1
|
Yang J, Shah S, Olson TM, Xu X. Modeling GATAD1-Associated Dilated Cardiomyopathy in Adult Zebrafish. J Cardiovasc Dev Dis 2016; 3. [PMID: 28955713 PMCID: PMC5611887 DOI: 10.3390/jcdd3010006] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Animal models have played a critical role in validating human dilated cardiomyopathy (DCM) genes, particularly those that implicate novel mechanisms for heart failure. However, the disease phenotype may be delayed due to age-dependent penetrance. For this reason, we generated an adult zebrafish model, which is a simpler vertebrate model with higher throughput than rodents. Specifically, we studied the zebrafish homologue of GATAD1, a recently identified gene for adult-onset autosomal recessive DCM. We showed cardiac expression of gatad1 transcripts, by whole mount in situ hybridization in zebrafish embryos, and demonstrated nuclear and sarcomeric I-band subcellular localization of Gatad1 protein in cardiomyocytes, by injecting a Tol2 plasmid encoding fluorescently-tagged Gatad1. We next generated gatad1 knock-out fish lines by TALEN technology and a transgenic fish line that expresses the human DCM GATAD1-S102P mutation in cardiomyocytes. Under stress conditions, longitudinal studies uncovered heart failure (HF)-like phenotypes in stable KO mutants and a tendency toward HF phenotypes in transgenic lines. Based on these efforts of studying a gene-based inherited cardiomyopathy model, we discuss the strengths and bottlenecks of adult zebrafish as a new vertebrate model for assessing candidate cardiomyopathy genes.
Collapse
Affiliation(s)
- Jingchun Yang
- Department of Biochemistry and Molecular Biology, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA; (J.Y.); (S.S.)
| | - Sahrish Shah
- Department of Biochemistry and Molecular Biology, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA; (J.Y.); (S.S.)
| | - Timothy M. Olson
- Department of Internal Medicine, Division of Cardiovascular Diseases, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA;
- Department of Pediatrics and Adolescent Medicine, Division of Pediatric Cardiology, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA
| | - Xiaolei Xu
- Department of Biochemistry and Molecular Biology, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA; (J.Y.); (S.S.)
- Department of Internal Medicine, Division of Cardiovascular Diseases, Mayo Clinic College of Medicine, 200 First St. SW Rochester, MN 55905, USA;
- Correspondence: ; Tel.: +1-507-284-0685; Fax: +1-507-538-6418
| |
Collapse
|
2
|
Jafari S, Diou O, Mamou J, Renault G, Fattal E, Tsapis N, Bridal SL. High-frequency (20 to 40 MHz) acoustic response of liquid-filled nanocapsules. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2014; 61:5-15. [PMID: 24402891 DOI: 10.1109/tuffc.2014.6689771] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Liquid-core nanoparticles are promising candidates for targeted ultrasound-controlled therapy, but their acoustic detection remains challenging. High-frequency (20 to 40 MHz) tone burst sequences were implemented with a programmable ultrasound biomicroscope to characterize acoustic response from perfluorooctyl bromide-core nanoparticles with thick poly(lactide-coglycolide) (PLGA) shells. Radio-frequency signals were acquired from flowing solutions of nanoparticles with two different shell-thickness-to-particle-radius ratios, solid PLGA nanoparticles, and latex nanobeads (linear controls). Normalized fundamental (20 MHz) and second-harmonic power spectral density (PSD) increased with particle concentration and was highest for the thinnest shelled particles. The second- harmonic PSD was detectable from the nanoparticles for peak rarefactional pressures (PRP) from 0.97 to 2.01 MPa at 23 cycles and for tone bursts from 11 to 23 cycles at 2.01 MPa. Their second-harmonic¿to¿fundamental ratio increased as a function of PRP and number of cycles. Within the same PRP and cycle ranges, the second-harmonic¿to¿fundamental ratios from matched concentration solutions of latex nanobeads and solid PLGA nanoparticles was more weakly detectable but also increased with PRP and number of cycles. Nanoparticles were detectable under flow conditions in vitro using the contrast agent mode of a high-frequency commercial scanner. These results characterize linear acoustic response from the nanoparticles (20 to 40 MHz) and demonstrate potential for their highfrequency detection.
Collapse
|
3
|
Qiu W, Yu Y, Tsang FK, Zheng H, Sun L. A novel modulated excitation imaging system for microultrasound. IEEE Trans Biomed Eng 2013; 60:1884-90. [PMID: 23380848 DOI: 10.1109/tbme.2013.2244887] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Microultrasound (micro-US), also known as ultrasound biomicroscope, is able to delineate small structures with fine spatial resolution. However, micro-US suffers limited depth of penetration due to significantly large attenuation at high frequencies. Modulated excitation imaging has displayed the capability to improve the penetration depth, while maintaining the spatial resolution. But the effectiveness of this technique in micro-US has not been fully demonstrated. In addition, the current modulated excitation imaging systems for micro-US are designed for specific excitation method, therefore, lack of flexibility, and are typically bulky and expensive. This paper presents the development of a novel system to achieve modulated excitation imaging with high programmability and flexibility to satisfy various micro-US studies. It incorporates a high-voltage arbitrary waveform generator for producing desired excitation waveform, and a programmable imaging receiver implemented by the state-of-the-art electronics and field-programmable gate array. Test results show that the proposed modulated excitation imaging system can acquire up to 20 dB signal-to-noise ratio improvement and 83% increase of penetration depth in contrast to traditional short-pulse imaging method. In vivo experiment on the dorsal skin of a human hand demonstrates good performance of the programmable modulated excitation imaging system.
Collapse
Affiliation(s)
- Weibao Qiu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China.
| | | | | | | | | |
Collapse
|
4
|
Ultrasonic strategies to monitor drug delivery. J Drug Deliv Sci Technol 2013. [DOI: 10.1016/s1773-2247(13)50006-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
5
|
Qiu W, Yu Y, Tsang F, Sun L. A multifunctional, reconfigurable pulse generator for high-frequency ultrasound imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:1558-1567. [PMID: 22828850 DOI: 10.1109/tuffc.2012.2355] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
High-frequency (>20 MHz) ultrasound (HFUS) imaging systems have made it possible to image small structures with fine spatial resolution. They find a variety of biomedical applications in dermatology, ophthalmology, intravascular imaging, and small-animal imaging. One critical technical challenge of HFUS is to generate high-voltage, high-frequency pulsed signals to effectively excite the transducer for a high SNR. This paper presents the development of a multifunctional, reconfigurable pulse generator for HFUS imaging. The pulse generator can produce a high-voltage unipolar pulse, a bipolar pulse, or arbitrary pulses for B-mode imaging, Doppler measurement, and modulated excitation imaging. The characteristics of the pulses, such as timing, waveform, and frequency are reconfigurable by a high-speed field-programmable gate array (FPGA). Customized software was developed to interface with the FPGA through a USB connector for pulse selection, and easy, flexible, real-time pulse management. The hardware was implemented in a compact, printed circuit board (PCB)-based scheme using state-of-the-art electronics for costeffectiveness and fully digital control. Testing results show that the unipolar pulse can reach over 165 Vpp with a 6-dB bandwidth of 70 MHz, and the bipolar pulse and arbitrary pulses can reach 150 and 60 Vpp with central frequencies of 60 and 120 MHz, respectively.
Collapse
Affiliation(s)
- Weibao Qiu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | | | | | | |
Collapse
|
6
|
Qiu W, Yu Y, Tsang F, Sun L. An FPGA-based open platform for ultrasound biomicroscopy. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:1432-1442. [PMID: 22828839 DOI: 10.1109/tuffc.2012.2344] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
Ultrasound biomicroscopy (UBM) has been extensively applied to preclinical studies in small animal models. Individual animal study is unique and requires different utilization of the UBM system to accommodate different transducer characteristics, data acquisition strategies, signal processing, and image reconstruction methods. There is a demand for a flexible and open UBM platform to allow users to customize the system for various studies and have full access to experimental data. This paper presents the development of an open UBM platform (center frequency 20 to 80 MHz) for various preclinical studies. The platform design was based on a field-programmable gate array (FPGA) embedded in a printed circuit board to achieve B-mode imaging and directional pulsed-wave Doppler. Instead of hardware circuitry, most functions of the platform, such as filtering, envelope detection, and scan conversion, were achieved by FPGA programs; thus, the system architecture could be easily modified for specific applications. In addition, a novel digital quadrature demodulation algorithm was implemented for fast and accurate Doppler profiling. Finally, test results showed that the platform could offer a minimum detectable signal of 25 μV, allowing a 51 dB dynamic range at 47 dB gain, and real-time imaging at more than 500 frames/s. Phantom and in vivo imaging experiments were conducted and the results demonstrated good system performance.
Collapse
Affiliation(s)
- Weibao Qiu
- Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China
| | | | | | | |
Collapse
|
7
|
Park J, Hu C, Li X, Zhou Q, Shung KK. Wideband linear power amplifier for high-frequency ultrasonic coded excitation imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2012; 59:825-32. [PMID: 22547294 DOI: 10.1109/tuffc.2012.2261] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Linear power amplifiers are critical components in ultrasonic imaging systems that implement chirp-coded excitation. Bench-top commercial power amplifiers are usually used in academic laboratories for high-frequency ultrasound imaging, and the imaging performance depends greatly on these general-purpose instruments. To achieve a wide dynamic range, a power amplifier consisting of two stages is developed for chirp-coded ultrasound imaging applications through the implementation of custom-designed broadband 1:1 transformers and the optimization of feedback circuits. The amplifier has broad bandwidth (5 to 135 MHz), maintaining a linearity up to the 1-dB gain compression point (P1dB) of 41.5 dBm, allowing 16 dBm input power level at 60 MHz. The mean and the maximum values of output third-order intercept points (OIP3) are 51.8 and 53.5 dBm, respectively, between 20 and 110 MHz. With 12 dBm input power, the gain of the amplifier varies between 24 and 29 dB, offering a uniformity which would allow excitation of a 70-MHz single-element transducer with windowed chirp-coded bursts sweeping from 40 to 100 MHz. The performance in high-frequency ultrasound imaging is evaluated with a wire phantom. Echo signal-to-noise ratio (eSNR) of the designed amplifier is 7 dB better than a commercial amplifier, and spatial resolution is maintained.
Collapse
|
8
|
Park J, Hu C, Shung KK. Stand-alone front-end system for high- frequency, high-frame-rate coded excitation ultrasonic imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2011; 58:2620-2630. [PMID: 23443698 PMCID: PMC3589806 DOI: 10.1109/tuffc.2011.2125] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A stand-alone front-end system for high-frequency coded excitation imaging was implemented to achieve a wider dynamic range. The system included an arbitrary waveform amplifier, an arbitrary waveform generator, an analog receiver, a motor position interpreter, a motor controller and power supplies. The digitized arbitrary waveforms at a sampling rate of 150 MHz could be programmed and converted to an analog signal. The pulse was subsequently amplified to excite an ultrasound transducer, and the maximum output voltage level achieved was 120 V(pp). The bandwidth of the arbitrary waveform amplifier was from 1 to 70 MHz. The noise figure of the preamplifier was less than 7.7 dB and the bandwidth was 95 MHz. Phantoms and biological tissues were imaged at a frame rate as high as 68 frames per second (fps) to evaluate the performance of the system. During the measurement, 40-MHz lithium niobate (LiNbO(3)) single-element lightweight (<;0.28 g) transducers were utilized. The wire target measure- ment showed that the -6-dB axial resolution of a chirp-coded excitation was 50 μm and lateral resolution was 120 μm. The echo signal-to-noise ratios were found to be 54 and 65 dB for the short burst and coded excitation, respectively. The contrast resolution in a sphere phantom study was estimated to be 24 dB for the chirp-coded excitation and 15 dB for the short burst modes. In an in vivo study, zebrafish and mouse hearts were imaged. Boundaries of the zebrafish heart in the image could be differentiated because of the low-noise operation of the implemented system. In mouse heart images, valves and chambers could be readily visualized with the coded excitation.
Collapse
Affiliation(s)
- Jinhyoung Park
- NIH Resource on Medical Ultrasonic Transducer Technology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, USA.
| | | | | |
Collapse
|