1
|
Han Y, Kim DY, Woo J, Kim J. Glu-Ensemble: An ensemble deep learning framework for blood glucose forecasting in type 2 diabetes patients. Heliyon 2024; 10:e29030. [PMID: 38638954 PMCID: PMC11024573 DOI: 10.1016/j.heliyon.2024.e29030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 03/28/2024] [Accepted: 03/28/2024] [Indexed: 04/20/2024] Open
Abstract
Diabetes is a chronic metabolic disorder characterized by elevated blood glucose levels, posing significant health risks such as cardiovascular disease, and nerve, kidney, and eye damage. Effective management of blood glucose is essential for individuals with diabetes to mitigate these risks. This study introduces the Glu-Ensemble, a deep learning framework designed for precise blood glucose forecasting in patients with type 2 diabetes. Unlike other predictive models, Glu-Ensemble addresses challenges related to small sample sizes, data quality issues, reliance on strict statistical assumptions, and the complexity of models. It enhances prediction accuracy and model generalizability by utilizing larger datasets and reduces bias inherent in many predictive models. The framework's unified approach, as opposed to patient-specific models, eliminates the need for initial calibration time, facilitating immediate blood glucose predictions for new patients. The obtained results indicate that Glu-Ensemble surpasses traditional methods in accuracy, as measured by root mean square error, mean absolute error, and error grid analysis. The Glu-Ensemble framework emerges as a promising tool for blood glucose level prediction in type 2 diabetes patients, warranting further investigation in clinical settings for its practical application.
Collapse
Affiliation(s)
- Yechan Han
- Department of Medical Science, Soonchunhyang University, Asan, 31538, Republic of Korea
| | - Dae-Yeon Kim
- Department of Internal Medicine, Soonchunhyang University Cheonan Hospital, Cheonan, 31151, Republic of Korea
| | - Jiyoung Woo
- Department of AI and Big Data, Soonchunhyang University, Asan, 31538, Republic of Korea
| | - Jaeyun Kim
- Department of AI and Big Data, Soonchunhyang University, Asan, 31538, Republic of Korea
| |
Collapse
|
2
|
Xie J, Wang Q. A Data-Driven Personalized Model of Glucose Dynamics Taking Account of the Effects of Physical Activity for Type 1 Diabetes: An In Silico Study. J Biomech Eng 2020; 141:2703963. [PMID: 30458503 DOI: 10.1115/1.4041522] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2018] [Indexed: 12/17/2022]
Abstract
This paper aims to develop a data-driven model for glucose dynamics taking into account the effects of physical activity (PA) through a numerical study. It intends to investigate PA's immediate effect on insulin-independent glucose variation and PA's prolonged effect on insulin sensitivity. We proposed a nonlinear model with PA (NLPA), consisting of a linear regression of PA and a bilinear regression of insulin and PA. The model was identified and evaluated using data generated from a physiological PA-glucose model by Dalla Man et al. integrated with the uva/padova Simulator. Three metrics were computed to compare blood glucose (BG) predictions by NLPA, a linear model with PA (LPA), and a linear model with no PA (LOPA). For PA's immediate effect on glucose, NLPA and LPA showed 45-160% higher mean goodness of fit (FIT) than LOPA under 30 min-ahead glucose prediction (P < 0.05). For the prolonged PA effect on glucose, NLPA showed 87% higher FIT than LPA (P < 0.05) for simulations using no previous measurements. NLPA had 25-37% and 31-54% higher sensitivity in predicting postexercise hypoglycemia than LPA and LOPA, respectively. This study demonstrated the following qualitative trends: (1) for moderate-intensity exercise, accuracy of BG prediction was improved by explicitly accounting for PA's effect; and (2) accounting for PA's prolonged effect on insulin sensitivity can increase the chance of early prediction of postexercise hypoglycemia. Such observations will need to be further evaluated through human subjects in the future.
Collapse
Affiliation(s)
- Jinyu Xie
- Mechanical and Nuclear Engineering, 315 Leonhard Building, Penn State University, University Park, PA 16802 e-mail:
| | - Qian Wang
- Mem. ASME Professor Mechanical Engineering, 325 Leonhard Building, Penn State University, University Park, PA 16802 e-mail:
| |
Collapse
|
3
|
Resalat N, Hilts W, Youssef JE, Tyler N, Castle JR, Jacobs PG. Adaptive Control of an Artificial Pancreas Using Model Identification, Adaptive Postprandial Insulin Delivery, and Heart Rate and Accelerometry as Control Inputs. J Diabetes Sci Technol 2019; 13:1044-1053. [PMID: 31595784 PMCID: PMC6835177 DOI: 10.1177/1932296819881467] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
BACKGROUND People with type 1 diabetes (T1D) have varying sensitivities to insulin and also varying responses to meals and exercise. We introduce a new adaptive run-to-run model predictive control (MPC) algorithm that can be used to help people with T1D better manage their glucose levels using an artificial pancreas (AP). The algorithm adapts to individuals' different insulin sensitivities, glycemic response to meals, and adjustment during exercise as a continuous input during free-living conditions. METHODS A new insulin sensitivity adaptation (ISA) algorithm is presented that updates each patient's insulin sensitivity during nonmeal periods to reduce the error between the actual glucose levels and the process model. We further demonstrate how an adaptive learning postprandial hypoglycemia prevention algorithm (ALPHA) presented in the previous work can complement the ISA algorithm, and the algorithm can adapt in several days. We further show that if physical activity is incorporated as a continuous input (heart rate and accelerometry), performance is improved. The contribution of this work is the description of the ISA algorithm and the evaluation of how ISA, ALPHA, and incorporation of exercise metrics as a continuous input can impact glycemic control. RESULTS Incorporating ALPHA, ISA, and physical activity into the MPC improved glycemic outcome measures. The adaptive learning postprandial hypoglycemia prevention algorithm combined with ISA significantly reduced time spent in hypoglycemia by 71.7% and the total number of rescue carbs by 67.8% to 0.37% events/day/patient. Insulin sensitivity adaptation significantly reduced model-actual mismatch by 12.2% compared to an AP without ISA. Incorporating physical activity as a continuous input modestly improved time in the range 70 to 180 mg/dL during high physical activity days from 84.4% to 84.9% and reduced the percentage time in hypoglycemia by 23.8% from 2.1% to 1.6%. CONCLUSION Adapting postprandial insulin delivery, insulin sensitivity, and adapting to physical exercise in an MPC-based AP systems can improve glycemic outcomes.
Collapse
Affiliation(s)
- Navid Resalat
- Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Wade Hilts
- Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Joseph El Youssef
- Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center Oregon Health & Science University, Portland, OR, USA
| | - Nichole Tyler
- Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
| | - Jessica R. Castle
- Department of Medicine, Division of Endocrinology, Harold Schnitzer Diabetes Health Center Oregon Health & Science University, Portland, OR, USA
| | - Peter G. Jacobs
- Artificial Intelligence for Medical Systems (AIMS) Lab, Department of Biomedical Engineering, Oregon Health & Science University, Portland, OR, USA
- Peter G. Jacobs, PhD, Department of Biomedical Engineering, Oregon Health & Science University, 3303 SW Bond Ave, Mailstop: 13B, Portland, OR 97239, USA.
| |
Collapse
|
4
|
Hobbs N, Hajizadeh I, Rashid M, Turksoy K, Breton M, Cinar A. Improving Glucose Prediction Accuracy in Physically Active Adolescents With Type 1 Diabetes. J Diabetes Sci Technol 2019; 13:718-727. [PMID: 30654648 PMCID: PMC6610614 DOI: 10.1177/1932296818820550] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
BACKGROUND Physical activity presents a significant challenge for glycemic control in individuals with type 1 diabetes. As accurate glycemic predictions are key to successful automated decision-making systems (eg, artificial pancreas, AP), the inclusion of additional physiological variables in the estimation of the metabolic state may improve the glucose prediction accuracy during exercise. METHODS Predictor-based subspace identification is applied to a dynamic glucose prediction model including heart rate measurements along with variables representing the carbohydrate consumption and insulin boluses. To demonstrate the improvement in prediction ability due to the additional heart rate variable, the performance of the proposed modeling technique is evaluated with (SID-HR) and without heart rate (SID-2) as an additional input using experimental data involving adolescents at ski camp. Furthermore, the performance of the proposed approach is compared to that of the metabolic state observer (MSO) model currently used in the University of Virginia AP algorithm. RESULTS The addition of heart rate in the subspace-based model (SID-HR) yields a statistically significant improvement in the root-mean-square error compared to the SID-2 model (P < .001) and the standard MSO (P < .001). Furthermore, the SID-HR model performed favorably in comparison to the SID-2 and MSO models after accounting for its increased complexity. CONCLUSIONS Directly considering the effects of physical activity levels on glycemic dynamics through the inclusion of heart rate as an additional input variable in the glucose dynamics model improves the glucose prediction accuracy. The proposed methodology could improve exercise-informed model-based predictive control algorithms in artificial pancreas systems.
Collapse
Affiliation(s)
- Nicole Hobbs
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Iman Hajizadeh
- Department of Chemical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Mudassir Rashid
- Department of Chemical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Kamuran Turksoy
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
| | - Marc Breton
- Center for Diabetes Technology,
University of Virginia, Charlottesville, VA, USA
| | - Ali Cinar
- Department of Biomedical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
- Department of Chemical Engineering,
Illinois Institute of Technology, Chicago, IL, USA
- Ali Cinar, PhD, Illinois Institute of
Technology, Department of Chemical and Biological Engineering, 10 W 33rd St,
Chicago, IL 60616, USA.
| |
Collapse
|
5
|
Colmegna PH, Sánchez-Peña RS, Gondhalekar R, Dassau E, Doyle FJ. Reducing Glucose Variability Due to Meals and Postprandial Exercise in T1DM Using Switched LPV Control: In Silico Studies. J Diabetes Sci Technol 2016; 10:744-53. [PMID: 27022097 PMCID: PMC5038547 DOI: 10.1177/1932296816638857] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND Time-varying dynamics is one of the main issues for achieving safe blood glucose control in type 1 diabetes mellitus (T1DM) patients. In addition, the typical disturbances considered for controller design are meals, which increase the glucose level, and physical activity (PA), which increases the subject's sensitivity to insulin. In previous works the authors have applied a linear parameter-varying (LPV) control technique to manage unannounced meals. METHODS A switched LPV controller that switches between 3 LPV controllers, each with a different level of aggressiveness, is designed to further cope with both unannounced meals and postprandial PA. Thus, the proposed control strategy has a "standard" mode, an "aggressive" mode, and a "conservative" mode. The "standard" mode is designed to be applied most of the time, while the "aggressive" mode is designed to deal only with hyperglycemia situations. On the other hand, the "conservative" mode is focused on postprandial PA control. RESULTS An ad hoc simulator has been developed to test the proposed controller. This simulator is based on the distribution version of the UVA/Padova model and includes the effect of PA based on Schiavon.(1) The test results obtained when using this simulator indicate that the proposed control law substantially reduces the risk of hypoglycemia with the conservative strategy, while the risk of hyperglycemia is scarcely affected. CONCLUSIONS It is demonstrated that the announcement, or anticipation, of exercise is indispensable for letting a mono-hormonal artificial pancreas deal with the consequences of postprandial PA. In view of this the proposed controller allows switching into a conservative mode when notified of PA by the user.
Collapse
Affiliation(s)
- Patricio H Colmegna
- National Scientific and Technical Research Council, Buenos Aires, Argentina Departamento de Ciencia y Tecnología, Universidad Nacional de Quilmes, Buenos Aires, Argentina
| | - Ricardo S Sánchez-Peña
- National Scientific and Technical Research Council, Buenos Aires, Argentina Centro de Sistemas y Control, Instituto Tecnológico de Buenos Aires, Buenos Aires, Argentina
| | - Ravi Gondhalekar
- Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA
| | - Eyal Dassau
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| | - Francis J Doyle
- John A. Paulson School of Engineering & Applied Sciences, Harvard University, Cambridge, MA, USA
| |
Collapse
|