1
|
Fan Q, Jiang L, El Gohary A, Dong F, Wu D, Jiang T, Wang C, Liu J. A multi-domain feature fusion epilepsy seizure detection method based on spike matching and PLV functional networks. J Neural Eng 2025; 22:016025. [PMID: 39870038 DOI: 10.1088/1741-2552/adaef3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/02/2024] [Accepted: 01/27/2025] [Indexed: 01/29/2025]
Abstract
Objective.The identification of spikes, as a typical characteristic wave of epilepsy, is crucial for diagnosing and locating the epileptogenic region. The traditional seizure detection methods lack spike features and have low sample richness. This paper proposes a seizure detection method with spike-based phase locking value (PLV) functional brain networks and multi-domain fused features.Approach.In the spiking detection part, brain functional networks based on PLV are constructed to explore the changes in brain functional states during spiking discharge, from the perspective of microscopic neuronal activity to macroscopic brain region interactions. Then, in the epilepsy seizure detection task, multi-domain fused feature sequences are constructed using time-domain, frequency-domain, inter-channel correlation, and the spike detection features. Finally, Bi-LSTM and Transformer encoders and their optimized models are used to verify the effectiveness of the proposed method.Main results.Experimental results achieve the best seizure detection metrics on Bi-LSTM-Attention, with accuracy, sensitivity, and specificity reaching 98.40%, 98.94%, and 97.86%, respectively.Significance.The method is significant as it innovatively applies multi channel spike network features to seizure detection. It can potentially improve the diagnosis and location of the epileptogenic region by accurately detecting seizures through the identification of spikes, which is a crucial characteristic wave of epilepsy.
Collapse
Affiliation(s)
- Qikai Fan
- School of Information Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, People's Republic of China
- Provincial Key Laboratory for Research and Translation of Kidney Deficiency-Stasis-Turbidity Disease, Hangzhou 310018, People's Republic of China
| | - Lurong Jiang
- School of Information Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, People's Republic of China
- Provincial Key Laboratory for Research and Translation of Kidney Deficiency-Stasis-Turbidity Disease, Hangzhou 310018, People's Republic of China
| | - Amira El Gohary
- Department of Neurology, Cairo University, Cairo 12311, Egypt
| | - Fang Dong
- College of Information and Electric Engineering, Hangzhou City University, Hangzhou 310015, People's Republic of China
| | - Duanpo Wu
- School of Communication Engineering, Hangzhou Dianzi University, Hangzhou 310052, People's Republic of China
| | - Tiejia Jiang
- Department of Neurology, The Children's Hospital, Zhejiang University School of Medicine, National Clinical Research Center for Child Health, Hangzhou, People's Republic of China
| | - Chen Wang
- School of Information Science and Engineering, Zhejiang Sci-Tech University, Hangzhou 310018, People's Republic of China
- Provincial Key Laboratory for Research and Translation of Kidney Deficiency-Stasis-Turbidity Disease, Hangzhou 310018, People's Republic of China
| | - Junbiao Liu
- School of Automation, Hangzhou Dianzi University, Hangzhou 310052, People's Republic of China
| |
Collapse
|
2
|
Atal DK, Singh M. Effectual seizure detection using MBBF-GPSO with CNN network. Cogn Neurodyn 2024; 18:907-918. [PMID: 38826653 PMCID: PMC11143161 DOI: 10.1007/s11571-023-09943-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2022] [Revised: 12/23/2022] [Accepted: 02/05/2023] [Indexed: 03/02/2023] Open
Abstract
EEG is the most common test for diagnosing a seizure, where it presents information about the electrical activity of the brain. Automatic Seizure detection is one of the challenging tasks due to limitations of conventional methods with regard to inefficient feature selection, increased computational complexity and time and less accuracy. The situation calls for a practical framework to achieve better performance for detecting the seizure effectively. Hence, this study proposes modified Blackman bandpass filter-greedy particle swarm optimization (MBBF-GPSO) with convolutional neural network (CNN) for effective seizure detection. In this case, unwanted signals (noise) is eliminated by MBBF as it possess better ability in stopband attenuation, and, only the optimized features are selected using GPSO. For enhancing the efficacy of obtaining optimal solutions in GPSO, the time and frequency domain is extracted to complement it. Through this process, an optimized features are attained by MBBF-GPSO. Then, the CNN layer is employed for obtaining the productive classification output using the objective function. Here, CNN is employed due to its ability in automatically learning distinct features for individual class. Such advantages of the proposed system have made it explore better performance in seizure detection that is confirmed through performance and comparative analysis.
Collapse
Affiliation(s)
- Dinesh Kumar Atal
- Department of Electrical Engineering, Delhi Technological University, Bawana Road, Delhi, 110042 India
| | - Mukhtiar Singh
- Department of Electrical Engineering, Delhi Technological University, Bawana Road, Delhi, 110042 India
| |
Collapse
|
3
|
Chaibi S, Mahjoub C, Ayadi W, Kachouri A. Epileptic EEG patterns recognition through machine learning techniques and relevant time-frequency features. BIOMED ENG-BIOMED TE 2024; 69:111-123. [PMID: 37899292 DOI: 10.1515/bmt-2023-0332] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 10/09/2023] [Indexed: 10/31/2023]
Abstract
OBJECTIVES The present study is designed to explore the process of epileptic patterns' automatic detection, specifically, epileptic spikes and high-frequency oscillations (HFOs), via a selection of machine learning (ML) techniques. The primary motivation for conducting such a research lies mainly in the need to investigate the long-term electroencephalography (EEG) recordings' visual examination process, often considered as a time-consuming and potentially error-prone procedure, requiring a great deal of mental focus and highly experimented neurologists. On attempting to resolve such a challenge, a number of state-of-the-art ML algorithms have been evaluated and compare in terms of performance, to pinpoint the most effective algorithm fit for accurately extracting epileptic EEG patterns. CONTENT Based on intracranial as well as simulated EEG data, the attained findings turn out to reveal that the randomforest (RF) method proved to be the most consistently effective approach, significantly outperforming the entirety of examined methods in terms of EEG recordings epileptic-pattern identification. Indeed, the RF classifier appeared to record an average balanced classification rate (BCR) of 92.38 % in regard to spikes recognition process, and 78.77 % in terms of HFOs detection. SUMMARY Compared to other approaches, our results provide valuable insights into the RF classifier's effectiveness as a powerful ML technique, fit for detecting EEG signals born epileptic bursts. OUTLOOK As a potential future work, we envisage to further validate and sustain our major reached findings through incorporating a larger EEG dataset. We also aim to explore the generative adversarial networks (GANs) application so as to generate synthetic EEG signals or combine signal generation techniques with deep learning approaches. Through this new vein of thought, we actually preconize to enhance and boost the automated detection methods' performance even more, thereby, noticeably enhancing the epileptic EEG pattern recognition area.
Collapse
Affiliation(s)
- Sahbi Chaibi
- AFD2E Laboratory, National Engineering School, Sfax University, Sfax, Tunisia
- Faculty of Sciences of Monastir, Monastir University, Monastir, Tunisia
| | - Chahira Mahjoub
- AFD2E Laboratory, National Engineering School, Sfax University, Sfax, Tunisia
| | - Wadhah Ayadi
- Faculty of Sciences of Monastir, Monastir University, Monastir, Tunisia
| | | |
Collapse
|
4
|
Wu JCH, Liao NC, Yang TH, Hsieh CC, Huang JA, Pai YW, Huang YJ, Wu CL, Lu HHS. Deep-Learning-Based Automated Anomaly Detection of EEGs in Intensive Care Units. Bioengineering (Basel) 2024; 11:421. [PMID: 38790288 PMCID: PMC11118603 DOI: 10.3390/bioengineering11050421] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 04/20/2024] [Accepted: 04/23/2024] [Indexed: 05/26/2024] Open
Abstract
An intensive care unit (ICU) is a special ward in the hospital for patients who require intensive care. It is equipped with many instruments monitoring patients' vital signs and supported by the medical staff. However, continuous monitoring demands a massive workload of medical care. To ease the burden, we aim to develop an automatic detection model to monitor when brain anomalies occur. In this study, we focus on electroencephalography (EEG), which monitors the brain electroactivity of patients continuously. It is mainly for the diagnosis of brain malfunction. We propose the gated-recurrent-unit-based (GRU-based) model for detecting brain anomalies; it predicts whether the spike or sharp wave happens within a short time window. Based on the banana montage setting, the proposed model exploits characteristics of multiple channels simultaneously to detect anomalies. It is trained, validated, and tested on separated EEG data and achieves more than 90% testing performance on sensitivity, specificity, and balanced accuracy. The proposed anomaly detection model detects the existence of a spike or sharp wave precisely; it will notify the ICU medical staff, who can provide immediate follow-up treatment. Consequently, it can reduce the medical workload in the ICU significantly.
Collapse
Affiliation(s)
- Jacky Chung-Hao Wu
- Institute of Statistics, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan; (J.C.-H.W.); (T.-H.Y.); (C.-C.H.)
| | - Nien-Chen Liao
- Department of Critical Care Medicine, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (N.-C.L.); (Y.-J.H.)
- Department of Neurology, Neurological Institute, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (J.-A.H.); (Y.-W.P.)
- Institute of Clinical Medicine, National Yang Ming Chiao Tung University, Taipei 112304, Taiwan
| | - Ta-Hsin Yang
- Institute of Statistics, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan; (J.C.-H.W.); (T.-H.Y.); (C.-C.H.)
| | - Chen-Cheng Hsieh
- Institute of Statistics, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan; (J.C.-H.W.); (T.-H.Y.); (C.-C.H.)
| | - Jin-An Huang
- Department of Neurology, Neurological Institute, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (J.-A.H.); (Y.-W.P.)
- Department of Health Business Administration, Hungkuang University, Taichung 433304, Taiwan
| | - Yen-Wei Pai
- Department of Neurology, Neurological Institute, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (J.-A.H.); (Y.-W.P.)
- Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung 402202, Taiwan
| | - Yi-Jhen Huang
- Department of Critical Care Medicine, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (N.-C.L.); (Y.-J.H.)
| | - Chieh-Liang Wu
- Department of Critical Care Medicine, Taichung Veterans General Hospital, Taichung 407219, Taiwan; (N.-C.L.); (Y.-J.H.)
- Department of Post-Baccalaureate Medicine, College of Medicine, National Chung Hsing University, Taichung 402202, Taiwan
| | - Henry Horng-Shing Lu
- Institute of Statistics, National Yang Ming Chiao Tung University, Hsinchu 300093, Taiwan; (J.C.-H.W.); (T.-H.Y.); (C.-C.H.)
- Department of Statistics and Data Science, Cornell University, Ithaca, NY 14853, USA
| |
Collapse
|
5
|
Abdi-Sargezeh B, Shirani S, Sanei S, Took CC, Geman O, Alarcon G, Valentin A. A review of signal processing and machine learning techniques for interictal epileptiform discharge detection. Comput Biol Med 2024; 168:107782. [PMID: 38070202 DOI: 10.1016/j.compbiomed.2023.107782] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 11/15/2023] [Accepted: 11/28/2023] [Indexed: 01/10/2024]
Abstract
Brain interictal epileptiform discharges (IEDs), as one of the hallmarks of epileptic brain, are transient events captured by electroencephalogram (EEG). IEDs are generated by seizure networks, and they occur between seizures (interictal periods). The development of a robust method for IED detection could be highly informative for clinical treatment procedures and epileptic patient management. Since 1972, different machine learning techniques, from template matching to deep learning, have been developed to automatically detect IEDs from scalp EEG (scEEG) and intracranial EEG (iEEG). While the scEEG signals suffer from low information details and high attenuation of IEDs due to the high skull electrical impedance, the iEEG signals recorded using implanted electrodes enjoy higher details and are more suitable for identifying the IEDs. In this review paper, we group IED detection techniques into six categories: (1) template matching, (2) feature representation (mimetic, time-frequency, and nonlinear features), (3) matrix decomposition, (4) tensor factorization, (5) neural networks, and (6) estimation of the iEEG from the concurrent scEEG followed by detection and classification. The methods are compared quantitatively (e.g., in terms of accuracy, sensitivity, and specificity), and their general advantages and limitations are described. Finally, current limitations and possible future research paths related to this field are mentioned.
Collapse
Affiliation(s)
- Bahman Abdi-Sargezeh
- Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford, UK; School of Science and Technology, Nottingham Trent University, Nottingham, UK.
| | - Sepehr Shirani
- School of Science and Technology, Nottingham Trent University, Nottingham, UK
| | - Saeid Sanei
- School of Science and Technology, Nottingham Trent University, Nottingham, UK
| | - Clive Cheong Took
- Department of Electronic Engineering, Royal Holloway, University of London, London, UK
| | - Oana Geman
- Computer, Electronics and Automation Department, University Stefan cel Mare, Suceava, Romania
| | - Gonzalo Alarcon
- Department of Clinical Neurophysiology, Royal Manchester Children's Hospital, Manchester, UK
| | - Antonio Valentin
- Department of Clinical Neuroscience, King's College London, London, UK
| |
Collapse
|
6
|
Epileptic seizure focus detection from interictal electroencephalogram: a survey. Cogn Neurodyn 2023; 17:1-23. [PMID: 36704629 PMCID: PMC9871145 DOI: 10.1007/s11571-022-09816-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 04/15/2022] [Accepted: 04/21/2022] [Indexed: 01/29/2023] Open
Abstract
Electroencephalogram (EEG) is one of most effective clinical diagnosis modalities for the localization of epileptic focus. Most current AI solutions use this modality to analyze the EEG signals in an automated manner to identify the epileptic seizure focus. To develop AI system for identifying the epileptic focus, there are many recently-published AI solutions based on biomarkers or statistic features that utilize interictal EEGs. In this review, we survey these solutions and find that they can be divided into three main categories: (i) those that use of biomarkers in EEG signals, including high-frequency oscillation, phase-amplitude coupling, and interictal epileptiform discharges, (ii) others that utilize feature-extraction methods, and (iii) solutions based upon neural networks (an end-to-end approach). We provide a detailed description of seizure focus with clinical diagnosis methods, a summary of the public datasets that seek to reduce the research gap in epilepsy, recent novel performance evaluation criteria used to evaluate the AI systems, and guidelines on when and how to use them. This review also suggests a number of future research challenges that must be overcome in order to design more efficient computer-aided solutions to epilepsy focus detection.
Collapse
|
7
|
Kleeva D, Soghoyan G, Komoltsev I, Sinkin M, Ossadtchi A. Fast parametric curve matching (FPCM) for automatic spike detection. J Neural Eng 2022; 19. [PMID: 35439749 DOI: 10.1088/1741-2552/ac682a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Accepted: 04/18/2022] [Indexed: 11/12/2022]
Abstract
Epilepsy is a widely spread neurological disease, whose treatment often requires resection of the pathological cortical tissue. Interictal spike analysis observed in the non-invasively collected EEG or MEG data offers a way to localize epileptogenic cortical structures for surgery planning purposes. While a plethora of automatic spike detection techniques have been developed each with its own assumptions and limitations, non of them is ideal and the best results are achieved when the output of several automatic spike detectors are combined. This is especially true in the low signal-to-noise ratio conditions. To this end we propose a novel biomimetic approach for automatic spike detection based on a constrained mixed spline machinery that we dub as fast parametric curve matching (FPCM). Using the peak-wave shape parametrization, the constrained parametric morphological model is constructed and convolved with the observed multichannel data to very efficiently determine mixed spline parameters corresponding to each time-point in the dataset. Then the logical predicates that directly map to the expected interictal event morphology allow us to accomplish the spike detection task. The results of simulations mimicking typical low SNR scenario show the robustness and high ROC AUC values of the FPCM method as compared to the spike detection performed by the means of more conventional approaches such as wavelet decomposition, template matching or simple amplitude thresholding. Applied to the real MEG and EEG data from the human patients and to ECoG data from the rat, the FPCM technique demonstrates reliable detection of the interictal events and localization of epileptogenic zones concordant with independent conclusions made by the epileptologist. Since the FPCM is computationally light, tolerant to high amplitude artifacts and flexible to accommodate verbalized descriptions of the arbitrary target morphology, it may complement the existing arsenal of means for analysis of noisy interictal datasets.
Collapse
Affiliation(s)
- Daria Kleeva
- Center for Bioelectric Interfaces, Higher School of Economics, Moscow, Russia
| | - Gurgen Soghoyan
- Center for Bioelectric Interfaces, Higher School of Economics, Moscow, Russia
| | - Ilia Komoltsev
- Laboratory of Functional Biochemistry of the Nervous System, Institute of Higher Nervous Activity and Neurophysiology, Russian Academy of Sciences, Moscow, Russia.,Moscow Research and Clinical Center for Neuropsychiatry of the Healthcare Department of Moscow, Moscow, Russia
| | - Mikhail Sinkin
- A I Evdokimov Moscow State University of Medicical Dentistry, Moscow, Russia.,N V Sklifosovsky Research Institute of Emergency Medicine, Moscow, Russia
| | - Alexei Ossadtchi
- Center for Bioelectric Interfaces, Higher School of Economics, Moscow, Russia.,AIRI, Artificial Intelligence Research Institute, Moscow, Russia
| |
Collapse
|
8
|
Geng D, Alkhachroum A, Melo Bicchi M, Jagid J, Cajigas I, Chen ZS. Deep learning for robust detection of interictal epileptiform discharges. J Neural Eng 2021; 18. [PMID: 33770777 DOI: 10.1088/1741-2552/abf28e] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Accepted: 03/26/2021] [Indexed: 01/13/2023]
Abstract
OBJECTIVE Automatic detection of interictal epileptiform discharges (IEDs, short as ``spikes'') from an epileptic brain can help predict seizure recurrence and support the diagnosis of epilepsy. Developing fast, reliable and robust detection methods for IEDs based on scalp or intracortical EEG may facilitate online seizure monitoring and closed-loop neurostimulation. APPROACH We developed a new deep learning approach, which employs a long short-term memory (LSTM) network architecture (``IEDnet'') and an auxiliary classifier generative adversarial network (AC-GAN), to train on both expert-annotated and augmented spike events from intracranial electroencephalography (iEEG) recordings of epilepsy patients. We validated our IEDnet with two real-world iEEG datasets, and compared IEDnet with the support vector machine (SVM) and random forest (RF) classifiers on their detection performances. MAIN RESULTS IEDnet achieved excellent cross-validated detection performances in terms of both sensitivity and specificity, and outperformed SVM and RF. Synthetic spike samples augmented by AC-GAN further improved the detection performance. In addition, the performance of IEDnet was robust with respect to the sampling frequency and noise. Furthermore, we also demonstrated the cross-institutional generalization ability of IEDnet while testing between two datasets. SIGNIFICANCE IEDnet achieves excellent detection performances in identifying interictal spikes. AC-GAN can produce augmented iEEG samples to improve supervised deep learning.
Collapse
Affiliation(s)
- David Geng
- New York University School of Medicine, One Park Avenue, New York, New York, 10016-6402, UNITED STATES
| | - Ayham Alkhachroum
- University of Miami Miller School of Medicine, 1600 NW 10th Avenue, Miami, Florida, 33136-1015, UNITED STATES
| | - Manuel Melo Bicchi
- University of Miami Miller School of Medicine, 1600 NW 10th Avenue, Miami, Florida, 33136-1015, UNITED STATES
| | - Jonathan Jagid
- University of Miami Miller School of Medicine, 1600 NW 10th Avenue, Miami, Florida, 33136-1015, UNITED STATES
| | - Iahn Cajigas
- Department of Neurological Surgery, University of Miami Miller School of Medicine, 1095 NW 14th Ter # D4-6, Miami, Miami, Florida, 33136-1060, UNITED STATES
| | - Zhe Sage Chen
- Psychiatry, New York University School of Medicine, One Park Avenue, Rm 226, New York, New York, 10016, UNITED STATES
| |
Collapse
|
9
|
Yıldırım S, Koçer HE, Ekmekçi AH. Automatic phase reversal detection in routine EEG. Med Hypotheses 2020; 142:109825. [DOI: 10.1016/j.mehy.2020.109825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2020] [Revised: 04/16/2020] [Accepted: 05/06/2020] [Indexed: 11/24/2022]
|
10
|
Mesin L, Valerio M, Capizzi G. Automated diagnosis of encephalitis in pediatric patients using EEG rhythms and slow biphasic complexes. Phys Eng Sci Med 2020; 43:997-1006. [PMID: 32696434 DOI: 10.1007/s13246-020-00893-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2020] [Accepted: 06/29/2020] [Indexed: 11/25/2022]
Abstract
Slow biphasic complexes (SBC) have been identified in the EEG of patients suffering for inflammatory brain diseases. Their amplitude, location and frequency of appearance were found to correlate with the severity of encephalitis. Other characteristics of SBCs and of EEG traces of patients could reflect the grade of pathology. Here, EEG rhythms are investigated together with SBCs for a better characterization of encephalitis. EEGs have been acquired from pediatric patients: ten controls and ten encephalitic patients. They were split by neurologists into five classes of different severity of the pathology. The relative power of EEG rhythms was found to change significantly in EEGs labeled with different severity scores. Moreover, a significant variation was found in the last seconds before the appearance of an SBC. This information and quantitative indexes characterizing the SBCs were used to build a binary classification decision tree able to identify the classes of severity. True classification rate of the best model was 76.1% (73.5% with leave-one-out test). Moreover, the classification errors were among classes with similar severity scores (precision higher than 80% was achieved considering three instead of five classes). Our classification method may be a promising supporting tool for clinicians to diagnose, assess and make the follow-up of patients with encephalitis.
Collapse
Affiliation(s)
- Luca Mesin
- Mathematical Biology and Physiology, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Turin, Italy.
| | - Massimo Valerio
- Mathematical Biology and Physiology, Department of Electronics and Telecommunications, Politecnico di Torino, Corso Duca degli Abruzzi 24, 10129, Turin, Italy
| | - Giorgio Capizzi
- Ospedale Infantile Regina Margherita, Department of Child Neuropsychiatry, Universitá di Torino, Turin, Italy
| |
Collapse
|
11
|
Zheng L, Liao P, Luo S, Sheng J, Teng P, Luan G, Gao JH. EMS-Net: A Deep Learning Method for Autodetecting Epileptic Magnetoencephalography Spikes. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:1833-1844. [PMID: 31831410 DOI: 10.1109/tmi.2019.2958699] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
Epilepsy is a neurological disorder characterized by sudden and unpredictable epileptic seizures, which incurs significant negative impacts on patients' physical, psychological and social health. A practical approach to assist with the clinical assessment and treatment planning for patients is to process magnetoencephalography (MEG) data to identify epileptogenic zones. As a widely accepted biomarker of epileptic foci, epileptic MEG spikes need to be precisely detected. Given that the visual inspection of spikes is time consuming, an automatic and efficient system with adequate accuracy for spike detection is valuable in clinical practice. However, current approaches for MEG spike autodetection are dependent on hand-engineered features. Here, we propose a novel multiview Epileptic MEG Spikes detection algorithm based on a deep learning Network (EMS-Net) to accurately and efficiently recognize the spike events from MEG raw data. The results of the leave-k-subject-out validation tests for multiple datasets (i.e., balanced and realistic datasets) showed that EMS-Net achieved state-of-the-art classification performance (i.e., accuracy: 91.82% - 99.89%; precision: 91.90% - 99.45%; sensitivity: 91.61% - 99.53%; specificity: 91.60% - 99.96%; f1 score: 91.70% - 99.48%; and area under the curve: 0.9688 - 0.9998).
Collapse
|
12
|
Mesin L, Valerio M, Beaumanoir A, Capizzi G. Automatic identification of slow biphasic complexes in EEG: an effective tool to detect encephalitis. Biomed Phys Eng Express 2019. [DOI: 10.1088/2057-1976/ab2086] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
13
|
Sriraam N, Raghu S, Tamanna K, Narayan L, Khanum M, Hegde AS, Kumar AB. Automated epileptic seizures detection using multi-features and multilayer perceptron neural network. Brain Inform 2018; 5:10. [PMID: 30175391 PMCID: PMC6170940 DOI: 10.1186/s40708-018-0088-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2018] [Accepted: 08/10/2018] [Indexed: 11/12/2022] Open
Abstract
Detection of epileptic seizure activities from long-term multi-channel electroencephalogram (EEG) signals plays a significant role in the timely treatment of the patients with epilepsy. Visual identification of epileptic seizure in long-term EEG is cumbersome and tedious for neurologists, which might also lead to human error. Therefore, an automated tool for accurate detection of seizures in a long-term multi-channel EEG is essential for the clinical diagnosis. This study proposes an algorithm using multi-features and multilayer perceptron neural network (MLPNN) classifier. After appropriate approval from the ethical committee, recordings of EEG data were collected from the Institute of Neurosciences, Ramaiah Memorial College and Hospital, Bengaluru. Initially, preprocessing was performed to remove the power-line noise and motion artifacts. Four features, namely power spectral density (Yule–Walker), entropy (Shannon and Renyi), and Teager energy, were extracted. The Wilcoxon rank-sum test and descriptive analysis ensure the suitability of the proposed features for pattern classification. Single and multi-features were fed to the MLPNN classifier to evaluate the performance of the study. The simulation results showed sensitivity, specificity, and false detection rate of 97.1%, 97.8%, and 1 h−1, respectively, using multi-features. Further, the results indicate the proposed study is suitable for real-time seizure recognition from multi-channel EEG recording. The graphical user interface was developed in MATLAB to provide an automated biomarker for normal and epileptic EEG signals.
Collapse
Affiliation(s)
- N Sriraam
- Centre for Medical Electronics and Computing, Ramaiah Institute of Technology (Affiliated to VTU Belgaum), Bengaluru, India.
| | - S Raghu
- Centre for Medical Electronics and Computing, Ramaiah Institute of Technology (Affiliated to VTU Belgaum), Bengaluru, India
| | - Kadeeja Tamanna
- Centre for Medical Electronics and Computing, Ramaiah Institute of Technology (Affiliated to VTU Belgaum), Bengaluru, India
| | - Leena Narayan
- Centre for Medical Electronics and Computing, Ramaiah Institute of Technology (Affiliated to VTU Belgaum), Bengaluru, India
| | - Mehraj Khanum
- Centre for Medical Electronics and Computing, Ramaiah Institute of Technology (Affiliated to VTU Belgaum), Bengaluru, India
| | - A S Hegde
- Institute of Neuroscience, Ramaiah Medical College and Hospitals, Bengaluru, India
| | - Anjani Bhushan Kumar
- Institute of Neuroscience, Ramaiah Medical College and Hospitals, Bengaluru, India
| |
Collapse
|
14
|
Abd El-Samie FE, Alotaiby TN, Khalid MI, Alshebeili SA, Aldosari SA. A Review of EEG and MEG Epileptic Spike Detection Algorithms. IEEE ACCESS 2018; 6:60673-60688. [DOI: 10.1109/access.2018.2875487] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/02/2023]
|
15
|
Epileptic MEG Spike Detection Using Statistical Features and Genetic Programming with KNN. JOURNAL OF HEALTHCARE ENGINEERING 2017; 2017:3035606. [PMID: 29118962 PMCID: PMC5651155 DOI: 10.1155/2017/3035606] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/18/2017] [Revised: 08/06/2017] [Accepted: 09/13/2017] [Indexed: 11/18/2022]
Abstract
Epilepsy is a neurological disorder that affects millions of people worldwide. Monitoring the brain activities and identifying the seizure source which starts with spike detection are important steps for epilepsy treatment. Magnetoencephalography (MEG) is an emerging epileptic diagnostic tool with high-density sensors; this makes manual analysis a challenging task due to the vast amount of MEG data. This paper explores the use of eight statistical features and genetic programing (GP) with the K-nearest neighbor (KNN) for interictal spike detection. The proposed method is comprised of three stages: preprocessing, genetic programming-based feature generation, and classification. The effectiveness of the proposed approach has been evaluated using real MEG data obtained from 28 epileptic patients. It has achieved a 91.75% average sensitivity and 92.99% average specificity.
Collapse
|
16
|
Multichannel interictal spike activity detection using time–frequency entropy measure. AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE 2017; 40:413-425. [DOI: 10.1007/s13246-017-0550-6] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2016] [Accepted: 04/05/2017] [Indexed: 11/26/2022]
|
17
|
Jing J, Dauwels J, Rakthanmanon T, Keogh E, Cash SS, Westover MB. Rapid annotation of interictal epileptiform discharges via template matching under Dynamic Time Warping. J Neurosci Methods 2016; 274:179-190. [PMID: 26944098 PMCID: PMC5519352 DOI: 10.1016/j.jneumeth.2016.02.025] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2016] [Revised: 02/26/2016] [Accepted: 02/29/2016] [Indexed: 10/22/2022]
Abstract
BACKGROUND EEG interpretation relies on experts who are in short supply. There is a great need for automated pattern recognition systems to assist with interpretation. However, attempts to develop such systems have been limited by insufficient expert-annotated data. To address these issues, we developed a system named NeuroBrowser for EEG review and rapid waveform annotation. NEW METHODS At the core of NeuroBrowser lies on ultrafast template matching under Dynamic Time Warping, which substantially accelerates the task of annotation. RESULTS Our results demonstrate that NeuroBrowser can reduce the time required for annotation of interictal epileptiform discharges by EEG experts by 20-90%, with an average of approximately 70%. COMPARISON WITH EXISTING METHOD(S) In comparison with conventional manual EEG annotation, NeuroBrowser is able to save EEG experts approximately 70% on average of the time spent in annotating interictal epileptiform discharges. We have already extracted 19,000+ interictal epileptiform discharges from 100 patient EEG recordings. To our knowledge this represents the largest annotated database of interictal epileptiform discharges in existence. CONCLUSION NeuroBrowser is an integrated system for rapid waveform annotation. While the algorithm is currently tailored to annotation of interictal epileptiform discharges in scalp EEG recordings, the concepts can be easily generalized to other waveforms and signal types.
Collapse
Affiliation(s)
- J Jing
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore.
| | - J Dauwels
- School of Electrical and Electronic Engineering, Nanyang Technological University, Singapore.
| | - T Rakthanmanon
- Department of Computer Engineering, Kasetsart University, Thailand.
| | - E Keogh
- Department of Computer Science and Engineering, University of California, Riverside, CA, USA.
| | - S S Cash
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, MA, USA.
| | - M B Westover
- Department of Neurology, Massachusetts General Hospital, Harvard Medical School, MA, USA.
| |
Collapse
|
18
|
Vollero L, Petrichella S, Innello G. Optimal weighted averaging of event related activity from acquisitions with artifacts. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2016:977-980. [PMID: 28268487 DOI: 10.1109/embc.2016.7590865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
In several biomedical applications that require the signal processing of biological data, the starting procedure for noise reduction is the ensemble averaging of multiple repeated acquisitions (trials). This method is based on the assumption that each trial is composed of two additive components: (i) a time-locked activity related to some sensitive/stimulation phenomenon (ERA, Event Related Activity in the following) and (ii) a sum of several other non time-locked background activities. The averaging aims at estimating the ERA activity under very low Signal to Noise and Interference Ratio (SNIR). Although averaging is a well established tool, its performance can be improved in the presence of high-power disturbances (artifacts) by a trials classification and removal stage. In this paper we propose, model and evaluate a new approach that avoids trials removal, managing trials classified as artifact-free and artifact-prone with two different weights. Based on the model, a weights tuning is possible and through modeling and simulations we show that, when optimally configured, the proposed solution outperforms classical approaches.
Collapse
|
19
|
Hajipour Sardouie S, Shamsollahi M, Albera L, Merlet I. Interictal EEG noise cancellation: GEVD and DSS based approaches versus ICA and DCCA based methods. Ing Rech Biomed 2015. [DOI: 10.1016/j.irbm.2014.10.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
20
|
Shibasaki H, Nakamura M, Sugi T, Nishida S, Nagamine T, Ikeda A. Automatic interpretation and writing report of the adult waking electroencephalogram. Clin Neurophysiol 2014; 125:1081-94. [DOI: 10.1016/j.clinph.2013.12.114] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2013] [Revised: 12/03/2013] [Accepted: 12/17/2013] [Indexed: 11/28/2022]
|
21
|
Lodder SS, van Putten MJAM. A self-adapting system for the automated detection of inter-ictal epileptiform discharges. PLoS One 2014; 9:e85180. [PMID: 24454813 PMCID: PMC3893182 DOI: 10.1371/journal.pone.0085180] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2013] [Accepted: 11/25/2013] [Indexed: 11/18/2022] Open
Abstract
PURPOSE Scalp EEG remains the standard clinical procedure for the diagnosis of epilepsy. Manual detection of inter-ictal epileptiform discharges (IEDs) is slow and cumbersome, and few automated methods are used to assist in practice. This is mostly due to low sensitivities, high false positive rates, or a lack of trust in the automated method. In this study we aim to find a solution that will make computer assisted detection more efficient than conventional methods, while preserving the detection certainty of a manual search. METHODS Our solution consists of two phases. First, a detection phase finds all events similar to epileptiform activity by using a large database of template waveforms. Individual template detections are combined to form "IED nominations", each with a corresponding certainty value based on the reliability of their contributing templates. The second phase uses the ten nominations with highest certainty and presents them to the reviewer one by one for confirmation. Confirmations are used to update certainty values of the remaining nominations, and another iteration is performed where ten nominations with the highest certainty are presented. This continues until the reviewer is satisfied with what has been seen. Reviewer feedback is also used to update template accuracies globally and improve future detections. KEY FINDINGS Using the described method and fifteen evaluation EEGs (241 IEDs), one third of all inter-ictal events were shown after one iteration, half after two iterations, and 74%, 90%, and 95% after 5, 10 and 15 iterations respectively. Reviewing fifteen iterations for the 20-30 min recordings 1 took approximately 5 min. SIGNIFICANCE The proposed method shows a practical approach for combining automated detection with visual searching for inter-ictal epileptiform activity. Further evaluation is needed to verify its clinical feasibility and measure the added value it presents.
Collapse
Affiliation(s)
- Shaun S. Lodder
- Clinical Neurophysiology, MIRA-Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
- * E-mail:
| | - Michel J. A. M. van Putten
- Clinical Neurophysiology, MIRA-Institute for Biomedical Technology and Technical Medicine, University of Twente, Enschede, The Netherlands
- Department of Neurology and Clinical Neurophysiology, Medisch Spectrum Twente, Enschede, The Netherlands
| |
Collapse
|
22
|
Lodder SS, Askamp J, van Putten MJ. Inter-ictal spike detection using a database of smart templates. Clin Neurophysiol 2013; 124:2328-35. [PMID: 23791532 DOI: 10.1016/j.clinph.2013.05.019] [Citation(s) in RCA: 33] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2013] [Revised: 04/11/2013] [Accepted: 05/27/2013] [Indexed: 10/26/2022]
|
23
|
Liu YC, Lin CCK, Tsai JJ, Sun YN. Model-based spike detection of epileptic EEG data. SENSORS 2013; 13:12536-47. [PMID: 24048343 PMCID: PMC3821325 DOI: 10.3390/s130912536] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2013] [Revised: 09/06/2013] [Accepted: 09/13/2013] [Indexed: 11/16/2022]
Abstract
Accurate automatic spike detection is highly beneficial to clinical assessment of epileptic electroencephalogram (EEG) data. In this paper, a new two-stage approach is proposed for epileptic spike detection. First, the k-point nonlinear energy operator (k-NEO) is adopted to detect all possible spike candidates, then a newly proposed spike model with slow wave features is applied to these candidates for spike classification. Experimental results show that the proposed system, using the AdaBoost classifier, outperforms the conventional method in both two- and three-class EEG pattern classification problems. The proposed system not only achieves better accuracy for spike detection, but also provides new ability to differentiate between spikes and spikes with slow waves. Though spikes with slow waves occur frequently in epileptic EEGs, they are not used in conventional spike detection. Identifying spikes with slow waves allows the proposed system to have better capability for assisting clinical neurologists in routine EEG examinations and epileptic diagnosis.
Collapse
Affiliation(s)
- Yung-Chun Liu
- Department of Computer Science and Information Engineering, National Cheng Kung University, No. 1, University Road, Tainan City 701, Taiwan; E-Mail:
- Medical Device Innovation Center, National Cheng Kung University, No. 1, University Road, Tainan City 701, Taiwan
| | - Chou-Ching K. Lin
- Department of Neurology, National Cheng Kung University Hospital, No. 138, Sheng Li Road, Tainan City 704, Taiwan; E-Mails: (C.-C.K.L.); (J.-J.T.)
| | - Jing-Jane Tsai
- Department of Neurology, National Cheng Kung University Hospital, No. 138, Sheng Li Road, Tainan City 704, Taiwan; E-Mails: (C.-C.K.L.); (J.-J.T.)
| | - Yung-Nien Sun
- Department of Computer Science and Information Engineering, National Cheng Kung University, No. 1, University Road, Tainan City 701, Taiwan; E-Mail:
- Medical Device Innovation Center, National Cheng Kung University, No. 1, University Road, Tainan City 701, Taiwan
- Author to whom correspondence should be addressed; E-Mail: ; Tel.: +886-6-275-7575 (ext. 62526); Fax: +886-6-274-7076
| |
Collapse
|
24
|
Shen CP, Liu ST, Zhou WZ, Lin FS, Lam AYY, Sung HY, Chen W, Lin JW, Chiu MJ, Pan MK, Kao JH, Wu JM, Lai F. A physiology-based seizure detection system for multichannel EEG. PLoS One 2013; 8:e65862. [PMID: 23799053 PMCID: PMC3683026 DOI: 10.1371/journal.pone.0065862] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2012] [Accepted: 04/29/2013] [Indexed: 11/22/2022] Open
Abstract
Background Epilepsy is a common chronic neurological disorder characterized by recurrent unprovoked seizures. Electroencephalogram (EEG) signals play a critical role in the diagnosis of epilepsy. Multichannel EEGs contain more information than do single-channel EEGs. Automatic detection algorithms for spikes or seizures have traditionally been implemented on single-channel EEG, and algorithms for multichannel EEG are unavailable. Methodology This study proposes a physiology-based detection system for epileptic seizures that uses multichannel EEG signals. The proposed technique was tested on two EEG data sets acquired from 18 patients. Both unipolar and bipolar EEG signals were analyzed. We employed sample entropy (SampEn), statistical values, and concepts used in clinical neurophysiology (e.g., phase reversals and potential fields of a bipolar EEG) to extract the features. We further tested the performance of a genetic algorithm cascaded with a support vector machine and post-classification spike matching. Principal Findings We obtained 86.69% spike detection and 99.77% seizure detection for Data Set I. The detection system was further validated using the model trained by Data Set I on Data Set II. The system again showed high performance, with 91.18% detection of spikes and 99.22% seizure detection. Conclusion We report a de novo EEG classification system for seizure and spike detection on multichannel EEG that includes physiology-based knowledge to enhance the performance of this type of system.
Collapse
Affiliation(s)
- Chia-Ping Shen
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Shih-Ting Liu
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Wei-Zhi Zhou
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Feng-Seng Lin
- Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
| | - Andy Yan-Yu Lam
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Hsiao-Ya Sung
- Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
| | - Wei Chen
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Jeng-Wei Lin
- Department of Information Management, Tunghai University, Tai-Chung, Taiwan
| | - Ming-Jang Chiu
- Department of Neurology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
- Graduate Institute of Brain and Mind Sciences, National Taiwan University, Taipei, Taiwan
- Department of Psychology, College of Science, National Taiwan University, Taipei, Taiwan
- * E-mail:
| | - Ming-Kai Pan
- Department of Neurology, National Taiwan University Hospital, College of Medicine, National Taiwan University, Taipei, Taiwan
- Graduate Institute of Brain and Mind Sciences, National Taiwan University, Taipei, Taiwan
- Department of Psychology, College of Science, National Taiwan University, Taipei, Taiwan
| | - Jui-Hung Kao
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Jin-Ming Wu
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
| | - Feipei Lai
- Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan
- Department of Computer Science and Information Engineering, National Taiwan University, Taipei, Taiwan
| |
Collapse
|
25
|
Nonclercq A, Foulon M, Verheulpen D, De Cock C, Buzatu M, Mathys P, Van Bogaert P. Cluster-based spike detection algorithm adapts to interpatient and intrapatient variation in spike morphology. J Neurosci Methods 2012; 210:259-65. [PMID: 22850558 DOI: 10.1016/j.jneumeth.2012.07.015] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2012] [Revised: 07/09/2012] [Accepted: 07/23/2012] [Indexed: 10/28/2022]
|
26
|
Tan KK, Tang KZ, Putra AS, Pu X, Huang S, Lee TH, Ng SC, Tan LG. An auto-perfusing umbilical cord blood collection instrument. ISA TRANSACTIONS 2012; 51:420-429. [PMID: 22342030 DOI: 10.1016/j.isatra.2012.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2011] [Revised: 12/30/2011] [Accepted: 01/03/2012] [Indexed: 05/31/2023]
Abstract
In this paper, the development of an automated umbilical cord blood (UCB) collection instrument, comprising of mechanical, electronics and control components, is provided in detail. UCB from the placenta provides a rich source of highly proliferative cells for many clinical uses as it contains rich Hematopoietic Stem Cells (HSCs) which yield many benefits over traditional sources such as the bone marrow and periphery blood. Current collection of UCB uses a syringe to extract blood from placenta, which is highly limited in volume and cell numbers. This paper will present the development of an automated UCB collection instrument to yield improved performance which comprised four subsystems. First, a placenta handling system is designed to produce air pressure which can realize the emulation of the uterus compression on the placenta. Second, an auto-medium injector system is presented to enable perfusion automatically. Third, a time window widening system is developed which generates vibrations during the perfusion phase and helps the exposed end of the cord cool down to a low temperature. Finally, a control platform is used to integrate all systems working together, hosting the control algorithms which operate the instrument automatically.
Collapse
Affiliation(s)
- K K Tan
- Department of Electrical & Computer Engineering, National University of Singapore, Singapore.
| | | | | | | | | | | | | | | |
Collapse
|