Ismail TF, Strugnell W, Coletti C, Božić-Iven M, Weingärtner S, Hammernik K, Correia T, Küstner T. Cardiac MR: From Theory to Practice. Front Cardiovasc Med 2022; 9:826283. [PMID: 35310962 PMCID: PMC8927633 DOI: 10.3389/fcvm.2022.826283] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Accepted: 01/17/2022] [Indexed: 01/10/2023] Open
Abstract
Cardiovascular disease (CVD) is the leading single cause of morbidity and mortality, causing over 17. 9 million deaths worldwide per year with associated costs of over $800 billion. Improving prevention, diagnosis, and treatment of CVD is therefore a global priority. Cardiovascular magnetic resonance (CMR) has emerged as a clinically important technique for the assessment of cardiovascular anatomy, function, perfusion, and viability. However, diversity and complexity of imaging, reconstruction and analysis methods pose some limitations to the widespread use of CMR. Especially in view of recent developments in the field of machine learning that provide novel solutions to address existing problems, it is necessary to bridge the gap between the clinical and scientific communities. This review covers five essential aspects of CMR to provide a comprehensive overview ranging from CVDs to CMR pulse sequence design, acquisition protocols, motion handling, image reconstruction and quantitative analysis of the obtained data. (1) The basic MR physics of CMR is introduced. Basic pulse sequence building blocks that are commonly used in CMR imaging are presented. Sequences containing these building blocks are formed for parametric mapping and functional imaging techniques. Commonly perceived artifacts and potential countermeasures are discussed for these methods. (2) CMR methods for identifying CVDs are illustrated. Basic anatomy and functional processes are described to understand the cardiac pathologies and how they can be captured by CMR imaging. (3) The planning and conduct of a complete CMR exam which is targeted for the respective pathology is shown. Building blocks are illustrated to create an efficient and patient-centered workflow. Further strategies to cope with challenging patients are discussed. (4) Imaging acceleration and reconstruction techniques are presented that enable acquisition of spatial, temporal, and parametric dynamics of the cardiac cycle. The handling of respiratory and cardiac motion strategies as well as their integration into the reconstruction processes is showcased. (5) Recent advances on deep learning-based reconstructions for this purpose are summarized. Furthermore, an overview of novel deep learning image segmentation and analysis methods is provided with a focus on automatic, fast and reliable extraction of biomarkers and parameters of clinical relevance.
Collapse
Affiliation(s)
- Tevfik F. Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Cardiology Department, Guy's and St Thomas' Hospital, London, United Kingdom
| | - Wendy Strugnell
- Queensland X-Ray, Mater Hospital Brisbane, Brisbane, QLD, Australia
| | - Chiara Coletti
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
| | - Maša Božić-Iven
- Magnetic Resonance Systems Lab, Delft University of Technology, Delft, Netherlands
- Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Germany
| | | | - Kerstin Hammernik
- Lab for AI in Medicine, Technical University of Munich, Munich, Germany
- Department of Computing, Imperial College London, London, United Kingdom
| | - Teresa Correia
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Centre of Marine Sciences, Faro, Portugal
| | - Thomas Küstner
- Medical Image and Data Analysis (MIDAS.lab), Department of Diagnostic and Interventional Radiology, University Hospital of Tübingen, Tübingen, Germany
| |
Collapse
|
2
|
Moghari MH, Roujol S, Henningsson M, Kissinger KV, Annese D, Nezafat R, Manning WJ, Geva T, Powell AJ. Three-dimensional heart locator for whole-heart coronary magnetic resonance angiography. Magn Reson Med 2013; 71:2118-26. [PMID: 23878103 DOI: 10.1002/mrm.24881] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2013] [Revised: 06/19/2013] [Accepted: 06/20/2013] [Indexed: 01/08/2023]
Abstract
PURPOSE Coronary magnetic resonance angiography (MRA) is commonly performed with diaphragmatic navigator (NAV) gating to compensate for respiratory motion, but this approach is inefficient as data must be reacquired when it is outside the acceptance window. We therefore developed and validated a motion compensation technique based on three-dimensional (3D) spatial registration in which data are accepted throughout the respiratory cycle. METHODS A novel respiratory motion compensation method was implemented that acquires a low-resolution 3D-image of the heart (3D-LOC) just prior to coronary MRA data acquisition. 3D-LOC volumes were registered to the first 3D-LOC to estimate the respiratory-induced heart motion and to modify the coronary MRA data and reconstruct motion-corrected images. Whole-heart coronary MRA datasets were acquired from nine healthy subjects using a diaphragmatic NAV and using 3D-LOC. RESULTS There was no significant difference between the subjective image score of NAV and 3D-LOC in three main coronary branches. The vessel sharpness of 3D-LOC was higher than NAV in the right (0.44 ± 0.08 vs. 0.49 ± 0.08; P = 0.055) and left circumflex arteries (0.49 ± 0.05 vs. 0.52 ± 0.04; P = 0.039). Scan time for 3D-LOC was significantly shorter than NAV (4.3 ± 0.6 vs. 8.3 ± 2.3 min; P = 0.004). CONCLUSION Compared to NAV gating, 3D-LOC for coronary MRA reduces scan time by nearly 50% without compromising image quality.
Collapse
Affiliation(s)
- Mehdi H Moghari
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA; Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA; Department of Medicine, Harvard Medical School, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | |
Collapse
|
3
|
Moghari MH, Roujol S, Chan RH, Hong SN, Bello N, Henningsson M, Ngo LH, Goddu B, Goepfert L, Kissinger KV, Manning WJ, Nezafat R. Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction. Magn Reson Med 2012; 70:1005-15. [PMID: 23132549 DOI: 10.1002/mrm.24538] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2012] [Revised: 09/06/2012] [Accepted: 10/01/2012] [Indexed: 11/07/2022]
Abstract
Respiratory motion compensation using diaphragmatic navigator gating with a 5 mm gating window is conventionally used for free-breathing cardiac MRI. Because of the narrow gating window, scan efficiency is low resulting in long scan times, especially for patients with irregular breathing patterns. In this work, a new retrospective motion compensation algorithm is presented to reduce the scan time for free-breathing cardiac MRI that increasing the gating window to 15 mm without compromising image quality. The proposed algorithm iteratively corrects for respiratory-induced cardiac motion by optimizing the sharpness of the heart. To evaluate this technique, two coronary MRI datasets with 1.3 mm(3) resolution were acquired from 11 healthy subjects (seven females, 25 ± 9 years); one using a navigator with a 5 mm gating window acquired in 12.0 ± 2.0 min and one with a 15 mm gating window acquired in 7.1 ± 1.0 min. The images acquired with a 15 mm gating window were corrected using the proposed algorithm and compared to the uncorrected images acquired with the 5 and 15 mm gating windows. The image quality score, sharpness, and length of the three major coronary arteries were equivalent between the corrected images and the images acquired with a 5 mm gating window (P-value > 0.05), while the scan time was reduced by a factor of 1.7.
Collapse
Affiliation(s)
- Mehdi H Moghari
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
4
|
Wu HH, Gurney PT, Hu BS, Nishimura DG, McConnell MV. Free-breathing multiphase whole-heart coronary MR angiography using image-based navigators and three-dimensional cones imaging. Magn Reson Med 2012; 69:1083-93. [PMID: 22648856 DOI: 10.1002/mrm.24346] [Citation(s) in RCA: 63] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 04/30/2012] [Accepted: 05/01/2012] [Indexed: 11/10/2022]
Abstract
Noninvasive visualization of the coronary arteries in vivo is one of the most important goals in cardiovascular imaging. Compared to other paradigms for coronary MR angiography, a free-breathing three-dimensional whole-heart iso-resolution approach simplifies prescription effort, requires less patient cooperation, reduces overall exam time, and supports retrospective reformats at arbitrary planes. However, this approach requires a long continuous acquisition and must account for respiratory and cardiac motion throughout the scan. In this work, a new free-breathing coronary MR angiography technique that reduces scan time and improves robustness to motion is developed. Data acquisition is accomplished using a three-dimensional cones non-Cartesian trajectory, which can reduce the number of readouts 3-fold or more compared to conventional three-dimensional Cartesian encoding and provides greater robustness to motion/flow effects. To further enhance robustness to motion, two-dimensional navigator images are acquired to directly track respiration-induced displacement of the heart and enable retrospective compensation of all acquired data (none discarded) for image reconstruction. In addition, multiple cardiac phases are imaged to support retrospective selection of the best phase(s) for visualizing each coronary segment. Experimental results demonstrate that whole-heart coronary angiograms can be obtained rapidly and robustly with this proposed technique.
Collapse
Affiliation(s)
- Holden H Wu
- Division of Cardiovascular Medicine, Stanford University, Stanford, CA 94305-5233, USA.
| | | | | | | | | |
Collapse
|
5
|
Henningsson M, Smink J, Razavi R, Botnar RM. Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator. Magn Reson Med 2012; 69:486-94. [PMID: 22529009 DOI: 10.1002/mrm.24280] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2011] [Revised: 02/13/2012] [Accepted: 03/12/2012] [Indexed: 11/10/2022]
Affiliation(s)
- Markus Henningsson
- Division of Imaging Sciences and Biomedical Engineering, King's College London, London, United Kingdom.
| | | | | | | |
Collapse
|
6
|
Moghari MH, Akçakaya M, O'Connor A, Basha TA, Casanova M, Stanton D, Goepfert L, Kissinger KV, Goddu B, Chuang ML, Tarokh V, Manning WJ, Nezafat R. Compressed-sensing motion compensation (CosMo): a joint prospective-retrospective respiratory navigator for coronary MRI. Magn Reson Med 2011; 66:1674-81. [PMID: 21671266 PMCID: PMC3175251 DOI: 10.1002/mrm.22950] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2010] [Revised: 01/22/2011] [Accepted: 03/11/2011] [Indexed: 11/08/2022]
Abstract
Prospective right hemidiaphragm navigator (NAV) is commonly used in free-breathing coronary MRI. The NAV results in an increase in acquisition time to allow for resampling of the motion-corrupted k-space data. In this study, we are presenting a joint prospective-retrospective NAV motion compensation algorithm called compressed-sensing motion compensation (CosMo). The inner k-space region is acquired using a prospective NAV; for the outer k-space, a NAV is only used to reject the motion-corrupted data without reacquiring them. Subsequently, those unfilled k-space lines are retrospectively estimated using compressed sensing reconstruction. We imaged right coronary artery in nine healthy adult subjects. An undersampling probability map and sidelobe-to-peak ratio were calculated to study the pattern of undersampling, generated by NAV. Right coronary artery images were then retrospectively reconstructed using compressed-sensing motion compensation for gating windows between 3 and 10 mm and compared with the ones fully acquired within the gating windows. Qualitative imaging score and quantitative vessel sharpness were calculated for each reconstruction. The probability map and sidelobe-to-peak ratio show that the NAV generates a random undersampling k-space pattern. There were no statistically significant differences between the vessel sharpness and subjective score of the two reconstructions. Compressed-sensing motion compensation could be an alternative motion compensation technique for free-breathing coronary MRI that can be used to reduce scan time.
Collapse
Affiliation(s)
- Mehdi H. Moghari
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Mehmet Akçakaya
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Alan O'Connor
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
- School of Engineering and Applied Sciences, Harvard University
| | - Tamer A. Basha
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Michele Casanova
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | | | - Lois Goepfert
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Kraig V. Kissinger
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Beth Goddu
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Michael L. Chuang
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Vahid Tarokh
- School of Engineering and Applied Sciences, Harvard University
| | - Warren J. Manning
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
- Department of Radiology, Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| | - Reza Nezafat
- Department of Medicine (Cardiovascular Division), Harvard Medical School and Beth Israel Deaconess Medical Center, Boston, MA
| |
Collapse
|
7
|
Moghari MH, Hu P, Kissinger KV, Goddu B, Goepfert L, Ngo L, Manning WJ, Nezafat R. Subject-specific estimation of respiratory navigator tracking factor for free-breathing cardiovascular MR. Magn Reson Med 2011; 67:1665-72. [PMID: 22134885 DOI: 10.1002/mrm.23158] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Revised: 07/05/2011] [Accepted: 07/25/2011] [Indexed: 12/30/2022]
Abstract
A mean respiratory navigator tracking factor of 0.6 is commonly used to estimate the respiratory motion of the heart from the displacement of the right hemi-diaphragm. A constant tracking factor can generate significant residual error in estimation of the respiratory motion of the heart for the cases where the actual tracking factor highly deviates from 0.6. In this study, we implemented and evaluated a robust method to calculate a subject-specific tracking factor for free-breathing high resolution cardiac MR. The subject-specific tracking factor was calculated from two consecutive navigator signals placed on the right hemi-diaphragm and the basal left ventricle in a training phase. To verify the accuracy of the estimated subject-specific tracking factor, nineteen subjects were recruited for comparing the estimated tracking factor in real-time with an image-based tracking factor, calculated off-line. Subsequently, in seven adult subjects, whole-heart or targeted coronary artery MR images were acquired using the estimated subject-specific tracking factor and visually compared with those acquired using a constant (0.6) tracking factor. It was shown that the proposed method can accurately estimate the subject-specific tracking factor and improve the quality of coronary images when the subject-specific tracking factor differs from 0.6.
Collapse
Affiliation(s)
- Mehdi H Moghari
- Department of Medicine, Harvard Medical School, Beth Israel Deaconess Medical Center, Boston, Massachusetts 02215, USA
| | | | | | | | | | | | | | | |
Collapse
|
8
|
Barral JK, Santos JM, Damrose EJ, Fischbein NJ, Nishimura DG. Real-time motion correction for high-resolution larynx imaging. Magn Reson Med 2011; 66:174-9. [PMID: 21695722 DOI: 10.1002/mrm.22773] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2010] [Revised: 11/16/2010] [Accepted: 11/24/2010] [Indexed: 11/11/2022]
Abstract
Motion--both rigid-body and nonrigid--is the main limitation to in vivo, high-resolution larynx imaging. In this work, a new real-time motion compensation algorithm is introduced. Navigator data are processed in real time to compute the displacement information, and projections are corrected using phase modulation in k-space. Upon automatic feedback, the system immediately reacquires the data most heavily corrupted by nonrigid motion, i.e., the data whose corresponding projections could not be properly corrected. This algorithm overcomes the shortcomings of the so-called diminishing variance algorithm by combining it with navigator-based rigid-body motion correction. Because rigid-body motion correction is performed first, continual bulk motion no longer impedes nor prevents the convergence of the algorithm. Phantom experiments show that the algorithm properly corrects for translations and reacquires data corrupted by nonrigid motion. Larynx imaging was performed on healthy volunteers, and substantial reduction of motion artifacts caused by bulk shift, swallowing, and coughing was achieved.
Collapse
Affiliation(s)
- Joëlle K Barral
- Magnetic Resonance Systems Research Laboratory, Department of Electrical Engineering, Stanford University, Stanford, California, USA.
| | | | | | | | | |
Collapse
|
9
|
Liu J, Drangova M. Combination of multidimensional navigator echoes data from multielement RF coil. Magn Reson Med 2011; 64:1208-14. [PMID: 20564594 DOI: 10.1002/mrm.22496] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Until now, only one-dimensional navigator-echo techniques have been implemented with multielement RF coils. For the multidimensional navigator echoes, which extract six-degree of freedom motion information from the raw k-space data, an efficient raw data combination approach is needed. In this work, three combination approaches, including summation of the complex raw data, summation following phase alignment, and summation of the squares of the k-space magnitude profiles, were evaluated with the spherical navigator echoes (SNAV) technique. In vivo brain imaging experiments were used to quantify accuracy and precision and demonstrated that SNAVs acquired with an eight-channel head coil can determine the rotation and translation in range up to 10° and 20 mm with subdegree and submillimeter accuracy, respectively. Results from a 3D brain volume realignment experiment showed excellent agreement between baseline images and SNAV-aligned follow-up volumes.
Collapse
Affiliation(s)
- Junmin Liu
- Imaging Research Laboratories, Robarts Research Institute, Schulich School of Medicine & Dentistry, The University of Western Ontario, London, Ontario, Canada
| | | |
Collapse
|
10
|
Lai P, Bi X, Jerecic R, Li D. A respiratory self-gating technique with 3D-translation compensation for free-breathing whole-heart coronary MRA. Magn Reson Med 2009; 62:731-8. [PMID: 19526514 DOI: 10.1002/mrm.22058] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Respiratory motion remains a major challenge for robust coronary MR angiography (MRA). Diaphragmatic navigator (NAV) suffers from indirect measurement of heart position. Respiratory self-gating (RSG) approaches improve motion detection only in the head-feet direction, leaving motion in the other two dimensions unaccounted for. The purpose of this study was to extend conventional RSG (1D RSG) to RSG capable of 3D motion detection (3D RSG) by acquiring additional RSG projections with transverse-motion-encoding gradients. Simulation and volunteer studies were conducted to validate the effectiveness of this new method. Preliminary comparison was performed between coronary artery images reconstructed from the same datasets using different motion correction methods. Our simulation illustrates that a proper motion-encoding gradient and derivation method enable accurate 3D motion detection. Results from whole-heart coronary MRA show that 3D RSG can further reduce motion artifacts as compared to NAV and 1D RSG and enables use of larger gating windows for faster coronary imaging.
Collapse
Affiliation(s)
- Peng Lai
- Departments of Biomedical Engineering and Radiology, Northwestern University, Chicago, Illinois, USA
| | | | | | | |
Collapse
|
11
|
Abstract
Modern rapid magnetic resonance (MR) imaging techniques have led to widespread use of the modality in cardiac imaging. Despite this progress, many MR studies suffer from image degradation due to involuntary motion during the acquisition. This review describes the type and extent of the motion of the heart due to the cardiac and respiratory cycles, which create image artifacts. Methods of eliminating or reducing the problems caused by the cardiac cycle are discussed, including electrocardiogram gating, subject-specific acquisition windows, and section tracking. Similarly, for respiratory motion of the heart, techniques such as breath holding, respiratory gating, section tracking, phase-encoding ordering, subject-specific translational models, and a range of new techniques are considered.
Collapse
Affiliation(s)
- Andrew D Scott
- Cardiovascular Magnetic Resonance Unit, the Royal Brompton Hospital, London, England.
| | | | | |
Collapse
|
12
|
Dewan M, Hager GD, Lorenz CH. Image-based coronary tracking and beat-to-beat motion compensation: Feasibility for improving coronary MR angiography. Magn Reson Med 2008; 60:604-15. [DOI: 10.1002/mrm.21663] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
13
|
Stehning C, Boernert P, Nehrke K. Advances in Coronary MRA from Vessel Wall to Whole Heart Imaging. Magn Reson Med Sci 2007; 6:157-70. [PMID: 18037796 DOI: 10.2463/mrms.6.157] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
14
|
Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med 2005; 54:476-80. [PMID: 16032682 DOI: 10.1002/mrm.20557] [Citation(s) in RCA: 187] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free-breathing techniques with pencil-beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navigator position and the actual position of the heart may be adversely affected by hysteretic effects, navigator position, and temporal delays between the navigators and the image acquisition. In addition, irregular breathing patterns during navigator-gated scanning may result in low scan efficiency and prolonged scan time. The purpose of this study was to develop and implement a self-navigated, free-breathing, whole-heart 3D coronary MRI technique that would overcome these shortcomings and improve the ease-of-use of coronary MRI. A signal synchronous with respiration was extracted directly from the echoes acquired for imaging, and the motion information was used for retrospective, rigid-body, through-plane motion correction. The images obtained from the self-navigated reconstruction were compared with the results from conventional, prospective, pencil-beam navigator tracking. Image quality was improved in phantom studies using self-navigation, while equivalent results were obtained with both techniques in preliminary in vivo studies.
Collapse
Affiliation(s)
- C Stehning
- Institute of Biomedical Engineering, Karlsruhe, Germany
| | | | | | | | | |
Collapse
|
15
|
Ablitt NA, Gao J, Keegan J, Stegger L, Firmin DN, Yang GZ. Predictive cardiac motion modeling and correction with partial least squares regression. IEEE TRANSACTIONS ON MEDICAL IMAGING 2004; 23:1315-1324. [PMID: 15493698 DOI: 10.1109/tmi.2004.834622] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Respiratory-induced cardiac deformation is a major problem for high-resolution cardiac imaging. This paper presents a new technique for predictive cardiac motion modeling and correction, which uses partial least squares regression to extract intrinsic relationships between three-dimensional (3-D) cardiac deformation due to respiration and multiple one-dimensional real-time measurable surface intensity traces at chest or abdomen. Despite the fact that these surface intensity traces can be strongly coupled with each other but poorly correlated with respiratory-induced cardiac deformation, we demonstrate how they can be used to accurately predict cardiac motion through the extraction of latent variables of both the input and output of the model. The proposed method allows cross-modality reconstruction of patient specific models for dense motion field prediction, which after initial modeling can be used for real-time prospective motion tracking or correction. Detailed numerical issues related to the technique are discussed and the effectiveness of the motion and deformation modeling is validated with 3-D magnetic resonance data sets acquired from ten asymptomatic subjects covering the entire respiratory range.
Collapse
Affiliation(s)
- Nicholas A Ablitt
- Royal Society/Wolfson Foundation Medical Image Computing Laboratory, Department of Computing, Imperial College London, London SW7 2BZ, U.K
| | | | | | | | | | | |
Collapse
|
16
|
Abstract
This article reviews the current MR imaging literature with respect to ischemic heart disease and focuses on the clinical practicalities of cardiac MR imaging today.
Collapse
|
17
|
Nguyen TD, Nuval A, Mulukutla S, Wang Y. Direct monitoring of coronary artery motion with cardiac fat navigator echoes. Magn Reson Med 2003; 50:235-41. [PMID: 12876698 DOI: 10.1002/mrm.10550] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Navigator echoes (NAVs) provide an effective means of monitoring physiological motion in magnetic resonance imaging (MRI). Motion artifacts can be suppressed by adjusting the data acquisition accordingly. The standard pencil-beam NAV has been used to detect diaphragm motion; however, it does not monitor cardiac motion effectively. Here we report a navigator approach that directly measures coronary artery motion by exciting the surrounding epicardial fat and sampling the signal with a k-space trajectory sensitized to various motion parameters. The present preliminary human study demonstrates that superior-inferior (SI) respiratory motion of the coronary arteries detected by the cardiac fat NAV highly correlates with SI diaphragmatic motion detected by the pencil-beam NAV. In addition, the cardiac fat navigator gating is slightly more effective than the diaphragmatic navigator gating in suppressing motion artifacts in free-breathing 3D coronary MR angiography (MRA).
Collapse
Affiliation(s)
- Thanh D Nguyen
- MR Research Center, Department of Radiology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania 15213, USA
| | | | | | | |
Collapse
|
18
|
Yang PC, Meyer CH, Terashima M, Kaji S, McConnell MV, Macovski AL, Pauly JM, Nishimura DG, Hu BS. Spiral magnetic resonance coronary angiography with rapid real-time localization. J Am Coll Cardiol 2003; 41:1134-41. [PMID: 12679213 DOI: 10.1016/s0735-1097(03)00079-2] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
A spiral high-resolution coronary artery imaging sequence (SH) interfaced with real-time localization system (RT) has been developed. A clinical study of 40 patients suspected of coronary artery disease (CAD) was conducted. Segmented k-space acquisition techniques have dominated magnetic resonance coronary angiography (MRCA) over the last decade. Although a recent multicenter trial using this technique demonstrated encouraging results, the technique was hampered by low specificity. Spiral k-space acquisition had demonstrated several advantages for MRCA. Therefore, a first clinical trial implementing spiral high-resolution coronary imaging sequence with real-time localization (SH-RT) was performed.A clinical study of 40 patients suspected of CAD undergoing X-ray angiography was conducted to analyze the clinical reliability of this novel imaging system. The SH-RT had been designed to exploit the unique capability of two imaging sequences. The RT allowed a rapid localization of the coronary arteries. Then SH achieved multislice acquisition during a short breath-hold with submillimeter resolution. The MRCA data were analyzed for scan time, anatomic coverage, image quality, and accuracy in detecting CAD. In 40 subjects, SH achieved 0.7 to 0.9 mm resolution with 14-heartbeat breath-holds. Excellent or good image quality was achieved in 78% (263/337) of the coronary segments. Blinded consensus reading among three observers generated sensitivity of 76% and specificity of 91% in the detection of CAD compared with X-ray angiography. The MRCA imaging sequence implementing a novel spiral k-space acquisition technique enabled rapid and reliable imaging of the CAD in submillimeter resolution with short breath-holds.
Collapse
Affiliation(s)
- Phillip C Yang
- Division of Cardiovascular Medicine, Department of Medicine, Stanford, California 94305-5233, USA.
| | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Abstract
Magnetic resonance coronary angiography (MRCA) has witnessed tremendous technical advances over the past decade. Although high-quality images of the coronary arteries have been demonstrated, this imaging modality is not performed routinely today. The fundamental properties of the coronary arteries deterring noninvasive imaging are well known. This article provides an overview of the developmental efforts to overcome these challenges, and highlights key technical and clinical advances. The future prospect of MRCA depends on clinical implementation of the technique. In order to meet this challenge, the following issues must be addressed: contrast- and signal-to-noise ratio, temporal and spatial resolution, and scan protocol.
Collapse
Affiliation(s)
- Phillip C Yang
- Department of Medicine, Stanford University Medical Center, 300 Pasteur Drive, H2157, Stanford, CA 94305-5233, USA.
| | | | | | | |
Collapse
|
20
|
Wang Y, Stephens DN, O'Donnell M. Optimizing the beam pattern of a forward-viewing ring-annular ultrasound array for intravascular imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2002; 49:1652-1664. [PMID: 12546147 DOI: 10.1109/tuffc.2002.1159845] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Intravascular ultrasound (IVUS) imaging systems using circumferential arrays mounted on cardiac catheter tips fire beams orthogonal to the principal axis of the catheter. The system produces high resolution cross-sectional images but must be guided by conventional angioscopy. A real-time forward-viewing array, integrated into the same catheter, could greatly reduce radiation exposure by decreasing angiographic guidance. Unfortunately, the mounting requirement of a catheter guide wire prohibits a full-disk imaging aperture. Given only an annulus of array elements, prior theoretical investigations have only considered a circular ring of point transceivers and focusing strategies using all elements in the highly dense array, both impractical assumptions. In this paper, we consider a practical array geometry and signal processing architecture for a forward-viewing IVUS system. Our specific design uses a total of 210 transceiver firings with synthetic reconstruction for a given 3-D image frame. Simulation results demonstrate this design can achieve side-lobes under -40 dB for on-axis situations and under -30 dB for steering to the edge of a 80 degrees cone.
Collapse
Affiliation(s)
- Yao Wang
- Biomedical Engineering Department, University of Michigan, Ann Arbor, MI, USA.
| | | | | |
Collapse
|
21
|
McLeish K, Hill DLG, Atkinson D, Blackall JM, Razavi R. A study of the motion and deformation of the heart due to respiration. IEEE TRANSACTIONS ON MEDICAL IMAGING 2002; 21:1142-50. [PMID: 12564882 DOI: 10.1109/tmi.2002.804427] [Citation(s) in RCA: 157] [Impact Index Per Article: 7.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
This paper describes a quantitative assessment of respiratory motion of the heart and the construction of a model of respiratory motion. Three-dimensional magnetic resonance scans were acquired on eight normal volunteers and ten patients. The volunteers were imaged at multiple positions in the breathing cycle between full exhalation and full inhalation while holding their breath. The exhalation volume was segmented and used as a template to which the other volumes were registered using an intensity-based rigid registration algorithm followed by nonrigid registration. The patients were imaged at inhale and exhale only. The registration results were validated by visual assessment and consistency measurements indicating subvoxel registration accuracy. For all subjects, we assessed the nonrigid motion of the heart at the right coronary artery, right atrium, and left ventricle. We show that the rigid-body motion of the heart is primarily in the craniocaudal direction with smaller displacements in the right-left and anterior-posterior directions; this is in agreement with previous studies. Deformation was greatest for the free wall of the right atrium and the left ventricle; typical deformations were 3-4 mm with deformations of up to 7 mm observed in some subjects. Using the registration results, landmarks on the template surface were mapped to their correct positions through the breathing cycle. Principal component analysis produced a statistical model of the motion and deformation of the heart. We discuss how this model could be used to assist motion correction.
Collapse
Affiliation(s)
- Kate McLeish
- Division of Imaging Sciences, Guy's, King's, and St. Thomas' School of Medicine, Thomas Guy House. Guy's Hospital, SE1 9RT London, UK
| | | | | | | | | |
Collapse
|
22
|
Manke D, Nehrke K, Börnert P, Rösch P, Dössel O. Respiratory motion in coronary magnetic resonance angiography: a comparison of different motion models. J Magn Reson Imaging 2002; 15:661-71. [PMID: 12112516 DOI: 10.1002/jmri.10112] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022] Open
Abstract
PURPOSE To assess respiratory motion models for coronary magnetic resonance angiography (CMRA). In this study various motion models that describe the respiration-induced 3D displacements and deformations of the main coronary arteries were compared. MATERIALS AND METHODS Multiple high-resolution 3D coronary MR images were acquired in healthy volunteers using navigator-based respiratory gating, each depicting the coronary vessels at different respiratory motion states. In the images representing the different inspiratory states the displacements and deformations of the main coronary vessels with respect to the end-expiratory state were determined, by means of elastic registration. Several correction models (superior-inferior (SI) translation, 3D translation, and 3D affine transformation) were tested and compared with respect to their ability to map a selected inspiratory to the end-expiratory motion state. RESULTS 3D translation was found to be superior over SI translation, which is commonly used for prospective motion correction in CMRA. The 3D affine transformation was found to be the best correction model considered in this study. Furthermore, a large intersubject variability of the model parameters was observed. CONCLUSION The results of this study indicate that a patient-adapted 3D correction model (3D translation or better 3D affine) will considerably improve prospective motion correction in CMRA.
Collapse
Affiliation(s)
- Dirk Manke
- Institute of Biomedical Engineering, University of Karlsruhe, Karlsruhe, Germany.
| | | | | | | | | |
Collapse
|
23
|
Keegan J, Gatehouse P, Yang GZ, Firmin D. Coronary artery motion with the respiratory cycle during breath-holding and free-breathing: implications for slice-followed coronary artery imaging. Magn Reson Med 2002; 47:476-81. [PMID: 11870834 DOI: 10.1002/mrm.10069] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The displacement of the right coronary artery (RCA) origin with respiratory position was determined relative to the dome of the right hemidiaphragm in three orthogonal directions in eight healthy subjects. Both multiple breath-hold and free-breathing acquisitions were used, and motion correction factors for slice-following applications were determined. The correction factors for all three directions showed considerable intersubject variability. The mean superior-inferior factor was slightly less in free-breathing than in breath-holding (0.26 vs. 0.29, P = ns), and much less than the fixed value of 0.6 frequently implemented with slice-following. The anterior-posterior correction factors were uniformly low in free-breathing, and significantly less than those obtained from breath-holding (0.04 vs. 0.14, P <.05), while the mean left-right correction factors were approximately 0.1 for both. It is concluded that subject variability in correction factors, together with within-subject differences between breath-holding and free-breathing, is such that slice-following should be performed with subject-specific factors determined from free-breathing acquisitions.
Collapse
Affiliation(s)
- Jennifer Keegan
- Magnetic Resonance Unit, Royal Brompton and Harefield NHS Hospital Trust, London, UK.
| | | | | | | |
Collapse
|
24
|
Gatehouse PD, Keegan J, Yang GZ, Mohiaddin RH, Firmin DN. Tracking local volume 3D-echo-planar coronary artery imaging. Magn Reson Med 2001; 46:1031-6. [PMID: 11675659 DOI: 10.1002/mrm.1293] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Aiming for robust high-resolution free respiration coronary artery imaging, localized tracking volume selective 3D-EPI at spatial resolution 1.25 x 1.25 x 3 mm and temporal resolution 65 ms was evaluated in 14 normal subjects. Subject-specific motion tracking factors were measured between diaphragm navigator and coronary artery in S-I and A-P directions. Imaging was repeated with and without tracking, accepting 128 cardiac cycles over a 20-mm range from free breathing. Reference images with minimal respiratory motion (5-mm range) used LED-guided multiple breathholds. Depending on accurate motion measurement, coronary arteries were imaged with tracking, in a 20-mm range of free breathing, with increased scan efficiency but without significant loss of image quality compared to multiple breathhold imaging.
Collapse
Affiliation(s)
- P D Gatehouse
- Magnetic Resonance Unit, Royal Brompton Hospital and National Heart & Lung Institute, Imperial College, London, UK.
| | | | | | | | | |
Collapse
|
25
|
Nehrke K, Börnert P, Manke D, Böck JC. Free-breathing cardiac MR imaging: study of implications of respiratory motion--initial results. Radiology 2001; 220:810-5. [PMID: 11526286 DOI: 10.1148/radiol.2203010132] [Citation(s) in RCA: 124] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The respiratory motion of several anatomic regions (right hemidiaphragm, left ventricle of the heart, chest wall, abdominal wall) was investigated during free breathing in 10 healthy volunteers by using multinavigator technology and real-time magnetic resonance (MR) imaging. The respiratory motion shows hysteretic effects, which are strongly subject dependent and might have some effect on the quality of cardiac MR images.
Collapse
Affiliation(s)
- K Nehrke
- Department of Magnetic Resonance, Technical Systems Research Division, Philips Research Laboratories, Roentgenstrasse 24-26, D-22315 Hamburg, Germany.
| | | | | | | |
Collapse
|