Gonzalez-Montoro A, Pavón N, Barberá J, Cuarella N, González AJ, Jiménez-Serrano S, Lucero A, Moliner L, Sánchez D, Vidal K, Benlloch JM. Design and proof of concept of a double-panel TOF-PET system. EJNMMI Phys 2024; 11:73. [PMID: 39174856 PMCID: PMC11341523 DOI: 10.1186/s40658-024-00674-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2024] [Accepted: 08/05/2024] [Indexed: 08/24/2024] Open
Abstract
OBJECTIVE Positron Emission Tomography (PET) is a well-known imaging technology for the diagnosis, treatment, and monitoring of several diseases. Most PET scanners use a Ring-Shaped Detector Configuration (RSDC), which helps obtain homogeneous image quality but are restricted to an invariable Field-of-View (FOV), scarce spatial resolution, and low sensitivity. Alternatively, few PET systems use Open Detector Configurations (ODC) to permit an accessible FOV adaptable to different target sizes, thus optimizing sensitivity. Yet, to compensate the lack of angular coverage in ODC-PET, developing a detector with high-timing performance is mandatory to enable Time-of-Flight (TOF) techniques during reconstruction. The main goal of this work is to provide a proof of concept PET scanner appropriate for constructing the new generation of ODC-PET suitable for biopsy guidance and clinical intervention during acquisition. The designed detector has to be compact and robust, and its requirements in terms of performance are spatial and time resolutions < 2 mm and < 200 ps, respectively. METHODS The present work includes a simulation study of an ODC-PET based on 2-panels with variable distance. The image quality (IQ) and Derenzo phantoms have been simulated and evaluated. The phantom simulations have also been performed using a ring-shaped PET for comparison purposes of the ODC approach with conventional systems. Then, an experimental evaluation of a prototype detector that has been designed following the simulation results is presented. This study focused on tuning the ASIC parameters and evaluating the scintillator surface treatment (ESR and TiO2), and configuration that yields the best Coincidence Time Resolution (CTR). Moreover, the scalability of the prototype to a module of 64 × 64mm2 and its preliminary evaluation regarding pixel identification are provided. RESULTS The simulation results reported sensitivity (%) values at the center of the FOV of 1.96, 1.63, and 1.18 for panel distances of 200, 250, and 300 mm, respectively. The IQ reconstructed image reported good uniformity (87%) and optimal CRC values, and the Derenzo phantom reconstruction suggests a system resolution of 1.6-2 mm. The experimental results demonstrate that using TiO2 coating yielded better detector performance than ESR. Acquired data was filtered by applying an energy window of ± 30% at the photopeak level. After filtering, best CTR of 230 ± 2 ps was achieved for an 8 × 8 LYSO pixel block with 2 × 2 × 12mm3 each. The detector performance remained constant after scaling-up the prototype to a module of 64 × 64mm2, and the flood map demonstrates the module's capabilities to distinguish the small pixels; thus, a spatial resolution < 2 mm (pixel size) is achieved. CONCLUSIONS The simulated results of this biplanar scanner show high performance in terms of image quality and sensitivity. These results are comparable to state-of-the-art PET technology and, demonstrate that including TOF information minimizes the image artifacts due to the lack of angular projections. The experimental results concluded that using TiO2 coating provide the best performance. The results suggest that this scanner may be suitable for organ study, breast, prostate, or cardiac applications, with good uniformity and CRC.
Collapse
Affiliation(s)
- Andrea Gonzalez-Montoro
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain.
| | - Noriel Pavón
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Julio Barberá
- Oncovision, C/Jerónimo de Monsoriu, 92 Bajo, Valencia, Spain
| | - Neus Cuarella
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Antonio J González
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Santiago Jiménez-Serrano
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Alejandro Lucero
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Laura Moliner
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - David Sánchez
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - Koldo Vidal
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| | - José M Benlloch
- Centro Mixto CSIC - UPV, Instituto de Instrumentación Para Imagen Molecular, Camino de Vera S/N, 46022, Valencia, Spain
| |
Collapse
|
2
|
Arabi H, Manesh AS, Zaidi H. Innovations in dedicated PET instrumentation: from the operating room to specimen imaging. Phys Med Biol 2024; 69:11TR03. [PMID: 38744305 DOI: 10.1088/1361-6560/ad4b92] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2024] [Accepted: 05/14/2024] [Indexed: 05/16/2024]
Abstract
This review casts a spotlight on intraoperative positron emission tomography (PET) scanners and the distinctive challenges they confront. Specifically, these systems contend with the necessity of partial coverage geometry, essential for ensuring adequate access to the patient. This inherently leans them towards limited-angle PET imaging, bringing along its array of reconstruction and geometrical sensitivity challenges. Compounding this, the need for real-time imaging in navigation systems mandates rapid acquisition and reconstruction times. For these systems, the emphasis is on dependable PET image reconstruction (without significant artefacts) while rapid processing takes precedence over the spatial resolution of the system. In contrast, specimen PET imagers are unburdened by the geometrical sensitivity challenges, thanks to their ability to leverage full coverage PET imaging geometries. For these devices, the focus shifts: high spatial resolution imaging takes precedence over rapid image reconstruction. This review concurrently probes into the technical complexities of both intraoperative and specimen PET imaging, shedding light on their recent designs, inherent challenges, and technological advancements.
Collapse
Affiliation(s)
- Hossein Arabi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Abdollah Saberi Manesh
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
| | - Habib Zaidi
- Division of Nuclear Medicine and Molecular Imaging, Geneva University Hospital, CH-1211 Geneva 4, Switzerland
- Department of Nuclear Medicine and Molecular Imaging, University of Groningen, University Medical Center Groningen, 9700 RB Groningen, The Netherlands
- Department of Nuclear Medicine, University of Southern Denmark, 500 Odense, Denmark
- University Research and Innovation Center, Óbuda University, Budapest, Hungary
| |
Collapse
|
3
|
Llosá G, Rafecas M. Hybrid PET/Compton-camera imaging: an imager for the next generation. EUROPEAN PHYSICAL JOURNAL PLUS 2023; 138:214. [PMID: 36911362 PMCID: PMC9990967 DOI: 10.1140/epjp/s13360-023-03805-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/30/2022] [Accepted: 02/11/2023] [Indexed: 06/18/2023]
Abstract
Compton cameras can offer advantages over gamma cameras for some applications, since they are well suited for multitracer imaging and for imaging high-energy radiotracers, such as those employed in radionuclide therapy. While in conventional clinical settings state-of-the-art Compton cameras cannot compete with well-established methods such as PET and SPECT, there are specific scenarios in which they can constitute an advantageous alternative. The combination of PET and Compton imaging can benefit from the improved resolution and sensitivity of current PET technology and, at the same time, overcome PET limitations in the use of multiple radiotracers. Such a system can provide simultaneous assessment of different radiotracers under identical conditions and reduce errors associated with physical factors that can change between acquisitions. Advances are being made both in instrumentation developments combining PET and Compton cameras for multimodal or three-gamma imaging systems, and in image reconstruction, addressing the challenges imposed by the combination of the two modalities or the new techniques. This review article summarizes the advances made in Compton cameras for medical imaging and their combination with PET.
Collapse
Affiliation(s)
- Gabriela Llosá
- Instituto de Física Corpuscular (IFIC), CSIC-UV, Catedrático Beltrán, 2., 46980 Paterna, Valencia, Spain
| | - Magdalena Rafecas
- Institute of Medical Engineering (IMT), Universität zu Lübeck, Ratzeburger Allee 160, 23562 Lübeck, Germany
| |
Collapse
|
4
|
Vergara M, Rezaei A, Schramm G, Rodriguez-Alvarez MJ, Benlloch Baviera JM, Nuyts J. 2D feasibility study of joint reconstruction of attenuation and activity in limited angle TOF-PET. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:712-722. [PMID: 34541435 PMCID: PMC8445242 DOI: 10.1109/trpms.2021.3079462] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Several research groups are studying organ-dedicated limited angle positron emission tomography (PET) systems to optimize performance-cost ratio, sensitivity, access to the patient and/or flexibility. Often open systems are considered, typically consisting of two detector panels of various sizes. Such systems provide incomplete sampling due to limited angular coverage and/or truncation, which leads to artefacts in the reconstructed activity images. In addition, these organ-dedicated PET systems are usually stand-alone systems, and as a result, no attenuation information can be obtained from anatomical images acquired in the same imaging session. It has been shown that the use of time-of-flight information reduces incomplete data artefacts and enables the joint estimation of the activity and the attenuation factors. In this work, we explore with simple 2D simulations the performance and stability of a joint reconstruction algorithm, for imaging with a limited angle PET system. The reconstruction is based on the so-called MLACF (Maximum Likelihood Attenuation Correction Factors) algorithm and uses linear attenuation coefficients in a known-tissue-class region to obtain absolute quantification. Different panel sizes and different time-of-flight (TOF) resolutions are considered. The noise propagation is compared to that of MLEM reconstruction with exact attenuation correction (AC) for the same PET system. The results show that with good TOF resolution, images of good visual quality can be obtained. If also a good scatter correction can be implemented, quantitative PET imaging will be possible. Further research, in particular on scatter correction, is required.
Collapse
Affiliation(s)
- Marina Vergara
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, Belgium and Instituto de Instrumentación para Imagen Molecular Centro Mixto CSIC—Universitat Politècnica de València, Valencia, Spain
| | - Ahmadreza Rezaei
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, Belgium
| | - Georg Schramm
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, Belgium
| | - Maria Jose Rodriguez-Alvarez
- Instituto de Instrumentación para Imagen Molecular Centro Mixto CSIC—Universitat Politècnica de València, Valencia, Spain
| | - Jose Maria Benlloch Baviera
- Instituto de Instrumentación para Imagen Molecular Centro Mixto CSIC—Universitat Politècnica de València, Valencia, Spain
| | - Johan Nuyts
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, Belgium
| |
Collapse
|
5
|
Xu H, Wang H, Xu F, Cheng R, Zhang B, Fang L, Xie Q, Xiao P. Neural-Network-Based Energy Calculation for Multivoltage Threshold Sampling. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2020. [DOI: 10.1109/trpms.2019.2960129] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
6
|
Liu Z, Lan X. Microfluidic radiobioassays: a radiometric detection tool for understanding cellular physiology and pharmacokinetics. LAB ON A CHIP 2019; 19:2315-2339. [PMID: 31222194 DOI: 10.1039/c9lc00159j] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
The investigation of molecular uptake and its kinetics in cells is valuable for understanding the cellular physiological status, the observation of drug interventions, and the development of imaging agents and pharmaceuticals. Microfluidic radiobioassays, or microfluidic radiometric bioassays, constitute a radiometric imaging-on-a-chip technology for the assay of biological samples using radiotracers. From 2006 to date, microfluidic radiobioassays have shown advantages in many applications, including radiotracer characterization, enzyme activity radiobioassays, fast drug evaluation, single-cell imaging, facilitation of dynamic positron emission tomography (PET) imaging, and cellular pharmacokinetics (PK)/pharmacodynamics (PD) studies. These advantages lie in the minimized and integrated detection scheme, allowing real-time tracking of dynamic uptake, high sensitivity radiotracer imaging, and quantitative interpretation of imaging results. In this review, the basics of radiotracers, various radiometric detection methods, and applications of microfluidic radiobioassays will be introduced and summarized, and the potential applications and future directions of microfluidic radiobioassays will be forecasted.
Collapse
Affiliation(s)
- Zhen Liu
- Department of Nuclear Medicine, Wuhan Union Hospital, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, No. 1277 Jiefang Ave, Wuhan, Hubei Province 430022, China.
| | | |
Collapse
|
7
|
New Digital Plug and Imaging Sensor for a Proton Therapy Monitoring System Based on Positron Emission Tomography. SENSORS 2018; 18:s18093006. [PMID: 30241279 PMCID: PMC6164641 DOI: 10.3390/s18093006] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2018] [Revised: 09/01/2018] [Accepted: 09/02/2018] [Indexed: 11/17/2022]
Abstract
One of the most challenging areas of sensor development for nuclear medicine is the design of proton therapy monitoring systems. Sensors are operated in a high detection rate regime in beam-on conditions. We realized a prototype of a monitoring system for proton therapy based on the technique of positron emission tomography. We used the Plug and Imaging (P&I) technology in this application. This sensing system includes LYSO/silicon photomultiplier (SiPM) detection elements, fast digital multi voltage threshold (MVT) readout electronics and dedicated image reconstruction algorithms. In this paper, we show that the P&I sensor system has a uniform response and is controllable in the experimental conditions of the proton therapy room. The prototype of PET monitoring device based on the P&I sensor system has an intrinsic experimental spatial resolution of approximately 3 mm (FWHM), obtained operating the prototype both during the beam irradiation and right after it. The count-rate performance of the P&I sensor approaches 5 Mcps and allows the collection of relevant statistics for the nuclide analysis. The measurement of both the half life and the relative abundance of the positron emitters generated in the target volume through irradiation of 1010 protons in approximately 15 s is performed with 0.5% and 5% accuracy, respectively.
Collapse
|
8
|
Gonzalez AJ, Sanchez F, Benlloch JM. Organ-Dedicated Molecular Imaging Systems. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2018. [DOI: 10.1109/trpms.2018.2846745] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|