Wilcox S, Sengupta S, Huang C, Tokuda J, Lu A, Woodrum D, Chen Y. Development of a Low-Profile, Piezoelectric Robot for MR-Guided Abdominal Needle Interventions. Ann Biomed Eng 2025:10.1007/s10439-025-03719-w. [PMID: 40266438 DOI: 10.1007/s10439-025-03719-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2024] [Accepted: 03/25/2025] [Indexed: 04/24/2025]
Abstract
PURPOSE Minimally invasive needle-based interventions are commonly used in cancer diagnosis and treatment, including procedures, such as biopsy, brachytherapy, and microwave ablation. Although MR-guided needle placement offers several distinct advantages, such as high-resolution target visualization and accurate device tracking, one of the primary limitations that affect its widespread adoption is the ergonomic constraints of the closed-bore MRI environment, requiring the patients to be frequently moved in and out to perform the needle-based procedures. This paper introduces a low-profile, body-mounted, MR-guided robot designed to address this limitation by streamlining the operation workflow and enabling accurate needle placement within the MRI scanner. METHODS The robot employs piezoelectric linear actuators and stacked Cartesian XY stages to precisely control the position and orientation of a needle guide. A kinematic model and control framework was developed to facilitate accurate targeting. Additionally, clinical workflow for the liver interventions was developed to demonstrate the robot's capability to replicate existing procedures. The proposed system was validated in benchtop environment and 3T MRI scanner to quantify the system performance. RESULTS Experimental validations conducted in free space demonstrated a position accuracy of 2.38 ± 0.94 mm and orientation error of 1.40 ± 2.89°. Additional tests to confirm MR-conditionality and MR-guided phantom placements were carried out to assess the system's performance and safety in MRI suite, yielding a position error of 2.01 ± 0.77 mm and an orientation error of 1.57 ± 1.31°. CONCLUSION The presented robot shows exceptional compatibility with a wide range of patients and bore sizes while maintaining clinically significant accuracy. Future work will focus on the validations in dynamic liver environments.
Collapse
Affiliation(s)
- Samuel Wilcox
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, 30332, USA
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA, 30332, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| | - Chuan Huang
- Department of Radiology and Imaging Sciences, Emory University, Atlanta, GA, 30322, USA
| | - Junichi Tokuda
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA, 02115, USA
| | - Aiming Lu
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | - David Woodrum
- Department of Radiology, Mayo Clinic, Rochester, MN, 55905, USA
| | - Yue Chen
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, Atlanta, GA, 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA, 30332, USA.
| |
Collapse
|
2
|
Huang Z, Gunderman AL, Wilcox SE, Sengupta S, Shah J, Lu A, Woodrum D, Chen Y. Body-Mounted MR-Conditional Robot for Minimally Invasive Liver Intervention. Ann Biomed Eng 2024; 52:2065-2075. [PMID: 38634953 DOI: 10.1007/s10439-024-03503-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 03/25/2024] [Indexed: 04/19/2024]
Abstract
MR-guided microwave ablation (MWA) has proven effective in treating hepatocellular carcinoma (HCC) with small-sized tumors, but the state-of-the-art technique suffers from sub-optimal workflow due to the limited accuracy provided by the manual needle insertions. This paper presents a compact body-mounted MR-conditional robot that can operate in closed-bore MR scanners for accurate needle guidance. The robotic platform consists of two stacked Cartesian XY stages, each with two degrees of freedom, that facilitate needle insertion pose control. The robot is actuated using 3D-printed pneumatic turbines with MR-conditional bevel gear transmission systems. Pneumatic valves and control mechatronics are located inside the MRI control room and are connected to the robot with pneumatic transmission lines and optical fibers. Free-space experiments indicated robot-assisted needle insertion error of 2.6 ± 1.3 mm at an insertion depth of 80 mm. The MR-guided phantom studies were conducted to verify the MR-conditionality and targeting performance of the robot. Future work will focus on the system optimization and validations in animal trials.
Collapse
Affiliation(s)
- Zhefeng Huang
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Anthony L Gunderman
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Samuel E Wilcox
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, 1161 21st Ave South Medical Center North, Nashville, TN, 37232, USA
| | - Jay Shah
- Department of Radiology, Emory University, 1364 Clifton Rd, Atlanta, GA, 30329, USA
| | - Aiming Lu
- Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA
| | - David Woodrum
- Department of Radiology, Mayo Clinic, 200 1st St SW, Rochester, MN, 55905, USA
| | - Yue Chen
- Institute of Robotics and Intelligent Machines, Georgia Institute of Technology, 801 Atlantic Dr NW, Atlanta, GA, 30332, USA.
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, 313 Ferst Dr, Atlanta, GA, 30332, USA.
| |
Collapse
|
3
|
Wang Y, Hrovat M, Kolandaivelu A, Gunderman AL, Halperin HR, Schmidt EJ, Chen Y. MR-Safe Cartesian Platform for Active Cardiac Shimming: Preliminary Validation. IEEE Trans Biomed Eng 2024; 71:2131-2142. [PMID: 38315598 PMCID: PMC11246563 DOI: 10.1109/tbme.2024.3362295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2024]
Abstract
OBJECTIVE Implanted Cardioverter Defibrillators (ICDs) induce a large (100 parts per million) inhomogeneous magnetic field in the magnetic resonance imaging (MRI) scanner which cannot be corrected by the scanner's built-in shim coils, leading to significant image artifacts that can make portions of the heart unreadable. To compensate for the field inhomogeneity, an active shim coil capable of countering the field deviation in user-defined regions was designed that must be optimally placed at patient-specific locations. We aim to develop and evaluate an MR-safe robotic solution for automated shim coil positioning. METHODS We designed and fabricated an MR-safe Cartesian platform that holds the shim coil inside the scanner. The platform consists of three lead screw stages actuated by pneumatic motors, achieving decoupled translations of 140 mm in each direction. The platform is made of plastics and fiberglass with the control electronics placed outside the scanner room, ensuring MR safety. Mechanical modeling was derived to provide design specifications. RESULTS Experiments show that the platform achieves less than 2 mm average motion error and 0.5 mm repeatability in all directions, and reduces the adjustment time from 5 min to a few seconds. Phantom and animal trials were conducted, showing that the proposed system is able to position a heavy shim coil ( kg) for improved ICD artifact suppression. CONCLUSION This robotic platform provides an effective method for reliable shim coil positioning inside the scanner. SIGNIFICANCE This work contributes to improving cardiac MRI quality that could facilitate accurate diagnosis and treatment planning for patients with implanted ICDs.
Collapse
|
4
|
Mo Z, Zhang X, Liang H, Chen Q, Tie C, Xiao W, Cao Q, Liu C, Zou C, Wan L, Zhang X, Li Y. A Novel Three-Channel Endorectal Coil for Prostate Magnetic Resonance Imaging at 3T. IEEE Trans Biomed Eng 2023; 70:3381-3388. [PMID: 37318962 DOI: 10.1109/tbme.2023.3286488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
OBJECTIVE The purpose of this work is to develop a 3-channel endorectal coil (ERC-3C) structure to obtain higher signal-to-noise (SNR) and better parallel imaging performance for prostate magnetic resonance imaging (MRI) at 3T. METHODS The coil performance was validated by in vivo studies and the SNR, g-factor, and diffusion-weighted imaging (DWI) were compared. A 2-channel endorectal coil (ERC-2C) with two orthogonal loops and a 12-channel external surface coil were employed for comparison. RESULTS Compared with the ERC-2C with a quadrature configuration and the external 12-channel coil array, the proposed ERC-3C improved SNR performance by 23.9% and 428.9%, respectively. The improved SNR enables the ERC-3C to produce spatial high-resolution images of 0.24 mm × 0.24 mm × 2 mm (0.1152 μL) in the prostate area within 9 minutes. CONCLUSION We developed an ERC-3C and validated its performance through in vivo MR imaging experiments. SIGNIFICANCE The results demonstrated the feasibility of an ERC with more than two channels and that a higher SNR can be achieved using the ERC-3C compared with an orthogonal ERC-2C of the same coverage.
Collapse
|
5
|
Jiang W, Gao Y, Wen M, Ye Z, Liang H, Wu D, Dong W. Preliminary evaluation for ultrasound-guided targeted prostate biopsy using a portable surgical robot: Ex vivo results. Int J Med Robot 2023:e2597. [PMID: 37984069 DOI: 10.1002/rcs.2597] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 10/17/2023] [Accepted: 10/26/2023] [Indexed: 11/22/2023]
Abstract
BACKGROUND Robotic systems are increasingly used to enhance clinical outcomes in prostate intervention. To evaluate the clinical value of the proposed portable robot, the robot-assisted and robot-targeted punctures were validated experimentally. METHOD The robot registration utilising the electromagnetic tracker achieves coordinate transformation from the ultrasound (US) image to the robot. Subsequently, Transrectal ultrasound (TRUS)-guided phantom trials were conducted for robot-assisted, free-hand, and robot-targeted punctures. RESULTS The accuracy of robot registration was 0.95 mm, and the accuracy of robot-assisted, free-hand, and robot-targeted punctures was 2.38 ± 0.64 mm, 3.11 ± 0.72 mm, and 3.29 ± 0.83 mm sequentially. CONCLUSION The registration method has been successfully applied to robot-targeted puncture. Current results indicate that the accuracy of robot-targeted puncture is slightly inferior to that of manual operations. Moreover, in manual operation, robot-assisted puncture improves the accuracy of free-hand puncture. Accuracy superior to 3.5 mm demonstrates the clinical applicability of both robot-assisted and robot-targeted punctures.
Collapse
Affiliation(s)
- Wenhe Jiang
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
| | - Yongzhuo Gao
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
| | - Mingwei Wen
- Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan, China
| | - Zhichao Ye
- Department of Urology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Huageng Liang
- Department of Urology, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
| | - Dongmei Wu
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
| | - Wei Dong
- State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin, China
| |
Collapse
|
6
|
Kobayashi S, King F, Hata N. Automatic segmentation of prostate and extracapsular structures in MRI to predict needle deflection in percutaneous prostate intervention. Int J Comput Assist Radiol Surg 2023; 18:449-460. [PMID: 36152168 PMCID: PMC9974805 DOI: 10.1007/s11548-022-02757-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2022] [Accepted: 09/13/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE Understanding the three-dimensional anatomy of percutaneous intervention in prostate cancer is essential to avoid complications. Recently, attempts have been made to use machine learning to automate the segmentation of functional structures such as the prostate gland, rectum, and bladder. However, a paucity of material is available to segment extracapsular structures that are known to cause needle deflection during percutaneous interventions. This research aims to explore the feasibility of the automatic segmentation of prostate and extracapsular structures to predict needle deflection. METHODS Using pelvic magnetic resonance imagings (MRIs), 3D U-Net was trained and optimized for the prostate and extracapsular structures (bladder, rectum, pubic bone, pelvic diaphragm muscle, bulbospongiosus muscle, bull of the penis, ischiocavernosus muscle, crus of the penis, transverse perineal muscle, obturator internus muscle, and seminal vesicle). The segmentation accuracy was validated by putting intra-procedural MRIs into the 3D U-Net to segment the prostate and extracapsular structures in the image. Then, the segmented structures were used to predict deflected needle path in in-bore MRI-guided biopsy using a model-based approach. RESULTS The 3D U-Net yielded Dice scores to parenchymal organs (0.61-0.83), such as prostate, bladder, rectum, bulb of the penis, crus of the penis, but lower in muscle structures (0.03-0.31), except and obturator internus muscle (0.71). The 3D U-Net showed higher Dice scores for functional structures ([Formula: see text]0.001) and complication-related structures ([Formula: see text]0.001). The segmentation of extracapsular anatomies helped to predict the deflected needle path in MRI-guided prostate interventions of the prostate with the accuracy of 0.9 to 4.9 mm. CONCLUSION Our segmentation method using 3D U-Net provided an accurate anatomical understanding of the prostate and extracapsular structures. In addition, our method was suitable for segmenting functional and complication-related structures. Finally, 3D images of the prostate and extracapsular structures could simulate the needle pathway to predict needle deflections.
Collapse
Affiliation(s)
- Satoshi Kobayashi
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA.
- Urology, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 8128582, Japan.
| | - Franklin King
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| | - Nobuhiko Hata
- National Center for Image Guided Therapy, Department of Radiology, Brigham and Women's Hospital and Harvard Medical School, 75 Francis Street, Boston, MA, 02115, USA
| |
Collapse
|
7
|
Li M, Mehralivand S, Xu S, Varble N, Bakhutashvili I, Gurram S, Pinto PA, Choyke PL, Wood BJ, Turkbey B. HoloLens augmented reality system for transperineal free-hand prostate procedures. J Med Imaging (Bellingham) 2023; 10:025001. [PMID: 36875636 PMCID: PMC9976411 DOI: 10.1117/1.jmi.10.2.025001] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Accepted: 02/09/2023] [Indexed: 03/05/2023] Open
Abstract
Purpose An augmented reality (AR) system was developed to facilitate free-hand real-time needle guidance for transperineal prostate (TP) procedures and to overcome the limitations of a traditional guidance grid. Approach The HoloLens AR system enables the superimposition of annotated anatomy derived from preprocedural volumetric images onto a patient and addresses the most challenging part of free-hand TP procedures by providing real-time needle tip localization and needle depth visualization during insertion. The AR system accuracy, or the image overlay accuracy ( n = 56 ), and needle targeting accuracy ( n = 24 ) were evaluated within a 3D-printed phantom. Three operators each used a planned-path guidance method ( n = 4 ) and free-hand guidance ( n = 4 ) to guide needles into targets in a gel phantom. Placement error was recorded. The feasibility of the system was further evaluated by delivering soft tissue markers into tumors of an anthropomorphic pelvic phantom via the perineum. Results The image overlay error was 1.29 ± 0.57 mm , and needle targeting error was 2.13 ± 0.52 mm . The planned-path guidance placements showed similar error compared to the free-hand guidance ( 4.14 ± 1.08 mm versus 4.20 ± 1.08 mm , p = 0.90 ). The markers were successfully implanted either into or in close proximity to the target lesion. Conclusions The HoloLens AR system can provide accurate needle guidance for TP interventions. AR support for free-hand lesion targeting is feasible and may provide more flexibility than grid-based methods, due to the real-time 3D and immersive experience during free-hand TP procedures.
Collapse
Affiliation(s)
- Ming Li
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States
| | - Sherif Mehralivand
- National Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States
| | - Sheng Xu
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States
| | - Nicole Varble
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States
- Philips Research of North America, Cambridge, Massachusetts, United States
| | - Ivane Bakhutashvili
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States
| | - Sandeep Gurram
- National Institutes of Health, Urologic Oncology Branch, National Cancer Institute, Bethesda, Maryland, United States
| | - Peter A. Pinto
- National Institutes of Health, Urologic Oncology Branch, National Cancer Institute, Bethesda, Maryland, United States
| | - Peter L. Choyke
- National Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States
| | - Bradford J. Wood
- National Institutes of Health, Center for Interventional Oncology, Radiology and Imaging Sciences, Clinical Center, Bethesda, Maryland, United States
| | - Baris Turkbey
- National Institutes of Health, Molecular Imaging Branch, National Cancer Institute, Bethesda, Maryland, United States
| |
Collapse
|
8
|
Wang Y, Kwok KW, Cleary K, Taylor RH, Iordachita I. Flexible Needle Bending Model for Spinal Injection Procedures. IEEE Robot Autom Lett 2023; 8:1343-1350. [PMID: 37637101 PMCID: PMC10448781 DOI: 10.1109/lra.2023.3239310] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/29/2023]
Abstract
An in situ needle manipulation technique used by physicians when performing spinal injections is modeled to study its effect on needle shape and needle tip position. A mechanics-based model is proposed and solved using finite element method. A test setup is presented to mimic the needle manipulation motion. Tissue phantoms made from plastisol as well as porcine skeletal muscle samples are used to evaluate the model accuracy against medical images. The effect of different compression models as well as model parameters on model accuracy is studied, and the effect of needle-tissue interaction on the needle remote center of motion is examined. With the correct combination of compression model and model parameters, the model simulation is able to predict needle tip position within submillimeter accuracy.
Collapse
Affiliation(s)
- Yanzhou Wang
- Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA
| | - Ka-Wai Kwok
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong, China
| | - Kevin Cleary
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Hospital, Washington, DC, USA
| | - Russell H Taylor
- Department of Computer Science and Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA
| | - Iulian Iordachita
- Department of Mechanical Engineering and Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA
| |
Collapse
|
9
|
Musa M, Sengupta S, Chen Y. Design of a 6-DoF Parallel Robotic Platform for MRI Applications. JOURNAL OF MEDICAL ROBOTICS RESEARCH 2022; 7:2241005. [PMID: 37614779 PMCID: PMC10445425 DOI: 10.1142/s2424905x22410057] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/25/2023]
Abstract
In this work, the design, analysis, and characterization of a parallel robotic motion generation platform with 6-degrees of freedom (DoF) for magnetic resonance imaging (MRI) applications are presented. The motivation for the development of this robot is the need for a robotic platform able to produce accurate 6-DoF motion inside the MRI bore to serve as the ground truth for motion modeling; other applications include manipulation of interventional tools such as biopsy and ablation needles and ultrasound probes for therapy and neuromodulation under MRI guidance. The robot is comprised of six pneumatic cylinder actuators controlled via a robust sliding mode controller. Tracking experiments of the pneumatic actuator indicates that the system is able to achieve an average error of 0.69 ± 0.14 mm and 0.67 ± 0.40 mm for step signal tracking and sinusoidal signal tracking, respectively. To demonstrate the feasibility and potential of using the proposed robot for minimally invasive procedures, a phantom experiment was performed in the benchtop environment, which showed a mean positional error of 1.20 ± 0.43 mm and a mean orientational error of 1.09 ± 0.57°, respectively. Experiments conducted in a 3T whole body human MRI scanner indicate that the robot is MRI compatible and capable of achieving positional error of 1.68 ± 0.31 mm and orientational error of 1.51 ± 0.32° inside the scanner, respectively. This study demonstrates the potential of this device to enable accurate 6-DoF motions in the MRI environment.
Collapse
Affiliation(s)
- Mishek Musa
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR 72701, USA
| | - Saikat Sengupta
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN 37232, USA
| | - Yue Chen
- Department of Biomedical Engineering, Georgia Institute of Technology/Emory University, Atlanta, GA 30332, USA
| |
Collapse
|
10
|
Limpabandhu C, Hu Y, Ren H, Song W, Tse Z. Towards catheter steering using magnetic tractor beam coupling. Proc Inst Mech Eng H 2022; 236:9544119221075400. [PMID: 35130770 PMCID: PMC8915239 DOI: 10.1177/09544119221075400] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Accepted: 12/21/2021] [Indexed: 11/17/2022]
Abstract
Catheters are used in various clinical applications, and the ability to direct the catheter to the desired location is critical for clinical outcomes. Steerable catheters assist clinicians to access targeted areas, notably the vascular bundles and major vessels, while causing no damage to the surrounding tissue. A novel catheter actuation technology for catheter steering is presented in this study. The technique is simple and relies on three magnetic couples interacting with one another to generate steering motions. A proof-of-concept catheter prototype demonstrated the capacity to remotely steer a catheter over 100 mm of distance and ±45° of angular positioning, showing the potential manoeuvrability for clinical applications. It is feasible to steer a catheter using this three-magnet pair approach with the great potential to be used for catheterisation procedures. The presented mechanism's kinematics and a near-form solution for catheter steering regardless of design factors will be studied in the future.
Collapse
Affiliation(s)
| | - Yihua Hu
- Department of Electronic Engineering, University of York, York, UK
| | - Hongliang Ren
- Department of Electronic Engineering, The Chinese University of Hong Kong, Hong Kong
| | - Wenzhan Song
- School of Electrical and Computer Engineering, University of Georgia, GA, USA
| | - Zion Tse
- Department of Electronic Engineering, University of York, York, UK
| |
Collapse
|
11
|
Musa MJ, Sharma K, Cleary K, Chen Y. Respiratory Compensated Robot for Liver Cancer Treatment: Design, Fabrication, and Benchtop Characterization. IEEE/ASME TRANSACTIONS ON MECHATRONICS 2022; 27:268-279. [DOI: 10.1109/tmech.2021.3062984] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
12
|
Mohammadbagherpoor H, Acemoglu A, Mattos LS, Caldwell D, Johnson JJ, Muth J, Grant E. Designing and Testing a Closed-loop Magnetically Actuated Laser Scanning System for Tissue Ablation. J Med Device 2021. [DOI: 10.1115/1.4053073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Abstract
Biomedical robotic systems continue to hold unlimited potential for surgical procedures. Robotized laser endoscopic tools provide surgeons with increased accuracy in the laser ablation of tissue and tumors. The research here catalogs the design and implementation of a new laser endoscopic tool for tissue ablation. A novel feature of this new device is the inclusion of a feedback loop that measures the position of the laser beam via a photo-detector sensor. The scale of this new device was governed by the dimensions of the photo-detector sensor. The tip of the laser's fiber optic cable is controlled by the torque interaction between permanent magnet rings surrounding the fiber optic and the custom designed solenoid coils. Prior to building the physical test-bed the system was modeled and simulated using COMSOL software. In pre-clinical trials, the physical experimental results showed that the designed prototype laser scanner system accurately track different ablation patterns and gives a consistent output position for the laser beam however, the heat diffusion into the tissue around the desired line of the geometric shape would give wider ablation margins than was desirable.
Collapse
Affiliation(s)
| | - Alperen Acemoglu
- Department of Advanced, Robotics, Istituto Italiano di, Tecnologia,Italy
| | - Leonardo S. Mattos
- Department of Advanced, Robotics, Istituto Italiano di, Tecnologia,Italy
| | - Darwin Caldwell
- Department of Advanced, Robotics, Istituto Italiano di, Tecnologia,Italy
| | | | - John Muth
- Department of Electrical and Computer Engineering, NC State University, Raleigh, NC 27606
| | - Edward Grant
- Department of Electrical and Computer Engineering, NC State University, Raleigh, NC 27606
| |
Collapse
|
13
|
Guo J, Liu Y, Qiu Q, Huang J, Liu C, Cao Z, Chen Y. A Novel Robotic Guidance System With Eye-Gaze Tracking Control for Needle-Based Interventions. IEEE Trans Cogn Dev Syst 2021. [DOI: 10.1109/tcds.2019.2959071] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
14
|
Xiao Q, Monfaredi R, Musa M, Cleary K, Chen Y. MR-Conditional Actuations: A Review. Ann Biomed Eng 2020; 48:2707-2733. [PMID: 32856179 PMCID: PMC10620609 DOI: 10.1007/s10439-020-02597-8] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2020] [Accepted: 08/14/2020] [Indexed: 10/23/2022]
Abstract
Magnetic resonance imaging (MRI) is one of the most prevailing technologies to enable noninvasive and radiation-free soft tissue imaging. Operating a robotic device under MRI guidance is an active research area that has the potential to provide efficient and precise surgical therapies. MR-conditional actuators that can safely drive these robotic devices without causing safety hazards or adversely affecting the image quality are crucial for the development of MR-guided robotic devices. This paper aims to summarize recent advances in actuation methods for MR-guided robots and each MR-conditional actuator was reviewed based on its working principles, construction materials, the noteworthy features, and corresponding robotic application systems, if any. Primary characteristics, such as torque, force, accuracy, and signal-to-noise ratio (SNR) variation due to the variance of the actuator, are also covered. This paper concludes with a perspective on the current development and future of MR-conditional actuators.
Collapse
Affiliation(s)
- Qingyu Xiao
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA
| | | | - Mishek Musa
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA
| | - Kevin Cleary
- Children's National Medical Center, Washington, DC, USA
| | - Yue Chen
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA.
| |
Collapse
|
15
|
Willmitzer F, Del Chicca F, Kircher PR, Wang-Leandro A, Kronen PW, Verdino D, Rüfenacht D, Porcellini B, Richter H. Diffusion-weighted and perfusion-weighted magnetic resonance imaging of the prostate gland of healthy adult dogs. Am J Vet Res 2019; 80:832-839. [PMID: 31449441 DOI: 10.2460/ajvr.80.9.832] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
OBJECTIVE To describe diffusion and perfusion characteristics of the prostate gland of healthy sexually intact adult dogs as determined by use of diffusion-weighted and perfusion-weighted MRI. ANIMALS 12 healthy sexually intact adult Beagles. PROCEDURES Ultrasonography of the prostate gland was performed. Subsequently, each dog was anesthetized, and morphological, diffusion-weighted, and perfusion-weighted MRI of the caudal aspect of the abdomen was performed. The apparent diffusion coefficient was calculated for the prostate gland parenchyma in diffusion-weighted MRI images in the central ventral and peripheral dorsal areas. Perfusion variables were examined in multiple regions of interest (ROIs) in the ventral and dorsal areas of the prostate gland and in the gluteal musculature. Signal intensity was determined, and a time-intensity curve was generated for each ROI. RESULTS Results of ultrasonographic examination of the prostate gland revealed no abnormalities for any dog. Median apparent diffusion coefficient of the prostate gland was 1.51 × 10-3 mm2/s (range, 1.04 × 10-3 mm2/s to 1.86 × 10-3 mm2/s). Perfusion-weighted MRI variables for the ROIs differed between the prostate gland parenchyma and gluteal musculature. CONCLUSIONS AND CLINICAL RELEVANCE Results provided baseline information about diffusion and perfusion characteristics of the prostate gland in healthy sexually intact adult dogs. Additional studies with dogs of various ages and breeds, with and without abnormalities of the prostate gland, will be necessary to validate these findings and investigate clinical applications.
Collapse
|
16
|
Pressure Observer Based Adaptive Dynamic Surface Control of Pneumatic Actuator with Long Transmission Lines. APPLIED SCIENCES-BASEL 2019. [DOI: 10.3390/app9173621] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
In this paper, the needle insertion motion control of a magnetic resonance imaging (MRI) compatible robot, which is actuated by a pneumatic cylinder with long transmission lines, is considered and a pressure observer based adaptive dynamic surface controller is proposed. The long transmission line is assumed to be an intermediate chamber connected between the control valve and the actuator in series, and a nonlinear first order system model is constructed to characterize the pressure losses and time delay brought by it. Due to the fact that MRI-compatible pressure sensors are not commercially available, a globally stable pressure observer is employed to estimate the chamber pressure. Based on the model of the long transmission line and the pressure observer, an adaptive dynamic surface controller is further designed by using the dynamic surface control technique. Compared to the traditional backstepping design method, the proposed controller can avoid the problem of “explosion of complexity” since the repeated differentiation of virtual controls is no longer required. The stability of the closed-loop system is analytically proven by employing the Lyapunov theory. Extensive experimental results are presented to demonstrate the effectiveness and the performance robustness of the proposed controller.
Collapse
|
17
|
Chen Y, Howard J, Godage I, Sengupta S. Closed Loop Control of an MR-Conditional Robot with Wireless Tracking Coil Feedback. Ann Biomed Eng 2019; 47:2322-2333. [PMID: 31218486 DOI: 10.1007/s10439-019-02311-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2019] [Accepted: 06/12/2019] [Indexed: 12/23/2022]
Abstract
This paper presents a hardware and software system to implement the task space control of an MR-conditional robot by integrating inductively coupled wireless coil based tracking feedback into the control loop. The main motivation of this work is to increase the accuracy performance and address the system uncertainties in the practical scenarios. We present the MR-conditional robot hardware design, wireless tracking method, and custom-designed communication software for real-time tracking data transfer. Based on these working principles, we fabricate the robot platform and evaluate the complete system with respect to various performance indices, i.e. data communication speed, targeting accuracy, tracking coil resolution, image quality, temperature variation, and task space control accuracy for static and dynamic targeting inside MRI scanner. The in-scanner targeting results show that the MR-conditional robot with wireless tracking coil feedback achieves the targeting error of 0.17 ± 0.08 mm, while the error calculated from the joint space optical encoder feedback is 0.68 ± 0.19 mm.
Collapse
Affiliation(s)
- Yue Chen
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, 72701, USA.
| | - Joseph Howard
- Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, 37212, USA
| | - Isuru Godage
- School of Computing, DePaul University, Chicago, IL, 60604, USA
| | - Saikat Sengupta
- Department of Radiology, Vanderbilt University Medical Center, Nashville, TN, 37232, USA
| |
Collapse
|
18
|
Venturi D, Glossop N, Bale R. Patient-specific templates for image-guided intervention - a phantom study. MINIM INVASIV THER 2019; 29:251-260. [PMID: 31204536 DOI: 10.1080/13645706.2019.1626251] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
Purpose: To evaluate the in vitro accuracy of a new device and method for simultaneous stereotactic CT-guided punctures.Material and methods: 240 needle paths were planned in 1 mm, 1.5 mm and 3 mm slice thickness with a custom-designed software. The data were transferred to a three-axis tabletop CNC machine that then drilled the hole pattern for the needles into square plastic plates. Kirschner wires were slid through the holes of the two parallel fixed plates to aim at the chosen targets inside the phantom. The accuracy was calculated by taking control CTs and measuring the Euclidean distance and the normal distance between the wire and the entry and target point.Results: The mean Euclidean distance of the wire tip to the target for the 1 mm, 1.5mm and 3 mm slice thickness were 2.5 mm (SD ± 0.64), 2.71mm (SD ± 0.78) and 2.8 mm (SD ± 1.0). The mean normal distance was 1.42 mm (SD ± 0.65), 1.43mm (SD ± 0.75) and 1.9 mm (SD ± 1.1), respectively.Conclusion: The system yields satisfactory accuracy comparable to other image-guided intervention systems. Involuntary movements of the patient need to be taken into account in a clinical setting.
Collapse
Affiliation(s)
- David Venturi
- Interventional Oncology - Microinvasive Therapy (SIP), Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria
| | - Neil Glossop
- Queen's University School of Computing, Kingston, Canada.,ArciTrax Inc, Toronto, Canada
| | - Reto Bale
- Interventional Oncology - Microinvasive Therapy (SIP), Department of Radiology, Medical University of Innsbruck, Innsbruck, Austria
| |
Collapse
|
19
|
Miura S, Kawamura K, Kobayashi Y, Fujie MG. Using Brain Activation to Evaluate Arrangements Aiding Hand-Eye Coordination in Surgical Robot Systems. IEEE Trans Biomed Eng 2018; 66:2352-2361. [PMID: 30582521 DOI: 10.1109/tbme.2018.2889316] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
GOAL To realize intuitive, minimally invasive surgery, surgical robots are often controlled using master-slave systems. However, the surgical robot's structure often differs from that of the human body, so the arrangement between the monitor and master must reflect this physical difference. In this study, we validate the feasibility of an embodiment evaluation method that determines the arrangement between the monitor and master. In our constructed cognitive model, the brain's intraparietal sulcus activates significantly when somatic and visual feedback match. Using this model, we validate a cognitively appropriate arrangement between the monitor and master. METHODS In experiments, we measure participants' brain activation using an imaging device as they control the virtual surgical simulator. Two experiments are carried out that vary the monitor and hand positions. CONCLUSION There are two common arrangements of the monitor and master at the brain activation's peak: One is placing the monitor behind the master, so the user feels that the system is an extension of his arms into the monitor; the other arranges the monitor in front of the master, so the user feels the correspondence between his own arm and the virtual arm in the monitor. SIGNIFICANCE From these results, we conclude that the arrangement between the monitor and master impacts embodiment, enabling the participant to feel apparent posture matches in master-slave surgical robot systems.
Collapse
|
20
|
Abstract
Purpose: A novel grid-template-mimicking MR-compatible robot was developed for in-gantry MRI-guided focal laser ablation of prostate cancer. Method: A substantially compact robot was designed and prototyped to meet in-gantry lithotomy ergonomics and allow for accommodation in the perineum. The controller software was reconfigured and integrated with the custom-designed navigation and multi-focal ablation software. Three experiments were conducted: (1) free space accuracy test; (2) phantom study under computed tomography (CT) guidance for image-guided accuracy test and overall workflow; and (3) magnetic resonance imaging (MRI)-guided focal laser ablation of an ex vivo prostate. The free space accuracy study included five targets that were selected across the workspace. The robot was then commanded five times to each target. The phantom study used a gel phantom made with color changing thermos-chromic ink, and four spherical metal fiducials were deployed with the robot. Then, laser ablation was applied, and the phantom was sliced for gross observation. For an MR-guided ex vivo test, a prostate from a donor who died of prostate cancer was obtained and multi-focally ablated using the system within the MRI gantry. The tissue was sliced after ablation for validation. Results: free-space accuracy was 0.38 ± 0.27 mm. The overall system targeting accuracy under CT guidance (including robot, registration, and insertion error) was 2.17 ± 0.47 mm. The planned ablation zone was successfully covered in both acrylamide gel phantom and in human prostate tissue. Conclusions: The new robot can accurately facilitate fiber targeting for MR-guided focal laser ablation of targetable prostate cancer.
Collapse
|
21
|
Chen Y, Godage I, Su H, Song A, Yu H. Stereotactic Systems for MRI-Guided Neurosurgeries: A State-of-the-Art Review. Ann Biomed Eng 2018; 47:335-353. [PMID: 30377898 DOI: 10.1007/s10439-018-02158-0] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2018] [Accepted: 10/17/2018] [Indexed: 10/28/2022]
Abstract
Recent technological developments in magnetic resonance imaging (MRI) and stereotactic techniques have significantly improved surgical outcomes. Despite the advantages offered by the conventional MRI-guided stereotactic neurosurgery, the robotic-assisted stereotactic approach has potential to further improve the safety and accuracy of neurosurgeries. This review aims to provide an update on the potential and continued growth of the MRI-guided stereotactic neurosurgical techniques by describing the state of the art in MR conditional stereotactic devices including manual and robotic-assisted. The paper also presents a detailed overview of MRI-guided stereotactic devices, MR conditional actuators and encoders used in MR conditional robotic-assisted stereotactic devices. The review concludes with several research challenges and future perspectives, including actuator and sensor technique, MR image guidance, and robot design issues.
Collapse
Affiliation(s)
- Yue Chen
- Department of Mechanical Engineering, University of Arkansas, Fayetteville, AR, USA.
| | - Isuru Godage
- School of Computing, DePaul University, Chicago, IL, USA
| | - Hao Su
- Department of Mechanical Engineering, City College of New York, New York, NY, USA
| | - Aiguo Song
- School of Instrument Science and Engineering, Southeast University, Nanjing, People's Republic of China
| | - Hong Yu
- Department of Neurological Surgery, Vanderbilt University, Nashville, TN, USA
| |
Collapse
|
22
|
Monfaredi R, Cleary K, Sharma K. MRI Robots for Needle-Based Interventions: Systems and Technology. Ann Biomed Eng 2018; 46:1479-1497. [PMID: 29922958 DOI: 10.1007/s10439-018-2075-x] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Accepted: 06/11/2018] [Indexed: 01/13/2023]
Abstract
Magnetic resonance imaging (MRI) provides high-quality soft-tissue images of anatomical structures and radiation free imaging. The research community has focused on establishing new workflows, developing new technology, and creating robotic devices to change an MRI room from a solely diagnostic room to an interventional suite, where diagnosis and intervention can both be done in the same room. Closed bore MRI scanners provide limited access for interventional procedures using intraoperative imaging. MRI robots could improve access and procedure accuracy. Different research groups have focused on different technology aspects and anatomical structures. This paper presents the results of a systematic search of MRI robots for needle-based interventions. We report the most recent advances in the field, present relevant technologies, and discuss possible future advances. This survey shows that robotic-assisted MRI-guided prostate biopsy has received the most interest from the research community to date. Multiple successful clinical experiments have been reported in recent years that show great promise. However, in general the field of MRI robotic systems is still in the early stage. The continued development of these systems, along with partnerships with commercial vendors to bring this technology to market, is encouraged to create new and improved treatment opportunities for future patients.
Collapse
Affiliation(s)
- Reza Monfaredi
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan ave. NW, Washington, DC, 20010, USA.
| | - Kevin Cleary
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan ave. NW, Washington, DC, 20010, USA
| | - Karun Sharma
- Sheikh Zayed Institute for Pediatric Surgical Innovation, Children's National Health System, 111 Michigan ave. NW, Washington, DC, 20010, USA.,Diagnostic Imaging and Radiology Department, Children's National Health System, 111 Michigan ave. NW, Washington, DC, 20010, USA
| |
Collapse
|