Antoniou A, Nikolaou A, Evripidou N, Georgiou A, Filippou A, Zinonos V, Giannakou M, Chrysanthou A, Ioannides C, Damianou C. Phantom-based assessment of motion and needle targeting accuracy of robotic devices for magnetic resonance imaging-guided needle biopsy. Int J Med Robot 2023; 19:e2526. [PMID: 37165718 DOI: 10.1002/rcs.2526] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2022] [Revised: 04/18/2023] [Accepted: 04/24/2023] [Indexed: 05/12/2023]
Abstract
BACKGROUND The current study proposes simple methods for assessing the performance of robotic devices intended for Magnetic Resonance Imaging (MRI)-guided needle biopsy. METHODS In-house made agar-based breast phantoms containing biopsy targets served as the main tool in the evaluation process of an MRI compatible positioning device comprising a needle navigator. The motion accuracy of mechanical stages was assessed by calliper measurements. Laboratory evaluation of needle targeting included a repeatability phantom test and a laser-based method. The accuracy and repeatability of needle targeting was also assessed by MRI. RESULTS The maximum error of linear motion for steps up to 10 mm was 0.1 mm. Needle navigation relative to the phantom and alignment with the various biopsy targets were performed successfully in both the laboratory and MRI settings. The proposed biopsy phantoms offered tissue-like signal in MRI and good haptic feedback during needle insertion. CONCLUSIONS The proposed methods could be valuable in the process of validating the accuracy of MRI-guided biopsy robotic devices in both laboratory and real environments.
Collapse
Affiliation(s)
- Anastasia Antoniou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Anastasia Nikolaou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Nikolas Evripidou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Andreas Georgiou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Antria Filippou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | - Vasiliki Zinonos
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| | | | - Antreas Chrysanthou
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Cleanthis Ioannides
- Department of Interventional Radiology, German Oncology Center, Limassol, Cyprus
| | - Christakis Damianou
- Department of Electrical Engineering, Computer Engineering, and Informatics, Cyprus University of Technology, Limassol, Cyprus
| |
Collapse
|
2
|
Ren W, Deán-Ben XL, Skachokova Z, Augath MA, Ni R, Chen Z, Razansky D. Monitoring mouse brain perfusion with hybrid magnetic resonance optoacoustic tomography. BIOMEDICAL OPTICS EXPRESS 2023; 14:1192-1204. [PMID: 36950237 PMCID: PMC10026577 DOI: 10.1364/boe.482205] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2022] [Revised: 01/10/2023] [Accepted: 01/10/2023] [Indexed: 06/18/2023]
Abstract
Progress in brain research critically depends on the development of next-generation multi-modal imaging tools capable of capturing transient functional events and multiplexed contrasts noninvasively and concurrently, thus enabling a holistic view of dynamic events in vivo. Here we report on a hybrid magnetic resonance and optoacoustic tomography (MROT) system for murine brain imaging, which incorporates an MR-compatible spherical matrix array transducer and fiber-based light illumination into a 9.4 T small animal scanner. An optimized radiofrequency coil has further been devised for whole-brain interrogation. System's utility is showcased by acquiring complementary angiographic and soft tissue anatomical contrast along with simultaneous dual-modality visualization of contrast agent dynamics in vivo.
Collapse
Affiliation(s)
- Wuwei Ren
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich 8093, Switzerland
- Present address: School of Information Science and Technology, ShanghaiTech University, Shanghai 201210, China
- equal contribution
| | - Xosé Luís Deán-Ben
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich 8093, Switzerland
- equal contribution
| | - Zhiva Skachokova
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
| | - Mark-Aurel Augath
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich 8093, Switzerland
| | - Ruiqing Ni
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Zurich Neuroscience Center, University of Zurich and ETH Zurich, Zurich 8093, Switzerland
- Institute for Regenerative Medicine, Faculty of Medicine, University of Zurich, Zurich 8952, Switzerland
| | - Zhenyue Chen
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich 8093, Switzerland
| | - Daniel Razansky
- Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich 8052, Switzerland
- Institute for Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Zurich 8093, Switzerland
- Zurich Neuroscience Center, University of Zurich and ETH Zurich, Zurich 8093, Switzerland
| |
Collapse
|
3
|
Sound Velocity Estimation and Beamform Correction by Simultaneous Multimodality Imaging with Ultrasound and Magnetic Resonance. APPLIED SCIENCES-BASEL 2018. [DOI: 10.3390/app8112133] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Since the sound velocity for medical ultrasound imaging is usually set at 1540 m/s, the ultrasound imaging of a patient with a thick layer of subcutaneous fat is degraded due to variations in the sound velocity. This study proposes a method of compensating for image degradation to correct beamforming. This method uses the sound velocity distribution measured in simultaneous ultrasound (US) and magnetic resonance (MR) imaging. Experiments involving simultaneous imaging of an abdominal phantom and a human neck were conducted to evaluate the feasibility of the proposed method using ultrasound imaging equipment and a 1.5 T MRI scanner. MR-visible fiducial markers were attached to an ultrasound probe that was developed for use in an MRI gantry. The sound velocity distribution was calculated based on the MRI cross section, which was estimated as a corresponding cross section of US imaging using the location of fiducial markers in MRI coordinates. The results of the abdominal phantom and neck imaging indicated that the estimated values of sound velocity distribution allowed beamform correction that yielded compensated images. The feasibility of the proposed method was then evaluated in terms of quantitative improvements in the spatial resolution and signal-to-noise ratio.
Collapse
|
4
|
Crake C, Brinker ST, Coviello CM, Livingstone MS, McDannold NJ. A dual-mode hemispherical sparse array for 3D passive acoustic mapping and skull localization within a clinical MRI guided focused ultrasound device. Phys Med Biol 2018; 63:065008. [PMID: 29459494 DOI: 10.1088/1361-6560/aab0aa] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Previous work has demonstrated that passive acoustic imaging may be used alongside MRI for monitoring of focused ultrasound therapy. However, past implementations have generally made use of either linear arrays originally designed for diagnostic imaging or custom narrowband arrays specific to in-house therapeutic transducer designs, neither of which is fully compatible with clinical MR-guided focused ultrasound (MRgFUS) devices. Here we have designed an array which is suitable for use within an FDA-approved MR-guided transcranial focused ultrasound device, within the bore of a 3 Tesla clinical MRI scanner. The array is constructed from 5 × 0.4 mm piezoceramic disc elements arranged in pseudorandom fashion on a low-profile laser-cut acrylic frame designed to fit between the therapeutic elements of a 230 kHz InSightec ExAblate 4000 transducer. By exploiting thickness and radial resonance modes of the piezo discs the array is capable of both B-mode imaging at 5 MHz for skull localization, as well as passive reception at the second harmonic of the therapy array for detection of cavitation and 3D passive acoustic imaging. In active mode, the array was able to perform B-mode imaging of a human skull, showing the outer skull surface with good qualitative agreement with MR imaging. Extension to 3D showed the array was able to locate the skull within ±2 mm/2° of reference points derived from MRI, which could potentially allow registration of a patient to the therapy system without the expense of real-time MRI. In passive mode, the array was able to resolve a point source in 3D within a ±10 mm region about each axis from the focus, detect cavitation (SNR ~ 12 dB) at burst lengths from 10 cycles to continuous wave, and produce 3D acoustic maps in a flow phantom. Finally, the array was used to detect and map cavitation associated with microbubble activity in the brain in nonhuman primates.
Collapse
Affiliation(s)
- Calum Crake
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 221 Longwood Avenue, Boston, MA 02115, United States of America
| | | | | | | | | |
Collapse
|
5
|
Guo R, Lu G, Qin B, Fei B. Ultrasound Imaging Technologies for Breast Cancer Detection and Management: A Review. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:37-70. [PMID: 29107353 PMCID: PMC6169997 DOI: 10.1016/j.ultrasmedbio.2017.09.012] [Citation(s) in RCA: 241] [Impact Index Per Article: 34.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2017] [Revised: 09/12/2017] [Accepted: 09/13/2017] [Indexed: 05/25/2023]
Abstract
Ultrasound imaging is a commonly used modality for breast cancer detection and diagnosis. In this review, we summarize ultrasound imaging technologies and their clinical applications for the management of breast cancer patients. The technologies include ultrasound elastography, contrast-enhanced ultrasound, 3-D ultrasound, automatic breast ultrasound and computer-aided detection of breast ultrasound. We summarize the study results seen in the literature and discuss their future directions. We also provide a review of ultrasound-guided, breast biopsy and the fusion of ultrasound with other imaging modalities, especially magnetic resonance imaging (MRI). For comparison, we also discuss the diagnostic performance of mammography, MRI, positron emission tomography and computed tomography for breast cancer diagnosis at the end of this review. New ultrasound imaging techniques, ultrasound-guided biopsy and the fusion of ultrasound with other modalities provide important tools for the management of breast patients.
Collapse
Affiliation(s)
- Rongrong Guo
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA; Department of Ultrasound, Shanxi Provincial Cancer Hospital, Taiyuan, Shanxi, China
| | - Guolan Lu
- The Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA
| | - Binjie Qin
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Baowei Fei
- Department of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, Georgia, USA; The Wallace H. Coulter Department of Biomedical Engineering, Emory University and Georgia Institute of Technology, Atlanta, Georgia, USA; Department of Mathematics and Computer Science, Emory College of Emory University, Atlanta, Georgia, USA; Winship Cancer Institute of Emory University, Atlanta, Georgia, USA.
| |
Collapse
|
6
|
Crowe LA, Manasseh G, Chmielewski A, Hachulla AL, Speicher D, Greiser A, Muller H, de Perrot T, Vallee JP, Salomir R. Spatially Resolved MR-Compatible Doppler Ultrasound: Proof of Concept for Triggering of Diagnostic Quality Cardiovascular MRI for Function and Flow Quantification at 3T. IEEE Trans Biomed Eng 2017; 65:294-306. [PMID: 29053451 DOI: 10.1109/tbme.2017.2764111] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
OBJECTIVE We demonstrate the use of a magnetic-resonance (MR)-compatible ultrasound (US) imaging probe using spatially resolved Doppler for diagnostic quality cardiovascular MR imaging (MRI) as an initial step toward hybrid US/MR fetal imaging. METHODS A newly developed technology for a dedicated MR-compatible phased array ultrasound-imaging probe acquired pulsed color Doppler carotid images, which were converted in near-real time to a trigger signal for cardiac cine and flow quantification MRI. Ultrasound and MR data acquired simultaneously were interference free. Conventional electrocardiogram (ECG) and the proposed spatially resolved Doppler triggering were compared in 10 healthy volunteers. A synthetic "false-triggered" image was retrospectively processed using metric optimized gating (MOG). Images were scored by expert readers, and sharpness, cardiac function and aortic flow were quantified. Four-dimensional (4-D) flow (two volunteers) showed feasibility of Doppler triggering over a long acquisition time. RESULTS Imaging modalities were compatible. US probe positioning was stable and comfortable. Image quality scores and quantified sharpness were statistically equal for Doppler- and ECG-triggering (p ). ECG-, Doppler-triggered, and MOG ejection fractions were equivalent (p ), with false-triggered values significantly lower (p < 0.0005). Aortic flow showed no difference between ECG- and Doppler-triggered and MOG (p > 0.05). 4-D flow quantification gave consistent results between ECG and Doppler triggering. CONCLUSION We report interference-free pulsed color Doppler ultrasound during MR data acquisition. Cardiovascular MRI of diagnostic quality was successfully obtained with pulsed color Doppler triggering. SIGNIFICANCE The hardware platform could further enable advanced free-breathing cardiac imaging. Doppler ultrasound triggering is applicable where ECG is compromised due to pathology or interference at higher magnetic fields, and where direct ECG is impossible, i.e., fetal imaging.
Collapse
|
7
|
Ma C, Long Z, Lanners DM, Tradup DJ, Brunnquell CL, Felmlee JP, Woodrum DA, Watson RE, Hangiandreou NJ, Gorny KR. Protocol for testing suitability of compact US imaging systems for use inside MRI suites, and application to one commercial US system. Biomed Phys Eng Express 2016. [DOI: 10.1088/2057-1976/2/4/047003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
8
|
Zaidi H, Thompson C. Evolution and Developments in Instrumentation for Positron Emission Mammography. PET Clin 2016; 4:317-27. [PMID: 27157301 DOI: 10.1016/j.cpet.2009.12.002] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Molecular imaging using high-resolution PET instrumentation is now playing a pivotal role in basic and clinical research. The development of optimized detection geometries combined with high-performance detector technologies and compact designs of PET tomographs have become the goal of active research groups in academic and corporate settings. Significant progress has been achieved in the design of commercial PET instrumentation in the last decade allowing a spatial resolution of about 4 to 6 mm to be reached for whole-body imaging, about 2.4 mm for PET cameras dedicated for brain imaging, and submillimeter resolution for female breast, prostate, and small-animal imaging. In particular, significant progress has been made in the design of dedicated positron emission mammography (PEM) units. The initial concept suggested in 1993 consisted of placing 2 planar detectors capable of detecting the 511-keV annihilation photons in a conventional mammography unit. Since that time, many different design paths have been pursued and it will be interesting to see which technologies become the most successful in the future. This paper discusses recent advances in PEM instrumentation and the advantages and challenges of dedicated standalone and dual-modality imaging systems. Future opportunities and the challenges facing the adoption of PEM imaging instrumentation and its role in clinical and research settings are also addressed.
Collapse
Affiliation(s)
- Habib Zaidi
- Division of Nuclear Medicine, Geneva University Hospital, CH-1211 Geneva, Switzerland
| | - Christopher Thompson
- Department of Medical Physics, Montreal Neurological Institute, McGill University, Montreal, QC H3A 2B4, Canada
| |
Collapse
|
9
|
Loeve AJ, Al-Issawi J, Fernandez-Gutiérrez F, Langø T, Strehlow J, Haase S, Matzko M, Napoli A, Melzer A, Dankelman J. Workflow and intervention times of MR-guided focused ultrasound – Predicting the impact of new techniques. J Biomed Inform 2016; 60:38-48. [DOI: 10.1016/j.jbi.2016.01.001] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2015] [Revised: 12/28/2015] [Accepted: 01/01/2016] [Indexed: 12/30/2022]
|
10
|
Speicher D, Bartscherer T, Becker F, Jenne J, Mrosk K, Degel C, Günther M, Tretbar S. MRI Compatible Ultrasound Transducers for Simultaneous Acquisition of Coregistered Ultrasound to MRI Data. ACTA ACUST UNITED AC 2015. [DOI: 10.1016/j.phpro.2015.08.209] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
11
|
Kording F, Schoennagel B, Lund G, Ueberle F, Jung C, Adam G, Yamamura J. Doppler ultrasound compared with electrocardiogram and pulse oximetry cardiac triggering: A pilot study. Magn Reson Med 2014; 74:1257-65. [DOI: 10.1002/mrm.25502] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2014] [Revised: 10/01/2014] [Accepted: 10/06/2014] [Indexed: 11/07/2022]
Affiliation(s)
- Fabian Kording
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| | - Bjoern Schoennagel
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| | - Gunnar Lund
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| | | | - Caroline Jung
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| | - Gerhard Adam
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| | - Jin Yamamura
- University Medical Centre Hamburg-Eppendorf, Centre for Radiology and Endoscopy, Department of Diagnostic and Interventional Radiology; Germany
| |
Collapse
|
12
|
Sherwood V, Civale J, Rivens I, Collins DJ, Leach MO, ter Haar GR. Development of a hybrid magnetic resonance and ultrasound imaging system. BIOMED RESEARCH INTERNATIONAL 2014; 2014:914347. [PMID: 25177702 PMCID: PMC4142177 DOI: 10.1155/2014/914347] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2014] [Revised: 07/11/2014] [Accepted: 07/16/2014] [Indexed: 12/29/2022]
Abstract
A system which allows magnetic resonance (MR) and ultrasound (US) image data to be acquired simultaneously has been developed. B-mode and Doppler US were performed inside the bore of a clinical 1.5 T MRI scanner using a clinical 1-4 MHz US transducer with an 8-metre cable. Susceptibility artefacts and RF noise were introduced into MR images by the US imaging system. RF noise was minimised by using aluminium foil to shield the transducer. A study of MR and B-mode US image signal-to-noise ratio (SNR) as a function of transducer-phantom separation was performed using a gel phantom. This revealed that a 4 cm separation between the phantom surface and the transducer was sufficient to minimise the effect of the susceptibility artefact in MR images. MR-US imaging was demonstrated in vivo with the aid of a 2 mm VeroWhite 3D-printed spherical target placed over the thigh muscle of a rat. The target allowed single-point registration of MR and US images in the axial plane to be performed. The system was subsequently demonstrated as a tool for the targeting and visualisation of high intensity focused ultrasound exposure in the rat thigh muscle.
Collapse
Affiliation(s)
- Victoria Sherwood
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| | - John Civale
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| | - Ian Rivens
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| | - David J. Collins
- Department of Clinical Magnetic Resonance, CRUK and EPSRC Cancer Imaging Centre, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| | - Martin O. Leach
- Department of Clinical Magnetic Resonance, CRUK and EPSRC Cancer Imaging Centre, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| | - Gail R. ter Haar
- Division of Radiotherapy and Imaging, The Institute of Cancer Research and The Royal Marsden NHS Foundation Trust, 123 Old Brompton Road, London SW7 3RP, UK
| |
Collapse
|
13
|
Vijayan S, Klein S, Hofstad EF, Lindseth F, Ystgaard B, Langø T. Motion tracking in the liver: Validation of a method based on 4D ultrasound using a nonrigid registration technique. Med Phys 2014; 41:082903. [DOI: 10.1118/1.4890091] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023] Open
|
14
|
Yang B, Roys S, Tan UX, Philip M, Richard H, Gullapalli R, Desai JP. Design, Development, and Evaluation of a Master-Slave Surgical System for Breast Biopsy under Continuous MRI. Int J Rob Res 2014; 33:616-630. [PMID: 25313266 PMCID: PMC4193388 DOI: 10.1177/0278364913500365] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Magnetic Resonance Imaging (MRI) provides superior soft-tissue contrast in cancer diagnosis compared to other imaging modalities. However, the strong magnetic field inside the MRI bore along with limited scanner bore size poses significant challenges. Since current approaches in breast biopsy using MR images is primarily a blind targeting approach, it is necessary to develop a MRI-compatible robot that can avoid multiple needle insertions into the breast tissue. This MRI-compatible robotic system could potentially lead to improvement in the targeting accuracy and reduce sampling errors. A master-slave surgical system has been developed comprising of a MRI-compatible slave robot which consists of one piezo motor and five pneumatic cylinders connected by long pneumatic transmission lines. The slave robot follows the configuration of the master robot, which provides an intuitive manipulation interface for the physician and operates inside the MRI bore to adjust the needle position and orientation and perform needle insertion task. Based on the MRI experiments using the slave robot, there was no significant distortion in the images and hence the slave robot can be safely operated inside the MRI with minimal loss in signal-to-noise ratio (SNR). Ex vivo and in vivo experiments have been conducted to evaluate the performance of the master-slave surgical system.
Collapse
Affiliation(s)
- Bo Yang
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Maryland Robotics Center, Institute for System Research, University of Maryland, College Park, MD, USA
| | - Steven Roys
- University of Maryland School of Medicine, Baltimore, MD, USA
| | - U-Xuan Tan
- Singapore University of Technology and Design, Singapore
| | - Mathew Philip
- University of Maryland School of Medicine, Baltimore, MD, USA
| | - Howard Richard
- University of Maryland School of Medicine, Baltimore, MD, USA
| | - Rao Gullapalli
- University of Maryland School of Medicine, Baltimore, MD, USA
| | - Jaydev P Desai
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Maryland Robotics Center, Institute for System Research, University of Maryland, College Park, MD, USA
| |
Collapse
|
15
|
Muller A, Petrusca L, Auboiroux V, Valette PJ, Salomir R, Cotton F. Management of Respiratory Motion in Extracorporeal High-Intensity Focused Ultrasound Treatment in Upper Abdominal Organs: Current Status and Perspectives. Cardiovasc Intervent Radiol 2013; 36:1464-1476. [DOI: 10.1007/s00270-013-0713-0] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/11/2012] [Accepted: 05/08/2013] [Indexed: 12/25/2022]
|
16
|
Niu D, Wang X, Li Y, Zheng Y, Li F, Chen H, Gu J, Zhao W, Shi J. Facile synthesis of magnetite/perfluorocarbon co-loaded organic/inorganic hybrid vesicles for dual-modality ultrasound/magnetic resonance imaging and imaging-guided high-intensity focused ultrasound ablation. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2013; 25:2686-92. [PMID: 23447424 DOI: 10.1002/adma.201204316] [Citation(s) in RCA: 82] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2012] [Revised: 12/21/2012] [Indexed: 05/23/2023]
Abstract
Multifunctional organic/inorganic hybrid nanovesicles, fabricated by a facile self-assembly/sol-gel approach, display a unique morphology (figure) and satisfactory stability under physiological conditions. By co-encapsulation of superparamagnetic magnetite nanoparticles and a liquid perfluorocarbon, the nanovesicles can be used not only as a dual-modality ultrasound/magnetic resonance contrast agent for accurate cancer diagnosis and monitoring, but also as a therapeutic enhancement agent for effective high-intensity focused ultrasound (HIFU) ablation.
Collapse
Affiliation(s)
- Dechao Niu
- Laboratory of Low-Dimensional Materials Chemistry, School of Materials Science and Engineering, East China University of Science and Technology, Shanghai 200237, PR China
| | | | | | | | | | | | | | | | | |
Collapse
|
17
|
Hybrid Ultrasound/Magnetic Resonance Simultaneous Acquisition and Image Fusion for Motion Monitoring in the Upper Abdomen. Invest Radiol 2013; 48:333-40. [DOI: 10.1097/rli.0b013e31828236c3] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
18
|
Bhattacharyya D, Bandyopadhyay SK, Kim TH. Diagnosis of breast cancer by tissue analysis. Chin J Cancer Res 2013; 25:39-45. [PMID: 23372340 DOI: 10.3978/j.issn.1000-9604.2012.12.02] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2012] [Accepted: 12/14/2012] [Indexed: 11/14/2022] Open
Abstract
In this paper, we propose a technique to locate abnormal growth of cells in breast tissue and suggest further pathological test, when require. We compare normal breast tissue with malignant invasive breast tissue by a series of image processing steps. Normal ductal epithelial cells and ductal/lobular invasive carcinogenic cells also consider for comparison here in this paper. In fact, features of cancerous breast tissue (invasive) are extracted and analyses with normal breast tissue. We also suggest the breast cancer recognition technique through image processing and prevention by controlling p53 gene mutation to some extent.
Collapse
Affiliation(s)
- Debnath Bhattacharyya
- Computer Science and Engineering Department, NFET, NSHM Knowledge Campus - Durgapur, Durgapur - 713212, India
| | | | | |
Collapse
|
19
|
Schwartz BM, McDannold NJ. Ultrasound echoes as biometric navigators. Magn Reson Med 2012; 69:1023-33. [PMID: 22648783 DOI: 10.1002/mrm.24336] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2011] [Revised: 04/23/2012] [Accepted: 04/24/2012] [Indexed: 11/06/2022]
Abstract
We demonstrate a new method of using ultrasound data to achieve prospective motion compensation in MRI, especially for respiratory motion during interventional MRI procedures in moving organs such as the liver. The method relies on fingerprint-like biometrically distinct ultrasound echo patterns produced by different locations in tissue, which are collated with geometrical information from MRI during a training stage to form a mapping table that relates ultrasound measurements to positions. During prospective correction, the system makes frequent ultrasound measurements and uses the map to determine the corresponding position. Results in motorized linear motion phantoms and freely breathing animals indicate that the system performs well. Apparent motion is reduced by up to 97.8%, and motion artifacts are reduced or eliminated in two-dimensional spoiled gradient-echo images. The motion compensation is sufficient to permit MRI thermometry of focused ultrasound heating during respiratory-like motion, with results similar to those obtained in the absence of motion. This new technique may have applications for MRI thermometry and other dynamic imaging in the abdomen during free breathing.
Collapse
|
20
|
Auboiroux V, Petrusca L, Viallon M, Goget T, Becker CD, Salomir R. Ultrasonography-based 2D motion-compensated HIFU sonication integrated with reference-free MR temperature monitoring: a feasibility studyex vivo. Phys Med Biol 2012; 57:N159-71. [DOI: 10.1088/0031-9155/57/10/n159] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
|
21
|
Pagel MD. The hope and hype of multimodality imaging contrast agents. Nanomedicine (Lond) 2011; 6:945-8. [DOI: 10.2217/nnm.11.63] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
Affiliation(s)
- Mark D Pagel
- Department of Biomedical Engineering, and, Department of Chemistry & Biochemistry, Arizona Cancer Center, University of Arizona, Tucson, AZ, USA
| |
Collapse
|
22
|
Gandolla M, Ferrante S, Casellato C, Ferrigno G, Molteni F, Martegani A, Frattini T, Pedrocchi A. fMRI brain mapping during motion capture and FES induced motor tasks: signal to noise ratio assessment. Med Eng Phys 2011; 33:1027-32. [PMID: 21550290 DOI: 10.1016/j.medengphy.2011.04.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2010] [Revised: 03/30/2011] [Accepted: 04/06/2011] [Indexed: 11/18/2022]
Abstract
Functional Electrical Stimulation (FES) is a well known clinical rehabilitation procedure, however the neural mechanisms that underlie this treatment at Central Nervous System (CNS) level are still not completely understood. Functional magnetic resonance imaging (fMRI) is a suitable tool to investigate effects of rehabilitative treatments on brain plasticity. Moreover, monitoring the effective executed movement is needed to correctly interpret activation maps, most of all in neurological patients where required motor tasks could be only partially accomplished. The proposed experimental set-up includes a 1.5 T fMRI scanner, a motion capture system to acquire kinematic data, and an electro-stimulation device. The introduction of metallic devices and of stimulation current in the MRI room could affect fMRI acquisitions so as to prevent a reliable activation maps analysis. What we are interested in is that the Blood Oxygenation Level Dependent (BOLD) signal, marker of neural activity, could be detected within a given experimental condition and set-up. In this paper we assess temporal Signal to Noise Ratio (SNR) as image quality index. BOLD signal change is about 1-2% as revealed by a 1.5 T scanner. This work demonstrates that, with this innovative set-up, in the main cortical sensorimotor regions 1% BOLD signal change can be detected at least in the 93% of the sub-volumes, and almost 100% of the sub-volumes are suitable for 2% signal change detection. The integrated experimental set-up will therefore allows to detect FES induced movements fMRI maps simultaneously with kinematic acquisitions so as to investigate FES-based rehabilitation treatments contribution at CNS level.
Collapse
Affiliation(s)
- Marta Gandolla
- Politecnico di Milano, NearLab, Bioengineering Department, Via G. Colombo 40, Milano, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
23
|
Seimenis I, Tsekos NV, Keroglou C, Eracleous E, Pitris C, Christoforou EG. An Approach for Preoperative Planning and Performance of MR-guided Interventions Demonstrated With a Manual Manipulator in a 1.5T MRI Scanner. Cardiovasc Intervent Radiol 2011; 35:359-67. [DOI: 10.1007/s00270-011-0147-5] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/16/2010] [Accepted: 02/25/2011] [Indexed: 10/18/2022]
|
24
|
Chandrana C, Bevan P, Hudson J, Pang I, Burns P, Plewes D, Chopra R. Development of a platform for co-registered ultrasound and MR contrast imagingin vivo. Phys Med Biol 2011; 56:861-77. [DOI: 10.1088/0031-9155/56/3/020] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
25
|
Casellato C, Ferrante S, Gandolla M, Volonterio N, Ferrigno G, Baselli G, Frattini T, Martegani A, Molteni F, Pedrocchi A. Simultaneous measurements of kinematics and fMRI: compatibility assessment and case report on recovery evaluation of one stroke patient. J Neuroeng Rehabil 2010; 7:49. [PMID: 20863391 PMCID: PMC2955635 DOI: 10.1186/1743-0003-7-49] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/25/2010] [Accepted: 09/23/2010] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND Correlating the features of the actual executed movement with the associated cortical activations can enhance the reliability of the functional Magnetic Resonance Imaging (fMRI) data interpretation. This is crucial for longitudinal evaluation of motor recovery in neurological patients and for investigating detailed mutual interactions between activation maps and movement parameters.Therefore, we have explored a new set-up combining fMRI with an optoelectronic motion capture system, which provides a multi-parameter quantification of the performed motor task. METHODS The cameras of the motion system were mounted inside the MR room and passive markers were placed on the subject skin, without any risk or encumbrance. The versatile set-up allows 3-dimensional multi-segment acquisitions including recording of possible mirror movements, and it guarantees a high inter-sessions repeatability.We demonstrated the integrated set-up reliability through compatibility tests. Then, an fMRI block-design protocol combined with kinematic recordings was tested on a healthy volunteer performing finger tapping and ankle dorsal- plantar-flexion. A preliminary assessment of clinical applicability and perspectives was carried out by pre- and post rehabilitation acquisitions on a hemiparetic patient performing ankle dorsal- plantar-flexion. For all sessions, the proposed method integrating kinematic data into the model design was compared with the standard analysis. RESULTS Phantom acquisitions demonstrated the not-compromised image quality. Healthy subject sessions showed the protocols feasibility and the model reliability with the kinematic regressor. The patient results showed that brain activation maps were more consistent when the images analysis included in the regression model, besides the stimuli, the kinematic regressor quantifying the actual executed movement (movement timing and amplitude), proving a significant model improvement. Moreover, concerning motor recovery evaluation, after one rehabilitation month, a greater cortical area was activated during exercise, in contrast to the usual focalization associated with functional recovery. Indeed, the availability of kinematics data allows to correlate this wider area with a higher frequency and a larger amplitude of movement. CONCLUSIONS The kinematic acquisitions resulted to be reliable and versatile to enrich the fMRI images information and therefore the evaluation of motor recovery in neurological patients where large differences between required and performed motion can be expected.
Collapse
Affiliation(s)
- Claudia Casellato
- Politecnico di Milano, Bioengineering Dept, NearLab, piazza L, Da Vinci 32, 20133, Milano, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
26
|
Gray MA, Minati L, Harrison NA, Gianaros PJ, Napadow V, Critchley HD. Physiological recordings: basic concepts and implementation during functional magnetic resonance imaging. Neuroimage 2009; 47:1105-15. [PMID: 19460445 PMCID: PMC2741582 DOI: 10.1016/j.neuroimage.2009.05.033] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2009] [Revised: 05/01/2009] [Accepted: 05/09/2009] [Indexed: 12/30/2022] Open
Abstract
Combining human functional neuroimaging with other forms of psychophysiological measurement, including autonomic monitoring, provides an empirical basis for understanding brain-body interactions. This approach can be applied to characterize unwanted physiological noise, examine the neural control and representation of bodily processes relevant to health and morbidity, and index covert expression of affective and cognitive processes to enhance the interpretation of task-evoked regional brain activity. In recent years, human neuroimaging has been dominated by functional magnetic resonance imaging (fMRI) studies. The spatiotemporal information of fMRI regarding central neural activity is valuably complemented by parallel physiological monitoring, yet such studies still remain in the minority. This review article highlights fMRI studies that employed cardiac, vascular, respiratory, electrodermal, gastrointestinal and pupillary psychophysiological indices to address specific questions regarding interaction between brain and bodily state in the context of experience, cognition, emotion and behaviour. Physiological monitoring within the fMRI environment presents specific technical issues, most importantly related to safety. Mechanical and electrical hazards may present dangers to scanned subjects, operator and/or equipment. Furthermore, physiological monitoring may interfere with the quality of neuroimaging data, or itself be compromised by artefacts induced by the operation of the scanner. We review the sources of these potential problems and the current approaches and advice to enable the combination of fMRI and physiological monitoring in a safe and effective manner.
Collapse
Affiliation(s)
- Marcus A Gray
- Clinical Imaging Sciences Centre and Department of Psychiatry, Brighton and Sussex Medical School, University of Sussex, Falmer Campus, UK.
| | | | | | | | | | | |
Collapse
|