1
|
Dang Y, Zhang J, Chen J, Jiang T, Han J. YoMo: Yoshimura Continuum Manipulator for MR Environment. Soft Robot 2025; 12:268-279. [PMID: 39388237 DOI: 10.1089/soro.2023.0262] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2024] Open
Abstract
Origami robots have garnered attention due to their versatile deformation and potential applications, particularly for medical applications. In this article, we propose a Yoshimura continuum manipulator (YoMo) that can achieve accurate control of the tip position for the magnetic resonance (MR) environment. The YoMo made of a single piece of paper is cable-actuated to generate the bending and shortening deformation. The paper-based YoMo attached to an arc frame can readily function under different orientations in the MR environment. The design and fabrication of YoMo were formulated according to the Yoshimura folding pattern. The kinematics model based on constant curvature assumption was derived as a benchmark method to predict the tip position of the YoMo. The Koopman operator theory was applied to describe the relationship between the tip position and the length change under different orientations. The linear quadratic regulator integrated into the Koopman-based model (K-LQR) was adopted to achieve the trajectory tracking. Comprehensive experiments were carried out to examine the proposed YoMo, its modeling and control methods. The performance of the YoMo including stiffness and workspace was characterized via a customized test setup. The Koopman-based method demonstrates the superiority over the constant curvature-based model to predict the tip position. The K-LQR control method was examined with different trajectories, and the impact of the orientation, speed, and different trajectories were taken into consideration. The results demonstrate the YoMo is capable of achieving trajectory tracking with satisfied accuracy, indicating its potential for medical applications in the MR environment.
Collapse
Affiliation(s)
- Yu Dang
- College of Artificial Intelligence, Nankai University, Tianjin, China
- Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, Nankai University, Tianjin, China
- Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin, China
- Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen, China
| | - Jingyu Zhang
- College of Artificial Intelligence, Nankai University, Tianjin, China
- Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, Nankai University, Tianjin, China
- Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin, China
- Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen, China
| | - Jie Chen
- College of Artificial Intelligence, Nankai University, Tianjin, China
- Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, Nankai University, Tianjin, China
- Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin, China
- Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen, China
| | - Tianyu Jiang
- Department of Rehabilitation Medicine, The Second Medical Center, Chinese PLA General Hospital, Beijing, China
- National Clinical Research Center for Geriatric Diseases, Beijing, China
- National Key Laboratory of Kidney Diseases, Beijing, China
| | - Jianda Han
- College of Artificial Intelligence, Nankai University, Tianjin, China
- Engineering Research Center of Trusted Behavior Intelligence, Ministry of Education, Nankai University, Tianjin, China
- Tianjin Key Laboratory of Intelligent Robotics, Nankai University, Tianjin, China
- Institute of Intelligence Technology and Robotic Systems, Shenzhen Research Institute of Nankai University, Shenzhen, China
| |
Collapse
|
2
|
Wang B, Tao K, Hu X, Chen W, Wen Z, Liu X, You C, Geng Z, Li X, Liu R, Wu D. Intravascular Optical Coherence Tomography Utilizing a Miniature Piezoelectric-Driven Probe. IEEE Trans Biomed Eng 2023; 70:3490-3500. [PMID: 37379179 DOI: 10.1109/tbme.2023.3290210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/30/2023]
Abstract
Intravascular optical coherence tomography (IV-OCT) is crucial for evaluating lumen dimensions and guiding interventional procedures. However, traditional catheter-based IV-OCT faces challenges in achieving precise and full-field 360° imaging in tortuous vessels. Current IV-OCT catheters that employ proximal actuators and torque coils are susceptible to non-uniform rotational distortion (NURD) in tortuous vessels, while distal micromotor-driven catheters struggle with complete 360° imaging due to wiring artifacts. In this study, we developed a miniature optical scanning probe with an integrated piezoelectric-driven fiber optic slip ring (FOSR) to facilitate smooth navigation and precise imaging within tortuous vessels. The FOSR features a coil spring-wrapped optical lens serving as a rotor, enabling efficient 360° optical scanning. The structurally-and-functionally-integrated design significantly streamlines the probe (with a diameter of 0.85 mm and a length of 7 mm) while maintaining an excellent rotational speed of 10,000 rpm. High-precision 3D printing technology ensures accurate optical alignment of the fiber and lens inside the FOSR, with a maximum insertion loss variation of 2.67 dB during probe rotation. Finally, a vascular model demonstrated smooth probe insertion into the carotid artery, and imaging of oak leaf, metal rod phantoms, and ex vivo porcine vessels verified its capabilities for precise optical scanning, comprehensive 360° imaging, and artifact elimination. The FOSR probe exhibits small size, rapid rotation, and optical precision scanning, rendering it exceptionally promising for cutting-edge intravascular optical imaging techniques.
Collapse
|
3
|
Patel D, Nguyen A, Fleeting C, Patel AB, Mumtaz M, Lucke-Wold B. Precision medicine in neurosurgery: The evolving role of theranostics. INNOSC THERANOSTICS & PHARMACOLOGICAL SCIENCES 2023; 6:417. [PMID: 37601162 PMCID: PMC10439809 DOI: 10.36922/itps.417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
Theranostics in neurosurgery is a rapidly advancing field of precision medicine that combines diagnostic and therapeutic modalities to optimize patient outcomes. This approach has the potential to provide real-time feedback during therapy and diagnose a condition while simultaneously providing treatment. One such form of theranostics is focused ultrasound, which has been found to be effective in inducing neuroablation and neuromodulation and improving the efficacy of chemotherapy drugs by disrupting the blood-brain barrier. Targeted radionuclide therapy, which pairs positron emission tomography tracers with therapeutic effects and imaging modalities, is another promising form of theranostics for neurosurgery. Automated pathology analysis is yet another form of theranostics that can provide real-time feedback during the surgical resection of tumors. Electrical stimulation has also shown promise in optimizing therapies for patients with cerebral palsy. Overall, theranostics is a cost-effective way to optimize medical care for patients in neurosurgery. It is a relatively new field, but the advancements made so far show great promise for improving patient outcomes.
Collapse
Affiliation(s)
- Drashti Patel
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| | - Andrew Nguyen
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| | - Chance Fleeting
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| | - Anjali B. Patel
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| | - Mohammed Mumtaz
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| | - Brandon Lucke-Wold
- Department of Neurosurgery, University of Florida, College of Medicine, Gainesville, Florida, USA
| |
Collapse
|
4
|
Manjila S, Rosa B, Price K, Manjila R, Mencattelli M, Dupont PE. Robotic Instruments Inside the MRI Bore: Key Concepts and Evolving Paradigms in Imaging-enhanced Cranial Neurosurgery. World Neurosurg 2023; 176:127-139. [PMID: 36639101 DOI: 10.1016/j.wneu.2023.01.025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2023] [Accepted: 01/08/2023] [Indexed: 01/12/2023]
Abstract
Intraoperative MRI has been increasingly used to robotically deliver electrodes and catheters into the human brain using a linear trajectory with great clinical success. Current cranial MR guided robotics do not allow for continuous real-time imaging during the procedure because most surgical instruments are not MR-conditional. MRI guided robotic cranial surgery can achieve its full potential if all the traditional advantages of robotics (such as tremor-filtering, precision motion scaling, etc.) can be incorporated with the neurosurgeon physically present in the MRI bore or working remotely through controlled robotic arms. The technological limitations of design optimization, choice of sensing, kinematic modeling, physical constraints, and real-time control had hampered early developments in this emerging field, but continued research and development in these areas over time has granted neurosurgeons far greater confidence in using cranial robotic techniques. This article elucidates the role of MR-guided robotic procedures using clinical devices like NeuroBlate and Clearpoint that have several thousands of cases operated in a "linear cranial trajectory" and planned clinical trials, such as LAANTERN for MR guided robotics in cranial neurosurgery using LITT and MR-guided putaminal delivery of AAV2 GDNF in Parkinson's disease. The next logical improvisation would be a steerable curvilinear trajectory in cranial robotics with added DOFs and distal tip dexterity to the neurosurgical tools. Similarly, the novel concept of robotic actuators that are powered, imaged, and controlled by the MRI itself is discussed in this article, with its potential for seamless cranial neurosurgery.
Collapse
Affiliation(s)
- Sunil Manjila
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
| | - Benoit Rosa
- ICube Laboratory, UMR 7357 CNRS-University of Strasbourg, Strasbourg, France
| | - Karl Price
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Rehan Manjila
- Swanson School of Engineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA
| | - Margherita Mencattelli
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Pierre E Dupont
- Department of Cardiovascular Surgery, Boston Children's Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
5
|
Najafi G, Kreiser K, Abdelaziz MEMK, Hamady MS. Current State of Robotics in Interventional Radiology. Cardiovasc Intervent Radiol 2023; 46:549-561. [PMID: 37002481 PMCID: PMC10156773 DOI: 10.1007/s00270-023-03421-1] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Accepted: 03/11/2023] [Indexed: 05/04/2023]
Abstract
As a relatively new specialty with a minimally invasive nature, the field of interventional radiology is rapidly growing. Although the application of robotic systems in this field shows great promise, such as with increased precision, accuracy, and safety, as well as reduced radiation dose and potential for teleoperated procedures, the progression of these technologies has been slow. This is partly due to the complex equipment with complicated setup procedures, the disruption to theatre flow, the high costs, as well as some device limitations, such as lack of haptic feedback. To further assess these robotic technologies, more evidence of their performance and cost-effectiveness is needed before their widespread adoption within the field. In this review, we summarise the current progress of robotic systems that have been investigated for use in vascular and non-vascular interventions.
Collapse
Affiliation(s)
- Ghazal Najafi
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK.
| | - Kornelia Kreiser
- Department of Neuroradiology, Rehabilitations - und Universitätskliniken Ulm, 89081, Ulm, Germany
| | - Mohamed E M K Abdelaziz
- The Hamlyn Centre, Imperial College London, London, SW7 2AZ, UK
- Department of Electrical and Electronic Engineering, Faculty of Engineering, Imperial College London, London, SW7 2AZ, UK
| | - Mohamad S Hamady
- Department of Surgery and Cancer, Faculty of Medicine, Imperial College London, London, SW7 2AZ, UK
- The Hamlyn Centre, Imperial College London, London, SW7 2AZ, UK
| |
Collapse
|
6
|
Su H, Kwok KW, Cleary K, Iordachita I, Cavusoglu MC, Desai JP, Fischer GS. State of the Art and Future Opportunities in MRI-Guided Robot-Assisted Surgery and Interventions. PROCEEDINGS OF THE IEEE. INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS 2022; 110:968-992. [PMID: 35756185 PMCID: PMC9231642 DOI: 10.1109/jproc.2022.3169146] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Magnetic resonance imaging (MRI) can provide high-quality 3-D visualization of target anatomy, surrounding tissue, and instrumentation, but there are significant challenges in harnessing it for effectively guiding interventional procedures. Challenges include the strong static magnetic field, rapidly switching magnetic field gradients, high-power radio frequency pulses, sensitivity to electrical noise, and constrained space to operate within the bore of the scanner. MRI has a number of advantages over other medical imaging modalities, including no ionizing radiation, excellent soft-tissue contrast that allows for visualization of tumors and other features that are not readily visible by other modalities, true 3-D imaging capabilities, including the ability to image arbitrary scan plane geometry or perform volumetric imaging, and capability for multimodality sensing, including diffusion, dynamic contrast, blood flow, blood oxygenation, temperature, and tracking of biomarkers. The use of robotic assistants within the MRI bore, alongside the patient during imaging, enables intraoperative MR imaging (iMRI) to guide a surgical intervention in a closed-loop fashion that can include tracking of tissue deformation and target motion, localization of instrumentation, and monitoring of therapy delivery. With the ever-expanding clinical use of MRI, MRI-compatible robotic systems have been heralded as a new approach to assist interventional procedures to allow physicians to treat patients more accurately and effectively. Deploying robotic systems inside the bore synergizes the visual capability of MRI and the manipulation capability of robotic assistance, resulting in a closed-loop surgery architecture. This article details the challenges and history of robotic systems intended to operate in an MRI environment and outlines promising clinical applications and associated state-of-the-art MRI-compatible robotic systems and technology for making this possible.
Collapse
Affiliation(s)
- Hao Su
- Department of Mechanical and Aerospace Engineering, North Carolina State University, Raleigh, NC 27695 USA
| | - Ka-Wai Kwok
- Department of Mechanical Engineering, The University of Hong Kong, Hong Kong
| | - Kevin Cleary
- Children's National Health System, Washington, DC 20010 USA
| | - Iulian Iordachita
- Laboratory for Computational Sensing and Robotics (LCSR), Johns Hopkins University, Baltimore, MD 21218 USA
| | - M Cenk Cavusoglu
- Department of Electrical, Computer, and Systems Engineering, Case Western Reserve University, Cleveland, OH 44106 USA
| | - Jaydev P Desai
- Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, GA 30332 USA
| | - Gregory S Fischer
- Department of Robotics Engineering, Worcester Polytechnic Institute, Worcester, MA 01609 USA
| |
Collapse
|
7
|
Hofstetter LW, Hadley JR, Merrill R, Pham H, Fine GC, Parker DL. MRI-compatible electromagnetic servomotor for image-guided medical robotics. COMMUNICATIONS ENGINEERING 2022; 1:4. [PMID: 36700241 PMCID: PMC9873480 DOI: 10.1038/s44172-022-00001-y] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/22/2022] [Indexed: 02/01/2023]
Abstract
The soft-tissue imaging capabilities of magnetic resonance imaging (MRI) combined with high precision robotics has the potential to improve the precision and safety of a wide range of image-guided medical procedures. However, functional MRI-compatible robotics have not yet been realized in part because conventional electromagnetic servomotors can become dangerous projectiles near the strong magnetic field of an MRI scanner. Here we report an electromagnetic servomotor constructed from non-magnetic components, where high-torque and controlled rotary actuation is produced via interaction between electrical current in the servomotor armature and the magnetic field generated by the superconducting magnet of the MRI scanner itself. Using this servomotor design, we then build and test an MRI-compatible robot which can achieve the linear forces required to insert a large-diameter biopsy instrument in tissue during simultaneous MRI. Our electromagnetic servomotor can be safely operated (while imaging) in the patient area of a 3 Tesla clinical MRI scanner.
Collapse
Affiliation(s)
- Lorne W. Hofstetter
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| | - J. Rock Hadley
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| | - Robb Merrill
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| | - Huy Pham
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| | - Gabriel C. Fine
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| | - Dennis L. Parker
- Department of Radiology and Imaging Sciences, University of Utah School of Medicine, 30 North 1900 East #1A071, Salt Lake City, UT 84132 USA
| |
Collapse
|
8
|
Tavakkolmoghaddam F, Rajamani DK, Szewczyk B, Zhao Z, Gandomi K, Sekhar SC, Pilitsis J, Nycz C, Fischer G. NeuroPlan: A Surgical Planning Toolkit for an MRI-Compatible Stereotactic Neurosurgery Robot. ... INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS. INTERNATIONAL SYMPOSIUM ON MEDICAL ROBOTICS 2021; 2021:10.1109/ismr48346.2021.9661581. [PMID: 35789074 PMCID: PMC9248070 DOI: 10.1109/ismr48346.2021.9661581] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The adoption of robotic image-guided surgeries has enabled physicians to perform therapeutic and diagnostic procedures with less invasiveness and higher accuracy. One example is the MRI-guided stereotactic robotic-assisted surgery for conformal brain tumor ablation, where the robot is used to position and orient a thin probe to target a desired region within the brain. Requirements such as the remote center of motion and precise manipulation, impose the use of complex kinematic structures, which result in non-trivial workspaces in these robots. The lack of workspace visualization poses a challenge in selecting valid entry and target points during the surgical planning and navigation stage. In this paper, we present a surgical planning toolkit called the "NeuroPlan" for our MRI-compatible stereotactic neurosurgery robot developed as a module for 3D Slicer software. This toolkit streamlines the current surgical workflow by rendering and overlaying the robot's reachable workspace on the MRI image. It also assists with identifying the optimal entry point by segmenting the cranial burr hole volume and locating its center. We demonstrate the accuracy of the workspace rendering and burr hole parameter detection through both phantom and MR-images acquired from previously conducted animal studies.
Collapse
Affiliation(s)
| | - Dhruv Kool Rajamani
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
| | - Benjamin Szewczyk
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
- Department of Neurosurgery, Albany Medical Center, Albany NY
| | - Zhanyue Zhao
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
| | - Katie Gandomi
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
| | | | - Julie Pilitsis
- Department of Neurosurgery, Albany Medical Center, Albany NY
- Department of Neuroscience and Experimental Therapeutics, Albany Medical Center, Albany NY
| | - Christopher Nycz
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
| | - Gregory Fischer
- Robotics Engineering Department, Worcester Polytechnic Institute, Worcester MA
| |
Collapse
|
9
|
Antoniou A, Drakos T, Giannakou M, Evripidou N, Georgiou L, Christodoulou T, Panayiotou N, Ioannides C, Zamboglou N, Damianou C. Simple methods to test the accuracy of MRgFUS robotic systems. Int J Med Robot 2021; 17:e2287. [PMID: 34021694 PMCID: PMC8365756 DOI: 10.1002/rcs.2287] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2021] [Revised: 05/21/2021] [Accepted: 05/21/2021] [Indexed: 01/09/2023]
Abstract
BACKGROUND Robotic-assisted diagnostic and therapeutic modalities require a highly accurate performance to be certified for clinical application. In this paper, three simple methods for assessing the accuracy of motion of magnetic resonance-guided focused ultrasound (MRgFUS) robotic systems are presented. METHODS The accuracy of motion of a 4 degrees of freedom robotic system intended for preclinical use of MRgFUS was evaluated by calliper-based and magnetic resonance imaging (MRI) methods, as well as visually by performing multiple ablations on a plastic film. RESULTS The benchtop results confirmed a highly accurate motion in all axes of operation. The spatial positioning errors estimated by MRI evaluation were defined by the size of the imaging pixels. Lesions arrangement in discrete and overlapping patterns confirmed satisfactory alignment of motion trajectories. CONCLUSIONS We believe the methods presented here should serve as a standard for evaluating the accuracy of motion of MRgFUS robotic systems.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and InformaticsCyprus University of TechnologyLimassolCyprus
| | | | | | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and InformaticsCyprus University of TechnologyLimassolCyprus
| | | | | | | | | | | | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and InformaticsCyprus University of TechnologyLimassolCyprus
| |
Collapse
|
10
|
Gandomi KY, Carvalho PAWG, Tarasek M, Fiveland EW, Bhushan C, Williams E, Neubauer P, Zhao Z, Pilitsis J, Yeo D, Nycz CJ, Burdette E, Fischer GS. Modeling of Interstitial Ultrasound Ablation for Continuous Applicator Rotation With MR Validation. IEEE Trans Biomed Eng 2021; 68:1838-1846. [PMID: 32924937 PMCID: PMC8189669 DOI: 10.1109/tbme.2020.3023849] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was 1.27 °C. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.
Collapse
|