1
|
Correia PMM, Cruzeiro B, Dias J, Encarnação PMCC, Ribeiro FM, Rodrigues CA, Silva ALM. Precise positioning of gamma ray interactions in multiplexed pixelated scintillators using artificial neural networks. Biomed Phys Eng Express 2024; 10:045038. [PMID: 38779912 DOI: 10.1088/2057-1976/ad4f73] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2024] [Accepted: 05/22/2024] [Indexed: 05/25/2024]
Abstract
Introduction. The positioning ofγray interactions in positron emission tomography (PET) detectors is commonly made through the evaluation of the Anger logic flood histograms. machine learning techniques, leveraging features extracted from signal waveform, have demonstrated successful applications in addressing various challenges in PET instrumentation.Aim. This paper evaluates the use of artificial neural networks (NN) forγray interaction positioning in pixelated scintillators coupled to a multiplexed array of silicon photomultipliers (SiPM).Methods. An array of 16 Cerium doped Lutetium-based (LYSO) crystal pixels (cross-section 2 × 2 mm2) coupled to 16 SiPM (S13360-1350) were used for the experimental setup. Data from each of the 16 LYSO pixels was recorded, a total of 160000 events. The detectors were irradiated by 511 keV annihilationγrays from a Sodium-22 (22Na) source. Another LYSO crystal was used for electronic collimation. Features extracted from the signal waveform were used to train the model. Two models were tested: i) single multiple-class neural network (mcNN), with 16 possible outputs followed by a softmax and ii) 16 binary classification neural networks (bNN), each one specialized in identifying events occurred in each position.Results. Both NN models showed a mean positioning accuracy above 85% on the evaluation dataset, although the mcNN is faster to train.DiscussionThe method's accuracy is affected by the introduction of misclassified events that interacted in the neighbour's crystals and were misclassified during the dataset acquisition. Electronic collimation reduces this effect, however results could be improved using a more complex acquisition setup, such as a light-sharing configuration.ConclusionsThe methods comparison showed that mcNN and bNN can surpass the Anger logic, showing the feasibility of using these models in positioning procedures of future multiplexed detector systems in a linear configuration.
Collapse
Affiliation(s)
- P M M Correia
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| | - B Cruzeiro
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| | - J Dias
- Faculdade de Economia, CeBER, Universidade de Coimbra, Av. Dias da Silva, 165, 3004-512 Coimbra, Portugal
- INESC-Coimbra, Universidade de Coimbra, Rua Sílvio Lima, Pólo II, 3030-290 Coimbra, Portugal
| | - P M C C Encarnação
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| | - F M Ribeiro
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| | - C A Rodrigues
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| | - A L M Silva
- Institute for Nanostructures, Nanomodelling and Nanofabrication (i3N), University of Aveiro, Campus Universitário de Santiago, 3810-193, Aveiro, Portugal
| |
Collapse
|
2
|
Kuhl Y, Mueller F, Naunheim S, Bovelett M, Lambertus J, Schug D, Weissler B, Gegenmantel E, Gebhardt P, Schulz V. A finely segmented semi-monolithic detector tailored for high-resolution PET. Med Phys 2024; 51:3421-3436. [PMID: 38214395 DOI: 10.1002/mp.16928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 12/20/2023] [Accepted: 12/20/2023] [Indexed: 01/13/2024] Open
Abstract
BACKGROUND Preclinical research and organ-dedicated applications use and require high (spatial-)resolution positron emission tomography (PET) detectors to visualize small structures (early) and understand biological processes at a finer level of detail. Researchers seeking to improve detector and image spatial resolution have explored various detector designs. Current commercial high-resolution systems often employ finely pixelated or monolithic scintillators, each with its limitations. PURPOSE We present a semi-monolithic detector, tailored for high-resolution PET applications with a spatial resolution in the range of 1 mm or better, merging concepts of monolithic and pixelated crystals. The detector features LYSO slabs measuring (24 × 10 × 1) mm3, coupled to a 12 × 12 readout channel photosensor with 4 mm pitch. The slabs are grouped in two arrays of 44 slabs each to achieve a higher optical photon density despite the fine segmentation. METHODS We employ a fan beam collimator for fast calibration to train machine-learning-based positioning models for all three dimensions, including slab identification and depth-of-interaction (DOI), utilizing gradient tree boosting (GTB). The data for all dimensions was acquired in less than 2 h. Energy calculation was based on a position-dependent energy calibration. Using an analytical timing calibration, time skews were corrected for coincidence timing resolution (CTR) estimation. RESULTS Leveraging machine-learning-based calibration in all three dimensions, we achieved high detector spatial resolution: down to 1.18 mm full width at half maximum (FWHM) detector spatial resolution and 0.75 mm mean absolute error (MAE) in the planar-monolithic direction, and 2.14 mm FWHM and 1.03 mm MAE for DOI at an energy window of (435-585) keV. Correct slab interaction identification in planar-segmented direction exceeded 80%, alongside an energy resolution of 12.7% and a CTR of 450 ps FWHM. CONCLUSIONS The introduced finely segmented, high-resolution slab detector demonstrates appealing performance characteristics suitable for high-resolution PET applications. The current benchtop-based detector calibration routine allows these detectors to be used in PET systems.
Collapse
Affiliation(s)
- Yannick Kuhl
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Florian Mueller
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Stephan Naunheim
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Matthias Bovelett
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Janko Lambertus
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - David Schug
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Bjoern Weissler
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | | | - Pierre Gebhardt
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Volkmar Schulz
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
- Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
- Physics Institute III B, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
3
|
Zeng X, Zhang Z, Li D, Huang X, Wang Z, Wang Y, Zhou W, Wang P, Zhu M, Wei Q, Gong H, Wei L. Evaluation of monolithic crystal detector with dual-ended readout utilizing multiplexing method. Phys Med Biol 2024; 69:085003. [PMID: 38484392 DOI: 10.1088/1361-6560/ad3417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2023] [Accepted: 03/14/2024] [Indexed: 04/04/2024]
Abstract
Objective.Monolithic crystal detectors are increasingly being applied in positron emission tomography (PET) devices owing to their excellent depth-of-interaction (DOI) resolution capabilities and high detection efficiency. In this study, we constructed and evaluated a dual-ended readout monolithic crystal detector based on a multiplexing method.Approach.We employed two 12 × 12 silicon photomultiplier (SiPM) arrays for readout, and the signals from the 12 × 12 array were merged into 12 X and 12 Y channels using channel multiplexing. In 2D reconstruction, three methods based on the centre of gravity (COG) were compared, and the concept of thresholds was introduced. Furthermore, a light convolutional neural network (CNN) was employed for testing. To enhance depth localization resolution, we proposed a method by utilizing the mutual information from both ends of the SiPMs. The source width and collimation effect were simulated using GEANT4, and the intrinsic spatial resolution was separated from the measured values.Main results.At an operational voltage of 29 V for the SiPM, an energy resolution of approximately 12.5 % was achieved. By subtracting a 0.8 % threshold from the total energy in every channel, a 2D spatial resolution of approximately 0.90 mm full width at half maximum (FWHM) can be obtained. Furthermore, a higher level of resolution, approximately 0.80 mm FWHM, was achieved using a CNN, with some alleviation of edge effects. With the proposed DOI method, a significant 1.36 mm FWHM average DOI resolution can be achieved. Additionally, it was found that polishing and black coating on the crystal surface yielded smaller edge effects compared to a rough surface with a black coating.Significance.The introduction of a threshold in COG method and a dual-ended readout scheme can lead to excellent spatial resolution for monolithic crystal detectors, which can help to develop PET systems with both high sensitivity and high spatial resolution.
Collapse
Affiliation(s)
- Xiangtao Zeng
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhiming Zhang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Daowu Li
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Xianchao Huang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Zhuoran Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Yingjie Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Wei Zhou
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Peilin Wang
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Meiling Zhu
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Qing Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Huixing Gong
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| | - Long Wei
- Beijing Engineering Research Centre of Radiographic Techniques and Equipment, Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
- Jinan Laboratory of Applied Nuclear Science, Jinan 250131, People's Republic of China
- CAEA Centre of Excellence on Nuclear Technology Applications for Nuclear Detection and Imaging, Beijing 100049, People's Republic of China
| |
Collapse
|
4
|
El Ouaridi A, Ait Elcadi Z, Mkimel M, Bougteb M, El Baydaoui R. The detection instrumentation and geometric design of clinical PET scanner: towards better performance and broader clinical applications. Biomed Phys Eng Express 2024; 10:032002. [PMID: 38412520 DOI: 10.1088/2057-1976/ad2d61] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Accepted: 02/27/2024] [Indexed: 02/29/2024]
Abstract
Positron emission tomography (PET) is a powerful medical imaging modality used in nuclear medicine to diagnose and monitor various clinical diseases in patients. It is more sensitive and produces a highly quantitative mapping of the three-dimensional biodistribution of positron-emitting radiotracers inside the human body. The underlying technology is constantly evolving, and recent advances in detection instrumentation and PET scanner design have significantly improved the medical diagnosis capabilities of this imaging modality, making it more efficient and opening the way to broader, innovative, and promising clinical applications. Some significant achievements related to detection instrumentation include introducing new scintillators and photodetectors as well as developing innovative detector designs and coupling configurations. Other advances in scanner design include moving towards a cylindrical geometry, 3D acquisition mode, and the trend towards a wider axial field of view and a shorter diameter. Further research on PET camera instrumentation and design will be required to advance this technology by improving its performance and extending its clinical applications while optimising radiation dose, image acquisition time, and manufacturing cost. This article comprehensively reviews the various parameters of detection instrumentation and PET system design. Firstly, an overview of the historical innovation of the PET system has been presented, focusing on instrumental technology. Secondly, we have characterised the main performance parameters of current clinical PET and detailed recent instrumental innovations and trends that affect these performances and clinical practice. Finally, prospects for this medical imaging modality are presented and discussed. This overview of the PET system's instrumental parameters enables us to draw solid conclusions on achieving the best possible performance for the different needs of different clinical applications.
Collapse
Affiliation(s)
- Abdallah El Ouaridi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Zakaria Ait Elcadi
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
- Electrical and Computer Engineering, Texas A&M University at Qatar, Doha, 23874, Qatar
| | - Mounir Mkimel
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Mustapha Bougteb
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| | - Redouane El Baydaoui
- Hassan First University of Settat, High Institute of Health Sciences, Laboratory of Health Sciences and Technologies, Settat, Morocco
| |
Collapse
|
5
|
Saaidi R, Rodríguez-Villafuerte M, Alva-Sánchez H, Martínez-Dávalos A. Crystal scatter effects in a large-area dual-panel Positron Emission Mammography system. PLoS One 2024; 19:e0297829. [PMID: 38427663 PMCID: PMC10906883 DOI: 10.1371/journal.pone.0297829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Accepted: 01/11/2024] [Indexed: 03/03/2024] Open
Abstract
Positron Emission Mammography (PEM) is a valuable molecular imaging technique for breast studies using pharmaceuticals labeled with positron emitters and dual-panel detectors. PEM scanners normally use large scintillation crystals coupled to sensitive photodetectors. Multiple interactions of the 511 keV annihilation photons in the crystals can result in event mispositioning leading to a negative impact in radiopharmaceutical uptake quantification. In this work, we report the study of crystal scatter effects of a large-area dual-panel PEM system designed with either monolithic or pixelated lutetium yttrium orthosilicate (LYSO) crystals using the Monte Carlo simulation platform GATE. The results show that only a relatively small fraction of coincidences (~20%) arise from events where both coincidence photons undergo single interactions (mostly through photoelectric absorption) in the crystals. Most of the coincidences are events where at least one of the annihilation photons undergoes a chain of Compton scatterings: approximately 79% end up in photoelectric absorption while the rest (<1%) escape the detector. Mean positioning errors, calculated as the distance between first hit and energy weighted (assigned) positions of interaction, were 1.70 mm and 1.92 mm for the monolithic and pixelated crystals, respectively. Reconstructed spatial resolution quantification with a miniDerenzo phantom and a list mode iterative reconstruction algorithm shows that, for both crystal types, 2 mm diameter hot rods were resolved, indicating a relatively small effect in spatial resolution. A drastic reduction in peak-to-valley ratios for the same hot-rod diameters was observed, up to a factor of 14 for the monolithic crystals and 7.5 for the pixelated ones.
Collapse
Affiliation(s)
- Rahal Saaidi
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| | | | - Héctor Alva-Sánchez
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| | - Arnulfo Martínez-Dávalos
- Instituto de Física, Universidad Nacional Autónoma de México, Ciudad Universitaria, Coyoacán, Mexico City, Mexico
| |
Collapse
|
6
|
Cates JW, Choong WS, Brubaker E. Scintillation and cherenkov photon counting detectors with analog silicon photomultipliers for TOF-PET. Phys Med Biol 2024; 69:045025. [PMID: 38252971 PMCID: PMC10861944 DOI: 10.1088/1361-6560/ad2125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 01/05/2024] [Accepted: 01/22/2024] [Indexed: 01/24/2024]
Abstract
Objective.Standard signal processing approaches for scintillation detectors in positron emission tomography (PET) derive accurate estimates for 511 keV photon time of interaction and energy imparted to the detection media from aggregate characteristics of electronic pulse shapes. The ultimate realization of a scintillation detector for PET is one that provides a unique timestamp and position for each detected scintillation photon. Detectors with these capabilities enable advanced concepts for three-dimensional (3D) position and time of interaction estimation with methods that exploit the spatiotemporal arrival time kinetics of individual scintillation photons.Approach.In this work, we show that taking into consideration the temporal photon emission density of a scintillator, the channel density of an analog silicon photomultiplier (SiPM) array, and employing fast electronic readout with digital signal processing, a detector that counts and timestamps scintillation photons can be realized. To demonstrate this approach, a prototype detector was constructed, comprising multichannel electronic readout for a bismuth germanate (BGO) scintillator coupled to an SiPM array.Main Results.In proof-of-concept measurements with this detector, we were able to count and provide unique timestamps for 66% of all optical photons, where the remaining 34% (two-or-more-photon pulses) are also independently counted, but each photon bunch shares a common timestamp. We show this detector concept can implement 3D positioning of 511 keV photon interactions and thereby enable corrections for time of interaction estimators. The detector achieved 17.6% energy resolution at 511 keV and 237 ± 10 ps full-width-at-half-maximum coincidence time resolution (CTR) (fast spectral component) versus a reference detector. We outline the methodology, readout, and approach for achieving this detector capability in first-ever, proof-of-concept measurements for scintillation photon counting detector with analog silicon photomultipliers.Significance.The presented detector concept is a promising design for large area, high sensitivity TOF-PET detector modules that can implement advanced event positioning and time of interaction estimators, which could push state-of-the-art performance.
Collapse
Affiliation(s)
- Joshua W Cates
- Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America
| | - Woon-Seng Choong
- Lawrence Berkeley National Laboratory, Berkeley, CA, United States of America
| | - Erik Brubaker
- Sandia National Laboratories, Livermore, CA, United States of America
| |
Collapse
|
7
|
Fang L, Zhang B, Li B, Zhang X, Zhou X, Yang J, Li A, Shi X, Liu Y, Kreissl M, D'Ascenzo N, Xiao P, Xie Q. Development and evaluation of a new high-TOF-resolution all-digital brain PET system. Phys Med Biol 2024; 69:025019. [PMID: 38100841 DOI: 10.1088/1361-6560/ad164d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2023] [Accepted: 12/15/2023] [Indexed: 12/17/2023]
Abstract
Objective.Time-of-flight (TOF) capability and high sensitivity are essential for brain-dedicated positron emission tomography (PET) imaging, as they improve the contrast and the signal-to-noise ratio (SNR) enabling a precise localization of functional mechanisms in the different brain regions.Approach.We present a new brain PET system with transverse and axial field-of-view (FOV) of 320 mm and 255 mm, respectively. The system head is an array of 6 × 6 detection elements, each consisting of a 3.9 × 3.9 × 20 mm3lutetium-yttrium oxyorthosilicate crystal coupled with a 3.93 × 3.93 mm2SiPM. The SiPMs analog signals are individually digitized using the multi-voltage threshold (MVT) technology, employing a 1:1:1 coupling configuration.Main results.The brain PET system exhibits a TOF resolution of 249 ps at 5.3 kBq ml-1, an average sensitivity of 22.1 cps kBq-1, and a noise equivalent count rate (NECR) peak of 150.9 kcps at 8.36 kBq ml-1. Furthermore, the mini-Derenzo phantom study demonstrated the system's ability to distinguish rods with a diameter of 2.0 mm. Moreover, incorporating the TOF reconstruction algorithm in an image quality phantom study optimizes the background variability, resulting in reductions ranging from 44% (37 mm) to 75% (10 mm) with comparable contrast. In the human brain imaging study, the SNR improved by a factor of 1.7 with the inclusion of TOF, increasing from 27.07 to 46.05. Time-dynamic human brain imaging was performed, showing the distinctive traits of cortex and thalamus uptake, as well as of the arterial and venous flow with 2 s per time frame.Significance.The system exhibited a good TOF capability, which is coupled with the high sensitivity and count rate performance based on the MVT digital sampling technique. The developed TOF-enabled brain PET system opens the possibility of precise kinetic brain PET imaging, towards new quantitative predictive brain diagnostics.
Collapse
Affiliation(s)
- Lei Fang
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Bo Zhang
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Bingxuan Li
- Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, Anhui, People's Republic of China
| | - Xiangsong Zhang
- Department of Nuclear Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, People's Republic of China
| | - Xiaoyun Zhou
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Jigang Yang
- Department of Nuclear Medicine, Beijing Friendship Hospital, Capital Medical University, Beijing, People's Republic of China
| | - Ang Li
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
| | - Xinchong Shi
- Department of Nuclear Medicine, The First Affiliated Hospital, Sun Yat-sen University, Guangzhou, Guangdong, People's Republic of China
| | - Yuqing Liu
- Institute of Artificial Intelligence, Hefei Comprehensive National Science Center, Hefei, Anhui, People's Republic of China
| | - Michael Kreissl
- Division of Nuclear Medicine, Deprtment of Radiology and Nuclear Medicine, University Hospital Magdeburg, Otto-von-Guericke University, Magdeburg, Germany
- Research Campus STIMULATE, Otto-von-Guericke University, Magdeburg, Germany
- German Center for Neurodegenerative Diseases (DZNE), Magdeburg, Germany
| | - Nicola D'Ascenzo
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, People's Republic of China
- Department of Innovation in Engineering and Physics, Istituto Neurologico Mediterraneo NEUROMED I.R.C.C.S., Pozzilli, Italy
| | - Peng Xiao
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, People's Republic of China
| | - Qingguo Xie
- Department of Biomedical Engineering, Huazhong University of Science and Technology, Wuhan, Hubei, People's Republic of China
- Department of Electronic Engineering and Information Science, University of Science and Technology of China, Hefei, Anhui, People's Republic of China
- Department of Innovation in Engineering and Physics, Istituto Neurologico Mediterraneo NEUROMED I.R.C.C.S., Pozzilli, Italy
| |
Collapse
|
8
|
Abstract
Biomedical research has long relied on small-animal studies to elucidate disease process and develop new medical treatments. The introduction of in vivo functional imaging technology, such as PET, has allowed investigators to peer inside their subjects and follow disease progression longitudinally as well as improve understanding of normal biological processes. Recent developments in CRISPR, immuno-PET, and high-resolution in vivo imaging have only increased the importance of small-animal, or preclinical, PET imaging. Other drivers of preclinical PET innovation include new combinations of imaging technologies, such as PET/MR imaging, which require changes to PET hardware.
Collapse
Affiliation(s)
- Adrienne L Lehnert
- Department of Radiology, University of Washington, 1959 Northeast Pacific Street, UW Box 356043, Seattle, WA, USA.
| | - Robert S Miyaoka
- Department of Radiology, University of Washington, 1959 Northeast Pacific Street, UW Box 356043, Seattle, WA, USA
| |
Collapse
|
9
|
Gonzalez-Montoro A, Levin CS. PET System Technology: Theoretical Aspects and Experimental Methodology. Methods Mol Biol 2024; 2729:343-369. [PMID: 38006506 DOI: 10.1007/978-1-0716-3499-8_20] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2023]
Abstract
Positron emission tomography (PET) imaging provides unique information of the cellular and molecular pathways of disease occurring within the human body, using measurements made from outside the body, which has shown utility in a variety of studies from basic research to clinical applications. This chapter describes some of the most relevant PET system parameters that impact its imaging performance such as 3D spatial, energy, and coincidence timing resolutions and the methodology typically used to evaluate those parameters. In addition, the physical principles underlying PET imaging, PET photon detector technology, and coincidence detection are also described. As a closing remark, the future perspectives of PET imaging and its simultaneous use with anatomical imaging techniques (e.g., computed tomography [CT] and magnetic resonance imaging [MRI]) are outlined.
Collapse
Affiliation(s)
| | - Craig S Levin
- Department of Radiology, Stanford University, Stanford, CA, USA.
- Departments of Radiology, Bioengineering, Physics, and Electrical Engineering, Stanford University, Stanford, CA, USA.
| |
Collapse
|
10
|
Lee JS, Lee MS. Advancements in Positron Emission Tomography Detectors: From Silicon Photomultiplier Technology to Artificial Intelligence Applications. PET Clin 2024; 19:1-24. [PMID: 37802675 DOI: 10.1016/j.cpet.2023.06.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/08/2023]
Abstract
This review article focuses on PET detector technology, which is the most crucial factor in determining PET image quality. The article highlights the desired properties of PET detectors, including high detection efficiency, spatial resolution, energy resolution, and timing resolution. Recent advancements in PET detectors to improve these properties are also discussed, including the use of silicon photomultiplier technology, advancements in depth-of-interaction and time-of-flight PET detectors, and the use of artificial intelligence for detector development. The article provides an overview of PET detector technology and its recent advancements, which can significantly enhance PET image quality.
Collapse
Affiliation(s)
- Jae Sung Lee
- Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 03080, South Korea; Brightonix Imaging Inc., Seoul 04782, South Korea
| | - Min Sun Lee
- Environmental Radioactivity Assessment Team, Nuclear Emergency & Environmental Protection Division, Korea Atomic Energy Research Institute, Daejeon 34057, South Korea.
| |
Collapse
|
11
|
Vandenberghe S, Muller FM, Withofs N, Dadgar M, Maebe J, Vervenne B, Akl MA, Xue S, Shi K, Sportelli G, Belcari N, Hustinx R, Vanhove C, Karp JS. Walk-through flat panel total-body PET: a patient-centered design for high throughput imaging at lower cost using DOI-capable high-resolution monolithic detectors. Eur J Nucl Med Mol Imaging 2023; 50:3558-3571. [PMID: 37466650 PMCID: PMC10547652 DOI: 10.1007/s00259-023-06341-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2023] [Accepted: 07/07/2023] [Indexed: 07/20/2023]
Abstract
PURPOSE Long axial field-of-view (LAFOV) systems have a much higher sensitivity than standard axial field-of-view (SAFOV) PET systems for imaging the torso or full body, which allows faster and/or lower dose imaging. Despite its very high sensitivity, current total-body PET (TB-PET) throughput is limited by patient handling (positioning on the bed) and often a shortage of available personnel. This factor, combined with high system costs, makes it hard to justify the implementation of these systems for many academic and nearly all routine nuclear medicine departments. We, therefore, propose a novel, cost-effective, dual flat panel TB-PET system for patients in upright standing positions to avoid the time-consuming positioning on a PET-CT table; the walk-through (WT) TB-PET. We describe a patient-centered, flat panel PET design that offers very efficient patient throughput and uses monolithic detectors (with BGO or LYSO) with depth-of-interaction (DOI) capabilities and high intrinsic spatial resolution. We compare system sensitivity, component costs, and patient throughput of the proposed WT-TB-PET to a SAFOV (= 26 cm) and a LAFOV (= 106 cm) LSO PET systems. METHODS Patient width, height (= top head to start of thighs) and depth (= distance from the bed to front of patient) were derived from 40 randomly selected PET-CT scans to define the design dimensions of the WT-TB-PET. We compare this new PET system to the commercially available Siemens Biograph Vision 600 (SAFOV) and Siemens Quadra (LAFOV) PET-CT in terms of component costs, system sensitivity, and patient throughput. System cost comparison was based on estimating the cost of the two main components in the PET system (Silicon Photomultipliers (SiPMs) and scintillators). Sensitivity values were determined using Gate Monte Carlo simulations. Patient throughput times (including CT and scout scan, patient positioning on bed and transfer) were recorded for 1 day on a Siemens Vision 600 PET. These timing values were then used to estimate the expected patient throughput (assuming an equal patient radiotracer injected activity to patients and considering differences in system sensitivity and time-of-flight information) for WT-TB-PET, SAFOV and LAFOV PET. RESULTS The WT-TB-PET is composed of two flat panels; each is 70 cm wide and 106 cm high, with a 50-cm gap between both panels. These design dimensions were justified by the patient sizes measured from the 40 random PET-CT scans. Each panel consists of 14 × 20 monolithic BGO detector blocks that are 50 × 50 × 16 mm in size and are coupled to a readout with 6 × 6 mm SiPMs arrays. For the WT-TB-PET, the detector surface is reduced by a factor of 1.9 and the scintillator volume by a factor of 2.2 compared to LAFOV PET systems, while demonstrating comparable sensitivity and much better uniform spatial resolution (< 2 mm in all directions over the FOV). The estimated component cost for the WT-TB-PET is 3.3 × lower than that of a 106 cm LAFOV system and only 20% higher than the PET component costs of a SAFOV. The estimated maximum number of patients scanned on a standard 8-h working day increases from 28 (for SAFOV) to 53-60 (for LAFOV in limited/full acceptance) to 87 (for the WT-TB-PET). By scanning faster (more patients), the amount of ordered activity per patient can be reduced drastically: the WT-TB-PET requires 66% less ordered activity per patient than a SAFOV. CONCLUSIONS We propose a monolithic BGO or LYSO-based WT-TB-PET system with DOI measurements that departs from the classical patient positioning on a table and allows patients to stand upright between two flat panels. The WT-TB-PET system provides a solution to achieve a much lower cost TB-PET approaching the cost of a SAFOV system. High patient throughput is increased by fast patient positioning between two vertical flat panel detectors of high sensitivity. High spatial resolution (< 2 mm) uniform over the FOV is obtained by using DOI-capable monolithic scintillators.
Collapse
Affiliation(s)
- Stefaan Vandenberghe
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium.
| | - Florence M Muller
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Nadia Withofs
- Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium
| | - Meysam Dadgar
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Jens Maebe
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Boris Vervenne
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Maya Abi Akl
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Song Xue
- Department of Nuclear Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Kuangyu Shi
- Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium
| | - Giancarlo Sportelli
- Dipartimento Di Fisica "E. Fermi", Università Di Pisa, Italy and with the Instituto Nazionale Di Fisica Nucleare, Sezione Di Pisa, 56127, Pisa, Italy
| | - Nicola Belcari
- Dipartimento Di Fisica "E. Fermi", Università Di Pisa, Italy and with the Instituto Nazionale Di Fisica Nucleare, Sezione Di Pisa, 56127, Pisa, Italy
| | - Roland Hustinx
- Division of Nuclear Medicine and Oncological Imaging, Department of Medical Physics, CHU of Liege, Quartier Hôpital, Avenue de Hôpital, 1, 4000, Liège 1, Belgium
| | - Christian Vanhove
- Medical Image and Signal Processing, Department of Electronics and Information Systems, Faculty of Engineering and Architecture, Ghent University, Corneel Heymanslaan 10, 9000, Ghent, Belgium
| | - Joel S Karp
- Physics and Instrumentation, Department of Radiology, University of Pennsylvania, Philadelphia, PA, USA
| |
Collapse
|
12
|
Li Y, Zeng X, Goldan AH. Decision Tree-Based Demultiplexing for Prism-PET. IEEE TRANSACTIONS ON NUCLEAR SCIENCE 2023; 70:1425-1430. [PMID: 38680514 PMCID: PMC11044823 DOI: 10.1109/tns.2023.3282831] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/01/2024]
Abstract
Signal multiplexing is necessary to reduce a large number of readout channels in positron emission tomography (PET) scanners to minimize cost and achieve lower power consumption. However, the conventional weighted average energy method cannot localize the multiplexed events and more sophisticated approaches are necessary for accurate demultiplexing. The purpose of this paper is to propose a non-parametric decision tree model for demultiplexing signals in prismatoid PET (Prism-PET) detector module that consisted of 16 × 16 lutetium yttrium oxyorthosilicate (LYSO) scintillation crystal array coupled to 8 × 8 silicon photomultiplier (SiPM) pixels with 64:16 multiplexed readout. A total of 64 regression trees were trained individually to demultiplex the encoded readouts for each SiPM pixel. The Center of Gravity (CoG) and Truncated Center of Gravity (TCoG) methods were utilized for crystal identification based on the demultiplexed pixels. The flood histogram, energy resolution, and depth-of-interaction (DOI) resolution were measured for comparison using with and without multiplexed readouts. In conclusion, our proposed decision tree model achieved accurate results for signal demultiplexing, and thus maintained the Prism-PET detector module's high spatial and DOI resolution performance while using our unique light-sharing-based multiplexed readout.
Collapse
Affiliation(s)
- Yixin Li
- Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, NY 11794, US
- Department of Radiology, Weill Cornell Medicine, Cornell University, NY 10021, US
| | - Xinjie Zeng
- Department of Electrical and Computer Engineering, College of Engineering and Applied Sciences, Stony Brook University, Stony Brook, NY 11794, US
- Department of Radiology, Weill Cornell Medicine, Cornell University, NY 10021, US
| | - Amir H Goldan
- Department of Radiology, Weill Cornell Medicine, Cornell University, NY 10021, US
| |
Collapse
|
13
|
Zatcepin A, Ziegler SI. Detectors in positron emission tomography. Z Med Phys 2023; 33:4-12. [PMID: 36208967 PMCID: PMC10082375 DOI: 10.1016/j.zemedi.2022.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Accepted: 08/25/2022] [Indexed: 11/05/2022]
Abstract
Positron emission tomography is a highly sensitive molecular imaging modality, based on the coincident detection of annihilation photons after positron decay. The most used detector is based on dense, fast, and luminous scintillators read out by light sensors. This review covers the various detector concepts for clinical and preclinical systems.
Collapse
Affiliation(s)
- Artem Zatcepin
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany; German Center for Neurodegenerative Diseases (DZNE), Munich, Germany
| | - Sibylle I Ziegler
- Department of Nuclear Medicine, University Hospital, LMU Munich, Munich, Germany.
| |
Collapse
|
14
|
Belov MV, Kozlov VA, Tskhay VS, Zavertyaev MV. Resolution estimation in different monolithic PET detectors using neural networks. Phys Med 2023; 106:102527. [PMID: 36610177 DOI: 10.1016/j.ejmp.2023.102527] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Revised: 12/29/2022] [Accepted: 01/02/2023] [Indexed: 01/07/2023] Open
Abstract
PURPOSE We use neural networks to evaluate and compare the spatial resolution of two different simulated monolithic PET detector elements. The effects of mixing events with single photoeffect interactions and multiple Compton scatterings are also studied. METHODS Two PET detector models were used in this study. The first one consisted of a LYSO crystal plate with 19.25 × 19.25 × 12 mm3 dimensions and 256-channel photomultiplier with parameters modeled after a Hamamatsu S-13615-1050N-16 SiPM. The second model used a larger LYSO crystal (57.6 × 57.6 × 12 mm3) and a 64-channel Sensl ARRAYC-60035-64P-PCB photomultiplier. A feed-forward neural network was used to reconstruct the point of 511 keV gamma interaction. The number of layers and the number of neurons per layer were varied. RESULTS The best resolution was achieved with the 57.6 × 57.6 mm2 detector model, with an average of 0.74 ± 0.01 mm for the XY plane and an average 1.01 ± 0.01 mm for the Z coordinate (depth of interaction). CONCLUSIONS Neural networks can be a powerful tool that can help to determine the optimal parameters for a design of an experimental device. This study demonstrates how neural networks can be used to evaluate the performance of two detector variants while not being dependent on specific signal and noise functions.
Collapse
Affiliation(s)
- M V Belov
- Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninskii Pr., 119991, Russia
| | - V A Kozlov
- Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninskii Pr., 119991, Russia
| | - V S Tskhay
- Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninskii Pr., 119991, Russia.
| | - M V Zavertyaev
- Lebedev Physical Institute, Russian Academy of Sciences, 53 Leninskii Pr., 119991, Russia
| |
Collapse
|
15
|
Maebe J, Vandenberghe S. Effect of detector geometry and surface finish on Cerenkov based time estimation in monolithic BGO detectors. Phys Med Biol 2023; 68. [PMID: 36595325 DOI: 10.1088/1361-6560/acabfd] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2022] [Accepted: 12/15/2022] [Indexed: 12/23/2022]
Abstract
Objective.Time-of-flight positron emission tomography based on bismuth germanate (BGO) detectors is made possible due to fast emission of Cerenkov light. Only around 17 Cerenkov photons are produced per 511 keV photoelectric event, making high photon collection efficiency crucial for obtaining good time-of-flight capabilities. In this study, we investigate how different lateral and back surface finishes affect the photon collection efficiency and Cerenkov based timing performance in monolithic BGO.Approach.The study is performed using GATE for gamma and optical photon modeling, with surface reflections of photons simulated by the LUT Davis model. We compare for different detector configurations (regarding size and surface finishes) the photon collection efficiency, detection delays of the first few optical photons and coincidence time resolution estimations obtained by modeling the SiPM signals and performing leading edge discrimination. An additional comparison is made to LYSO scintillators and pixelated detectors.Main results.Although Cerenkov photon emission is directional, many high incidence angle Cerenkov photons are emitted due to electron scattering in the crystal. Substituting a polished back (photodetector side) surface for a rough surface increases the collection efficiency of these high angle of incidence photons. Results show that for a monolithic 50 × 50 × 12 mm3BGO detector with reflective side surfaces, this leads to an overall increase in photon collection efficiency of 34%. Cerenkov photon collection efficiency is also improved, resulting in a reduction of the photon detection delays (and the variation therein) of the first few optical photons. This leads to a better coincidence time resolution, primarily achieved by a shortening of the tails in the time-of-flight kernel, with an 18% reduction in full width at tenth maximum.Significance.This study shows the importance of the photon collection efficiency for timing performance in Cerenkov based monolithic detectors, and how it can be improved with different surface finishes.
Collapse
Affiliation(s)
- Jens Maebe
- Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| | - Stefaan Vandenberghe
- Department of Electronics and Information Systems, Ghent University, Ghent, Belgium
| |
Collapse
|
16
|
Du J, Jones T. Technical opportunities and challenges in developing total-body PET scanners for mice and rats. EJNMMI Phys 2023; 10:2. [PMID: 36592266 PMCID: PMC9807733 DOI: 10.1186/s40658-022-00523-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 12/20/2022] [Indexed: 01/03/2023] Open
Abstract
Positron emission tomography (PET) is the most sensitive in vivo molecular imaging technique available. Small animal PET has been widely used in studying pharmaceutical biodistribution and disease progression over time by imaging a wide range of biological processes. However, it remains true that almost all small animal PET studies using mouse or rat as preclinical models are either limited by the spatial resolution or the sensitivity (especially for dynamic studies), or both, reducing the quantitative accuracy and quantitative precision of the results. Total-body small animal PET scanners, which have axial lengths longer than the nose-to-anus length of the mouse/rat and can provide high sensitivity across the entire body of mouse/rat, can realize new opportunities for small animal PET. This article aims to discuss the technical opportunities and challenges in developing total-body small animal PET scanners for mice and rats.
Collapse
Affiliation(s)
- Junwei Du
- grid.27860.3b0000 0004 1936 9684Department of Biomedical Engineering, University of California at Davis, Davis, CA 95616 USA
| | - Terry Jones
- grid.27860.3b0000 0004 1936 9684Department of Radiology, University of California at Davis, Davis, CA 95616 USA
| |
Collapse
|
17
|
Hunter W, Dolinsky S, Kinahan P, Miyaoka R. Timing, Energy, and 3-D Spatial Resolution of the BING PET Detector Module. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2023; 7:1-10. [PMID: 36644761 PMCID: PMC9835997 DOI: 10.1109/trpms.2022.3187955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
We evaluated the 3D spatial, energy, and timing resolution of the Brain (or Breast)-Initiative Next-Generation (BING) PET detector. The BING detector is an array of 1-mm-thick slats of LYSO scintillator with lapped specular-reflective faces (15-mm by 52-mm) that are stacked together and oriented with their long-narrow edges normal to the imaging field of view. Interaction positions are determined from the signals of silicon-photomultiplier (SiPM) arrays placed on the entrance (top) and exit (bottom) faces. The SiPM arrays are offset to determine the slat of interaction (SOI) without requiring any optical light sharing between slats. Maximum likelihood 2D location within the SOI is determined using the sensor signals. Interaction time is determined with a modified first-optical-photon pickoff method. Performance of the BING detector was measured as a function of position using a sideways coincidence-collimated beam. Slats were accurately identified, with an effective tangential detector resolution of 1 mm. Average resolutions (and ranges) are: 0.96 mm (0.85 mm to 1.11 mm) for lateral (axial) detector resolution, 1.6 mm (1.0 mm to 2.1 mm) for depth resolution, 13.6% (12.7% to 16.0%) for energy resolution, and 317 ps (241 ps to 404 ps) for coincidence timing resolution. Initial spatial and timing resolution results demonstrated that the BING detector can be effective in a small field-of view (e.g., brain or breast) PET system.
Collapse
Affiliation(s)
- William Hunter
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| | - Sergei Dolinsky
- Sergei Dolinsky is with GE Research, Semiconductors, Niskayuna, NY, 12309, USA
| | - Paul Kinahan
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| | - Robert Miyaoka
- William Hunter, Paul Kinahan, and Robert Miyaoka are with Dept of Rad., U. of Wa, Seattle, WA 98195 USA
| |
Collapse
|
18
|
Freire M, Barrio J, Cucarella N, Valladares C, Gonzalez-Montoro A, de Alfonso C, Benlloch JM, Gonzalez AJ. Position estimation using neural networks in semi-monolithic PET detectors. Phys Med Biol 2022; 67. [PMID: 36384047 DOI: 10.1088/1361-6560/aca389] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 11/16/2022] [Indexed: 11/18/2022]
Abstract
Objective. The goal of this work is to experimentally compare the 3D spatial and energy resolution of a semi-monolithic detector suitable for total-body positron emission tomography (TB-PET) scanners using different surface crystal treatments and silicon photomultiplier (SiPM) models.Approach. An array of 1 × 8 lutetium yttrium oxyorthosilicate (LYSO) slabs of 25.8 × 3.1 × 20 mm3separated with Enhanced Specular Reflector (ESR) was coupled to an array of 8 × 8 SiPMs. Three different treatments for the crystal were evaluated: ESR + RR + B,with lateral faces black (B) painted and a retroreflector (RR) layer added to the top face; ESR +RR, with lateral faces covered with ESR and a RR layer on the top face and; All ESR, with lateral and top sides with ESR. Additionally, two SiPM array models from Hamamatsu Photonics belonging to the series S13361-3050AE-08 (S13) and S14161-3050AS-08 (S14) have been compared. Coincidence data was experimentally acquired using a22Na point source, a pinhole collimator, a reference detector and moving the detector under study in 1 mm steps in thex- andDOI- directions. The spatial performance was evaluated by implementing a neural network (NN) technique for the impact position estimation in thex- (monolithic) andDOIdirections.Results. Energy resolution values of 16 ± 1%, 11 ± 1%, 16 ± 1%, 15 ± 1%, and 13 ± 1% were obtained for theS13-ESR + B + RR,S13-AllESR,S14-ESR + B + RR,S14-ESR + RR,andS14-AllESR, respectively. Regarding positioning accuracy, mean average error of 1.1 ± 0.5, 1.3 ± 0.5 and 1.3 ± 0.5 were estimated for thex- direction and 1.7 ± 0.8, 2.0 ± 0.9 and 2.2 ± 1.0 for theDOI- direction, for the ESR + B + RR, ESR + RR and All ESR cases, respectively, regardless of the SiPM model.Significance. Overall, the obtained results show that the proposed semi-monolithic detectors are good candidates for building TB-PET scanners.
Collapse
Affiliation(s)
- M Freire
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - J Barrio
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - N Cucarella
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - C Valladares
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - A Gonzalez-Montoro
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - C de Alfonso
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - J M Benlloch
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| | - A J Gonzalez
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Camino de Vera s/n, E-46022 Valencia, Spain
| |
Collapse
|
19
|
A new brain dedicated PET scanner with 4D detector information. BIO-ALGORITHMS AND MED-SYSTEMS 2022. [DOI: 10.2478/bioal-2022-0083] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Abstract
In this article, we present the geometrical design and preliminary results of a high sensitivity organ-specific Positron Emission Tomography (PET) system dedicated to the study of the human brain. The system, called 4D-PET, will allow accurate imaging of brain studies due to its expected high sensitivity, high 3D spatial resolution and, by including precise photon time of flight (TOF) information, a boosted signal-to-noise ratio (SNR).
The 4D-PET system incorporates an innovative detector design based on crystal slabs (semi-monolithic) that enables accurate 3D photon impact positioning (including photon Depth of Interaction (DOI) measurement), while providing a precise determination of the photon arrival time to the detector. The detector includes a novel readout system that reduces the number of detector signals in a ratio of 4:1 thus, alleviating complexity and cost. The analog output signals are fed to the TOFPET2 ASIC (PETsys) for scalability purposes.
The present manuscript reports the evaluation of the 4D-PET detector, achieving best values 3D resolution values of <1.6 mm (pixelated axis), 2.7±0.5 mm (monolithic axis) and 3.4±1.1 (DOI axis) mm; 359 ± 7 ps coincidence time resolution (CTR); 10.2±1.5 % energy resolution; and sensitivity of 16.2% at the center of the scanner (simulated). Moreover, a comprehensive description of the 4D-PET architecture (that includes 320 detectors), some pictures of its mechanical assembly, and simulations on the expected image quality are provided.
Collapse
|
20
|
Mueller F, Naunheim S, Kuhl Y, Schug D, Solf T, Schulz V. A semi-monolithic detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-capabilities for clinical PET applications. Med Phys 2022; 49:7469-7488. [PMID: 36259245 DOI: 10.1002/mp.16015] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2022] [Revised: 06/25/2022] [Accepted: 09/11/2022] [Indexed: 12/27/2022] Open
Abstract
BACKGROUND Current clinical positron emission tomography (PET) systems utilize detectors where the scintillator typically contains single elements of 3-6-mm width and about 20-mm height. While providing good time-of-flight performance, this design limits the spatial resolution and causes radial astigmatism as the depth-of-interaction (DOI) remains unknown. PURPOSE We propose an alternative, aiming to combine the advantages of current detectors with the DOI capabilities shown for monolithic concepts, based on semi-monolithic scintillators (slabs). Here, the optical photons spread along one dimension enabling DOI-encoding with a still small readout area beneficial for timing performance. METHODS An array of eight monolithic LYSO slabs of dimensions 3.9 × 32 × 19 mm3 was read out by a 64-channel photosensor containing digital SiPMs (DPC3200-22-44, Philips Digital Photon Counting). The position estimation in the detector's monolithic and DOI direction was based on a calibration with a fan beam collimator and the machine learning technique gradient tree boosting (GTB). RESULTS We achieved a positioning performance in terms of mean absolute error (MAE) of 1.44 mm for the monolithic direction and 2.12 mm for DOI considering a wide energy window of 300-700 keV. The energy resolution was determined to be 11.3%, applying a positional-dependent energy calibration. We established both an analytical and machine-learning-based timing calibration approach and applied them for a first-photon trigger. The analytical timing calibration corrects for electronic and optical time skews leading to 240 ps coincidence resolving time (CRT) for a pair of slab-detectors. The CRT was significantly improved by utilizing GTB to predict the time difference based on specific training data and applied on top of the analytical calibration. We achieved 209 ps for the wide energy window and 198 ps for a narrow selection around the photopeak (411-561 keV). To maintain the detector's sensitivity, no filters were applied to the data during processing. CONCLUSION Overall, the semi-monolithic detector provides attractive performance characteristics. Especially, a good CRT can be achieved while introducing DOI capabilities to the detector, making the concept suitable for clinical PET scanners.
Collapse
Affiliation(s)
- Florian Mueller
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Stephan Naunheim
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - Yannick Kuhl
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany
| | - David Schug
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.,Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany
| | - Torsten Solf
- Philips Digital Photon Counting (PDPC), Aachen, Germany
| | - Volkmar Schulz
- Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen, Germany.,Hyperion Hybrid Imaging Systems GmbH, Aachen, Germany.,Fraunhofer Institute for Digital Medicine MEVIS, Aachen, Germany.,III. Institute of Physics B, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
21
|
Gonzalez-Montoro A, Ullah MN, Levin CS. Advances in Detector Instrumentation for PET. J Nucl Med 2022; 63:1138-1144. [PMID: 35914819 PMCID: PMC9364348 DOI: 10.2967/jnumed.121.262509] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 04/22/2022] [Indexed: 02/03/2023] Open
Abstract
During the last 3 decades, PET has become a standard-of-care imaging technique used in the management of cancer and in the characterization of neurologic disorders and cardiovascular disease. It has also emerged as a prominent molecular imaging method to study the basic biologic pathways of disease in rodent models. This review describes the basics of PET detectors, including a detailed description of indirect and direct 511-keV photon detection methods. We will also cover key detector performance parameters and describe detector instrumentation advances during the last decade.
Collapse
Affiliation(s)
- Andrea Gonzalez-Montoro
- Department of Radiology, Molecular Imaging Program at Stanford University, Stanford, California
| | - Muhammad Nasir Ullah
- Department of Radiology, Molecular Imaging Program at Stanford University, Stanford, California
| | - Craig S. Levin
- Department of Radiology, Molecular Imaging Program at Stanford University, Stanford, California;,Department of Physics, Stanford University, Stanford, California;,Department of Electrical Engineering, Stanford University, Stanford, California; and,Department of Bioengineering, Stanford University, Stanford, California
| |
Collapse
|
22
|
Carra P, Giuseppina Bisogni M, Ciarrocchi E, Morrocchi M, Sportelli G, Rosso V, Belcari N. A neural network-based algorithm for simultaneous event positioning and timestamping in monolithic scintillators. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac72f2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/09/2021] [Accepted: 05/24/2022] [Indexed: 11/11/2022]
Abstract
Abstract
Objective. Monolithic scintillator crystals coupled to silicon photomultiplier (SiPM) arrays are promising detectors for PET applications, offering spatial resolution around 1 mm and depth-of-interaction information. However, their timing resolution has always been inferior to that of pixellated crystals, while the best results on spatial resolution have been obtained with algorithms that cannot operate in real-time in a PET detector. In this study, we explore the capabilities of monolithic crystals with respect to spatial and timing resolution, presenting new algorithms that overcome the mentioned problems. Approach. Our algorithms were tested first using a simulation framework, then on experimentally acquired data. We tested an event timestamping algorithm based on neural networks which was then integrated into a second neural network for simultaneous estimation of the event position and timestamp. Both algorithms are implemented in a low-cost field-programmable gate array that can be integrated in the detector and can process more than 1 million events per second in real-time. Results. Testing the neural network for the simultaneous estimation of the event position and timestamp on experimental data we obtain 0.78 2D FWHM on the (x, y) plane, 1.2 depth-of-interaction FWHM and 156 coincidence time resolution on a
25
mm
×
25
mm
×
8
mm
×
LYSO monolith read-out by 64
3
mm
×
3
mm
Hamamatsu SiPMs. Significance. Our results show that monolithic crystals combined with artificial intelligence can rival pixellated crystals performance for time-of-flight PET applications, while having better spatial resolution and DOI resolution. Thanks to the use of very light neural networks, event characterization can be done on-line directly in the detector, solving the issues of scalability and computational complexity that up to now were preventing the use of monolithic crystals in clinical PET scanners.
Collapse
|
23
|
Freire M, Gonzalez-Montoro A, Cañizares G, Rezaei A, Nuyts J, Berr SS, Williams MB, Benlloch JM, Gonzalez AJ. Experimental validation of a rodent PET scanner prototype based on a single LYSO crystal tube. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2022; 6:697-706. [PMID: 35909498 PMCID: PMC9328404 DOI: 10.1109/trpms.2021.3124448] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
Improving sensitivity and spatial resolution in small animal Positron Emission Tomography imaging instrumentation constitutes one of the main goals of nuclear imaging research. These parameters are degraded by the presence of gaps between the detectors. The present manuscript experimentally validates our prototype of an edge-less pre-clinical PET system based on a single LYSO:Ce annulus with an inner diameter of 62 mm and 10 outer facets of 26 × 52 mm2. Scintillation light is read out by arrays of 8 × 8 SiPMs coupled to the facets, using a projection readout of the rows and columns signals. The readout provides accurate Depth of Interaction (DOI). We have implemented a calibration that mitigates the DOI-dependency of the transaxial and axial impact coordinates, and the energy photopeak gain. An energy resolution of 23.4 ± 1.8% was determined. Average spatial resolution of 1.4 ± 0.2 and 1.3 ± 0.4 mm FWHM were achieved for the radial and axial directions, respectively. We found a peak sensitivity of 3.8% at the system center, and a maximum NECR at 40.6 kcps for 0.27 mCi. The image quality was evaluated using reconstructed images of an array of sources and the NEMA image quality phantom was also studied.
Collapse
Affiliation(s)
- Marta Freire
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | | | - Gabriel Cañizares
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | - Ahmadreza Rezaei
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Leuven, Belgium
| | - Johan Nuyts
- Department of Imaging and Pathology, Nuclear Medicine & Molecular imaging, KU Leuven, Leuven, Belgium
| | - Stuart S Berr
- Department of Radiology and Medical Imaging, The University of Virginia, Charlottesville, Virginia, United States
| | - Mark B Williams
- Department of Radiology and Medical Imaging, The University of Virginia, Charlottesville, Virginia, United States
| | - Jose M Benlloch
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| | - Antonio J Gonzalez
- Instituto de Instrumentación para la Imagen Molecular (i3M-CSIC-UPV), Valencia, Spain
| |
Collapse
|
24
|
Maebe J, Vandenberghe S. Simulation study on 3D convolutional neural networks for time-of-flight prediction in monolithic PET detectors using digitized waveforms. Phys Med Biol 2022; 67. [DOI: 10.1088/1361-6560/ac73d3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 05/26/2022] [Indexed: 11/12/2022]
Abstract
Abstract
Objective. We investigate the use of 3D convolutional neural networks for gamma arrival time estimation in monolithic scintillation detectors. Approach. The required data is obtained by Monte Carlo simulation in GATE v8.2, based on a 50 × 50 × 16 mm3 monolithic LYSO crystal coupled to an 8 × 8 readout array of silicon photomultipliers (SiPMs). The electronic signals are simulated as a sum of bi-exponentional functions centered around the scintillation photon detection times. We include various effects of statistical fluctuations present in non-ideal SiPMs, such as dark counts and limited photon detection efficiency. The data was simulated for two distinct overvoltages of the SensL J-Series 60 035 SiPMs, in order to test the effects of different SiPM parameters. The neural network uses the array of detector waveforms, digitized at 10 GS s−1, to predict the time at which the gamma arrived at the crystal. Main results. Best results were achieved for an overvoltage of +6 V, at which point the SiPM reaches its optimal photon detection efficiency, resulting in a coincidence time resolution (CTR) of 141 ps full width at half maximum (FWHM). It is a 26% improvement compared to a simple averaging of the first few SiPM timestamps obtained by leading edge discrimination, which in comparison produced a CTR of 177 ps FWHM. In addition, better detector uniformity was achieved, although some degradation near the corners did remain. Significance. These improvements in time resolution can lead to higher signal-to-noise ratios in time-of-flight positron emission tomography, ultimately resulting in better diagnostic capabilities.
Collapse
|
25
|
Freire M, Echegoyen S, Gonzalez-Montoro A, Sanchez F, Gonzalez AJ. Performance evaluation of side-by-side optically coupled monolithic LYSO crystals. Med Phys 2022; 49:5616-5626. [PMID: 35689501 PMCID: PMC9545681 DOI: 10.1002/mp.15792] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 05/12/2022] [Accepted: 05/25/2022] [Indexed: 11/12/2022] Open
Abstract
Background Significant interest has been recently shown for using monolithic scintillation crystals in molecular imaging systems, such as positron emission tomography (PET) scanners. Monolithic‐based PET scanners result in a lower cost and higher sensitivity, in contrast to systems based on the more conventional pixellated configuration. The monolithic design allows one to retrieve depth‐of‐interaction information of the impinging 511 keV photons without the need for additional hardware materials or complex positioning algorithms. However, the so‐called edge‐effect inherent to monolithic‐based approaches worsens the detector performance toward the crystal borders due to the truncation of the light distribution, thus decreasing positioning accuracy. Purpose The main goal of this work is to experimentally demonstrate the detector performance improvement when machine‐learning artificial neural‐network (NN) techniques are applied for positioning estimation in multiple monolithic scintillators optically coupled side‐by‐side. Methods In this work, we show the performance evaluation of two LYSO crystals of 33 × 25.4 × 10 mm3 optically coupled by means of a high refractive index adhesive compound (Meltmount, refractive index n = 1.70). A 12 × 12 silicon photomultiplier array has been used as photosensor. For comparison, the same detector configuration was tested for two additional coupling cases: (1) optical grease (n = 1.46) in between crystals, and (2) isolated crystals using black paint with an air gap at the interface (named standard configuration). Regarding 2D photon positioning (XY plane), we have tested two different methods: (1) a machine‐learning artificial NN algorithm and (2) a squared‐charge (SC) centroid technique. Results At the interface region of the detector, the SC method achieved spatial resolutions of 1.7 ± 0.3, 2.4 ± 0.3, and 2.6 ± 0.4 mm full‐width at half‐maximum (FWHM) for the Meltmount, grease, and standard configurations, respectively. These values improve to 1.0 ± 0.2, 1.2 ± 0.2, and 1.2 ± 0.3 mm FWHM when the NN algorithm was employed. Regarding energy performance, resolutions of 18 ± 2%, 20 ± 2%, and 23 ± 3% were obtained at the interface region of the detector for Meltmount, grease, and standard configurations, respectively. Conclusions The results suggest that optically coupling together scintillators with a high refractive index adhesive, in combination with an NN algorithm, reduces edge‐effects and makes it possible to build scanners with almost no gaps in between detectors.
Collapse
Affiliation(s)
- Marta Freire
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain
| | - Sara Echegoyen
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain
| | - Andrea Gonzalez-Montoro
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain
| | - Filomeno Sanchez
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain
| | - Antonio J Gonzalez
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro Mixto CSIC - Universitat Politècnica de València, Valencia, Spain
| |
Collapse
|
26
|
Gonzalez‐Montoro A, Vera‐Donoso CD, Konstantinou G, Sopena P, Martinez M, Ortiz JB, Carles M, Benlloch J, Gonzalez A. Nuclear‐medicine probes: where we are and where we are going. Med Phys 2022; 49:4372-4390. [PMID: 35526220 PMCID: PMC9545507 DOI: 10.1002/mp.15690] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 04/08/2022] [Accepted: 04/26/2022] [Indexed: 11/10/2022] Open
Abstract
Nuclear medicine probes turned into the key for the identification and precise location of sentinel lymph nodes and other occult lesions (i.e., tumors) by using the systemic administration of radiotracers. Intraoperative nuclear probes are key in the surgical management of some malignancies as well as in the determination of positive surgical margins, thus reducing the extent and potential surgery morbidity. Depending on their application, nuclear probes are classified into two main categories, namely, counting and imaging. Although counting probes present a simple design, are handheld (to be moved rapidly), and provide only acoustic signals when detecting radiation, imaging probes, also known as cameras, are more hardware‐complex and also able to provide images but at the cost of an increased intervention time as displacing the camera has to be done slowly. This review article begins with an introductory section to highlight the relevance of nuclear‐based probes and their components as well as the main differences between ionization‐ (semiconductor) and scintillation‐based probes. Then, the most significant performance parameters of the probe are reviewed (i.e., sensitivity, contrast, count rate capabilities, shielding, energy, and spatial resolution), as well as the different types of probes based on the target radiation nature, namely: gamma (γ), beta (β) (positron and electron), and Cherenkov. Various available intraoperative nuclear probes are finally compared in terms of performance to discuss the state‐of‐the‐art of nuclear medicine probes. The manuscript concludes by discussing the ideal probe design and the aspects to be considered when selecting nuclear‐medicine probes.
Collapse
Affiliation(s)
- A. Gonzalez‐Montoro
- Instituto de Instrumentación para Imagen Molecular (I3M) Centro Mixto CSIC Universitat Politècnica de València Camino de Vera s/n Valencia 46022 Spain
| | | | | | - P. Sopena
- Servicio de Medicina Nuclear Área clínica de Imagen Médica, La Fe Hospital Valencia 46026 Spain
| | - M. Martinez
- Urology Department La Fe Hospital Valencia 46026 Spain
| | - J. B. Ortiz
- Urology Department La Fe Hospital Valencia 46026 Spain
| | - M. Carles
- Biomedical Imaging Research Group La Fe Hospital Valencia 46026 Spain
| | - J.M. Benlloch
- Instituto de Instrumentación para Imagen Molecular (I3M) Centro Mixto CSIC Universitat Politècnica de València Camino de Vera s/n Valencia 46022 Spain
| | - A.J. Gonzalez
- Instituto de Instrumentación para Imagen Molecular (I3M) Centro Mixto CSIC Universitat Politècnica de València Camino de Vera s/n Valencia 46022 Spain
| |
Collapse
|
27
|
Cates JW, Steele J, Balajthy J, Negut V, Hausladen P, Ziock K, Brubaker E. Front-End Design for SiPM-Based Monolithic Neutron Double Scatter Imagers. SENSORS 2022; 22:s22093553. [PMID: 35591242 PMCID: PMC9101142 DOI: 10.3390/s22093553] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 04/25/2022] [Accepted: 04/26/2022] [Indexed: 02/04/2023]
Abstract
Neutron double scatter imaging exploits the kinematics of neutron elastic scattering to enable emission imaging of neutron sources. Due to the relatively low coincidence detection efficiency of fast neutrons in organic scintillator arrays, imaging efficiency for double scatter cameras can also be low. One method to realize significant gains in neutron coincidence detection efficiency is to develop neutron double scatter detectors which employ monolithic blocks of organic scintillator, instrumented with photosensor arrays on multiple faces to enable 3D position and multi-interaction time pickoff. Silicon photomultipliers (SiPMs) have several advantageous characteristics for this approach, including high photon detection efficiency (PDE), good single photon time resolution (SPTR), high gain that translates to single photon counting capabilities, and ability to be tiled into large arrays with high packing fraction and photosensitive area fill factor. However, they also have a tradeoff in high uncorrelated and correlated noise rates (dark counts from thermionic emissions and optical photon crosstalk generated during avalanche) which may complicate event positioning algorithms. We have evaluated the noise characteristics and SPTR of Hamamatsu S13360-6075 SiPMs with low noise, fast electronic readout for integration into a monolithic neutron scatter camera prototype. The sensors and electronic readout were implemented in a small-scale prototype detector in order to estimate expected noise performance for a monolithic neutron scatter camera and perform proof-of-concept measurements for scintillation photon counting and three-dimensional event positioning.
Collapse
Affiliation(s)
- Joshua W. Cates
- Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA;
- Correspondence:
| | - John Steele
- Sandia National Laboratories, Livermore, CA 94550, USA; (J.S.); (J.B.); (E.B.)
| | - Jon Balajthy
- Sandia National Laboratories, Livermore, CA 94550, USA; (J.S.); (J.B.); (E.B.)
| | - Victor Negut
- Lawrence Berkeley National Laboratory, Berkeley, CA 94720, USA;
| | - Paul Hausladen
- Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA; (P.H.); (K.Z.)
| | - Klaus Ziock
- Oak Ridge National Laboratory, Oak Ridge, TN 37831, USA; (P.H.); (K.Z.)
| | - Erik Brubaker
- Sandia National Laboratories, Livermore, CA 94550, USA; (J.S.); (J.B.); (E.B.)
| |
Collapse
|
28
|
Thyssen C, Deprez K, Mollet P, Van Holen R, Vandenberghe S. Simulation study on the performance of time-over-threshold based positioning in monolithic PET detectors. Phys Med Biol 2021; 66. [PMID: 34875646 DOI: 10.1088/1361-6560/ac40d1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Accepted: 12/07/2021] [Indexed: 11/12/2022]
Abstract
The vast majority of PET detectors in the field today are based on pixelated scintillators. Yet, the resolution of this type of detector is limited by the pixel size. To overcome this limitation, one can use monolithic detectors. However, this detector architecture demands specific and high-speed detector readout of the photodetector array. A commonly used approach is to integrate the current pulses generated by every pixel but such circuitry quickly becomes bulky, power consuming and expensive. The objective of this work is to investigate a novel readout and event positioning scheme for monolithic PET detectors, based on time-over-threshold (ToT). In this case, we measure the time that the pulse is above a certain threshold through a comparator. The pulse widths are used for event positioning using a mean nearest neighbour approach (mNNToT). For energy determination one integrating multiplexed channel is foreseen. We evaluate the positioning accuracy and uniformity of such a ToT detector by means of Monte Carlo simulations. The impact of the threshold value is investigated and the results are compared to a detector using mean nearest neighbour with pulse-integration (mNNint), which has already proven to allow sub-mm resolution. We show minimal degradation in spatial resolution and bias performance compared to mNNint. The highest threshold results in the worst resolution performance but degradation remains below 0.1 mm. Bias is largely constant over different thresholds for mNNToTand close to identical to mNNint. Furthermore we show that ToT performs well in terms of detector uniformity and that scattered photons can be positioned inside the crystal with high accuracy. We conclude from this work that ToT is a valuable alternative to pulse-integration for monolithic PET detectors. This novel approach has an impact on PET detector development since it has the advantage of lower power consumption, compactness and inherent amplitude-to-time conversion.
Collapse
Affiliation(s)
- Charlotte Thyssen
- Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium.,MOLECUBES, Ghent, Belgium
| | | | | | - Roel Van Holen
- Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium.,MOLECUBES, Ghent, Belgium
| | | |
Collapse
|
29
|
Freire M, Cañizares G, Echegoyen S, Gonzalez-Montoro A, Gonzalez AJ. Reducing Calibration Time in PET Systems Based on Monolithic Crystals. Front Med (Lausanne) 2021; 8:734476. [PMID: 34859004 PMCID: PMC8631296 DOI: 10.3389/fmed.2021.734476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 10/11/2021] [Indexed: 11/13/2022] Open
Abstract
In the past years, the gamma-ray detector designs based on the monolithic crystals have demonstrated to be excellent candidates for the design of high-performance PET systems. The monolithic crystals allow to achieve the intrinsic detector resolutions well below state-of-the-art; to increase packing fraction thus, increasing the system sensitivity; and to improve lesion detectability at the edges of the scanner field of view (FOV) because of their intrinsic depth of interaction (DOI) capabilities. The bottleneck to translate to the clinical PET systems based on a large number of monolithic detectors is eventually the requirement of mechanically complex and time-consuming calibration processes. To mitigate this drawback, several methods have been already proposed, such as using non-physically collimated radioactive sources or implementing the neuronal networks (NN) algorithms trained with simulated data. In this work, we aimed to simplify and fasten a calibration process of the monolithic based systems. The Normal procedure consists of individually acquiring a 11 × 11 22Na source array for all the detectors composing the PET system and obtaining the calibration map for each module using a method based on the Voronoi diagrams. Two reducing time methodologies are presented: (i) TEST1, where the calibration map of one detector is estimated and shared among all others, and (ii) TEST2, where the calibration map is slightly modified for each module as a function of their detector uniformity map. The experimental data from a dedicated prostate PET system was used to compare the standard calibration procedure with both the proposed methods. A greater similarity was exhibited between the TEST2 methodology and the Normal procedure; obtaining spatial resolution variances within 0.1 mm error bars and count rate deviations as small as 0.2%. Moreover, the negligible reconstructed image differences (13% deviation at most in the contrast-to-noise ratio) and almost identical contrast values were reported. Therefore, this proposed method allows us to calibrate the PET systems based on the monolithic crystals reducing the calibration time by approximately 80% compared with the Normal procedure.
Collapse
Affiliation(s)
- Marta Freire
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Gabriel Cañizares
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Sara Echegoyen
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Andrea Gonzalez-Montoro
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
| | - Antonio J Gonzalez
- Instituto de Instrumentación para Imagen Molecular, Centro Mixto CSIC-Universitat Politècnica de València, Valencia, Spain
| |
Collapse
|
30
|
Cucarella N, Barrio J, Lamprou E, Valladares C, Benlloch JM, Gonzalez AJ. Timing evaluation of a PET detector block based on semi-monolithic LYSO crystals. Med Phys 2021; 48:8010-8023. [PMID: 34723380 DOI: 10.1002/mp.15318] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2021] [Revised: 09/25/2021] [Accepted: 10/15/2021] [Indexed: 11/10/2022] Open
Abstract
PURPOSE Detectors for positron emission tomography (PET) typically use two types of scintillation crystals, pixelated or monolithic. A variant of these types of scintillators are the so-called semi-monolithic crystals. They consist of a monolithic crystal segmented in one direction in pieces called slabs. These scintillators have the potential to successfully combine the benefits of pixelated and monolithic configurations, providing good timing and spatial resolutions as well as the capacity to decode the depth of interaction (DOI) information. In this work, the timing performance of a detector based on semi-monolithic crystals was studied in depth. The energy response was also evaluated. METHODS The semi-monolithic detector consists of 1 × 24 LYSO slabs of 25.4 × 12 × 0.95 mm3 each. The bottom surface of the slabs is coupled to an array of 8 × 8 silicon photomultipliers (SiPMs) of 3 × 3 mm2 active area, 50 μm cell size and 3.2 mm pitch. The 64 output signals were independently readout by the TOFPET2 ASIC. In order to achieve the best coincidence time resolution (CTR), four different time walk corrections were tested. Additional work investigated the best method of combining the timestamps belonging to the same event. RESULTS The resolvability of the slabs in the measured flood maps improves with the thickness of a light guide placed in between the scintillators and photosensors. The energy resolution does not change significantly with values as good as 13.7%. Regarding the CTR, values of 335.8, 363, 369.8, and 402.5 ps have been obtained for the whole detector for no light guide, 0.5, 1.0, and 1.5 mm thickness light guide cases, respectively. These values further improve to 276.1, 302.6, 305.6 and 336.2 ps, respectively, when energy-weighted averaging of timestamps is applied. CONCLUSIONS We have shown both an excellent timing resolution and good energy resolution for a PET detector based on semi-monolithic crystals. The use of light guides of different thicknesses does not significantly affect the energy resolution of the whole detector, but the timing capabilities slightly worsen with the increasing thickness of the light guide.
Collapse
Affiliation(s)
- Neus Cucarella
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| | - John Barrio
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| | - Efthymios Lamprou
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| | - Celia Valladares
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| | - Jose M Benlloch
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| | - Antonio J Gonzalez
- Instituto de Instrumentación para Imagen Molecular (I3M), Centro mixto CSIC-Universitat Politècnica de València, Valencia, 46022, Spain
| |
Collapse
|
31
|
Schaart DR, Schramm G, Nuyts J, Surti S. Time of Flight in Perspective: Instrumental and Computational Aspects of Time Resolution in Positron Emission Tomography. IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES 2021; 5:598-618. [PMID: 34553105 PMCID: PMC8454900 DOI: 10.1109/trpms.2021.3084539] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
The first time-of-flight positron emission tomography (TOF-PET) scanners were developed as early as in the 1980s. However, the poor light output and low detection efficiency of TOF-capable detectors available at the time limited any gain in image quality achieved with these TOF-PET scanners over the traditional non-TOF PET scanners. The discovery of LSO and other Lu-based scintillators revived interest in TOF-PET and led to the development of a second generation of scanners with high sensitivity and spatial resolution in the mid-2000s. The introduction of the silicon photomultiplier (SiPM) has recently yielded a third generation of TOF-PET systems with unprecedented imaging performance. Parallel to these instrumentation developments, much progress has been made in the development of image reconstruction algorithms that better utilize the additional information provided by TOF. Overall, the benefits range from a reduction in image variance (SNR increase), through allowing joint estimation of activity and attenuation, to better reconstructing data from limited angle systems. In this work, we review these developments, focusing on three broad areas: 1) timing theory and factors affecting the time resolution of a TOF-PET system; 2) utilization of TOF information for improved image reconstruction; and 3) quantification of the benefits of TOF compared to non-TOF PET. Finally, we offer a brief outlook on the TOF-PET developments anticipated in the short and longer term. Throughout this work, we aim to maintain a clinically driven perspective, treating TOF as one of multiple (and sometimes competitive) factors that can aid in the optimization of PET imaging performance.
Collapse
Affiliation(s)
- Dennis R Schaart
- Section Medical Physics & Technology, Radiation Science and Technology Department, Delft University of Technology, 2629 JB Delft, The Netherlands
| | - Georg Schramm
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU/UZ Leuven, 3000 Leuven, Belgium
| | - Johan Nuyts
- Department of Imaging and Pathology, Division of Nuclear Medicine, KU/UZ Leuven, 3000 Leuven, Belgium
| | - Suleman Surti
- Department of Radiology, University of Pennsylvania, Philadelphia, PA 19104 USA
| |
Collapse
|
32
|
Stockhoff M, Decuyper M, Van Holen R, Vandenberghe S. High-resolution monolithic LYSO detector with 6-layer depth-of-interaction for clinical PET. Phys Med Biol 2021; 66. [PMID: 34261049 DOI: 10.1088/1361-6560/ac1459] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2021] [Accepted: 07/14/2021] [Indexed: 01/23/2023]
Abstract
The system spatial resolution of whole-body positron emission tomography (PET) is limited to around 2 mm due to positron physics and the large diameter of the bore. To stay below this 'physics'-limit a scintillation detector with an intrinsic spatial resolution of around 1.3 mm is needed. Currently used detector technology consists of arrays of 2.6-5 mm segmented scintillator pixels which are the dominant factor contributing to the system resolution. Pixelated detectors using smaller pixels exist but face major drawbacks in sensitivity, timing, energy resolution and cost. Monolithic continuous detectors, where the spatial resolution is determined by the shape of the light distribution on the photodetector array, are a promising alternative. Without having the drawbacks of pixelated detectors, monolithic ones can also provide depth-of-interaction (DOI) information. In this work we present a monolithic detector design aiming to serve high-resolution clinical PET systems while maintaining high sensitivity. A 50 × 50 × 16 mm3Lutetium-Yttrium oxyorthosilicate scintillation crystal with silicon photomultiplier (SiPM) backside readout is calibrated in singles mode by a collimated beam obtaining a reference dataset for the event positioning. A mean nearest neighbour (MNN) algorithm and an artificial neural network for positioning are compared. The targeted intrinsic detector resolution of 1.3 mm needed to reach a 2 mm resolution on system level was accomplished with both algorithms. The neural network achieved a mean spatial resolution of 1.14 mm FWHM for the whole detector and 1.02 mm in the centre (30 × 30 mm2). The MNN algorithm performed slightly worse with 1.17 mm for the whole detector and 1.13 mm in the centre. The intrinsic DOI information will also result in uniform system spatial resolution over the full field of view.
Collapse
Affiliation(s)
- Mariele Stockhoff
- Department of Electronics and Information Systems, Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium
| | - Milan Decuyper
- Department of Electronics and Information Systems, Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium
| | - Roel Van Holen
- Department of Electronics and Information Systems, Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium
| | - Stefaan Vandenberghe
- Department of Electronics and Information Systems, Medical Image and Signal Processing (MEDISIP), Ghent University, Ghent, Belgium
| |
Collapse
|