Cortical Auditory Evoked Potentials Recorded Directly Through the Cochlear Implant in Cochlear Implant Recipients: a Feasibility Study. Ear Hear 2022; 43:1426-1436. [DOI: 10.1097/aud.0000000000001212] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
2
|
Bauernfeind G, Teschner MJ, Wriessnegger S, Büchner A, Lenarz T, Haumann S. Towards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users. J Neural Eng 2022; 19. [PMID: 35189612 DOI: 10.1088/1741-2552/ac572d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 02/21/2022] [Indexed: 11/12/2022]
Abstract
OBJECTIVE One promising approach towards further improving cochlear implants (CIs) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, greater robustness to artefacts, and thus enhanced classification accuracy. APPROACH In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. MAIN RESULTS Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance: The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.
Collapse
Affiliation(s)
- Guenther Bauernfeind
- Independent researcher; Former member of the Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover, 30625, GERMANY
| | - Magnus Johannes Teschner
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str. 1, Hannover, Niedersachsen, 30625, GERMANY
| | - Selina Wriessnegger
- Department of Psychology, Karl Franzens Universitaet Graz, Universitätsplatz 2 / III, A-8010 Graz, Austria, Graz, A-8010, AUSTRIA
| | - Andreas Büchner
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str.1, Hannover, Niedersachsen, 30625, GERMANY
| | - Thomas Lenarz
- Department of Otolaryngology, Hannover Medical School, Carl-Neubergstr. 1, 30625 Hannover, Germany, Hannover, Niedersachsen, 30625, GERMANY
| | - Sabine Haumann
- Department of Otolaryngology, Hannover Medical School, Carl-Neuberg-Str.1, Hannover, Niedersachsen, 30625, GERMANY
| |
Collapse
|
3
|
Aldag N, Büchner A, Lenarz T, Nogueira W. Towards decoding selective attention through cochlear implant electrodes as sensors in subjects with contralateral acoustic hearing. J Neural Eng 2022; 19. [DOI: 10.1088/1741-2552/ac4de6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Accepted: 01/21/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objectives: Focusing attention on one speaker in a situation with multiple background speakers or noise is referred to as auditory selective attention. Decoding selective attention is an interesting line of research with respect to future brain-guided hearing aids or cochlear implants (CIs) that are designed to adaptively adjust sound processing through cortical feedback loops. This study investigates the feasibility of using the electrodes and backward telemetry of a CI to record electroencephalography (EEG). Approach: The study population included 6 normal-hearing (NH) listeners and 5 CI users with contralateral acoustic hearing. Cortical auditory evoked potentials (CAEP) and selective attention were recorded using a state-of-the-art high-density scalp EEG and, in the case of CI users, also using two CI electrodes as sensors in combination with the backward telemetry system of these devices (iEEG). Main results: In the selective attention paradigm with multi-channel scalp EEG the mean decoding accuracy across subjects was 94.8 % and 94.6 % for NH listeners and CI users, respectively. With single-channel scalp EEG the accuracy dropped but was above chance level in 8 to 9 out of 11 subjects, depending on the electrode montage. With the single-channel iEEG, the selective attention decoding accuracy could only be analyzed in 2 out of 5 CI users due to a loss of data in the other 3 subjects. In these 2 CI users, the selective attention decoding accuracy was above chance level. Significance: This study shows that single-channel EEG is suitable for auditory selective attention decoding, even though it reduces the decoding quality compared to a multi-channel approach. CI-based iEEG can be used for the purpose of recording CAEPs and decoding selective attention. However, the study also points out the need for further technical development for the CI backward telemetry regarding long-term recordings and the optimal sensor positions.
Collapse
|
4
|
Beynon AJ, Luijten BM, Mylanus EAM. Intracorporeal Cortical Telemetry as a Step to Automatic Closed-Loop EEG-Based CI Fitting: A Proof of Concept. Audiol Res 2021; 11:691-705. [PMID: 34940020 PMCID: PMC8698912 DOI: 10.3390/audiolres11040062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2021] [Revised: 11/04/2021] [Accepted: 12/09/2021] [Indexed: 11/16/2022] Open
Abstract
Electrically evoked auditory potentials have been used to predict auditory thresholds in patients with a cochlear implant (CI). However, with exception of electrically evoked compound action potentials (eCAP), conventional extracorporeal EEG recording devices are still needed. Until now, built-in (intracorporeal) back-telemetry options are limited to eCAPs. Intracorporeal recording of auditory responses beyond the cochlea is still lacking. This study describes the feasibility of obtaining longer latency cortical responses by concatenating interleaved short recording time windows used for eCAP recordings. Extracochlear reference electrodes were dedicated to record cortical responses, while intracochlear electrodes were used for stimulation, enabling intracorporeal telemetry (i.e., without an EEG device) to assess higher cortical processing in CI recipients. Simultaneous extra- and intra-corporeal recordings showed that it is feasible to obtain intracorporeal slow vertex potentials with a CI similar to those obtained by conventional extracorporeal EEG recordings. Our data demonstrate a proof of concept of closed-loop intracorporeal auditory cortical response telemetry (ICT) with a cochlear implant device. This research breaks new ground for next generation CI devices to assess higher cortical neural processing based on acute or continuous EEG telemetry to enable individualized automatic and/or adaptive CI fitting with only a CI.
Collapse
Affiliation(s)
- Andy J. Beynon
- Vestibular & Auditory Evoked Potential Lab, Department Oto-Rhino-Laryngology, Head & Neck Surgery, 6525 EX Nijmegen, The Netherlands
- Hearing & Implants, Department Oto-Rhino-Laryngology, Head & Neck Surgery, Donders Center Medical Neuroscience, 6525 EX Nijmegen, The Netherlands; (B.M.L.); (E.A.M.M.)
- Correspondence:
| | - Bart M. Luijten
- Hearing & Implants, Department Oto-Rhino-Laryngology, Head & Neck Surgery, Donders Center Medical Neuroscience, 6525 EX Nijmegen, The Netherlands; (B.M.L.); (E.A.M.M.)
| | - Emmanuel A. M. Mylanus
- Hearing & Implants, Department Oto-Rhino-Laryngology, Head & Neck Surgery, Donders Center Medical Neuroscience, 6525 EX Nijmegen, The Netherlands; (B.M.L.); (E.A.M.M.)
| |
Collapse
|
5
|
A Neural Recording and Stimulation Chip with Artifact Suppression for Biomedical Devices. JOURNAL OF HEALTHCARE ENGINEERING 2021; 2021:4153155. [PMID: 34484653 PMCID: PMC8416399 DOI: 10.1155/2021/4153155] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Accepted: 08/18/2021] [Indexed: 11/30/2022]
Abstract
This paper presents chip implementation of the integrated neural recording and stimulation system with stimulation-induced artifact suppression. The implemented chip consists of low-power neural recording circuits, stimulation circuits, and action potential detection circuits. These circuits constitute a closed-loop simultaneous neural recording and stimulation system for biomedical devices, and a proposed artifact suppression technique is used in the system. Moreover, this paper also presents the measurement and experiment results of the implemented 4-to-4 channel neural recording and stimulation chip with 0.18 µm CMOS technology. The function and efficacy of simultaneous neural recording and stimulation is validated in both in vivo and animal experiments.
Collapse
|
6
|
Li J, Liu X, Mao W, Chen T, Yu H. Advances in Neural Recording and Stimulation Integrated Circuits. Front Neurosci 2021; 15:663204. [PMID: 34421507 PMCID: PMC8377741 DOI: 10.3389/fnins.2021.663204] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Accepted: 07/08/2021] [Indexed: 11/13/2022] Open
Abstract
In the past few decades, driven by the increasing demands in the biomedical field aiming to cure neurological diseases and improve the quality of daily lives of the patients, researchers began to take advantage of the semiconductor technology to develop miniaturized and power-efficient chips for implantable applications. The emergence of the integrated circuits for neural prosthesis improves the treatment process of epilepsy, hearing loss, retinal damage, and other neurological diseases, which brings benefits to many patients. However, considering the safety and accuracy in the neural prosthesis process, there are many research directions. In the process of chip design, designers need to carefully analyze various parameters, and investigate different design techniques. This article presents the advances in neural recording and stimulation integrated circuits, including (1) a brief introduction of the basics of neural prosthesis circuits and the repair process in the bionic neural link, (2) a systematic introduction of the basic architecture and the latest technology of neural recording and stimulation integrated circuits, (3) a summary of the key issues of neural recording and stimulation integrated circuits, and (4) a discussion about the considerations of neural recording and stimulation circuit architecture selection and a discussion of future trends. The overview would help the designers to understand the latest performances in many aspects and to meet the design requirements better.
Collapse
Affiliation(s)
- Juzhe Li
- College of Microelectronics, Beijing University of Technology, Beijing, China
| | - Xu Liu
- College of Microelectronics, Beijing University of Technology, Beijing, China
| | - Wei Mao
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, China
| | - Tao Chen
- Advanced Photonics Institute, Beijing University of Technology, Beijing, China
| | - Hao Yu
- School of Microelectronics, Southern University of Science and Technology, Shenzhen, China
| |
Collapse
|
7
|
EEG-based diagnostics of the auditory system using cochlear implant electrodes as sensors. Sci Rep 2021; 11:5383. [PMID: 33686155 PMCID: PMC7940426 DOI: 10.1038/s41598-021-84829-y] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2020] [Accepted: 02/18/2021] [Indexed: 01/31/2023] Open
Abstract
The cochlear implant is one of the most successful medical prostheses, allowing deaf and severely hearing-impaired persons to hear again by electrically stimulating the auditory nerve. A trained audiologist adjusts the stimulation settings for good speech understanding, known as "fitting" the implant. This process is based on subjective feedback from the user, making it time-consuming and challenging, especially in paediatric or communication-impaired populations. Furthermore, fittings only happen during infrequent sessions at a clinic, and therefore cannot take into account variable factors that affect the user's hearing, such as physiological changes and different listening environments. Objective audiometry, in which brain responses evoked by auditory stimulation are collected and analysed, removes the need for active patient participation. However, recording of brain responses still requires expensive equipment that is cumbersome to use. An elegant solution is to record the neural signals using the implant itself. We demonstrate for the first time the recording of continuous electroencephalographic (EEG) signals from the implanted intracochlear electrode array in human subjects, using auditory evoked potentials originating from different brain regions. This was done using a temporary recording set-up with a percutaneous connector used for research purposes. Furthermore, we show that the response morphologies and amplitudes depend crucially on the recording electrode configuration. The integration of an EEG system into cochlear implants paves the way towards chronic neuro-monitoring of hearing-impaired patients in their everyday environment, and neuro-steered hearing prostheses, which can autonomously adjust their output based on neural feedback.
Collapse
|
8
|
|
9
|
Wang L, Wu EX, Chen F. Robust EEG-Based Decoding of Auditory Attention With High-RMS-Level Speech Segments in Noisy Conditions. Front Hum Neurosci 2020; 14:557534. [PMID: 33132874 PMCID: PMC7576187 DOI: 10.3389/fnhum.2020.557534] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2020] [Accepted: 09/09/2020] [Indexed: 11/25/2022] Open
Abstract
The attended speech stream can be detected robustly, even in adverse auditory scenarios with auditory attentional modulation, and can be decoded using electroencephalographic (EEG) data. Speech segmentation based on the relative root-mean-square (RMS) intensity can be used to estimate segmental contributions to perception in noisy conditions. High-RMS-level segments contain crucial information for speech perception. Hence, this study aimed to investigate the effect of high-RMS-level speech segments on auditory attention decoding performance under various signal-to-noise ratio (SNR) conditions. Scalp EEG signals were recorded when subjects listened to the attended speech stream in the mixed speech narrated concurrently by two Mandarin speakers. The temporal response function was used to identify the attended speech from EEG responses of tracking to the temporal envelopes of intact speech and high-RMS-level speech segments alone, respectively. Auditory decoding performance was then analyzed under various SNR conditions by comparing EEG correlations to the attended and ignored speech streams. The accuracy of auditory attention decoding based on the temporal envelope with high-RMS-level speech segments was not inferior to that based on the temporal envelope of intact speech. Cortical activity correlated more strongly with attended than with ignored speech under different SNR conditions. These results suggest that EEG recordings corresponding to high-RMS-level speech segments carry crucial information for the identification and tracking of attended speech in the presence of background noise. This study also showed that with the modulation of auditory attention, attended speech can be decoded more robustly from neural activity than from behavioral measures under a wide range of SNR.
Collapse
Affiliation(s)
- Lei Wang
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China.,Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, Hong Kong
| | - Ed X Wu
- Department of Electrical and Electronic Engineering, The University of Hong Kong, Hong Kong, Hong Kong
| | - Fei Chen
- Department of Electrical and Electronic Engineering, Southern University of Science and Technology, Shenzhen, China
| |
Collapse
|
10
|
Sadeghi Najafabadi M, Chen L, Dutta K, Norris A, Feng B, Schnupp JWH, Rosskothen-Kuhl N, Read HL, Escabí MA. Optimal Multichannel Artifact Prediction and Removal for Neural Stimulation and Brain Machine Interfaces. Front Neurosci 2020; 14:709. [PMID: 32765212 PMCID: PMC7379342 DOI: 10.3389/fnins.2020.00709] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/21/2019] [Accepted: 06/11/2020] [Indexed: 11/13/2022] Open
Abstract
Neural implants that deliver multi-site electrical stimulation to the nervous systems are no longer the last resort but routine treatment options for various neurological disorders. Multi-site electrical stimulation is also widely used to study nervous system function and neural circuit transformations. These technologies increasingly demand dynamic electrical stimulation and closed-loop feedback control for real-time assessment of neural function, which is technically challenging since stimulus-evoked artifacts overwhelm the small neural signals of interest. We report a novel and versatile artifact removal method that can be applied in a variety of settings, from single- to multi-site stimulation and recording and for current waveforms of arbitrary shape and size. The method capitalizes on linear electrical coupling between stimulating currents and recording artifacts, which allows us to estimate a multi-channel linear Wiener filter to predict and subsequently remove artifacts via subtraction. We confirm and verify the linearity assumption and demonstrate feasibility in a variety of recording modalities, including in vitro sciatic nerve stimulation, bilateral cochlear implant stimulation, and multi-channel stimulation and recording between the auditory midbrain and cortex. We demonstrate a vast enhancement in the recording quality with a typical artifact reduction of 25-40 dB. The method is efficient and can be scaled to arbitrary number of stimulus and recording sites, making it ideal for applications in large-scale arrays, closed-loop implants, and high-resolution multi-channel brain-machine interfaces.
Collapse
Affiliation(s)
- Mina Sadeghi Najafabadi
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, United States
| | - Longtu Chen
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States
| | - Kelsey Dutta
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, United States
| | - Ashley Norris
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States
| | - Bin Feng
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States
| | - Jan W. H. Schnupp
- Department of Biomedical Sciences, City University of Hong Kong, Kowloon, Hong Kong
- Shenzhen Research Institute, City University of Hong Kong, Shenzhen, China
| | - Nicole Rosskothen-Kuhl
- Department of Biomedical Sciences, City University of Hong Kong, Kowloon, Hong Kong
- Neurobiological Research Laboratory, Section for Clinical and Experimental Otology, University Medical Center Freiburg, Freiburg im Breisgau, Germany
| | - Heather L. Read
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States
- Department of Psychology, University of Connecticut, Storrs, CT, United States
- The Connecticut Institute for the Brain and Cognitive Sciences, University of Connecticut, Storrs, CT, United States
| | - Monty A. Escabí
- Department of Electrical and Computer Engineering, University of Connecticut, Storrs, CT, United States
- Department of Biomedical Engineering, University of Connecticut, Storrs, CT, United States
- Department of Psychology, University of Connecticut, Storrs, CT, United States
- The Connecticut Institute for the Brain and Cognitive Sciences, University of Connecticut, Storrs, CT, United States
| |
Collapse
|
11
|
Zhou H, Wang N, Zheng N, Yu G, Meng Q. A New Approach for Noise Suppression in Cochlear Implants: A Single-Channel Noise Reduction Algorithm. Front Neurosci 2020; 14:301. [PMID: 32372902 PMCID: PMC7186595 DOI: 10.3389/fnins.2020.00301] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Accepted: 03/16/2020] [Indexed: 12/11/2022] Open
Abstract
The cochlea “translates” the in-air vibrational acoustic “language” into the spikes of neural “language” that are then transmitted to the brain for auditory understanding and/or perception. During this intracochlear “translation” process, high resolution in time–frequency–intensity domains guarantees the high quality of the input neural information for the brain, which is vital for our outstanding hearing abilities. However, cochlear implants (CIs) have coarse artificial coding and interfaces, and CI users experience more challenges in common acoustic environments than their normal-hearing (NH) peers. Noise from sound sources that a listener has no interest in may be neglected by NH listeners, but they may distract a CI user. We discuss the CI noise-suppression techniques and introduce noise management for a new implant system. The monaural signal-to-noise ratio estimation-based noise suppression algorithm “eVoice,” which is incorporated in the processors of Nurotron® EnduroTM, was evaluated in two speech perception experiments. The results show that speech intelligibility in stationary speech-shaped noise can be significantly improved with eVoice. Similar results have been observed in other CI devices with single-channel noise reduction techniques. Specifically, the mean speech reception threshold decrease in the present study was 2.2 dB. The Nurotron society already has more than 10,000 users, and eVoice is a start for noise management in the new system. Future steps on non-stationary-noise suppression, spatial-source separation, bilateral hearing, microphone configuration, and environment specification are warranted. The existing evidence, including our research, suggests that noise-suppression techniques should be applied in CI systems. The artificial hearing of CI listeners requires more advanced signal processing techniques to reduce brain effort and increase intelligibility in noisy settings.
Collapse
Affiliation(s)
- Huali Zhou
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| | | | - Nengheng Zheng
- The Guangdong Key Laboratory of Intelligent Information Processing, College of Electronics and Information Engineering, Shenzhen University, Shenzhen, China
| | - Guangzheng Yu
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| | - Qinglin Meng
- Acoustics Lab, School of Physics and Optoelectronics, South China University of Technology, Guangzhou, China
| |
Collapse
|
12
|
Zeng FG, Tran P, Richardson M, Sun S, Xu Y. Human Sensation of Transcranial Electric Stimulation. Sci Rep 2019; 9:15247. [PMID: 31649289 PMCID: PMC6813324 DOI: 10.1038/s41598-019-51792-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Accepted: 10/08/2019] [Indexed: 01/22/2023] Open
Abstract
Noninvasive transcranial electric stimulation is increasingly being used as an advantageous therapy alternative that may activate deep tissues while avoiding drug side-effects. However, not only is there limited evidence for activation of deep tissues by transcranial electric stimulation, its evoked human sensation is understudied and often dismissed as a placebo or secondary effect. By systematically characterizing the human sensation evoked by transcranial alternating-current stimulation, we observed not only stimulus frequency and electrode position dependencies specific for auditory and visual sensation but also a broader presence of somatic sensation ranging from touch and vibration to pain and pressure. We found generally monotonic input-output functions at suprathreshold levels, and often multiple types of sensation occurring simultaneously in response to the same electric stimulation. We further used a recording circuit embedded in a cochlear implant to directly and objectively measure the amount of transcranial electric stimulation reaching the auditory nerve, a deep intercranial target located in the densest bone of the skull. We found an optimal configuration using an ear canal electrode and low-frequency (<300 Hz) sinusoids that delivered maximally ~1% of the transcranial current to the auditory nerve, which was sufficient to produce sound sensation even in deafened ears. Our results suggest that frequency resonance due to neuronal intrinsic electric properties need to be explored for targeted deep brain stimulation and novel brain-computer interfaces.
Collapse
Affiliation(s)
- Fan-Gang Zeng
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, California, 92697, USA.
| | - Phillip Tran
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, California, 92697, USA
| | - Matthew Richardson
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, California, 92697, USA
| | - Shuping Sun
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, California, 92697, USA
- Department of Otolaryngology - Head and Neck Surgery, The First Affiliated Hospital, Zhengzhou University, Henan, 450052, China
| | - Yuchen Xu
- Center for Hearing Research, Departments of Anatomy and Neurobiology, Biomedical Engineering, Cognitive Sciences, Otolaryngology - Head and Neck Surgery, University of California Irvine, Irvine, California, 92697, USA
- Department of Precision Instrument, Tsinghua University, Beijing, 100084, China
| |
Collapse
|
13
|
Nogueira W, Dolhopiatenko H, Schierholz I, Büchner A, Mirkovic B, Bleichner MG, Debener S. Decoding Selective Attention in Normal Hearing Listeners and Bilateral Cochlear Implant Users With Concealed Ear EEG. Front Neurosci 2019; 13:720. [PMID: 31379479 PMCID: PMC6657402 DOI: 10.3389/fnins.2019.00720] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2019] [Accepted: 06/26/2019] [Indexed: 11/29/2022] Open
Abstract
Electroencephalography (EEG) data can be used to decode an attended speech source in normal-hearing (NH) listeners using high-density EEG caps, as well as around-the-ear EEG devices. The technology may find application in identifying the target speaker in a cocktail party like scenario and steer speech enhancement algorithms in cochlear implants (CIs). However, the worse spectral resolution and the electrical artifacts introduced by a CI may limit the applicability of this approach to CI users. The goal of this study was to investigate whether selective attention can be decoded in CI users using an around-the-ear EEG system (cEEGrid). The performances of high-density cap EEG recordings and cEEGrid EEG recordings were compared in a selective attention paradigm using an envelope tracking algorithm. Speech from two audio books was presented through insert earphones to NH listeners and via direct audio cable to the CI users. 10 NH listeners and 10 bilateral CI users participated in the study. Participants were instructed to attend to one out of the two concurrent speech streams while data were recorded by a 96-channel scalp EEG and an 18-channel cEEGrid setup simultaneously. Reconstruction performance was evaluated by means of parametric correlations between the reconstructed speech and both, the envelope of the attended and the unattended speech stream. Results confirm the feasibility to decode selective attention by means of single-trial EEG data in NH and CI users using a high-density EEG. All NH listeners and 9 out of 10 CI achieved high decoding accuracies. The cEEGrid was successful in decoding selective attention in 5 out of 10 NH listeners. The same result was obtained for CI users.
Collapse
Affiliation(s)
- Waldo Nogueira
- Department of Otolaryngology, Hearing4all, Hannover Medical School, Hanover, Germany
| | - Hanna Dolhopiatenko
- Department of Otolaryngology, Hearing4all, Hannover Medical School, Hanover, Germany
| | - Irina Schierholz
- Department of Otolaryngology, Hearing4all, Hannover Medical School, Hanover, Germany
| | - Andreas Büchner
- Department of Otolaryngology, Hearing4all, Hannover Medical School, Hanover, Germany
| | - Bojana Mirkovic
- Neuropsychology Lab, Department of Psychology, Hearing4all, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Martin G Bleichner
- Neuropsychology Lab, Department of Psychology, Hearing4all, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| | - Stefan Debener
- Neuropsychology Lab, Department of Psychology, Hearing4all, Carl von Ossietzky University of Oldenburg, Oldenburg, Germany
| |
Collapse
|
14
|
Haumann S, Bauernfeind G, Teschner MJ, Schierholz I, Bleichner MG, Büchner A, Lenarz T. Epidural recordings in cochlear implant users. J Neural Eng 2019; 16:056008. [PMID: 31042688 DOI: 10.1088/1741-2552/ab1e80] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE In the long term it is desirable for CI users to control their device via brain signals. A possible strategy is the use of auditory evoked potentials (AEPs). Several studies have shown the suitability of auditory paradigms for such an approach. However, these investigations are based on non-invasive recordings. When thinking about everyday life applications, it would be more convenient to use implanted electrodes for signal acquisition. Ideally, the electrodes would be directly integrated into the CI. Further it is to be expected that invasively recorded signals have higher signal quality and are less affected by artifacts. APPROACH In this project we investigated the feasibility of implanting epidural electrodes temporarily during CI surgery and the possibility to record AEPs in the course of several days after implantation. Intraoperatively, auditory brainstem responses were recorded, whereas various kinds of AEPs were recorded postoperatively. After a few days the epidural electrodes were removed. MAIN RESULTS Data sets of ten subjects were obtained. Invasively recorded potentials were compared subjectively and objectively to clinical standard recordings using surface electrodes. Especially the cortical evoked response audiometry depicted clearer N1 waves for the epidural electrodes which were also visible at lower stimulation intensities compared to scalp electrodes. Furthermore the signal was less disturbed by artifacts. The objective quality measure (based on data sets of six patients) showed a significant better signal quality for the epidural compared to the scalp recordings. SIGNIFICANCE Altogether the approach revealed to be feasible and well tolerated by the patients. The epidural recordings showed a clearly better signal quality than the scalp recordings with AEPs being clearer recognizable. The results of the present study suggest that including epidural recording electrodes in future CI systems will improve the everyday life applicability of auditory closed loop systems for CI subjects.
Collapse
Affiliation(s)
- S Haumann
- Department of Otolaryngology, Hannover Medical School, Hannover, Germany. Cluster of Excellence 'Hearing4all', Hannover & Oldenburg, Germany
| | | | | | | | | | | | | |
Collapse
|
15
|
Mao D, Innes-Brown H, Petoe MA, Wong YT, McKay CM. Fully objective hearing threshold estimation in cochlear implant users using phase-locking value growth functions. Hear Res 2019; 377:24-33. [DOI: 10.1016/j.heares.2019.02.013] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2018] [Revised: 02/21/2019] [Accepted: 02/26/2019] [Indexed: 01/18/2023]
|
16
|
Nogueira W, Cosatti G, Schierholz I, Egger M, Mirkovic B, Buchner A. Toward Decoding Selective Attention From Single-Trial EEG Data in Cochlear Implant Users. IEEE Trans Biomed Eng 2019; 67:38-49. [PMID: 30932825 DOI: 10.1109/tbme.2019.2907638] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Previous results showed that it is possible to decode an attended speech source from EEG data via the reconstruction of the speech envelope in normal hearing (NH) listeners. However, so far it is unknown that how the performance of such a decoder is affected by the decrease in spectral resolution and the electrical artifacts introduced by a cochlear implant (CI) in users of these prostheses. NH listeners and bilateral CI users participated in the present study. Speeches from two audio books, one uttered by a male voice and one by a female voice, were presented to NH listeners and CI users. Participants were instructed to attend to one of the two speech streams presented dichotically while a 96-channel EEG was recorded. Speech envelope reconstruction from the EEG data was obtained by training decoders using a regularized least square estimation method. Decoding accuracy was defined as the percentage of accurately reconstructed trials for each subject. For NH listeners, the experiment was repeated using a vocoder to reduce spectral resolution and simulate speech perception with a CI in NH listeners. The results showed a decoding accuracy of 80.9 % using the original sound files in NH listeners. The performance dropped to 73.2 % in the vocoder condition and to 71.5 % in the group of CI users. In sum, although the accuracy drops when the spectral resolution becomes worse, the results show the feasibility to decode the attended sound source in NH listeners with a vocoder simulation, and even in CI users, albeit more training data are needed.
Collapse
|
17
|
Somers B, Verschueren E, Francart T. Neural tracking of the speech envelope in cochlear implant users. J Neural Eng 2018; 16:016003. [PMID: 30444216 DOI: 10.1088/1741-2552/aae6b9] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
OBJECTIVE When listening to speech, the brain tracks the speech envelope. It is possible to reconstruct this envelope from EEG recordings. However, in people who hear using a cochlear implant (CI), the artifacts caused by electrical stimulation of the auditory nerve contaminate the EEG. The objective of this study is to develop and validate a method for assessing the neural tracking of speech envelope in CI users. APPROACH To obtain EEG recordings free of stimulus artifacts, the electrical stimulation is periodically interrupted. During these stimulation gaps, artifact-free EEG can be sampled and used to train a linear envelope decoder. EEG recordings obtained during audible and inaudible (i.e. sub-threshold) stimulation were used to characterize the artifacts and their influence on the envelope reconstruction. MAIN RESULTS The present study demonstrates for the first time that neural tracking of the speech envelope can be measured in response to ongoing electrical stimulation. The responses were validated to be truly neural and not affected by stimulus artifact. SIGNIFICANCE Besides applications in audiology and neuroscience, the characterization and elimination of stimulus artifacts will enable future EEG studies involving continuous speech in CI users. Measures of neural tracking of the speech envelope reflect interesting properties of the listener's perception of speech, such as speech intelligibility or attentional state. Successful decoding of neural envelope tracking will open new possibilities to investigate the neural mechanisms of speech perception with a CI.
Collapse
|
18
|
Liang M, Liu J, Zhang J, Wang J, Chen Y, Cai Y, Chen L, Zheng Y. Effect of Different References on Auditory-Evoked Potentials in Children with Cochlear Implants. Front Neurosci 2017; 11:670. [PMID: 29255402 PMCID: PMC5722835 DOI: 10.3389/fnins.2017.00670] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2017] [Accepted: 11/20/2017] [Indexed: 11/24/2022] Open
Abstract
Background: Nose reference (NR), mastoid reference (MR), and montage average reference (MAR) are usually used in auditory event-related potential (AEP) studies with a recently developed reference electrode standardization technique (REST), which may reduce the reference effect. For children with cochlear implants (CIs), auditory deprivation may hinder normal development of the auditory cortex, and the reference effect may be different between CIs and a normal developing group. Methods: Thirteen right-side-CI children were recruited, comprising 7 males and 6 females, ages 2–5 years, with CI usage of ~1 year. Eleven sex- and age-matched healthy children were recruited for normal controls; 1,000 Hz pure tone evoked AEPs were recorded, and the data were re-referenced to NR, left mastoid reference (LMR, which is the opposite side of the implanted cochlear), MAR, and REST. CI artifact and P1–N1 complex (latency, amplitudes) at Fz were analyzed. Results: Confirmed P1–N1 complex could be found in Fz using NR, LMR, MAR, and REST with a 128-electrode scalp. P1 amplitude was larger using LMR than MAR and NR, while no statistically significant difference was found between NR and MAR in the CI group; REST had no significant difference with the three other references. In the control group, no statistically significant difference was found with different references. Group difference of P1 amplitude could be found when using MR, MAR, and REST. For P1 latency, no significant difference among the four references was shown, whether in the CI or control group. Group difference in P1 latency could be found in MR and MAR. N1 amplitude in LMR was significantly lower than NR and MAR in the control group. LMR, MAR, and REST could distinguish the difference in the N1 amplitude between the CI and control group. Contralateral MR or MAR was found to be better in differentiating CI children versus controls. No group difference was found for the artifact component. Conclusions: Different references for AEP studies do not affect the CI artifact. In addition, contralateral MR is preferable for P1–N1 component studies involving CI children, as well as methodology-like studies.
Collapse
Affiliation(s)
- Maojin Liang
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| | - Jiahao Liu
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| | - Junpeng Zhang
- Department of Medical Information and Engineering, Sichuan University, Chengdu, China
| | - Junbo Wang
- Department of Clinical Medicine, Sun Yat-Sen University, Guangzhou, China
| | - Yuebo Chen
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| | - Yuexin Cai
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| | - Ling Chen
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| | - Yiqing Zheng
- Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Sun Yat-Sen University, Guangzhou, China.,Department of Otolaryngology, Sun Yat-Sen Memorial Hospital, Institute of Hearing and Speech-Language Science, Sun Yat-Sen University, Guangzhou, China.,Department of Hearing and Speech Science, Xin Hua College of Sun Yat-Sen University, Guangzhou, China
| |
Collapse
|
19
|
The MMN as a viable and objective marker of auditory development in CI users. Hear Res 2017; 353:57-75. [DOI: 10.1016/j.heares.2017.07.007] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2016] [Revised: 06/16/2017] [Accepted: 07/18/2017] [Indexed: 12/31/2022]
|
20
|
Attina V, Mina F, Stahl P, Duroc Y, Veuillet E, Truy E, Thai-Van H. A New Method to Test the Efficiency of Cochlear Implant Artifacts Removal From Auditory Evoked Potentials. IEEE Trans Neural Syst Rehabil Eng 2017; 25:2453-2460. [PMID: 28692981 DOI: 10.1109/tnsre.2017.2723952] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Auditory evoked potentials are of great interest to objectively evaluate the audition in cochlear implant (CI) recipients. However, these measures are impeded by CI stimulation electrical artifacts present in the EEG. In the first part, this paper investigates the use of a hybrid model approximating CI patient data. This model gives access to both uncontaminated and denoised data, thus allowing for the evaluation of CI artifact removal methods. Here the efficiency of independent component analysis (ICA) is evaluated in the context of auditory steady-state responses (ASSRs). A dedicated experimental setup was developed to simultaneously record EEG data from a normal hearing (NH) participant and CI artifact data from a phantom equipped with a CI. Hybrid data were obtained as a linear mixture of both sources. Amplitude-modulated continuous tones were used as stimuli to elicit ASSRs. After denoising, the comparison of denoised hybrid data and original NH data showed high correlations between the two datasets, demonstrating the efficiency of ICA. In the second part, the ICA was applied to real clinical CI ASSR data. Results support the usefulness of the methodology as regards the performance evaluation of signal processing methods applied to CI patient data prior to clinical application.
Collapse
|
21
|
Somers B, Bertrand A. Removal of eye blink artifacts in wireless EEG sensor networks using reduced-bandwidth canonical correlation analysis. J Neural Eng 2016; 13:066008. [PMID: 27739407 DOI: 10.1088/1741-2560/13/6/066008] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
OBJECTIVE Chronic, 24/7 EEG monitoring requires the use of highly miniaturized EEG modules, which only measure a few EEG channels over a small area. For improved spatial coverage, a wireless EEG sensor network (WESN) can be deployed, consisting of multiple EEG modules, which interact through short-distance wireless communication. In this paper, we aim to remove eye blink artifacts in each EEG channel of a WESN by optimally exploiting the correlation between EEG signals from different modules, under stringent communication bandwidth constraints. APPROACH We apply a distributed canonical correlation analysis (CCA-)based algorithm, in which each module only transmits an optimal linear combination of its local EEG channels to the other modules. The method is validated on both synthetic and real EEG data sets, with emulated wireless transmissions. MAIN RESULTS While strongly reducing the amount of data that is shared between nodes, we demonstrate that the algorithm achieves the same eye blink artifact removal performance as the equivalent centralized CCA algorithm, which is at least as good as other state-of-the-art multi-channel algorithms that require a transmission of all channels. SIGNIFICANCE Due to their potential for extreme miniaturization, WESNs are viewed as an enabling technology for chronic EEG monitoring. However, multi-channel analysis is hampered in WESNs due to the high energy cost for wireless communication. This paper shows that multi-channel eye blink artifact removal is possible with a significantly reduced wireless communication between EEG modules.
Collapse
Affiliation(s)
- Ben Somers
- KU Leuven, Department of Neurosciences, Research Group Experimental Oto-Rhino-Laryngology, Belgium
| | | |
Collapse
|
22
|
Bertrand A. Distributed Signal Processing for Wireless EEG Sensor Networks. IEEE Trans Neural Syst Rehabil Eng 2015; 23:923-35. [DOI: 10.1109/tnsre.2015.2418351] [Citation(s) in RCA: 55] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
23
|
Scheperle RA, Abbas PJ. Relationships Among Peripheral and Central Electrophysiological Measures of Spatial and Spectral Selectivity and Speech Perception in Cochlear Implant Users. Ear Hear 2015; 36:441-53. [PMID: 25658746 PMCID: PMC4478147 DOI: 10.1097/aud.0000000000000144] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
OBJECTIVES The ability to perceive speech is related to the listener's ability to differentiate among frequencies (i.e., spectral resolution). Cochlear implant (CI) users exhibit variable speech-perception and spectral-resolution abilities, which can be attributed in part to the extent of electrode interactions at the periphery (i.e., spatial selectivity). However, electrophysiological measures of peripheral spatial selectivity have not been found to correlate with speech perception. The purpose of this study was to evaluate auditory processing at the periphery and cortex using both simple and spectrally complex stimuli to better understand the stages of neural processing underlying speech perception. The hypotheses were that (1) by more completely characterizing peripheral excitation patterns than in previous studies, significant correlations with measures of spectral selectivity and speech perception would be observed, (2) adding information about processing at a level central to the auditory nerve would account for additional variability in speech perception, and (3) responses elicited with spectrally complex stimuli would be more strongly correlated with speech perception than responses elicited with spectrally simple stimuli. DESIGN Eleven adult CI users participated. Three experimental processor programs (MAPs) were created to vary the likelihood of electrode interactions within each participant. For each MAP, a subset of 7 of 22 intracochlear electrodes was activated: adjacent (MAP 1), every other (MAP 2), or every third (MAP 3). Peripheral spatial selectivity was assessed using the electrically evoked compound action potential (ECAP) to obtain channel-interaction functions for all activated electrodes (13 functions total). Central processing was assessed by eliciting the auditory change complex with both spatial (electrode pairs) and spectral (rippled noise) stimulus changes. Speech-perception measures included vowel discrimination and the Bamford-Kowal-Bench Speech-in-Noise test. Spatial and spectral selectivity and speech perception were expected to be poorest with MAP 1 (closest electrode spacing) and best with MAP 3 (widest electrode spacing). Relationships among the electrophysiological and speech-perception measures were evaluated using mixed-model and simple linear regression analyses. RESULTS All electrophysiological measures were significantly correlated with each other and with speech scores for the mixed-model analysis, which takes into account multiple measures per person (i.e., experimental MAPs). The ECAP measures were the best predictor. In the simple linear regression analysis on MAP 3 data, only the cortical measures were significantly correlated with speech scores; spectral auditory change complex amplitude was the strongest predictor. CONCLUSIONS The results suggest that both peripheral and central electrophysiological measures of spatial and spectral selectivity provide valuable information about speech perception. Clinically, it is often desirable to optimize performance for individual CI users. These results suggest that ECAP measures may be most useful for within-subject applications when multiple measures are performed to make decisions about processor options. They also suggest that if the goal is to compare performance across individuals based on a single measure, then processing central to the auditory nerve (specifically, cortical measures of discriminability) should be considered.
Collapse
Affiliation(s)
- Rachel A. Scheperle
- Department of Communication Sciences and Disorders, University of Iowa, Iowa
City, IA, USA
| | - Paul J. Abbas
- Department of Communication Sciences and Disorders, University of Iowa, Iowa
City, IA, USA
- Otolaryngology-Head and Neck Surgery, University of Iowa, Iowa City, IA,
USA
| |
Collapse
|
24
|
Lopez Valdes A, Mc Laughlin M, Viani L, Walshe P, Smith J, Zeng FG, Reilly RB. Objective assessment of spectral ripple discrimination in cochlear implant listeners using cortical evoked responses to an oddball paradigm. PLoS One 2014; 9:e90044. [PMID: 24599314 PMCID: PMC3943794 DOI: 10.1371/journal.pone.0090044] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2013] [Accepted: 01/28/2014] [Indexed: 11/19/2022] Open
Abstract
Cochlear implants (CIs) can partially restore functional hearing in deaf individuals. However, multiple factors affect CI listener's speech perception, resulting in large performance differences. Non-speech based tests, such as spectral ripple discrimination, measure acoustic processing capabilities that are highly correlated with speech perception. Currently spectral ripple discrimination is measured using standard psychoacoustic methods, which require attentive listening and active response that can be difficult or even impossible in special patient populations. Here, a completely objective cortical evoked potential based method is developed and validated to assess spectral ripple discrimination in CI listeners. In 19 CI listeners, using an oddball paradigm, cortical evoked potential responses to standard and inverted spectrally rippled stimuli were measured. In the same subjects, psychoacoustic spectral ripple discrimination thresholds were also measured. A neural discrimination threshold was determined by systematically increasing the number of ripples per octave and determining the point at which there was no longer a significant difference between the evoked potential response to the standard and inverted stimuli. A correlation was found between the neural and the psychoacoustic discrimination thresholds (R2 = 0.60, p<0.01). This method can objectively assess CI spectral resolution performance, providing a potential tool for the evaluation and follow-up of CI listeners who have difficulty performing psychoacoustic tests, such as pediatric or new users.
Collapse
Affiliation(s)
| | - Myles Mc Laughlin
- Trinity Centre for Bioengineering, Trinity College, Dublin, Ireland
- Hearing and Speech Laboratory, University of California Irvine, Irvine, California, United States of America
| | - Laura Viani
- National Cochlear Implant Programme, Beaumont Hospital, Dublin, Ireland
| | - Peter Walshe
- National Cochlear Implant Programme, Beaumont Hospital, Dublin, Ireland
| | - Jaclyn Smith
- National Cochlear Implant Programme, Beaumont Hospital, Dublin, Ireland
| | - Fan-Gang Zeng
- Hearing and Speech Laboratory, University of California Irvine, Irvine, California, United States of America
| | | |
Collapse
|
25
|
Low-Gain, Low-Noise Integrated Neuronal Amplifier for Implantable Artifact-Reduction Recording System. JOURNAL OF LOW POWER ELECTRONICS AND APPLICATIONS 2013. [DOI: 10.3390/jlpea3030279] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
26
|
Kent AR, Grill WM. Neural origin of evoked potentials during thalamic deep brain stimulation. J Neurophysiol 2013; 110:826-43. [PMID: 23719207 DOI: 10.1152/jn.00074.2013] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023] Open
Abstract
Closed-loop deep brain stimulation (DBS) systems could provide automatic adjustment of stimulation parameters and improve outcomes in the treatment of Parkinson's disease and essential tremor. The evoked compound action potential (ECAP), generated by activated neurons near the DBS electrode, may provide a suitable feedback control signal for closed-loop DBS. The objectives of this work were to characterize the ECAP across stimulation parameters and determine the neural elements contributing to the signal. We recorded ECAPs during thalamic DBS in anesthetized cats and conducted computer simulations to calculate the ECAP of a population of thalamic neurons. The experimental and computational ECAPs were similar in shape and had characteristics that were correlated across stimulation parameters (R(2) = 0.80-0.95, P < 0.002). The ECAP signal energy increased with larger DBS amplitudes (P < 0.0001) and pulse widths (P < 0.002), and the signal energy of secondary ECAP phases was larger at 10-Hz than at 100-Hz DBS (P < 0.002). The computational model indicated that these changes resulted from a greater extent of neural activation and an increased synchronization of postsynaptic thalamocortical activity, respectively. Administration of tetrodotoxin, lidocaine, or isoflurane abolished or reduced the magnitude of the experimental and computational ECAPs, glutamate receptor antagonists 6-cyano-7-nitroquinoxaline-2,3-dione (CNQX) and D(-)-2-amino-5-phosphonopentanoic acid (APV) reduced secondary ECAP phases by decreasing postsynaptic excitation, and the GABAA receptor agonist muscimol increased the latency of the secondary phases by augmenting postsynaptic hyperpolarization. This study demonstrates that the ECAP provides information about the type and extent of neural activation generated during DBS, and the ECAP may serve as a feedback control signal for closed-loop DBS.
Collapse
Affiliation(s)
- Alexander R Kent
- Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708-0281, USA
| | | |
Collapse
|
27
|
Mc Laughlin M, Lopez Valdes A, Reilly RB, Zeng FG. Cochlear implant artifact attenuation in late auditory evoked potentials: a single channel approach. Hear Res 2013; 302:84-95. [PMID: 23727626 DOI: 10.1016/j.heares.2013.05.006] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/10/2012] [Revised: 05/07/2013] [Accepted: 05/12/2013] [Indexed: 10/26/2022]
Abstract
Recent evidence suggests that late auditory evoked potentials (LAEP) provide a useful objective metric of performance in cochlear implant (CI) subjects. However, the CI produces a large electrical artifact that contaminates LAEP recordings and confounds their interpretation. Independent component analysis (ICA) has been used in combination with multi-channel recordings to effectively remove the artifact. The applicability of the ICA approach is limited when only single channel data are needed or available, as is often the case in both clinical and research settings. Here we developed a single-channel, high sample rate (125 kHz), and high bandwidth (0-100 kHz) acquisition system to reduce the CI stimulation artifact. We identified two different artifacts in the recording: 1) a high frequency artifact reflecting the stimulation pulse rate, and 2) a direct current (DC, or pedestal) artifact that showed a non-linear time varying relationship to pulse amplitude. This relationship was well described by a bivariate polynomial. The high frequency artifact was completely attenuated by a 35 Hz low-pass filter for all subjects (n = 22). The DC artifact could be caused by an impedance mismatch. For 27% of subjects tested, no DC artifact was observed when electrode impedances were balanced to within 1 kΩ. For the remaining 73% of subjects, the pulse amplitude was used to estimate and then attenuate the DC artifact. Where measurements of pulse amplitude were not available (as with standard low sample rate systems), the DC artifact could be estimated from the stimulus envelope. The present artifact removal approach allows accurate measurement of LAEPs from CI subjects from single channel recordings, increasing their feasibility and utility as an accessible objective measure of CI function.
Collapse
Affiliation(s)
- Myles Mc Laughlin
- Hearing and Speech Laboratory, University of California Irvine, Irvine, CA 92697, USA.
| | | | | | | |
Collapse
|