1
|
Hamdan PNF, Hamzaid NA, Hasnan N, Abd Razak NA, Razman R, Usman J. Effects of releasing ankle joint during electrically evoked cycling in persons with motor complete spinal cord injury. Sci Rep 2024; 14:6451. [PMID: 38499594 PMCID: PMC10948841 DOI: 10.1038/s41598-024-56955-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2022] [Accepted: 03/13/2024] [Indexed: 03/20/2024] Open
Abstract
Literature has shown that simulated power production during conventional functional electrical stimulation (FES) cycling was improved by 14% by releasing the ankle joint from a fixed ankle setup and with the stimulation of the tibialis anterior and triceps surae. This study aims to investigate the effect of releasing the ankle joint on the pedal power production during FES cycling in persons with spinal cord injury (SCI). Seven persons with motor complete SCI participated in this study. All participants performed 1 min of fixed-ankle and 1 min of free-ankle FES cycling with two stimulation modes. In mode 1 participants performed FES-evoked cycling with the stimulation of quadriceps and hamstring muscles only (QH stimulation), while Mode 2 had stimulation of quadriceps, hamstring, tibialis anterior, and triceps surae muscles (QHT stimulation). The order of each trial was randomized in each participant. Free-ankle FES cycling offered greater ankle plantar- and dorsiflexion movement at specific slices of 20° crank angle intervals compared to fixed-ankle. There were significant differences in the mean and peak normalized pedal power outputs (POs) [F(1,500) = 14.03, p < 0.01 and F(1,500) = 7.111, p = 0.008, respectively] between fixed- and free-ankle QH stimulation, and fixed- and free-ankle QHT stimulation. Fixed-ankle QHT stimulation elevated the peak normalized pedal PO by 14.5% more than free-ankle QH stimulation. Releasing the ankle joint while providing no stimulation to the triceps surae and tibialis anterior reduces power output. The findings of this study suggest that QHT stimulation is necessary during free-ankle FES cycling to maintain power production as fixed-ankle.
Collapse
Affiliation(s)
- Puteri Nur Farhana Hamdan
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Nur Azah Hamzaid
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
- Department of Biomedical Engineering, Faculty of Engineering, Centre of Applied Biomechanics, Universiti Malaya, 50603, Kuala Lumpur, Malaysia.
| | - Nazirah Hasnan
- Department of Rehabilitation Medicine, Faculty of Medicine, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Nasrul Anuar Abd Razak
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Rizal Razman
- Centre for Sport & Exercise Sciences, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| | - Juliana Usman
- Department of Biomedical Engineering, Faculty of Engineering, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
- Department of Biomedical Engineering, Faculty of Engineering, Centre of Applied Biomechanics, Universiti Malaya, 50603, Kuala Lumpur, Malaysia
| |
Collapse
|
2
|
Schmoll M, Le Guillou R, Fattal C, Coste CA. OIDA: An optimal interval detection algorithm for automatized determination of stimulation patterns for FES-Cycling in individuals with SCI. J Neuroeng Rehabil 2022; 19:39. [PMID: 35422040 PMCID: PMC9008993 DOI: 10.1186/s12984-022-01018-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2021] [Accepted: 04/05/2022] [Indexed: 11/24/2022] Open
Abstract
Background FES-Cycling is an exciting recreational activity, which allows certain individuals after spinal cord injury or stroke to exercise their paralyzed muscles. The key for a successful application is to activate the right muscles at the right time. Methods While a stimulation pattern is usually determined empirically, we propose an approach using the torque feedback provided by a commercially available crank power-meter installed on a standard trike modified for FES-Cycling. By analysing the difference between active (with stimulation) and passive (without stimulation) torques along a full pedalling cycle, it is possible to differentiate between contributing and resisting phases for a particular muscle group. In this article we present an algorithm for the detection of optimal stimulation intervals and demonstrate its functionality, bilaterally for the quadriceps and hamstring muscles, in one subject with complete SCI on a home trainer. Stimulation patterns were automatically determined for two sensor input modalities: the crank-angle and a normalized thigh-angle (i.e. cycling phase, measured via inertial measurement units). In contrast to previous studies detecting automatic stimulation intervals on motorised ergo-cycles, our approach does not rely on a constant angular velocity provided by a motor, thus being applicable to the domain of mobile FES-Cycling. Results The algorithm was successfully able to identify stimulation intervals, individually for the subject’s left and right quadriceps and hamstring muscles. Smooth cycling was achieved without further adaptation, for both input signals (i.e. crank-angle and normalized thigh-angle). Conclusion The automatic determination of stimulation patterns, on basis of the positive net-torque generated during electrical stimulation, can help to reduce the duration of the initial fitting phase and to improve the quality of pedalling during a FES-Cycling session. In contrast to previous works, the presented algorithm does not rely on a constant angular velocity and thus can be effectively implemented into mobile FES-Cycling systems. As each muscle or muscle group is assessed individually, our algorithm can be used to evaluate the efficiency of novel electrode configurations and thus could promote increased performances during FES-Cycling. Supplementary Information The online version contains supplementary material available at 10.1186/s12984-022-01018-2.
Collapse
|
3
|
van der Scheer JW, Goosey-Tolfrey VL, Valentino SE, Davis GM, Ho CH. Functional electrical stimulation cycling exercise after spinal cord injury: a systematic review of health and fitness-related outcomes. J Neuroeng Rehabil 2021; 18:99. [PMID: 34118958 PMCID: PMC8196442 DOI: 10.1186/s12984-021-00882-8] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 05/19/2021] [Indexed: 01/08/2023] Open
Abstract
OBJECTIVES The objective of this review was to summarize and appraise evidence on functional electrical stimulation (FES) cycling exercise after spinal cord injury (SCI), in order to inform the development of evidence-based clinical practice guidelines. METHODS PubMed, the Cochrane Central Register of Controlled Trials, EMBASE, SPORTDiscus, and CINAHL were searched up to April 2021 to identify FES cycling exercise intervention studies including adults with SCI. In order to capture the widest array of evidence available, any outcome measure employed in such studies was considered eligible. Two independent reviewers conducted study eligibility screening, data extraction, and quality appraisal using Cochranes' Risk of Bias or Downs and Black tools. Each study was designated as a Level 1, 2, 3 or 4 study, dependent on study design and quality appraisal scores. The certainty of the evidence for each outcome was assessed using GRADE ratings ('High', 'Moderate', 'Low', or 'Very low'). RESULTS Ninety-two studies met the eligibility criteria, comprising 999 adults with SCI representing all age, sex, time since injury, lesion level and lesion completeness strata. For muscle health (e.g., muscle mass, fiber type composition), significant improvements were found in 3 out of 4 Level 1-2 studies, and 27 out of 32 Level 3-4 studies (GRADE rating: 'High'). Although lacking Level 1-2 studies, significant improvements were also found in nearly all of 35 Level 3-4 studies on power output and aerobic fitness (e.g., peak power and oxygen uptake during an FES cycling test) (GRADE ratings: 'Low'). CONCLUSION Current evidence indicates that FES cycling exercise improves lower-body muscle health of adults with SCI, and may increase power output and aerobic fitness. The evidence summarized and appraised in this review can inform the development of the first international, evidence-based clinical practice guidelines for the use of FES cycling exercise in clinical and community settings of adults with SCI. Registration review protocol: CRD42018108940 (PROSPERO).
Collapse
Affiliation(s)
- Jan W van der Scheer
- Peter Harrison Centre for Disability Sport, School for Sport, Exercise and Health Sciences, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK
- The Healthcare Improvement Studies (THIS) Institute, Department of Public Health and Primary Care, School of Clinical Medicine, University of Cambridge, Cambridge Biomedical Campus, Clifford Allbutt Building, Cambridge, CB2 OAH, UK
| | - Victoria L Goosey-Tolfrey
- Peter Harrison Centre for Disability Sport, School for Sport, Exercise and Health Sciences, Loughborough University, Epinal Way, Loughborough, LE11 3TU, UK
| | - Sydney E Valentino
- Department of Kinesiology, McMaster University, Room IWC EG115, 1280 Main St. W., Hamilton, ON, L8S 4K1, Canada
| | - Glen M Davis
- Discipline of Exercise and Sport Sciences, Faculty of Medicine and Health, Sydney School of Health Sciences, University of Sydney, Sydney, NSW, 2006, Australia
| | - Chester H Ho
- Division of Physical Medicine & Rehabilitation, Faculty of Medicine & Dentistry, University of Alberta, Edmonton, AB, T6G 2R3, Canada.
| |
Collapse
|
4
|
Giannasi LC, Dutra MTS, Tenguan VLS, Mancilha GP, Silva GRC, Fillietaz-Bacigalupo E, da Silva DB, Politti F, Nacif SR, de Oliveira EF, da Rocha JC, Rocha CT, Romero MM, de Oliveira CS, de Oliveira LVF, de Mello Rode S, Koga-Ito CY, Amorim JBO, Salgado MAC, Gomes MF. Evaluation of the masticatory muscle function, physiological sleep variables, and salivary parameters after electromechanical therapeutic approaches in adult patients with Down syndrome: a randomized controlled clinical trial. Trials 2019; 20:215. [PMID: 30975204 PMCID: PMC6460660 DOI: 10.1186/s13063-019-3300-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2018] [Accepted: 03/18/2019] [Indexed: 01/12/2023] Open
Abstract
Background There are many comorbidities associated with Down syndrome (DS), including obstructive sleep apnea (OSA) and masticatory muscle alteration. Muscular hypotonia, in particular, of the masticatory and oropharyngeal muscles is one of the main characteristics of individuals with DS, resulting in impairments of speech, swallowing, and mastication in these individuals. In addition, total or partial obstruction of the airways during sleep can occur due to pharyngeal hypotonia, leading to snoring and to OSA. This progressive respiratory disorder is associated with a high risk of morbidity and mortality in individuals with DS. The aim of this research is to assess the therapeutic effects of surface neuromuscular electrical stimulation (NMES), the mastication apparatus (MA), and a mandibular advancement oral appliance (OAm) with an embedded thermosensitive microchip on the functions of masticatory muscles (bilateral masseter and temporal muscles), physiological sleep variables, and salivary parameters in adult patients with DS. Methods The patients with DS will be randomly selected and divided into three groups (DS-NMES, DS-MA, and DS-OAm) with a minimum of 10 patients in each group. A thermosensitive microchip will be embedded in the OAm to record its compliance. The therapeutic effects on masticatory muscle function will be investigated through electromyography, a caliper, and a force-transducer device; the sleep variables, in turn, will be evaluated by means of polysomnography. The physicochemical and microbiological properties of the saliva will also be analyzed, including the salivary flow, viscosity, buffer capacity, cortisol levels (susceptibility to psychological and/or physical stress), and Pseudomonas aeruginosa levels (risk of aspiration pneumonia) in these patients. The methods determined for this study will be carried out prior to and after 2 months of the recommended therapies. Discussion The primary outcomes would be the improvement and/or reestablishment of the function of masticatory muscles and the physiological sleep variables in this target public since individuals with DS commonly present generalized muscular hypotonia and dysfunction of the oropharyngeal musculature. As a secondary outcome indicator, the impact of the applied therapies (NMES, MA, and OAm) on the salivary microbiological and physicochemical properties in DS individuals will also be assessed. Furthermore, the compliance of OAm usage will be measured through a thermosensitive microchip. Trial registration Registro Brasileiro de Ensaios Clínicos, RBR-3qp5np. Registered on 20 February 2018. Electronic supplementary material The online version of this article (10.1186/s13063-019-3300-0) contains supplementary material, which is available to authorized users.
Collapse
Affiliation(s)
- Lilian Chrystiane Giannasi
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil. .,Metropolitan University of Santos, Santos, Brazil. .,University Center of Anápolis-UniEvangélica, Anápolis, Brazil.
| | - Marignês T S Dutra
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Vera L S Tenguan
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Gabriela P Mancilha
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Gabriela R C Silva
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Elaine Fillietaz-Bacigalupo
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Daniel B da Silva
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | | | - Sergio R Nacif
- Hospital do Servidor Público Estadual de São Paulo (IAMSPE-HSPE), São Paulo, Brazil
| | | | - João C da Rocha
- Discipline of Pediatric Dentistry Institute of Science and Technology, São Paulo, Brazil
| | - Carolina T Rocha
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Mateus M Romero
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | | | | | - Sigmar de Mello Rode
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Cristiane Yumi Koga-Ito
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Jose B O Amorim
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Miguel A C Salgado
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| | - Mônica F Gomes
- Center of Biosciences Applied to Patients with Special Health Care Needs (CEBAPE), Institute of Science and Technology, São José dos Campos Campus, São Paulo State University-UNESP, R: Esperança 265, São Paulo, SP, Brazil
| |
Collapse
|