1
|
Fang J, Zeng F, Liu H. Signal separation of simultaneous dual-tracer PET imaging based on global spatial information and channel attention. EJNMMI Phys 2024; 11:47. [PMID: 38809438 PMCID: PMC11136940 DOI: 10.1186/s40658-024-00649-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2023] [Accepted: 05/15/2024] [Indexed: 05/30/2024] Open
Abstract
BACKGROUND Simultaneous dual-tracer positron emission tomography (PET) imaging efficiently provides more complete information for disease diagnosis. The signal separation has long been a challenge of dual-tracer PET imaging. To predict the single-tracer images, we proposed a separation network based on global spatial information and channel attention, and connected it to FBP-Net to form the FBPnet-Sep model. RESULTS Experiments using simulated dynamic PET data were conducted to: (1) compare the proposed FBPnet-Sep model to Sep-FBPnet model and currently existing Multi-task CNN, (2) verify the effectiveness of modules incorporated in FBPnet-Sep model, (3) investigate the generalization of FBPnet-Sep model to low-dose data, and (4) investigate the application of FBPnet-Sep model to multiple tracer combinations with decay corrections. Compared to the Sep-FBPnet model and Multi-task CNN, the FBPnet-Sep model reconstructed single-tracer images with higher structural similarity, peak signal-to-noise ratio and lower mean squared error, and reconstructed time-activity curves with lower bias and variation in most regions. Excluding the Inception or channel attention module resulted in degraded image qualities. The FBPnet-Sep model showed acceptable performance when applied to low-dose data. Additionally, it could deal with multiple tracer combinations. The qualities of predicted images, as well as the accuracy of derived time-activity curves and macro-parameters were slightly improved by incorporating a decay correction module. CONCLUSIONS The proposed FBPnet-Sep model was considered a potential method for the reconstruction and signal separation of simultaneous dual-tracer PET imaging.
Collapse
Affiliation(s)
- Jingwan Fang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Fuzhen Zeng
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Huafeng Liu
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China.
| |
Collapse
|
2
|
Sun Y, Cheng Z, Qiu J, Lu W. Performance and application of the total-body PET/CT scanner: a literature review. EJNMMI Res 2024; 14:38. [PMID: 38607510 PMCID: PMC11014840 DOI: 10.1186/s13550-023-01059-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2023] [Accepted: 12/14/2023] [Indexed: 04/13/2024] Open
Abstract
BACKGROUND The total-body positron emission tomography/computed tomography (PET/CT) system, with a long axial field of view, represents the state-of-the-art PET imaging technique. Recently, the total-body PET/CT system has been commercially available. The total-body PET/CT system enables high-resolution whole-body imaging, even under extreme conditions such as ultra-low dose, extremely fast imaging speed, delayed imaging more than 10 h after tracer injection, and total-body dynamic scan. The total-body PET/CT system provides a real-time picture of the tracers of all organs across the body, which not only helps to explain normal human physiological process, but also facilitates the comprehensive assessment of systemic diseases. In addition, the total-body PET/CT system may play critical roles in other medical fields, including cancer imaging, drug development and immunology. MAIN BODY Therefore, it is of significance to summarize the existing studies of the total-body PET/CT systems and point out its future direction. This review collected research literatures from the PubMed database since the advent of commercially available total-body PET/CT systems to the present, and was divided into the following sections: Firstly, a brief introduction to the total-body PET/CT system was presented, followed by a summary of the literature on the performance evaluation of the total-body PET/CT. Then, the research and clinical applications of the total-body PET/CT were discussed. Fourthly, deep learning studies based on total-body PET imaging was reviewed. At last, the shortcomings of existing research and future directions for the total-body PET/CT were discussed. CONCLUSION Due to its technical advantages, the total-body PET/CT system is bound to play a greater role in clinical practice in the future.
Collapse
Affiliation(s)
- Yuanyuan Sun
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China
| | - Zhaoping Cheng
- Department of PET-CT, The First Affiliated Hospital of Shandong First Medical University, Shandong Provincial Qianfoshan Hospital Affiliated to Shandong University, Jinan, 250014, China
| | - Jianfeng Qiu
- Department of Radiology, Shandong First Medical University & Shandong Academy of Medical Sciences, Taian, 271016, China
| | - Weizhao Lu
- Department of Radiology, The Second Affiliated Hospital of Shandong First Medical University, No. 366 Taishan Street, Taian, 271000, China.
| |
Collapse
|
3
|
Miederer I, Shi K, Wendler T. Machine learning methods for tracer kinetic modelling. Nuklearmedizin 2023; 62:370-378. [PMID: 37820696 DOI: 10.1055/a-2179-5818] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/13/2023]
Abstract
Tracer kinetic modelling based on dynamic PET is an important field of Nuclear Medicine for quantitative functional imaging. Yet, its implementation in clinical routine has been constrained by its complexity and computational costs. Machine learning poses an opportunity to improve modelling processes in terms of arterial input function prediction, the prediction of kinetic modelling parameters and model selection in both clinical and preclinical studies while reducing processing time. Moreover, it can help improving kinetic modelling data used in downstream tasks such as tumor detection. In this review, we introduce the basics of tracer kinetic modelling and present a literature review of original works and conference papers using machine learning methods in this field.
Collapse
Affiliation(s)
- Isabelle Miederer
- Department of Nuclear Medicine, University Medical Center of the Johannes Gutenberg University Mainz, Mainz, Germany
| | - Kuangyu Shi
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, Bern, Switzerland
- Chair for Computer-Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching near Munich, Germany
| | - Thomas Wendler
- Chair for Computer-Aided Medical Procedures and Augmented Reality, Technical University of Munich, Garching near Munich, Germany
- Department of diagnostic and interventional Radiology and Neuroradiology, University Hospital Augsburg, Augsburg, Germany
| |
Collapse
|
4
|
Cavalcanti YC, Oberlin T, Ferraris V, Dobigeon N, Ribeiro M, Tauber C. Compartment model-based nonlinear unmixing for kinetic analysis of dynamic PET images. Med Image Anal 2023; 84:102689. [PMID: 36502604 DOI: 10.1016/j.media.2022.102689] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 09/14/2022] [Accepted: 11/08/2022] [Indexed: 11/23/2022]
Abstract
When no arterial input function is available, quantification of dynamic PET images requires a previous step devoted to the extraction of a reference time-activity curve (TAC). Factor analysis is often applied for this purpose. This paper introduces a novel approach that conducts a new kind of nonlinear factor analysis relying on a compartment model, and computes the kinetic parameters of specific binding tissues jointly. To this end, it capitalizes on data-driven parametric imaging methods to provide a physical description of the underlying PET data, directly relating the specific binding with the kinetics of the non-specific binding in the corresponding tissues. This characterization is introduced into the factor analysis formulation to yield a novel nonlinear unmixing model designed for PET image analysis. This model also explicitly introduces global kinetic parameters that allow for a direct estimation of a binding potential that represents the ratio at equilibrium of specifically bound radioligand to the concentration of nondisplaceable radioligand in each non-specific binding tissue. The performance of the method is evaluated on synthetic and real data to demonstrate its potential interest.
Collapse
Affiliation(s)
| | | | - Vinicius Ferraris
- University of Toulouse, IRIT/INP-ENSEEIHT, 31071, Toulouse Cedex 7, France.
| | - Nicolas Dobigeon
- University of Toulouse, IRIT/INP-ENSEEIHT, 31071, Toulouse Cedex 7, France; Institut Universitaire de France (IUF), France.
| | - Maria Ribeiro
- UMRS Inserm U930 - Université de Tours, 37032 Tours, France.
| | - Clovis Tauber
- UMRS Inserm U930 - Université de Tours, 37032 Tours, France.
| |
Collapse
|
5
|
Zeng F, Fang J, Muhashi A, Liu H. Direct reconstruction for simultaneous dual-tracer PET imaging based on multi-task learning. EJNMMI Res 2023; 13:7. [PMID: 36719532 PMCID: PMC9889598 DOI: 10.1186/s13550-023-00955-w] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2022] [Accepted: 01/17/2023] [Indexed: 02/01/2023] Open
Abstract
BACKGROUND Simultaneous dual-tracer positron emission tomography (PET) imaging can observe two molecular targets in a single scan, which is conducive to disease diagnosis and tracking. Since the signals emitted by different tracers are the same, it is crucial to separate each single tracer from the mixed signals. The current study proposed a novel deep learning-based method to reconstruct single-tracer activity distributions from the dual-tracer sinogram. METHODS We proposed the Multi-task CNN, a three-dimensional convolutional neural network (CNN) based on a framework of multi-task learning. One common encoder extracted features from the dual-tracer dynamic sinogram, followed by two distinct and parallel decoders which reconstructed the single-tracer dynamic images of two tracers separately. The model was evaluated by mean squared error (MSE), multiscale structural similarity (MS-SSIM) index and peak signal-to-noise ratio (PSNR) on simulated data and real animal data, and compared to the filtered back-projection method based on deep learning (FBP-CNN). RESULTS In the simulation experiments, the Multi-task CNN reconstructed single-tracer images with lower MSE, higher MS-SSIM and PSNR than FBP-CNN, and was more robust to the changes in individual difference, tracer combination and scanning protocol. In the experiment of rats with an orthotopic xenograft glioma model, the Multi-task CNN reconstructions also showed higher qualities than FBP-CNN reconstructions. CONCLUSIONS The proposed Multi-task CNN could effectively reconstruct the dynamic activity images of two single tracers from the dual-tracer dynamic sinogram, which was potential in the direct reconstruction for real simultaneous dual-tracer PET imaging data in future.
Collapse
Affiliation(s)
- Fuzhen Zeng
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Jingwan Fang
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Amanjule Muhashi
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China
| | - Huafeng Liu
- State Key Laboratory of Modern Optical Instrumentation, College of Optical Science and Engineering, Zhejiang University, Hangzhou, China.
| |
Collapse
|
6
|
Pain CD, Egan GF, Chen Z. Deep learning-based image reconstruction and post-processing methods in positron emission tomography for low-dose imaging and resolution enhancement. Eur J Nucl Med Mol Imaging 2022; 49:3098-3118. [PMID: 35312031 PMCID: PMC9250483 DOI: 10.1007/s00259-022-05746-4] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2021] [Accepted: 02/25/2022] [Indexed: 12/21/2022]
Abstract
Image processing plays a crucial role in maximising diagnostic quality of positron emission tomography (PET) images. Recently, deep learning methods developed across many fields have shown tremendous potential when applied to medical image enhancement, resulting in a rich and rapidly advancing literature surrounding this subject. This review encapsulates methods for integrating deep learning into PET image reconstruction and post-processing for low-dose imaging and resolution enhancement. A brief introduction to conventional image processing techniques in PET is firstly presented. We then review methods which integrate deep learning into the image reconstruction framework as either deep learning-based regularisation or as a fully data-driven mapping from measured signal to images. Deep learning-based post-processing methods for low-dose imaging, temporal resolution enhancement and spatial resolution enhancement are also reviewed. Finally, the challenges associated with applying deep learning to enhance PET images in the clinical setting are discussed and future research directions to address these challenges are presented.
Collapse
Affiliation(s)
- Cameron Dennis Pain
- Monash Biomedical Imaging, Monash University, Melbourne, Australia.
- Department of Electrical and Computer Systems Engineering, Monash University, Melbourne, Australia.
| | - Gary F Egan
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
- Turner Institute for Brain and Mental Health, Monash University, Melbourne, Australia
| | - Zhaolin Chen
- Monash Biomedical Imaging, Monash University, Melbourne, Australia
- Department of Data Science and AI, Monash University, Melbourne, Australia
| |
Collapse
|
7
|
Wang Y, Li E, Cherry SR, Wang G. Total-Body PET Kinetic Modeling and Potential Opportunities Using Deep Learning. PET Clin 2021; 16:613-625. [PMID: 34353745 PMCID: PMC8453049 DOI: 10.1016/j.cpet.2021.06.009] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The uEXPLORER total-body PET/CT system provides a very high level of detection sensitivity and simultaneous coverage of the entire body for dynamic imaging for quantification of tracer kinetics. This article describes the fundamentals and potential benefits of total-body kinetic modeling and parametric imaging focusing on the noninvasive derivation of blood input function, multiparametric imaging, and high-temporal resolution kinetic modeling. Along with its attractive properties, total-body kinetic modeling also brings significant challenges, such as the large scale of total-body dynamic PET data, the need for organ and tissue appropriate input functions and kinetic models, and total-body motion correction. These challenges, and the opportunities using deep learning, are discussed.
Collapse
Affiliation(s)
- Yiran Wang
- Department of Biomedical Engineering, University of California, 451 E. Health Sciences Drive, Davis, CA 95616, USA; Department of Radiology, University of California Davis Medical Center, Ambulatory Care Center, Building Suite 3100, 4860 Y Street, Sacramento, CA 95817, USA
| | - Elizabeth Li
- Department of Biomedical Engineering, University of California, 451 E. Health Sciences Drive, Davis, CA 95616, USA
| | - Simon R Cherry
- Department of Biomedical Engineering, University of California, 451 E. Health Sciences Drive, Davis, CA 95616, USA; Department of Radiology, University of California Davis Medical Center, Ambulatory Care Center, Building Suite 3100, 4860 Y Street, Sacramento, CA 95817, USA
| | - Guobao Wang
- Department of Radiology, University of California Davis Medical Center, Ambulatory Care Center, Building Suite 3100, 4860 Y Street, Sacramento, CA 95817, USA.
| |
Collapse
|
8
|
Wu W, Yu H, Chen P, Luo F, Liu F, Wang Q, Zhu Y, Zhang Y, Feng J, Yu H. Dictionary learning based image-domain material decomposition for spectral CT. Phys Med Biol 2020; 65:245006. [PMID: 32693395 DOI: 10.1088/1361-6560/aba7ce] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
The potential huge advantage of spectral computed tomography (CT) is that it can provide accurate material identification and quantitative tissue information by material decomposition. However, material decomposition is a typical inverse problem, where the noise can be magnified. To address this issue, we develop a dictionary learning based image-domain material decomposition (DLIMD) method for spectral CT to achieve accurate material components with better image quality. Specifically, a set of image patches are extracted from the mode-1 unfolding of normalized material images decomposed by direct inversion to train a unified dictionary using the K-SVD technique. Then, the DLIMD model is established to explore the redundant similarities of the material images, where the split-Bregman is employed to optimize the model. Finally, more constraints (i.e. volume conservation and the bounds of each pixel within material maps) are integrated into the DLIMD model. Numerical phantom, physical phantom and preclinical experiments are performed to evaluate the performance of the proposed DLIMD in material decomposition accuracy, material image edge preservation and feature recovery.
Collapse
Affiliation(s)
- Weiwen Wu
- Key Lab of Optoelectronic Technology and Systems, Ministry of Education, Chongqing University, Chongqing 400044, People's Republic of China
| | | | | | | | | | | | | | | | | | | |
Collapse
|