1
|
Smith TJ, Wu Y, Cheon C, Khan AA, Srinivasan H, Capadona JR, Cogan SF, Pancrazio JJ, Engineer CT, Hernandez-Reynoso AG. Behavioral paradigm for the evaluation of stimulation-evoked somatosensory perception thresholds in rats. Front Neurosci 2023; 17:1202258. [PMID: 37383105 PMCID: PMC10293669 DOI: 10.3389/fnins.2023.1202258] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2023] [Accepted: 05/22/2023] [Indexed: 06/30/2023] Open
Abstract
Intracortical microstimulation (ICMS) of the somatosensory cortex via penetrating microelectrode arrays (MEAs) can evoke cutaneous and proprioceptive sensations for restoration of perception in individuals with spinal cord injuries. However, ICMS current amplitudes needed to evoke these sensory percepts tend to change over time following implantation. Animal models have been used to investigate the mechanisms by which these changes occur and aid in the development of new engineering strategies to mitigate such changes. Non-human primates are commonly the animal of choice for investigating ICMS, but ethical concerns exist regarding their use. Rodents are a preferred animal model due to their availability, affordability, and ease of handling, but there are limited choices of behavioral tasks for investigating ICMS. In this study, we investigated the application of an innovative behavioral go/no-go paradigm capable of estimating ICMS-evoked sensory perception thresholds in freely moving rats. We divided animals into two groups, one receiving ICMS and a control group receiving auditory tones. Then, we trained the animals to nose-poke - a well-established behavioral task for rats - following either a suprathreshold ICMS current-controlled pulse train or frequency-controlled auditory tone. Animals received a sugar pellet reward when nose-poking correctly. When nose-poking incorrectly, animals received a mild air puff. After animals became proficient in this task, as defined by accuracy, precision, and other performance metrics, they continued to the next phase for perception threshold detection, where we varied the ICMS amplitude using a modified staircase method. Finally, we used non-linear regression to estimate perception thresholds. Results indicated that our behavioral protocol could estimate ICMS perception thresholds based on ~95% accuracy of rat nose-poke responses to the conditioned stimulus. This behavioral paradigm provides a robust methodology for evaluating stimulation-evoked somatosensory percepts in rats comparable to the evaluation of auditory percepts. In future studies, this validated methodology can be used to study the performance of novel MEA device technologies on ICMS-evoked perception threshold stability using freely moving rats or to investigate information processing principles in neural circuits related to sensory perception discrimination.
Collapse
Affiliation(s)
- Thomas J. Smith
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Yupeng Wu
- Department of Materials Science and Engineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Claire Cheon
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Arlin A. Khan
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Hari Srinivasan
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
| | - Jeffrey R. Capadona
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland, OH, United States
- Advanced Platform Technology Center, Louis Stokes Cleveland Veterans Affairs Medical Center, Cleveland, OH, United States
| | - Stuart F. Cogan
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Joseph J. Pancrazio
- Department of Bioengineering, The University of Texas at Dallas, Richardson, TX, United States
| | - Crystal T. Engineer
- School of Behavioral and Brain Sciences, The University of Texas at Dallas, Richardson, TX, United States
- Texas Biomedical Device Center, The University of Texas at Dallas, Richardson, TX, United States
| | | |
Collapse
|
2
|
Urdaneta ME, Kunigk NG, Delgado F, Otto KJ. Somatosensory Cortex Microstimulation: Behavioral Effects of Phase Duration and Asymmetric Waveforms. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1809-1812. [PMID: 31946248 DOI: 10.1109/embc.2019.8856579] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Intracortical microstimulation has proven to be effective in a variety of sensory applications, such as returning touch percepts to paralyzed patients. The parameters of microstimulation play an important role in the perception quality of the stimulus. Eliciting naturalistic percepts is essential for the adaptability and functionality of this technology. Compared to the typical biphasic symmetric waveforms, asymmetric waveforms enhance activation selectivity by preferentially activating cell bodies. Behavioral studies have shown that asymmetric waveforms can elicit behavioral responses, but these require higher charges than typical symmetric waveforms. Here, we investigated the effects of phase duration and waveform asymmetry for somatosensory cortex intracortical microstimulation of freely-behaving rats. Detection thresholds were obtained using a conditioned avoidance behavioral paradigm. Our results indicate that phase duration has significant effects on threshold regardless of symmetry, polarity, and phase order of the waveform. Specifically, shorter phase durations tend to elicit lower behavioral thresholds. Analogous to studies in the auditory cortex, asymmetric waveforms in which the short pulse was cathodic were more effective than those with short-anodic pulses. With short phase durations, these short-cathodic waveforms are capable of evoking behavioral responses at low charges (<; 5 nC/Phase). Altogether, these results suggest the possibility of cell body selective microstimulation at safe thresholds, as well as the potential translatability of neuromodulation parameters across distinct sensory cortical areas.
Collapse
|
3
|
Rajan AT, Boback JL, Dammann JF, Tenore FV, Wester BA, Otto KJ, Gaunt RA, Bensmaia SJ. The effects of chronic intracortical microstimulation on neural tissue and fine motor behavior. J Neural Eng 2015; 12:066018. [PMID: 26479701 PMCID: PMC8129590 DOI: 10.1088/1741-2560/12/6/066018] [Citation(s) in RCA: 50] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
Objective. One approach to conveying sensory feedback in neuroprostheses is to electrically stimulate sensory neurons in the cortex. For this approach to be viable, it is critical that intracortical microstimulation (ICMS) causes minimal damage to the brain. Here, we investigate the effects of chronic ICMS on the neuronal tissue across a variety of stimulation regimes in non-human primates. We also examine each animal’s ability to use their hand—the cortical representation of which is targeted by the ICMS—as a further assay of possible neuronal damage. Approach. We implanted electrode arrays in the primary somatosensory cortex of three Rhesus macaques and delivered ICMS four hours per day, five days per week, for six months. Multiple regimes of ICMS were delivered to investigate the effects of stimulation parameters on the tissue and behavior. Parameters included current amplitude (10–100 μA), pulse train duration (1, 5 s), and duty cycle (1/1, 1/3). We then performed a range of histopathological assays on tissue near the tips of both stimulated and unstimulated electrodes to assess the effects of chronic ICMS on the tissue and their dependence on stimulation parameters. Main results. While the implantation and residence of the arrays in the cortical tissue did cause significant damage, chronic ICMS had no detectable additional effect; furthermore, the animals exhibited no impairments in fine motor control. Significance. Chronic ICMS may be a viable means to convey sensory feedback in neuroprostheses as it does not cause significant damage to the stimulated tissue.
Collapse
Affiliation(s)
- Alexander T Rajan
- Committee on Computational Neuroscience, University of Chicago, Chicago, IL, USA. Department of Organismal Biology and Anatomy, University of Chicago, Chicago, IL, USA
| | | | | | | | | | | | | | | |
Collapse
|
4
|
Lycke RJ, Schendel A, Williams JC, Otto KJ. In vivo evaluation of a μECoG array for chronic stimulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2014; 2014:1294-7. [PMID: 25570203 DOI: 10.1109/embc.2014.6943835] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Advancements in neural interfaces capable of neural stimulation have shown that neural implants may potentially target the central nervous system to treat neurological disorders. Unfortunately, many of the current technologies used to stimulate and record from the brain do not suffice for this purpose; those that provide a sufficient channel density, which is required for interfacing and chronic functionality in vivo, fail quickly, while others that last for an extended period of time in vivo are limited in recording and stimulation capabilities. Of the current methodologies available, electrocorticography (ECoG) based implants show promise for providing both high channel density interfaces as well as chronic functionality after implantation. This study evaluates the performance of a μECoG for the purpose of chronic stimulation.
Collapse
|
5
|
Regele OB, Koivuniemi AS, Otto KJ. Constant RMS versus constant peak modulation for the perceptual equivalence of sinusoidal amplitude modulated signals. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2013; 2013:3115-3118. [PMID: 24110387 PMCID: PMC4082400 DOI: 10.1109/embc.2013.6610200] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
Neuroprosthetics using intracortical microstimulation can potentially alleviate sensory deprivation due to injury or disease. However the information bandwidth of a single microstimulation channel remains largely unanswered. This paper presents three experiments that examine the importance of Peak Power/Charge and RMS Power/Charge for detection of acoustic and electrical Sinusoidal Amplitude Modulated stimuli by the auditory system. While the peripheral auditory system is sensitive to RMS power cues for the detection of acoustic stimuli, here we provide results that suggest that the auditory cortex is sensitive to peak charge cues for electrical stimuli. Varying the modulation frequency and depth do not change this effect for detection of modulated electrical stimuli.
Collapse
Affiliation(s)
- Oliver B. Regele
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907 USA
| | - Andrew S. Koivuniemi
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907 USA
| | - Kevin J. Otto
- Department of Biological Sciences and the Weldon School of Biomedical Engineering, Purdue University, West Lafayette, IN 47907 USA, phone: 765-496-1012; fax 765-496-1912
| |
Collapse
|