1
|
Rodríguez-Méndez BG, López-Callejas R, Mercado-Cabrera A, Peña-Eguiluz R, Valencia-Alvarado R, Betancourt-Ángeles M, Berrones-Stringel G, Jaramillo-Martínez C. Harnessing Non-Thermal Plasma to Supercharge Recovery in Abdominal Surgeries: A Pilot Study. J Clin Med 2024; 13:408. [PMID: 38256546 PMCID: PMC10816705 DOI: 10.3390/jcm13020408] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2023] [Revised: 01/04/2024] [Accepted: 01/10/2024] [Indexed: 01/24/2024] Open
Abstract
(1) Background: This study aims to evaluate the efficacy and safety of non-thermal plasma (NTP) therapy in accelerating wound healing in patients who have undergone laparoscopic and open surgeries. (2) Methods: NTP was applied using a needle-type reactor with an irradiance of 0.5 W/cm2 on the surgical wounds of fifty patients after obtaining informed consent. Three NTP treatments, each lasting three minutes, were administered hourly. (3) Results: The pilot study showed that NTP-treated surgical wounds healed completely without any signs of infection, dehiscence, pain, or itching. Notably, patients reported minimal pain after the NTP treatment. Visual assessments conducted twenty-four hours after surgery revealed no redness or fluid discharge. Comparisons with traditionally sutured wounds indicated that NTP-treated wounds healed at a rate equivalent to seven days. (4) Conclusions: The application of NTP in laparoscopic and open wounds proved safe and effective, expediting the wound healing process and eliminating clinical risks post-surgery. Significantly, NTP facilitated a healing rate within twenty-four hours, equivalent to seven days for suture-treated wounds, significantly reducing the hospitalization time to a single day. These findings highlight the potential of NTP to be a transformative approach for promoting postoperative recovery.
Collapse
Affiliation(s)
- Benjamín G. Rodríguez-Méndez
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N, La Marquesa, Ocoyoacac 52750, Mexico; (B.G.R.-M.); (R.L.-C.); (R.P.-E.); (R.V.-A.)
| | - Régulo López-Callejas
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N, La Marquesa, Ocoyoacac 52750, Mexico; (B.G.R.-M.); (R.L.-C.); (R.P.-E.); (R.V.-A.)
| | - Antonio Mercado-Cabrera
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N, La Marquesa, Ocoyoacac 52750, Mexico; (B.G.R.-M.); (R.L.-C.); (R.P.-E.); (R.V.-A.)
| | - Rosendo Peña-Eguiluz
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N, La Marquesa, Ocoyoacac 52750, Mexico; (B.G.R.-M.); (R.L.-C.); (R.P.-E.); (R.V.-A.)
| | - Raúl Valencia-Alvarado
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México-Toluca S/N, La Marquesa, Ocoyoacac 52750, Mexico; (B.G.R.-M.); (R.L.-C.); (R.P.-E.); (R.V.-A.)
| | - Mario Betancourt-Ángeles
- Medical Center ISSEMyM Toluca, Av. Baja velocidad 284 km. 57.5, San Jerónimo Chicahualco, Metepec 52170, Mexico
| | - Guillermo Berrones-Stringel
- Medical Center ISSEMyM Toluca, Av. Baja velocidad 284 km. 57.5, San Jerónimo Chicahualco, Metepec 52170, Mexico
| | - César Jaramillo-Martínez
- Medical Center ISSEMyM Toluca, Av. Baja velocidad 284 km. 57.5, San Jerónimo Chicahualco, Metepec 52170, Mexico
| |
Collapse
|
2
|
Arguello-Sánchez R, López-Callejas R, Rodríguez-Méndez BG, Scougall-Vilchis R, Velázquez-Enríquez U, Mercado-Cabrera A, Peña-Eguiluz R, Valencia-Alvarado R, Medina-Solís CE. Innovative Curved-Tip Reactor for Non-Thermal Plasma and Plasma-Treated Water Generation: Synergistic Impact Comparison with Sodium Hypochlorite in Dental Root Canal Disinfection. MATERIALS (BASEL, SWITZERLAND) 2023; 16:7204. [PMID: 38005133 PMCID: PMC10672626 DOI: 10.3390/ma16227204] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2023] [Revised: 11/13/2023] [Accepted: 11/15/2023] [Indexed: 11/26/2023]
Abstract
Non-thermal plasmas (NTPs), known as cold atmospheric plasmas (CAPs), hold great potential for diverse medical applications, including dentistry. However, traditional linear and rigid dielectric barrier discharge reactors used for NTP generation encounter limitations in accessing oral cavities and root canals. To address this issue, we have developed an innovative NTP reactor featuring an angled end for improved accessibility. The central copper electrode, with a 0.59 mm diameter and adjustable length for desired angulation, is coated with zircon powder (ZrSiO4) to ensure stable NTP generation. This central electrode is housed within a stainless steel tube (3 mm internal diameter, 8 mm external diameter, and 100 mm length) with a 27° angle at one end, making it ergonomically suitable for oral applications. NTP generation involves polarizing the reactor electrodes with 13.56 MHz radio frequency signals, using helium gas as a working medium. We introduce plasma-treated water (PTW) as an adjunctive therapy to enhance biofilm eradication within root canals. A synergistic approach combining NTP and PTW is employed and compared to the gold standard (sodium hypochlorite, NaOCl), effectively neutralizing Enterococcus faecalis bacteria, even in scenarios involving biofilms. Moreover, applying NTP in both gaseous and liquid environments successfully achieves bacterial inactivation at varying treatment durations, demonstrating the device's suitability for medical use in treating root canal biofilms. The proposed NTP reactor, characterized by its innovative design, offers a practical and specific approach to plasma treatment in dental applications. It holds promise in combatting bacterial infections in root canals and oral cavities.
Collapse
Affiliation(s)
- Raúl Arguello-Sánchez
- Dental Reseach Center and Advanced Studies "Dr. Keisaburo Miyata", School of Dentistry, Autonomous University of Mexico State, Av. Paseo Tollocan, 13 Universidad, Toluca de Lerdo 50130, Mexico
| | - Régulo López-Callejas
- Department of Physics, National Institute for Nuclear Research, Carretera Mexico-Toluca S/N, Ocoyoacac 52750, Mexico
| | | | - Rogelio Scougall-Vilchis
- Dental Reseach Center and Advanced Studies "Dr. Keisaburo Miyata", School of Dentistry, Autonomous University of Mexico State, Av. Paseo Tollocan, 13 Universidad, Toluca de Lerdo 50130, Mexico
| | - Ulises Velázquez-Enríquez
- Dental Reseach Center and Advanced Studies "Dr. Keisaburo Miyata", School of Dentistry, Autonomous University of Mexico State, Av. Paseo Tollocan, 13 Universidad, Toluca de Lerdo 50130, Mexico
| | - Antonio Mercado-Cabrera
- Department of Physics, National Institute for Nuclear Research, Carretera Mexico-Toluca S/N, Ocoyoacac 52750, Mexico
| | - Rosendo Peña-Eguiluz
- Department of Physics, National Institute for Nuclear Research, Carretera Mexico-Toluca S/N, Ocoyoacac 52750, Mexico
| | - Raúl Valencia-Alvarado
- Department of Physics, National Institute for Nuclear Research, Carretera Mexico-Toluca S/N, Ocoyoacac 52750, Mexico
| | - Carlo Eduardo Medina-Solís
- Dental Reseach Center and Advanced Studies "Dr. Keisaburo Miyata", School of Dentistry, Autonomous University of Mexico State, Av. Paseo Tollocan, 13 Universidad, Toluca de Lerdo 50130, Mexico
- Dentistry Academic Area of the Health Sciences Institute, Autonomous University of Hidalgo State, Exhacienda de la Concepción S/N Carretera Actopan-Tilcuautla, San Agustin Tlaxiaca 42160, Mexico
| |
Collapse
|
3
|
Ibáñez-Mancera NG, López-Callejas R, Toral-Rizo VH, Rodríguez-Méndez BG, Lara-Carrillo E, Peña-Eguiluz R, do Amaral RC, Mercado-Cabrera A, Valencia-Alvarado R. Healing of Recurrent Aphthous Stomatitis by Non-Thermal Plasma: Pilot Study. Biomedicines 2023; 11:biomedicines11010167. [PMID: 36672674 PMCID: PMC9856114 DOI: 10.3390/biomedicines11010167] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 12/29/2022] [Accepted: 12/31/2022] [Indexed: 01/11/2023] Open
Abstract
Recurrent aphthous stomatitis (RAS) is a common disease in the oral cavity characterized by recurrent ulcers (RU). Usually, these cause acute pain without definitive treatment. The present study determines the efficacy of non-thermal plasma (NTP) for treating RU. NTP is applied to the patient's RU using a radiofrequency generator connected to a point reactor. The power density applied to the ulcer is 0.50 W/cm2, less than 4 W/cm2, which is the maximum value without biological risk. Each patient received two treatments of three minutes each and spaced 60 min apart at a distance of 5 mm from the RU. From a sample of 30 ulcers in patients treated for RU with an average age of 37 years, they stated that the pain decreased considerably and without the need for ingestion of analgesics and antibiotics. Regeneration took place in an average of three days. The NTP proved to be an excellent therapeutic alternative for the treatment of RU since it has a rapid effect of reducing pain and inflammation, as well as adequate tissue regeneration.
Collapse
Affiliation(s)
- Norma Guadalupe Ibáñez-Mancera
- Interdisciplinary Center for Health Sciences CICS-UST, Instituto Politécnico Nacional, Av. Luis Enrique Erro S/N, Unidad Profesional Adolfo López Mateos, Zacatenco 07738, Mexico
| | - Régulo López-Callejas
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México Toluca S/N, Ocoyoacac 52750, Mexico
| | - Víctor Hugo Toral-Rizo
- Orocenter Clinic, Facultad de Odontología, Universidad Autónoma del Estado de México, Av. Paseo Tollocan esq. Jesús Carranza, Colonia Universidad, Toluca de Lerdo 50130, Mexico
| | - Benjamín Gonzalo Rodríguez-Méndez
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México Toluca S/N, Ocoyoacac 52750, Mexico
- Correspondence:
| | - Edith Lara-Carrillo
- Orocenter Clinic, Facultad de Odontología, Universidad Autónoma del Estado de México, Av. Paseo Tollocan esq. Jesús Carranza, Colonia Universidad, Toluca de Lerdo 50130, Mexico
| | - Rosendo Peña-Eguiluz
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México Toluca S/N, Ocoyoacac 52750, Mexico
| | | | - Antonio Mercado-Cabrera
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México Toluca S/N, Ocoyoacac 52750, Mexico
| | - Raúl Valencia-Alvarado
- Plasma Physics Laboratory, Instituto Nacional de Investigaciones Nucleares, Carretera México Toluca S/N, Ocoyoacac 52750, Mexico
| |
Collapse
|
4
|
Peña Eguiluz R, López-Callejas R, González-Arciniega E, Rodríguez-Méndez BG, Mercado-Cabrera A, Guakil-Haber A, Kuri García A, Espinosa Mancilla AE, Valencia-Alvarado R. Non-thermal plasma wound healing after removal of a neck tumor in a patient with HIV: A case report. OTOLARYNGOLOGY CASE REPORTS 2022. [DOI: 10.1016/j.xocr.2021.100391] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
|