Li L, Camps J, Rodriguez B, Grau V. Solving the Inverse Problem of Electrocardiography for Cardiac Digital Twins: A Survey. IEEE Rev Biomed Eng 2025; 18:316-336. [PMID: 39453795 DOI: 10.1109/rbme.2024.3486439] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2024]
Abstract
Cardiac digital twins (CDTs) are personalized virtual representations used to understand complex cardiac mechanisms. A critical component of CDT development is solving the ECG inverse problem, which enables the reconstruction of cardiac sources and the estimation of patient-specific electrophysiology (EP) parameters from surface ECG data. Despite challenges from complex cardiac anatomy, noisy ECG data, and the ill-posed nature of the inverse problem, recent advances in computational methods have greatly improved the accuracy and efficiency of ECG inverse inference, strengthening the fidelity of CDTs. This paper aims to provide a comprehensive review of the methods for solving ECG inverse problems, their validation strategies, their clinical applications, and their future perspectives. For the methodologies, we broadly classify state-of-the-art approaches into two categories: deterministic and probabilistic methods, including both conventional and deep learning-based techniques. Integrating physics laws with deep learning models holds promise, but challenges such as capturing dynamic electrophysiology accurately, accessing accurate domain knowledge, and quantifying prediction uncertainty persist. Integrating models into clinical workflows while ensuring interpretability and usability for healthcare professionals is essential. Overcoming these challenges will drive further research in CDTs.
Collapse
|
2
|
Shi WR, Wu SH, Zou GC, Xu K, Jiang WF, Zhang Y, Qin M, Liu X. A novel approach for quantitative electrogram analysis for driver identification: Implications for ablation in persistent atrial fibrillation. Front Cardiovasc Med 2022; 9:1049854. [DOI: 10.3389/fcvm.2022.1049854] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Accepted: 11/14/2022] [Indexed: 12/04/2022] Open
Abstract
ObjectiveThis study sought to study the feasibility, efficacy, and safety of using multiscale entropy (MSE) analysis to guide catheter ablation for persistent atrial fibrillation (PsAF) and predict ablation outcomes.MethodsWe prospectively enrolled 108 patients undergoing initial ablation for PsAF. MSE was calculated based on bipolar intracardiac electrograms (iEGMs) to measure the dynamical complexity of biological signals. The iEGMs data were exported after pulmonary vein isolation (PVI), then calculated in a customed platform, and finally re-annotated into the CARTO system. After PVI, regions of the highest mean MSE (mMSE) values were ablated in descending order until AF termination, or three areas had been ablated.ResultsBaseline characteristics were evenly distributed between the AF termination (n = 38, 35.19%) and the non-termination group. The RA-to-LA mean MSE (mMSE) gradient demonstrated a positive gradient in the non-termination group and a negative gradient in the termination group (0.105 ± 0.180 vs. −0.235 ± 0.256, P < 0.001). During a 12-month follow-up, 29 patients (26.9%) had arrhythmia recurrence after single ablation, and 18 of them had AF (62.1%). The termination group had lower rates of arrhythmia recurrence (15.79 vs. 32.86%, Log-Rank P = 0.053) and AF recurrence (10.53 vs. 20%, Log-Rank P = 0.173) after single ablation and a lower rate of arrhythmia recurrence (7.89 vs. 27.14%, Log-Rank P = 0.018) after repeated ablation. Correspondingly, subjects with negative RA-to-LA mMSE gradient had lower incidences of arrhythmia (16.67 vs. 35%, Log-Rank P = 0.028) and AF (16.67 vs. 35%, Log-Rank P = 0.032) recurrence after single ablation and arrhythmia recurrence after repeated ablation (12.5 vs. 26.67%, Log-Rank P = 0.062). Marginal peri-procedural safety outcomes were observed.ConclusionMSE analysis-guided driver ablation in addition to PVI for PsAF could be feasible, efficient, and safe. An RA < LA mMSE gradient before ablation could predict freedom from arrhythmia. The RA-LA MSE gradient could be useful for guiding ablation strategy selection.
Collapse
|
3
|
Prats-Boluda G, Guillem MS, Rodrigo M, Ye-Lin Y, Garcia-Casado J. Identification of atrial fibrillation drivers by means of concentric ring electrodes. Comput Biol Med 2022; 148:105957. [PMID: 35981454 DOI: 10.1016/j.compbiomed.2022.105957] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2022] [Revised: 07/19/2022] [Accepted: 08/06/2022] [Indexed: 11/16/2022]
Abstract
BACKGROUND AND OBJECTIVE The prevalence of atrial fibrillation (AF) has tripled in the last 50 years due to population aging. High-frequency (DFdriver) activated atrial regions lead the activation of the rest of the atria, disrupting the propagation wavefront. Fourier based spectral analysis of body surface potential maps have been proposed for DFdriver identification, although these approaches present serious drawbacks due to their limited spectral resolution for short AF epochs and the blurring effect of the volume conductor. Laplacian signals (BC-ECG) from bipolar concentric ring electrodes (CRE) have been shown to outperform the spatial resolution achieved with conventional unipolar recordings. Our aimed was to determine the best DFdriver estimator in endocardial electrograms and to assess the BC-ECG capacity of CRE to quantify AF activity non-invasively. METHODS 31 AF episodes were simulated using realistic tridimensional models of the atria electrical activity and torso. Periodogram and autoregressive (AR) spectral estimators were computed and the percentile (P90th, P95th and P98th) to impose on the dominant frequencies (DFs) across whole atria to define the best DFdriver estimator evaluated. The identification of DFdriver on DFs from BC-ECG and unipolar surface signals with conventional disc electrodes was compared. RESULTS The best DFdriver estimator was P95th and AR order 100. BC-ECG signals allowed better detection of AF activity than unipolar signals, with a significantly greater percentage of electrode locations in which DFdriver was identified (p-value 0.0095). CONCLUSIONS The use of BC-ECG signals for body surface Laplacian potential mapping with CRE could be helpful for better AF diagnosis, prognosis and ablation procedures than those with conventional disk electrodes.
Collapse
Affiliation(s)
- Gema Prats-Boluda
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| | - María S Guillem
- ITACA Institute, Universitat Politècnica de València, Valencia, Spain.
| | - Miguel Rodrigo
- CommLab, Engineering Electronic Department, Universitat de València, Valencia, Spain.
| | - Yiyao Ye-Lin
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| | - Javier Garcia-Casado
- Centro de Investigación e Innovación en Bioingeniería, Universitat Politècnica de València, Valencia, Spain.
| |
Collapse
|
4
|
Salinet J, Molero R, Schlindwein FS, Karel J, Rodrigo M, Rojo-Álvarez JL, Berenfeld O, Climent AM, Zenger B, Vanheusden F, Paredes JGS, MacLeod R, Atienza F, Guillem MS, Cluitmans M, Bonizzi P. Electrocardiographic Imaging for Atrial Fibrillation: A Perspective From Computer Models and Animal Experiments to Clinical Value. Front Physiol 2021; 12:653013. [PMID: 33995122 PMCID: PMC8120164 DOI: 10.3389/fphys.2021.653013] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2021] [Accepted: 03/22/2021] [Indexed: 01/16/2023] Open
Abstract
Electrocardiographic imaging (ECGI) is a technique to reconstruct non-invasively the electrical activity on the heart surface from body-surface potential recordings and geometric information of the torso and the heart. ECGI has shown scientific and clinical value when used to characterize and treat both atrial and ventricular arrhythmias. Regarding atrial fibrillation (AF), the characterization of the electrical propagation and the underlying substrate favoring AF is inherently more challenging than for ventricular arrhythmias, due to the progressive and heterogeneous nature of the disease and its manifestation, the small volume and wall thickness of the atria, and the relatively large role of microstructural abnormalities in AF. At the same time, ECGI has the advantage over other mapping technologies of allowing a global characterization of atrial electrical activity at every atrial beat and non-invasively. However, since ECGI is time-consuming and costly and the use of electrical mapping to guide AF ablation is still not fully established, the clinical value of ECGI for AF is still under assessment. Nonetheless, AF is known to be the manifestation of a complex interaction between electrical and structural abnormalities and therefore, true electro-anatomical-structural imaging may elucidate important key factors of AF development, progression, and treatment. Therefore, it is paramount to identify which clinical questions could be successfully addressed by ECGI when it comes to AF characterization and treatment, and which questions may be beyond its technical limitations. In this manuscript we review the questions that researchers have tried to address on the use of ECGI for AF characterization and treatment guidance (for example, localization of AF triggers and sustaining mechanisms), and we discuss the technological requirements and validation. We address experimental and clinical results, limitations, and future challenges for fruitful application of ECGI for AF understanding and management. We pay attention to existing techniques and clinical application, to computer models and (animal or human) experiments, to challenges of methodological and clinical validation. The overall objective of the study is to provide a consensus on valuable directions that ECGI research may take to provide future improvements in AF characterization and treatment guidance.
Collapse
Affiliation(s)
- João Salinet
- Biomedical Engineering, Centre for Engineering, Modelling and Applied Social Sciences (CECS), Federal University of ABC, São Bernardo do Campo, Brazil
| | - Rubén Molero
- ITACA Institute, Universitat Politècnica de València, València, Spain
| | - Fernando S. Schlindwein
- School of Engineering, University of Leicester, United Kingdom and National Institute for Health Research, Leicester Cardiovascular Biomedical Research Centre, Glenfield Hospital, Leicester, United Kingdom
| | - Joël Karel
- Department of Data Science and Knowledge Engineering, Maastricht University, Maastricht, Netherlands
| | - Miguel Rodrigo
- Electronic Engineering Department, Universitat de València, València, Spain
| | - José Luis Rojo-Álvarez
- Department of Signal Theory and Communications and Telematic Systems and Computation, University Rey Juan Carlos, Madrid, Spain
| | - Omer Berenfeld
- Center for Arrhythmia Research, University of Michigan, Ann Arbor, MI, United States
| | - Andreu M. Climent
- ITACA Institute, Universitat Politècnica de València, València, Spain
| | - Brian Zenger
- Biomedical Engineering Department, Scientific Computing and Imaging Institute (SCI), and Cardiovascular Research and Training Institute (CVRTI), The University of Utah, Salt Lake City, UT, United States
| | - Frederique Vanheusden
- Department of Engineering, School of Science and Technology, Nottingham Trent University, Nottingham, United Kingdom
| | - Jimena Gabriela Siles Paredes
- Biomedical Engineering, Centre for Engineering, Modelling and Applied Social Sciences (CECS), Federal University of ABC, São Bernardo do Campo, Brazil
| | - Rob MacLeod
- Biomedical Engineering Department, Scientific Computing and Imaging Institute (SCI), and Cardiovascular Research and Training Institute (CVRTI), The University of Utah, Salt Lake City, UT, United States
| | - Felipe Atienza
- Cardiology Department, Hospital General Universitario Gregorio Marañón, Instituto de Investigación Sanitaria Gregorio Marañón, and Facultad de Medicina, Universidad Complutense de Madrid, Madrid, Spain
| | - María S. Guillem
- ITACA Institute, Universitat Politècnica de València, València, Spain
| | - Matthijs Cluitmans
- Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, Netherlands
| | - Pietro Bonizzi
- Department of Data Science and Knowledge Engineering, Maastricht University, Maastricht, Netherlands
| |
Collapse
|
5
|
Yang T, Pogwizd SM, Walcott GP, Yu L, He B. Noninvasive Activation Imaging of Ventricular Arrhythmias by Spatial Gradient Sparse in Frequency Domain-Application to Mapping Reentrant Ventricular Tachycardia. IEEE TRANSACTIONS ON MEDICAL IMAGING 2019; 38:525-539. [PMID: 30136937 PMCID: PMC6372101 DOI: 10.1109/tmi.2018.2866951] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
The aim of this paper is to develop and evaluate a novel imaging method [spatial gradient sparse in frequency domain (SSF)] for the reconstruction of activation sequences of ventricular arrhythmia from noninvasive body surface potential map (BSPM) measurements. We formulated and solved the electrocardiographic inverse problem in the frequency domain, and the activation time was encoded in the phase information of the imaging solution. A cellular automaton heart model was used to generate focal ventricular tachycardia (VT). Different levels of Gaussian white noise were added to simulate noise-contaminated BSPM. The performance of SSF was compared with that of weighted minimum norm inverse solution. We also evaluated the method in a swine model with simultaneous intracardiac and body surface recordings. Four reentrant VTs were observed in pigs with myocardial infarction generated by left anterior descending artery occlusion. The imaged activation sequences of reentrant VTs were compared with those obtained from intracardiac electrograms. In focal VT simulation, SSF has increased the correlation coefficient (CC) by 5% and decreased localization errors (LEs) by 2.7 mm on average under different noise levels. In the animal validation with reentrant VT, SSF has achieved an average CC of 88% and an average LE of 6.3 mm in localizing the earliest and latest activation site in the reentry circuit. Our promising results suggest that the SSF provides noninvasive imaging capability of detecting and mapping macro-reentrant circuits in 3-D ventricular space. The SSF may become a useful imaging tool of identifying and localizing the potential targets for ablation of focal and reentrant VT.
Collapse
Affiliation(s)
- Ting Yang
- Biomedical Engineering Department, University of Minnesota, Minneapolis, MN 55455, USA
| | - Steven M. Pogwizd
- Division of Cardiovascular Disease, School of Medicine, the University of Alabama at Birmingham, Birmingham, AL 0019, USA
| | - Gregory P. Walcott
- Division of Cardiovascular Disease, School of Medicine, the University of Alabama at Birmingham, Birmingham, AL 0019, USA
| | - Long Yu
- Biomedical Engineering Department, University of Minnesota, Minneapolis, MN 55455, USA
| | | |
Collapse
|
6
|
Systematic differences of non-invasive dominant frequency estimation compared to invasive dominant frequency estimation in atrial fibrillation. Comput Biol Med 2018; 104:299-309. [PMID: 30503301 PMCID: PMC6334202 DOI: 10.1016/j.compbiomed.2018.11.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2018] [Revised: 10/01/2018] [Accepted: 11/19/2018] [Indexed: 11/22/2022]
Abstract
Non-invasive analysis of atrial fibrillation (AF) using body surface mapping (BSM) has gained significant interest, with attempts at interpreting atrial spectro-temporal parameters from body surface signals. As these body surface signals could be affected by properties of the torso volume conductor, this interpretation is not always straightforward. This paper highlights the volume conductor effects and influences of the algorithm parameters for identifying the dominant frequency (DF) from cardiac signals collected simultaneously on the torso and atrial surface. Bi-atrial virtual electrograms (VEGMs) and BSMs were recorded simultaneously for 5 min from 10 patients undergoing ablation for persistent AF. Frequency analysis was performed on 4 s segments. DF was defined as the frequency with highest power between 4 and 10 Hz with and without applying organization index (OI) thresholds. The volume conductor effect was assessed by analyzing the highest DF (HDF) difference of each VEGM HDF against its BSM counterpart. Significant differences in HDF values between intra-cardiac and torso signals could be observed, independent of OI threshold. This difference increases with increasing endocardial HDF (BSM-VEGM median difference from -0.13 Hz for VEGM HDF at 6.25 ± 0.25 Hz to -4.24 Hz at 9.75 ± 0.25 Hz), thereby confirming the theory of the volume conductor effect in real-life situations. Applying an OI threshold strongly affected the BSM HDF area size and location and atrial HDF area location. These results suggest that volume conductor and measurement algorithm effects must be considered for appropriate clinical interpretation.
Collapse
|
7
|
Zhou S, Sapp JL, Dawoud F, Horacek BM. Localization of Activation Origin on Patient-Specific Epicardial Surface by Empirical Bayesian Method. IEEE Trans Biomed Eng 2018; 66:1380-1389. [PMID: 30281434 DOI: 10.1109/tbme.2018.2872983] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
OBJECTIVE Ablation treatment of ventricular arrhythmias can be facilitated by pre-procedure planning aided by electrocardiographic inverse solution, which can help to localize the origin of arrhythmia. Our aim was to improve localization accuracy of the inverse solution by using a novel Bayesian approach. METHODS The inverse problem of electrocardiography was solved by reconstructing epicardial potentials from 120 body-surface electrocardiograms and from patient-specific geometry of the heart and torso for four patients suffering from scar-related ventricular tachycardia who underwent epicardial catheter mapping, which included pace-mapping. Simulations using dipole sources in patient-specific geometry were also performed. The proposed method, using dynamic spatio-temporal a priori constraints of the solution, was compared with classical Tikhonov methods based on fixed constraints. RESULTS The mean localization error of the proposed method for all available pacing sites (n=78) was significantly smaller than that achieved by Tikhonov methods; specifically, the localization accuracy for pacing in the normal tissue (n=17) was [Formula: see text] mm (mean ± SD) versus [Formula: see text] mm reported in the previous study using the same clinical data and Tikhonov regularization. Simulation experiments further supported these clinical findings. CONCLUSION The promising results of in vivo and in silico experiments presented in this study provide a strong incentive to pursuing further investigation of data-driven Bayesian methods in solving the electrocardiographic inverse problem. SIGNIFICANCE The proposed approach to localizing origin of ventricular activation sequence may have important applications in pre-procedure assessment of arrhythmias and in guiding their ablation treatment.
Collapse
|
8
|
Cluitmans M, Brooks DH, MacLeod R, Dössel O, Guillem MS, van Dam PM, Svehlikova J, He B, Sapp J, Wang L, Bear L. Validation and Opportunities of Electrocardiographic Imaging: From Technical Achievements to Clinical Applications. Front Physiol 2018; 9:1305. [PMID: 30294281 PMCID: PMC6158556 DOI: 10.3389/fphys.2018.01305] [Citation(s) in RCA: 79] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2018] [Accepted: 08/29/2018] [Indexed: 11/23/2022] Open
Abstract
Electrocardiographic imaging (ECGI) reconstructs the electrical activity of the heart from a dense array of body-surface electrocardiograms and a patient-specific heart-torso geometry. Depending on how it is formulated, ECGI allows the reconstruction of the activation and recovery sequence of the heart, the origin of premature beats or tachycardia, the anchors/hotspots of re-entrant arrhythmias and other electrophysiological quantities of interest. Importantly, these quantities are directly and non-invasively reconstructed in a digitized model of the patient's three-dimensional heart, which has led to clinical interest in ECGI's ability to personalize diagnosis and guide therapy. Despite considerable development over the last decades, validation of ECGI is challenging. Firstly, results depend considerably on implementation choices, which are necessary to deal with ECGI's ill-posed character. Secondly, it is challenging to obtain (invasive) ground truth data of high quality. In this review, we discuss the current status of ECGI validation as well as the major challenges remaining for complete adoption of ECGI in clinical practice. Specifically, showing clinical benefit is essential for the adoption of ECGI. Such benefit may lie in patient outcome improvement, workflow improvement, or cost reduction. Future studies should focus on these aspects to achieve broad adoption of ECGI, but only after the technical challenges have been solved for that specific application/pathology. We propose 'best' practices for technical validation and highlight collaborative efforts recently organized in this field. Continued interaction between engineers, basic scientists, and physicians remains essential to find a hybrid between technical achievements, pathological mechanisms insights, and clinical benefit, to evolve this powerful technique toward a useful role in clinical practice.
Collapse
Affiliation(s)
- Matthijs Cluitmans
- Department of Cardiology, Cardiovascular Research Institute Maastricht Maastricht University, Maastricht, Netherlands
| | - Dana H. Brooks
- Department of Electrical and Computer Engineering, Northeastern University, Boston, MA, United States
| | - Rob MacLeod
- Biomedical Engineering Department, Scientific Computing and Imaging Institute (SCI), and Cardiovascular Research and Training Institute (CVRTI), The University of Utah, Salt Lake City, UT, United States
| | - Olaf Dössel
- Karlsruhe Institute of Technology, Karlsruhe, Germany
| | | | - Peter M. van Dam
- Donders Institute for Brain, Cognition and Behaviour, Radboud University Nijmegen Medical Center, Nijmegen, Netherlands
| | - Jana Svehlikova
- Institute of Measurement Science, Slovak Academy of Sciences, Bratislava, Slovakia
| | - Bin He
- Department of Biomedical Engineering Carnegie Mellon University, Pittsburgh, PA, United States
| | - John Sapp
- QEII Health Sciences Centre and Department of Medicine, Dalhousie University, Halifax, NS, Canada
| | - Linwei Wang
- Rochester Institute of Technology, Rochester, NY, United States
| | - Laura Bear
- IHU LIRYC, Fondation Bordeaux Université, Inserm U1045 and Université de Bordeaux, Bordeaux, France
| |
Collapse
|
9
|
Yang T, Yu L, Jin Q, Wu L, He B. Localization of Origins of Premature Ventricular Contraction by Means of Convolutional Neural Network From 12-Lead ECG. IEEE Trans Biomed Eng 2018; 65:1662-1671. [PMID: 28952932 PMCID: PMC6089373 DOI: 10.1109/tbme.2017.2756869] [Citation(s) in RCA: 39] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
OBJECTIVE This paper proposes a novel method to localize origins of premature ventricular contractions (PVCs) from 12-lead electrocardiography (ECG) using convolutional neural network (CNN) and a realistic computer heart model. METHODS The proposed method consists of two CNNs (Segment CNN and Epi-Endo CNN) to classify among ventricular sources from 25 segments and from epicardium (Epi) or endocardium (Endo). The inputs are the full time courses and the first half of QRS complexes of 12-lead ECG, respectively. After registering the ventricle computer model with an individual patient's heart, the training datasets were generated by multiplying ventricular current dipoles derived from single pacing at various locations with patient-specific lead field. The origins of PVC are localized by calculating the weighted center of gravity of classification returned by the CNNs. A number of computer simulations were conducted to evaluate the proposed method under a variety of noise levels and heart registration errors. Furthermore, the proposed method was evaluated on 90 PVC beats from nine human patients with PVCs and compared against ablation outcome in the same patients. RESULTS The computer simulation evaluation returned relatively high accuracies for Segment CNN (∼78%) and Epi-Endo CNN (∼90%). Clinical testing in nine PVC patients resulted an averaged localization error of 11 mm. CONCLUSION Our simulation and clinical evaluation results demonstrate the capability and merits of the proposed CNN-based method for localization of PVC. SIGNIFICANCE This paper suggests a new approach for cardiac source localization of origin of arrhythmias using only the 12-lead ECG by means of CNN, and may have important applications for future real-time monitoring and localizing origins of cardiac arrhythmias guiding ablation treatment.
Collapse
|
10
|
Yang T, Yu L, Jin Q, Wu L, He B. Activation recovery interval imaging of premature ventricular contraction. PLoS One 2018; 13:e0196916. [PMID: 29906289 PMCID: PMC6003683 DOI: 10.1371/journal.pone.0196916] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2018] [Accepted: 04/23/2018] [Indexed: 01/23/2023] Open
Abstract
Dispersion of ventricular repolarization due to abnormal activation contributes to the susceptibility to cardiac arrhythmias. However, the global pattern of repolarization is difficult to assess clinically. Activation recovery interval (ARI) has been used to understand the properties of ventricular repolarization. In this study, we developed an ARI imaging technique to noninvasively reconstruct three-dimensional (3D) ARI maps in 10 premature ventricular contraction (PVC) patients and evaluated the results with the endocardial ARI maps recorded by a clinical navigation system (CARTO). From the analysis results of a total of 100 PVC beats in 10 patients, the average correlation coefficient is 0.86±0.05 and the average relative error is 0.06±0.03. The average localization error is 4.5±2.3 mm between the longest ARI sites in 3D ARI maps and those in CARTO endocardial ARI maps. The present results suggest that ARI imaging could serve as an alternative of evaluating global pattern of ventricular repolarization noninvasively and could assist in the future investigation of the relationship between global repolarization dispersion and the susceptibility to cardiac arrhythmias.
Collapse
Affiliation(s)
- Ting Yang
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
| | - Long Yu
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
| | - Qi Jin
- Department of Cardiology, Shanghai Ruijin Hospital, Shanghai, China
| | - Liqun Wu
- Department of Cardiology, Shanghai Ruijin Hospital, Shanghai, China
| | - Bin He
- Department of Biomedical Engineering, University of Minnesota, Minneapolis, MN, United States of America
- Department of Biomedical Engineering, Carnegie Mellon University, Pittsburgh, PA, United States of America
| |
Collapse
|
11
|
Giffard-Roisin S, Delingette H, Jackson T, Webb J, Fovargue L, Lee J, Rinaldi CA, Razavi R, Ayache N, Sermesant M. Transfer Learning From Simulations on a Reference Anatomy for ECGI in Personalized Cardiac Resynchronization Therapy. IEEE Trans Biomed Eng 2018; 66:343-353. [PMID: 29993409 DOI: 10.1109/tbme.2018.2839713] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
GOAL Noninvasive cardiac electrophysiology (EP) model personalisation has raised interest for instance in the scope of predicting EP cardiac resynchronization therapy (CRT) response. However, the restricted clinical applicability of current methods is due in particular to the limitation to simple situations and the important computational cost. METHODS We propose in this manuscript an approach to tackle these two issues. First, we analyze more complex propagation patterns (multiple onsets and scar tissue) using relevance vector regression and shape dimensionality reduction on a large simulated database. Second, this learning is performed offline on a reference anatomy and transferred onto patient-specific anatomies in order to achieve fast personalized predictions online. RESULTS We evaluated our method on a dataset composed of 20 dyssynchrony patients with a total of 120 different cardiac cycles. The comparison with a commercially available electrocardiographic imaging (ECGI) method shows a good identification of the cardiac activation pattern. From the cardiac parameters estimated in sinus rhythm, we predicted five different paced patterns for each patient. The comparison with the body surface potential mappings (BSPM) measured during pacing and the ECGI method indicates a good predictive power. CONCLUSION We showed that learning offline from a large simulated database on a reference anatomy was able to capture the main cardiac EP characteristics from noninvasive measurements for fast patient-specific predictions. SIGNIFICANCE The fast CRT pacing predictions are a step forward to a noninvasive CRT patient selection and therapy optimisation, to help clinicians in these difficult tasks.
Collapse
|
12
|
Zhang Q, Yang C, Bai B. [Rhythm analysis of body surface potential mapping recordings from atrial fibrillation patients based on autocorrelation function]. SHENG WU YI XUE GONG CHENG XUE ZA ZHI = JOURNAL OF BIOMEDICAL ENGINEERING = SHENGWU YIXUE GONGCHENGXUE ZAZHI 2018; 35:161-170. [PMID: 29745519 PMCID: PMC9935089 DOI: 10.7507/1001-5515.201706096] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Received: 06/28/2017] [Indexed: 11/03/2022]
Abstract
The study of atrial fibrillation (AF) has been known as a hot topic of clinical concern. Body surface potential mapping (BSPM), a noninvasive electrical mapping technology, has been widely used in the study of AF. This study adopted 10 AF patients' preoperative and postoperative BSPM data (each patient's data contained 128 channels), and applied the autocorrelation function method to obtain the activation interval of the BSPM signals. The activation interval results were compared with that of manual counting method and the applicability of the autocorrelation function method was verified. Furthermore, we compared the autocorrelation function method with the commonly used fast Fourier transform (FFT) method. It was found that the autocorrelation function method was more accurate. Finally, to find a simple rule to predict the recurrence of atrial fibrillation, the autocorrelation function method was used to analyze the preoperative BSPM signals of 10 patients with persistent AF. Consequently, we found that if the patient's proportion of channels with dominant frequency larger than 2.5 Hz in the anterior left region is greater than the other three regions (the anterior right region, the posterior left region, and the posterior right region), he or she might have a higher possibility of AF recurrence. This study verified the rationality of the autocorrelation function method for rhythm analysis and concluded a simple rule of AF recurrence prediction based on this method.
Collapse
Affiliation(s)
- Qingzhou Zhang
- Department of Electronic Engineering, Fudan University, Shanghai 200433, P.R.China
| | - Cuiwei Yang
- Department of Electronic Engineering, Fudan University, Shanghai 200433, P.R.China;Key Laboratory of Medical Imaging Computing and Computer Assisted Intervention of Shanghai, Shanghai 200433, P.R.China;Shanghai Engineering Research Center of Assistive Devices, Shanghai 200093,
| | - Baodan Bai
- School of Medical Instrument, Shanghai University of Medicine and Health Sciences, Shanghai 201318, P.R.China
| |
Collapse
|
13
|
Bunch TJ. Mapping of atrial fibrillation: A test of faith. Heart Rhythm 2018. [PMID: 29522893 DOI: 10.1016/j.hrthm.2018.03.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
Affiliation(s)
- T Jared Bunch
- Intermountain Heart Institute, Intermountain Medical Center, Murray, Utah; Department of Internal Medicine, Stanford University, Palo Alto, California.
| |
Collapse
|
14
|
Liu J, Wang Y, Katscher U, He B. Electrical Properties Tomography Based on $B_{{1}}$ Maps in MRI: Principles, Applications, and Challenges. IEEE Trans Biomed Eng 2017; 64:2515-2530. [PMID: 28829299 PMCID: PMC5675043 DOI: 10.1109/tbme.2017.2725140] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
OBJECTIVE The purpose is to provide a comprehensive review of the electrical properties tomography (EPT) technique, which was introduced to image the electrical properties (EPs) of tissue noninvasively by exploiting the measured field data of MRI. METHODS We reviewed the principle of EPT, reconstruction methods, biomedical applications such as tumor imaging, and existing challenges. As a key application of EPT, the estimation of specific absorption rate (SAR) due to MRI was discussed in the background of elevated risk of tissue heating at high field. RESULTS AND CONCLUSION Since the originally proposed local, homogeneous Helmholtz equation-based reconstruction algorithm, advanced EPT algorithms have emerged to address the challenges of EPT, including reconstruction error near tissue boundaries, noise sensitivity, inaccurate phase estimation, and elimination of the unmeasurable component, along with demonstrations of in vivo experiments. EPT techniques have been applied to investigate EPs of both healthy and pathological tissues in vivo and factors contributing to various EP value, including sodium, water content, etc. More studies are anticipated to consolidate the current findings. EPT-based subject-specific SAR estimation has led to in vivo demonstration of its feasibility and prediction of temperature increase of phantom during MRI scans merely using measured data. SIGNIFICANCE EPT has the advantage of high resolution and practical feasibility in a clinical setup for imaging the biomedically interesting EPs of tissue in the radiofrequency range. EPT-based SAR estimation is another promising topic for predicting tissue heating of individual subjects during a specific MRI scan.
Collapse
Affiliation(s)
- Jiaen Liu
- Advanced MRI Section, Laboratory of Functional and Molecular Imaging, National Institute of Neurological Disorders and Stroke, National Institutes of Health, Bethesda, Maryland, 20892, USA
| | - Yicun Wang
- Department of Biomedical Engineering, University of Minnesota, Minnesota, 55455, USA
| | | | - Bin He
- Department of Biomedical Engineering and Institute for Engineering in Medicine, University of Minnesota, Minnesota, 55455, USA
| |
Collapse
|