1
|
Hossain MM, Konofagou EE. Feasibility of Phase Velocity Imaging Using Multi Frequency Oscillation-Shear Wave Elastography. IEEE Trans Biomed Eng 2024; 71:607-620. [PMID: 37647191 PMCID: PMC10873514 DOI: 10.1109/tbme.2023.3309996] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
OBJECTIVE To assess viscoelasticity, a pathologically relevant biomarker, shear wave elastography (SWE) generally uses phase velocity (PV) dispersion relationship generated via pulsed acoustic radiation force (ARF) excitation pulse. In this study, a multi-frequency oscillation (MFO)- excitation pulse with higher weight to higher frequencies is proposed to generate PV images via the generation of motion with energy concentrated at the target frequencies in contrast to the broadband frequency motion generated in pulsed SWE (PSWE). METHODS The feasibility of MFO-SWE to generate PV images at 100 to 1000 Hz in steps of 100 Hz was investigated by imaging 6 and 70 kPa inclusions with 6.5 and 10.4 mm diameter and ex vivo bovine liver with and without the presence of an aberration layer and chicken muscle ex vivo, and 4T1 mouse breast tumor, in vivo with comparisons to PSWE. RESULTS MFO-SWE-derived CNR was statistically higher than PSWE for 6 kPa (both with and without aberration) and 70 kPa (with aberration) inclusions and derived SNR of the liver was statistically higher than PSWE at higher frequency (600-1000 Hz). Quantitatively, at 600-1000 Hz, MFO-SWE improved CNR of inclusions (without and with) aberration on an average by (8.2 and 156)% and of the tumor by 122%, respectively, and improved SNR of the liver (without and with) aberration by (20.2 and 51.5)% and of chicken muscle by 72%, respectively compared to the PSWE. CONCLUSIONS AND SIGNIFICANCE These results indicate the advantages of MFO-SWE to improve PV estimation at higher frequencies which could improve viscoelasticity quantification and feature delineation.
Collapse
|
2
|
Cai C, Zheng X, Shi M, Bi J, Zhang Q. Bone collision detection method for robot assisted fracture reduction based on vibration excitation. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 229:107317. [PMID: 36563649 DOI: 10.1016/j.cmpb.2022.107317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Revised: 12/09/2022] [Accepted: 12/16/2022] [Indexed: 06/17/2023]
Abstract
BACKGROUND AND OBJECTIVE In the process of robotic fracture reduction, there is a risk of unintended collision of broken bones, which is not conducive to ensuring the safety of the reduction system. In order to solve this problem, this paper proposed a vibration-based collision detection method for fracture reduction process. METHODS Based on the two degree-of-freedom vibration response model, the factors affecting the respond of the vibration, including the excitation voltage, the clamping length at the proximal and distal ends, the mass and tensile force of the soft tissue, were obtained. The effects of these factors on the vibration transfer performance of broken bones and soft tissue were investigated by single factor experiments. RESULTS The results showed that, in terms of peak value, the increase of excitation voltage would make the vibration amplitude increase linearly, and the increase of soft tissue mass and tension increased the vibration transmission capacity of soft tissue in the frequency range of 500-1000 Hz. In terms of peak frequency, the clamping length at the distal end had the greatest influence, which reached 74 Hz, followed by 45 Hz at the proximal end. While the influence of other factors was little. According to single factor experiments, the excitation frequency in the verification experiments was determined as 677 Hz. Under the vibration interference with the acceleration amplitude of 1.2 G, this method achieved correct detection. CONCLUSION This research developed a broken bone collision detection method based on vibration excitation. The method can correctly detect the collision of broken bones with strong anti-interference ability. It is of great significance to improve the safety of fracture reduction process.
Collapse
Affiliation(s)
- Chenxu Cai
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Jinan 250061, China; National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, China
| | - Xuran Zheng
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Jinan 250061, China; National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, China
| | - Mingyang Shi
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Jinan 250061, China; National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, China
| | - Jianping Bi
- The Affiliated Hospital of Shandong University of Traditional Chinese Medicine, China
| | - Qinhe Zhang
- Key Laboratory of High Efficiency and Clean Mechanical Manufacture (Ministry of Education), School of Mechanical Engineering, Shandong University, Jinan 250061, China; National Demonstration Center for Experimental Mechanical Engineering Education, Shandong University, Jinan 250061, China.
| |
Collapse
|
3
|
Hossain MM, Konofagou EE. Imaging of Single Transducer-Harmonic Motion Imaging-Derived Displacements at Several Oscillation Frequencies Simultaneously. IEEE TRANSACTIONS ON MEDICAL IMAGING 2022; 41:3099-3115. [PMID: 35635828 PMCID: PMC9865352 DOI: 10.1109/tmi.2022.3178897] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Mapping of mechanical properties, dependent on the frequency of motion, is relevant in diagnosis, monitoring treatment response, or intra-operative surgical resection planning. While shear wave speeds at different frequencies have been described elsewhere, the effect of frequency on the "on-axis" acoustic radiation force (ARF)-induced displacement has not been previously investigated. Instead of generating single transducer-harmonic motion imaging (ST-HMI)-derived peak-to-peak displacement (P2PD) image at a particular frequency, a novel multi-frequency excitation pulse is proposed to generate P2PD images at 100-1000 Hz simultaneously. The performance of the proposed excitation pulse is compared with the ARFI by imaging 16 different inclusions (Young's moduli of 6, 9, 36, 70 kPa and diameters of 1.6, 2.5, 6.5, and 10.4 mm) embedded in an 18 kPa background. Depending on inclusion size and stiffness, the maximum CNR and contrast were achieved at different frequencies and were always higher than ARFI. The frequency, at which maximum CNR and contrast were achieved, increased with stiffness for fixed inclusion's size and decreased with size for fixed stiffness. In vivo feasibility is tested by imaging a 4T1 breast cancer mouse tumor on Day 6, 12, and 19 post-injection of tumor cells. Similar to phantoms, the CNR of ST-HMI images was higher than ARFI and increased with frequency for the tumor on Day 6. Besides, P2PD at 100-1000 Hz indicated that the tumor became stiffer with respect to the neighboring non-cancerous tissue over time. These results indicate the importance of using a multi-frequency excitation pulse to simultaneously generate displacement at multiple frequencies to better delineate inclusions or tumors.
Collapse
|
4
|
Sadeghi S, Lin CY, Cortes DH. Narrowband Shear Wave Generation Using Sinusoidally Modulated Acoustic Radiation Force. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2019; 66:264-272. [PMID: 30530360 DOI: 10.1109/tuffc.2018.2884847] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Most transient ultrasound elastography methods use high-intensity ultrasound "push" pulses that generate a shear wave with a wide frequency spectrum. However, it is difficult to control how the energy of the wave is distributed within that spectrum. For this reason, the shear-wave group velocity may not match that of harmonic methods like magnetic resonance elastography (MRE). The objective of this study was to introduce a narrowband shear wave generation method produced by "push" pulses with sinusoidally modulated intensity. The method, named harmonic shear wave imaging (HSWI), successively transmits a series of push pulses with a periodic change in duration. The excited shear waves form a continuous shear wave with a known main frequency that can be controlled by the user. Push pulses are interleaved with imaging pulses so only one clinical transducer is used to generate and record the shear waves. The proposed method was compared to MRE and a transient shear wave elastography method using phantoms and in vivo measurements. It was found that HSWI produces narrowband waves with a speed that closely matches that measured by MRE. Measurement of the acoustic output parameters indicated that the acoustic intensities in HSWI are suitable for clinical applications. The ability of HSWI to generate narrowband shear waves using a single linear array transducer makes it amenable for clinical translation. HSWI can potentially use the same thresholds as MRE for diagnosis of diseases affecting the stiffness of soft tissues.
Collapse
|
5
|
Urban MW. Production of acoustic radiation force using ultrasound: methods and applications. Expert Rev Med Devices 2018; 15:819-834. [PMID: 30350736 DOI: 10.1080/17434440.2018.1538782] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
INTRODUCTION Acoustic radiation force (ARF) is used in many biomedical applications. The transfer of momentum in acoustic waves can be used in a multitude of ways to perturb tissue and manipulate cells. AREAS COVERED This review will briefly cover the acoustic theory related to ARF, particularly that related to application in tissues. The use of ARF in measurement of mechanical properties will be treated in detail with emphasis on the spatial and temporal modulation of the ARF. Additional topics covered will be the manipulation of particles with ARF, correction of phase aberration with ARF, modulation of cellular behavior with ARF, and bioeffects related to ARF use. EXPERT COMMENTARY The use of ARF can be tailored to specific applications for measurements of mechanical properties or correction of focusing for ultrasound beams. Additionally, noncontact manipulation of particles and cells with ARF enables a wide array of applications for tissue engineering and biosensing.
Collapse
Affiliation(s)
- Matthew W Urban
- a Department of Radiology , Mayo Clinic , Rochester , MN , USA
| |
Collapse
|
6
|
Zhang X, Yin Y, Guo Y, Fan N, Lin H, Liu F, Diao X, Dong C, Chen X, Wang T, Chen S. Measurement of quantitative viscoelasticity of bovine corneas based on lamb wave dispersion properties. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:1461-72. [PMID: 25638310 DOI: 10.1016/j.ultrasmedbio.2014.12.017] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2014] [Revised: 12/11/2014] [Accepted: 12/15/2014] [Indexed: 05/04/2023]
Abstract
The viscoelastic properties of the human cornea can provide valuable information for clinical applications such as the early detection of corneal diseases, better management of corneal surgery and treatment and more accurate measurement of intra-ocular pressure. However, few techniques are capable of quantitatively and non-destructively assessing corneal biomechanics in vivo. The cornea can be regarded as a thin plate in which the vibration induced by an external vibrator propagates as a Lamb wave, the properties of which depend on the thickness and biomechanics of the tissue. In this study, pulses of ultrasound radiation force with a repetition frequency of 100 or 200 Hz were applied to the apex of corneas, and the linear-array transducer of a SonixRP system was used to track the tissue motion in the radial direction. Shear elasticity and viscosity were estimated from the phase velocities of the A0 Lamb waves. To assess the effectiveness of the method, some of the corneas were subjected to collagen cross-linking treatment, and the changes in mechanical properties were validated with a tensile test. The results indicated that the shear modulus was 137 ± 37 kPa and the shear viscosity was 3.01 ± 2.45 mPa · s for the group of untreated corneas and 1145 ± 267 kPa and was 0.16 ± 0.11 mPa · s for the treated group, respectively, implying a significant increase in elasticity and a significant decrease in viscosity after collagen cross-linking treatment. This result is in agreement with the results of the mechanical tensile test and with reports in the literature. This initial investigation illustrated the ability of this ultrasound-based method, which uses the velocity dispersion of low-frequency A0 Lamb waves, to quantitatively assess both the elasticity and viscosity of corneas. Future studies could discover ways to optimize this system and to determine the feasibility of using this method in clinical situations.
Collapse
Affiliation(s)
- Xinyu Zhang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Yin Yin
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Yanrong Guo
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Ning Fan
- Shenzhen Key Laboratory of Ophthalmology, Shenzhen Eye Hospital, Jinan University, Shenzhen, People's Republic of China
| | - Haoming Lin
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Fulong Liu
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Xianfen Diao
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Changfeng Dong
- Department of Ultrasonography, Third People's Hospital of Shenzhen, Shenzhen, People's Republic of China
| | - Xin Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China.
| | - Tianfu Wang
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| | - Siping Chen
- National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, School of Medicine, Shenzhen University, Shenzhen, People's Republic of China
| |
Collapse
|