1
|
Deep learning-based rapid image reconstruction and motion correction for high-resolution cartesian first-pass myocardial perfusion imaging at 3T. Magn Reson Med 2024. [PMID: 38576068 DOI: 10.1002/mrm.30106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 03/19/2024] [Accepted: 03/19/2024] [Indexed: 04/06/2024]
Abstract
PURPOSE To develop and evaluate a deep learning (DL) -based rapid image reconstruction and motion correction technique for high-resolution Cartesian first-pass myocardial perfusion imaging at 3T with whole-heart coverage for both single-slice (SS) and simultaneous multi-slice (SMS) acquisitions. METHODS 3D physics-driven unrolled network architectures were utilized for the reconstruction of high-resolution Cartesian perfusion imaging. The SS and SMS multiband (MB) = 2 networks were trained from 135 slices from 20 subjects. Structural similarity index (SSIM), peak SNR (PSNR), and normalized RMS error (NRMSE) were assessed, and prospective images were blindly graded by two experienced cardiologists (5, excellent; 1, poor). For respiratory motion correction, a 2D U-Net based motion corrected network was proposed, and the temporal fidelity and second-order derivative were calculated to assess the performance of the motion correction. RESULTS Excellent performance was demonstrated in the proposed technique with high SSIM and PSNR, and low NRMSE. Image quality scores were (4.3 [4.3, 4.4], 4.5 [4.4, 4.6], 4.3 [4.3, 4.4], and 4.5 [4.3, 4.5]) for SS DL and SS L1-SENSE, MB = 2 DL and MB = 2 SMS-L1-SENSE, respectively, showing no statistically significant difference (p > 0.05 for SS and SMS) between (SMS)-L1-SENSE and the proposed DL technique. The network inference time was around 4 s per dynamic perfusion series with 40 frames while the time of (SMS)-L1-SENSE with GPU acceleration was approximately 30 min. CONCLUSION The proposed DL-based image reconstruction and motion correction technique enabled rapid and high-quality reconstruction for SS and SMS MB = 2 high-resolution Cartesian first-pass perfusion imaging at 3T.
Collapse
|
2
|
Current Research Status of Respiratory Motion for Thorax and Abdominal Treatment: A Systematic Review. Biomimetics (Basel) 2024; 9:170. [PMID: 38534855 DOI: 10.3390/biomimetics9030170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2024] [Revised: 02/29/2024] [Accepted: 03/09/2024] [Indexed: 03/28/2024] Open
Abstract
Malignant tumors have become one of the serious public health problems in human safety and health, among which the chest and abdomen diseases account for the largest proportion. Early diagnosis and treatment can effectively improve the survival rate of patients. However, respiratory motion in the chest and abdomen can lead to uncertainty in the shape, volume, and location of the tumor, making treatment of the chest and abdomen difficult. Therefore, compensation for respiratory motion is very important in clinical treatment. The purpose of this review was to discuss the research and development of respiratory movement monitoring and prediction in thoracic and abdominal surgery, as well as introduce the current research status. The integration of modern respiratory motion compensation technology with advanced sensor detection technology, medical-image-guided therapy, and artificial intelligence technology is discussed and analyzed. The future research direction of intraoperative thoracic and abdominal respiratory motion compensation should be non-invasive, non-contact, use a low dose, and involve intelligent development. The complexity of the surgical environment, the constraints on the accuracy of existing image guidance devices, and the latency of data transmission are all present technical challenges.
Collapse
|
3
|
Automatic calculation of myocardial perfusion reserve using deep learning with uncertainty quantification. Quant Imaging Med Surg 2023; 13:7936-7949. [PMID: 38106294 PMCID: PMC10722070 DOI: 10.21037/qims-23-840] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 08/22/2023] [Indexed: 12/19/2023]
Abstract
Background Myocardial perfusion reserve index (MPRI) in magnetic resonance imaging (MRI) is an important indicator of ischemia, and its measurement typically involves manual procedures. The purposes of this study were to develop a fully automatic method for estimating the MPRI and to evaluate its performance. Methods The method consisted of segmenting the myocardium in dynamic contrast-enhanced (DCE) myocardial perfusion MRI data using Monte Carlo dropout U-Net, dividing the myocardium into segments based on landmark localization with machine learning, and estimating the MPRI after the calculation of the left ventricular and myocardial contrast upslopes. The proposed method was compared with a reference method, which involved manual adjustments of the myocardial contours and upslope ranges. Results In test subjects, MPRIs measured by the proposed technique correlated with those by the manual reference in segmental assessment [intraclass correlation coefficient (ICC) =0.75, 95% CI: 0.70-0.79, P<0.001]. The automatic and reference MPRI values showed a mean difference of -0.02 and 95% limits of agreement of (-0.86, 0.82). Conclusions The proposed automatic method is based on deep learning segmentation and machine learning landmark detection for MPRI measurements in DCE perfusion MRI. It holds the potential to efficiently and quantitatively assess myocardial ischemia without any user's interaction.
Collapse
|
4
|
Comparison of CT-derived Plaque Characteristic Index With CMR Perfusion for Ischemia Diagnosis in Stable CAD. Circ Cardiovasc Imaging 2023; 16:e015773. [PMID: 37725669 DOI: 10.1161/circimaging.123.015773] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 08/21/2023] [Indexed: 09/21/2023]
Abstract
BACKGROUND Coronary computed tomography angiography (CCTA) and cardiac magnetic resonance (CMR) have been used to diagnose lesion-specific ischemia in patients with coronary artery disease. The aim of this study was to investigate the diagnostic performance of CCTA-derived plaque characteristic index compared with myocardial blood flow (MBF) and myocardial perfusion reserve (MPR) derived from CMR perfusion in the assessment of lesion-specific ischemia. METHODS Between October 2020 and March 2022, consecutive patients with suspected or known coronary artery disease, who were clinically referred for invasive coronary angiography were prospectively enrolled. All participants sequentially underwent CCTA and CMR and invasive fractional flow reserve within 2 weeks. The diagnostic performance of CCTA-derived plaque characteristics, CMR perfusion-derived stress MBF, and MPR were compared. Lesions with fractional flow reserve ≤0.80 were considered to be hemodynamically significant stenosis. RESULTS Nighty-two patients with 141 vessels were included in this study. Plaque length, minimum luminal area, plaque area, percent area stenosis, total atheroma volume, vessel volume, lipid-rich volume, spotty calcium, napkin-ring signs, stress MBF, and MPR in flow-limiting stenosis group were significantly different from nonflow-limiting group. The overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of lesion-specific ischemia diagnosis were 61.0%, 55.3%, 63.1%, 35.6%, and 79.3% for stress MBF, and 89.4%, 89.5%, 89.3%, 75.6%, 95.8% for MPR; meanwhile, 82.3%, 79.0%, 84.5%, 65.2%, and 91.6% for CCTA-derived plaque characteristic index. CONCLUSIONS In our prospective study, CCTA-derived plaque characteristics and MPR derived from CMR performed well in diagnosing lesion-specific myocardial ischemia and were significantly better than stress MBF in stable coronary artery disease.
Collapse
|
5
|
Deep Learning-Based Image Registration in Dynamic Myocardial Perfusion CT Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2023; 42:684-696. [PMID: 36227828 DOI: 10.1109/tmi.2022.3214380] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Registration of dynamic CT image sequences is a crucial preprocessing step for clinical evaluation of multiple physiological determinants in the heart such as global and regional myocardial perfusion. In this work, we present a deformable deep learning-based image registration method for quantitative myocardial perfusion CT examinations, which in contrast to previous approaches, takes into account some unique challenges such as low image quality with less accurate anatomical landmarks, dynamic changes of contrast agent concentration in the heart chambers and tissue, and misalignment caused by cardiac stress, respiration, and patient motion. The introduced method uses a recursive cascade network with a ventricle segmentation module, and a novel loss function that accounts for local contrast changes over time. It was trained and validated on a dataset of n = 118 patients with known or suspected coronary artery disease and/or aortic valve insufficiency. Our results demonstrate that the proposed method is capable of registering dynamic cardiac perfusion sequences by reducing local tissue displacements of the left ventricle (LV), whereas contrast changes do not affect the registration and image quality, in particular the absolute CT (HU) values of the entire CT sequence. In addition, the deep learning-based approach presented reveals a short processing time of a few seconds compared to conventional image registration methods, demonstrating its application potential for quantitative CT myocardial perfusion measurements in daily clinical routine.
Collapse
|
6
|
Registration on DCE-MRI images via multi-domain image-to-image translation. Comput Med Imaging Graph 2023; 104:102169. [PMID: 36586196 DOI: 10.1016/j.compmedimag.2022.102169] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2022] [Revised: 12/24/2022] [Accepted: 12/24/2022] [Indexed: 12/29/2022]
Abstract
Registration of dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is challenging as rapid intensity changes caused by a contrast agent lead to large registration errors. To address this problem, we propose a novel multi-domain image-to-image translation (MDIT) network based on image disentangling for separating motion from contrast changes before registration. In particular, the DCE images are disentangled into a domain-invariant content space (motion) and a domain-specific attribute space (contrast changes). The disentangled representations are then used to generate images, where the contrast changes have been removed from the motion. After that the resulting deformations can be directly derived from the generated images using an FFD registration. The method is tested on 10 lung DCE-MRI cases. The proposed method reaches an average root mean squared error of 0.3 ± 0.41 and the separation time is about 2.4 s for each case. Results show that the proposed method improves the registration efficiency without losing the registration accuracy compared with several state-of-the-art registration methods.
Collapse
|
7
|
AI-AIF: artificial intelligence-based arterial input function for quantitative stress perfusion cardiac magnetic resonance. EUROPEAN HEART JOURNAL. DIGITAL HEALTH 2023; 4:12-21. [PMID: 36743875 PMCID: PMC9890084 DOI: 10.1093/ehjdh/ztac074] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/16/2022] [Revised: 10/23/2022] [Indexed: 12/12/2022]
Abstract
Aims One of the major challenges in the quantification of myocardial blood flow (MBF) from stress perfusion cardiac magnetic resonance (CMR) is the estimation of the arterial input function (AIF). This is due to the non-linear relationship between the concentration of gadolinium and the MR signal, which leads to signal saturation. In this work, we show that a deep learning model can be trained to predict the unsaturated AIF from standard images, using the reference dual-sequence acquisition AIFs (DS-AIFs) for training. Methods and results A 1D U-Net was trained, to take the saturated AIF from the standard images as input and predict the unsaturated AIF, using the data from 201 patients from centre 1 and a test set comprised of both an independent cohort of consecutive patients from centre 1 and an external cohort of patients from centre 2 (n = 44). Fully-automated MBF was compared between the DS-AIF and AI-AIF methods using the Mann-Whitney U test and Bland-Altman analysis. There was no statistical difference between the MBF quantified with the DS-AIF [2.77 mL/min/g (1.08)] and predicted with the AI-AIF (2.79 mL/min/g (1.08), P = 0.33. Bland-Altman analysis shows minimal bias between the DS-AIF and AI-AIF methods for quantitative MBF (bias of -0.11 mL/min/g). Additionally, the MBF diagnosis classification of the AI-AIF matched the DS-AIF in 669/704 (95%) of myocardial segments. Conclusion Quantification of stress perfusion CMR is feasible with a single-sequence acquisition and a single contrast injection using an AI-based correction of the AIF.
Collapse
|
8
|
Free-breathing motion-informed locally low-rank quantitative 3D myocardial perfusion imaging. Magn Reson Med 2022; 88:1575-1591. [PMID: 35713206 PMCID: PMC9544898 DOI: 10.1002/mrm.29295] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2021] [Revised: 03/30/2022] [Accepted: 04/19/2022] [Indexed: 12/30/2022]
Abstract
Purpose To propose respiratory motion‐informed locally low‐rank reconstruction (MI‐LLR) for robust free‐breathing single‐bolus quantitative 3D myocardial perfusion CMR imaging. Simulation and in‐vivo results are compared to locally low‐rank (LLR) and compressed sensing reconstructions (CS) for reference. Methods Data were acquired using a 3D Cartesian pseudo‐spiral in‐out k‐t undersampling scheme (R = 10) and reconstructed using MI‐LLR, which encompasses two stages. In the first stage, approximate displacement fields are derived from an initial LLR reconstruction to feed a motion‐compensated reference system to a second reconstruction stage, which reduces the rank of the inverse problem. For comparison, data were also reconstructed with LLR and frame‐by‐frame CS using wavelets as sparsifying transform (ℓ1‐wavelet). Reconstruction accuracy relative to ground truth was assessed using synthetic data for realistic ranges of breathing motion, heart rates, and SNRs. In‐vivo experiments were conducted in healthy subjects at rest and during adenosine stress. Myocardial blood flow (MBF) maps were derived using a Fermi model. Results Improved uniformity of MBF maps with reduced local variations was achieved with MI‐LLR. For rest and stress, intra‐volunteer variation of absolute and relative MBF was lower in MI‐LLR (±0.17 mL/g/min [26%] and ±1.07 mL/g/min [33%]) versus LLR (±0.19 mL/g/min [28%] and ±1.22 mL/g/min [36%]) and versus ℓ1‐wavelet (±1.17 mL/g/min [113%] and ±6.87 mL/g/min [115%]). At rest, intra‐subject MBF variation was reduced significantly with MI‐LLR. Conclusion The combination of pseudo‐spiral Cartesian undersampling and dual‐stage MI‐LLR reconstruction improves free‐breathing quantitative 3D myocardial perfusion CMR imaging under rest and stress condition. Click here for author‐reader discussions
Collapse
|
9
|
Physics-informed neural networks for myocardial perfusion MRI quantification. Med Image Anal 2022; 78:102399. [PMID: 35299005 PMCID: PMC9051528 DOI: 10.1016/j.media.2022.102399] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2020] [Revised: 01/07/2022] [Accepted: 02/18/2022] [Indexed: 11/19/2022]
Abstract
Tracer-kinetic models allow for the quantification of kinetic parameters such as blood flow from dynamic contrast-enhanced magnetic resonance (MR) images. Fitting the observed data with multi-compartment exchange models is desirable, as they are physiologically plausible and resolve directly for blood flow and microvascular function. However, the reliability of model fitting is limited by the low signal-to-noise ratio, temporal resolution, and acquisition length. This may result in inaccurate parameter estimates. This study introduces physics-informed neural networks (PINNs) as a means to perform myocardial perfusion MR quantification, which provides a versatile scheme for the inference of kinetic parameters. These neural networks can be trained to fit the observed perfusion MR data while respecting the underlying physical conservation laws described by a multi-compartment exchange model. Here, we provide a framework for the implementation of PINNs in myocardial perfusion MR. The approach is validated both in silico and in vivo. In the in silico study, an overall decrease in mean-squared error with the ground-truth parameters was observed compared to a standard non-linear least squares fitting approach. The in vivo study demonstrates that the method produces parameter values comparable to those previously found in literature, as well as providing parameter maps which match the clinical diagnosis of patients.
Collapse
|
10
|
High-Resolution Free-Breathing Quantitative First-Pass Perfusion Cardiac MR Using Dual-Echo Dixon With Spatio-Temporal Acceleration. Front Cardiovasc Med 2022; 9:884221. [PMID: 35571164 PMCID: PMC9099052 DOI: 10.3389/fcvm.2022.884221] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 04/04/2022] [Indexed: 11/21/2022] Open
Abstract
Introduction To develop and test the feasibility of free-breathing (FB), high-resolution quantitative first-pass perfusion cardiac MR (FPP-CMR) using dual-echo Dixon (FOSTERS; Fat-water separation for mOtion-corrected Spatio-TEmporally accelerated myocardial peRfuSion). Materials and Methods FOSTERS was performed in FB using a dual-saturation single-bolus acquisition with dual-echo Dixon and a dynamically variable Cartesian k-t undersampling (8-fold) approach, with low-rank and sparsity constrained reconstruction, to achieve high-resolution FPP-CMR images. FOSTERS also included automatic in-plane motion estimation and T2* correction to obtain quantitative myocardial blood flow (MBF) maps. High-resolution (1.6 x 1.6 mm2) FB FOSTERS was evaluated in eleven patients, during rest, against standard-resolution (2.6 x 2.6 mm2) 2-fold SENSE-accelerated breath-hold (BH) FPP-CMR. In addition, MBF was computed for FOSTERS and spatial wavelet-based compressed sensing (CS) reconstruction. Two cardiologists scored the image quality (IQ) of FOSTERS, CS, and standard BH FPP-CMR images using a 4-point scale (1–4, non-diagnostic – fully diagnostic). Results FOSTERS produced high-quality images without dark-rim and with reduced motion-related artifacts, using an 8x accelerated FB acquisition. FOSTERS and standard BH FPP-CMR exhibited excellent IQ with an average score of 3.5 ± 0.6 and 3.4 ± 0.6 (no statistical difference, p > 0.05), respectively. CS images exhibited severe artifacts and high levels of noise, resulting in an average IQ score of 2.9 ± 0.5. MBF values obtained with FOSTERS presented a lower variance than those obtained with CS. Discussion FOSTERS enabled high-resolution FB FPP-CMR with MBF quantification. Combining motion correction with a low-rank and sparsity-constrained reconstruction results in excellent image quality.
Collapse
|
11
|
Clinical Application of Dynamic Contrast Enhanced Perfusion Imaging by Cardiovascular Magnetic Resonance. Front Cardiovasc Med 2021; 8:768563. [PMID: 34778420 PMCID: PMC8585782 DOI: 10.3389/fcvm.2021.768563] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 09/27/2021] [Indexed: 12/12/2022] Open
Abstract
Functionally significant coronary artery disease impairs myocardial blood flow and can be detected non-invasively by myocardial perfusion imaging. While multiple myocardial perfusion imaging modalities exist, the high spatial and temporal resolution of cardiovascular magnetic resonance (CMR), combined with its freedom from ionising radiation make it an attractive option. Dynamic contrast enhanced CMR perfusion imaging has become a well-validated non-invasive tool for the assessment and risk stratification of patients with coronary artery disease and is recommended by international guidelines. This article presents an overview of CMR perfusion imaging and its clinical application, with a focus on chronic coronary syndromes, highlighting its strengths and challenges, and discusses recent advances, including the emerging role of quantitative perfusion analysis.
Collapse
|
12
|
Automated Quantitative Stress Perfusion Cardiac Magnetic Resonance in Pediatric Patients. Front Pediatr 2021; 9:699497. [PMID: 34540764 PMCID: PMC8446614 DOI: 10.3389/fped.2021.699497] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Accepted: 08/05/2021] [Indexed: 11/13/2022] Open
Abstract
Background: Myocardial ischemia occurs in pediatrics, as a result of both congenital and acquired heart diseases, and can lead to further adverse cardiac events if untreated. The aim of this work is to assess the feasibility of fully automated, high resolution, quantitative stress myocardial perfusion cardiac magnetic resonance (CMR) in a cohort of pediatric patients and to evaluate its agreement with the coronary anatomical status of the patients. Methods: Fourteen pediatric patients, with 16 scans, who underwent dual-bolus stress perfusion CMR were retrospectively analyzed. All patients also had anatomical coronary assessment with either CMR, CT, or X-ray angiography. The perfusion CMR images were automatically processed and quantified using an analysis pipeline previously developed in adults. Results: Automated perfusion quantification was successful in 15/16 cases. The coronary perfusion territories supplied by vessels affected by a medium/large aneurysm or stenosis (according to the AHA guidelines), induced by Kawasaki disease, an anomalous origin, or interarterial course had significantly reduced myocardial blood flow (MBF) (median (interquartile range), 1.26 (1.05, 1.67) ml/min/g) as compared to territories supplied by unaffected coronaries [2.57 (2.02, 2.69) ml/min/g, p < 0.001] and territories supplied by vessels with a small aneurysm [2.52 (2.45, 2.83) ml/min/g, p = 0.002]. Conclusion: Automatic CMR-derived MBF quantification is feasible in pediatric patients, and the technology could be potentially used for objective non-invasive assessment of ischemia in children with congenital and acquired heart diseases.
Collapse
|
13
|
Emerging Techniques in Cardiac Magnetic Resonance Imaging. J Magn Reson Imaging 2021; 55:1043-1059. [PMID: 34331487 DOI: 10.1002/jmri.27848] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2021] [Revised: 07/08/2021] [Accepted: 07/09/2021] [Indexed: 11/10/2022] Open
Abstract
Cardiovascular disease is the leading cause of death and a significant contributor of health care costs. Noninvasive imaging plays an essential role in the management of patients with cardiovascular disease. Cardiac magnetic resonance (MR) can noninvasively assess heart and vascular abnormalities, including biventricular structure/function, blood hemodynamics, myocardial tissue composition, microstructure, perfusion, metabolism, coronary microvascular function, and aortic distensibility/stiffness. Its ability to characterize myocardial tissue composition is unique among alternative imaging modalities in cardiovascular disease. Significant growth in cardiac MR utilization, particularly in Europe in the last decade, has laid the necessary clinical groundwork to position cardiac MR as an important imaging modality in the workup of patients with cardiovascular disease. Although lack of availability, limited training, physician hesitation, and reimbursement issues have hampered widespread clinical adoption of cardiac MR in the United States, growing clinical evidence will ultimately overcome these challenges. Advances in cardiac MR techniques, particularly faster image acquisition, quantitative myocardial tissue characterization, and image analysis have been critical to its growth. In this review article, we discuss recent advances in established and emerging cardiac MR techniques that are expected to strengthen its capability in managing patients with cardiovascular disease. LEVEL OF EVIDENCE: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
|
14
|
High spatial resolution spiral first-pass myocardial perfusion imaging with whole-heart coverage at 3 T. Magn Reson Med 2021; 86:648-662. [PMID: 33709415 DOI: 10.1002/mrm.28701] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2020] [Revised: 11/16/2020] [Accepted: 01/04/2021] [Indexed: 11/10/2022]
Abstract
PURPOSE To develop and evaluate a high spatial resolution (1.25 × 1.25 mm2 ) spiral first-pass myocardial perfusion imaging technique with whole-heart coverage at 3T, to better assess transmural differences in perfusion between the endocardium and epicardium, to quantify the myocardial ischemic burden, and to improve the detection of obstructive coronary artery disease. METHODS Whole-heart high-resolution spiral perfusion pulse sequences and corresponding motion-compensated reconstruction techniques for both interleaved single-slice (SS) and simultaneous multi-slice (SMS) acquisition with or without outer-volume suppression (OVS) were developed. The proposed techniques were evaluated in 34 healthy volunteers and 8 patients (55 data sets). SS and SMS images were reconstructed using motion-compensated L1-SPIRiT and SMS-Slice-L1-SPIRiT, respectively. Images were blindly graded by 2 experienced cardiologists on a 5-point scale (5, excellent; 1, poor). RESULTS High-quality perfusion imaging was achieved for both SS and SMS acquisitions with or without OVS. The SS technique without OVS had the highest scores (4.5 [4, 5]), which were greater than scores for SS with OVS (3.5 [3.25, 3.75], P < .05), MB = 2 without OVS (3.75 [3.25, 4], P < .05), and MB = 2 with OVS (3.75 [2.75, 4], P < .05), but significantly higher than those for MB = 3 without OVS (4 [4, 4], P = .95). SMS image quality was improved using SMS-Slice-L1-SPIRiT as compared to SMS-L1-SPIRiT (P < .05 for both reviewers). CONCLUSION We demonstrated the successful implementation of whole-heart spiral perfusion imaging with high resolution at 3T. Good image quality was achieved, and the SS without OVS showed the best image quality. Evaluation in patients with expected ischemic heart disease is warranted.
Collapse
|
15
|
Adaptive Weighting Landmark-Based Group-Wise Registration on Lung DCE-MRI Images. IEEE TRANSACTIONS ON MEDICAL IMAGING 2021; 40:673-687. [PMID: 33136541 DOI: 10.1109/tmi.2020.3035292] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Image registration of lung dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is challenging because the rapid changes in intensity lead to non-realistic deformations of intensity-based registration methods. To address this problem, we propose a novel landmark-based registration framework by incorporating landmark information into a group-wise registration. Robust principal component analysis is used to separate motion from intensity changes caused by a contrast agent. Landmark pairs are detected on the resulting motion components and then incorporated into an intensity-based registration through a constraint term. To reduce the negative effect of inaccurate landmark pairs on registration, an adaptive weighting landmark constraint is proposed. The method for calculating landmark weights is based on an assumption that the displacement of a good matched landmark is consistent with those of its neighbors. The proposed method was tested on 20 clinical lung DCE-MRI image series. Both visual inspection and quantitative assessment are used for the evaluation. Experimental results show that the proposed method effectively reduces the non-realistic deformations in registration and improves the registration performance compared with several state-of-the-art registration methods.
Collapse
|
16
|
High-Resolution Cardiac Magnetic Resonance Imaging Techniques for the Identification of Coronary Microvascular Dysfunction. JACC Cardiovasc Imaging 2020; 14:978-986. [PMID: 33248969 DOI: 10.1016/j.jcmg.2020.10.015] [Citation(s) in RCA: 52] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/07/2020] [Revised: 09/01/2020] [Accepted: 10/14/2020] [Indexed: 12/13/2022]
Abstract
OBJECTIVES This study assessed the ability to identify coronary microvascular dysfunction (CMD) in patients with angina and nonobstructive coronary artery disease (NOCAD) using high-resolution cardiac magnetic resonance (CMR) and hypothesized that quantitative perfusion techniques would have greater accuracy than visual analysis. BACKGROUND Half of all patients with angina are found to have NOCAD, while the presence of CMD portends greater morbidity and mortality, it now represents a modifiable therapeutic target. Diagnosis currently requires invasive assessment of coronary blood flow during angiography. With greater reliance on computed tomography coronary angiography as a first-line tool to investigate angina, noninvasive tests for diagnosing CMD warrant validation. METHODS Consecutive patients with angina and NOCAD were enrolled. Intracoronary pressure and flow measurements were acquired during rest and vasodilator-mediated hyperemia. CMR (3-T) was performed and analyzed by visual and quantitative techniques, including calculation of myocardial blood flow (MBF) during hyperemia (stress MBF), transmural myocardial perfusion reserve (MPR: MBFHYPEREMIA / MBFREST), and subendocardial MPR (MPRENDO). CMD was defined dichotomously as an invasive coronary flow reserve <2.5, with CMR readers blinded to this classification. RESULTS A total of 75 patients were enrolled (57 ± 10 years of age, 81% women). Among the quantitative perfusion indices, MPRENDO and MPR had the highest accuracy (area under the curve [AUC]: 0.90 and 0.88) with high sensitivity and specificity, respectively, both superior to visual assessment (both p < 0.001). Visual assessment identified CMD with 58% accuracy (41% sensitivity and 83% specificity). Quantitative stress MBF performed similarly to visual analysis (AUC: 0.64 vs. 0.60; p = 0.69). CONCLUSIONS High-resolution CMR has good accuracy at detecting CMD but only when analyzed quantitatively. Although omission of rest imaging and stress-only protocols make for quicker scans, this is at the cost of accuracy compared with integrating rest and stress perfusion. Quantitative perfusion CMR has an increasingly important role in the management of patients frequently encountered with angina and NOCAD.
Collapse
|
17
|
Design and evaluation of an abbreviated pixelwise dynamic contrast enhancement analysis protocol for early extracellular volume fraction estimation. Magn Reson Imaging 2020; 76:61-68. [PMID: 33227403 DOI: 10.1016/j.mri.2020.11.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Revised: 11/15/2020] [Accepted: 11/15/2020] [Indexed: 11/30/2022]
Abstract
INTRODUCTION T1-based method is considered as the gold standard for extracellular volume fraction (ECV) mapping. This technique requires at least a 10 min delay after injection to acquire the post injection T1 map. Quantitative analysis of Dynamic Contrast Enhancement (DCE) images could lead to an earlier estimation of an ECV like parameter (2 min). The purpose of this study was to design a quantitative pixel-wise DCE analysis workflow to assess the feasibility of an early estimation of ECV. METHODS Fourteen patients with mitral valve prolapse were included in this study. The MR protocol, performed on a 3 T MR scanner, included MOLLI sequences for T1 maps acquisition and a standard SR-turboFlash sequence for dynamic acquisition. DCE data were acquired for at least 120 s. We implemented a full DCE analysis pipeline with a pre-processing step using an innovative motion correction algorithm (RC-REG algorithm) and a post-processing step using the extended Tofts Model (ECVETM). Estimated ECVETM maps were compared to standard T1-based ECV maps (ECVT1) with both a Pearson correlation analysis and a group-wise analysis. RESULTS Image and map quality assessment showed systematic improvements using the proposed workflow. Strong correlation was found between ECVETM, and ECVT1 values (r-square = 0.87). CONCLUSION A DCE analysis workflow based on RC-REG algorithm and ETM analysis can provide good quality parametric maps. Therefore, it is possible to extract ECV values from a 2 min-long DCE acquisition that are strongly correlated with ECV values from the T1 based method.
Collapse
|
18
|
Feasibility of free-breathing quantitative myocardial perfusion using multi-echo Dixon magnetic resonance imaging. Sci Rep 2020; 10:12684. [PMID: 32728198 PMCID: PMC7392760 DOI: 10.1038/s41598-020-69747-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Accepted: 07/15/2020] [Indexed: 11/08/2022] Open
Abstract
Dynamic contrast-enhanced quantitative first-pass perfusion using magnetic resonance imaging enables non-invasive objective assessment of myocardial ischemia without ionizing radiation. However, quantification of perfusion is challenging due to the non-linearity between the magnetic resonance signal intensity and contrast agent concentration. Furthermore, respiratory motion during data acquisition precludes quantification of perfusion. While motion correction techniques have been proposed, they have been hampered by the challenge of accounting for dramatic contrast changes during the bolus and long execution times. In this work we investigate the use of a novel free-breathing multi-echo Dixon technique for quantitative myocardial perfusion. The Dixon fat images, unaffected by the dynamic contrast-enhancement, are used to efficiently estimate rigid-body respiratory motion and the computed transformations are applied to the corresponding diagnostic water images. This is followed by a second non-linear correction step using the Dixon water images to remove residual motion. The proposed Dixon motion correction technique was compared to the state-of-the-art technique (spatiotemporal based registration). We demonstrate that the proposed method performs comparably to the state-of-the-art but is significantly faster to execute. Furthermore, the proposed technique can be used to correct for the decay of signal due to T2* effects to improve quantification and additionally, yields fat-free diagnostic images.
Collapse
|
19
|
Deep-Learning-Based Preprocessing for Quantitative Myocardial Perfusion MRI. J Magn Reson Imaging 2020; 51:1689-1696. [PMID: 31710769 PMCID: PMC7317373 DOI: 10.1002/jmri.26983] [Citation(s) in RCA: 40] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2019] [Revised: 10/11/2019] [Accepted: 10/16/2019] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Quantitative myocardial perfusion cardiac MRI can provide a fast and robust assessment of myocardial perfusion status for the noninvasive diagnosis of myocardial ischemia while being more objective than visual assessment. However, it currently has limited use in clinical practice due to the challenging postprocessing required, particularly the segmentation. PURPOSE To evaluate the efficacy of an automated deep learning (DL) pipeline for image processing prior to quantitative analysis. STUDY TYPE Retrospective. POPULATION In all, 175 (350 MRI scans; 1050 image series) clinical patients under both rest and stress conditions (135/10/30 training/validation/test). FIELD STRENGTH/SEQUENCE 3.0T/2D multislice saturation recovery T1 -weighted gradient echo sequence. ASSESSMENT Accuracy was assessed, as compared to the manual operator, through the mean square error of the distance between landmarks and the Dice similarity coefficient of the segmentation and bounding box detection. Quantitative perfusion maps obtained using the automated DL-based processing were compared to the results obtained with the manually processed images. STATISTICAL TESTS Bland-Altman plots and intraclass correlation coefficient (ICC) were used to assess the myocardial blood flow (MBF) obtained using the automated DL pipeline, as compared to values obtained by a manual operator. RESULTS The mean (SD) error in the detection of the time of peak signal enhancement in the left ventricle was 1.49 (1.4) timeframes. The mean (SD) Dice similarity coefficients for the bounding box and myocardial segmentation were 0.93 (0.03) and 0.80 (0.06), respectively. The mean (SD) error in the RV insertion point was 2.8 (1.8) mm. The Bland-Altman plots showed a bias of 2.6% of the mean MBF between the automated and manually processed MBF values on a per-myocardial segment basis. The ICC was 0.89, 95% confidence interval = [0.87, 0.90]. DATA CONCLUSION We showed high accuracy, compared to manual processing, for the DL-based processing of myocardial perfusion data leading to quantitative values that are similar to those achieved with manual processing. LEVEL OF EVIDENCE 3 Technical Efficacy Stage: 1 J. Magn. Reson. Imaging 2020;51:1689-1696.
Collapse
|
20
|
Automated detection of left ventricle in arterial input function images for inline perfusion mapping using deep learning: A study of 15,000 patients. Magn Reson Med 2020; 84:2788-2800. [DOI: 10.1002/mrm.28291] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2019] [Revised: 03/30/2020] [Accepted: 03/30/2020] [Indexed: 12/21/2022]
|
21
|
Hierarchical Bayesian myocardial perfusion quantification. Med Image Anal 2020; 60:101611. [PMID: 31760191 PMCID: PMC6880627 DOI: 10.1016/j.media.2019.101611] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 11/07/2019] [Accepted: 11/08/2019] [Indexed: 01/25/2023]
Abstract
Myocardial blood flow can be quantified from dynamic contrast-enhanced magnetic resonance (MR) images through the fitting of tracer-kinetic models to the observed imaging data. The use of multi-compartment exchange models is desirable as they are physiologically motivated and resolve directly for both blood flow and microvascular function. However, the parameter estimates obtained with such models can be unreliable. This is due to the complexity of the models relative to the observed data which is limited by the low signal-to-noise ratio, the temporal resolution, the length of the acquisitions and other complex imaging artefacts. In this work, a Bayesian inference scheme is proposed which allows the reliable estimation of the parameters of the two-compartment exchange model from myocardial perfusion MR data. The Bayesian scheme allows the incorporation of prior knowledge on the physiological ranges of the model parameters and facilitates the use of the additional information that neighbouring voxels are likely to have similar kinetic parameter values. Hierarchical priors are used to avoid making a priori assumptions on the health of the patients. We provide both a theoretical introduction to Bayesian inference for tracer-kinetic modelling and specific implementation details for this application. This approach is validated in both in silico and in vivo settings. In silico, there was a significant reduction in mean-squared error with the ground-truth parameters using Bayesian inference as compared to using the standard non-linear least squares fitting. When applied to patient data the Bayesian inference scheme returns parameter values that are in-line with those previously reported in the literature, as well as giving parameter maps that match the independant clinical diagnosis of those patients.
Collapse
|
22
|
Automatic in-line quantitative myocardial perfusion mapping: Processing algorithm and implementation. Magn Reson Med 2020; 83:712-730. [PMID: 31441550 PMCID: PMC8400845 DOI: 10.1002/mrm.27954] [Citation(s) in RCA: 27] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2019] [Revised: 06/27/2019] [Accepted: 07/27/2019] [Indexed: 02/03/2023]
Abstract
PURPOSE Quantitative myocardial perfusion mapping has advantages over qualitative assessment, including the ability to detect global flow reduction. However, it is not clinically available and remains a research tool. Building upon the previously described imaging sequence, this study presents algorithm and implementation of an automated solution for inline perfusion flow mapping with step by step performance characterization. METHODS Proposed workflow consists of motion correction (MOCO), arterial input function blood detection, intensity to gadolinium concentration conversion, and pixel-wise mapping. A distributed kinetics model, blood-tissue exchange model, is implemented, computing pixel-wise maps of myocardial blood flow (mL/min/g), permeability-surface-area product (mL/min/g), blood volume (mL/g), and interstitial volume (mL/g). RESULTS Thirty healthy subjects (11 men; 26.4 ± 10.4 years) were recruited and underwent adenosine stress perfusion cardiovascular MR. Mean MOCO quality score was 3.6 ± 0.4 for stress and 3.7 ± 0.4 for rest. Myocardial Dice similarity coefficients after MOCO were significantly improved (P < 1e-6), 0.87 ± 0.05 for stress and 0.86 ± 0.06 for rest. Arterial input function peak gadolinium concentration was 4.4 ± 1.3 mmol/L at stress and 5.2 ± 1.5 mmol/L at rest. Mean myocardial blood flow at stress and rest were 2.82 ± 0.47 mL/min/g and 0.68 ± 0.16 mL/min/g, respectively. The permeability-surface-area product was 1.32 ± 0.26 mL/min/g at stress and 1.09 ± 0.21 mL/min/g at rest (P < 1e-3). Blood volume was 12.0 ± 0.8 mL/100 g at stress and 9.7 ± 1.0 mL/100 g at rest (P < 1e-9), indicating good adenosine vasodilation response. Interstitial volume was 20.8 ± 2.5 mL/100 g at stress and 20.3 ± 2.9 mL/100 g at rest (P = 0.50). CONCLUSIONS An inline perfusion flow mapping workflow is proposed and demonstrated on normal volunteers. Initial evaluation demonstrates this fully automated solution for the respiratory MOCO, arterial input function left ventricle mask detection, and pixel-wise mapping, from free-breathing myocardial perfusion imaging.
Collapse
|
23
|
Coronary Microvascular Dysfunction Is Associated With Myocardial Ischemia and Abnormal Coronary Perfusion During Exercise. Circulation 2019; 140:1805-1816. [PMID: 31707835 PMCID: PMC6882540 DOI: 10.1161/circulationaha.119.041595] [Citation(s) in RCA: 105] [Impact Index Per Article: 21.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/01/2019] [Accepted: 10/15/2019] [Indexed: 12/14/2022]
Abstract
BACKGROUND Coronary microvascular dysfunction (MVD) is defined by impaired flow augmentation in response to a pharmacological vasodilator in the presence of nonobstructive coronary artery disease. It is unknown whether diminished coronary vasodilator response correlates with abnormal exercise physiology or inducible myocardial ischemia. METHODS Patients with angina and nonobstructive coronary artery disease had simultaneous coronary pressure and flow velocity measured using a dual sensor-tipped guidewire during rest, supine bicycle exercise, and adenosine-mediated hyperemia. Microvascular resistance (MR) was calculated as coronary pressure divided by flow velocity. Wave intensity analysis quantified the proportion of accelerating wave energy (perfusion efficiency). Global myocardial blood flow and subendocardial:subepicardial perfusion ratio were quantified using 3-Tesla cardiac magnetic resonance imaging during hyperemia and rest; inducible ischemia was defined as hyperemic subendocardial:subepicardial perfusion ratio <1.0. Patients were classified as having MVD if coronary flow reserve <2.5 and controls if coronary flow reserve ≥2.5, with researchers blinded to the classification. RESULTS Eighty-five patients were enrolled (78% female, 57±10 years), 45 (53%) were classified as having MVD. Of the MVD group, 82% had inducible ischemia compared with 22% of controls (P<0.001); global myocardial perfusion reserve was 2.01±0.41 and 2.68±0.49 (P<0.001). In controls, coronary perfusion efficiency improved from rest to exercise and was unchanged during hyperemia (59±11% vs 65±14% vs 57±18%; P=0.02 and P=0.14). In contrast, perfusion efficiency decreased during both forms of stress in MVD (61±12 vs 44±10 vs 42±11%; both P<0.001). Among patients with a coronary flow reserve <2.5, 62% had functional MVD, with normal minimal MR (hyperemic MR<2.5 mmHg/cm/s), and 38% had structural MVD with elevated hyperemic MR. Resting MR was lower in those with functional MVD (4.2±1.0 mmHg/cm/s) than in those with structural MVD (6.9±1.7 mmHg/cm/s) or controls (7.3±2.2 mmHg/cm/s; both P<0.001). During exercise, the structural group had a higher systolic blood pressure (188±25 mmHg) than did those with functional MVD (161±27 mmHg; P=0.004) and controls (156±30 mmHg; P<0.001). Functional and structural MVD had similar stress myocardial perfusion and exercise perfusion efficiency values. CONCLUSION In patients with angina and nonobstructive coronary artery disease, diminished coronary flow reserve characterizes a cohort with inducible ischemia and a maladaptive physiological response to exercise. We have identified 2 endotypes of MVD with distinctive systemic vascular responses to exercise; whether endotypes have a different prognosis or require different treatments merits further investigation.
Collapse
|
24
|
Motion correction of chemical exchange saturation transfer MRI series using robust principal component analysis (RPCA) and PCA. Quant Imaging Med Surg 2019; 9:1697-1713. [PMID: 31728313 PMCID: PMC6828584 DOI: 10.21037/qims.2019.09.14] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Accepted: 09/10/2019] [Indexed: 12/28/2022]
Abstract
BACKGROUND Chemical exchange saturation transfer (CEST) MRI requires the acquisition of multiple saturation-weighted images and can last several minutes. Misalignments among these images, which are often due to the inevitable motion of the subject, will corrupt CEST contrast maps and result in large quantification errors. Therefore, the registration of the CEST series is critical. However, registration is challenging since common intensity-based registration algorithms may fail to differentiate CEST signals from motion artifacts. Herein, we studied how different patterns of motion affect CEST quantification and proposed a cascaded two-step registration scheme by utilizing features extracted from the entire Z-spectral image series instead of direct registration to a single image. METHODS The proposed approach is conducted in two stages: during the first coarse registration, the Z-spectral image series is decomposed by robust principal component analysis (RPCA) to separate CEST contrast from motion. The recomposed image series using only the low-rank component, which contains minimized motion, are averaged to generate a reference for the alignment of the image series. To further remove residual misalignments, the coarse registration is followed by a refinement stage, which uses PCA iteratively to generate motionless synthetic reference series with the first few principal components (PCs) that correspond to CEST contrast. In the end, the quality check is performed to exclude the images with unsuccessful registration. RESULTS The proposed registration scheme (RPCA + PCA_R) was assessed by both phantom experiments and in vivo data of tumor-bearing mouse brain, with simulated random rigid motion in different patterns applied to the acquired static Z-spectral image series. For comparison, previous correction schemes using an explicit image [either S0 or Ssat(∆ω)] as registration reference were also performed, named as S0_R and Ssat_R respectively. To illustrate the advantage of combination of RPCA and PCA, registration was also exploited using either only the RPCA-based method (RPCA_R) or only the PCA-based one (PCA_R). Compared with the above four methods, RPCA + PCA_R allowed for more accurate correction of the corrupted Z-spectral images, exhibiting smaller MTRasym(∆ω) error maps and lower residual Z-spectra referring to the static data. Among all the five correction methods, the corrected Z-spectral image series by RPCA + PCA_R and the resulting MTRasym(∆ω) maps achieved the highest correlation coefficients (CC) with respect to the static ones. CONCLUSIONS The registration scheme of RPCA + PCA_R provides robust motion correction between two specific Z-spectral images and among an entire image series, through extraction of the static component from the entire Z-spectra set and inclusion of a PCA-based refinement step. Therefore, this method can help improve CEST acquisition and quantification.
Collapse
|