1
|
Zhang L, Chen J, Ma C, Liu X, Xu L. Performance Analysis of Electromyogram Signal Compression Sampling in a Wireless Body Area Network. MICROMACHINES 2022; 13:1748. [PMID: 36296102 PMCID: PMC9611018 DOI: 10.3390/mi13101748] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2022] [Revised: 10/10/2022] [Accepted: 10/13/2022] [Indexed: 06/16/2023]
Abstract
The rapid growth in demand for portable and intelligent hardware has caused tremendous pressure on signal sampling, transfer, and storage resources. As an emerging signal acquisition technology, compressed sensing (CS) has promising application prospects in low-cost wireless sensor networks. To achieve reduced energy consumption and maintain a longer acquisition duration for high sample rate electromyogram (EMG) signals, this paper comprehensively analyzes the compressed sensing method using EMG. A fair comparison is carried out on the performances of 52 ordinary wavelet sparse bases and five widely applied reconstruction algorithms at different compression levels. The experimental results show that the db2 wavelet basis can sparse EMG signals so that the compressed EMG signals are reconstructed properly, thanks to its low percentage root mean square distortion (PRD) values at most compression ratios. In addition, the basis pursuit (BP) reconstruction algorithm can provide a more efficient reconstruction process and better reconstruction performance by comparison. The experiment records and comparative analysis screen out the suitable sparse bases and reconstruction algorithms for EMG signals, acting as prior experiments for further practical applications and also a benchmark for future academic research.
Collapse
Affiliation(s)
- Liangyu Zhang
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110169, China
| | - Junxin Chen
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110169, China
| | - Chenfei Ma
- Edinburgh Neuroprosthetics Laboratory, School of Informatics, The University of Edinburgh, 10 Crichton Street, Edinburgh EH8 9AB, UK
| | - Xiufang Liu
- Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, China
| | - Lisheng Xu
- College of Medicine and Biological Information Engineering, Northeastern University, 195 Innovation Road, Shenyang 110169, China
| |
Collapse
|
2
|
Goergen CJ, Tweardy MJ, Steinhubl SR, Wegerich SW, Singh K, Mieloszyk RJ, Dunn J. Detection and Monitoring of Viral Infections via Wearable Devices and Biometric Data. Annu Rev Biomed Eng 2022; 24:1-27. [PMID: 34932906 PMCID: PMC9218991 DOI: 10.1146/annurev-bioeng-103020-040136] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Mounting clinical evidence suggests that viral infections can lead to detectable changes in an individual's normal physiologic and behavioral metrics, including heart and respiration rates, heart rate variability, temperature, activity, and sleep prior to symptom onset, potentially even in asymptomatic individuals. While the ability of wearable devices to detect viral infections in a real-world setting has yet to be proven, multiple recent studies have established that individual, continuous data from a range of biometric monitoring technologies can be easily acquired and that through the use of machine learning techniques, physiological signals and warning signs can be identified. In this review, we highlight the existing knowledge base supporting the potential for widespread implementation of biometric data to address existing gaps in the diagnosis and treatment of viral illnesses, with a particular focus on the many important lessons learned from the coronavirus disease 2019 pandemic.
Collapse
Affiliation(s)
- Craig J Goergen
- Weldon School of Biomedical Engineering, Purdue University, West Lafayette, Indiana, USA;
| | | | - Steven R Steinhubl
- physIQ Inc., Chicago, Illinois, USA
- Scripps Research Translational Institute, La Jolla, California, USA
| | | | - Karnika Singh
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| | | | - Jessilyn Dunn
- Department of Biomedical Engineering, Duke University, Durham, North Carolina, USA
| |
Collapse
|
3
|
Pope GC, Halter RJ. Design and Implementation of an Ultra-Low Resource Electrodermal Activity Sensor for Wearable Applications ‡. SENSORS 2019; 19:s19112450. [PMID: 31146358 PMCID: PMC6603545 DOI: 10.3390/s19112450] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2019] [Revised: 05/11/2019] [Accepted: 05/17/2019] [Indexed: 02/05/2023]
Abstract
While modern low-power microcontrollers are a cornerstone of wearable physiological sensors, their limited on-chip storage typically makes peripheral storage devices a requirement for long-term physiological sensing—significantly increasing both size and power consumption. Here, a wearable biosensor system capable of long-term recording of physiological signals using a single, 64 kB microcontroller to minimize sensor size and improve energy performance is described. Electrodermal (EDA) signals were sampled and compressed using a multiresolution wavelet transformation to achieve long-term storage within the limited memory of a 16-bit microcontroller. The distortion of the compressed signal and errors in extracting common EDA features is evaluated across 253 independent EDA signals acquired from human volunteers. At a compression ratio (CR) of 23.3×, the root mean square error (RMSErr) is below 0.016 μS and the percent root-mean-square difference (PRD) is below 1%. Tonic EDA features are preserved at a CR = 23.3× while phasic EDA features are more prone to reconstruction errors at CRs > 8.8×. This compression method is shown to be competitive with other compressive sensing-based approaches for EDA measurement while enabling on-board access to raw EDA data and efficient signal reconstructions. The system and compression method provided improves the functionality of low-resource microcontrollers by limiting the need for external memory devices and wireless connectivity to advance the miniaturization of wearable biosensors for mobile applications.
Collapse
Affiliation(s)
- Gunnar C Pope
- Thayer School of Engineering at Dartmouth, Dartmouth College, Hanover, NH 03755, USA.
| | - Ryan J Halter
- Thayer School of Engineering at Dartmouth, Dartmouth College, Hanover, NH 03755, USA.
| |
Collapse
|
4
|
Alvarez GDY, Favaro F, Lecumberry F, Martin A, Oliver JP, Oreggioni J, Ramirez I, Seroussi G, Steinfeld L. Wireless EEG System Achieving High Throughput and Reduced Energy Consumption Through Lossless and Near-Lossless Compression. IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS 2018; 12:231-241. [PMID: 29377811 DOI: 10.1109/tbcas.2017.2779324] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
This work presents a wireless multichannel electroencephalogram (EEG) recording system featuring lossless and near-lossless compression of the digitized EEG signal. Two novel, low-complexity, efficient compression algorithms were developed and tested in a low-power platform. The algorithms were tested on six public EEG databases comparing favorably with the best compression rates reported up to date in the literature. In its lossless mode, the platform is capable of encoding and transmitting 59-channel EEG signals, sampled at 500 Hz and 16 bits per sample, at a current consumption of 337 A per channel; this comes with a guarantee that the decompressed signal is identical to the sampled one. The near-lossless mode allows for significant energy savings and/or higher throughputs in exchange for a small guaranteed maximum per-sample distortion in the recovered signal. Finally, we address the tradeoff between computation cost and transmission savings by evaluating three alternatives: sending raw data, or encoding with one of two compression algorithms that differ in complexity and compression performance. We observe that the higher the throughput (number of channels and sampling rate) the larger the benefits obtained from compression.
Collapse
|
5
|
Batchelor JC, Casson AJ. Inkjet printed ECG electrodes for long term biosignal monitoring in personalized and ubiquitous healthcare. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2016; 2015:4013-6. [PMID: 26737174 DOI: 10.1109/embc.2015.7319274] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This paper investigates the performance of inkjet printed electrodes for electrocardiogram (ECG) monitoring in personalized and ubiquitous healthcare. As a rapid prototyping, additive manufacturing approach, inkjet printing can allow personalization of electrode sizes and shapes and can be used with a range of substrates to achieve good long term connections to the skin. We compare the performance of two types of inkjet electrodes printed using different substrates. Results demonstrate that both new electrodes can record ECG information, with comparable signal-to-noise ratios to conventional Ag/AgCl electrodes. The time-frequency decomposition of the collected signals is also explored.
Collapse
|
6
|
Wang C, Lu W, Narayanan MR, Redmond SJ, Lovell NH. Low-power technologies for wearable telecare and telehealth systems: A review. Biomed Eng Lett 2015. [DOI: 10.1007/s13534-015-0174-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023] Open
|
7
|
Misra S, Chatterjee S. Social choice considerations in cloud-assisted WBAN architecture for post-disaster healthcare: Data aggregation and channelization. Inf Sci (N Y) 2014. [DOI: 10.1016/j.ins.2014.05.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
8
|
Gharghan SK, Nordin R, Ismail M. Energy-efficient ZigBee-based wireless sensor network for track bicycle performance monitoring. SENSORS 2014; 14:15573-92. [PMID: 25153141 PMCID: PMC4179082 DOI: 10.3390/s140815573] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/12/2014] [Revised: 08/11/2014] [Accepted: 08/13/2014] [Indexed: 11/16/2022]
Abstract
In a wireless sensor network (WSN), saving power is a vital requirement. In this paper, a simple point-to-point bike WSN was considered. The data of bike parameters, speed and cadence, were monitored and transmitted via a wireless communication based on the ZigBee protocol. Since the bike parameters are monitored and transmitted on every bike wheel rotation, this means the sensor node does not sleep for a long time, causing power consumption to rise. Therefore, a newly proposed algorithm, known as the Redundancy and Converged Data (RCD) algorithm, was implemented for this application to put the sensor node into sleep mode while maintaining the performance measurements. This is achieved by minimizing the data packets transmitted as much as possible and fusing the data of speed and cadence by utilizing the correlation measurements between them to minimize the number of sensor nodes in the network to one node, which results in reduced power consumption, cost, and size, in addition to simpler hardware implementation. Execution of the proposed RCD algorithm shows that this approach can reduce the current consumption to 1.69 mA, and save 95% of the sensor node energy. Also, the comparison results with different wireless standard technologies demonstrate minimal current consumption in the sensor node.
Collapse
Affiliation(s)
- Sadik K Gharghan
- Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM Bangi, 43600 Selangor, Malaysia.
| | - Rosdiadee Nordin
- Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM Bangi, 43600 Selangor, Malaysia.
| | - Mahamod Ismail
- Department of Electrical, Electronic and System Engineering, Faculty of Engineering and Built Environment, Universiti Kebangsaan Malaysia, UKM Bangi, 43600 Selangor, Malaysia.
| |
Collapse
|
9
|
Imtiaz SA, Logesparan L, Rodriguez-Villegas E. Performance-power consumption tradeoff in wearable epilepsy monitoring systems. IEEE J Biomed Health Inform 2014; 19:1019-1028. [PMID: 25069131 DOI: 10.1109/jbhi.2014.2342501] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Automated seizure detection methods can be used to reduce time and costs associated with analyzing large volumes of ambulatory EEG recordings. These methods however have to rely on very complex, power hungry algorithms, implemented on the system backend, in order to achieve acceptable levels of accuracy. In size, and therefore power-constrained EEG systems, an alternative approach to the problem of data reduction is online data selection, in which simpler algorithms select potential epileptiform activity for discontinuous recording but accurate analysis is still left to a medical practitioner. Such a diagnostic decision support system would still provide doctors with information relevant for diagnosis while reducing the time taken to analyze the EEG. For wearable systems with limited power budgets, data selection algorithm must be of sufficiently low complexity in order to reduce the amount of data transmitted and the overall power consumption. In this paper, we present a low-power hardware implementation of an online epileptic seizure data selection algorithm with encryption and data transmission and demonstrate the tradeoffs between its accuracy and the overall system power consumption. We demonstrate that overall power savings by data selection can be achieved by transmitting less than 40% of the data. We also show a 29% power reduction when selecting and transmitting 94% of all seizure events and only 10% of background EEG.
Collapse
Affiliation(s)
- Syed Anas Imtiaz
- Department of Electrical and Electronic Engineering, Imperial College London, London, U.K
| | | | | |
Collapse
|