
2
|
Seidler GT, Mortensen DR, Remesnik AJ, Pacold JI, Ball NA, Barry N, Styczinski M, Hoidn OR. A laboratory-based hard x-ray monochromator for high-resolution x-ray emission spectroscopy and x-ray absorption near edge structure measurements. THE REVIEW OF SCIENTIFIC INSTRUMENTS 2014; 85:113906. [PMID: 25430123 DOI: 10.1063/1.4901599] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Accepted: 11/03/2014] [Indexed: 05/22/2023]
Abstract
We report the development of a laboratory-based Rowland-circle monochromator that incorporates a low power x-ray (bremsstrahlung) tube source, a spherically bent crystal analyzer, and an energy-resolving solid-state detector. This relatively inexpensive, introductory level instrument achieves 1-eV energy resolution for photon energies of ∼5 keV to ∼10 keV while also demonstrating a net efficiency previously seen only in laboratory monochromators having much coarser energy resolution. Despite the use of only a compact, air-cooled 10 W x-ray tube, we find count rates for nonresonant x-ray emission spectroscopy comparable to those achieved at monochromatized spectroscopy beamlines at synchrotron light sources. For x-ray absorption near edge structure, the monochromatized flux is small (due to the use of a low-powered x-ray generator) but still useful for routine transmission-mode studies of concentrated samples. These results indicate that upgrading to a standard commercial high-power line-focused x-ray tube or rotating anode x-ray generator would result in monochromatized fluxes of order 10(6)-10(7) photons/s with no loss in energy resolution. This work establishes core technical capabilities for a rejuvenation of laboratory-based hard x-ray spectroscopies that could have special relevance for contemporary research on catalytic or electrical energy storage systems using transition-metal, lanthanide, or noble-metal active species.
Collapse
Affiliation(s)
- G T Seidler
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - D R Mortensen
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - A J Remesnik
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - J I Pacold
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - N A Ball
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - N Barry
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - M Styczinski
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| | - O R Hoidn
- Physics Department, University of Washington, Seattle, Washington 98195-1560, USA
| |
Collapse
|
4
|
Jakes P, Erdem E, Ozarowski A, Tol JV, Buckan R, Mikhailova D, Ehrenberg H, Eichel RA. Local coordination of Fe3+ in Li[Co0.98Fe0.02]O2 as cathode material for lithium ion batteries—multi-frequency EPR and Monte-Carlo Newman-superposition model analysis. Phys Chem Chem Phys 2011; 13:9344-52. [DOI: 10.1039/c0cp02048f] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|