Zarrini-Monfared Z, Parvaresh M, Mirbagheri MM. T 1 Thermometry for Deep Brain Stimulation Applications: A Comparison between Rapid Gradient Echo Sequences. J Biomed Phys Eng 2024; 14:569-578. [PMID: 39726884 PMCID: PMC11668934 DOI: 10.31661/jbpe.v0i0.2210-1546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2022] [Accepted: 12/15/2022] [Indexed: 12/28/2024]
Abstract
Background T1 thermometry is considered a straight method for the safety monitoring of patients with deep brain stimulation (DBS) electrodes against radiofrequency-induced heating during Magnetic Resonance Imaging (MRI), requiring different sequences and methods. Objective This study aimed to compare two T1 thermometry methods and two low specific absorption rate (SAR) imaging sequences in terms of the output image quality. Material and Methods In this experimental study, a gel phantom was prepared, resembling the brain tissue properties with a copper wire inside. Two types of rapid gradient echo sequences, namely radiofrequency-spoiled and balanced steady-state free precession (bSSFP) sequences, were used. T1 thermometry was performed by either T1-weighted images with a high SAR sequence to increase heating around the wire or T1 mapping methods. Results The balanced steady-state free precession (bSSFP) sequence provided higher image quality in terms of spatial resolution (1×1×1.5 mm3 compared with 1×1×3 mm3) at a shorter acquisition time. The susceptibility artifact was also less pronounced for the bSSFP sequence compared with the radiofrequency-spoiled sequence. A temperature increase, of up to 8 ℃, was estimated using a high SAR sequence. The estimated change in temperature was reduced when using the T1 mapping method. Conclusion Heating induced during MRI of implanted electrodes could be estimated using high-resolution T1 maps obtained from inversion recovery bSSFP sequence. Such a method gives a direct estimation of heating during the imaging sequence, which is highly desirable for safe MRI of DBS patients.
Collapse
Affiliation(s)
- Zinat Zarrini-Monfared
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Mansour Parvaresh
- Department of Neurosurgery, Hazrat Rasool Hospital, Iran University of Medical Sciences, Tehran, Iran
| | - Mehdi Mohammad Mirbagheri
- Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
- Department of Physical Medicine and Rehabilitation, Northwestern University, USA
| |
Collapse
|
2
|
Esplin N, Kusyk D, Jeong SW, Elhamdani S, Abdel Aziz K, Webb A, Angle C, Whiting D, Tomycz ND. Movement disorder Deep brain stimulation Hybridization: Patient and caregiver outcomes. Clin Park Relat Disord 2024; 10:100234. [PMID: 38292816 PMCID: PMC10827541 DOI: 10.1016/j.prdoa.2024.100234] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2023] [Revised: 11/11/2023] [Accepted: 01/05/2024] [Indexed: 02/01/2024] Open
Abstract
Background and Objectives Deep brain stimulation (DBS) is a well-established surgical treatment for certain movement disorders and involves the implantation of brain electrodes connected to implantable pulse generators (IPGs). As more device manufacturers have entered the market, some IPG technology has been designed to be compatible with brain electrodes from other manufacturers, which has facilitated the hybridization of implant technology. The aim of this study was to assess the benefits of hybridization of non-rechargeable, constant voltage IPGs to rechargeable, constant current IPGs. Methods A list of DBS movement disorder patients who had their non-rechargeable, constant voltage IPGs replaced with rechargeable, constant current IPGs from a different manufacturer was compiled. Structured surveys of these patients, and their caregivers when applicable, were undertaken to determine both patient and caregiver satisfaction in this DBS hybridization strategy. Results Eighteen patients met inclusion criteria and twelve patients or their caregivers completed the structured survey (67% response rate). Nine patients had Parkinson's disease (75%), three had essential tremor (25%). Nine (75%) were converted from bilateral single-channel IPGs, and three (25%) were converted from a unilateral dual-channel IPGs. Overall, 92% of patients and caregivers surveyed reported improvement or no change in their symptoms, 92% reported a decrease or no change in their medication requirements, and 92% report they are satisfied or very satisfied with their IPG hybridization and would recommend the surgery to similar patients. There were no immediate surgical complications. Conclusion In this series of movement disorder DBS patients, surgery was safe and patient and caregiver satisfaction were high with a hybridization of non-rechargeable, constant voltage IPGs to rechargeable, constant current IPGs.
Collapse
Affiliation(s)
- Nathan Esplin
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Dorian Kusyk
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Seung W Jeong
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Shahed Elhamdani
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Khaled Abdel Aziz
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Amanda Webb
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Cindy Angle
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Donald Whiting
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| | - Nestor D. Tomycz
- Department of Neurosurgery, Allegheny Health Network, 320 East North Ave, Pittsburgh PA 15212, United States
| |
Collapse
|
3
|
Vu J, Bhusal B, Nguyen BT, Sanpitak P, Nowac E, Pilitsis J, Rosenow J, Golestanirad L. A comparative study of RF heating of deep brain stimulation devices in vertical vs. horizontal MRI systems. PLoS One 2022; 17:e0278187. [PMID: 36490249 PMCID: PMC9733854 DOI: 10.1371/journal.pone.0278187] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Accepted: 11/11/2022] [Indexed: 12/13/2022] Open
Abstract
The majority of studies that assess magnetic resonance imaging (MRI) induced radiofrequency (RF) heating of the tissue when active electronic implants are present have been performed in horizontal, closed-bore MRI systems. Vertical, open-bore MRI systems have a 90° rotated magnet and a fundamentally different RF coil geometry, thus generating a substantially different RF field distribution inside the body. Little is known about the RF heating of elongated implants such as deep brain stimulation (DBS) devices in this class of scanners. Here, we conducted the first large-scale experimental study investigating whether RF heating was significantly different in a 1.2 T vertical field MRI scanner (Oasis, Fujifilm Healthcare) compared to a 1.5 T horizontal field MRI scanner (Aera, Siemens Healthineers). A commercial DBS device mimicking 30 realistic patient-derived lead trajectories extracted from postoperative computed tomography images of patients who underwent DBS surgery at our institution was implanted in a multi-material, anthropomorphic phantom. RF heating around the DBS lead was measured during four minutes of high-SAR RF exposure. Additionally, we performed electromagnetic simulations with leads of various internal structures to examine this effect on RF heating. When controlling for RMS B1+, the temperature increase around the DBS lead-tip was significantly lower in the vertical scanner compared to the horizontal scanner (0.33 ± 0.24°C vs. 4.19 ± 2.29°C). Electromagnetic simulations demonstrated up to a 17-fold reduction in the maximum of 0.1g-averaged SAR in the tissue surrounding the lead-tip in the vertical scanner compared to the horizontal scanner. Results were consistent across leads with straight and helical internal wires. Radiofrequency heating and power deposition around the DBS lead-tip were substantially lower in the 1.2 T vertical scanner compared to the 1.5 T horizontal scanner. Simulations with different lead structures suggest that the results may extend to leads from other manufacturers.
Collapse
Affiliation(s)
- Jasmine Vu
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, United States of America
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Bhumi Bhusal
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Bach T. Nguyen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Pia Sanpitak
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, United States of America
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Elizabeth Nowac
- Illinois Bone and Joint Institute (IBJI), Wilmette, Illinois, United States of America
| | - Julie Pilitsis
- Department of Neurosciences & Experimental Therapeutics, Albany Medical College, Albany, New York, United States of America
| | - Joshua Rosenow
- Department of Neurosurgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
| | - Laleh Golestanirad
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, United States of America
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, United States of America
- * E-mail:
| |
Collapse
|
4
|
Vu J, Nguyen BT, Bhusal B, Baraboo J, Rosenow J, Bagci U, Bright MG, Golestanirad L. Machine learning-based prediction of MRI-induced power absorption in the tissue in patients with simplified deep brain stimulation lead models. IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY 2021; 63:1757-1766. [PMID: 34898696 PMCID: PMC8654205 DOI: 10.1109/temc.2021.3106872] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Interaction of an active electronic implant such as a deep brain stimulation (DBS) system and MRI RF fields can induce excessive tissue heating, limiting MRI accessibility. Efforts to quantify RF heating mostly rely on electromagnetic (EM) simulations to assess individualized specific absorption rate (SAR), but such simulations require extensive computational resources. Here, we investigate if a predictive model using machine learning (ML) can predict the local SAR in the tissue around tips of implanted leads from the distribution of the tangential component of the MRI incident electric field, Etan. A dataset of 260 unique patient-derived and artificial DBS lead trajectories was constructed, and the 1 g-averaged SAR, 1gSARmax, at the lead-tip during 1.5 T MRI was determined by EM simulations. Etan values along each lead's trajectory and the simulated SAR values were used to train and test the ML algorithm. The resulting predictions of the ML algorithm indicated that the distribution of Etan could effectively predict 1gSARmax at the DBS lead-tip (R = 0.82). Our results indicate that ML has the potential to provide a fast method for predicting MR-induced power absorption in the tissue around tips of implanted leads such as those in active electronic medical devices.
Collapse
Affiliation(s)
- Jasmine Vu
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| | - Bach T Nguyen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Bhumi Bhusal
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Justin Baraboo
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| | - Joshua Rosenow
- Department of Neurosurgery, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Ulas Bagci
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, IL, USA
| | - Molly G Bright
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| | - Laleh Golestanirad
- Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, IL, USA
| |
Collapse
|
5
|
Bhusal B, Stockmann J, Guerin B, Mareyam A, Kirsch J, Wald LL, Nolt MJ, Rosenow J, Lopez-Rosado R, Elahi B, Golestanirad L. Safety and image quality at 7T MRI for deep brain stimulation systems: Ex vivo study with lead-only and full-systems. PLoS One 2021; 16:e0257077. [PMID: 34492090 PMCID: PMC8423254 DOI: 10.1371/journal.pone.0257077] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2020] [Accepted: 08/23/2021] [Indexed: 11/19/2022] Open
Abstract
Ultra-high field MRI at 7 T can produce much better visualization of sub-cortical structures compared to lower field, which can greatly help target verification as well as overall treatment monitoring for patients with deep brain stimulation (DBS) implants. However, use of 7 T MRI for such patients is currently contra-indicated by guidelines from the device manufacturers due to the safety issues. The aim of this study was to provide an assessment of safety and image quality of ultra-high field magnetic resonance imaging at 7 T in patients with deep brain stimulation implants. We performed experiments with both lead-only and complete DBS systems implanted in anthropomorphic phantoms. RF heating was measured for 43 unique patient-derived device configurations. Magnetic force measurements were performed according to ASTM F2052 test method, and device integrity was assessed before and after experiments. Finally, we assessed electrode artifact in a cadaveric brain implanted with an isolated DBS lead. RF heating remained below 2°C, similar to a fever, with the 95% confidence interval between 0.38°C-0.52°C. Magnetic forces were well below forces imposed by gravity, and thus not a source of concern. No device malfunctioning was observed due to interference from MRI fields. Electrode artifact was most noticeable on MPRAGE and T2*GRE sequences, while it was minimized on T2-TSE images. Our work provides the safety assessment of ultra-high field MRI at 7 T in patients with DBS implants. Our results suggest that 7 T MRI may be performed safely in patients with DBS implants for specific implant models and MRI hardware.
Collapse
Affiliation(s)
- Bhumi Bhusal
- Department of Radiology, Northwestern University, Chicago, IL, United States of America
| | - Jason Stockmann
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Bastien Guerin
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Azma Mareyam
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - John Kirsch
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Lawrence L. Wald
- Department of Radiology, Harvard Medical School, Boston, MA, United States of America
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, MA, United States of America
| | - Mark J. Nolt
- Department of Neurosurgery, Northwestern University, Chicago, IL, United States of America
| | - Joshua Rosenow
- Department of Neurosurgery, Northwestern University, Chicago, IL, United States of America
| | - Roberto Lopez-Rosado
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL, United States of America
| | - Behzad Elahi
- Department of Physical Therapy and Human Movement Sciences, Northwestern University, Chicago, IL, United States of America
| | - Laleh Golestanirad
- Department of Radiology, Northwestern University, Chicago, IL, United States of America
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, United States of America
| |
Collapse
|
6
|
Kazemivalipour E, Bhusal B, Vu J, Lin S, Nguyen BT, Kirsch J, Nowac E, Pilitsis J, Rosenow J, Atalar E, Golestanirad L. Vertical open-bore MRI scanners generate significantly less radiofrequency heating around implanted leads: A study of deep brain stimulation implants in 1.2T OASIS scanners versus 1.5T horizontal systems. Magn Reson Med 2021; 86:1560-1572. [PMID: 33961301 DOI: 10.1002/mrm.28818] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2021] [Revised: 04/05/2021] [Accepted: 04/07/2021] [Indexed: 12/17/2022]
Abstract
PURPOSE Patients with active implants such as deep brain stimulation (DBS) devices are often denied access to MRI due to safety concerns associated with the radiofrequency (RF) heating of their electrodes. The majority of studies on RF heating of conductive implants have been performed in horizontal close-bore MRI scanners. Vertical MRI scanners which have a 90° rotated transmit coil generate fundamentally different electric and magnetic field distributions, yet very little is known about RF heating of implants in this class of scanners. We performed numerical simulations as well as phantom experiments to compare RF heating of DBS implants in a 1.2T vertical scanner (OASIS, Hitachi) compared to a 1.5T horizontal scanner (Aera, Siemens). METHODS Simulations were performed on 90 lead models created from post-operative CT images of patients with DBS implants. Experiments were performed with wires and commercial DBS devices implanted in an anthropomorphic phantom. RESULTS We found significant reduction of 0.1 g-averaged specific absorption rate (30-fold, P < 1 × 10-5 ) and RF heating (9-fold, P < .026) in the 1.2T vertical scanner compared to the 1.5T conventional scanner. CONCLUSION Vertical MRI scanners appear to generate lower RF heating around DBS leads, providing potentially heightened safety or the flexibility to use sequences with higher power levels than on conventional systems.
Collapse
Affiliation(s)
- Ehsan Kazemivalipour
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Bhumi Bhusal
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Jasmine Vu
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| | - Stella Lin
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Bach Thanh Nguyen
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - John Kirsch
- A. A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Boston, Massachusetts, USA
| | - Elizabeth Nowac
- Department of Neurosurgery, Albany Medical Center, Albany, New York, USA
| | - Julie Pilitsis
- Illinois Bone and Joint Institute (IBJI), Wilmette, Illinois, USA
| | - Joshua Rosenow
- Department of Neurological Surgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| | - Ergin Atalar
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Laleh Golestanirad
- Department of Radiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA.,Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois, USA
| |
Collapse
|