1
|
Zhang Y, Luo Z, Guo F. Simulation of electroporation threshold based on the evolution of transmembrane potential and pore density. PeerJ 2025; 13:e19356. [PMID: 40313387 PMCID: PMC12045266 DOI: 10.7717/peerj.19356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2024] [Accepted: 04/01/2025] [Indexed: 05/03/2025] Open
Abstract
To study the electric field threshold of electroporation of real cell membrane structures under the action of the pulsed electric field, in this article, a finite element model of the real cell containing endoplasmic reticulum and nucleus was constructed in real cell staining images by cluster segmentation and edge extraction techniques. The electroporation equation was introduced into the real cell model to calculate the threshold value of different membrane structures for electroporation under a pulsed electric field. The results showed that the transmembrane potentials of the cell membrane, endoplasmic reticulum membrane, and nuclear membrane reached the electroporation thresholds at 1.2, 2.6, and 2.9 kV/cm, while the pore density thresholds were 1.7 × 1014/m2, 3.2 × 1014/m2, and 3.5 × 1014/m2, respectively. Under a single pulse with a pulse width of 100 μs and rise and fall times of 10 μs, the pore density reaches the electroporation threshold at 1.7, 3.2 and 3.5 kV/cm, respectively.
Collapse
Affiliation(s)
- Yu Zhang
- Department of Gynecology, Chongqing Hospital of Traditional Chinese Medicine, Chongqing, China
| | - Zhijun Luo
- College of Automation, Chongqing University of Post and Telecommunications, Chongqing, China
| | - Fei Guo
- College of Automation, Chongqing University of Post and Telecommunications, Chongqing, China
| |
Collapse
|
2
|
Wang X, Bai Y, Zhang X, Li W, Yang J, Hu N. Hydrodynamic efficient cell capture and pairing method on microfluidic cell electrofusion chip. APL Bioeng 2025; 9:016111. [PMID: 40051781 PMCID: PMC11884867 DOI: 10.1063/5.0250472] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2024] [Accepted: 02/18/2025] [Indexed: 03/09/2025] Open
Abstract
Cell fusion is a widely employed process in various biological procedures, demonstrating significant application value in biotechnology. Cell pairing is a crucial manipulation for cell fusion. Standard fusion techniques, however, often provide poor and random cell contact, leading to low yields. In this study, we present a novel microfluidic device that utilizes a three-path symmetrical channel hydrodynamic capture method to achieve high-efficiency cell capture and pairing. The device contains several symmetrical channels and capture units, enabling three-path capture of two kinds of cells. To better understand the conditions necessary for effective cell pairing, we established a theoretical model of the three-path trapping flow field and conducted a qualitative force analysis on cells. Using K562 cells to explore the effect of different volumetric flow ratios of symmetric channels on cell capture and pairing efficiency, we finally got the optimized structure and obtained a single-cell capture efficiency of approximately 95.6 ± 2.0% and a cell pairing efficiency of approximately 83.3 ± 8.8%. Subsequently, electrofusion experiments were carried out on the paired cells, resulting in a fusion efficiency of approximately 77.8 ± 9.6%.
Collapse
Affiliation(s)
- Xuefeng Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Yaqi Bai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Xiaoling Zhang
- School of Smart Health, Chongqing College of Electronic Engineering, Chongqing 401331, China
| | - Wei Li
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| |
Collapse
|
3
|
Kumar M, Mishra A. A microdosimetry analysis of reversible electroporation in scattered, overlapping, and cancerous cervical cells. Biomed Phys Eng Express 2024; 10:035022. [PMID: 38479001 DOI: 10.1088/2057-1976/ad33a9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2023] [Accepted: 03/13/2024] [Indexed: 04/06/2024]
Abstract
We present a numerical method for studying reversible electroporation on normal and cancerous cervical cells. This microdosimetry analysis builds on a unique approach for extracting contours of free and overlapping cervical cells in the cluster from the Extended Depth of Field (EDF) images. The algorithm used for extracting the contours is a joint optimization of multiple-level set function along with the Gaussian mixture model and Maximally Stable Extremal Regions. These contours are then exported to a multi-physics domain solver, where a variable frequency pulsed electric field is applied. The trans-Membrane voltage (TMV) developed across the cell membrane is computed using the Maxwell equation coupled with a statistical approach, employing the asymptotic Smoluchowski equation. The numerical model was validated by successful replication of existing experimental configurations that employed low-frequency uni-polar pulses on the overlapping cells to obtain reversible electroporation, wherein, several overlapping clumps of cervical cells were targeted. For high-frequency calculation, a combination of normal and cancerous cells is introduced to the computational domain. The cells are assumed to be dispersive and the Debye dispersion equation is used for further calculations. We also present the resulting strength-duration relationship for achieving the threshold value of electroporation between the normal and cancerous cervical cells due to their size and conductivity differences. The dye uptake modulation during the high-frequency electric field electroporation is further advocated by a mathematical model.
Collapse
Affiliation(s)
- Mayank Kumar
- Department of Applied Science, Indian Institute of Information Technology Allahabad, India
| | - Ashutosh Mishra
- Department of Applied Science, Indian Institute of Information Technology Allahabad, India
| |
Collapse
|
4
|
Bai Y, Zhang X, Wang X, Xu M, Yang J, Hu N. Controllable and Stable Fusion Strategy on Microfluidics. Anal Chem 2024; 96:4437-4445. [PMID: 38501259 DOI: 10.1021/acs.analchem.3c04592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
This paper presents a microfluidic device with 200 cell "cage" structures. Based on this microfluidics device, a new simple and stable electrofusion method was developed. Under hydrodynamic force, the cells moved to the desired "cage" cell capture structure and efficiently formed cell pairs (∼80.0 ± 4.6%). Intimate intercellular connectivity was induced by the precise modulation of hypotonic solution substitution and the microstructure, which ensured no cell movement or displacement during the cell electroporation/electrofusion process. It also guaranteed repeated electroporation occurring in the same contact region and provided a stable cell membrane recombination and a cell fusion microenvironment. When the pulse signal was applied, a high fusion efficiency of ∼88.3 ± 0.6% was demonstrated on the microfluidic device.
Collapse
Affiliation(s)
- Yaqi Bai
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Xiaoling Zhang
- School of Smart Health, Chongqing College of Electronic Engineering, Chongqing 401331, China
| | - Xuefeng Wang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Mengli Xu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Jun Yang
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| | - Ning Hu
- Key Laboratory of Biorheological Science and Technology, Ministry of Education and Bioengineering College, Chongqing University, Chongqing 400044, China
| |
Collapse
|
5
|
Rembiałkowska N, Szlasa W, Radzevičiūtė-Valčiukė E, Kulbacka J, Novickij V. Negative effects of cancellation during nanosecond range High-Frequency calcium based electrochemotherapy in vitro. Int J Pharm 2023; 648:123611. [PMID: 37977287 DOI: 10.1016/j.ijpharm.2023.123611] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 11/13/2023] [Accepted: 11/14/2023] [Indexed: 11/19/2023]
Abstract
Drug delivery using nanosecond pulsed electric fields is a new branch of electroporation-based treatments, which potentially can substitute European standard operating procedures for electrochemotherapy. In this work, for the first time, we characterize the effects of ultra-fast repetition frequency (1-2.5 MHz) nanosecond pulses (5-9 kV/cm, 200 and 400 ns) in the context of nano-electrochemotherapy with calcium. Additionally, we investigate the feasibility of bipolar symmetric (↑200 ns + ↓200 ns) and asymmetric (↑200 ns + ↓400 ns) nanosecond protocols for calcium delivery. The effects of bipolar cancellation and the influence of interphase delay (200 ns) are overviewed. Human lung cancer cell lines A549 and H69AR were used as a model. It was shown that unipolar pulses delivered at high frequency are effective for electrochemotherapy with a significant improvement in efficiency when the delay between separate pulses is reduced. Bipolar symmetric pulses trigger the cancellation phenomenon limiting applications for drug delivery and can be compensated by the asymmetry of the pulse (↑200 ns + ↓400 ns or ↑400 ns + ↓200 ns). The results of this study can be successfully used to derive a new generation of nsPEF protocols for successful electrochemotherapy treatments.
Collapse
Affiliation(s)
- Nina Rembiałkowska
- Department of Molecular and Cellular Biology, Faculty of Pharmacy, Wroclaw Medical University, Wroclaw, Poland
| | - Wojciech Szlasa
- Department of Molecular and Cellular Biology, Faculty of Pharmacy, Wroclaw Medical University, Wroclaw, Poland
| | - Eivina Radzevičiūtė-Valčiukė
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania; State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania
| | - Julita Kulbacka
- Department of Molecular and Cellular Biology, Faculty of Pharmacy, Wroclaw Medical University, Wroclaw, Poland; State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania.
| | - Vitalij Novickij
- Faculty of Electronics, Vilnius Gediminas Technical University, Vilnius, Lithuania; State Research Institute Centre for Innovative Medicine, Department of Immunology and Bioelectrochemistry, Vilnius, Lithuania.
| |
Collapse
|
6
|
Kumar M, Kumar S, Chakrabartty S, Poulose A, Mostafa H, Goyal B. Dispersive Modeling of Normal and Cancerous Cervical Cell Responses to Nanosecond Electric Fields in Reversible Electroporation Using a Drift-Step Rectifier Diode Generator. MICROMACHINES 2023; 14:2136. [PMID: 38138305 PMCID: PMC10745406 DOI: 10.3390/mi14122136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/22/2023] [Revised: 11/16/2023] [Accepted: 11/18/2023] [Indexed: 12/24/2023]
Abstract
This paper creates an approximate three-dimensional model for normal and cancerous cervical cells using image processing and computer-aided design (CAD) tools. The model is then exposed to low-frequency electric pulses to verify the work with experimental data. The transmembrane potential, pore density, and pore radius evolution are analyzed. This work adds a study of the electrodeformation of cells under an electric field to investigate cytoskeleton integrity. The Maxwell stress tensor is calculated for the dispersive bi-lipid layer plasma membrane. The solid displacement is calculated under electric stress to observe cytoskeleton integrity. After verifying the results with previous experiments, the cells are exposed to a nanosecond pulsed electric field. The nanosecond pulse is applied using a drift-step rectifier diode (DSRD)-based generator circuit. The cells' transmembrane voltage (TMV), pore density, pore radius evolution, displacement of the membrane under electric stress, and strain energy are calculated. A thermal analysis of the cells under a nanosecond pulse is also carried out to prove that it constitutes a non-thermal process. The results showed differences in normal and cancerous cell responses to electric pulses due to changes in morphology and differences in the cells' electrical and mechanical properties. This work is a model-driven microdosimetry method that could be used for diagnostic and therapeutic purposes.
Collapse
Affiliation(s)
- Mayank Kumar
- Technical Research Analyst (TRA), Electronics/Biomedical Engineering, Aranca, Mumbai 400076, Maharastra, India;
| | - Sachin Kumar
- Department of Electronics and Communication Engineering, Galgotias College of Engineering and Technology, Greater Noida 201310, Uttar Pradesh, India;
| | - Shubhro Chakrabartty
- School of Computer Science Engineering and Applications, D Y Patil International University, Pune 411044, Maharastra, India
| | - Alwin Poulose
- School of Data Science, Indian Institute of Science Education and Research Thiruvananthapuram (IISER TVM), Vithura, Thiruvananthapuram 695551, Kerala, India
| | - Hala Mostafa
- Department of Information Technology, College of Computer and Information Sciences, Princess Nourah bint Abdulrahman University, P.O. Box 84428, Riyadh 11671, Saudi Arabia;
| | - Bhawna Goyal
- University Centre for Research and Development, Chandigarh University, Gharuan, Mohali 140413, Punjab, India;
| |
Collapse
|
7
|
Rao X, Chen S, Alfadhl Y, Chen X, Sun L, Yu L, Zhou J. Pulse width and intensity effects of pulsed electric fields on cancerous and normal skin cells. Sci Rep 2022; 12:18039. [PMID: 36302879 PMCID: PMC9613658 DOI: 10.1038/s41598-022-22874-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 10/20/2022] [Indexed: 01/24/2023] Open
Abstract
Microsecond pulsed electric fields (PEF) have previously been used for various tumour therapies, such as gene therapy, electrochemotherapy and irreversible electroporation (IRE), due to its demonstrated ability. However, recently nanosecond pulsed electric fields (nsPEF) have also been used as a potential tumor therapy via inducing cell apoptosis or immunogenic cell death to prevent recurrence and metastasis by interacting with intracellular organelles. A large proportion of the existing in-vitro studies of nsPEF on cells also suggests cell necrosis and swelling/blebbing can be induced, but the replicability and potential for other effects on cells suggesting a complicated process which requires further investigation. Therefore, this study investigated the effects of pulse width and intensity of nsPEF on the murine melanoma cells (B16) and normal murine fibroblast cells (L929) through electromagnetic simulation and in-vitro experiments. Through examining the evolution patterns of potential difference and electric fields on the intracellular compartments, the simulation has shown a differential effect of nsPEF on normal and cancerous skin cells, which explains well the results observed in the reported experiments. In addition, the modelling has provided a clear evidence that a few hundreds of ns PEF may have caused a mixed mode of effects, i.e. a 'cocktail effect', including cell electroporation and IRE due to an over their threshold voltage induced on the plasma membrane, as well as cell apoptosis and other biological effects caused by its interaction with the intracellular compartments. The in-vitro experiments in the pulse range of the hundreds of nanoseconds showed a possible differential cytotoxicity threshold of electric field intensity between B16 cells and L929 cells.
Collapse
Affiliation(s)
- Xin Rao
- grid.411963.80000 0000 9804 6672School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Sophia Chen
- grid.7445.20000 0001 2113 8111School of Medicine, Imperial College London, London, SW7 2AZ UK
| | - Yasir Alfadhl
- grid.4868.20000 0001 2171 1133School of Electronic Engineering and Computer Science, Queen Mary University of London, London, E1 4NS UK
| | - Xiaodong Chen
- grid.411963.80000 0000 9804 6672School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China ,grid.4868.20000 0001 2171 1133School of Electronic Engineering and Computer Science, Queen Mary University of London, London, E1 4NS UK
| | - Lingling Sun
- grid.411963.80000 0000 9804 6672School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Liyang Yu
- grid.411963.80000 0000 9804 6672School of Electronics and Information, Hangzhou Dianzi University, Hangzhou, 310018 China
| | - Jun Zhou
- grid.54549.390000 0004 0369 4060School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu, 610054 China
| |
Collapse
|
8
|
Kumar M, Mishra A. Reversible electroporation study of realistic normal and cancerous cervical cells model using avalanche transistor-based nano pulse generator. Biomed Phys Eng Express 2021; 7. [PMID: 34488195 DOI: 10.1088/2057-1976/ac240b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2021] [Accepted: 09/06/2021] [Indexed: 11/12/2022]
Abstract
In this paper, we study the reversible electroporation process on normal and cancerous cervical cells. The 2D contour of the cervical cells is extracted using image processing techniques from the Pap smear images. The conductivity change in the cancer cell model has been used to differentiate the effects of the high-frequency electric field on normal and cancerous cells. The cells' dielectric constant modulates when this high-frequency pulse is applied based on the Debye relaxation. To computationally visualize the effects of the electroporation on the cell membrane, the Smoluchowski equation is employed to estimate pore density, and Maxwell equations are used to determine the electric potential developed across the membrane of the cervical cell. The results demonstrate the suitability of this mathematical model for studying the response of normal and cancerous cells under electric stress. The electric field is supplied with the help of a realistic pulse generator which is designed on the principle of Marx circuit and avalanche transistor-based operations to produce a Gaussian pulse. The paper here uses a strength-duration curve to differentiate the electric field and time in nanoseconds required to electroporate normal and cancerous cells.
Collapse
Affiliation(s)
- Mayank Kumar
- Indian Institute of Information Technology Allahabad, Department of Applied Sciences (Biomedical Engineering), India
| | - Ashutosh Mishra
- Indian Institute of Information Technology Allahabad, Department of Applied Sciences (Biomedical Engineering), India
| |
Collapse
|
9
|
Guo F, Qian K, Zhang L, Deng H, Li X, Zhou J, Wang J. Anisotropic conductivity for single-cell electroporation simulation with tangentially dispersive membrane. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138426] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
10
|
Ultrathin glass fiber microprobe for electroporation of arbitrary selected cell groups. Bioelectrochemistry 2020; 135:107545. [PMID: 32446151 DOI: 10.1016/j.bioelechem.2020.107545] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2019] [Revised: 04/22/2020] [Accepted: 04/29/2020] [Indexed: 12/21/2022]
Abstract
A new type of ultrathin fiber microprobe for selective electroporation is reported. The microprobe is 10 cm long and has a diameter of 350 µm. This microprobe is a low cost tool, which allows electroporation of an arbitrary selected single cell or groups of cells among population with use of a standard microscope and cell culture plates. The microprobe in its basic form contains two metal microelectrodes made of a silver-copper alloy, running along the fiber, each with a diameter of 23 µm. The probe was tested in vitro on a population of normal and cancer cells. Successful targeted electroporation was observed by means of accumulation of trypan blue (TB) dye marker in the cell. The electroporation phenomenon was also verified with propidium iodide and AnnexinV in fluorescent microscopy.
Collapse
|