1
|
Lubner MG, Ziemlewicz TJ, Wells SA, Li K, Wu PH, Hinshaw JL, Lee FT, Brace CL. Advanced CT techniques for hepatic microwave ablation zone monitoring and follow-up. Abdom Radiol (NY) 2022; 47:2658-2668. [PMID: 34731282 DOI: 10.1007/s00261-021-03333-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 10/21/2021] [Accepted: 10/22/2021] [Indexed: 01/18/2023]
Abstract
PURPOSE To evaluate utility of advanced CT techniques including HighlY constrained back-projection and dual-energy CT for intra- and post-procedure hepatic microwave ablation zone monitoring. METHODS 8 hepatic microwave ablations were performed in 4 adult swine (5 min/65 W). Low-dose routine CECT and dual-energy CT images were obtained every 1 min during ablation. Images were reconstructed ± HYPR. Image quality and dose metrics were collected. 21 MWA were performed in 4 adult swine. Immediate post-procedure CECT was performed in the arterial, portal venous, and delayed phases using both routine and DECT imaging with full-dose weight-based IV contrast dosing. An additional 16 MWA were subsequently performed in 2 adult swine. Immediate post-procedure CT was performed with half-dose IV contrast using routine and DECT. 12 patients (10 M/2F, mean age 62.4 yrs) with 14 hepatic tumors (4 HCC, 10 metastatic lesions) treated with MWA were prospectively imaged with DECT 1 month post-procedure. 120 kV equivalent images were compared to DECT [51 keV, iodine material density]. Image quality and dose metrics were collected. RESULTS Gas created during MWA led to high CNR in all intraprocedural CT datasets. Optimal CNRs were noted at 4 min with CNR 6.7, 15.5,15.9, and 21.5 on LD-CECT, LD-CECT + HYPR, DECT, and DECT + HYPR, respectively (p < 0.001). Image quality scores at 4 min were 1.8, 2.8, 2.4, and 3, respectively (p < 0.001). Mean radiation dose (CTDIvol) was eightfold higher for the DECT series. For swine, post-procedural DECT images (IMD/51 keV) showed improved CNR compared to routine CT at all time points with full and with reduced dose contrast (CNR 4.6, 3.2, and 1.5, respectively, at half-contrast dose, p < 0.001). For human subjects, the 51 keV and IMD images showed higher CNRs (5.8, 4.8 vs 4.0, p < 0.001) and SNRs (3.7, 5.9 vs 2.8). Ablation zone sharpness was improved with DECT (routine 3.0 ± 0.7, DECT 3.5 ± 0.5). Diagnostic confidence was higher with DECT (routine 2.3 ± 0.9, DECT 2.6 ± 0.8). Mean DLP for DECT was 905.7 ± 606 mGy-cm, CTDIvol 37.5 ± 21.2 mGy, and effective dose 13.6 ± 9.1 mSv, slightly higher than conventional CT series. CONCLUSION Advanced CT techniques can improve CT image quality in peri-procedural hepatic microwave ablation zone evaluation.
Collapse
Affiliation(s)
- Meghan G Lubner
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA.
| | - Timothy J Ziemlewicz
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Shane A Wells
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Ke Li
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Po-Hung Wu
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Biomedical and Electrical Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
- Department of Electrical and Computer Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - J Louis Hinshaw
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Fred T Lee
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
| | - Chris L Brace
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, E3/311 Clinical Sciences Center, 600 Highland Ave, Madison, WI, 53792, USA
- Department of Medical Physics, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
- Department of Biomedical and Electrical Engineering, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| |
Collapse
|
2
|
Wu PH, Borden Z, Brace CL. Ablation zone visualization enhancement by periodic contrast-enhancement computed tomography during microwave ablation. Med Phys 2017; 44:2132-2140. [PMID: 28391605 DOI: 10.1002/mp.12266] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 04/04/2017] [Accepted: 04/04/2017] [Indexed: 01/05/2023] Open
Abstract
PURPOSE Intra-procedural contrast-enhanced computed tomography (CECT) has been proposed to monitor the growth of thermal ablations. The primary challenge with multiple CT acquisitions is reducing radiation dose while maintaining sufficient image quality. The purpose of this study was to evaluate the feasibility of applying local highly constrained backprojection reconstruction (HYPR-LR) on periodic CECT images acquired with low-dose protocols, and to determine whether the ablations visible on CT were commensurate to gross pathology. METHODS Low-dose (CTDIvol≤1.49mGy), temporal CECT volumes were acquired during microwave ablation on normal porcine liver. HYPR processing was performed on each volume after image registration. Ablation signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were collected to evaluate the degree of enhancement of image quality and ablation zone visualization. Ablation zones were manually segmented on HYPR and non-HYPR images and compared spatially using Dice's coefficient. The dimensions of ablation zones were also compared to gross pathology by correlation and dimensional differences. RESULTS The SNR and CNR of ablation zones were increased after HYPR processing. The manually segmented ablation zone was highly similar to gross pathology with a Dice coefficient of 0.81 ± 0.03, while the low-dose CECT had a smaller Dice coefficient of 0.72 ± 0.05. Both HYPR and low-dose CECT had high correlation to gross pathology (0.99 and 0.94, respectively), but the variance of measurements were lower after HYPR processing compared to unprocessed images. The relative difference in area, length of long axis, and length of short axis for HYPR image were 13.1 ± 5.6%, 9.7 ± 4.2%, and 15.2 ± 2.8%, which were lower than those for low-dose CECT at 37.5 ± 6.0%, 17.7 ± 2.8%, and 28.9 ± 5.4%. CONCLUSION HYPR processing applied to periodic CECT images can enhance ablation zone visualization. HYPR processing may potentially enable CECT in real-time ablation monitoring under strict regulation of radiation dose.
Collapse
Affiliation(s)
- Po-Hung Wu
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Zachary Borden
- Department of Radiology, University of Wisconsin-Madison, Madison, WI, 53705, USA
| | - Christopher L Brace
- Department of Biomedical Engineering and Radiology, University of Wisconsin-Madison, Madison, WI, 53705, USA
| |
Collapse
|
3
|
Cornelis FH, Durack JC, Kimm SY, Wimmer T, Coleman JA, Solomon SB, Srimathveeravalli G. A Comparative Study of Ablation Boundary Sharpness After Percutaneous Radiofrequency, Cryo-, Microwave, and Irreversible Electroporation Ablation in Normal Swine Liver and Kidneys. Cardiovasc Intervent Radiol 2017; 40:1600-1608. [PMID: 28516273 DOI: 10.1007/s00270-017-1692-3] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/21/2017] [Accepted: 05/03/2017] [Indexed: 02/08/2023]
Abstract
PURPOSE To compare ablation boundary sharpness after percutaneous radiofrequency ablation (RFA), cryoablation (CA), microwave ablation (MWA) and irreversible electroporation (IRE) ablation in normal swine liver and kidney. MATERIALS AND METHODS Percutaneous CT-guided RFA (n = 5), CA (n = 5), MWA (n = 5) and IRE (n = 5) were performed in the liver and kidney of four Yorkshire pigs. Parameters were chosen to produce ablations 2-3 cm in diameter with a single ablation probe. Contrast-enhanced CT imaging was performed 24 h after ablation, and animals were killed. Treated organs were removed and processed for histologic analysis with hematoxylin and eosin, and terminal deoxynucleotidyl transferase dUTP nick end labeling (TUNEL). Three readers independently analyzed CT, H&E and TUNEL stained images of the ablation boundary to delineate regions of (1) viable cells, (2) complete necrosis or (3) mixture of viable and necrotic cells which was defined as the transition zone (TZ). The width of TZ was compared across the techniques and organs. RESULTS Ablations appeared as non-contrast-enhancing regions on CT with sharp transition to enhancing normal tissue. On TUNEL stained slides, the mean width (μm) of the TZ after MWA was 319 ± 157 in liver and 267 ± 95 in kidney, which was significantly lower than RFA (811 ± 477 and 938 ± 429); CA (452 ± 222 and 700 ± 563); and IRE (1319 ± 682 and 1570 ± 962) (all p < 0.01). No significant differences were observed between the organs. CONCLUSION Under similar conditions, the width of the TZ at the ablation boundary varies significantly between different ablation techniques.
Collapse
Affiliation(s)
- Francois H Cornelis
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Jeremy C Durack
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Simon Y Kimm
- Department of Urology, Palo Alto Medical Foundation, Palo Alto, CA, USA
| | | | - Jonathan A Coleman
- Division of Urology, Department of Surgery, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Stephen B Solomon
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA
| | - Govindarajan Srimathveeravalli
- Department of Radiology, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, NY, 10065, USA. .,Weill Cornell Medical College, New York, NY, USA.
| |
Collapse
|
4
|
Wu PH, Brace CL. Analysis of iodinated contrast delivered during thermal ablation: is material trapped in the ablation zone? Phys Med Biol 2016; 61:6041-54. [PMID: 27452478 DOI: 10.1088/0031-9155/61/16/6041] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
Abstract
Intra-procedural contrast-enhanced CT (CECT) has been proposed to evaluate treatment efficacy of thermal ablation. We hypothesized that contrast material delivered concurrently with thermal ablation may become trapped in the ablation zone, and set out to determine whether such an effect would impact ablation visualization. CECT images were acquired during microwave ablation in normal porcine liver with: (A) normal blood perfusion and no iodinated contrast, (B) normal perfusion and iodinated contrast infusion or (C) no blood perfusion and residual iodinated contrast. Changes in CT attenuation were analyzed from before, during and after ablation to evaluate whether contrast was trapped inside of the ablation zone. Visualization was compared between groups using post-ablation contrast-to-noise ratio (CNR). Attenuation gradients were calculated at the ablation boundary and background to quantitate ablation conspicuity. In Group A, attenuation decreased during ablation due to thermal expansion of tissue water and water vaporization. The ablation zone was difficult to visualize (CNR = 1.57 ± 0.73, boundary gradient = 0.7 ± 0.4 HU mm(-1)), leading to ablation diameter underestimation compared to gross pathology. Group B ablations saw attenuation increase, suggesting that iodine was trapped inside the ablation zone. However, because the normally perfused liver increased even more, Group B ablations were more visible than Group A (CNR = 2.04 ± 0.84, boundary gradient = 6.3 ± 1.1 HU mm(-1)) and allowed accurate estimation of the ablation zone dimensions compared to gross pathology. Substantial water vaporization led to substantial attenuation changes in Group C, though the ablation zone boundary was not highly visible (boundary gradient = 3.9 ± 1.1 HU mm(-1)). Our results demonstrate that despite iodinated contrast being trapped in the ablation zone, ablation visibility was highest when contrast is delivered intra-procedurally. Therefore, CECT may be feasible for real-time thermal ablation monitoring.
Collapse
Affiliation(s)
- Po-Hung Wu
- Department of Electrical and Computer Engineering, University of Wisconsin-Madison, 1415 Engineering Dr, Madison, WI 53706, USA
| | | |
Collapse
|
5
|
Fite BZ, Wong A, Liu Y, Mahakian LM, Tam SM, Aina O, Hubbard NE, Borowsky A, Cardiff RD, Dumont E, Ferrara KW. Magnetic resonance imaging assessment of effective ablated volume following high intensity focused ultrasound. PLoS One 2015; 10:e0120037. [PMID: 25785992 PMCID: PMC4365027 DOI: 10.1371/journal.pone.0120037] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2014] [Accepted: 01/15/2015] [Indexed: 01/30/2023] Open
Abstract
Under magnetic resonance (MR) guidance, high intensity focused ultrasound (HIFU) is capable of precise and accurate delivery of thermal dose to tissues. Given the excellent soft tissue imaging capabilities of MRI, but the lack of data on the correlation of MRI findings to histology following HIFU, we sought to examine tumor response to HIFU ablation to determine whether there was a correlation between histological findings and common MR imaging protocols in the assessment of the extent of thermal damage. Female FVB mice (n = 34), bearing bilateral neu deletion tumors, were unilaterally insonated under MR guidance, with the contralateral tumor as a control. Between one and five spots (focal size 0.5 × 0.5 × 2.5 mm3) were insonated per tumor with each spot receiving approximately 74.2 J of acoustic energy over a period of 7 seconds. Animals were then imaged on a 7T MR scanner with several protocols. T1 weighted images (with and without gadolinium contrast) were collected in addition to a series of T2 weighted and diffusion weighted images (for later reconstruction into T2 and apparent diffusion coefficient maps), immediately following ablation and at 6, 24, and 48 hours post treatment. Animals were sacrificed at each time point and both insonated/treated and contralateral tumors removed and stained for NADH-diaphorase, caspase 3, or with hematoxylin and eosin (H&E). We found the area of non-enhancement on contrast enhanced T1 weighted imaging immediately post ablation correlated with the region of tissue receiving a thermal dose CEM43 ≥ 240 min. Moreover, while both tumor T2 and apparent diffusion coefficient values changed from pre-ablation values, contrast enhanced T1 weighted images appeared to be more senstive to changes in tissue viability following HIFU ablation.
Collapse
Affiliation(s)
- Brett Z. Fite
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
| | - Andrew Wong
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
| | - Yu Liu
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
| | - Lisa M. Mahakian
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
| | - Sarah M. Tam
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
| | - Olulanu Aina
- Center for Comparative Medicine, University of California Davis, Davis, CA, 95616, United States of America
| | - Neil E. Hubbard
- Center for Comparative Medicine, University of California Davis, Davis, CA, 95616, United States of America
| | - Alexander Borowsky
- Center for Comparative Medicine, University of California Davis, Davis, CA, 95616, United States of America
- Department of Pathology and Laboratory Medicine, School of Medicine, University of California Davis, Davis, CA, 95616, United States of America
| | - Robert D. Cardiff
- Center for Comparative Medicine, University of California Davis, Davis, CA, 95616, United States of America
- Department of Pathology and Laboratory Medicine, School of Medicine, University of California Davis, Davis, CA, 95616, United States of America
| | | | - Katherine W. Ferrara
- Department of Biomedical Engineering, University of California Davis, Davis, CA, 95616, United States of America
- * E-mail:
| |
Collapse
|