1
|
Jenkins C, Kiourti A. Characterizing the dispersion behavior of poly-atomic magnetic metamaterials. Sci Rep 2024; 14:16334. [PMID: 39009711 PMCID: PMC11251064 DOI: 10.1038/s41598-024-67248-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 07/09/2024] [Indexed: 07/17/2024] Open
Abstract
The propagation of magnetoinductive (MI) waves across magnetic metamaterials known as magnetoinductive waveguides (MIWs) has been an area of interest for many applications due to the flexible design and low-loss performance in challenging radio-frequency (RF) environments. Thus far, the dispersion behavior of MIWs has been limited to mono- and diatomic geometries. In this work, we present a recursive method to generate the dispersion equation for a general poly-atomic MIW. This recursive method greatly simplifies the ability to create closed-form dispersion equations for unique poly-atomic MIW geometries versus the previous method. To demonstrate, four MIW geometries that have been selected for their unique symmetries are analyzed using the recursive method. Using applicable simplifications brought on by the geometric symmetries, a closed-form dispersion equation is reported for each case. The equations are then validated numerically and show excellent agreement in all four cases. This work simultaneously aids in the further development of MIW theory and offers new avenues for MIW design in the presented dispersion equations.
Collapse
Affiliation(s)
- Connor Jenkins
- ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, 43212, USA.
| | - Asimina Kiourti
- ElectroScience Laboratory, Department of Electrical and Computer Engineering, The Ohio State University, Columbus, OH, 43212, USA
| |
Collapse
|
2
|
Syms RRA, Wadsworth CA, Kardoulaki E, Titapun A, Boonphongsathien W, Sa-Ngiamwibool P, Zhang S, Taylor-Robinson SD, Chamadol N, Loilome W. Intraductal magnetic resonance imaging of cholangiocarcinoma - a practical possibility. Front Oncol 2024; 14:1306242. [PMID: 38651146 PMCID: PMC11033360 DOI: 10.3389/fonc.2024.1306242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Accepted: 03/26/2024] [Indexed: 04/25/2024] Open
Abstract
Intraductal T2 mapping based on a catheter receiver is proposed as a method of visualizing the extent of intraductal and periductal cholangiocarcinoma (CCA). Compared to external receivers, internal receivers provide locally enhanced signal-to-noise ratios by virtue of their lower field-of-view for body noise, allowing smaller voxels and higher resolution. However, inherent radial sensitivity variation and segmentation for patient safety both distort image brightness. We discuss simulated T2 weighted images and T2 maps, and in vitro images obtained using a thin film catheter receiver of a freshly resected liver specimen containing a polypoid intraductal tumor from a patient with CCA. T2 mapping provides a simple method of compensating non-uniform signal reception patterns of catheter receivers, allowing the visualization of tumor extent without contrast enhancement and potentially quantitative tissue characterization. Potential advantages and disadvantages of in vivo intraductal imaging are considered.
Collapse
Affiliation(s)
- Richard R. A. Syms
- Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
| | - Christopher A. Wadsworth
- Department of Surgery and Cancer at St Mary’s Hospital, Imperial College London, London, United Kingdom
| | - Evdokia Kardoulaki
- Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
| | - Attapol Titapun
- Department of Surgery, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| | | | | | - Shuo Zhang
- Health Systems, Clinical Science, Philips Healthcare Germany, Hamburg, Germany
| | - Simon D. Taylor-Robinson
- Department of Electrical and Electronic Engineering, Imperial College London, London, United Kingdom
- Department of Surgery and Cancer at St Mary’s Hospital, Imperial College London, London, United Kingdom
| | - Nittaya Chamadol
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| | - Watcharin Loilome
- Cholangiocarcinoma Research Institute, Faculty of Medicine, Khon Kaen University, Khon Kaen, Thailand
| |
Collapse
|
3
|
Chamadol N, Syms R, Laopaiboon V, Promsorn J, Eurboonyanun K. New Imaging Techniques. Recent Results Cancer Res 2023; 219:109-145. [PMID: 37660333 DOI: 10.1007/978-3-031-35166-2_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/05/2023]
Abstract
The chapter discusses the advancement of new imaging techniques, the role of imaging in CCA diagnosis, anatomical and morphological classification, ultrasound screening of CCA, ultrasound findings of MF-CCA, PI-CCA, ID-CCA, the use of CT in CCA diagnosis, staging and treatment planning, CT volumetry and estimation of future liver remnant, post-treatment follow-up and surveillance, MRI imaging, Positron Emission Tomography (PET)/CT, limitations to contrast studies and resolution, internal receivers for CCA imaging, and in vitro imaging of CCA.
Collapse
Affiliation(s)
- Nittaya Chamadol
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand.
| | - Richard Syms
- Department of Electrical and Electronic Engineering, Imperial College London, Exhibition Road, London, SW7 2AZ, UK
| | - Vallop Laopaiboon
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Julaluck Promsorn
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Kulyada Eurboonyanun
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand
| |
Collapse
|
4
|
Khuntikeo N, Titapun A, Chamadol N, Boonphongsathien W, Sa-Ngiamwibool P, Taylor-Robinson SD, Wadsworth CA, Zhang S, Kardoulaki EM, Syms RRA. In Vitro Intraductal MRI and T2 Mapping of Cholangiocarcinoma Using Catheter Coils. Hepat Med 2020; 12:107-114. [PMID: 32801954 PMCID: PMC7397475 DOI: 10.2147/hmer.s266841] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 07/09/2020] [Indexed: 01/03/2023] Open
Abstract
AIM Diagnostic imaging of early-stage cholangiocarcinoma is challenging. A previous in vitro study of fixed-tissue liver resection specimens investigated T2 mapping as a method of exploiting the locally increased signal-to-noise ratio (SNR) of duodenoscope coils for improved quantitative magnetic resonance imaging (MRI), despite their non-uniform sensitivity. This work applies similar methods to unfixed liver specimens using catheter-based receivers. METHODS Ex vivo intraductal MRI and T2 mapping were carried out at 3T on unfixed resection specimens obtained from cholangiocarcinoma patients immediately after surgery using a catheter coil based on a thin-film magneto-inductive waveguide, inserted directly into an intrahepatic duct. RESULTS Polypoid intraductal cholangiocarcinoma was imaged using fast spin-echo sequences. High-resolution T2 maps were extracted by fitting of data obtained at different echo times to mono-exponential models, and disease-induced changes were correlated with histopathology. An increase in T2 was found compared with fixed specimens and differences in T2 allowed the resolution of tumour tissue and malignant features such as polypoid morphology. CONCLUSION Despite their limited field of view, useful data can be obtained using catheter coils, and T2 mapping offers an effective method of exploiting their local SNR advantage without the need for image correction.
Collapse
Affiliation(s)
- Narong Khuntikeo
- Department. of Surgery, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Attapol Titapun
- Department. of Surgery, Faculty of Medicine, Khon Kaen University, Khon Kaen, 40002, Thailand
| | - Nittaya Chamadol
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen40002, Thailand
| | | | - Prakasit Sa-Ngiamwibool
- Department of Pathology, Faculty of Medicine, Khon Kaen University, Khon Kaen40002, Thailand
| | | | | | - Shuo Zhang
- Philips Healthcare Germany, Health Systems, Clinical Science, Hamburg, Germany
| | | | | |
Collapse
|
5
|
Khuntikeo N, Titapun A, Chamadol N, Boonphongsathien W, Sa-Ngiamwibool P, Taylor-Robinson SD, Wadsworth CA, Zhang S, Kardoulaki EM, Young IR, Syms RRA. Improving the Detection of Cholangiocarcinoma: In vitro MRI-Based Study Using Local Coils and T2 Mapping. Hepat Med 2020; 12:29-39. [PMID: 32280284 PMCID: PMC7127873 DOI: 10.2147/hmer.s232392] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/25/2019] [Accepted: 02/20/2020] [Indexed: 12/15/2022] Open
Abstract
Aim Cholangiocarcinoma is endemic in southeast Asia, generally developing from liver fluke infestation. However, diagnostic imaging of early-stage disease is challenging. The aim of this work is to investigate relaxometry (specifically, T2 mapping) as a method of exploiting the higher signal-to-noise ratio (SNR) of internal coils for improved reception of magnetic resonance signals, despite their non-uniform sensitivity. Methods Ex vivo T2 mapping was carried out at 3T on fixed resection specimens from Thai cholangiocarcinoma patients using an mGRASE sequence and an endoscope coil based on a thin-film magneto-inductive waveguide and designed ultimately for internal use. Results Disease-induced changes including granulomatous inflammation, intraepithelial neoplasia and intraductal tumours were correlated with histopathology, and relaxation data were compared with mono- and bi-exponential models of T2 relaxation. An approximately 10-fold local advantage in SNR compared to a 16-element torso coil was demonstrated using the endoscope coil, and improved tissue differentiation was obtained without contrast agents. Conclusion The performance advantage above follows directly from the inverse relation between the component of the standard deviation of T2 due to thermal noise and the SNR, and offers an effective method of exploiting the SNR advantage of internal coils. No correction is required, avoiding the need for tracking, relaxing constraints on coil and slice orientation and providing rapid visualization.
Collapse
Affiliation(s)
- Narong Khuntikeo
- Department of Surgery, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Attapol Titapun
- Department of Surgery, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Nittaya Chamadol
- Department of Radiology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
| | | | - Prakasit Sa-Ngiamwibool
- Department of Pathology, Faculty of Medicine, Khon Kaen University, Khon Kaen 40002, Thailand
| | - Simon D Taylor-Robinson
- Division of Surgery and Cancer, Imperial College London, Liver Unit, St. Mary's Hospital, London W2 1NY, UK
| | - Christopher A Wadsworth
- Division of Surgery and Cancer, Imperial College London, Liver Unit, St. Mary's Hospital, London W2 1NY, UK
| | - Shuo Zhang
- Philips Healthcare Germany, Health Systems, Clinical Science, Hamburg 22335, Germany
| | | | - Ian R Young
- EEE Department, Imperial College, London SW7 2AZ, UK
| | | |
Collapse
|
6
|
Alipour A, Meyer ES, Dumoulin CL, Watkins RD, Elahi H, Loew W, Schweitzer J, Olson G, Chen Y, Tao S, Guttman M, Kolandaivelu A, Halperin HR, Schmidt EJ. MRI Conditional Actively Tracked Metallic Electrophysiology Catheters and Guidewires With Miniature Tethered Radio-Frequency Traps: Theory, Design, and Validation. IEEE Trans Biomed Eng 2019; 67:1616-1627. [PMID: 31535979 DOI: 10.1109/tbme.2019.2941460] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVE Cardiovascular interventional devices typically have long metallic braids or backbones to aid in steerability and pushability. However, electromagnetic coupling of metallic-based cardiovascular interventional devices with the radiofrequency (RF) fields present during Magnetic Resonance Imaging (MRI) can make a device unsafe for use in an MRI scanner. We aimed to develop MRI conditional actively-tracked cardiovascular interventional devices by sufficiently attenuating induced currents on the metallic braid/tube and internal-cabling using miniaturized resonant floating RF traps (MBaluns). METHOD MBaluns were designed for placement at multiple locations along a conducting cardiovascular device to prevent the establishment of standing waves and to dissipate RF-induced energy. The MBaluns were constructed with loosely-wound solenoids to be sensitive to transverse magnetic fields created by both surface currents on the device's metallic backbone and common-mode currents on internal cables. Electromagnetic simulations were used to optimize MBalun parameters. Following optimization, two different MBalun designs were applied to MR-actively-tracked metallic guidewires and metallic-braided electrophysiology ablation catheters. Control-devices were constructed without MBaluns. MBalun performance was validated using network-analyzer quantification of current attenuation, electromagnetic Specific-Absorption-Rate (SAR) analysis, thermal tests during high SAR pulse sequences, and MRI-guided cardiovascular navigation in swine. RESULTS Electromagnetic SAR simulations resulted in ≈20 dB attenuation at the tip of the wire using six successive MBaluns. Network-analyzer tests confirmed ∼17 dB/MBalun surface-current attenuation. Thermal tests indicated temperature decreases of 5.9 °C in the MBalun-equipped guidewire tip. Both devices allowed rapid vascular navigation resulting from good torquability and MR-Tracking visibility. CONCLUSION MBaluns increased device diameter by 20%, relative to conventional devices, providing a spatially-efficient means to prevent heating during MRI. SIGNIFICANCE MBaluns allow use of long metallic components, which improves mechanical performance in active MR-guided interventional devices.
Collapse
|