1
|
Xu H, Haider W, Aziz MZ, Sun Y, Yu X. Transforming Motor Imagery Analysis: A Novel EEG Classification Framework Using AtSiftNet Method. SENSORS (BASEL, SWITZERLAND) 2024; 24:6466. [PMID: 39409506 PMCID: PMC11479282 DOI: 10.3390/s24196466] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/09/2024] [Revised: 09/28/2024] [Accepted: 09/29/2024] [Indexed: 10/20/2024]
Abstract
This paper presents an innovative approach for the Feature Extraction method using Self-Attention, incorporating various Feature Selection techniques known as the AtSiftNet method to enhance the classification performance of motor imaginary activities using electrophotography (EEG) signals. Initially, the EEG signals were sorted and then denoised using multiscale principal component analysis to obtain clean EEG signals. However, we also conducted a non-denoised experiment. Subsequently, the clean EEG signals underwent the Self-Attention feature extraction method to compute the features of each trial (i.e., 350×18). The best 1 or 15 features were then extracted through eight different feature selection techniques. Finally, five different machine learning and neural network classification models were employed to calculate the accuracy, sensitivity, and specificity of this approach. The BCI competition III dataset IV-a was utilized for all experiments, encompassing the datasets of five volunteers who participated in the competition. The experiment findings reveal that the average accuracy of classification is highest among ReliefF (i.e., 99.946%), Mutual Information (i.e., 98.902%), Independent Component Analysis (i.e., 99.62%), and Principal Component Analysis (i.e., 98.884%) for both 1 and 15 best-selected features from each trial. These accuracies were obtained for motor imagery using a Support Vector Machine (SVM) as a classifier. In addition, five-fold validation was performed in this paper to assess the fair performance estimation and robustness of the model. The average accuracy obtained through five-fold validation is 99.89%. The experiments' findings indicate that the suggested framework provides a resilient biomarker with minimal computational complexity, making it a suitable choice for advancing Motor Imagery Brain-Computer Interfaces (BCI).
Collapse
Affiliation(s)
- Haiqin Xu
- College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China; (H.X.); (Y.S.)
| | - Waseem Haider
- School of Automation, Northwestern Polytechnical University, Xi’an 710072, China; (W.H.); (M.Z.A.)
| | - Muhammad Zulkifal Aziz
- School of Automation, Northwestern Polytechnical University, Xi’an 710072, China; (W.H.); (M.Z.A.)
| | - Youchao Sun
- College of Civil Aviation, Nanjing University of Aeronautics and Astronautics, Nanjing 211106, China; (H.X.); (Y.S.)
| | - Xiaojun Yu
- School of Automation, Northwestern Polytechnical University, Xi’an 710072, China; (W.H.); (M.Z.A.)
| |
Collapse
|
2
|
Li R, Zhang Y, Fan G, Li Z, Li J, Fan S, Lou C, Liu X. Design and implementation of high sampling rate and multichannel wireless recorder for EEG monitoring and SSVEP response detection. Front Neurosci 2023; 17:1193950. [PMID: 37457014 PMCID: PMC10339741 DOI: 10.3389/fnins.2023.1193950] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Accepted: 05/30/2023] [Indexed: 07/18/2023] Open
Abstract
Introduction The collection and process of human brain activity signals play an essential role in developing brain-computer interface (BCI) systems. A portable electroencephalogram (EEG) device has become an important tool for monitoring brain activity and diagnosing mental diseases. However, the miniaturization, portability, and scalability of EEG recorder are the current bottleneck in the research and application of BCI. Methods For scalp EEG and other applications, the current study designs a 32-channel EEG recorder with a sampling rate up to 30 kHz and 16-bit accuracy, which can meet both the demands of scalp and intracranial EEG signal recording. A fully integrated electrophysiology microchip RHS2116 controlled by FPGA is employed to build the EEG recorder, and the design meets the requirements of high sampling rate, high transmission rate and channel extensive. Results The experimental results show that the developed EEG recorder provides a maximum 30 kHz sampling rate and 58 Mbps wireless transmission rate. The electrophysiological experiments were performed on scalp and intracranial EEG collection. An inflatable helmet with adjustable contact impedance was designed, and the pressurization can improve the SNR by approximately 4 times, the average accuracy of steady-state visual evoked potential (SSVEP) was 93.12%. Animal experiments were also performed on rats, and spike activity was captured successfully. Conclusion The designed multichannel wireless EEG collection system is simple and comfort, the helmet-EEG recorder can capture the bioelectric signals without noticeable interference, and it has high measurement performance and great potential for practical application in BCI systems.
Collapse
Affiliation(s)
- Ruikai Li
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
- Information Center, The Affiliated Hospital of Hebei University, Baoding, China
| | - Yixing Zhang
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Guangwei Fan
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Ziteng Li
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Jun Li
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Shiyong Fan
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Cunguang Lou
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| | - Xiuling Liu
- The College of Electronic Information Engineering and the Hebei Key Laboratory of Digital Medical Engineering, Hebei University, Baoding, China
| |
Collapse
|
3
|
Saibene A, Caglioni M, Corchs S, Gasparini F. EEG-Based BCIs on Motor Imagery Paradigm Using Wearable Technologies: A Systematic Review. SENSORS (BASEL, SWITZERLAND) 2023; 23:2798. [PMID: 36905004 PMCID: PMC10007053 DOI: 10.3390/s23052798] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2023] [Revised: 02/21/2023] [Accepted: 02/28/2023] [Indexed: 06/18/2023]
Abstract
In recent decades, the automatic recognition and interpretation of brain waves acquired by electroencephalographic (EEG) technologies have undergone remarkable growth, leading to a consequent rapid development of brain-computer interfaces (BCIs). EEG-based BCIs are non-invasive systems that allow communication between a human being and an external device interpreting brain activity directly. Thanks to the advances in neurotechnologies, and especially in the field of wearable devices, BCIs are now also employed outside medical and clinical applications. Within this context, this paper proposes a systematic review of EEG-based BCIs, focusing on one of the most promising paradigms based on motor imagery (MI) and limiting the analysis to applications that adopt wearable devices. This review aims to evaluate the maturity levels of these systems, both from the technological and computational points of view. The selection of papers has been performed following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA), leading to 84 publications considered in the last ten years (from 2012 to 2022). Besides technological and computational aspects, this review also aims to systematically list experimental paradigms and available datasets in order to identify benchmarks and guidelines for the development of new applications and computational models.
Collapse
Affiliation(s)
- Aurora Saibene
- Department of Informatics, Systems and Communication, University of Milano-Bicocca, Viale Sarca 336, 20126 Milano, Italy
- NeuroMI, Milan Center for Neuroscience, Piazza dell’Ateneo Nuovo 1, 20126 Milano, Italy
| | - Mirko Caglioni
- Department of Informatics, Systems and Communication, University of Milano-Bicocca, Viale Sarca 336, 20126 Milano, Italy
| | - Silvia Corchs
- NeuroMI, Milan Center for Neuroscience, Piazza dell’Ateneo Nuovo 1, 20126 Milano, Italy
- Department of Theoretical and Applied Sciences, University of Insubria, Via J. H. Dunant 3, 21100 Varese, Italy
| | - Francesca Gasparini
- Department of Informatics, Systems and Communication, University of Milano-Bicocca, Viale Sarca 336, 20126 Milano, Italy
- NeuroMI, Milan Center for Neuroscience, Piazza dell’Ateneo Nuovo 1, 20126 Milano, Italy
| |
Collapse
|
4
|
Sun H, Li C, Zhang H. Design of virtual BCI channels based on informer. Front Hum Neurosci 2023; 17:1150316. [PMID: 37169016 PMCID: PMC10165084 DOI: 10.3389/fnhum.2023.1150316] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2023] [Accepted: 04/07/2023] [Indexed: 05/13/2023] Open
Abstract
The precision and reliability of electroencephalogram (EEG) data are essential for the effective functioning of a brain-computer interface (BCI). As the number of BCI acquisition channels increases, more EEG information can be gathered. However, having too many channels will reduce the practicability of the BCI system, raise the likelihood of poor-quality channels, and lead to information misinterpretation. These issues pose challenges to the advancement of BCI systems. Determining the optimal configuration of BCI acquisition channels can minimize the number of channels utilized, but it is challenging to maintain the original operating system and accommodate individual variations in channel layout. To address these concerns, this study introduces the EEG-completion-informer (EC-informer), which is based on the Informer architecture known for its effectiveness in time-series problems. By providing input from four BCI acquisition channels, the EC-informer can generate several virtual acquisition channels to extract additional EEG information for analysis. This approach allows for the direct inheritance of the original model, significantly reducing researchers' workload. Moreover, EC-informers demonstrate strong performance in damaged channel repair and poor channel identification. Using the Informer as a foundation, the study proposes the EC-informer, tailored to BCI requirements and demanding only a small number of training samples. This approach eliminates the need for extensive computing units to train an efficient, lightweight model while preserving comprehensive information about target channels. The study also confirms that the proposed model can be transferred to other operators with minimal loss, exhibiting robust applicability. The EC-informer's features enable original BCI devices to adapt to a broader range of classification algorithms and relax the operational requirements of BCI devices, which could facilitate the promotion of the use of BCI devices in daily life.
Collapse
|
5
|
Sadiq MT, Yu X, Yuan Z, Aziz MZ, Siuly S, Ding W. A Matrix Determinant Feature Extraction Approach for Decoding Motor and Mental Imagery EEG in Subject Specific Tasks. IEEE Trans Cogn Dev Syst 2020. [DOI: 10.1109/tcds.2020.3040438] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
6
|
Zhang Y, Zhang X, Sun H, Fan Z, Zhong X. Portable brain-computer interface based on novel convolutional neural network. Comput Biol Med 2019; 107:248-256. [PMID: 30856388 DOI: 10.1016/j.compbiomed.2019.02.023] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Revised: 02/26/2019] [Accepted: 02/26/2019] [Indexed: 11/17/2022]
Abstract
Electroencephalography (EEG) is a powerful, noninvasive tool that provides a high temporal resolution to directly reflect brain activities. Conventional electrodes require skin preparation and the use of conductive gels, while subjects must wear uncomfortable EEG hats. These procedures usually create a challenge for subjects. In the present study, we propose a portable EEG signal acquisition system. This study consists of two main parts: 1) A novel, portable dry-electrode and wireless brain-computer interface is designed. The EEG signal acquisition board is based on 24 bit, analog-to-digital converters chip and wireless microprocessor unit. The wireless portable brain computer interface device acquires an EEG signal comfortably, and the EEG signals are transmitted to a personal computer via Bluetooth. 2) A convolutional neural network (CNN) classification algorithm is implemented to classify the motor imagery (MI) experiment using novel feature 3-dimension input. The time dimension was reshaped to represent the first and second dimension, and the frequency band was used as the third dimension. Specifically, frequency domain representations of EEG signals obtained via wavelet package decomposition (WPD) are obtained to train CNN. The classification performance in terms of the value of kappa is 0.564 for the proposed method. The t-test results show that the performance improvement of CNN over other selected state-of-the-art methods is statistically significant. Our results show that the proposed design is reliable in measuring EEG signals, and the 3D CNN provides better classification performance than other method for MI experiments.
Collapse
Affiliation(s)
- Yu Zhang
- Department of Electronic Science and Engineering, Southeast University, Nanjing, 210096, China.
| | - Xiong Zhang
- Department of Electronic Science and Engineering, Southeast University, Nanjing, 210096, China.
| | - Han Sun
- Department of Electronic Science and Engineering, Southeast University, Nanjing, 210096, China.
| | - Zhaowen Fan
- Department of Electronic Science and Engineering, Southeast University, Nanjing, 210096, China.
| | - Xuefei Zhong
- Department of Electronic Science and Engineering, Southeast University, Nanjing, 210096, China.
| |
Collapse
|