1
|
Lim J, Wang PT, Bashford L, Kellis S, Shaw SJ, Gong H, Armacost M, Heydari P, Do AH, Andersen RA, Liu CY, Nenadic Z. Suppression of cortical electrostimulation artifacts using pre-whitening and null projection. J Neural Eng 2023; 20:056018. [PMID: 37666246 DOI: 10.1088/1741-2552/acf68b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Accepted: 09/04/2023] [Indexed: 09/06/2023]
Abstract
Objective.Invasive brain-computer interfaces (BCIs) have shown promise in restoring motor function to those paralyzed by neurological injuries. These systems also have the ability to restore sensation via cortical electrostimulation. Cortical stimulation produces strong artifacts that can obscure neural signals or saturate recording amplifiers. While front-end hardware techniques can alleviate this problem, residual artifacts generally persist and must be suppressed by back-end methods.Approach.We have developed a technique based on pre-whitening and null projection (PWNP) and tested its ability to suppress stimulation artifacts in electroencephalogram (EEG), electrocorticogram (ECoG) and microelectrode array (MEA) signals from five human subjects.Main results.In EEG signals contaminated by narrow-band stimulation artifacts, the PWNP method achieved average artifact suppression between 32 and 34 dB, as measured by an increase in signal-to-interference ratio. In ECoG and MEA signals contaminated by broadband stimulation artifacts, our method suppressed artifacts by 78%-80% and 85%, respectively, as measured by a reduction in interference index. When compared to independent component analysis, which is considered the state-of-the-art technique for artifact suppression, our method achieved superior results, while being significantly easier to implement.Significance.PWNP can potentially act as an efficient method of artifact suppression to enable simultaneous stimulation and recording in bi-directional BCIs to biomimetically restore motor function.
Collapse
Affiliation(s)
- Jeffrey Lim
- Department of Biomedical Engineering, University of California Irvine (UCI), Irvine, CA 92697, United States of America
| | - Po T Wang
- Department of Biomedical Engineering, University of California Irvine (UCI), Irvine, CA 92697, United States of America
| | - Luke Bashford
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, United States of America
| | - Spencer Kellis
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, United States of America
- Department of Neurological Surgery, Keck School of Medicine of University of Southern California (USC), Los Angeles, CA 90033, United States of America
- USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA 90033, United States of America
| | - Susan J Shaw
- Department of Neurology, Rancho Los Amigos National Rehabilitation Center, Downey, CA 90242, United States of America
- Department of Neurology, Keck School of Medicine of USC, Los Angeles, CA 90033, United States of America
| | - Hui Gong
- Department of Neurology, Rancho Los Amigos National Rehabilitation Center, Downey, CA 90242, United States of America
- Department of Neurology, Keck School of Medicine of USC, Los Angeles, CA 90033, United States of America
| | - Michelle Armacost
- Department of Neurology, Rancho Los Amigos National Rehabilitation Center, Downey, CA 90242, United States of America
- Department of Neurology, Keck School of Medicine of USC, Los Angeles, CA 90033, United States of America
| | - Payam Heydari
- Department of Biomedical Engineering, University of California Irvine (UCI), Irvine, CA 92697, United States of America
- Department of Electrical Engineering and Computer Science, UCI, Irvine, CA 92697, United States of America
| | - An H Do
- Department of Neurology, UCI, Irvine, CA 92697, United States of America
| | - Richard A Andersen
- Division of Biology and Biological Engineering, California Institute of Technology, Pasadena, CA 91125, United States of America
| | - Charles Y Liu
- Department of Neurological Surgery, Keck School of Medicine of University of Southern California (USC), Los Angeles, CA 90033, United States of America
- USC Neurorestoration Center, Keck School of Medicine of USC, Los Angeles, CA 90033, United States of America
- Department of Neurosurgery, Rancho Los Amigos National Rehabilitation Center, Downey, CA 90242, United States of America
| | - Zoran Nenadic
- Department of Biomedical Engineering, University of California Irvine (UCI), Irvine, CA 92697, United States of America
- Department of Electrical Engineering and Computer Science, UCI, Irvine, CA 92697, United States of America
| |
Collapse
|
2
|
Weerasinghe G, Duchet B, Bick C, Bogacz R. Optimal closed-loop deep brain stimulation using multiple independently controlled contacts. PLoS Comput Biol 2021; 17:e1009281. [PMID: 34358224 PMCID: PMC8405008 DOI: 10.1371/journal.pcbi.1009281] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 08/30/2021] [Accepted: 07/15/2021] [Indexed: 11/18/2022] Open
Abstract
Deep brain stimulation (DBS) is a well-established treatment option for a variety of neurological disorders, including Parkinson’s disease and essential tremor. The symptoms of these disorders are known to be associated with pathological synchronous neural activity in the basal ganglia and thalamus. It is hypothesised that DBS acts to desynchronise this activity, leading to an overall reduction in symptoms. Electrodes with multiple independently controllable contacts are a recent development in DBS technology which have the potential to target one or more pathological regions with greater precision, reducing side effects and potentially increasing both the efficacy and efficiency of the treatment. The increased complexity of these systems, however, motivates the need to understand the effects of DBS when applied to multiple regions or neural populations within the brain. On the basis of a theoretical model, our paper addresses the question of how to best apply DBS to multiple neural populations to maximally desynchronise brain activity. Central to this are analytical expressions, which we derive, that predict how the symptom severity should change when stimulation is applied. Using these expressions, we construct a closed-loop DBS strategy describing how stimulation should be delivered to individual contacts using the phases and amplitudes of feedback signals. We simulate our method and compare it against two others found in the literature: coordinated reset and phase-locked stimulation. We also investigate the conditions for which our strategy is expected to yield the most benefit. In this paper we use computer models of brain tissue to derive an optimal control algorithm for a recently developed new generation of deep brain stimulation (DBS) devices. DBS is a treatment for a variety of neurological disorders including Parkinson’s disease, essential tremor, depression and pain. There is a growing amount of evidence to suggest that delivering stimulation according to feedback from patients, or closed-loop, has the potential to improve the efficacy, efficiency and side effects of the treatment. An important recent development in DBS technology are electrodes with multiple independently controllable contacts and this paper is a theoretical study into the effects of using this new technology. On the basis of a theoretical model, we devise a closed-loop strategy and address the question of how to best apply DBS across multiple contacts to maximally desynchronise neural populations. We demonstrate using numerical simulation that, for the systems we consider, our methods are more effective than two well-known alternatives, namely phase-locked stimulation and coordinated reset. We also predict that the benefits of using multiple contacts should depend strongly on the intrinsic neuronal response. The insights from this work should lead to a better understanding of how to implement and optimise closed-loop multi-contact DBS systems which in turn should lead to more effective and efficient DBS treatments.
Collapse
Affiliation(s)
- Gihan Weerasinghe
- MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
- * E-mail:
| | - Benoit Duchet
- MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| | - Christian Bick
- Department of Mathematics, Vrije Universiteit Amsterdam, Amsterdam, The Netherlands
- Systems and Network Neuroscience, Amsterdam Neuroscience, Amsterdam, The Netherlands
- Mathematical Institute, University of Oxford, Oxford, United Kingdom
- Department of Mathematics, University of Exeter, Exeter, United Kingdom
| | - Rafal Bogacz
- MRC Brain Network Dynamics Unit, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, United Kingdom
| |
Collapse
|