1
|
Payne K, Zhao Y, Bhosale AA, Zhang X. Design of Multichannel Two-row Quadrature Transceive Array for Ultrahigh field MR Imaging. PROCEEDINGS OF THE INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE ... SCIENTIFIC MEETING AND EXHIBITION. INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE. SCIENTIFIC MEETING AND EXHIBITION 2024; 32:1443. [PMID: 38798755 PMCID: PMC11125413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Grants] [Subscribe] [Scholar Register] [Indexed: 05/29/2024]
Affiliation(s)
- Komlan Payne
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States
| | - Yunkun Zhao
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States
| | - Aditya Ashok Bhosale
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States
| | - Xiaoliang Zhang
- Department of Biomedical Engineering, State University of New York at Buffalo, Buffalo, NY, United States
| |
Collapse
|
2
|
Choi CH, Webb A, Orzada S, Kelenjeridze M, Shah NJ, Felder J. A Review of Parallel Transmit Arrays for Ultra-High Field MR Imaging. IEEE Rev Biomed Eng 2024; 17:351-368. [PMID: 37022919 DOI: 10.1109/rbme.2023.3244132] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/12/2023]
Abstract
Parallel transmission (pTX) techniques are required to tackle a number of challenges, e.g., the inhomogeneous distribution of the transmit field and elevated specific absorption rate (SAR), in ultra-high field (UHF) MR imaging. Additionally, they offer multiple degrees of freedom to create temporally- and spatially-tailored transverse magnetization. Given the increasing availability of MRI systems at 7 T and above, it is anticipated that interest in pTX applications will grow accordingly. One of the key components in MR systems capable of pTX is the design of the transmit array, as this has a major impact on performance in terms of power requirements, SAR and RF pulse design. While several reviews on pTX pulse design and the clinical applicability of UHF exist, there is currently no systematic review of pTX transmit/transceiver coils and their associated performance. In this article, we analyze transmit array concepts to determine the strengths and weaknesses of different types of design. We systematically review the different types of individual antennas employed for UHF, their combination into pTX arrays, and methods to decouple the individual elements. We also reiterate figures-of-merit (FoMs) frequently employed to describe the performance of pTX arrays and summarize published array designs in terms of these FoMs.
Collapse
|
3
|
Lu M, Zhang X, Chai S, Yan X. Improving Specific Absorption Rate Efficiency and Coil Robustness of Self-Decoupled Transmit/Receive Coils by Elevating Feed and Mode Conductors. SENSORS (BASEL, SWITZERLAND) 2023; 23:1800. [PMID: 36850397 PMCID: PMC9960379 DOI: 10.3390/s23041800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/12/2023] [Revised: 02/01/2023] [Accepted: 02/03/2023] [Indexed: 06/18/2023]
Abstract
Self-decoupling technology was recently proposed for radio frequency (RF) coil array designs. Here, we propose a novel geometry to reduce the peak local specific absorption rate (SAR) and improve the robustness of the self-decoupled coil. We first demonstrate that B1 is determined by the arm conductors, while the maximum E-field and local SAR are determined by the feed conductor in a self-decoupled coil. Then, we investigate how the B1, E-field, local SAR, SAR efficiency, and coil robustness change with respect to different lift-off distances for feed and mode conductors. Next, the simulation of self-decoupled coils with optimal lift-off distances on a realistic human body is performed. Finally, self-decoupled coils with optimal lift-off distances are fabricated and tested on the workbench and MRI experiments. The peak 10 g-averaged SAR of the self-decoupled coil on the human body can be reduced by 34% by elevating the feed conductor. Less coil mismatching and less resonant frequency shift with respect to loadings were observed by elevating the mode conductor. Both the simulation and experimental results show that the coils with elevated conductors can preserve the high interelement isolation, B1+ efficiency, and SNR of the original self-decoupled coils.
Collapse
Affiliation(s)
- Ming Lu
- College of Nuclear Equipment and Nuclear Engineering, Yantai University, Yantai 264005, China
| | - Xiaoyang Zhang
- College of Nuclear Equipment and Nuclear Engineering, Yantai University, Yantai 264005, China
| | - Shuyang Chai
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Xinqiang Yan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University Medical Center, Nashville, TN 37232, USA
- Department of Electrical and Computer Engineering, Vanderbilt University, Nashville, TN 37232, USA
| |
Collapse
|
4
|
Lu M, Sengupta S, Gore JC, Grissom WA, Yan X. High-Density MRI RF Arrays Using Mixed Dipole Antennas and Microstrip Transmission Line Resonators. IEEE Trans Biomed Eng 2022; 69:3243-3252. [PMID: 35404807 PMCID: PMC9587496 DOI: 10.1109/tbme.2022.3166279] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE High-density multi-coil arrays are desirable in MRI because they provide high signal-to-noise ratios (SNR), enable highly accelerated parallel imaging, and provide more uniform transmit fields at high fields. For high-density arrays such as a head array with 16 elements in a row, popular dipole antennas and microstrip transmission line (also referred to as "MTL") resonators both have severe coupling issues. METHODS In this work, we show that dipoles and MTLs have naturally low coupling and propose a novel array configuration in which they are interleaved. We first show the electromagnetic (EM) coupling between a single dipole and a single MTL across different separations in bench tests. Then we validate and analyze this through EM simulations. Finally, we construct a 16-channel mixed dipole and MTL array and evaluate its performance on the bench and through MRI experiments. RESULTS Without any decoupling treatments, the worst coupling between a dipole and an MTL was only -15.8 dB when their center-to-center distance was 4.7 cm (versus -5.4 dB for two dipole antennas and -6.0 dB for two MTL resonators). Even in a dense 16-channel mixed array, the inter-element isolation among all elements was better than -14 dB. CONCLUSION This study reveals, analyzes, and validates a novel finding that the popular dipole antennas and MTL resonators used in ultrahigh field MRI have naturally low coupling. SIGNIFICANCE These findings will simplify the construction of high-density arrays, enable new applications, and benefit imaging performance in ultrahigh field MRI.
Collapse
|
5
|
Payne K, Zhang X. Hairpin Radio Frequency Coil Array with High Inter-channel isolation for 7T Magnetic Resonance Imaging. PROCEEDINGS OF THE INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE ... SCIENTIFIC MEETING AND EXHIBITION. INTERNATIONAL SOCIETY FOR MAGNETIC RESONANCE IN MEDICINE. SCIENTIFIC MEETING AND EXHIBITION 2022; 30:4503. [PMID: 36071699 PMCID: PMC9445059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Grants] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Affiliation(s)
- Komlan Payne
- Jacobs School of Medicine & Biomedical Sciences, University at Buffalo, The State University of New York, Buffalo, NY, United States
| | - Xiaoliang Zhang
- Jacobs School of Medicine & Biomedical Sciences, University at Buffalo, The State University of New York, Buffalo, NY, United States
| |
Collapse
|
6
|
Kazemivalipour E, Sadeghi-Tarakameh A, Atalar E. Eigenmode analysis of the scattering matrix for the design of MRI transmit array coils. Magn Reson Med 2020; 85:1727-1741. [PMID: 33034125 DOI: 10.1002/mrm.28533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2020] [Revised: 09/03/2020] [Accepted: 09/04/2020] [Indexed: 02/02/2023]
Abstract
PURPOSE To obtain efficient operation modes of transmit array (TxArray) coils using a general design technique based on the eigenmode analysis of the scattering matrix. METHODS We introduce the concept of modal reflected power and excitation eigenmodes, which are calculated as the eigenvalues and eigenvectors of SH S, where the superscript H denotes the Hermitian transpose. We formulate the normalized reflected power, which is the ratio of the total reflected power to the total incident power of TxArray coils for a given excitation signal as the weighted sum of the modal reflected power. By minimizing the modal reflected power of TxArray coils, we increase the excitation space with a low total reflection. The algorithm was tested on 4 dual-row TxArray coils with 8 to 32 channels. RESULTS By minimizing the modal reflected power, we designed an 8-element TxArray coil to have a low reflection for 7 out of 8 dimensions of the excitation space. Similarly, the minimization of the modal reflected power of a 16-element TxArray coil enabled us to enlarge the dimension of the excitation space by 50% compared with commonly employed design techniques. Moreover, we demonstrated that the low total reflected power for some critical excitation modes, such as the circularly polarized mode, can be achieved for all TxArray coils even with a high level of coupling. CONCLUSION Eigenmode analysis is an efficient method that intuitively provides a quantitative and compact representation of the coil's power transmission capabilities. This method also provides insight into the excitation modes with low reflection.
Collapse
Affiliation(s)
- Ehsan Kazemivalipour
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Alireza Sadeghi-Tarakameh
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| | - Ergin Atalar
- Department of Electrical and Electronics Engineering, Bilkent University, Ankara, Turkey.,National Magnetic Resonance Research Center (UMRAM), Bilkent University, Ankara, Turkey
| |
Collapse
|
7
|
Maunder A, Rao M, Robb F, Wild JM. An 8-element Tx/Rx array utilizing MEMS detuning combined with 6 Rx loops for 19 F and 1 H lung imaging at 1.5T. Magn Reson Med 2020; 84:2262-2277. [PMID: 32281139 DOI: 10.1002/mrm.28260] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2019] [Revised: 02/27/2020] [Accepted: 02/27/2020] [Indexed: 12/24/2022]
Abstract
PURPOSE To firstly improve the attainable image SNR of 19 F and 1 H C3 F8 lung imaging at 1.5 tesla using an 8-element transmit/receive (Tx/Rx) flexible vest array combined with a 6-element Rx-only array, and to secondly evaluate microelectromechanical systems for switching the array elements between the 2 resonant frequencies. METHODS The Tx efficiency and homogeneity of the 8-element array were measured and simulated for 1 H imaging in a cylindrical phantom and then evaluated for in vivo 19 F/1 H imaging. The added improvement provided by the 6-element Rx-only array was quantified through simulation and measurement and compared to the ultimate SNR. It was verified through the measurement of isolation that microelectromechanical systems switches provided broadband isolation of Tx/Rx circuitry such that the 19 F tuned Tx/Rx array could be effectively used for both 19 F and 1 H nuclei. RESULTS For 1 H imaging, the measured Tx efficiency/homogeneity (mean ± percent SD; 6.79 μ T / kW ± 26 % ) was comparable to that simulated ( 7.57 μ T / kW ± 20 % ). The 6 additional Rx-only loops increased the mean Rx sensitivity when compared to the 8-element array by a factor of 1.41× and 1.45× in simulation and measurement, respectively. In regions central to the thorax, the simulated SNR of the 14-element array achieves ≥70% of the ultimate SNR when including noise from the matching circuits and preamplifiers. A measured microelectromechanical systems switching speed of 12 µs and added minimum 22 dB of isolation between Tx and Rx were sufficient for Tx/Rx switching in this application. CONCLUSION The described single-tuned array driven at 19 F and 1 H, utilizing microelectromechanical systems technology, provides excellent results for 19 F and 1 H dual-nuclear lung ventilation imaging.
Collapse
Affiliation(s)
- Adam Maunder
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Madhwesha Rao
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| | - Fraser Robb
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom.,GE Healthcare, Aurora, OH, USA
| | - Jim M Wild
- POLARIS, Imaging Group, Department of IICD, University of Sheffield, Sheffield, United Kingdom
| |
Collapse
|
8
|
Clément JD, Gruetter R, Ipek Ö. A human cerebral and cerebellar 8‐channel transceive RF dipole coil array at 7T. Magn Reson Med 2018; 81:1447-1458. [PMID: 30226637 DOI: 10.1002/mrm.27476] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2017] [Revised: 06/25/2017] [Accepted: 07/10/2018] [Indexed: 02/01/2023]
Abstract
PURPOSE Dipole antennas that provide high transmit field penetration with large coverage, and their use in a parallel transmit setup, may be advantageous in minimizing B 1 + -field inhomogeneities at ultra-high field, i.e 7T. We have developed and evaluated an 8-channel RF dipole coil array for imaging the entire cerebral and cerebellar regions in man. METHODS A coil array was modeled with seven dipoles: six placed covering the occipital and temporal lobes; one covering the parietal lobe; and two loops covering the frontal lobe. Center-shortened and fractionated dipoles were simulated for the array configuration and assessed with respect to B 1 + -field at maximum specific absorption rate averaged over 10 g tissue regions in human brain. The whole-brain center-shortened dipoles with frontal loops coil array was constructed and its transmit properties were assessed with respect to MR images, B 1 + -field, and homogeneity. RESULTS In simulations, the dipole arrays showed comparable performances to cover the whole-brain. However, for ease of construction, the center-shortened dipole was favored. High spatial resolution anatomical images of the human brain with the coil array demonstrated a full coverage of the cerebral cortex and cerebellum. CONCLUSIONS The 8-channel center-shortened dipoles and frontal loops coil array promises remarkable efficiency in highly challenging regions as the cerebellum, and phase-only RF shimming of whole-brain could greatly benefit ultra-high field magnetic resonance imaging of the human brain at 7T.
Collapse
Affiliation(s)
- Jérémie D. Clément
- LIFMET Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva Switzerland
| | - Rolf Gruetter
- LIFMET Ecole Polytechnique Fédérale de Lausanne (EPFL) Geneva Switzerland
- Department of Radiology University of Geneva Geneva Switzerland
- Department of Radiology University of Lausanne Lausanne Switzerland
| | | |
Collapse
|
9
|
Yan X, Zhang X, Xue R, Gore JC, Grissom WA. Optimizing the ICE decoupling element distance to improve monopole antenna arrays for 7 Tesla MRI. Magn Reson Imaging 2016; 34:1264-1268. [PMID: 27469314 DOI: 10.1016/j.mri.2016.07.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2016] [Revised: 07/19/2016] [Accepted: 07/21/2016] [Indexed: 11/15/2022]
Abstract
The induced current elimination (ICE) method has been previously applied to decouple monopole coil arrays in ultrahigh field MRI. However, the method creates low B1+ spots near the decoupling elements. In this study, we aim to improve the performance of ICE-decoupled monopole array in human head imaging at 7 Tesla. Eight-channel ICE-decoupled monopole arrays were optimized by varying the position of the decoupling elements. A series of numerical studies were performed using the co-simulation method. In simulation, decoupling performance, quality (Q-) values and transmit field (B1+) were comparatively investigated. In addition, we constructed an optimized ICE-decoupled monopole array and compared its performance with the unoptimized array. The simulation results showed that a good trade-off between decoupling and B1+ loss can be obtained when decoupling elements were moved 2.5-cm away from coil elements. This was validated by in-vivo MR imaging using the constructed array. Compared with the unoptimized ICE decoupled monopole array, the optimized array had a more homogeneous transmit field and no dark spots or signal cancellations in the MR images.
Collapse
Affiliation(s)
- Xinqiang Yan
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA; Department of Radiology, Vanderbilt University, Nashville, TN, USA.
| | - Xiaoliang Zhang
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, CA, USA; UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, CA, USA
| | - Rong Xue
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing, China
| | - John C Gore
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA; Department of Radiology, Vanderbilt University, Nashville, TN, USA
| | - William A Grissom
- Vanderbilt University Institute of Imaging Science, Vanderbilt University, Nashville, TN, USA; Department of Biomedical Engineering, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
10
|
Yan X, Wei L, Chu S, Xue R, Zhang X. Eight-Channel Monopole Array Using ICE Decoupling for Human Head MR Imaging at 7 T. APPLIED MAGNETIC RESONANCE 2016; 47:527-538. [PMID: 29033501 PMCID: PMC5638452 DOI: 10.1007/s00723-016-0775-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Revised: 03/09/2016] [Indexed: 06/03/2023]
Abstract
Due to the unique structure of radiative coil elements, traditional decoupling methods face technical challenges in reducing the electromagnetic coupling of the radiative arrays. In this study, we aim to investigate the possibility of using the recently introduced induced current elimination (ICE) decoupling technique for cylindrical shaped radiative coil array designs. To evaluate the method, an eight-channel transmit/receive monopole array with the ICE decoupling, suitable for human head imaging at 7 T, was built and comparatively investigated. In vivo human head images were acquired and geometry factor maps were measured and calculated to evaluate the performance of the ICE-decoupled monopole array. Compared with the monopole array without decoupling methods, the ICE-decoupled monopole array had a higher signal-to-noise ratio and demonstrated improved parallel imaging ability. The experimental results indicate that the ICE decoupling method is a promising solution to addressing the coupling issue of radiative array at ultrahigh fields.
Collapse
Affiliation(s)
- Xinqiang Yan
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China
- Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
- Beijing Engineering Research Center of Radiographic Techniques and Equipment, 19B Yuquan Road, Shijingshan District, Beijing 100049, China
| | - Long Wei
- Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
- Beijing Engineering Research Center of Radiographic Techniques and Equipment, 19B Yuquan Road, Shijingshan District, Beijing 100049, China
| | - Suoda Chu
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China
| | - Rong Xue
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China
- Beijing Institute for Brain Disorders, Beijing 100053, China
| | - Xiaoliang Zhang
- Department of Radiology and Biomedical Imaging, University of California San Francisco, Byers Hall, Room 102, 1700 4th ST, San Francisco, CA 941582330, USA
- UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, CA 94158, USA
| |
Collapse
|
11
|
Yan X, Cao Z, Zhang X. Simulation verification of SNR and parallel imaging improvements by ICE-decoupled loop array in MRI. APPLIED MAGNETIC RESONANCE 2016; 47:395-403. [PMID: 27034578 PMCID: PMC4808813 DOI: 10.1007/s00723-016-0764-x] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/21/2015] [Revised: 12/08/2015] [Indexed: 06/03/2023]
Abstract
Transmit/receive L/C loop arrays with the induced current elimination (ICE) or magnetic wall decoupling method has shown high signal-to-noise (SNR) and excellent parallel imaging ability for MR imaging at ultrahigh fields, e.g., 7 T. In this study, we aim to numerically analyze the performance of an eight-channel ICE-decoupled loop array at 7 T. Three dimensional (3-D) electromagnetic (EM) and radiofrequency (RF) circuit co-simulation approach was employed. The values of all capacitors were obtained by optimizing the S-parameters of all coil elements. The EM simulation accurately modeled the coil structure, the phantom and the excitation. All coil elements were well matched to 50 ohm and the isolation between any two coil elements was better -15 dB. The simulated S parameters were exactly similar with the experimental results, indicating the simulation results were reliable. Compared with the conventional capacitively decoupled array, the ICE-decoupled array had higher sensitivity at the peripheral areas of the image subjects due to the shielding effect of the decoupling loops. The increased receive sensitivity resulted in an improvement of signal intensity and SNR for the ICE-decoupled array.
Collapse
|
12
|
Yan X, Xue R, Zhang X. Closely-spaced double-row microstrip RF arrays for parallel MR imaging at ultrahigh fields. APPLIED MAGNETIC RESONANCE 2015; 46:1239-1248. [PMID: 26508810 PMCID: PMC4617305 DOI: 10.1007/s00723-015-0712-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Radiofrequency (RF) coil arrays with high count of elements, e.g., closely-spaced multi-row arrays, exhibit superior parallel imaging performance in MRI. However, it is technically challenging and time-consuming to build multi-row arrays due to complex coupling issues. This paper presents a novel and simple method for closely-spaced multi-row RF array designs. Induced current elimination (ICE) decoupling method has shown the capability of reducing coupling between microstrip elements from different rows. In this study, its capability for decoupling array elements from the same row was investigated and validated by bench tests, with an isolation improvement from -8.9 dB to -20.7 dB. Based on this feature, a closely-spaced double-row microstrip array with 16 elements was built at 7T. S21 between any two elements of the 16-channel closely-spaced was better than -14 dB. In addition, its feasibility and performance was validated by MRI experiments. No significant image reconstruction- related noise amplifications were observed for parallel imaging even when reduced factor (R) achieves 4. The experimental results demonstrated that the proposed design might be a simple and efficient approach in fabricating closely-spaced multi-row RF arrays.
Collapse
Affiliation(s)
- Xinqiang Yan
- Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
- Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing 100049, China
| | - Rong Xue
- State Key Laboratory of Brain and Cognitive Science, Beijing MRI Center for Brain Research, Institute of Biophysics, Chinese Academy of Sciences, Beijing 100101, China
| | - Xiaoliang Zhang
- Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California 94158, USA
- UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, California 94158, USA
| |
Collapse
|
13
|
Yan X, Zhang X. Decoupling and matching network for monopole antenna arrays in ultrahigh field MRI. Quant Imaging Med Surg 2015; 5:546-51. [PMID: 26435918 DOI: 10.3978/j.issn.2223-4292.2015.07.06] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
BACKGROUND Radiative coil arrays, e.g., dipole or monopole arrays, are increasingly used in MR signal excitation and reception for ultrahigh field MRI. Technically, it is challenging to suppress the electromagnetic (EM) coupling of radiative array elements due to their unique structures. METHODS In this study, we proposed a combined decoupling and matching network (DMN) for monopole arrays for MRI applications. Compared with separate decoupling network and matching network, the combined network proposed here needs less components and rather suitable for decoupling radiative arrays in MRI. RESULTS Our study shows that the transmission coefficient between two coupled monopoles can be reduced from -5 dB to -24.8 dB by using the combined DMN. It is also clearly demonstrated in this study that this decoupling method is a port decoupling method rather than an element decoupling method. CONCLUSIONS With the proposed DMN, the monopole coil provides locally strong and spatially diverse B1 fields, which is essential to the improvement of MR sensitivity and parallel imaging performance.
Collapse
Affiliation(s)
- Xinqiang Yan
- 1 Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China ; 2 Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing 100049, China ; 3 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA ; 4 UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, California, USA
| | - Xiaoliang Zhang
- 1 Key Laboratory of Nuclear Radiation and Nuclear Energy Technology, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China ; 2 Beijing Engineering Research Center of Radiographic Techniques and Equipment, Beijing 100049, China ; 3 Department of Radiology and Biomedical Imaging, University of California San Francisco, San Francisco, California, USA ; 4 UCSF/UC Berkeley Joint Graduate Group in Bioengineering, San Francisco, California, USA
| |
Collapse
|
14
|
Milshteyn E, Zhang X. The Need and Initial Practice of Parallel Imaging and Compressed Sensing in Hyperpolarized 13C MRI in vivo. ACTA ACUST UNITED AC 2015; 4. [PMID: 26900533 DOI: 10.4172/2167-7964.1000e133] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Eugene Milshteyn
- University of California Berkeley and University of California San Francisco Joint Bioengineering Program, USA; Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco (UCSF), USA
| | - Xiaoliang Zhang
- University of California Berkeley and University of California San Francisco Joint Bioengineering Program, USA; Department of Radiology and Biomedical Imaging, School of Medicine, University of California San Francisco (UCSF), USA
| |
Collapse
|