1
|
Capuano E, Regazzoni F, Maines M, Fornara S, Locatelli V, Catanzariti D, Stella S, Nobile F, Greco MD, Vergara C. Personalized computational electro-mechanics simulations to optimize cardiac resynchronization therapy. Biomech Model Mechanobiol 2024; 23:1977-2004. [PMID: 39192164 PMCID: PMC11554892 DOI: 10.1007/s10237-024-01878-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 07/12/2024] [Indexed: 08/29/2024]
Abstract
In this study, we present a computational framework designed to evaluate virtual scenarios of cardiac resynchronization therapy (CRT) and compare their effectiveness based on relevant clinical biomarkers. Our approach involves electro-mechanical numerical simulations personalized, for patients with left bundle branch block, by means of a calibration obtained using data from Electro-Anatomical Mapping System (EAMS) measures acquired by cardiologists during the CRT procedure, as well as ventricular pressures and volumes, both obtained pre-implantation. We validate the calibration by using EAMS data coming from right pacing conditions. Three patients with fibrosis and three without are considered to explore various conditions. Our virtual scenarios consist of personalized numerical experiments, incorporating different positions of the left electrode along reconstructed epicardial veins; different locations of the right electrode; different ventriculo-ventricular delays. The aim is to offer a comprehensive tool capable of optimizing CRT efficiency for individual patients. We provide preliminary answers on optimal electrode placement and delay, by computing some relevant biomarkers such as d P / d t max , ejection fraction, stroke work. From our numerical experiments, we found that the latest activated segment during sinus rhythm is an effective choice for the non-fibrotic cases for the location of the left electrode. Also, our results showed that the activation of the right electrode before the left one seems to improve the CRT performance for the non-fibrotic cases. Last, we found that the CRT performance seems to improve by positioning the right electrode halfway between the base and the apex. This work is on the line of computational works for the study of CRT and introduces new features in the field, such as the presence of the epicardial veins and the movement of the right electrode. All these studies from the different research groups can in future synergistically flow together in the development of a tool which clinicians could use during the procedure to have quantitative information about the patient's propagation in different scenarios.
Collapse
Affiliation(s)
- Emilia Capuano
- MOX, Dipartimento di Mathematica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy
| | - Francesco Regazzoni
- MOX, Dipartimento di Mathematica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy
| | - Massimiliano Maines
- Cardiology department, S.M. del Carmine Hospital, APSS, Corso Verona, 4, Rovereto, 38068, Trento, Italy
| | - Silvia Fornara
- LABS, Dipartimento di Chimica, Materiali e Ingegneria Chimica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy
| | - Vanessa Locatelli
- LABS, Dipartimento di Chimica, Materiali e Ingegneria Chimica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy
| | - Domenico Catanzariti
- Cardiology department, S.M. del Carmine Hospital, APSS, Corso Verona, 4, Rovereto, 38068, Trento, Italy
| | - Simone Stella
- MOX, Dipartimento di Mathematica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy
| | - Fabio Nobile
- Institute of Mathematics, École Polytechnique Fédérale de Lausanne, Station 8, Av. Piccard, CH-1015, Lausanne, Switzerland
| | - Maurizio Del Greco
- Cardiology department, S.M. del Carmine Hospital, APSS, Corso Verona, 4, Rovereto, 38068, Trento, Italy
| | - Christian Vergara
- LABS, Dipartimento di Chimica, Materiali e Ingegneria Chimica, Politecnico di Milano, Piazza Leonardo da Vinci, 32, 201333, Milan, Italy.
| |
Collapse
|
2
|
Liao S, Simpson B, Neidlin M, Kaufmann TAS, Li Z, Woodruff MA, Gregory SD. Numerical prediction of thrombus risk in an anatomically dilated left ventricle: the effect of inflow cannula designs. Biomed Eng Online 2016; 15:136. [PMID: 28155674 PMCID: PMC5260141 DOI: 10.1186/s12938-016-0262-2] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Implantation of a rotary blood pump (RBP) can cause non-physiological flow fields in the left ventricle (LV) which may trigger thrombosis. Different inflow cannula geometry can affect LV flow fields. The aim of this study was to determine the effect of inflow cannula geometry on intraventricular flow under full LV support in a patient specific model. METHODS Computed tomography angiography imaging of the LV was performed on a RBP candidate to develop a patient-specific model. Five inflow cannulae were evaluated, which were modelled on those used clinically or under development. The inflow cannulae are described as a crown like tip, thin walled tubular tip, large filleted tip, trumpet like tip and an inferiorly flared cannula. Placement of the inflow cannula was at the LV apex with the central axis intersecting the centre of the mitral valve. Full support was simulated by prescribing 5 l/min across the mitral valve. Thrombus risk was evaluated by identifying regions of stagnation. Rate of LV washout was assessed using a volume of fluid model. Relative haemolysis index and blood residence time was calculated using an Eulerian approach. RESULTS The inferiorly flared inflow cannula had the lowest thrombus risk due to low stagnation volumes. All cannulae had similar rates of LV washout and blood residence time. The crown like tip and thin walled tubular tip resulted in relatively higher blood damage indices within the LV. CONCLUSION Changes in intraventricular flow due to variances in cannula geometry resulted in different stagnation volumes. Cannula geometry does not appreciably affect LV washout rates and blood residence time. The patient specific, full support computational fluid dynamic model provided a repeatable platform to investigate the effects of inflow cannula geometry on intraventricular flow.
Collapse
Affiliation(s)
- Sam Liao
- Innovative Cardiovascular Engineering and Technology Laboratory (ICETLAB), Critical Care Research Group, The Prince Charles Hospital, Chermside, QLD 4032 Australia
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), Kelvin Grove, QLD 4059 Australia
| | - Benjamin Simpson
- School of Engineering, Griffith University, Southport, QLD 4215 Australia
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Tim A. S. Kaufmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Zhiyong Li
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), Kelvin Grove, QLD 4059 Australia
| | - Maria A. Woodruff
- Institute of Health and Biomedical Innovation (IHBI), Queensland University of Technology (QUT), Kelvin Grove, QLD 4059 Australia
| | - Shaun D. Gregory
- Innovative Cardiovascular Engineering and Technology Laboratory (ICETLAB), Critical Care Research Group, The Prince Charles Hospital, Chermside, QLD 4032 Australia
- School of Engineering, Griffith University, Southport, QLD 4215 Australia
| |
Collapse
|
3
|
Chabiniok R, Wang VY, Hadjicharalambous M, Asner L, Lee J, Sermesant M, Kuhl E, Young AA, Moireau P, Nash MP, Chapelle D, Nordsletten DA. Multiphysics and multiscale modelling, data-model fusion and integration of organ physiology in the clinic: ventricular cardiac mechanics. Interface Focus 2016; 6:20150083. [PMID: 27051509 PMCID: PMC4759748 DOI: 10.1098/rsfs.2015.0083] [Citation(s) in RCA: 139] [Impact Index Per Article: 15.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
With heart and cardiovascular diseases continually challenging healthcare systems worldwide, translating basic research on cardiac (patho)physiology into clinical care is essential. Exacerbating this already extensive challenge is the complexity of the heart, relying on its hierarchical structure and function to maintain cardiovascular flow. Computational modelling has been proposed and actively pursued as a tool for accelerating research and translation. Allowing exploration of the relationships between physics, multiscale mechanisms and function, computational modelling provides a platform for improving our understanding of the heart. Further integration of experimental and clinical data through data assimilation and parameter estimation techniques is bringing computational models closer to use in routine clinical practice. This article reviews developments in computational cardiac modelling and how their integration with medical imaging data is providing new pathways for translational cardiac modelling.
Collapse
Affiliation(s)
- Radomir Chabiniok
- Division of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas’ Hospital, London SE1 7EH, UK
- Inria and Paris-Saclay University, Bâtiment Alan Turing, 1 rue Honoré d'Estienne d'Orves, Campus de l'Ecole Polytechnique, Palaiseau 91120, France
| | - Vicky Y. Wang
- Auckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland, New Zealand
| | - Myrianthi Hadjicharalambous
- Division of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas’ Hospital, London SE1 7EH, UK
| | - Liya Asner
- Division of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas’ Hospital, London SE1 7EH, UK
| | - Jack Lee
- Division of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas’ Hospital, London SE1 7EH, UK
| | - Maxime Sermesant
- Inria, Asclepios team, 2004 route des Lucioles BP 93, Sophia Antipolis Cedex 06902, France
| | - Ellen Kuhl
- Departments of Mechanical Engineering, Bioengineering, and Cardiothoracic Surgery, Stanford University, 496 Lomita Mall, Durand 217, Stanford, CA 94306, USA
| | - Alistair A. Young
- Auckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland, New Zealand
| | - Philippe Moireau
- Inria and Paris-Saclay University, Bâtiment Alan Turing, 1 rue Honoré d'Estienne d'Orves, Campus de l'Ecole Polytechnique, Palaiseau 91120, France
| | - Martyn P. Nash
- Auckland Bioengineering Institute, University of Auckland, 70 Symonds Street, Auckland, New Zealand
- Department of Engineering Science, University of Auckland, 70 Symonds Street, Auckland, New Zealand
| | - Dominique Chapelle
- Inria and Paris-Saclay University, Bâtiment Alan Turing, 1 rue Honoré d'Estienne d'Orves, Campus de l'Ecole Polytechnique, Palaiseau 91120, France
| | - David A. Nordsletten
- Division of Imaging Sciences and Biomedical Engineering, King's College London, St Thomas’ Hospital, London SE1 7EH, UK
| |
Collapse
|