1
|
Lee SY, Cheng PH, Tsou CF, Lin CC, Shieh GS. A 2.4 GHz ISM Band OOK Transceiver With High Energy Efficiency for Biomedical Implantable Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2020; 14:113-124. [PMID: 31902768 DOI: 10.1109/tbcas.2019.2963202] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
This article presents a high energy efficiency, high-integrated, and low-power on-off keying transceiver for a 2.4 GHz industrial scientific medical band. The proposed receiver includes an input matching network, a low-noise amplifier, a novel single-to-differential envelope detector, a level shifter, cascaded baseband amplifiers, and a hysteresis comparator. The proposed transmitter includes a bias-stimulating circuit, a current-reused self-mixing voltage controlled oscillator, and a quadruple-transconductance power amplifier. Numerous proposed techniques implemented in the mentioned circuits improve the energy per bit and power efficiency. Therefore, the proposed receiver for short-distanced propagation can achieve a sensitivity of -46 dBm with a carrier frequency of 2.45 GHz and a high data rate of 2 Mbps. The proposed transmitter achieves an output power of -17 dBm with a high data rate of 20 Mbps. This work is fabricated in a TSMC 0.18 μm CMOS process and consumes 160 μW and 0.6 mW in the receiver and transmitter, respectively, from a 1.2 V supply voltage. The energy per bit of 80 pJ/bit in the receiver part and the figure of merit of 9 in the transmitter part are better than those of existing state-of-the-art transceivers.
Collapse
|
2
|
Mao J, Yang H, Lian Y, Zhao B. A Five-Tissue-Layer Human Body Communication Circuit Model Tunable to Individual Characteristics. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:303-312. [PMID: 29570058 DOI: 10.1109/tbcas.2018.2798410] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Human body communication (HBC) has several advantages over traditional wireless communications due to the high conductivity of human body. An accurate body channel model plays a vital role in optimizing the performance and power of HBC transceivers. In this paper, we present a body channel model with three distinct features. First, it takes into account all five body tissue layers resulting better accuracy; second, it adapts to different individuals with the proposed layer thickness estimation technique; third, it counts in the variation of backward coupling capacitance versus different postures. These new features significantly improve the model accuracy. Measurement results show that the proposed model achieves a maximum error of 2.21% in path loss for different human subjects.
Collapse
|
3
|
Mao J, Yang H, Zhao B. An Investigation on Ground Electrodes of Capacitive Coupling Human Body Communication. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2017; 11:910-919. [PMID: 28541910 DOI: 10.1109/tbcas.2017.2683532] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Utilizing the body surface as the signal transmission medium, capacitive coupling human body communication (CC-HBC) can achieve a much higher energy efficiency than conventional wireless communications in future wireless body area network (WBAN) applications. Under the CC-HBC scheme, the body surface serves as the forward signal path, whereas the backward path is formed by the capacitive coupling between the ground electrodes (GEs) of transmitter (TX) and receiver (RX). So the type of communication benefits from a low forward loss, while the backward loss depending on the GE coupling strength dominates the total transmission loss. However, none of the previous works have shown a complete research on the effects of GEs. In this paper, all kinds of GE effects on CC-HBC are investigated by both finite element method (FEM) analysis and human body measurement. We set the TX GE and RX GE at different heights, separation distances, and dimensions to study the corresponding influence on the overall signal transmission path loss. In addition, we also investigate the effects of GEs with different shapes and different TX-to-RX relative angles. Based on all the investigations, an analytical model is derived to evaluate the GE related variations of channel loss in CC-HBC.
Collapse
|
4
|
Mirbozorgi SA, Bahrami H, Sawan M, Rusch LA, Gosselin B. A Single-Chip Full-Duplex High Speed Transceiver for Multi-Site Stimulating and Recording Neural Implants. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2016; 10:643-653. [PMID: 26469635 DOI: 10.1109/tbcas.2015.2466592] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
We present a novel, fully-integrated, low-power full-duplex transceiver (FDT) to support high-density and bidirectional neural interfacing applications (high-channel count stimulating and recording) with asymmetric data rates: higher rates are required for recording (uplink signals) than stimulation (downlink signals). The transmitter (TX) and receiver (RX) share a single antenna to reduce implant size and complexity. The TX uses impulse radio ultra-wide band (IR-UWB) based on an edge combining approach, and the RX uses a novel 2.4-GHz on-off keying (OOK) receiver. Proper isolation (>20 dB) between the TX and RX path is implemented 1) by shaping the transmitted pulses to fall within the unregulated UWB spectrum (3.1-7 GHz), and 2) by space-efficient filtering (avoiding a circulator or diplexer) of the downlink OOK spectrum in the RX low-noise amplifier. The UWB 3.1-7 GHz transmitter can use either OOK or binary phase shift keying (BPSK) modulation schemes. The proposed FDT provides dual band 500-Mbps TX uplink data rate and 100 Mbps RX downlink data rate, and it is fully integrated into standard TSMC 0.18- μm CMOS within a total size of 0.8 mm(2). The total measured power consumption is 10.4 mW in full duplex mode (5 mW at 100 Mbps for RX, and 5.4 mW at 500 Mbps or 10.8 pJ/bit for TX). Additionally, a 3-coil inductive link along with on-chip power management circuits allows to powering up the implantable transceiver wirelessly by delivering 25 mW extracted from a 13.56-MHz carrier signal, at a total efficiency of 41.6%.
Collapse
|
5
|
Zgaren M, Moradi A, Sawan M. Ultra low-power transceiver with novel FSK modulation technique and efficient FSK-to-ASK demodulation. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:7115-8. [PMID: 26737932 DOI: 10.1109/embc.2015.7320032] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Energy-efficient and high-data rate are desired in biomedical devices transceivers. A high-performance transmitter (Tx) and an ultra-low-power receiver (Rx) dedicated to medical implants communications operating at Industrial, Scientific and Medical (ISM) frequency band are presented. Tx benefits from a new efficient Frequency-Shift Keying (FSK) modulation technique which provides up to 20 Mb/s of data-rate and consumes only 0.084 nJ/b validated through fabrication. The receiver consists of an FSK-to-ASK conversion based receiver with OOK fully passive wake-up device (WuRx). This WuRx is battery less with energy harvesting technique which plays an important role in making the RF transceiver energy-efficient. The Rx is achieved with a reduced hardware architecture which does not use an accurate local oscillator, high-Q external inductor and I/Q signal path. The Rx shows -78 dBm sensitivity for 8 Mbps data rate while consuming 639 μW. The proposed circuits are implemented in IBM 0.13 μm CMOS technology with 1.2 V supply voltage.
Collapse
|
6
|
Goodarzy F, Skafidas ES, Gambini S. Feasibility of Energy-Autonomous Wireless Microsensors for Biomedical Applications: Powering and Communication. IEEE Rev Biomed Eng 2014; 8:17-29. [PMID: 25137732 DOI: 10.1109/rbme.2014.2346487] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
In this review, biomedical-related wireless miniature devices such as implantable medical devices, neural prostheses, embedded neural systems, and body area network systems are investigated and categorized. The two main subsystems of such designs, the RF subsystem and the energy source subsystem, are studied in detail. Different application classes are considered separately, focusing on their specific data rate and size characteristics. Also, the energy consumption of state-of-the-art communication practices is compared to the energy that can be generated by current energy scavenging devices, highlighting gaps and opportunities. The RF subsystem is classified, and the suitable architecture for each category of applications is highlighted. Finally, a new figure of merit suitable for wireless biomedical applications is introduced to measure the performance of these devices and assist the designer in selecting the proper system for the required application. This figure of merit can effectively fill the gap of a much required method for comparing different techniques in simulation stage before a final design is chosen for implementation.
Collapse
|
7
|
Tan J, Liew WS, Heng CH, Lian Y. A 2.4 GHz ULP reconfigurable asymmetric transceiver for single-chip wireless neural recording IC. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2014; 8:497-509. [PMID: 25073126 DOI: 10.1109/tbcas.2013.2290533] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
This paper presents a 2.4 GHz ultra-low-power (ULP) reconfigurable asymmetric transceiver and demonstrates its application in wireless neural recording. Fabricated in 0.13 μm CMOS technology, the transceiver is optimized for sensor-gateway communications within a star-shaped network, and supports both the sensor and gateway operation modes. Binary phase-shift keying (BPSK) modulation with high data rate (DR) of 1 to 8 Mbps is used in the uplink from sensor to gateway, while on-off keying (OOK) modulation with low DR of 100 kbps is adopted in the downlink. A fully integrated Class-E PA with moderate output power has also been proposed and achieves power efficiency of 53%. To minimize area usage, inductor reuse is adopted between PA and LNA, and eliminates the need of lossy T/R switch in the RF signal path. When used as sensor, the transceiver with frequency locked phase-locked loop (PLL) achieves TX (BPSK) power efficiency of 28% @ 0 dBm output power, and RX (OOK) sensitivity of -80 dBm @ 100 kbps while consuming only 780 μW . When configured as gateway, the transceiver achieves sensitivity levels of -92, -84.5, and -77 dBm for 1, 5, and 8 Mbps BPSK, respectively. The transceiver is integrated with an 8-channel neural recording front-end, and neural signals from a rat are captured to verify the system functionality.
Collapse
|
8
|
Hong Y, Kim SG, Kim BH, Ha SJ, Lee HJ, Yun GH, Yook JG. Noncontact proximity vital sign sensor based on PLL for sensitivity enhancement. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2014; 8:584-593. [PMID: 24235311 DOI: 10.1109/tbcas.2013.2280913] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
In this paper, a noncontact proximity vital sign sensor, using a phase locked loop (PLL) incorporated with voltage controlled oscillator (VCO) built-in planar type circular resonator, is proposed to enhance sensitivity in severe environments. The planar type circular resonator acts as a series feedback element of the VCO as well as a near-field receiving antenna. The frequency deviation of the VCO related to the body proximity effect ranges from 0.07 MHz/mm to 1.8 MHz/mm (6.8 mV/mm to 205 mV/mm in sensitivity) up to a distance of 50 mm, while the amount of VCO drift is about 21 MHz in the condition of 60 (°)C temperature range and discrete component tolerance of ± 5%. Total frequency variation occurs in the capture range of the PLL which is 60 MHz. Thus, its loop control voltage converts the amount of frequency deviation into a difference of direct current (DC) voltage, which is utilized to extract vital signs regardless of the ambient temperature. The experimental results reveal that the proposed sensor placed 50 mm away from a subject can reliably detect respiration and heartbeat signals without the ambiguity of harmonic signals caused by respiration signal at an operating frequency of 2.4 GHz.
Collapse
|
9
|
Mercier PP, Bandyopadhyay S, Lysaght AC, Stankovic KM, Chandrakasan AP. A sub-nW 2.4 GHz Transmitter for Low Data-Rate Sensing Applications. IEEE JOURNAL OF SOLID-STATE CIRCUITS 2014; 49:1463-1474. [PMID: 26246641 PMCID: PMC4523311 DOI: 10.1109/jssc.2014.2316237] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
This paper presents the design of a narrowband transmitter and antenna system that achieves an average power consumption of 78 pW when operating at a duty-cycled data rate of 1 bps. Fabricated in a 0.18 µm CMOS process, the transmitter employs a direct-RF power oscillator topology where a loop antenna acts as a both a radiative and resonant element. The low-complexity single-stage architecture, in combination with aggressive power gating techniques and sizing optimizations, limited the standby power of the transmitter to only 39.7 pW at 0.8 V. Supporting both OOK and FSK modulations at 2.4 GHz, the transmitter consumed as low as 38 pJ/bit at an active-mode data rate of 5 Mbps. The loop antenna and integrated diodes were also used as part of a wireless power transfer receiver in order to kick-start the system power supply during energy harvesting operation.
Collapse
Affiliation(s)
- Patrick P Mercier
- Department of Electrical and Computer Engineering, University of California at San Diego, 9500 Gilman Dr., 0407, La Jolla, CA ( , phone: 858-534-6026)
| | | | - Andrew C Lysaght
- Massachusetts Eye and Ear Infirmary, Boston, MA, and the Harvard/MIT Joint Division of Health Sciences and Technology, Cambridge, MA
| | - Konstantina M Stankovic
- Massachusetts Eye and Ear Infirmary, Boston, MA, and the Harvard/MIT Joint Division of Health Sciences and Technology, Cambridge, MA
| | - Anantha P Chandrakasan
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology (MIT), Cambridge, MA
| |
Collapse
|
10
|
|
11
|
Vidojkovic M, Huang X, Harpe P, Rampu S, Zhou C, Huang L, van de Molengraft J, Imamura K, Busze B, Bouwens F, Konijnenburg M, Santana J, Breeschoten A, Huisken J, Philips K, Dolmans G, de Groot H. A 2.4 GHz ULP OOK Single-Chip Transceiver for Healthcare Applications. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2011; 5:523-534. [PMID: 23852550 DOI: 10.1109/tbcas.2011.2173340] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
This paper describes an ultra-low power (ULP) single chip transceiver for wireless body area network (WBAN) applications. It supports on-off keying (OOK) modulation, and it operates in the 2.36-2.4 GHz medical BAN and 2.4-2.485 GHz ISM bands. It is implemented in 90 nm CMOS technology. The direct modulated transmitter transmits OOK signal with 0 dBm peak power, and it consumes 2.59 mW with 50% OOK. The transmitter front-end supports up to 10 Mbps. The transmitter digital baseband enables digital pulse-shaping to improve spectrum efficiency. The super-regenerative receiver front-end supports up to 5 Mbps with -75 dBm sensitivity. Including the digital part, the receiver consumes 715 μW at 1 Mbps data rate, oversampled at 3 MHz. At the system level the transceiver achieves PER=10 (-2) at 25 meters line of site with 62.5 kbps data rate and 288 bits packet size. The transceiver is integrated in an electrocardiogram (ECG) necklace to monitor the heart's electrical property.
Collapse
|