Meng L, Xu S, Hu Q, Wang H, Wang P, Li R, Zhang Y, Shi T, Kong N, Zhu X. Mild Focused Ultrasound-Induced Microscopic Heating of Nanoparticles Observed by Lanthanide Luminescence for Precise Sonothermal Cancer Therapy. NANO LETTERS 2025; 25:391-400. [PMID: 39710968 DOI: 10.1021/acs.nanolett.4c05175] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2024]
Abstract
Focused ultrasound (FUS) is a recognized tool that can be used clinically for the thermal ablation of tumors. However, excessive heat can cause side effects on the ultrasound transmission path and normal tissues around the tumor. To address the issue, this work detected for the first time the effect of microscopic heating of nanoparticles under the action of FUS through the luminescence intensity ratio (LIR) and luminescence lifetime of temperature-responsive lanthanide-doped nanoparticles. When FUS is applied to the tissue embedded with nanoparticles, the increase in the microscopic temperature of the nanoparticles synchronously monitored by LIR is more obvious than the increase in the macroscopic temperature. Based on this phenomenon, the intensity of focused ultrasound can be finely regulated to avoid overheating while ensuring a therapeutic effect. This work achieves the measurement of the microscopic heating of nanoparticles under FUS, which is of great significance for the development of sonothermal cancer therapy.
Collapse
Affiliation(s)
- Lingkai Meng
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Sixin Xu
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Qian Hu
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Hao Wang
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Pengrui Wang
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Ruotong Li
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Yifeng Zhang
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Tiange Shi
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Na Kong
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
| | - Xingjun Zhu
- School of Physical Science and Technology, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
- State Key Laboratory of Advanced Medical Materials and Devices, ShanghaiTech University, 393 Middle Huaxia Road, Shanghai, 201210, P. R. China
- Shanghai Clinical Research and Trial Center, Shanghai 201210, China
| |
Collapse
|
2
|
Rahpeima R, Lin CA. A comprehensive numerical procedure for high-intensity focused ultrasound ablation of breast tumour on an anatomically realistic breast phantom. PLoS One 2024; 19:e0310899. [PMID: 39352893 PMCID: PMC11444401 DOI: 10.1371/journal.pone.0310899] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2024] [Accepted: 09/09/2024] [Indexed: 10/04/2024] Open
Abstract
High-Intensity Focused Ultrasound (HIFU) as a promising and impactful modality for breast tumor ablation, entails the precise focalization of high-intensity ultrasonic waves onto the tumor site, culminating in the generation of extreme heat, thus ablation of malignant tissues. In this paper, a comprehensive three-dimensional (3D) Finite Element Method (FEM)-based numerical procedure is introduced, which provides exceptional capacity for simulating the intricate multiphysics phenomena associated with HIFU. Furthermore, the application of numerical procedures to an anatomically realistic breast phantom (ARBP) has not been explored before. The integrity of the present numerical procedure has been established through rigorous validation, incorporating comparative assessments with previous two-dimensional (2D) simulations and empirical data. For ARBP ablation, the administration of a 0.1 MPa pressure input pulse at a frequency of 1.5 MHz, sustained at the focal point for 10 seconds, manifests an ensuing temperature elevation to 80°C. It is noteworthy that, in contrast, the prior 2D simulation using a 2D phantom geometry reached just 72°C temperature under the identical treatment regimen, underscoring the insufficiency of 2D models, ascribed to their inherent limitations in spatially representing acoustic energy, which compromises their overall effectiveness. To underscore the versatility of this numerical platform, a simulation of a more clinically relevant HIFU therapy procedure has been conducted. This scenario involves the repositioning of the ultrasound focal point to three separate lesions, each spaced at 3 mm intervals, with ultrasound exposure durations of 6 seconds each and a 5-second interval for movement between focal points. This approach resulted in a more uniform high-temperature distribution at different areas of the tumour, leading to the ablation of almost all parts of the tumour, including its verges. In the end, the effects of different abnormal tissue shapes are investigated briefly as well. For solid mass tumors, 67.67% was successfully ablated with one lesion, while rim-enhancing tumors showed only 34.48% ablation and non-mass enhancement tumors exhibited 20.32% ablation, underscoring the need for multiple lesions and tailored treatment plans for more complex cases.
Collapse
Affiliation(s)
- Reza Rahpeima
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| | - Chao-An Lin
- Department of Power Mechanical Engineering, National Tsing Hua University, Hsinchu, Taiwan
| |
Collapse
|
3
|
Hosseinpour A, Soltani M, Souri M. Improving tumor treatment through intratumoral injection of drug-loaded magnetic nanoparticles and low-intensity ultrasound. Sci Rep 2024; 14:1452. [PMID: 38228704 PMCID: PMC10791673 DOI: 10.1038/s41598-024-52003-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Accepted: 01/12/2024] [Indexed: 01/18/2024] Open
Abstract
The intratumoral injection of therapeutic agents responsive to external stimuli has gained considerable interest in treating accessible tumors due to its biocompatibility and capacity to reduce side effects. For the first time, a novel approach is explored to investigate the feasibility of utilizing low-intensity ultrasound in combination with intratumoral injection of drug-loaded magnetic nanoparticles (MNPs) to thermal necrosis and chemotherapy with the objective of maximizing tumor damage while avoiding harm to surrounding healthy tissue. In this study, a mathematical framework is proposed based on a multi-compartment model to evaluate the effects of ultrasound transducer's specifications, MNPs size and distribution, and drug release in response to the tumor microenvironment characteristics. The results indicate that while a higher injection rate may increase interstitial fluid pressure, it also simultaneously enhances the concentration of the therapeutic agent. Moreover, by increasing the power and frequency of the transducer, the acoustic pressure and intensity can be enhanced. This, in turn, increases the impact on accumulated MNPs, resulting in a rise in temperature and localized heat generation. Results have demonstrated that smaller MNPs have a lower capacity to generate heat compared to larger MNPs, primarily due to the impact of sound waves on them. It is worth noting that smaller MNPs have been observed to have enhanced diffusion, allowing them to effectively spread within the tumor. However, their smaller size also leads to rapid elimination from the extracellular space into the bloodstream. To summarize, this study demonstrated that the local injection of MNPs carrying drugs not only enables localized chemotherapy but also enhances the effectiveness of low-intensity ultrasound in inducing tissue thermal necrosis. The findings of this study can serve as a valuable and reliable resource for future research in this field and contribute to the development of personalized medicine.
Collapse
Affiliation(s)
- Asma Hosseinpour
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran
| | - Madjid Soltani
- Department of Mechanical Engineering, K. N. Toosi University of Technology, Tehran, Iran.
- Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Canada.
- Centre for Biotechnology and Bioengineering (CBB), University of Waterloo, Waterloo, Canada.
- Department of Integrative Oncology, BC Cancer Research Institute, Vancouver, Canada.
- Centre for Sustainable Business, International Business University, Toronto, Canada.
| | - Mohammad Souri
- Department of NanoBiotechnology, Pasteur Institute of Iran, Tehran, Iran
| |
Collapse
|
4
|
Holman R, Guillemin PC, Lorton O, Desgranges S, Contino-Pépin C, Salomir R. Assessing Enhanced Acoustic Absorption From Sonosensitive Perfluorocarbon Emulsion With Magnetic Resonance-Guided High-Intensity Focused Ultrasound and a Percolated Tissue-Mimicking Flow Phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1510-1517. [PMID: 37117139 DOI: 10.1016/j.ultrasmedbio.2023.01.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2022] [Revised: 01/18/2023] [Accepted: 01/25/2023] [Indexed: 05/17/2023]
Abstract
OBJECTIVE Sonosensitive high-boiling point perfluorocarbon F8TAC18-PFOB emulsions previously exhibited thermal enhancement during focused ultrasound heating in ex vivo pig livers, kidneys and a laminar flow phantom. The main objectives of this study were to evaluate heating under turbulent conditions, observe perfusion effects, quantify heating in terms of acoustic absorption and model the experimental data. METHODS In this study, similar perfluorocarbon emulsions were circulated at incremental concentrations of 0.07, 0.13, 0.19 and 0.25% v:v through a percolated turbulent flow phantom, more representative of the biological tissue than a laminar flow phantom. The concentrations represent the droplet content in only the perfused fluid, rather than the droplet concentration throughout the entire cross-section. The temperature was measured with magnetic resonance thermometry, during focused ultrasound sonications of 67 W, 95% duty cycle and 33 s duration. These were used in Bioheat equation simulations to investigate in silico the thermal phenomena. The temperature change was compared with the control condition by circulating de-gassed and de-ionized water through the flow phantom without droplets. RESULTS With these 1.24 µm diameter droplets at 0.25% v:v, the acoustic absorption coefficient increased from 0.93 ± 0.05 at 0.0% v:v to 1.82 ± 0.22 m-1 at 0.25% v:v using a 0.1 mL s-1 flow rate. Without perfusion at 0.25% v:v, an increase was observed from 1.23 ± 0.07 m-1 at 0.0% v:v to 1.65 ± 0.17 m-1. CONCLUSION The results further support previously reported thermal enhancement with F8TAC18-PFOB emulsion, quantified the increased absorption at small concentration intervals, illustrated that the effects can be observed in a variety of visceral tissue models and provided a method to simulate untested scenarios.
Collapse
Affiliation(s)
- Ryan Holman
- Image Guided Interventions Laboratory, Department of Radiology, University of Geneva, Geneva, Switzerland.
| | - Pauline C Guillemin
- Image Guided Interventions Laboratory, Department of Radiology, University of Geneva, Geneva, Switzerland
| | - Orane Lorton
- Image Guided Interventions Laboratory, Department of Radiology, University of Geneva, Geneva, Switzerland
| | - Stéphane Desgranges
- Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon University, Avignon, France
| | - Christiane Contino-Pépin
- Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon University, Avignon, France
| | - Rares Salomir
- Image Guided Interventions Laboratory, Department of Radiology, University of Geneva, Geneva, Switzerland; Radiology Division, University Hospitals of Geneva, Geneva, Switzerland
| |
Collapse
|
5
|
Sadeghi-Goughari M, Han SW, Kwon HJ. Real-time monitoring of focused ultrasound therapy using intelligence-based thermography: A feasibility study. ULTRASONICS 2023; 134:107100. [PMID: 37421699 DOI: 10.1016/j.ultras.2023.107100] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 06/28/2023] [Accepted: 07/01/2023] [Indexed: 07/10/2023]
Abstract
Focused ultrasound (FUS) therapy has been widely studied for breast cancer treatment due to its potential as a fully non-invasive method to improve cosmetic and oncologic results. However, real-time imaging and monitoring of the therapeutic ultrasound delivered to the target area remain challenges for precision breast cancer therapy. The main objective of this study is to propose and evaluate a novel intelligence-based thermography (IT) method that can monitor and control FUS treatment using thermal imaging with the fusion of artificial intelligence (AI) and advanced heat transfer modeling. In the proposed method, a thermal camera is integrated into FUS system for thermal imaging of the breast surface, and an AI model is employed for the inverse analysis of the surface thermal monitoring, thereby estimating the features of the focal region. This paper presents experimental and computational studies conducted to assess the feasibility and efficiency of IT-guided FUS (ITgFUS). Tissue phantoms, designed to mimic the properties of breast tissue, were used in the experiments to investigate detectability and the impact of temperature rise at the focal region on the tissue surface. Additionally, an AI computational analysis employing an artificial neural network (ANN) and FUS simulation was carried out to provide a quantitative estimation of the temperature rise at the focal region. This estimation was based on the observed temperature profile on the breast model's surface. The results proved that the effects of temperature rise at the focused area could be detected by the thermal images acquired with thermography. Moreover, it was demonstrated that the AI analysis of the surface temperature measurement could result in near real-time monitoring of FUS by quantitative estimation of the temporal and spatial temperature rise profiles at the focal region.
Collapse
Affiliation(s)
- Moslem Sadeghi-Goughari
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
| | - Sang-Wook Han
- Department of Automotive Engineering, Shinhan University, 95 Hoam-ro, Uijeongbu, Gyeonggi-do 480-701, Republic of Korea
| | - Hyock-Ju Kwon
- Department of Mechanical and Mechatronics Engineering, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada
| |
Collapse
|
6
|
Kwizera EA, Stewart S, Mahmud MM, He X. Magnetic Nanoparticle-Mediated Heating for Biomedical Applications. JOURNAL OF HEAT TRANSFER 2022; 144:030801. [PMID: 35125512 PMCID: PMC8813031 DOI: 10.1115/1.4053007] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2021] [Revised: 11/03/2021] [Indexed: 05/17/2023]
Abstract
Magnetic nanoparticles, especially superparamagnetic nanoparticles (SPIONs), have attracted tremendous attention for various biomedical applications. Facile synthesis and functionalization together with easy control of the size and shape of SPIONS to customize their unique properties, have made it possible to develop different types of SPIONs tailored for diverse functions/applications. More recently, considerable attention has been paid to the thermal effect of SPIONs for the treatment of diseases like cancer and for nanowarming of cryopreserved/banked cells, tissues, and organs. In this mini-review, recent advances on the magnetic heating effect of SPIONs for magnetothermal therapy and enhancement of cryopreservation of cells, tissues, and organs, are discussed, together with the non-magnetic heating effect (i.e., high Intensity focused ultrasound or HIFU-activated heating) of SPIONs for cancer therapy. Furthermore, challenges facing the use of magnetic nanoparticles in these biomedical applications are presented.
Collapse
Affiliation(s)
- Elyahb Allie Kwizera
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Samantha Stewart
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Md Musavvir Mahmud
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742
| | - Xiaoming He
- Fischell Department of Bioengineering, University of Maryland, 8278 Paint Branch Drive, College Park, MD 20742; Marlene and Stewart Greenebaum Comprehensive Cancer Center, University of Maryland, Baltimore, MD 21201
| |
Collapse
|
7
|
Holman R, Lorton O, Guillemin PC, Desgranges S, Santini F, Preso DB, Farhat M, Contino-Pépin C, Salomir R. Perfluorocarbon emulsion enhances MR-ARFI displacement and temperature in vitro: Evaluating the response with MRI, NMR, and hydrophone. Front Oncol 2022; 12:1025481. [PMID: 36713528 PMCID: PMC9880467 DOI: 10.3389/fonc.2022.1025481] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Accepted: 11/18/2022] [Indexed: 01/15/2023] Open
Abstract
Sonosensitive perfluorocarbon F8TAC18-PFOB emulsion is under development to enhance heating, increase thermal contrast, and reduce treatment times during focused ultrasound tumor ablation of highly perfused tissue. The emulsion previously showed enhanced heating during ex vivo and in vitro studies. Experiments were designed to observe the response in additional scenarios by varying focused ultrasound conditions, emulsion concentrations, and surfactants. Most notably, changes in acoustic absorption were assessed with MR-ARFI. Phantoms were developed to have thermal, elastic, and relaxometry properties similar to those of ex vivo pig tissue. The phantoms were embedded with varying amounts of F8TAC18-PFOB emulsion or lecithin-PFOB emulsion, between about 0.0-0.3% v:w, in 0.05% v:w increments. MR-ARFI measurements were performed using a FLASH-ARFI-MRT sequence to obtain simultaneous displacement and temperature measurements. A Fabry-Perot hydrophone was utilized to observe the acoustic emissions. Susceptibility-weighted imaging and relaxometry mapping were performed to observe concentration-dependent effects. 19F diffusion-ordered spectroscopy NMR was used to measure the diffusion coefficient of perfluorocarbon droplets in a water emulsion. Increased displacement and temperature were observed with higher emulsion concentration. In semi-rigid MR-ARFI phantoms, a linear response was observed with low-duty cycle MR-ARFI sonications and a mono-exponential saturating response was observed with sustained sonications. The emulsifiers did not have a significant effect on acoustic absorption in semi-rigid gels. Stable cavitation might also contribute to enhanced heating.
Collapse
Affiliation(s)
- Ryan Holman
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Orane Lorton
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Pauline C Guillemin
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland
| | - Stéphane Desgranges
- Avignon Université, Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon, France
| | - Francesco Santini
- Department of Biomedical Engineering, University of Basel, Basel, Switzerland
| | - Davide Bernardo Preso
- Institute of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Mohamed Farhat
- Institute of Mechanical Engineering, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
| | - Christiane Contino-Pépin
- Avignon Université, Equipe Systèmes Amphiphiles bioactifs et Formulations Eco-compatibles, Unité Propre de Recherche et d'Innovation (UPRI), Avignon, France
| | - Rares Salomir
- Image Guided Interventions Laboratory (GR-949), Faculty of Medicine, University of Geneva, Geneva, Switzerland.,Radiology Department, University Hospitals of Geneva, Geneva, Switzerland
| |
Collapse
|
8
|
Zeng Z, Liu JB, Peng CZ. Phase-changeable nanoparticle-mediated energy conversion promotes highly efficient high-intensity focused ultrasound ablation. Curr Med Chem 2021; 29:1369-1378. [PMID: 34238143 DOI: 10.2174/0929867328666210708085110] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 04/14/2021] [Accepted: 05/09/2021] [Indexed: 11/22/2022]
Abstract
This review describes how phase-changeable nanoparticles enable highly efficient high-intensity focused ultrasound ablation (HIFU). HIFU is effective in the clinical treatment of solid malignant tumors. However, it has intrinsic disadvantages for treating some deep lesions, such as damage to surrounding normal tissues. When phase-changeable nanoparticles are used in HIFU treatment, they could serve as good synergistic agents because they are transported in the blood and permeated and accumulated effectively in tissues. HIFU's thermal effects can trigger nanoparticles to undergo a special phase transition, thus enhancing HIFU ablation efficiency. Nanoparticles can also carry anticancer agents and release them in the targeted area to achieve chemo-synergistic therapy response. Although the formation of nanoparticles is complicated and HIFU applications are still in an early stage, the potential for their use in synergy with HIFU treatment shows promising results.
Collapse
Affiliation(s)
- Zeng Zeng
- Department of Ultrasound, Zhejiang Provincial People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Ji-Bin Liu
- Department of Radiology, Thomas Jefferson University Hospital, Philadelphia, United States
| | - Cheng-Zhong Peng
- Department of Ultrasound, Zhejiang Provincial People's Hospital, Hangzhou Medical College, Hangzhou, Zhejiang, China
| |
Collapse
|
9
|
Sadeghi-Goughari M, Jeon S, Kwon HJ. Carbon nanotube-mediated high intensity focused ultrasound. NANO FUTURES 2021; 5:025002. [DOI: 10.1088/2399-1984/abfebc] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Abstract
High intensity focused ultrasound (HIFU) is emerging as a novel therapeutic technique for cancer treatment through a hyperthermal mechanism using ultrasound. However, collateral thermal damages to healthy tissue and skin burns due to the use of high levels of ultrasonic energy during HIFU treatment remain major challenges to clinical application. The main objective of the current study is to evaluate the potential of carbon nanotubes (CNTs) as effective absorption-enhancing agents for HIFU to mediate the heating process at low ultrasonic power levels, and consequently upgrade hyperthermal therapeutic effects of HIFU. An experimental study using in vitro tissue phantoms was conducted to assess the effects of CNTs on HIFU’s heating mechanism. Detailed information was extracted from the experiments for thermal analysis, including rate of absorbed energy density and temperature rise profile at the focal region. Parametric studies were carried out, revealing the effects of ultrasound parameters (ultrasonic power and driving frequency) on the performance of CNTs in various concentrations. The results indicated that CNTs significantly enhanced the thermal effect of HIFU by elevating energy absorption rate and consequential temperature rise. Moreover, it was demonstrated that an increase in ultrasonic power and driving frequency could lead to a better performance of CNTs during HIFU ablation procedures; the effects of CNTs could be further enhanced by increasing their volume concentration inside the medium.
Collapse
|